In the published article, there was an error in Table 1 as published. The footnote does not correspond to the superscript in the table. The corrected Table 1 and its caption appear below.
TABLE 1.
Blood | Seminiferous tubule (SNT) | Rete testis | Efferent duct | Initial segment | Caput | Corpus | Cauda | Vas deferens | |
---|---|---|---|---|---|---|---|---|---|
Na+ | 138.65∼147.2 a , b , c | 109.5∼135.44 a , b | 130.8∼141.84 b , c , d | 144.2 c | 136.8 c | 101.8∼112.1 a , b , d | 57.9∼93.8 a , b | 20.6∼37.17 a , b , d | 23.3 a |
K+ | 4.9∼5.83 b , c | 39.77∼46.2 a , b | 12.4∼16.1 b , c , d | 5.7 c | 11.6 c | 16.0∼27.6 a , b , d | 37.3∼38.3 a , b | 39.98∼55.1 a , b , d | 51.9 a |
Ca2+ | 0.52∼2.4 b , c | 0.44 b | 0.81∼0.9 b , c | 2.2 c | 1.3 c | 0.85 b | 0.51 b | 0.25 b | ? |
Mg2+ | 0.37∼3.3 b , c | 1.19 b | 0.39∼1.5 b , c | 2.7 c | 1.7 c | 1.97 b | 2.61 b | 0.9 b | ? |
Cl− | 98.0∼122.14 a , b , c | 118.0∼143.37 a , b | 129.7∼135.76 b , c | 112.8 c | 116.7 c | 24.25∼31.0 a , b | 24.4∼39.09 a , b | 23.6∼27.04 a , b | 19.3 a |
Total P e | 2.25∼3.5 b , c | 9.22 b | 1.2∼1.72 b , c | 3.2 c | 4.5 c | 59.22∼82.5 b , f | 80.8∼93.76 b , f | 79.4∼88.7 b , f | 73.3 f |
HCO3 − | 23.0∼30.1 a , g , h | 10.6∼19 a , g | 22.9 h | 45.2 h | 8.7∼20.4 g , h | 2.7∼4.8 a , g | ? | 6.7 a | 6.7 a |
pH | 7.39∼7.5 a , g , h , i | 6.93∼7.31 a , g , i , j | 7.34 h | 7.66 h | 6.79∼7.26 g , h , j | 6.48∼6.64 a , g , i , j | 7.10∼7.18 g , i | 6.85∼6.88 a , g , i | 6.85 a |
Osmolarity k | 299.4∼311 a , c | 338 a | 306.6 c | 303.1 c | 300.5 c | 315 a | 340 a | 329 a | 339 a |
Data included from Levine and Marsh (1971).
Data included from Jenkins et al. (1980).
Data included from Clulow et al. (1994).
Data included from Turner (1984).
Data included from Hinton and Setchell (1980).
Data included from Caflisch (1992).
Data included from Newcombe et al. (2000).
Data included from Caflisch and DuBose (1990).
Data included from Levine and Kelly (1978).
Total P represents measuremetns including inorganic phosphorus, glycerophosphocholine and phosphocholine.
Osmolarity unit: mOsm/kg.
In the published article, there was an error in the Funding statement. The grant support from “Science and Technology Commission of Shanghai Municipality (STCSM19140903400)” was not included in the original statement, which is:
“This work is supported by NNSFC grants (31871166; 82071704) to WWS and startup of ShanghaiTech University.”
The correct Funding statement appears below.
“This work is supported by NNSFC grants (31871166; 82071704), Science and Technology Commission of Shanghai Municipality grant (19140903400), and the startup of ShanghaiTech University to WWS.”
The authors apologize for this error and state that this does not change the scientific conclusions of the article in any way. The original article has been updated.
Publisher’s note
All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.