Skip to main content
Polymers logoLink to Polymers
. 2022 Sep 11;14(18):3799. doi: 10.3390/polym14183799

Two-Way Shear Resistance of FRP Reinforced-Concrete Slabs: Data and a Comparative Study

Fahid Aslam 1, Mohamed AbdelMongy 2,3, Majed Alzara 2, Taha Ibrahim 4, Ahmed Farouk Deifalla 5,*, Ahmed M Yosri 2,*,
Editors: Saeed Mahini, Libo Yan
PMCID: PMC9501150  PMID: 36145944

Abstract

This study aims to investigate the two-way shear strength of concrete slabs with FRP reinforcements. Twenty-one strength models were briefly outlined and compared. In addition, information on a total of 248 concrete slabs with FRP reinforcements were collected from 50 different research studies. Moreover, behavior trends and correlations between their strength and various parameters were identified and discussed. Strength models were compared to each other with respect to the experimentally measured strength, which were conducted by comparing overall performance versus selected basic variables. Areas of future research were identified. Concluding remarks were outlined and discussed, which could help further the development of future design codes. The ACI is the least consistent model because it does not include the effects of size, dowel action, and depth-to-control perimeter ratio. While the EE-b is the most consistent model with respect to the size effect, concrete compressive strength, depth to control perimeter ratio, and the shear span-to-depth ratio. This is because of it using experimentally observed behavior as well as being based on mechanical bases.

Keywords: design, two-way shear, GFRP, CFRP, FRP, BFRP

1. Introduction

In 2021, victims of the collapse of a condominium building [1] that is shown in Figure 1(a) totaled 98 people. In addition, a parking garage collapsed suddenly on a playground in Spain [2], as shown in Figure 1(b). Moreover, most of the two-way shear designs of reinforced concrete (RC) slabs are empirical or semi-empirical. Thus, extensive research efforts are direct towards understanding the two-way shear types. However, the mechanism of the two-way shear of the slabs is complicated; thus, it is still open for investigation [3,4,5,6]. The two-way shear resistance of concrete slabs that are without shear reinforcements is composed of several resistance mechanisms, as follows: (1) flexure reinforcements resist shear through using dowel shear; (2) aggregates resist shear across the sides of the diagonal concrete crack through using aggregate interlock and friction; (3) uncracked concrete resists shear through using direct shear [7,8,9].

Figure 1.

Figure 1

Collapsed of (a) condominium building [1] and (b) a parking garage on a playground [2].

To avoid corrosion problems, replacing the conventional reinforcement with fiber-reinforced polymers (FRP) reinforcements in concrete slabs is a common solution [10]. In addition, FRP reinforcements are magnetic neutral and have a high strength-to-weight ratio. Thus, they are the best choice to use in buildings that are subjected to severe environmental conditions including, and not limited to, wet-dry cycles, de-icing salts, and freeze-thaw cycles. Many researchers have investigated the behavior of new and existing beams and slabs that are reinforced with FRP bars or fabrics under one-way and two-way shear as well as torsion, mostly through experimental investigations [11,12,13,14,15]. Many research studies have tackled the two-way shear of concrete FRP reinforcements, while very few mechanical models were developed for this case [8]. The FRP’s failure is brittle; thus, before failure, the FRP-reinforced concrete cracks are wider when compared to those in conventional RC [16,17,18]. Wider cracks significantly affect the various mechanisms of the two-way shear strength.

The traditional two-way shear design equations for RC slabs are based on theories that were developed in the early 1960s. These models were based on studies of that period’s tested specimens; however, over the last few decades, much more testing was conducted which show several drawbacks of these methods including, and not limited to, size effect and those models being severely unconservative in many situations. Hence, there is a room for improvements to the two-way shear design models, which could help design code developments [19,20].

This study aims to assess the available methods for study of the two-way shear strength of FRP-reinforced concrete slabs. A state-of-the-art review of design codes, guides, and models for the study of the two-way shear strength of FRP-reinforced concrete slabs was outlined. An extensive review of the experimental testing of the FRP-reinforced concrete slabs that were tested under two-way loads was compiled. The studies that used to extract the models and their experimental testing were collected through various engineering search engines including, and not limited to: Google Scholar, Science Direct, MDPI Hub, and Engineering Village. The strengths calculated using all models were compared with those that were measured by testing. Concluding remarks were outlined and discussed.

2. Research Significance

Many researchers have proposed design models that address the two-way shear strength of RC slabs with FRP. Although safety is the main goal for the design purposes, evaluating these design models is a necessity. The accuracy of these models was assessed based on data from a limited experimental database. Thus, this study provides the community with an extensive collection of models and tested specimens as well as a comparison between the accuracy of each of these models. These results can help to improve the code developments.

3. Simplified Strength Models

For the study of the two-way shear strength of FRP-RC slabs, several simplified strength models have been proposed, either by modifications for conventional concrete slabs or empirically based on limited test data. The two-way shear design provisions of the North American design codes have neglected the effect of flexure reinforcement on strength. They focused on the direct shear resistance of the compression zone. This could be reasonable for conventional steel reinforcements with relatively high stiffness when compared to the FRP ones. Thus, the direct shear component governs the two-way shear strength. However, due to the relatively lower stiffness of the FRP when compared to the steel one, a dowel action could be a more significant contributor to its strength. Details and the background of various models are outlined in this section. V is the two-way shear failure load. E is the Young’s modulus of the FRP. d is the effective depth. fc is the concrete compressive strength. ρ is the flexure reinforcement ratio. b and c are the column dimensions. A and B are the slab dimensions. Es is the Young’s modulus of the steel. b0.5d is the control perimeter at 0.5d, which is taken as 2b+c+2d. b1.5d is the control perimeter at 1.5d, which is taken as 2b+c+6d. b2.0d is the control perimeter at 2.0 d, which is taken as 2b+c+8d.

3.1. Gardner (1990)

In 1990, Gardner developed a strength model, which will be referred to herein as G [21]. It is based on an experimental database for two-way shear, and the existing design codes were assessed. Gardner concluded that considering the size effect and the flexure reinforcement ratio provides a more reliable design model; thus, when fitting it to the experimental database of that time, the two-way shear is calculated such that:

V=1.36 100ρfc131d14b1.5dd (1)

3.2. Japanese Approaches (1997), JSCE

In 1997, the JSCE [22] used a similar approach to the conventional North American design codes, and they implemented the assumption that the strength was proportional to the square root of the concrete compressive strength. Thus, they implemented the strain approach on the British Standard of that time and proposed that the two-way shear was calculated such that:

V=βdβρβrfPcd1αb0.5dd (2)

where βd=1000d141.5, βρ100ρEEs3=1.5, βr=1+11+0.25b0.5dd, fPcd=0.2fc 1.2, α=1+1.5ex+eyAB, and ex and ey are the loading eccentricity in the x and y direction of the slabs, respectively.

3.3. Elghandour (2000), EG [23]

In 2000, Elghandour developed a strength model, which will be referred to as EG [23]. The model was developed using the strain and stress approaches to determine the steel area equivalent to the FRP area, and it can be used in the conventional two-way shear models. Thus, they implemented the strain approach, with a limit of the value of 0.0045 for the strain and the British Standard of the time, and proposed that the two-way shear was calculated such that:

V=0.79fc2013100ρEEs1.813400d14b1.5dd (3)

3.4. Mattys and Taerwe (2000), MT

In 2000, Mattys and Taerwe, developed a strength model, which will be referred to herein as MT [24]. It was developed based on the observed behavior of the experimental testing of FRP-reinforced concrete slabs; their stiffness is less than that of conventional reinforced slabs. In addition, the depth and axial stiffness of FRP reinforcements have a significant effect on their strength; thus, they modified the British design code to be as follows:

V=1.36100ρfcEEs131d14b1.5dd (4)

3.5. Ospina (2003), O

In 2003, Ospina [25] developed a model (O), which is based on their experimental observations, and it was found that the strength is affected by the axial stiffness of the FRP reinforcements and the bond they have with the concrete. Thus, when it is modified, the MT model is expressed as follows:

V=2.77ρfc13 EEsb1.5dd (5)

3.6. Zaghloul (2003), Z

Zaghloul [26] has adapted the one-way shear design of the FRP-reinforced concrete of the Canadian design codes and multiplied it by a factor of two and introduced a perimeter size effect factor, such that:

V=0.07Eρfc130.44+5.16αsdb0.5d b0.5dd (6)

αs = 4, 3, and 2 for an inner connection, an edge connection, and a corner connection, respectively.

3.7. Jacbson (2005), Jb [27]

This is an empirical model which was developed through experimental testing.

V=4.5 ρfc121d14b1.5dd  (7)

3.8. ACI (2005), ACI [28]

This ACI model accounts for the effect of the direct shear of the compression zone of the concrete, where the ACI equation for the conventionally reinforced concrete slabs (0.3fcdb0.5d) is multiplied by the factor (2.5 k). Thus, the shear strength is calculated such that:

V=0.8fckdb0.5d (8)

where k=2ρn+ρn2ρn, modular ratio (n)=EEc, concrete young’s modulus, and Ec=4750fc.

3.9. Elgamal (2005), E [29]

Elgamal developed a model, which was based on the experimentally observed fact that the two-way shear is affected by the FRP axial stiffness, and the slab end conditions are in terms of their continuity or them having an edge beam. Thus, the strength was proposed, such that:

V=0.33fc20.62Eρ131+8db0.5d1.2Nb0.5dd (9)

where n = 0, 1, and 2 represents a simple slab, a continuous, one-sided slab, and a continuous, two-sided slab, respectively.

3.10. Zhang (2006), Zg [30,31]

Zhang developed a design model which included the following assumptions: (1) that two-way shear failure occurs after the critical diagonal shear crack passes through the compression zone; (2) that failure is related to concrete tensile strength; (3) that dowel action contributes to the strength. In addition, the model was calibrated using the experimental database that was available at that time, such that:

V=0.25+1.10 100ρEEs121d1/5fc13b1.5dd (10)

3.11. Theodorkopoulos and Swamy (2008), TS [32]

The proposed model was based on moment–shear interaction, which determined the compression zone depth using the tensile elastic stiffness of the FRP reinforcements and the bond between FRP reinforcements and the concrete.

V=0.117fc0.823100d162αfλf1+αfλfb0.5dd (11)

where λf=0.5561+1+48αf1, αf=0.058ρEfc0.33.

3.12. CSA-S806-12 (2012), CSA [33]

The design model was developed, based on the conventional concrete design code, however, it was modified for FRP reinforcements instead of steel ones.

V=b0.5dd0.0281+2βcEρfc130.147Eρfc130.19+αsdb0.5d0.056Eρfc13 (12)

βc= ratio between the long and short side of the loading area; αs = 4, 3, and 2 for an inner connection, an edge connection, and a corner connection, respectively. b0.5d=4c+d.

3.13. Nguyen and Rovnak (2013), NR [34]

A fracture mechanics-based semi-empirical model was developed, which considered the effects of the following: (1) span-to-depth ratio; (2) the effective depth; (3) the dowel action.

V=400d0.8daρ/1000.33E0.33fc0.3b0.5d (13)

where a is the slab’s shear span.

3.14. Hassan, et al. (2017), H [35]

The model is a modification of the CSA which combines the three equations into a single formula. Then, it used a multi-linear regression technique to fit the 69 specimens in the experimental database using a power equation, such that:

V=0.0650.65+4db0.5dEρfc13125d16b0.5dd (14)

3.15. Kara and Sinani (2017), KS [36]

The KS model is a modification of the MT model that replaces the coefficient with 0.46 instead of 1.36 and removes the d parameter, such that:

V=0.46100ρfcEEs13b1.5dd (15)

3.16. Oller, et al. (2018), CCCM [37]

The CCCM model was developed, based on the model by Mari and co-workers [38], and it is a unified model for two-way shear; thus, it applies the following assumptions: (1) the strains are higher due to the lower modulus of elasticity of the FRP bars; (2) the cracks are wider; (3) the basic perimeter at the point of failure is lower in an FRP-reinforced concrete (RC) slab than it is in a conventional RC slab. Thus, the shear capacity is calculated such that:

V=ξXd2.5fctβb0.5dd0.25fc231.8ξKc+20dob0.5dd (16)

where ξ=21+d200da 0.20.45, Xd=0.75αeρ13, fct=0.3fc234.60 MPa, do=d 100 mm, αe=EEc, Kc=Xd0.2, Ec=22000fc100.339 GPa.

3.17. Hemzah, et al. (2019), Hz [39]

Using numerical modeling and an experimental database, a two-way shear formula which considers the flexure reinforcement ratio and type, the compressive strength of concrete, and the shape of the column was developed, such that:

V=13fc12k90fc0.335ρ0.39EEs0.3b0.5dd (17)

k=0.77 and 0.55  for circular and rectangular columns, respectively.

3.18. Elgendy and Elsalakawy (2020), EE [40]

Considering the eccentricity of the slab-column joint, the H model and the EG model were modified, such that:

V=0.33fc120.62Eρ131+2αsdb0.5d1.2Nb0.5dd (18)
V=0.0650.65+αsdb0.5dEρfc13125d16b0.5dd (19)

αs = 4, 3, and 2 for an inner connection, an edge connection, and a corner connection, respectively. N = 1, 2, and 3 for a simple slab, a continuous, one-sided slab, and a continuous, two-sided slab, respectively.

3.19. Ju, et al. (2021), Ju [41]

To guarantee the lowest probability of failure, the design strength was calculated with the probabilistic method with 95% confidence; thus, the Monte Carlo Simulation (MCS) was used to develop the probability distribution with key uncertain factors, such that:

V=2.3 100ρEEsfc12db0.5d12b0.5dd (20)

3.20. Alrudaini (2022), A [42]

A rational model is developed, which considers the following: (1) concrete compressive strength, elastic properties of reinforcement, reinforcement ratio, and slab depth to the effective perimeter. Each parameter was fitted to the measured strength, such that:

V=0.41 ρEfc13db0.5d15b0.5dd (21)

Table 1 shows a comparison between the various design models, where it is clear that there is a lack of agreement among researchers regarding the considered parameters and methodology used to account for it. All design methods included the effect of concrete compressive strength in terms of fc13 or fc12. Most of the methods included the dowel action in terms of the flexure reinforcement, which was taken as ρ13 or ρ12. More than half of the methods included the FRP type in terms of Young’s modulus, which was taken as E13., or E12. About half of the methods included the size effect in terms of 1d14, 1d15, 1d12, or 21+d200 and included the ratio between the critical perimeter and the depth in terms of 0.44+20.8db0.5d, 1+8db0.5d, 0.19+4db0.5d, 0.65+4db0.5d, 1+8db0.5d, 0.65+4db0.5d, db0.5d12, or db0.5d15. On the other hand, very few models included the compression zone and the shear span-to-depth ratio.

Table 1.

Comparison between design models.

Design Model Critical Perimeter Location Size Effect Dowel Action Young’s Modulus Concrete Strength Control Perimeter-to-Depth Ratio Compression Zone Depth Shear Span-to
-Depth Ratio
G 1.5 d d14 ρ13 ------ fc13 ------ ------ ------
JSCE 0.5 d d14 ρ13 E13 fc12 1+11+0.25b0.5dd ------ ------
Gd 1.5 d d14 ρ13 E13 fc13 ------ ------ ------
MT 1.5 d d14 ρ13 E13 fc13 ------ ------ ------
O 1.5 d ------ ρ13 E12 fc13 ------ ------ ------
Z 0.5 d ------ ρ13 E13 fc13 0.44+20.8db0.5d ------ ------
Jb 1.5 d d14 ρ12 ------ fc12 ------ ------ ------
ACI 0.5 d ------ ------ ------ fc12 ------ k ------
EG 0.5 d ------ ρ13 E13 fc12 1+8db0.5d ------ ------
Zg 1.5 d d15 ρ12 E12 fc13 ------ ------ ------
TS 0.5 d d16 ------ ------ fc23 ------ ------ ------
CSA 0.5 d ------ ρ13 E13 fc13 0.19+4db0.5d ------ ------
NR 0.5 d d12 ρ13 E13 fc13 ------ ------ ad
H 0.5 d d16 ρ13 E13 fc13 0.65+4db0.5d ------ ------
KS 1.5 d ------ ρ13 E13 fc13 ------ ------ ------
CCCM 0.5 d 2/1+d200 ρ13 E13 fc23 ------ Xd ad0.2
Hz 0.5 d ------ ρ0.39 E0;3 fc16 ------ ------ ------
EE-(a) 0.5 d ------ ρ13 E13 fc12 1+8db0.5d ------ ------
EE-(b) 0.5 d d16 ρ13 E13 fc13 0.65+4db0.5d ------ ------
Ju 0.5 d ------ ρ12 E12 fc12 db0.5d12 ------ ------
A 0.5 d ------ ρ13 E13 fc13 db0.5d15 ------ ------

4. Experimental Database Profile

Over the last 30 years, a significant number of experimentally tested specimens failed due to the effect of two-way shear. The most comprehensive experimental database, when compared to those of previous studies [2,39,41,43], was produced with a total of 248 slabs with FRP reinforcements that were collected from 50 different research studies. All the gathered slabs were subjected to two-way shear loading and failed, suddenly, under the application of two-way shear, as shown in Figure 2.

Figure 2.

Figure 2

Two-way shear (a) failure isometric view; (b) failure elevation; (c) loading test setup schematic; (d) actual loading test setup [43,44].

Table 2 shows a detailed description of the experimental database, where E is the Young’s modulus of FRP, d is the effective depth, fc is the concrete compressive strength, ρ is the flexure reinforcement ratio, b and c are the column dimensions, A and B are the slab dimensions, and FRP type including carbon FRP (CFRP), glass FRP (GFRP), and Basalt FRP (BFRP) are listed. Although FRP reinforcements could have several shapes and configurations, these variations were considered in terms of ρ and E. Figure 3 shows the frequency and the range of each variable. All variables cover a wide range of values, while also being normally distributed.

Table 2.

Experimental database for RC slabs with FRP reinforcements under two-way shear loading.

Year of Study Specimen Label A (mm) B (mm) b (mm) c (mm) d (mm) fc’ (MPa) FRP Type ρ(%) E (GPa) V (kN) #
1993 CFRC-SN1 690 690 75 75 61 42.4 CFRP 0.95 113 93 [45]
CFRC-SN2 690 690 75 75 61 44.6 CFRP 0.95 113 78
CFRC-SN3 690 690 100 100 61 39 CFRP 0.95 113 96
CFRC-SN4 690 690 100 100 61 36.6 CFRP 0.95 113 99
1995 1 600 600 100 100 55 41 CFRP 0.31 100 65 [46]
2 600 600 100 100 55 52.9 CFRP 0.31 100 61
3 600 600 100 100 55 41.5 CFRP 0.31 100 72
1995 1 1800 1500 250 250 76 30 CFRP 2.05 143 186 [47]
2 1800 1500 250 250 76 30 CFRP 2.05 143 179
3 1800 1500 250 250 76 30 CFRP 1.81 143 199
4 1800 1500 250 250 76 30 CFRP 2.05 156 198
5 1800 1500 250 250 76 30 CFRP 1.81 156 201
6 1800 1500 250 250 76 30 CFRP 1.49 156 190
1999 1 3000 1800 575 225 175 43 GFRP 1 41.3 500 [48]
2 3000 1800 575 225 175 43 GFRP 1 41.3 1050
3 3000 1800 575 225 175 43 GFRP 1 39.3 875
4 3000 1800 575 225 175 43 GFRP 1 39.3 1090
5 3000 1800 575 225 175 43 GFRP 1 39.3 1180
C1 3000 1800 575 225 175 55 CFRP 1 100 1000
C2 3000 1800 575 225 175 55 CFRP 1 100 1200
C3 3000 1800 575 225 175 55 CFRP 1 100 1328
H2 3000 1800 575 225 175 45 Hybrid 1 160 1055
H4 3000 1800 575 225 175 45 Hybrid 1 160 1096
H5 3000 1800 575 225 175 45 Hybrid 1 160 1183
2000 C1 1000 1000 150 150 96 37.3 CFRP 0.27 91.8 181 [24]
C1’ 1000 1000 230 230 95 35.7 CFRP 0.27 91.8 189
C2 1000 1000 150 150 95 36.3 CFRP 1.05 95 255
C2’ 1000 1000 230 230 95 36.3 CFRP 1.05 95 273
C3 1000 1000 150 150 126 33.8 CFRP 0.52 92 347
C3’ 1000 1000 230 230 126 34.3 CFRP 0.52 92 343
CS 1000 1000 150 150 95 32.6 CFRP 0.19 148 142
CS’ 1000 1000 230 230 95 33.2 CFRP 0.19 148 150
H1 1000 1000 150 150 95 118 HFRP 0.62 37.3 207
H2 1000 1000 150 150 89 35.8 HFRP 3.76 40.7 231
H2’ 1000 1000 80 80 89 35.9 HFRP 3.76 40.7 171
H3 1000 1000 150 150 122 32.1 HFRP 1.22 44.8 237
H3’ 1000 1000 80 80 122 32.1 HFRP 1.22 44.8 217
2000 1 2000 2500 250 150 162 42 GFRP 0.28 85 622 [49]
2 2000 2500 250 150 162 42 GFRP 0.28 85 698
3 2000 2500 250 150 162 42 GFRP 0.28 85 575
4 2000 2500 250 150 162 42 GFRP 0.28 85 534
5 2000 2500 250 150 162 42 GFRP 0.28 85 584
2000 1 1800 3000 575 225 165 59 CFRP 0.57 147 1000 [50]
2 1800 3000 575 225 165 59 CFRP 0.57 147 1200
3 1800 3000 575 225 165 59 CFRP 0.57 147 1328
2000 1 2000 4000 500 250 138 35 GFRP 2.4 42 756 [51]
2003 SG1 2000 2000 200 200 142 33.3 GFRP 0.22 45 170 [23]
SC1 2000 2000 200 200 142 34.7 CFRP 0.18 110 229
SG2 2000 2000 200 200 142 46.6 GFRP 0.47 45 271
SG3 2000 2000 200 200 142 30.3 GFRP 0.47 45 237
SC2 2000 2000 200 200 142 29.6 CFRP 0.43 110 317
2003 GFR-1 2150 2150 250 250 120 29.5 GFRP 0.73 34 217 [25]
GFR-2 2150 2150 250 250 120 28.9 GFRP 1.46 34 260
NEF-1 2150 2150 250 250 120 37.5 GFRP 0.87 28.4 206
2003 ZJF5 1760 1760 250 250 75 45 CFRP- 1 100 234 [26]
2004 G-S1 1830 1830 250 250 100 40 GFRP 1.18 42 249 [52]
G-S2 1830 1830 250 250 100 35 GFRP 1.05 42 218
G-S3 1830 1830 250 250 100 29 GFRP 1.67 42 240
G-S4 1830 1830 250 250 100 26 GFRP 0.95 42 210
2005 1 2300 2000 635 250 175 27.6 GFRP 0.98 33 537 [27]
2 2300 2000 635 250 175 27.6 GFRP 0.98 33 536
3 2300 2000 635 250 175 27.6 GFRP 0.95 33 531
7 2000 2000 635 250 175 27.6 GFRP 0.98 33 721
8 2000 2000 635 250 175 27.6 GFRP 0.98 33 897
2005 G-S1 3000 2500 600 250 159 49.6 GFRP 1 44.6 740 [29]
G-S2 3000 2500 600 250 159 44.3 GFRP 1.99 38.5 712
G-S3 3000 2500 600 250 159 49.2 GFRP 1.21 46.5 732
C-S1 3000 2500 600 250 165 49.6 CFRP 0.35 122.5 674
C-S2 3000 2500 600 250 165 44.3 CFRP 0.69 122.5 799
2005 GS2 1830 1830 250 250 100 35 GFRP 1.05 42 218 [31]
GSHS 1830 1830 250 250 100 71 GFRP 1.18 42 275
2006 CS1 1900 1900 250 250 100 31 CFRP 0.41 120 251 [30]
CS2 1900 1900 250 250 100 33 CFRP 0.54 120 293
CS3 1900 1900 250 250 100 25.7 CFRP 0.75 120 285
CSHD1 1900 1900 250 250 100 35.9 CFRP 0.54 120 325
CSHD2 1900 1900 250 250 100 38.6 CFRP 0.75 120 360
CSHS1 1900 1900 250 250 150 85.6 CFRP 0.36 120 399
CHSHS2 1900 1900 250 250 150 98.3 CFRP 0.5 120 446
2007 1 1900 1900 250 250 110 70 GFRP 1 41 282 [53]
2 1900 1900 250 250 110 70 GFRP 1.2 41 319
3 1900 1900 250 250 110 70 GFRP 1.5 41 384
4 1900 1900 250 250 160 70 GFRP 1.2 41 589
5 1900 1900 250 250 145 70 GFRP 1.2 41 487
6 1900 1900 250 250 135 70 GFRP 1.2 41 437
2007 ZJEF1 1760 1000 250 250 120 25 CFRP 1.37 100 188 [54]
ZJEF2 1760 1000 250 250 120 27 CFRP 0.94 100 156
ZJEF3 1760 1000 250 250 120 55 CFRP 1.37 100 211
ZJEF5 1760 1000 250 250 81 28 CFRP 1.37 100 97
ZJEF7 1760 1000 450 250 120 26 CFRP 1.37 100 196
ZJF8 1760 1760 350 250 101 28 CFRP 1.48 100 178
ZJF9 1760 1760 250 250 100 57.6 CFRP 1.48 100 272
2007 G-S4 3000 2500 600 250 156 44.1 GFRP 1.2 44.5 707 [55]
G-S5 3000 2500 600 250 156 44.1 GFRP 1.2 44.5 735
2008 F1 1200 1200 200 200 82 37.4 GFRP 1.1 46 165 [56]
F2 1200 1200 200 200 112 33 GFRP 0.81 46 170
F3 1200 1200 200 200 82 38.2 GFRP 1.29 46 210
F4 1200 1200 200 200 82 39.7 GFRP 1.54 46 230
2009 GFU1 2300 2300 225 225 110 36.3 GFRP 1.17 48.2 222 [57]
GFB2 2300 2300 225 225 110 36.3 GFRP 2.14 48.2 246
GFB3 2300 2300 225 225 110 36.3 GFRP 3 48.2 248
GFBF3 2300 2300 225 225 110 33.8 GFRP 3 48.2 330
2010 S3 1500 1500 150 150 135 33.5 BFRP 0.29 100 145 [58]
S4 1500 1500 150 150 135 35.6 BFRP 0.55 100 275
S5 1500 1500 150 150 135 32.8 BFRP 0.42 100 235
S6 1500 1500 150 150 135 32.5 BFRP 0.42 100 225
S7 1500 1500 150 150 135 22.6 BFRP 0.42 100 170
S8 1500 1500 150 150 135 41.8 BFRP 0.42 100 235
S9 1500 1500 150 150 135 40.6 BFRP 0.42 100 200
2010 NC-G-45 300 300 25 25 45 47.8 GFRP 0.78 76 44 [59]
NC-G-0/90 300 300 25 25 45 47.8 GFRP 0.78 76 45
NC-C-45 300 300 25 25 45 47.8 CFRP 0.24 230 39
NC-C-0/90 300 300 25 25 45 47.8 CFRP 0.24 230 45
SFRC-C-45 300 300 25 25 45 47.8 CFRP 0.24 230 63
UHPC-C-45 300 300 25 25 45 179 CFRP 0.24 230 97
UHPC-C-0/90 300 300 25 25 45 179 CFRP 0.24 230 98
2010 A 1500 1500 150 150 130 22.16 GFRP 0.42 45.6 176 [60]
B-2 1500 1500 150 150 130 32.46 GFRP 0.42 45.6 209
B-3 1500 1500 150 150 130 32.4 GFRP 0.55 45.6 245
B-4 1500 1500 150 150 130 32.8 GFRP 0.29 45.6 167
B-5 1500 1500 150 150 130 33.2 GFRP 0.42 45.6 217
B-6 1500 1500 150 150 130 28.32 GFRP 0.42 45.6 222
B-7 1500 1500 150 150 130 46.05 GFRP 0.42 45.6 253
2011 G200n 3000 2500 600 250 155 49.1 GFRP 1.20 43 732 [61]
G175N 3000 2000 600 250 135 35.2 GFRP 1.20 43 484
G150N 3000 2000 600 250 110 35.2 GFRP 1.20 43 362
G175h 3000 2000 600 250 135 64.8 GFRP 1.20 43 704
G175n0.7 3000 2000 600 250 135 53.1 GFRP 0.7 43 549
G175n0.35 3000 2000 600 250 137 53.1 GFRP 0.35 43 506
C175N 3000 2000 600 250 140 40.3 GFRP 0.40 122 530
2012 A 1500 1500 150 150 130 22.2 GFRP 0.42 45.6 176 [62]
B-2 1500 1500 150 150 130 32.5 GFRP 0.42 45.6 209
B-3 1500 1500 150 150 130 32.4 GFRP 0.55 45.6 245
B-4 1500 1500 150 150 130 32.8 GFRP 0.29 45.6 167
C 1500 1500 150 150 130 44.4 GFRP 0.42 45.6 252
2013 GSL-PUNC-0.4 2200 2200 200 200 130 48.8 GFRP 0.48 48 180 [34]
GSL-PUNC-0.5 2200 2200 200 200 130 48.8 GFRP 0.68 48 212
GSL-PUNC-0.6 2200 2200 200 200 130 48.8 GFRP 0.92 48 244
2013 G (0.7) 30/20 2500 2500 300 300 134 34.3 GFRP 0.71 48.2 329 [35]
G (1.6) 30/20 2500 2500 300 300 131 38.6 GFRP 1.56 48.1 431
G (1.6) 30/20-H 2500 2500 300 300 131 75.8 GFRP 1.56 57.4 547
G (1.2) 30/20 2500 2500 300 300 131 37.5 GFRP 1.21 64.9 438
G (0.3) 30/35 2500 2500 300 300 284 34.3 GFRP 0.34 48.2 825
G (0.7) 30/35 2500 2500 300 300 284 39.4 GFRP 0.73 48.1 1071
G (1.6) 30/35 2500 2500 300 300 275 38.2 GFRP 1.61 56.7 1492
G (1.6) 30/35-H 2500 2500 300 300 275 75.8 GFRP 1.61 56.7 1600
G(0.7) 30/20-B 2500 2500 300 300 134 38.6 GFRP 0.71 48.2 386
G(0.7) 45/20 2500 2500 300 300 134 44.9 GFRP 0.71 48.2 400
G (1.6) 45/20-B 2500 2500 300 300 131 39.4 GFRP 1.56 48.1 511
G (0.3) 30/35-B 2500 2500 300 300 284 39.4 GFRP 0.34 48.2 781
G (0.7) 30/35-B-2 2500 2500 300 300 281 46.7 GFRP 0.73 48.1 1195
G (0.3) 45/35 2500 2500 300 300 284 48.6 GFRP 0.34 48.2 911
G (1.6) 30/20-B 2500 2500 300 300 131 32.4 GFRP 1.56 48.1 451
G (1.6) 45/20 2500 2500 300 300 131 32.4 GFRP 1.56 48.1 504
G (0.7) 30/35-B-1 2500 2500 300 300 181 29.6 GFRP 0.73 48.1 1027
G(0.3) 45/35-B 2500 2500 300 300 284 32.4 GFRP 0.34 48.2 1020
G (0.7) 45/35 2500 2500 300 300 281 29.6 GFRP 0.73 48.1 1248
2015 GSC-0.9-XX-0.4 2800 1500 300 300 160 41 GFRP 0.9 60.505 251 [63]
GSC-1.35-XX-0.4 2800 1500 300 300 160 41 GFRP 1.35 60.505 268
GSC-1.8-XX-0.4 2800 1500 300 300 160 41 GFRP 1.7 60.505 277
GSC-0.9-XX-0.2 2800 1500 300 300 160 41 GFRP 0.85 60.505 239
GSC-0.9-XX-0.3 2800 1500 300 300 160 41 GFRP 0.9 60.505 159
GRD-0.9-XX-0.4 2800 1500 300 300 160 41 GFRP 0.9 59.877 191
2015 G-0.6%-12-125 T&B 1425 500 500 25 119 68.1 GFRP 0.6 67.4 344 [64]
G-0.6%-16-300 T&B 1425 500 500 25 117 65.7 GFRP 0.6 67.4 365
B-0.6%-12-125 T&B 1425 500 500 25 119 69.3 BFRP 0.6 54 300
B-0.6%-16-300 T&B 1425 500 500 25 117 66.1 BFRP 0.6 54 295
2016 GSC-0.9-XX-0.4 2600 1450 300 300 160 81 GFRP 0.87 60.505 251 [65]
GSC-1.35-XX-0.5 2600 1450 300 300 160 85 GFRP 1.28 60.505 272
GSC-1.8-XX-0.4 2600 1450 300 300 160 80 GFRP 1.7 60.505 288
2016 S2-B 3000 2000 600 250 160 48.81 BFRP 0.8 69.3 548 [66]
S3-B 3000 2000 600 250 160 42.2 BFRP 0.79 69.3 665
S4-B 3000 2000 600 250 160 42.2 BFRP 0.8 69.3 566
S5-B 3000 2000 600 250 160 47.9 BFRP 1.2 69.3 716
S6-B 3000 2000 600 250 160 47.9 BFRP 0.4 69.3 576
S7-B 3000 2000 600 250 160 47.9 BFRP 0.4 69.3 436
2016 GN-0.65 2600 2600 300 300 160 42 GFRP 0.65 69.3 363 [67]
GN-0.98 2600 2600 300 300 160 38 GFRP 0.98 68 378
GN-1.30 2600 2600 300 300 160 39 GFRP 1.3 68 425
GH-0.65 2600 2600 300 300 160 70 GFRP 0.65 68 380
G-00-XX 2800 2800 300 300 160 38 GFRP 0.65 68 421 [68]
2016 G-15-XX 2800 2800 300 300 160 42 GFRP 0.65 68 363
G-30-XX 2800 2800 300 300 160 42 GFRP 0.65 68 296
R-15-XX 2800 2800 300 300 160 40 GFRP 0.65 68 320
2017 NW59 800 800 250 250 176 59 GFRP 0.703 68 719 [69]
2017 SG1 1100 1100 150 150 62 29.8 GFRP 0.22 47 136 [70]
SO1 1100 1100 150 150 62 37.3 GFRP 0.13 47 68
SO2 1100 1100 150 150 62 32.6 GFRP 0.13 47 85
SO3 1100 1100 150 150 62 30.5 GFRP 0.22 47 80
SO4 1100 1100 150 150 62 35.4 GFRP 0.22 47 100
SO5 1100 1100 150 150 62 30.1 GFRP 0.22 47 102
2018 GFS1 3000 2200 200 200 180 36.7 GFRP 1.57 47 410 [71]
GFS2 3000 2200 200 200 180 36.7 GFRP 1.2 47 360
GFS3 3000 2200 200 200 180 36.7 GFRP 0.79 47 370
2018 H-1.0-XX 2800 2800 300 300 160 80 GFRP 0.98 65 461 [72]
H-1.5-XX 2800 2800 300 300 160 84 GFRP 1.46 65 541
H-2.0-XX 2800 2800 300 300 160 87 GFRP 1.93 65 604
2019 C-F-S-10-4 600 600 100 100 80 51 CFRP 0.3 144 103 [39]
C-F-S-10-6 600 600 100 100 80 52 CFRP 0.45 144 127
S-F-D-10-4 600 600 100 100 80 46 CFRP 0.6 144 112
S-F-D-10-6 600 600 100 100 80 60 CFRP 0.9 144 129
S-F-S-10-4 600 600 100 100 80 52 CFRP 0.3 144 79
S-F-S-10-6 600 600 100 100 80 48 CFRP 0.45 144 107
S-F-S-7.5-4 600 600 100 100 60 49 CFRP 0.41 144 57
S-F-S-7.5-6 600 600 100 100 60 49 CFRP 0.61 144 79
2019 G 2500 1350 300 300 160 41.4 GFRP 1.55 65 314 [73]
2019 G1 (1.06) 2500 2500 300 300 151 52 GFRP 1.06 62.6 140 [74]
G2 (1.51) 2500 2500 300 300 151 92 GFRP 1.51 62.6 140
G3(1.06)-SL 2500 2500 300 300 151 45 GFRP 1.06 62.6 180
2020 A30-1 1500 1500 300 300 88 27.4 GFRP 1.28 51.1 191 [75]
A30-2 1500 1500 300 300 108 27.3 GFRP 1.05 51.1 289
A30-3 1500 1500 300 300 138 26.2 GFRP 0.82 51.1 413
A30-4 1500 1500 350 350 86 26.8 GFRP 1.31 51.1 209
A40-1 1500 1500 350 350 88 28.2 GFRP 1.28 51.1 232
A40-2 1500 1500 350 350 88 26.4 GFRP 0.89 51.1 221
A40-3 1500 1500 300 300 88 28.6 GFRP 1.28 51.1 236
A50-1 1500 1500 300 300 88 29.2 GFRP 1.28 51.1 253
A50-2 1500 1500 300 300 90 32.2 GFRP 0.87 54.1 237
A50-3 1500 1500 350 350 88 26.7 GFRP 1.28 51.1 280
2020 S40-1 1500 1500 300 300 88 32.3 GFRP 0.98 51.1 314 [76]
S50-1 1500 1500 300 300 86 43.2 GFRP 0.7 54.4 187
2020 G4(1.06)-H 2500 2500 300 300 151 92 GFRP 1.06 62.6 134 [77]
2020 F1 1600 1600 200 200 125 24.97 CFRP 0.89 123 262 [78]
2021 G-N-0.3 2500 1300 300 300 160 37.1 GFRP 1.04 65 260 [79]
G-H-0.3 3000 2200 200 200 160 85.8 GFRP 1.04 65 306
G-N-0.6 3000 2200 200 200 160 38.8 GFRP 1.04 65 178
G-H-0.6 3000 2200 200 200 160 86 GFRP 1.04 65 213
2021 0F-605 2000 2000 250 250 125 38.2 GFRP 2.81 50.6 463 [80]
0F-80F 2000 2000 250 250 125 38.2 GFRP 2.11 50.6 486
0F-1105 2000 2000 250 250 125 38.2 GFRP 1.53 50.6 436
1.25F-60S 2000 2000 250 250 125 38.2 GFRP 2.81 50.6 455
1.25F-80S 2000 2000 250 250 125 38.2 GFRP 2.11 50.6 506
1.25F-110S 2000 2000 250 250 125 38.2 GFRP 1.53 50.6 498
2022 SA1 500 500 55 55 36 45 BFRP 0.84 50 30 [81]
SA2 500 500 55 55 36 45 GFRP 0.84 42 28
SA4 500 500 55 55 36 45 BFRP 0.56 50 26
SA5 500 500 55 55 36 45 GFRP 0.56 42 24
SA7 500 500 55 55 36 65 BFRP 0.84 50 35
SA0 500 500 55 55 36 45 BFRP 0.84 50 28
2022 CFRP1 1670 1670 1075 1075 52 29.62 CFRP 0.36 140 169 [82]
CFRP2 1670 1670 1075 1075 52 34.59 CFRP 0.36 140 178
CFRP3 1670 1670 1075 1075 52 34.59 CFRP 0.36 140 208
BFRP1 1670 1670 1075 1075 52 29.62 BFRP 0.36 55 103
BFRP2 1670 1670 1075 1075 52 34.59 BFRP 0.36 55 120
BFRP3 1670 1670 1075 1075 52 34.59 BFRP 0.36 55 144
Minimum 300 300 25 25 36 22.16 0.13 28.4 24.34
Maximum 3000 4000 1075 1075 284 179 3.76 230 1600
Mean 1915 1715 303 235 125 44 1 75 372
Variation 40% 39% 66% 65% 40% 44% 64% 55% 82%

Figure 3.

Figure 3

Frequencies and ranges of the tested column-slab connections with FRP.

5. Behavior Patterns

Based on the existing models and previous studies of slabs, the relationship between the shear stress (V/bod) and the effective parameters including d, E, ρ, fc’, d/bo, and a/d is a power relationship. Thus, Figure 4 shows the scatter plots for the pattern of the log of the shear stress versus the log of the effective parameters. The scatter plots do not allow a straightforward interpretation of the data because of the significant dispersion and poor distribution of the test parameters; thus, the best regression fit line and the Pearson correlation coefficients (r) are shown in Figure 4. The inclination of the best fit lines between the stress and basic variables d, E, ρ, fc’, d/bo, and a/d were the values of −0.19, 0.19, 0.05, 0.34, 0.33, and 0.41, respectively. Comparing these values to those that were used in selected models, as shown in Table 1, it can be shown that variables ρ and fc’ have quite similar power coefficients, while E, d/bo, and a/d are significantly different, and d is only like that of one selected model.

Figure 4.

Figure 4

Stress versus basic variables.

6. Pearson Correlation

The correlation coefficients between the shear stress and the basic variables d, E, ρ, fc’, d/bo, and a/d were calculated, as shown in Figure 4, where their values are −0.19, 0.21, 0.07, 0.23, −0.34, and −0.43, respectively. Therefore, the evidence is sufficient to say that the shear strength is correlated to the basic variables in a reasonable manner, except for the flexure reinforcement ratio. This could be because the effect of the flexure reinforcement varies significantly based on its value [83]. Since the experimental database covered a wide range of flexure reinforcement ratio values, it provided a misleading value for the correlation coefficient.

7. Comparison between Selected Models

All collected models were used to calculate the strengths of the slab column connections that were in the experimental database. Three categories of comparison were defined: graphical, central tendency, and statistical goodness-of-fit. The ratio between the measured and calculated strength was taken as the safety ratio (SR). An SR value that is close to unity means that the prediction is accurate. An SR value that is more than the unity indicates that the prediction is conservative. An SR value that is less than the unity mean that the shear strength was overestimated and so, the prediction is conservative. Statistical measures in terms of the coefficient of determination (R2), the root mean square error (RMSE), the mean average error (MAE), the mean, the coefficient of variation (C.O.V.), the lower value with a 95% confidence level (Lower 95%), the maximum value, and minimum value were applied on the SR for each selected model, as shown in Table 3 and Figure 5. Table 3 shows central tendency and statistical goodness-of-fit for all the selected models, which is helpful for the future development of the design models. The JSCE, the ACI, and the H models are over-conservative, with an average value of 2.71, 2.18, and 2.16, respectively. The Zg, the EE-b, the Ju, and the A models are more consistent with respect to other models, where the coefficient of variation values of these were 35%, 35%, 36%, and 36%, respectively.

Table 3.

Statistical measures for all strength models.

Design Model R2 RMSE MAE Mean C.O.V. Lower 95% Maximum Minimum
G 0.67 205 144 0.82 0.38 0.78 1.85 0.15
JSCE 0.69 337 238 2.71 0.38 2.58 8.08 0.69
Gd 0.69 776 653 0.36 0.37 0.34 0.78 0.08
MT 0.69 183 121 1.18 0.36 1.13 2.92 0.23
O 0.71 170 110 1.00 0.38 0.95 3.01 0.18
Z 0.67 200 126 0.94 0.38 0.90 2.81 0.16
Jb 0.67 182 110 1.15 0.38 1.10 2.59 0.21
ACI 0.69 272 194 2.18 0.45 2.06 6.90 0.36
Eg 0.68 222 137 0.86 0.37 0.82 2.59 0.13
Zg 0.70 166 106 1.00 0.35 0.96 2.43 0.19
TS 0.70 255 176 1.78 0.36 1.70 3.96 0.33
CSA 0.72 165 110 1.19 0.40 1.13 3.17 0.21
NR 0.56 360 252 0.63 0.45 0.60 1.60 0.14
H 0.70 290 203 2.16 0.36 2.07 5.56 0.40
KS 0.71 163 103 1.07 0.37 1.02 3.07 0.19
CCCM 0.67 198 126 1.06 0.44 1.00 3.48 0.22
Hz 0.72 164 105 1.00 0.45 0.95 3.54 0.19
EE-a 0.67 305 195 0.74 0.38 0.70 2.27 0.11
EE-b 0.70 233 160 1.61 0.35 1.54 4.24 0.30
Ju 0.70 173 117 1.26 0.36 1.20 3.60 0.22
A 0.71 163 106 1.13 0.36 1.07 3.21 0.20

Figure 5.

Figure 5

The performance of selected models.

Figure 5 shows a Box plot for all the selected models. A large dispersion and extreme values are observed in the ACI model. Also, severely un-conservative predictions resulted from the application of the Gd and NR models. The recent models (i.e., Ju, A, Hz, and EE-a) provide accurate predictions for the strength (when the mean is close to the unity), as shown in Figure 6. However, the consistency in these models is still lacking (i.e., C.O.V. is higher than 35%), as shown in Table 3. Models considering basic variables in a power form equation seem to be the most accurate and consistent when they are compared with the mechanically based model (CCCM) or the fracture-based model (NR). In addition, from Figure 5, it is clear that each method was developed or calibrated for a nonsystematic margin of safety which was defined by the judgment and experience of each developer(s). This should be managed by a reliability assessment that includes the resistance and load uncertainty. Although it is an interesting topic, it is not in the scope of this study, but it can be the subject of further studies. Moreover, there is a need for further improved mechanically based models that make physical sense, while being simple in their design.

Figure 6.

Figure 6

The effect of depth on the SR value, calculated using selected models. (a) Design codes; (b) Models.

Figure 5, Figure 6, Figure 7, Figure 8, Figure 9, Figure 10 and Figure 11 shows the SR value, which was calculated using different models, versus the value of the selected effective variable. Although the SR value is affected by the values of the various variables and not only the specific variable in the figure, it is assumed that the presence of the noise, because of the other variables, is insignificant with respect to the specific variable that is in the figure. It is worth noting that this approach was implemented in several pioneering studies as a base for international design codes [11,19,28,33,37,38,42]. In addition, some models do not include that specific variable, however, the experimentally measured strength includes the effect of that variable. Thus, the model’s ability to represent the true value of the strength can be evaluated properly with respect to the effect of that specific variable.

Figure 7.

Figure 7

The effect of the concrete compressive strength on the SR value, calculated using selected models. (a) Design codes; (b) Models.

Figure 8.

Figure 8

The effect of the flexure reinforcement ratio on the SR value, calculated using selected models. (a) Design codes; (b) Models.

Figure 9.

Figure 9

The effect of the Young’s modulus on the SR value, calculated using selected models. (a) Design codes; (b) Models.

Figure 10.

Figure 10

The effect of the ratio between the control perimeter and depth on the SR value, calculated using selected models. (a) Design codes; (b) Models.

Figure 11.

Figure 11

The effect of the shear span-to-depth ratio on the SR value, calculated using selected models. (a) Design codes; (b) Models.

7.1. Depth

Figure 6 shows the SR value that was calculated using the ACI model; the JSCE model; the CSA model; the CCCM model; the Ju model; the EE-b model versus the effective depth. In addition, the best fit line was plotted, whose slope was 0.0011, −0.003, −0.0016, −0.0019, −0.0003, and −0.0025 for the JSCE model, the ACI model, the CSA model, the CCCM model, the EE-b model, and the Ju model, respectively. The safety of the selected models decreases with the increase in the depth, except for the JSCE. The best fit line for the SR value that was calculated using the EE-b model is the lowest, thus, it is the most consistent with respect to the depth. However, using the ACI model resulted in the highest SR value, thus, it is the least consistent one. This could be due to the ACI model not having a size effect factor.

7.2. Concrete Compressive Strength

Figure 7 shows the SR value that was calculated using the ACI model, the JSCE model, the CSA model, the CCCM model, the Ju model, and the EE-b model versus the concrete compressive strength. In addition, the best fit line was plotted, whose slope was 0.0019, 0.0046, 0.0174, −0.0031, −0.0017, and −0.0027 for the JSCE model, the ACI model, the CSA model, the CCCM model, the EE-b model, and the Ju model, respectively. The safety of the CCCM model, the EE-b model, and the Ju model decreases with the increase in the concrete compressive strength. On the other hand, the safety of the JSCE model, the ACI model, and the CSA model increases with the increase in the concrete compressive strength. The best fit line for the SR value that was calculated using the EE-b model is the lowest; thus, it is the most consistent with respect to the concrete compressive strength. However, using the CSA model resulted in the highest SR value; thus, it is the least consistent one.

7.3. Flexure Reinforcment Ratio

Figure 8 shows the SR value that was calculated using the ACI model, the JSCE model, the CSA model, the CCCM model, the Ju model, and the EE-b model versus the flexure reinforcement ratio. In addition, the best fit line was plotted, whose slope was 0.2529, −0.6244, −0.2229, −0.0328, −0.1817, and −0.1844 for the JSCE model, the ACI model, the CSA model, the CCCM model, the EE-b model, and the Ju model, respectively. The safety of the selected models decreases with the increase in flexure reinforcement ratio, except for the JSCE model. The best fit line for the SR value that was calculated using the CCCM model is the lowest; thus, it is the most consistent with respect to the flexure reinforcement ratio. However, using the ACI model resulted in the highest SR value; thus, it is the least consistent one. This could be due to the ACI model not including the flexure reinforcement ratio in the model.

7.4. Young’s Modulus

Figure 9 shows the SR value that was calculated using the ACI model, the JSCE model, the CSA model, the CCCM model, the Ju model, and the EE-b model versus the Young’s modulus. In addition, the best fit line was plotted, whose slope was 0.0075, 0.0012, 0.0013, −0.002, −0.0011, and 0.0002 for the JSCE model, the ACI model, the CSA model, the CCCM model, the EE-b model, and the Ju model, respectively. The safety of selected models increases with the increase in Young’s modulus, except for the CCCM model and the EE-b model. The best fit line for the SR value that was calculated using the Ju model is the lowest; thus, it is the most consistent with respect to the Young’s modulus. However, using the JSCE model resulted in the highest SR value; thus, it is the least consistent one.

7.5. Depth-to-Control Perimeter Ratio

Figure 10 shows the SR value that was calculated using the ACI model, the JSCE model, the CSA model, the CCCM model, the Ju model, and the EE-b model versus the depth-to-control perimeter ratio. In addition, the best fit line was plotted; whose slope was 8.5935, 13.86, 6.8699, −2.4433, −0.8117, and −1.6327 for the JSCE model, the ACI model, the CSA model, the CCCM model, the EE-b model, and the Ju model, respectively. The safety of the CCCM model, the EE-b model, and the Ju model decreases with the increase in the depth-to-control perimeter ratio. On the other hand, the safety of the JSCE model, the ACI model, and the CSA model increases with the increase in the depth-to-control perimeter ratio. The best fit line for the SR value that was calculated using the EE-b model is the lowest; thus, it is the most consistent with respect to the depth-to-control perimeter ratio. However, using the ACI model resulted in the highest SR value; thus, it is the least consistent one. This could be because the ACI model does not include the effect of this parameter.

7.6. Shear Span-to-Depth Ratio

Figure 11 shows the SR value that was calculated using the ACI model, the JSCE model, the CSA model, the CCCM model, the Ju model, and the EE-b model versus the shear span-to-effective depth ratio. In addition, the best fit line was plotted, whose slope was −0.0507, −0.0475, −0.0224, 0.1353, 0.023, and 0.0213 for the JSCE model, the ACI model, the CSA model, the CCCM model, the EE-b model, and the Ju model, respectively. The safety of the JSCE model, the ACI model, the CSA model decreases with the increase in the shear span-to-effective depth ratio. On the other hand, the safety of the CCCM model, the EE-b model, and the Ju model increases with the increase in the shear span-to-effective depth ratio. The best fit line for the SR value that was calculated using the CSA model, the Ju model, and the EE-b model is the lowest; thus, they are the most consistent with respect to the shear span-to-effective depth ratio. However, using the CCCM model resulted in the highest; thus, it is the least consistent one.

8. Future Research

Several areas of potential for future research studies were identified as follows:

  • Experimental testing of high strength slabs with a compressive strength of more than 45 MPa;

  • Experimental testing of ultra-high-performance concrete slabs with a compressive strength of more than 100 MPa;

  • Experimental testing of non-slender concrete slabs with a shear span-to-depth ratio of less than 2.5;

  • Reliability-based analysis for the safety of the design which includes the variability in the loads, the geometry, the material, and the construction;

  • A more reliable and consistent mechanically based model that makes physical sense, while being simple in its design.

9. Conclusions

The accuracy of twenty-one selected methods to predict the two-way shear strength of the concrete slabs was assessed. Each method’s ability to predict the two-way strength of concrete slabs without shear reinforcement was studied by comparing predictions against their measured strength from an extensive experimental database comprising a total of 248 slabs from over 50 research studies. Several statistical measures were applied, and the effect of the various basic variables was discussed. The following conclusions were reached:

  • The JSCE, the ACI, the H models are over-conservative, with an average value of 2.71, 2.18, and 2.16, respectively. The Zg, the EE-b, the Ju, the A models are more consistent with respect to other models, where the coefficient of variation value was 35%, 35%, 36%, and 36%, respectively.

  • The ACI model is the least consistent with respect to the size effect, the dowel action, and the depth-to-control perimeter ratio. This could be due to the fact that the ACI model does not consider these factors in the model.

  • The EE-b model is the most consistent with respect to size effect, concrete compressive strength, depth-to-control perimeter ratio, and the shear span-to-depth ratio. This is because of it using experimentally observed behavior as well as it being based on mechanical bases.

Author Contributions

Conceptualization, F.A.; methodology M.A. (Majed Alzara); software, T.I.; validation, A.M.Y.; formal analysis, M.A. (Mohamed AbdelMongy); investigation, A.F.D. and M.A. (Mohamed AbdelMongy); resources A.F.D. and F.A.; data curation, A.M.Y.; writing—original draft preparation, A.M.Y. and M.A. (Mohamed AbdelMongy); writing—review and editing, A.F.D. and T.I.; visualization, F.A.; supervision, A.F.D. and F.A. All authors have read and agreed to the published version of the manuscript.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

All data are available within the manuscript.

Conflicts of Interest

The authors declare no conflict of interest.

Funding Statement

This research received no external funding.

Footnotes

Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

References

  • 1.Lu X., Guan H., Sun H., Li Y., Zuo L. A preliminary analysis and discussion of the condominium building collapse in surfside. Front. Struct. Civ. Eng. 2021;15:1097–1110. doi: 10.1007/s11709-021-0766-0. [DOI] [Google Scholar]
  • 2.Deifalla A. Punching shear strength and deformation for FRP-reinforced concrete slabs without shear reinforcement. Case Stud. Constr. Mater. 2022;16:e00925. doi: 10.1016/j.cscm.2022.e00925. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 3.Deifalla A. Strength and Ductility of Lightweight Reinforced Concrete Slabs under Punching Shear. Structures. 2020;27:2329–2345. doi: 10.1016/j.istruc.2020.08.002. [DOI] [Google Scholar]
  • 4.Deifalla A. A mechanical model for concrete slabs subjected to combined punching shear and in-plane tensile forces. Eng. Struct. Elsevier. 2021;231:111787. doi: 10.1016/j.engstruct.2020.111787. [DOI] [Google Scholar]
  • 5.Deifalla A. A strength and deformation model for prestressed lightweight concrete slabs under two-way shear. Adv. Struct. Eng. 2021;24:3144–3155. doi: 10.1177/13694332211020408. [DOI] [Google Scholar]
  • 6.FIB . FRP Reinforcement in RC Structures, Technical Report Prepared by a Working Party of Task Group 9.3: Fib Bulletin 40. FIB; Cham, Switzerland: 2007. [Google Scholar]
  • 7.Yooprasertchai E., Tiawilai Y., Wittayawanitchai T., Angsumalee J., Joyklad P., Hussain Q. Effect of Shape, Number, and Location of Openings on Punching Shear Capacity of Flat Slabs. Buildings. 2021;11:484. doi: 10.3390/buildings11100484. [DOI] [Google Scholar]
  • 8.Wu L., Huang T., Tong Y., Liang S. A Modified Compression Field Theory Based Analytical Model of RC Slab-Column Joint without Punching Shear Reinforcement. Buildings. 2022;12:226. doi: 10.3390/buildings12020226. [DOI] [Google Scholar]
  • 9.Bywalski C., Drzazga M., Kamiński M., Kaźmierowski M. A New Proposal for the Shear Strength Prediction of Beams Longitudinally Reinforced with Fiber-Reinforced Polymer Bars. Buildings. 2020;10:86. doi: 10.3390/buildings10050086. [DOI] [Google Scholar]
  • 10.Ebid A., Deifalla A. Prediction of Shear Strength of FRP Reinforced Beams with and Without Stirrups Using (GP) Technique. Ain Shams Eng. J. Elsevier. 2021;12:2493–2510. doi: 10.1016/j.asej.2021.02.006. [DOI] [Google Scholar]
  • 11.Ali A.H., Mohamed H.M., Chalioris C.E., Deifalla A. Evaluation of the shear design equations of FRP-reinforced concrete beams without shear reinforcement. Eng. Struct. 2021;235:112017. doi: 10.1016/j.engstruct.2021.112017. [DOI] [Google Scholar]
  • 12.Hassan M.M., Deifalla A. Evaluating the new CAN/CSA-S806-12 torsion provisions for concrete beams with FRP reinforcements. Mater. Struct. 2015;49:2715–2729. doi: 10.1617/s11527-015-0680-9. [DOI] [Google Scholar]
  • 13.Deifalla A. Torsional Behavior of Rectangular and Flanged concrete beams with FRP. J. Struct. Eng. ASCE. 2015;141:04015068. doi: 10.1061/(ASCE)ST.1943-541X.0001322. [DOI] [Google Scholar]
  • 14.Deifalla A., Khali M.S., Abdelrahman A. Simplified Model for the Torsional Strength of Concrete Beams with GFRP Stirrups. Compos. Constr. ASCE. 2015;19:04014032. doi: 10.1061/(ASCE)CC.1943-5614.0000498. [DOI] [Google Scholar]
  • 15.Deifalla A., Hamed M., Saleh A., Ali T. Exploring GFRP bars as reinforcement for rectangular and L-shaped beams subjected to significant torsion: An experimental study. Eng. Struct. 2014;59:776–786. doi: 10.1016/j.engstruct.2013.11.027. [DOI] [Google Scholar]
  • 16.Elmeligy O., El-Nemr A., Deifalla A. Reevaluating the Modified Shear Provision of CAN/CSA S806-12 for Concrete Beams Reinforced with FRP Stirrups; Proceedings of the AEI Conference ASCE; Oklahoma City, OK, USA. 11–13 April 2017. [Google Scholar]
  • 17.Deifalla A. Refining the Torsion Design of Fibered Concrete Beams Reinforced with FRP using Multi-variable Non-linear Regression Analysis for Experimental Results. Eng. Struct. Elsevier. 2021;224:111394. doi: 10.1016/j.engstruct.2020.111394. [DOI] [Google Scholar]
  • 18.Deifalla A.F., Zapris A.G., Chalioris C.E. Multivariable Regression Strength Model for Steel Fiber-Reinforced Concrete Beams under Torsion. Materials. 2021;14:3889. doi: 10.3390/ma14143889. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 19.Kuchma D., Wei S., Sanders D., Belarbi A., Novak L. The development of the one-way shear design provisions of ACI 318-19. ACI Struct. J. 2019;116:285–296. doi: 10.14359/51716739. [DOI] [Google Scholar]
  • 20.Collins M.P. Evaluation of Shear Design Procedures for Concrete Structures. Canadian Standards Association; Toronto, ON, Canada: 2001. A CSA Technical Committee Reinforced Concrete Design Report. [Google Scholar]
  • 21.Gardner N.J. Relationship of the punching shear capacity of reinforced concrete slabs with concrete strength. ACI Struct. J. 1990;87:66–71. [Google Scholar]
  • 22.JSCE . In: Recommendation for Design and Construction of Concrete Structures Using Continuous Fiber Reinforcing Materials. Machida A., editor. Japan Society of Civil Engineers; Tokyo, Japan: 1997. p. 325. (Concrete Engineering Series 23). [Google Scholar]
  • 23.El-Ghandour A.W., Pilakoutas K., Waldron P. Punching shear behavior of fiber reinforced polymers reinforced concrete flat slabs: Experimental study. J. Compos. Constr. 2003;7:258–265. doi: 10.1061/(ASCE)1090-0268(2003)7:3(258). [DOI] [Google Scholar]
  • 24.Matthys S., Taerwe L. Concrete slabs reinforced with FRP grids. II: Punching resistance. J. Compos. Constr. ASCE. 2000;4:154–161. doi: 10.1061/(ASCE)1090-0268(2000)4:3(154). [DOI] [Google Scholar]
  • 25.Ospina C.E., Alexander S.D.B., Cheng J.J.R. Punching of two- way slabs with fiber-reinforced polymer reinforcing bars or grids. ACI Struct. J. 2003;100:589–598. [Google Scholar]
  • 26.Zaghloul A., Razaqpur A. Punching shear behavior of CFRP reinforced concrete flat plates; Proceedings of the International Conference on Composites in Construction; Sydney, Australia. 22–25 June 2003; pp. 1–726. [Google Scholar]
  • 27.Jacobson D.A., Bank L.C., Oliva M.G., Russel J.S. Punching Shear Capacity of Double Layer FRP Grid Reinforced Slabs. ACI, Specs Publication. SP; Farmington Hills, MI, USA: 2005. pp. 230–249, 857–876. [Google Scholar]
  • 28.ACI; Farmington Hills, MI, USA: 2015. Guide for the Design and Construction of Concrete Reinforced with FRP Bars (ACI 440.1R-15) [Google Scholar]
  • 29.El-Gamal S., El-Salakawy E., Benmokrane B. Behaviour of Concrete Bridge Deck Slabs Reinforced with Fiber-Reinforced Polymer Bars Under Concentrated Loads. ACI Struct. J. 2005;102:727–735. [Google Scholar]
  • 30.Zhang Q. Master’s Thesis. Memorial University of Newfoundland; St. John’s, NF, Canada: 2006. Behaviour of Two-way Slabs Reinforced with CFRP Bars. [Google Scholar]
  • 31.Zhang Q., Marzouk H., Hussein A. A preliminary study of high-strength concrete two-way slabs reinforced with GFRP bars; Proceedings of the 33rd CSCE Annual Conference: General Conference and International History Symposium CSCE; Toronto, ON, Canada. 2–4 June 2005. [Google Scholar]
  • 32.Theodorakopoulos D.D., Swamy R.N. Analytical model to predict punching shear strength of FRP-reinforced concrete flat slabs. ACI Struct. J. 2007;104:257–266. [Google Scholar]
  • 33.Design and Construction of Building Structures with Fiber Reinforced Polymers (CAN/CSA S806-12) Canadian Standards Association; Rexdale, ON, Canada: 2012. [Google Scholar]
  • 34.Nguyen-Minh L., Rovnak M. Punching-Shear Resistance of Interior GFRP Reinforced Slab-Column Connection. ASCE J. Compos. Constr. 2013;17:2–13. doi: 10.1061/(ASCE)CC.1943-5614.0000324. [DOI] [Google Scholar]
  • 35.Hassan M., Fam A., Benmokrane B. A new punching shear design formula for frp-reinforced interior slab-column connections; Proceedings of the 7th International Conference on Advanced Composite Materials in Bridges and Structures; Vancouver, BC, Canada. 22–24 August 2016. [Google Scholar]
  • 36.Kara I.F., Sinani B. Prediction of Punching Shear Capacity of Two-Ways FRP Reinforced Concrete Slabs. Int. J. Bus. Technol. 2017;5:57–63. doi: 10.33107/ijbte.2017.5.2.03. [DOI] [Google Scholar]
  • 37.Oller E., Kotynia R., Marí A. High Tech Concrete: Where Technology and Engineering Meet. Springer; Cham, Switzerland: 2018. Assessment of the existing formulations to evaluate shear-punching strength in RC slabs with FRP bars without transverse reinforcement. [DOI] [Google Scholar]
  • 38.Marí A., Bairán J., Cladera A., Oller E., Ribas C. Shear-flexural strength mechanical model for the design and assessment of reinforced concrete beams. Struct. Infrastruct. Eng. 2015;11:1399–1419. doi: 10.1080/15732479.2014.964735. [DOI] [Google Scholar]
  • 39.Hemzah S.A., Al-Obaidi S., Salim T. Punching Shear Model for Normal and High-Strength Concrete Slabs Reinforced with CFRP or Steel Bars. Jordan J. Civ. Eng. 2019;13:250–268. [Google Scholar]
  • 40.El-Gendy M.G.S., El-Salakawy E.F. Assessment of Punching Shear Design Models for FRP-RC Slab–Column Connections. J. Compos. Constr. 2020;24:04020047. doi: 10.1061/(ASCE)CC.1943-5614.0001054. [DOI] [Google Scholar]
  • 41.Ju M., Ju J., Sim J.W. A new formula of punching shear strength for fiber reinforced polymer (FRP) or steel reinforced two-way concrete slabs. Compos. Struct. 2021;258:113471. doi: 10.1016/j.compstruct.2020.113471. [DOI] [Google Scholar]
  • 42.Alrudaini T.M.S. A rational formula to predict punching shear capacity at interior columns connections with RC flat slabs reinforced with either steel or FRP bars but without shear reinforcement. Structures. 2022;37:56–68. doi: 10.1016/j.istruc.2021.12.077. [DOI] [Google Scholar]
  • 43.Shen Y., Sun J., Liang S. Interpretable Machine Learning Models for Punching Shear Strength Estimation of FRP Reinforced Concrete Slabs. Crystals. 2022;12:259. doi: 10.3390/cryst12020259. [DOI] [Google Scholar]
  • 44.Yooprasertchai E., Dithaem R., Arnamwong T., Sahamitmongkol R., Jadekittichoke J., Joyklad P., Hussain Q. Remediation of Punching Shear Failure Using Glass Fiber Reinforced Polymer (GFRP) Rods. Polymers. 2021;13:2369. doi: 10.3390/polym13142369. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 45.Ahmad H.S., Zia P., Yu T.J., Xie Y. Punching shear tests of slabs reinforced with 3-dimensional carbon fiber fabric. Concr. Int. 1993;16:36–41. [Google Scholar]
  • 46.Banthia N., Al-Asaly M., Ma S. Behavior of Concrete Slabs Reinforced with Fiber-Reinforced Plastic Grid. ASCE J. Mater. Civ. Eng. 1995;7:252–257. doi: 10.1061/(ASCE)0899-1561(1995)7:4(252). [DOI] [Google Scholar]
  • 47.Bank L., Xi Z. Proceedings of the Non-Metallic (FRP) Reinforcement for Concrete Structures. CRC Press; Boca Raton, FL, USA: 1995. Punching shear behavior of pultruded FRP grating reinforced concrete slabs; pp. 360–367. [Google Scholar]
  • 48.Louka H.J. Master’s Thesis. University of Manitoba; Winnipeg, MB, Canada: 1999. Punching Behavior of a Hybrid Reinforced Concrete Bridge Deck. [Google Scholar]
  • 49.Rahman A.H., Kingsley C.Y., Kobayashi K. Service and ultimate load behavior of bridge deck reinforced with carbon FRP grid. J. Compos. Constr. 2000;4:16–23. doi: 10.1061/(ASCE)1090-0268(2000)4:1(16). [DOI] [Google Scholar]
  • 50.Hassan T., Abdelrahman A., Tadros G., Rizkalla S. Fibre reinforced polymer reinforcing bars for bridge decks. Can. J. Civ. Eng. 2000;27:839–849. doi: 10.1139/l99-098. [DOI] [Google Scholar]
  • 51.Khanna O., Mufti A., Bakht B. Experimental investigation of the role of reinforcement in the strength of concrete deck slabs. Can. J. Civil. Eng. 2000;27:475–480. doi: 10.1139/l99-094. [DOI] [Google Scholar]
  • 52.Hussein A., Rashid I., Benmokrane B. Two-way concrete slabs reinforced with GFRP bars; Proceedings of the 4th International Conference on Advanced Composite Materials in Bridges and Structures CSCE; Calgary, AB, Canada. 20–23 July 2004. [Google Scholar]
  • 53.Tom E.E. Master’s Thesis. Memorial University of Newfoundland; St. John’s, NF, Canada: 2007. Behavior of Two-Way Slabs Reinforced with GFRP Bars; p. 169. [Google Scholar]
  • 54.Zaghloul A. Ph.D. Thesis. Department of Civil and Environmental Engineering, Carleton University; Ottawa, ON, Canada: 2007. Punching Shear Strength of Interior and Edge Column Slab Connections in CFRP Rein-forced Flat Plate Structures Transferring Shear and Moment. [Google Scholar]
  • 55.El-Gamal S., El-Salakawy E., Benmokrane B. Influence of reinforcement on the behaviour of concrete bridge deck slabs reinforced with FRP bars. J. Compos. Constr. ASCE. 2007;11:449–458. doi: 10.1061/(ASCE)1090-0268(2007)11:5(449). [DOI] [Google Scholar]
  • 56.Zaghloul E., Mahmoud Z., Salama T. Punching behavior and strength of two-way concrete slabs reinforced with glass fiber reinforced polymer (GFRP) rebars; Proceedings of the Structural Composites for Infrastructure Applications; Hurghada, Egypt. 23–28 May 2008. [Google Scholar]
  • 57.Lee J.H., Yoon Y.S., Cook W.D., Mitchell D. Improving punching shear behavior of glass fiber-reinforced polymer rein- forced slabs. ACI Struct. J. 2009;106:427–434. [Google Scholar]
  • 58.Zhu H., Zhang Y., Gao D., Xiao Z. Deformation Behavior of Concrete Two-Way Slabs Reinforced with BFRP Bars Subjected to Eccentric Loading; Proceedings of the CICE 2010: The 5th International Conference on FRP Composites in Civil Engineering; Beijing, China. 27–29 September 2010. [Google Scholar]
  • 59.Min K.H., Yang J.M., Yoo D.Y., Yoon Y.S. Flexural and Punching Performances of FRP and Fiber Reinforced Concrete on Impact Loading; Proceedings of the CICE 2010–The 5th International Conference on FRP Composites in Civil Engineering; Beijing, China. 27–29 September 2010. [Google Scholar]
  • 60.Xiao Z. Master’s Thesis. Zhengzhou University; Zhengzhou, China: 2010. Expremental Study on Two-Way Concrete Slab Subjected to Punching Shear. [Google Scholar]
  • 61.Bouguerra K., Ahmed E.A., El-Gamal S., Benmokrane B. Testing of full-scale concrete bridge deck slabs reinforced with fiber-reinforced polymer (FRP) bars. Constr. Build. Mater. 2011;25:3956–3965. doi: 10.1016/j.conbuildmat.2011.04.028. [DOI] [Google Scholar]
  • 62.Zhu H.Y., Wang J.L. Plastic analysis on punching shear capacity of two-way BFRP rebar reinforced concrete slabs under central concentrated load. J. Zhengzhou Univ. (Eng. Sci.) 2012;33:1–5. (In Chinese) [Google Scholar]
  • 63.El-gendy M., El-Salakawy E. Punching Shear Behaviour of GFRP-RC Edge Slab-Column Connections; Proceedings of the 7th International Conference on FRP Composites in Civil Engineering; Vancouver, BC, Canada. 20–22 August 2014; pp. 1–6. [Google Scholar]
  • 64.Tharmarajah G., Taylor E.S., Cleland J.D., Robinso D. Proceedings of the Institution of Civil Engineers. Bridge Engineering. Volume 168. ICE Publishing; London, UK: 2015. Corrosion-resistant FRP reinforcement for bridge deck slabs; pp. 208–217. [DOI] [Google Scholar]
  • 65.Mostafa A. Master’s Thesis. Manitoba University; Winnipeg, MB, Canada: 2016. Punching Shear Behavior of GFRP-RC Slab-Column Edge Connections with High Strength Concrete and Shear Reinforcement; p. 51. [Google Scholar]
  • 66.Fareed E., Ahmed E.A., Benmokrane B. Experimental Testing WMCAUS IOP Conference Series: Materials Science and Engineering. IOP Publishing; Bristol, UK: 2016. p. 32064. [DOI] [Google Scholar]
  • 67.Gouda A., El-Salakawy E. Behavior of GFRP-RC Interior Slab-Column Connections with Shear Studs and High-Moment Transfer. J. Compos. Constr. 2016;20:04016005. doi: 10.1061/(ASCE)CC.1943-5614.0000663. [DOI] [Google Scholar]
  • 68.Gouda A., El-Salakawy E. Punching Shear Strength of GFRPRC Interior Slab-Column Connections Subjected to Moment Transfer. J. Compos. Constr. ASCE. 2016;20:04015037. doi: 10.1061/(ASCE)CC.1943-5614.0000597. [DOI] [Google Scholar]
  • 69.Oskouei A.V., Kivi M.P., Araghi H., Bazli M. Experimental study of the punching behavior of GFRP reinforced lightweight concrete footing. Mater. Struct. 2017;50:256. doi: 10.1617/s11527-017-1127-2. [DOI] [Google Scholar]
  • 70.Abduljaleel M.T., Mahmoud A.S., Yousif A. Experimental investigation of two-way concrete slabs with openings reinforced with glass fiber reinforced polymer bars. J. Eng. Sci. Technol. 2017;12:889–912. [Google Scholar]
  • 71.Ju M., Park K., Park A.C. Punching Shear Behavior of Two-Way Concrete Slabs Reinforced with Glass-Fiber-Reinforced Polymer (GFRP) Bars. Polymers. 2018;10:893. doi: 10.3390/polym10080893. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 72.Hussein A.F., El-Salakawy E. Punching Shear Behavior of Glass Fiber-Reinforced Polymer-Reinforced Concrete Slab-Column Interior Connections. ACI Struct. J. 2018;115:1075–1088. doi: 10.14359/51702134. [DOI] [Google Scholar]
  • 73.Salama A.E., Hassan M., Benmokrane A.B. Effectiveness of Glass Fiber-Reinforced Polymer Stirrups as Shear Reinforcement in Glass Fiber-Reinforced Polymer- Reinforced Concrete Edge Slab-Column Connections. ACI Struct. J. 2019;116:165–180. doi: 10.14359/51716757. [DOI] [Google Scholar]
  • 74.Eladawy B., Hassan M., Benmokrane B. Experimental Study of Interior Glass Fiber-Reinforced Polymer-Reinforced Concrete Slab-Column Connections under Lateral Cyclic Load. ACI Struct. J. 2019;116:165–180. doi: 10.14359/51716803. [DOI] [Google Scholar]
  • 75.Gu S. Master’s Thesis. Zhejiang University of Technology; Zhejiang, China: 2020. Study on The Punching Shear Behavior of FRP Reinforced Concrete Slabs Subjected to Concentric Loading. [Google Scholar]
  • 76.Zhou X. Master’s Thesis. Zhejiang University of Technology; Zhejiang, China: 2020. Expremental Study on the Punching Shear Behavior of Square GFRP Reinforced Concrete Slabs. [Google Scholar]
  • 77.Eladawy M., Hassan M., Benmokrane B., Ferrier E. Lateral cyclic behavior of interior two-way concrete slab–column connections reinforced with GFRP bars. Eng. Struct. 2020;209:109978. doi: 10.1016/j.engstruct.2019.109978. [DOI] [Google Scholar]
  • 78.Huang Z., Zhao Y., Zhang J., Wu Y. Punching shear behavior of concrete slabs reinforced with CFRP grids. Structures. 2020;26:617–625. doi: 10.1016/j.istruc.2020.04.047. [DOI] [Google Scholar]
  • 79.Salama A.E., Hassan M., Benmokrane B. Punching-Shear Behavior of Glass Fiber-Reinforced Polymer-Reinforced Concrete Edge Column-Slab Connections: Experimental and Analytical Investigations. ACI Struct. J. 2021;118:147–160. [Google Scholar]
  • 80.AlHamaydeh M., Orabi M.A. Punching Shear Behavior of Synthetic Fiber–Reinforced Self-Consolidating Concrete Flat Slabs with GFRP Bars. J. Compos. Constr. 2021;25:04021029. doi: 10.1061/(ASCE)CC.1943-5614.0001131. [DOI] [Google Scholar]
  • 81.Mohmmad S.H., Gülsan M.E., Çevik A. Punching shear behaviour of geopolymer concrete two-way slabs reinforced by FRP bars under monotonic and cyclic loadings. Adv. Struct. Eng. 2022;25:453–472. doi: 10.1177/13694332211052349. [DOI] [Google Scholar]
  • 82.Shill S., Garcez E., Al-Ameri R., Subhani M. Performance of Two-Way Concrete Slabs Reinforced with Basalt and Carbon FRP Rebars. J. Compos. Sci. 2022;6:74. doi: 10.3390/jcs6030074. [DOI] [Google Scholar]
  • 83.Building Code Requirements for Structural Concrete: (ACI 318-19) and Commentary. American Concrete Institute; Farmington Hills, MI, USA: 2019. [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Data Availability Statement

All data are available within the manuscript.


Articles from Polymers are provided here courtesy of Multidisciplinary Digital Publishing Institute (MDPI)

RESOURCES