Abstract
Purpose: To compare a novel oscillating-rotating (O-R) electric rechargeable toothbrush with micro-vibrations (Oral-B iO) to a manual brush for gingivitis and plaque reduction. Methods: Adult subjects with gingivitis and plaque were randomized to use either the O-R or the manual toothbrush with standard fluoride dentifrice twice daily. Efficacy was assessed at baseline, week 1, and week 8 using the Rustogi Modification of the Navy Plaque Index (RMNPI), Modified Gingival Index (MGI), and Gingival Bleeding Index (GBI). Gingivitis status (‘healthy’/‘not healthy’) was also assessed, per the American Academy of Periodontology/European Federation of Periodontology criteria. Results: One hundred and ten subjects were enrolled and completed the randomized controlled trial. The baseline mean number (SD) of bleeding sites for all subjects was 32.11 (16.703). At week 8, 82% of subjects using the O-R toothbrush were categorized as ‘healthy’ (<10% bleeding sites), versus 24% of subjects using the manual brush (P < 0.001). Subjects using the O-R toothbrush showed statistically significantly greater reductions (P < 0.001) in the number of bleeding sites, GBI scores and MGI scores versus those using a manual toothbrush as early as 1 week and throughout the 8-week study. The O-R toothbrush also provided statistically significantly greater reductions (P < 0.001) in all plaque measures, including sub-regions, versus the manual toothbrush after a single brushing and at weeks 1 and 8. Conclusions: The novel O-R electric toothbrush with micro-vibrations provided statistically significantly greater plaque and gingivitis reductions versus a manual toothbrush, with performance benefits demonstrated after a single brushing and continuing throughout the 8-week study.
Key words: Dental plaque, gingivitis, manual, micro-vibrations, oscillating-rotating, toothbrush
INTRODUCTION
Periodontal disease is highly prevalent in the United States, with up to 90% of adults reported to have gingivitis and nearly 50% of adults estimated to have periodontitis1, 2, 3. The development of periodontal disease is initiated through a host immune response to the oral bacteria present in dental plaque4, 5. The plaque-host interaction can be mediated by daily plaque control through at-home dental hygiene6.
Clinical evidence has shown that electric (i.e. power) toothbrushes are superior to manual toothbrushes for gingivitis reduction and plaque removal7, 8, 9, 10. These findings are corroborated by a recent long-term observational study which found consumers using an electric toothbrush retained 20% more teeth over an 11-year period than manual toothbrush users11. Two major categories of electric toothbrushes currently available are oscillating-rotating (O-R) and sonic, and direct comparisons have shown that O-R brushes provide greater gingivitis reduction and plaque removal benefits over sonic brushes9, 12, 13, 14, 15, 16.
Recently, a novel O-R toothbrush has been developed that incorporates micro-vibrations to represent the next generation in O-R toothbrushes (Oral-B iO). The novel brush design uses a linear magnetic drive, allowing energy to be directed to the bristles as an effective site for plaque removal. A by-product of the novel design is a quieter sound than previous models of O-R toothbrushes, which may be preferred by a subset of consumers because sound can be polarizing17. This clinical trial was conducted to evaluate and compare this novel O-R electric brush to a standard manual brush for gingivitis and plaque reduction over 8 weeks in adults with evidence of gingivitis and plaque accumulation.
METHODS
Study objective
The objective of this randomized, examiner-blind, parallel-group study was to compare the efficacy of a novel O-R electric rechargeable toothbrush with a round brush head to that of a standard soft manual toothbrush for reduction of gingivitis and plaque over an 8-week period in adult subjects with evidence of gingivitis and plaque at baseline. The study was conducted in compliance with the Declaration of Helsinki and the International Conference on Harmonization’s Good Clinical Practice Consolidated Guidelines and was registered with clinicaltrials.gov (NCT# NCT03624647). Institutional review and approval were obtained for the study protocol and informed consent form (Veritas IRB; approval number 16257). All participants provided written informed consent.
Assessments and outcomes
The Modified Gingival Index (MGI) and the Gingival Bleeding Index (GBI) were used to measure gingivitis16, 18, 19. Rustogi Modification of the Navy Plaque Index (RMNPI) was employed to measure plaque on up to 28 teeth (excluding third molars, crowns, and surfaces with cervical restorations)16, 20.
Investigational products
Subjects received either the O-R electric rechargeable toothbrush with micro-vibrations and round brush head (Oral-B iO with Ultimate Clean brush head, M7/OC15; Procter & Gamble, Cincinnati, OH) or a soft ADA manual toothbrush (Chicago, IL). All subjects received standard Crest Cavity Protection dentifrice with 0.243% sodium fluoride (0.15% w/v fluoride ion; Procter & Gamble).
Eligibility criteria
All Sum Research Center Ltd. (Mississauga, Ontario, Canada) recruited subjects between July and September 2019. Eligibility was limited to generally healthy adults 18 years of age or older who typically use a manual toothbrush as part of their at-home, usual dental hygiene regimen. Subjects must have had at least 16 natural teeth with facial and lingual scorable surfaces, a baseline pre-brushing MGI score of at least 1.75, a baseline pre-brushing RMNPI score of >0.5, and a baseline pre-brushing number of bleeding sites (sites with a GBI score of 1 or 2) of at least 20. Exclusion criteria included the need for antibiotic treatment prior to dental treatment; severe periodontal disease; active treatment for periodontitis, cancer, or a seizure disorder; teeth that were grossly carious, fully crowned, or extensively restored; use of antibiotics or chlorhexidine mouth rinse in the 2 weeks prior to baseline; fixed facial orthodontic appliances or removable partial dentures; peri/oral piercings; pacemaker or other implanted devices; or history of oral or periodontal surgery in the 2 months prior to baseline. During the study period, enrolled subjects were required to refrain from antibiotic treatment, use of chlorhexidine mouth rinse, use of any non-study oral hygiene products, and dental prophylaxis or any elective dentistry.
Study design
This was an 8-week, randomized, single-center, examiner-blind, parallel-group clinical trial with study visits at baseline, week 1, and week 8. Before the baseline visit, subjects were instructed to perform their typical oral hygiene routine with two stipulations. First, at least 12 hours were to elapse between the evening oral hygiene routine on the day before the baseline visit and the at-home morning brushing on the day of the baseline visit. Second, subjects were instructed to abstain from performing oral hygiene, eating, drinking, chewing gum, or using tobacco for 3–6 hours prior to coming to the clinic. Small sips of water were allowed up until 45 minutes prior to the visit.
During the study visit, subjects gave informed consent, followed by a review of their medical history, demographic information, and study inclusion/exclusion criteria. Subjects received a pre-brushing oral soft tissue assessment and MGI and GBI evaluations by an experienced examiner12, 16, 21, 22. After the gingival assessments were completed, plaque was disclosed using Chrom-O-Red erythrosine FD&C red 3 disclosing solution (Germiphene Corp., Bradford, Ontario, Canada) according to the manufacturer’s instructions. A RMNPI plaque assessment was conducted by the experienced examiner12, 16, 21, 22.
Qualifying subjects were stratified based on average MGI score (≤2.1 vs. >2.1), whole-mouth mean RMNPI (≤0.62 vs. >0.62), average number of total bleeding sites (≤28.0 vs. >28.0), and tobacco use (present or absent). Subject randomization was 1:1 according to a computer-generated schedule the study sponsor provided; participants were assigned approximately equally to each treatment group within each of the specified strata. The randomization process and the distribution of test products were conducted by site personnel in a protected area that ensured blinding of the examiner.
After randomization, subjects received a kit box containing their assigned toothbrush (novel O-R electric toothbrush or a soft manual toothbrush) and standard sodium fluoride dentifrice. Subjects were given supervised oral hygiene instructions and product usage instructions. Assigned products were to be used twice per day for approximately 8 weeks. Subjects brushed according to the provided usage instructions (manufacturer’s instructions for the O-R electric toothbrush and customary manner for the manual toothbrush) with their assigned toothbrush and toothpaste without observation in front of a mirror. After subjects completed brushing, the plaque disclosing procedure described above was conducted and a post-brushing RMNPI plaque assessment was performed by the experienced examiner.
The week 1 visit was conducted 7 ± 2 days from the baseline visit at approximately the same time as the baseline visit. Subjects refrained from brushing their teeth for 12 hours prior to their morning brushing at week 1. Subjects were to refrain from performing oral hygiene, eating, drinking, chewing gum, or using tobacco for 3–6 hours prior to the afternoon visit. Small sips of water were permitted until 45 minutes prior to the appointment. At the visit, continuance criteria were assessed and recorded. Subjects then received pre-brushing OST, MGI, and GBI assessments, in that order, by the experienced examiner. Next, the plaque disclosing procedure described above was conducted, and a pre-brushing RMNPI plaque assessment was performed by the experienced examiner.
Subjects refrained from brushing their teeth for 12 hours prior to their at-home morning brushing at week 8. The week 8 visit was conducted at approximately the same time as the baseline and week 1 afternoon visits. Subjects were also instructed to abstain from performing oral hygiene, eating, drinking, chewing gum, or using tobacco for 3–6 hours prior to the week 8 visit. Small sips of water were allowed up until 45 minutes prior to the visit. Subjects returned to the site and brought their test products. Continuance criteria were assessed and recorded. Subjects then received an oral soft tissue examination and MGI and GBI assessments, in that order, by the experienced examiner. Next, the plaque disclosing procedure described above was conducted, and an RMNPI plaque assessment was performed by the experienced examiner. Finally, subjects returned their assigned toothbrush and toothpaste.
Safety
Safety was assessed at each study visit. Safety event data were based on subject self-report. All serious adverse events (AEs) and all oral-related AEs were recorded, as were any non-serious, voluntarily reported whole body AEs that had the potential to be product related.
Statistical analysis
Power analyses were conducted with α = 0.05, using a 2-sided test and a sample size of 55 subjects per group. Assuming the variability of whole-mouth MGI is 0.092, a sample size of 55 subjects per group was to provide 90% power to detect a difference in MGI mean scores of 0.058 units between treatments. Assuming the variability in number of bleeding sites is 3.49, a sample size of 55 subjects per group was to provide at least 90% power to detect a difference in number of bleeding sites of at least 2.18 units between treatments. Similarly, for plaque, assuming the variability of whole-mouth RMNPI is 0.041, a sample size of 55 subjects per group was to provide at least 90% power to detect a difference in RMNPI mean scores of 0.026 units between treatments.
Demographic and baseline variables were summarized by treatment group, and adverse events reported or noted during the study were documented.
The percentage of subjects whose gingivitis status was classified as ‘not healthy’ per the American Academy of Periodontology (AAP) and the European Federation of Periodontology (EFP) criteria23 (e.g. ≥10% bleeding sites or at least 15 bleeding sites for 150 gradable sites) at each visit was computed and compared between treatment groups using a chi-square test. A logistic regression analysis was carried out on the week 8 bleeding data to compute the odds ratio of transitioning from ‘not healthy’ (≥10% bleeding sites) to ‘generally healthy’ (<10% bleeding sites).
Statistical analyses for gingivitis efficacy were based on change from baseline scores for whole-mouth average MGI, GBI, and number of bleeding sites (baseline minus week 1 and baseline minus week 8). The within-treatment difference from baseline gingivitis scores (MGI, GBI, number of bleeding sites) was tested versus zero using an ANCOVA model with the respective baseline score as the covariate. ANCOVA was also performed separately by week to determine treatment differences on the whole-mouth average gingivitis reduction with the respective baseline gingivitis score as the covariate.
Whole-mouth, single-brushing plaque reductions from the baseline visit (pre-brushing minus post-brushing) were analyzed for treatment differences using an ANCOVA with the whole-mouth, pre-brushing RMNPI score as the covariate. Similar analyses were carried out for gingival margin and proximal RMNPI scores. Whole-mouth, multiple-brushing plaque reduction analyses were based on the average whole-mouth, pre-brushing RMNPI change from baseline score at each post-baseline visit (baseline pre-brushing minus week post score). Plaque reductions at week 1 and week 8 were analyzed for treatment differences using an ANCOVA with the baseline whole-mouth, pre-brushing RMNPI score as the covariate. Similar analyses were carried out for gingival margin and proximal RMNPI scores. The lingual surfaces of the gingivitis and plaque endpoints were analyzed separately for treatment differences as described above.
To assess the consistency of plaque removal between buccal and lingual surfaces during a single-brushing session, an analysis of the whole-mouth RMNPI lingual minus buccal difference score was carried out for the single-brushing plaque endpoint.
All treatment comparisons were two-sided tests with an α = 0.05 significance level. Multiple comparison adjustments were not carried out.
RESULTS
Study population
One hundred and ten subjects (77 females and 33 males) were enrolled. All of the enrolled subjects were randomized and completed the study. The mean (SD) age was 47.2 (14.3) years. Demographic characteristics are shown in Table 1.
Table 1.
Demographic characteristic | Manual toothbrush ( n = 55) |
Novel O-R electric toothbrush ( n = 55) |
Overall (n = 110) |
P-value |
---|---|---|---|---|
Age (y) | ||||
Mean (SD) | 48.3 (15.8) | 46.1 (12.8) | 47.2 (14.3) | 0.415 |
Min.–Max. | 19–83 | 18–69 | 18–83 | |
Ethnicity | ||||
Hispanic or Latino | 2 (4%) | 2 (4%) | 4 (4%) | 1.000 |
Not Hispanic or Latino | 53 (96%) | 53 (96%) | 106 (96%) | |
Race | ||||
Asian | 7 (13%) | 9 (16%) | 16 (15%) | 0.301 |
Black or African American | 14 (25%) | 15 (27%) | 29 (26%) | |
Multi-Racial | 0 (0%) | 4 (7%) | 4 (4%) | |
Native Hawaiian or other Pacific Islander | 2 (4%) | 2 (4%) | 4 (4%) | |
White/Caucasian | 32 (58%) | 25 (45%) | 57 (52%) | |
Sex | ||||
Female | 40 (73%) | 37 (67%) | 77 (70%) | 0.533 |
Male | 15 (27%) | 18 (33%) | 33 (30%) |
Gingival health status
At baseline, all subjects had a gingivitis status classified as ‘not healthy’ according to the AAP/EFP guidelines23 (e.g. ≥10% bleeding sites or at least 15 bleeding sites for 150 gradable sites). At week 1, the novel O-R electric brush group had a significantly higher number of ‘healthy’ subjects than the manual brush group (16.4% vs. 1.8%, P = 0.008) (Table 2). This difference was pronounced at week 8 (81.8% vs. 23.6%; P < 0.001). A logistic regression analysis found that the odds of transitioning from ‘not healthy’ (≥10% bleeding sites) at baseline to ‘healthy’ (<10% bleeding sites) gingivitis status at week 8 was 14.5 times higher when using the electric brush than when using the manual brush.
Table 2.
‘Not healthy’ n (%) |
‘Healthy’ n (%) |
P-value (manual brush vs. novel O-R electric brush) | |
---|---|---|---|
Week 1 | |||
Manual brush | 54 (98.2%) | 1 (1.8%) | 0.008 |
Novel O-R electric brush | 46 (83.6%) | 9 (16.4%) | |
Week 8 | |||
Manual brush | 42 (76.4%) | 13 (23.6%) | <0.001 |
Novel O-R electric brush | 10 (18.2%) | 45 (81.8%) |
Whole-Mouth gingivitis reduction efficacy
At baseline, the mean number of bleeding sites, mean GBI score, and whole-mouth mean MGI score did not differ significantly (P ≥ 0.219) between the treatment groups (Table 3). Both toothbrush groups showed significant improvements from baseline on all three measures at both week 1 and week 8 (P < 0.002). Between-group comparisons were statistically significant for all 3 measures, favoring the electric brush group, as early as week 1 and sustained at week 8 (P < 0.001 for all). The electric brush group showed statistically significantly greater adjusted mean changes from baseline at week 8 compared to the manual group for MGI (0.356 vs. 0.121), GBI (0.144 vs. 0.048), and mean number of bleeding sites (19.257 vs. 6.662).
Table 3.
Baseline (SD)* | Adjusted mean (SE) change from baseline† | Ratio vs. manual brush‡ | 2-Sided P-value | |
---|---|---|---|---|
MGI Score | ||||
Week 1 | ||||
Manual brush | 2.159 (0.124) | 0.024 (0.007) | – | <0.001 |
Novel O-R electric brush | 2.136 (0.111) | 0.089 (0.011) | 3.71 | |
Week 8 | ||||
Manual brush | 2.159 (0.124) | 0.121 (0.012) | – | <0.001 |
Novel O-R electric brush | 2.136 (0.111) | 0.356 (0.019) | 2.94 | |
GBI score | ||||
Week 1 | ||||
Manual brush | 0.246 (0.175) | 0.010 (0.003) | – | <0.001 |
Novel O-R electric brush | 0.213 (0.123) | 0.030 (0.003) | 3.00 | |
Week 8 | ||||
Manual brush | 0.246 (0.175) | 0.048 (0.004) | – | <0.001 |
Novel O-R electric brush | 0.213 (0.123) | 0.144 (0.007) | 3.00 | |
Number of bleeding sites | ||||
Week 1 | ||||
Manual brush | 34.073 (18.746) | 1.356 (0.398) | – | <0.001 |
Novel O-R electric brush | 30.145 (14.280) | 3.607 (0.330) | 2.66 | |
Week 8 | ||||
Manual brush | 34.073 (18.746) | 6.662 (0.592) | – | <0.001 |
Novel O-R electric brush | 30.145 (14.280) | 19.257 (0.673) | 2.89 |
Baseline gingivitis measures did not differ significantly (P ≥ 0.219) between treatment groups.
Reductions versus baseline were statistically significant at all time points for all measures for the manual brush (P < 0.002) and electric brush (P < 0.001).
Ratio = novel electric brush/manual brush.
Lingual and molar gingivitis reduction efficacy
The baseline mean MGI and GBI scores on the lingual surfaces were not significantly different between treatment groups, but there was a significant difference between the treatment groups in the baseline mean number of bleeding sites on the lingual surfaces with the manual brush group having more lingual bleeding sites than the electric brush group (23.4 vs. 18.9; P = 0.022). Both brush groups had significant improvements from baseline at week 1 and week 8 for all three gingivitis measurements on the lingual surfaces, with P ≤ 0.011 on all measurements for the manual brush group and P < 0.001 on all measurements for the electric brush group. For the between-group comparisons, there were significant differences seen at both week 1 (P ≤ 0.037 for all) and week 8 (P < 0.001 for all) favoring the electric brush group for all lingual gingivitis measures.
In the molar regions, the baseline mean MGI score, mean GBI score, and mean number of bleeding sites did not differ significantly between the treatment groups (Table 4). At week 1, the electric brush group had significant improvements from baseline for all measures in the molar region (P < 0.014) while the manual brush group did not (P ≥ 0.314). However, at week 8, both toothbrush groups showed significant improvements from baseline for all three measurements in the molar region (P < 0.001). For the between-group comparisons, the electric brush group showed significantly greater gingivitis reductions in the molar measurements than the manual group (Table 4) at week 1 (P < 0.049 for all) and week 8 (P < 0.001 for all).
Table 4.
Baseline (SD)* | Adjusted mean (SE) change from baseline† | Ratio vs. manual brush‡ | 2-Sided P-value | |
---|---|---|---|---|
MGI | ||||
Week 1 | ||||
Manual brush | 2.251 (0.150) | 0.002 (0.016) | – | 0.048 |
Novel O-R electric brush | 2.242 (0.179) | 0.047 (0.016) | 23.50 | |
Week 8 | ||||
Manual brush | 2.251 (0.150) | 0.072 (0.013) | – | <0.001 |
Novel O-R brush | 2.242 (0.179) | 0.223 (0.024) | 3.10 | |
GBI | ||||
Week 1 | ||||
Manual brush | 0.358 (0.182) | 0.002 (0.004) | – | 0.001 |
Novel O-R electric brush | 0.355 (0.181) | 0.023 (0.005) | 11.50 | |
Week 8 | ||||
Manual Brush | 0.358 (0.182) | 0.029 (0.006) | – | <0.001 |
Novel O-R electric brush | 0.355 (0.181) | 0.189 (0.012) | 6.52 | |
Number of bleeding sites | ||||
Week 1 | ||||
Manual brush | 13.273 (6.193) | 0.121 (0.141) | – | 0.002 |
Novel O-R electric brush | 12.018 (4.844) | 0.732 (0.130) | 6.05 | |
Week 8 | ||||
Manual brush | 13.273 (6.193) | 1.008 (0.243) | – | <0.001 |
Novel O-R electric brush | 12.018 (4.844) | 6.133 (0.423) | 6.08 |
Baseline gingivitis measures in the molar region did not differ significantly (P ≥ 0.239) between treatment groups.
Reductions versus baseline were statistically significant in all regions only at week 8 for the manual brush (P < 0.001) and at both weeks 1 (P < 0.014) and 8 (P < 0.001) for the electric brush.
Ratio = novel electric brush group/manual brush.
Plaque reduction efficacy with a single brushing
The whole-mouth mean RMNPI scores were not significantly different between treatment groups at baseline (Table 5), nor were the proximal or gingival margin mean RMNPI scores (P ≥ 0.608 for all). As shown in Table 5, after a single brushing at the baseline visit, the electric brush group had significantly greater adjusted mean plaque removal in the whole mouth (0.474 vs. 0.332), in the proximal regions (0.822 vs. 0.591), and along the gingival margin (0.697 vs. 0.461) compared to the manual brush group (P < 0.001 for all). Similar results were seen for whole-mouth, proximal, and gingival margin mean RMNPI scores on the lingual surfaces and in the molar regions (Table 5).
Table 5.
Baseline (SD)* | Adjusted mean (SE) change from pre-brushing baseline | Ratio vs. manual brush† | 2-Sided P-value | |
---|---|---|---|---|
Whole mouth | ||||
Manual brush | 0.616 (0.035) | 0.332 (0.010) | – | <0.001 |
Novel O-R electric brush | 0.620 (0.044) | 0.474 (0.008) | 1.43 | |
Whole-mouth proximal | ||||
Manual brush | 1.000 (0.000) | 0.591 (0.017) | – | <0.001 |
Novel O-R electric brush | 1.000 (0.000) | 0.822 (0.013) | 1.39 | |
Whole-mouth gingival margin | ||||
Manual brush | 1.000 (0.000) | 0.461 (0.017) | – | <0.001 |
Novel O-R electric brush | 1.000 (0.000) | 0.697 (0.016) | 1.51 | |
Lingual surfaces | ||||
Whole mouth | ||||
Manual brush | 0.620 (0.036) | 0.226 (0.015) | – | <0.001 |
Novel O-R electric brush | 0.618 (0.040) | 0.421 (0.011) | 1.86 | |
Proximal | ||||
Manual brush | 1.000 (0.000) | 0.435 (0.027) | – | <0.001 |
Novel O-R electric brush | 1.000 (0.000) | 0.763 (0.018) | 1.75 | |
Gingival margin | ||||
Manual brush | 1.000 (0.000) | 0.267 (0.024) | – | <0.001 |
Novel O-R electric brush | 1.000 (0.000) | 0.589 (0.020) | 2.21 | |
Molar surfaces | ||||
Whole mouth | ||||
Manual brush | 0.648 (0.043) | 0.163 (0.012) | – | <0.001 |
Novel O-R electric brush | 0.651 (0.047) | 0.311 (0.016) | 1.91 | |
Proximal | ||||
Manual brush | 1.000 (0.000) | 0.232 (0.026) | – | <0.001 |
Novel O-R electric brush | 1.000 (0.000) | 0.520 (0.033) | 2.24 | |
Gingival margin | ||||
Manual brush | 1.000 (0.000) | 0.127 (0.017) | – | <0.001 |
Novel O-R electric brush | 1.000 (0.000) | 0.331 (0.031) | 2.61 |
Baseline plaque measures did not differ significantly (P ≥ 0.608) between treatment groups.
Ratio = novel electric O-R brush/manual brush.
Plaque reduction efficacy at week 1 and week 8
When assessing treatments after only 1 week of brushing, the electric brush was found to have significantly greater plaque removal in the whole mouth (0.104 vs. 0.046), in the proximal regions (0.185 vs. 0.071), and along the gingival margin (0.045 vs. 0.011) compared to the manual brush (P ≤ 0.002). Significantly greater plaque reduction benefits (P < 0.001) for the electric brush continued in all regions after 8 weeks. Similar results were seen for whole-mouth, proximal, and gingival margin mean RMNPI scores on the lingual surfaces and in the molar regions at weeks 1 and 8 (Table 6).
Table 6.
Baseline (SD)* | Week 1 |
Week 8 |
|||||
---|---|---|---|---|---|---|---|
Adjusted mean (SE) change from pre-brushing baseline | Ratio vs. manual brush† | 2-Sided P-value | Adjusted mean (SE) change from pre-brushing baseline | Ratio vs. manual brush† | 2-Sided P-value | ||
Whole mouth | |||||||
Manual brush | 0.616 (0.35) | 0.046 (0.005) | – | <0.001 | 0.060 (0.004) | – | |
Novel O-R electric brush | 0.620 (0.044) | 0.104 (0.008) | 2.26 | 0.152 (0.005) | 2.53 | <0.001 | |
Whole-mouth proximal | |||||||
Manual brush | 1.000 (0.000) | 0.071 (0.010) | – | <0.001 | 0.114 (0.013) | – | |
Novel O-R electric brush | 1.000 (0.000) | 0.185 (0.021) | 2.61 | 0.364 (0.023) | 3.19 | <0.001 | |
Whole-mouth gingival margin | |||||||
Manual brush | 1.000 (0.000) | 0.011 (0.002) | – | 0.002 | 0.008 (0.002) | – | |
Novel O-R electric brush | 1.000 (0.000) | 0.045 (0.010) | 4.09 | 0.050 (0.005) | 6.25 | <0.001 | |
Lingual surfaces | |||||||
Whole mouth | |||||||
Manual brush | 0.620 (0.036) | 0.022 (0.006) | – | <0.001 | 0.049 (0.004) | – | |
Novel O-R electric brush | 0.618 (0.040) | 0.072 (0.007) | 3.27 | 0.129 (0.007) | 2.63 | <0.001 | |
Proximal | |||||||
Manual brush | 1.000 (0.000) | 0.024 (0.008) | – | <0.0001 | 0.081 (0.014) | – | |
Novel O-R electric brush | 1.000 (0.000) | 0.112 (0.019) | 4.67 | 0.306 (0.027) | 3.78 | <0.001 | |
Gingival margin | |||||||
Manual brush | 1.000 (0.000) | 0.004 (0.002) | – | 0.017 | 0.003 (0.002) | – | |
Novel O-R electric brush | 1.000 (0.000) | 0.019 (0.006) | 4.75 | 0.034 (0.005) | 11.33 | <0.001 | |
Molar surfaces | |||||||
Whole mouth | |||||||
Manual brush | 0.648 (0.043) | 0.039 (0.004) | -- | <0.001 | 0.052 (0.004) | – | |
Novel O-R electric brush | 0.651 (0.047) | 0.077 (0.006) | 1.97 | 0.099 (0.005) | 1.90 | <0.001 | |
Proximal | |||||||
Manual brush | 1.000 (0.000) | 0.002 (0.002) | – | 0.005 | 0.022 (0.007) | – | |
Novel O-R electric brush | 1.000 (0.000) | 0.043 (0.014) | 21.5 | 0.112 (0.018) | 5.09 | <0.001 | |
Gingival margin | |||||||
Manual brush | 1.000 (0.000) | 0 | – | 0.031 | 0 | – | |
Novel O-R electric brush | 1.000 (0.000) | 0.010 (0.005) | >18 | 0.003 (0.001) | >18 | 0.004 |
Baseline plaque measures did not differ significantly (P > 0.320) between treatment groups.
Ratio = novel electric O-R brush/manual brush.
Safety
No adverse events were reported.
DISCUSSION
This randomized, examiner-blind, parallel-group study demonstrated that use of a novel O-R electric toothbrush with micro-vibrations and a round brush head produced improved reduction of gingivitis and plaque over an 8-week period in adult subjects with evidence of gingivitis and plaque at baseline when compared with use of standard manual toothbrush. Plaque reduction benefits were apparent after a single-brushing episode, with the electric brush group showing significantly greater plaque removal in the whole mouth (by 1.4 times), in the proximal regions (by 1.4 times), and along the gingival margin (by 1.5 times) than the manual brush group. During the 8-week trial, plaque removal efficacy with the O-R electric brush continued to increase, with significantly greater plaque removal compared to the manual brush by 2.5 times in the whole mouth, by 3.2 times in the proximal regions, and by 6.3 times along the gingival margin. For all whole-mouth gingivitis efficacy endpoints at week 8, the electric brush group had significantly greater gingivitis reduction (by approximately three times) compared to the manual brush group. Consistent with other research reported in this issue24, the O-R electric brush group showed an increase in brushing evenness as evidenced by superior benefits in hard-to-reach areas (e.g. lingual, molar regions). Both the O-R electric brush and the manual brush were well tolerated by subjects, with no adverse events.
The findings from this trial are consistent with earlier studies and meta-analyses involving thousands of subjects indicating greater plaque and gingivitis reduction benefits with an O-R electric brush compared with a manual brush7, 8, 9. A recent meta-analysis of sixteen Oral-B O-R electric toothbrush clinical trials, involving over 2,100 gingivitis subjects, showed that O-R electric toothbrushes provide statistically significant gingivitis reductions irrespective of the subject’s baseline disease level25. Collectively, these findings demonstrate benefits provided by O-R electric toothbrushes are generalizable to the representative population.
Although all subjects in this study had a baseline gingivitis status classified as ‘not healthy’23, by week 8 there were over three times as many subjects with a ‘healthy’ gingivitis status in the O-R electric brush group than in the manual brush group (81.8% vs. 23.6%). Improvement in gingival health is a highly relevant clinical finding. Long-standing bleeding on probing is associated with greater attachment loss and greater risk of tooth loss over time11, 26, 27. Furthermore, a number of studies have shown that even mild gingivitis can be associated with pain, discomfort, and difficulties performing oral hygiene28, 29, 30. Improvement in gingival health is thus associated with improvements in health-related quality of life31, 32.
As with all research, there are limitations to this study. While significant benefits were seen with the novel O-R electric brush versus the manual brush during this 8-week study, longer-term research would be useful to quantify benefits with further extended use. In addition, research among specific populations, such as studies done with earlier O-R models among orthodontic patients and implant patients33, 34, 35, would provide additional insights to the plaque removal efficacy and gingival health benefits of the toothbrush when compared to use of control brushes. Finally, the role of interactive features with use of the novel O-R electric toothbrush will be evaluated in future research to understand if they provide improvements in brushing behavior seen with other interactive O-R toothbrushes36, 37.
CONCLUSIONS
Use of a novel O-R electric toothbrush with micro-vibrations produced improved reduction of gingivitis and plaque over 8 weeks in adults with evidence of gingivitis and plaque at baseline when compared with use of standard manual toothbrush. Plaque reduction benefits were apparent after a single-brushing episode and continued to increase over time. For gingival endpoints, there were over three times as many subjects with healthy gingiva in the novel electric brush group than in the manual brush group at week 8. Gingivitis reduction benefits were particularly pronounced in the hard-to-reach lingual surfaces and molar regions. Further studies of the novel electric brush are warranted.
Acknowledgements
We thank Erinn Conde, BS, for her role in study execution and Jillian Lokere, MS, for medical writing assistance preparing this manuscript. Procter & Gamble, Cincinnati, OH, USA, funded this study and medical writing assistance.
Conflicts of interest
J.G. and R.A. are employees of The Procter & Gamble Company. C.R.G. and J.Q. report no conflicts of interest.
REFERENCES
- 1.Beydoun HA, Hossain S, Beydoun MA et al. Periodontal disease, sleep duration and white blood cell markers in the 2009–2014 national health and nutrition examination surveys. J Periodontol 2019 Sep 25. 10.1002/JPER.19-0055. [Epub ahead of print] [DOI] [PMC free article] [PubMed]
- 2.Eke PI, Dye BA, Wei L, et al. Update on prevalence of periodontitis in adults in the United States: NHANES 2009 to 2012. J Periodontol. 2015;86:611–622. doi: 10.1902/jop.2015.140520. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 3.Li Y, Lee S, Hujoel P, et al. Prevalence and severity of gingivitis in American adults. Am J Dent. 2010;23:9–13. [PubMed] [Google Scholar]
- 4.Mariotti A. Dental plaque-induced gingival diseases. Ann Periodontol. 1999;4:7–19. doi: 10.1902/annals.1999.4.1.7. [DOI] [PubMed] [Google Scholar]
- 5.Khan SA, Kong EF, Meiller TF, et al. Periodontal diseases: bug induced, host promoted. PLoS Pathog. 2015;11:e1004952. doi: 10.1371/journal.ppat.1004952. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 6.Loe H, Theilade E, Jensen SB. Experimental gingivitis in man. J Periodontol. 1965;36:177–187. doi: 10.1902/jop.1965.36.3.177. [DOI] [PubMed] [Google Scholar]
- 7.Yaacob M, Worthington HV, Deacon SA et al. Powered versus manual toothbrushing for oral health. Cochrane Database Syst Rev 2014 Cd002281. [DOI] [PMC free article] [PubMed]
- 8.Elkerbout TA, Slot DE, Rosema NAM, et al. How effective is a powered toothbrush as compared to a manual toothbrush? A systematic review and meta-analysis of single brushing exercises. Int J Dent Hyg. 2020;18:17–26. doi: 10.1111/idh.12401. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 9.Van der Weijden FA, Slot DE. Efficacy of homecare regimens for mechanical plaque removal in managing gingivitis a meta review. J Clin Periodontol. 2015;42(Suppl 16):S77–91. doi: 10.1111/jcpe.12359. [DOI] [PubMed] [Google Scholar]
- 10.de Jager M, Rmaile A, Darch O, et al. The effectiveness of manual versus high-frequency, high-amplitude sonic powered toothbrushes for oral health: a meta-analysis. J Clin Dent. 2017;28:A13–A28. [PubMed] [Google Scholar]
- 11.Pitchika V, Pink C, Völzke H, et al. Long-term impact of powered toothbrush on oral health: 11-year cohort study. J Clin Periodontol. 2019;46:713–722. doi: 10.1111/jcpe.13126. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 12.Goyal CR, Qaqish J, He T, et al. A randomized 12-week study to compare the gingivitis and plaque reduction benefits of a rotation-oscillation power toothbrush and a sonic power toothbrush. J Clin Dent. 2009;20:93–98. [PubMed] [Google Scholar]
- 13.Klukowska M, Grender JM, Goyal CR, et al. 12-week clinical evaluation of a rotation/oscillation power toothbrush versus a new sonic power toothbrush in reducing gingivitis and plaque. Am J Dent. 2012;25:287–292. [PubMed] [Google Scholar]
- 14.Klukowska M, Grender JM, Conde E, et al. A 12-week clinical comparison of an oscillating-rotating power brush versus a marketed sonic brush with self-adjusting technology in reducing plaque and gingivitis. J Clin Dent. 2013;24:55–61. [PubMed] [Google Scholar]
- 15.Ccahuana-Vasquez RA, Conde E, Grender JM, et al. An eight-week clinical evaluation of an oscillating-rotating power toothbrush with a brush head utilizing angled bristles compared with a sonic toothbrush in the reduction of gingivitis and plaque. J Clin Dent. 2015;26:80–85. [PubMed] [Google Scholar]
- 16.Ccahuana-Vasquez RA, Conde EL, Cunningham P, et al. An 8-week clinical comparison of an oscillating-rotating electric rechargeable toothbrush and a sonic toothbrush in the reduction of gingivitis and plaque. J Clin Dent. 2018;29:27–32. [PubMed] [Google Scholar]
- 17.Zampini M, Guest S, Spence C. The role of auditory cues in modulating the perception of electric toothbrushes. J Dent Res. 2003;82:929–932. doi: 10.1177/154405910308201116. [DOI] [PubMed] [Google Scholar]
- 18.Lobene RR, Weatherford T, Ross NM, et al. A modified gingival index for use in clinical trials. Clin Prev Dent. 1986;8:3–6. [PubMed] [Google Scholar]
- 19.Saxton CA, Van der Ouderaa FJ. The effect of a dentifrice containing zinc citrate and triclosan on developing gingivitis. J Periodontal Res. 1989;24:75–80. doi: 10.1111/j.1600-0765.1989.tb00860.x. [DOI] [PubMed] [Google Scholar]
- 20.Rustogi KN, Curtis JP, Volpe AR, et al. Refinement of the Modified Navy Plaque Index to increase plaque scoring efficiency in gumline and interproximal tooth areas. J Clin Dent. 1992;3:C9–12. [PubMed] [Google Scholar]
- 21.Goyal CR, Klukowska M, Grender JM, et al. Evaluation of a new multi-directional power toothbrush versus a marketed sonic toothbrush on plaque and gingivitis efficacy. Am J Dent. 2012;25:21A–26A. Spec Iss A. [PubMed] [Google Scholar]
- 22.Ccahuana-Vasquez RA, Adam R, Conde E, et al. A 5-week randomized clinical evaluation of a novel electric toothbrush head with regular and tapered bristles versus a manual toothbrush for reduction of gingivitis and plaque. Int J Dent Hyg. 2019;17:153–160. doi: 10.1111/idh.12372. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 23.Trombelli L, Farina R, Silva CO, et al. Plaque-induced gingivitis: Case definition and diagnostic considerations. J Periodontol. 2018;89(Suppl 1):S46–S73. doi: 10.1002/JPER.17-0576. [DOI] [PubMed] [Google Scholar]
- 24.Adam R, Erb J, Grender J. Randomized controlled trial assessing plaque removal of an oscillating-rotating electric toothbrush with micro-vibrations. Int Dent J. 2020;70(Suppl 1):S22–S27. doi: 10.1111/idj.12568. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 25.Grender J, Adam R, Zou Y. The effects of oscillating-rotating electric toothbrushes on plaque and gingival health: a meta-analysis. Am J Dent. 2020;33:3–11. [PubMed] [Google Scholar]
- 26.Schätzle M, Löe H, Burgin W, et al. Clinical course of chronic periodontitis. I. Role of gingivitis. J Clin Periodontol. 2003;30:887–901. doi: 10.1034/j.1600-051x.2003.00414.x. [DOI] [PubMed] [Google Scholar]
- 27.Schätzle M, Löe H, Lang NP, et al. The clinical course of chronic periodontitis. J Clin Periodontol. 2004;31:1122–1127. doi: 10.1111/j.1600-051X.2004.00634.x. [DOI] [PubMed] [Google Scholar]
- 28.Ferreira MC, Dias-Pereira AC, Branco-de-Almeida LS, et al. Impact of periodontal disease on quality of life: a systematic review. J Periodontal Res. 2017;52:651–665. doi: 10.1111/jre.12436. [DOI] [PubMed] [Google Scholar]
- 29.Buset SL, Walter C, Friedmann A, et al. Are periodontal diseases really silent? A systematic review of their effect on quality of life. J Clin Periodontol. 2016;43:333–344. doi: 10.1111/jcpe.12517. [DOI] [PubMed] [Google Scholar]
- 30.Ustaoglu G, Goller Bulut D, Gumus KC, et al. Evaluation of the effects of different forms of periodontal diseases on quality of life with OHIP-14 and SF-36 questionnaires: a cross-sectional study. Int J Dent Hyg. 2019;17:343–349. doi: 10.1111/idh.12409. [DOI] [PubMed] [Google Scholar]
- 31.Graziani F, Music L, Bozic D, et al. Is periodontitis and its treatment capable of changing the quality of life of a patient? Br Dent J. 2019;227:621–625. doi: 10.1038/s41415-019-0735-3. [DOI] [PubMed] [Google Scholar]
- 32.Mendez M, Melchiors Angst PD, Stadler AF, et al. Impacts of supragingival and subgingival periodontal treatments on oral health-related quality of life. Int J Dent Hyg. 2017;15:135–141. doi: 10.1111/idh.12193. [DOI] [PubMed] [Google Scholar]
- 33.Vandekerckhove B, Quirynen M, Warren PR, et al. The safety and efficacy of a powered toothbrush on soft tissues in patients with implant-supported fixed prostheses. Clin Oral Investig. 2004;8:206–210. doi: 10.1007/s00784-004-0278-z. [DOI] [PubMed] [Google Scholar]
- 34.Erbe C, Jacobs C, Klukowska M, et al. A randomized clinical trial to evaluate the plaque removal efficacy of an oscillating-rotating toothbrush versus a sonic toothbrush in orthodontic patients using digital imaging analysis of the anterior dentition. Angle Orthod. 2019;89:385–390. doi: 10.2319/080317-520.1. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 35.Erbe C, Klukowska M, Tsaknaki I, et al. Efficacy of 3 toothbrush treatments on plaque removal in orthodontic patients assessed with digital plaque imaging: a randomized controlled trial. Am J Orthod Dentofacial Orthop. 2013;143:760–766. doi: 10.1016/j.ajodo.2013.03.008. [DOI] [PubMed] [Google Scholar]
- 36.Erbe C, Klees V, Braunbeck F, et al. Comparative assessment of plaque removal and motivation between a manual toothbrush and an interactive power toothbrush in adolescents with fixed orthodontic appliances: a single-center, examiner-blind randomized controlled trial. Am J Orthod Dentofacial Orthop. 2019;155:462–472. doi: 10.1016/j.ajodo.2018.12.013. [DOI] [PubMed] [Google Scholar]
- 37.Erbe C, Klees V, Ferrari-Peron P, et al. A comparative assessment of plaque removal and toothbrushing compliance between a manual and an interactive power toothbrush among adolescents: a single-center, single-blind randomized controlled trial. BMC Oral Health. 2018;18:130. doi: 10.1186/s12903-018-0588-1. [DOI] [PMC free article] [PubMed] [Google Scholar]