Skip to main content
Annals of Medicine logoLink to Annals of Medicine
. 2022 Sep 22;54(1):2617–2626. doi: 10.1080/07853890.2022.2125574

Bioequivalence and safety evaluation of two preparations of metformin hydrochloride sustained-release tablets (Boke® and Glucophage®-XR) in healthy Chinese volunteers: a randomized phase I clinical trial

Ming-Li Sun a, Chen Liu a, Hai-Hong Bai a, Ya-Li Wei a, Wei Zhang a, Hui-Juan Liu a, Yin-Juan Li a, Long Liu a, Yu Wang a, Yuan-Xv Tong a, Qian Gao b, Qian-Ying Liu c, Xinghe Wang a,
PMCID: PMC9521607  PMID: 36135935

Abstract

Background

As per the National Medical Products Administration (NMPA) requirements, the quality and efficacy of generic drugs must be consistent with those of the innovator drug. We aimed to evaluate the bioequivalence and safety of generic metformin hydrochloride sustained-release (MH-SR) tablets (Boke®) developed by Beijing Wanhui Double-crane Pharmaceutical Co. Ltd., China and the innovator product metformin hydrochloride extended-release tablets (Glucophage®-XR) manufactured by Bristol-Myers Squibb Company, New York, NY, in healthy Chinese volunteers.

Materials and methods

We performed a bioequivalence and safety assessment of MH-SR (500 mg/tablet) and Glucophage®-XR (500 mg/tablet) tablets in a randomized, open-label, two-period, two-sequence crossover, single-dose oral study in 48 healthy Chinese adult participants under fasting conditions (Chinese Clinical Trial Registration No. CTR20171306). The washout period was seven days. Bioequivalence (80.00–125.00%) was assessed using adjusted geometric mean ratios (GMRs) and two-sided 90% confidence intervals (CIs) of the area under the curve (AUC) and maximum concentration (Cmax) for each component.

Results

The 90% CIs of the test/reference preparation for key pharmacokinetic parameters were 97.36–108.30% for AUC0→t, 97.26–108.09% for AUC0→∞ and 96.76–111.37% for Cmax. No severe adverse events (AEs) were observed. However, 38 adverse drug reactions (ADRs) occurred, including metabolic or nutritional conditions (n = 8), infections (n = 2), gastrointestinal conditions (n = 10) and abnormal inspection (n = 18). No significant difference was observed between MH-SR (23 ADRs, 10 participants) and Glucophage®-XR (15 ADRs, 12 participants) (p = .500). Bioequivalence was concluded since the 90% CIs of the main pharmacokinetic parameters were within the equivalence interval (80.00–125.00%).

Conclusions

MH-SR (500 mg/tablet) and Glucophage®-XR (500 mg/tablet) were found to be bioequivalent and safe under fasting conditions in healthy Chinese participants. Thus, the market demand for MH-SR tablets (500 mg/tablet) can be met using the generic alternative.

KEY MESSAGES

  • Generic MH-SR tablets (500 mg, Beijing Wanhui Double-crane Pharmaceutical Co. Ltd., Beijing, China) and innovator MH-SR tablets (Glucophage®-XR, 500 mg, Bristol-Myers Squibb Company, New York, NY, USA) were bioequivalent and safe in healthy Chinese volunteers under single-dose administration and fasting conditions.

  • The main goal of this study is to support an increase in the supply of MH-SR tablets in China by proving the efficacy and safety of a generic alternative.

  • Although no sugar was administered in the BE trial of the MH-SR tablets under fasting conditions, no hypoglycaemic event occurred. The method used in this study is expected to serve as a reference for BE studies of different MH-SR formulations.

Keywords: Bioequivalence, crossover trials, metformin hydrochloride, pharmacokinetics, fasting conditions

Introduction

Diabetes is a serious threat to human health, particularly in China. Globally, 537 million adults (20–79 years) are living with diabetes (1 in 10), and this number is predicted to rise to 643 million by 2030 and 783 million by 2045 [1]. In China, the estimated prevalence of diabetes in 2018 was 12.4% [95% confidence interval (CI), 11.8–13.0%] [2]. Metformin, a double guanidine drug, is the first-line treatment for type 2 diabetes [3,4].

Metformin is an amphoteric compound with pKa values of 2.8 and 11.5. The absolute oral bioavailability of metformin is 50–60%, and the gastrointestinal absorption is apparently complete within 6 h of ingestion. Metformin is rapidly distributed without any plasma-protein binding, and it undergoes renal excretion owing to its high hydrophilicity [5,6]. The most frequent adverse events (AEs) associated with metformin are gastrointestinal [7–9].

Compared with metformin hydrochloride tablets, metformin hydrochloride sustained-release (MH-SR) tablets are characterized by sustained drug release, long-lasting efficacy, decreased frequency of medication, fewer side effects and enhanced patient compliance [10].

Generic MH-SR tablets are crucial for the vast Chinese pharmaceutical market because it addresses the limited supply and high prices of the innovator MH-SR [11]. China joined the International Council for Harmonization of Technical Requirements for Pharmaceuticals for Human Use (ICH) in 2017 [12]. According to the requirements of the National Medical Products Administration (NMPA), generic drugs must be evaluated for consistency in quality and efficacy compared with the innovator drug [13].

The purpose of this study was to evaluate the bioequivalence and safety of generic MH-SR tablets (trade name: Boke®) developed by Beijing Wanhui Double-crane Pharmaceutical Co. Ltd., China and the innovator product, metformin hydrochloride extended-release (trade name: Glucophage®-XR) manufactured by Bristol-Myers Squibb Company, New York, NY, USA. The study was conducted under single-dose administration and fasting conditions in healthy Chinese volunteers.

Materials and methods

Study products

The study products were Boke® (500 mg/tablet), the test preparation, and Glucophage®-XR (500 mg/tablet), the reference preparation. They were provided by the study sponsor, Beijing Wanhui Double-crane Pharmaceutical Co. Ltd., Beijing, China. Characteristics of the study products are presented in Table 1.

Table 1.

Characteristics of the study products.

  Test product Reference product
Ingredients MH-SR MH-XR
Dosage 500mg per tablet 500mg per tablet
Trade name Boke® Glucophage®-XR
Lot number 1160513 5B82400
Content 98.9% 97.3%
Manufacturing date 16 May 2016 01 February 2015
Expiry date 30 April 2019 31 January 2018
Manufacturer Beijing Wanhui Double-crane Pharmaceutical Co., Ltd., China Bristol-Myers Squibb Company, USA

Study design

Two MH-SR formulations were evaluated for bioequivalence and safety in 48 healthy Chinese volunteers under fasting conditions. The study was designed as a single-centre, randomized, open-label, two-period, two-sequence crossover study, involving the administration of a single dose of 500 mg. The clinical trial was conducted at the Clinical Trial Centre of Beijing Shijitan Hospital, affiliated with the Capital Medical University, China, from 29 November 2017 to 16 April 2018. The study protocol and related documents were reviewed and approved by the Institutional Review Board of Beijing Shijitan Hospital (approval no. 2017Y94) on 16 October 2017. The clinical trial complied with the Declaration of Helsinki, Good Clinical Practice Guidelines of the ICH, Good Laboratory Practice, Pharmaceutical Administration Law, and other local laws and regulations. This clinical trial was registered in the Chinese Clinical Trial Registry (Registration No. CTR20171306). Written informed consent was obtained from all the participants prior to the study. All mandatory laboratory health and safety procedures have been complied with in the course of conducting any experimental work reported in this report.

Participants

Participants were screened 1–7 d before administration. Demographic data, medical history (information provided by participants and then collected from the Hospital Information System by researchers), and smoking history of the volunteers were collected. The following examinations were conducted: vital signs (blood pressure, pulse, breathing and body temperature), 12-lead electrocardiogram (ECG), physical examination and clinical laboratory examination (routine urine and blood tests and blood biochemistry), serum virology tests (hepatitis B virus surface antigen, hepatitis C virus antibody and Treponema pallidum antibody), and human immunodeficiency virus antibody test. Additionally, women of childbearing age underwent a blood pregnancy test.

The study enrolled healthy Chinese adult volunteers aged 18 years and older with a body mass index of 19.0–28.0 kg/m2, male body weight ≥50 kg, and female body weight 0–28 kg. The inclusion criteria were as follows: individuals not addicted to drugs, alcohol or smoking and those without comorbid conditions, including cardiovascular, hepatic, renal, digestive tract, respiratory, neurological and metabolic abnormalities. The inclusion of the participants was based on the clinical judgement of the investigators, according to medical history and clinical examination. A negative pregnancy test prior to enrolment was an essential condition for including female participants, and they were required to use adequate contraception until 6 months after the second administration. The key exclusion criteria were as follows: consumption of any drug within 2 weeks before the clinical trial, a history of acupuncture syncope, difficulty in collecting venous blood, and blood loss or blood donation of >400 mL within 3 months before the trial.

Withdrawal criteria: The investigator had the right to withhold a participant from further dosing if the participant experienced AEs or symptoms or conditions listed in the exclusion criteria during the study or if the participants decided to drop out during the trial under any circumstances.

Drug administration and blood sample collection

The predesigned random allocation sequence was generated using SAS version 9.2 (SAS Institute, Cary, NC, USA) by a statistician, and the random seed number was saved for verification. Forty-eight healthy Chinese participants were randomly assigned to one of the two dosing-order subgroups, reference-test (R-T) and test-reference (T-R) at a 1:1 ratio, using a random allocation sequence. After overnight fasting for 10 h, each participant was administered a single dose of either preparation of MH-SR (T/R) at 500 mg with 240 mL of water, according to the study protocol. Lunch and dinner were served 4 and 10 h after drug administration, respectively (Figure 1).

Figure 1.

Figure 1.

2-Crossover trial flow design. Notes: T: test preparation = Boke®; R: reference preparation = Glucophage®-XR. Washout period = 7 d.

For the metformin assay, venous blood samples (approximately 4 mL) were drawn from all participants through an indwelling cannula into tubes containing the anticoagulant K2-ethylenediaminetetraacetic acid, before administration (0 h; within 10 min before administration) and 1, 1.5, 2.5, 3, 4, 5, 6, 7, 8, 9, 10, 12, 15, 24, 36 and 48 h after administration. The blood samples were centrifuged at 2500 × g at 4 °C for 10 min, and the obtained plasma was transferred to freshly labelled tubes, kept frozen at −20 ± 10 °C for 1 h and subsequently at −70 ± 10 °C for 3 d, and stored until further analysis. After a washout period of 7 d, the formulation was cross-administered.

Medical surveillance was performed continuously throughout the trial. The vital signs of the participants were monitored during the screening period, before admission and departure from the hospital during each period, and 4, 8, 24 and 48 h after administration. The following safety checks were conducted before the participants left the research centre on the third day (D3) in the first period, when they returned to the hospital the day before the second dose, and before they left the research centre again at D10 in the second period: laboratory tests (including blood biochemistry, blood routine, urine routine and serum pregnancy test for women only) and physical examination. In addition to the above examinations, the participants were subjected to substance abuse tests and alcohol breath tests and were required to monitor their ECG before leaving the hospital after trial completion at D10 in the second period (or prior to withdrawal). Adverse events were closely observed during the trial, and the participants were asked to report any discomfort. Drug combination and non-drug treatment were recorded in detail during the trial. All AEs occurring during the trial were followed up until the disappearance of the AE, stabilization, or loss of follow-up.

Bioanalytical methods

Quantitative analysis of metformin in the plasma was conducted on an LC-30AD liquid pump high-performance liquid chromatography (HPLC) system (AB Sciex, Foster City, USA), combined with an API 4000 Triple Quadrupole Mass Spectrometer (MS/MS) (Shimadzu, Kyoto, Japan). Metformin was extracted from the plasma using protein precipitation and concentration methods [14]. The plasma sample (100 μL) was added into a 96-well plate, followed by the addition of an internal standard solution (metformin-D6, 250 ng/mL) or 20 μL of methanol/aqueous solution (20:80 v/v). Methanol (500 μL) was added after vortex oscillation for 30 s (1000 × g), followed by vortex oscillation for 10 min (1000 × g) and centrifugation for 10 min (6000 × g). The resulting supernatant (5 μL) was injected into an HPLC-MS/MS system for analysis.

Method validation was performed according to the NMPA and Drug Administration Bioanalytical Method Validation Guidance. The linear range was defined as 1–1000 ng/mL, based on verification. The lower limit of quantification for metformin was 1 ng/mL, using a validated HPLC-MS/MS method. All the other results, such as selectivity, lower limit of quantitation, precision, accuracy, matrix effect, recovery and stability met the acceptance criteria.

Plasma metformin concentrations were analysed by Frontage Laboratories Inc. (Shanghai, China), according to the guidelines for bioequivalence published by the China Food and drug Administration (CFDA, renamed as NMPA in 2018).

Pharmacokinetic analysis

Pharmacokinetic analysis was conducted only for samples from participants who had taken the trial drugs in two periods. Pharmacokinetic parameters were analysed using Certara Phoenix WinNonlin version 7.0 (Pharsight Corporation, Princeton, NJ, USA).

The blood concentration–time curve (C–T curve) was obtained by mapping the plasma metformin concentration at each time point. The peak concentration (Cmax) was obtained from this graph. The area under the curve (AUC) from time 0 to the time of the last measurable concentration (AUC0→t) was calculated using the linear trapezoidal rule. The AUC from time 0 to infinity (AUC0→∝) was obtained using the formula AUC0→∝ = AUC0→t + Ct/λz, where Ct is the final measurable concentration and λz is the elimination rate constant, which is the slope of the terminal segment of the linear regression curve of the logarithmically transformed drug concentration values vs. time. Moreover, the time to peak concentration (Tmax) was obtained directly from the C–T curve. T1/2 is the elimination half-life, calculated as 0.693/λz. Log-transformed primary pharmacokinetic parameters were tested using analysis of variance (ANOVA). The results of the mixed effects model included sequence, period and preparation factors [11,13,15].

Pharmacokinetic bioequivalence analysis of MH-SR and Glucophage®-XR was conducted using the geometric mean ratio (GMR), 90% CI, and two-sided t-test. Pharmacokinetic bioequivalence was established between MH-SR and Glucophage®-XR if the 90% CIs of the main pharmacokinetic parameters were within the equivalent interval (80.00–125.00%).

Safety assessment

We statistically analysed data from all randomized participants who were administered the trial drug and who had safety records. We monitored AEs, serious AEs (SAEs), concomitant medication, non-drug therapies, abnormal clinical manifestations, changes in laboratory results (routine blood, urine, stool and blood biochemistry), and ECG to ensure the safety of the clinical trial. All participants with AEs, whether considered drug-related or not, were regularly monitored if feasible until recovery, stability, or irreversible damage.

All AEs were assessed using the Common Terminology Criteria for Adverse Events version 4.03. The degree of correlation between AEs and drug administration was classified into the following five levels, according to the judgement standard of causality between drugs and AEs: definitely unrelated, unlikely related, possibly related, probably related and definitely related. Events classified as possibly related, probably related and definitely related were listed as adverse drug reactions (ADRs).

Statistical analysis

According to previous clinical studies, the mean intra-individual coefficient of variation (CV%) for AUC of MH-SR tablets is 22.2% [16]. The GMR of the test and reference preparations (T/R) was set as 1.1, the power was 0.80 (1 – β = 0.80), and the bilateral significance level was .05 (α = 0.05). It was estimated that a minimum sample size of 38 was required to prove the bioequivalence of MH-SR. Considering the 20% risk of dropout, a sample size of 48 participants was considered in the trial [17].

The normality of the measured data was tested using the KS method. Data with normal distribution were represented as the mean ± standard deviation (x±s), and the difference between the two groups was tested using the t-test. Data with a non-normal distribution were represented as the quartile (25 and 75%), and the difference between the two groups was tested using the Wilcoxon rank-sum test. Count data were represented as numbers and percentages (n, %), and the difference between the two groups was tested using the chi-square test.

The main pharmacokinetic parameters were logarithmically transformed before statistical analysis since they are usually distributed log-normally [11,13]. Any difference between the two related parameters was deemed statistically significant at p ≤ .05. Statistical analyses were performed using SAS version 9.2.

Results

Participants

A total of 133 participants were selected for the fasting test, of which 85 (63.9%) failed and 48 (36.1%) were randomly allocated to the T-R or R-T subgroups. Among the included participants, 36 (75.00%, 36/48) were men (Figure 2). Han ethnicity accounted for 97.92% (47/48). The age of the participants was 27.9 ± 7.6 years (range: 18–46 years); body weight, 65.2 ± 8.0 kg (range: 52.9–83.7 kg); height, 168.7 ± 7.0 cm (range: 153.8–186.1 cm); and body mass index, 22.9 ± 2.3 kg/m2 (range: 19.1–27.5 kg/m2). There were no significant differences in the demographic characteristics between the T-R and R-T subgroups (Table 2).

Figure 2.

Figure 2.

Flow diagram of screening participants for the clinical trial. Notes: T: test preparation = Boke®; R: Reference preparation = Glucophage®-XR; AEs: adverse events. *The reasons of ineligibility: single A (60), single B (11), single D (2), single E (7), combined A + C (1), combined A + D (1) and combined D + E (1). (A) Abnormality in physical examination, vital sign examination, laboratory examination and electrocardiogram; (B) Previous digestive disease or surgery that may interfere with drug absorption; (C) Hepatitis B surface antigen test positive or active hepatitis B; (D) Use of any other drugs in the two weeks prior to the start of the study; (E): The investigator determined that the subject could not complete the study or otherwise believed that the subject’s participation in the study might cause harm. #The two substitute volunteers were used for replacement volunteers who were unable to participate in the trial for various reasons before randomization.

Table 2.

The demographic and baseline characteristics of subjects in the clinical trials.

Characteristics T-R R-T Statistic p Value
Number (n) 24 24
Age (years) 28.3±7.9 27.5±7.3 −0.36^ .721
Gender, male (n, %) 17 (70.8) 19 (79.2) 0.44# .505
The Han Ethnicity (n, %) 24 (100.0) 23 (95.8) .999*
Height (cm) 169.5±7.2 168.0±6.8 −0.75^ .460
Body weight (kg) 66.0±8.8 64.3±7.3 −0.73^ .467
Body mass index (kg/m2) 23.0±2.5 22.8±2.2 −0.24^ .812

Notes: ^t value; #Chi square value; *Fisher’s exact test; T: test preparation = generic metformin hydrochloride sustained-release tablets; R: reference preparation = Glucophage-XR.

Forty-two participants completed the trial, while the remaining six participants withdrew from the trial. One participant experienced venipuncture syncope prior to the first period of administration, two decided by themselves to withdraw from the trial prior to the second dose administration, and the other three reported AEs following the first dose (Supplementary Table S1). The safety analysis set included 47 participants; 42 participants were a part of the pharmacokinetic analysis set (Figure 2).

Bioequivalence assessment

Table 3 shows the main pharmacokinetic parameters of MH-SR (500 mg) and Glucophage®-XR (500 mg) in the study participants. No significant difference was observed in the main pharmacokinetic parameters between MH-SR and Glucophage®-XR (p = .81, .76 and .61 for AUC0→t, AUC0→∝ and Cmax, respectively).

Table 3.

Comparison of arithmetic mean of generic metformin hydrochloride sustained-release tablets (MH-SR, 0.5g) and Glucophage-XR (0.5g) in healthy Chinese volunteers under single-dose administration and fasting conditions (n=42).

Pharmacokinetic parameter T (MH-SR) R (Glucophage-XR) t Value p Value
AUC0→t (h·mg·L−1) 5080.60±1132.68 4999.6±1254.62 −0.24 .81
AUC0→∝ (hr·mg·L−1) 5203.80±1255.33 5099.00±1231.00 −0.31 .76
Cmax (mg·L−1) 724.14±216.43 697.54±199.03 −0.52 .61
*Tmax (h) 4.00 (1.50, 5.00) 4.00 (1.50, 5.00) 0.67 .50
t1/2 (h) 10.38±7.10 10.23±6.79 −0.06 .96
λz (1/h) 0.09±0.03 0.08±0.03 −0.15 .88

Notes: *a non-normal distribution data was denoted by the quartile and tested by chi-square test Wilcoxon rank sum test.

T: test preparation; R: reference preparation.

Table 4 shows the bioequivalence analysis results for MH-SR and Glucophage®-XR in the study participants under single-dose administration and fasting conditions. The GMR ratio (T/R) of AUC0→t, AUC0→∝ and Cmax of MH-SR and Glucophage®-XR were 102.68, 102.53 and 103.81%, respectively; the 90% CIs were 97.36–108.30, 97.26–108.09 and 96.76–111.37%, respectively. Since the 90% CIs of the main pharmacokinetic parameters were within the equivalent interval (80.00–125.00%), we conclude that the test and reference formulations were bioequivalent under single-dose administration and fasting conditions.

Table 4.

Bioequivalence analysis of generic metformin hydrochloride sustained-release tablets (T, 0.5g) and Glucophage-XR (R, 0.5g) in healthy Chinese volunteers (n=42) under single-dose administration and fasting conditions.

Pharmacokinetic parameter Geometric mean value and ratio
90% CI (%) COV (%) Power (%)
T R T/R (%)
AUC0→t (hr·ng/mL) 4960.65 4831.00 102.68 97.36–108.30 14.54 100.0
AUC0→∞ (hr·ng/mL) 5070.54 4945.31 102.53 97.26–108.09 14.42 100.0
Cmax (ng/mL) 694.42 668.94 103.81 96.76–111.37 19.29 99.7

Note: T: test preparation; R: reference preparation; COV: coefficient of variation here means intra-individual variation.

Power=1 – β, type II error.

The C–T curves of Boke® and Glucophage®-XR were in good agreement (Figures 3 and 4).

Figure 3.

Figure 3.

Mean (n=42) plasma concentration-time curves of Boke® and Glucophage®-XR in healthy Chinese volunteers under single-dose administration and fasting conditions (linear plot).

Figure 4.

Figure 4.

Mean (n = 42) plasma concentration-time curves of Boke® and Glucophage-XR in healthy Chinese volunteers under single-dose administration and fasting conditions (semilogarithmic plot).

Additionally, no significant differences were observed between the main parameters of the test and reference product as identified by ANOVA (p = .17, .75 and .38 for sequence, periods and formulations, respectively) (Table 5). The results demonstrated that the mixed effects model included sequence, period and preparation factors that did not interfere with the conclusions of the study.

Table 5.

Results (p values) of ANOVA test of bioequivalence between generic metformin hydrochloride sustained-release tablets (T, 0.5g) and Glucophage-XR (R, 0.5g) in healthy Chinese volunteers (n=42) under single-dose administration and fasting conditions.

Influence factor lnAUC0→t lnAUC0→∞ lnCmax
Sequence 0.46 0.56 0.17
Periods 0.29 0.54 0.75
Formulations 0.41 0.43 0.38

Post-hoc analysis revealed that the AUC0→t, AUC0→∝ and Cmax of Boke® and Glucophage®-XR in females were higher than the corresponding values in males (6037.05 ± 1264.46 vs. 4819.72 ± 916.47 ng/mL, 6276.50 ± 1628.88  vs. 4911.17 ± 913.46 ng/mL, 893.30 ± 273.65  vs. 678.02 ± 166.92 ng/mL, respectively, for Boke® and 5621.24 ± 866.29 vs. 4830.32 ± 1271.17 ng/mL, 5803.62 ± 838.00  vs. 4906.80 ± 1232.48 ng/mL, 744.88 ± 189.84 vs. 684.62 ± 196.48 ng/mL, respectively, for Glucophage®-XR). Figures 5 and 6 show that the C–T curves of Boke® and Glucophage®-XR are categorized by the gender of the participants.

Figure 5.

Figure 5.

Mean plasma concentration-time curves of Boke® categorize by gender of healthy Chinese volunteers under single-dose administration and fasting conditions (linear plot).

Figure 6.

Figure 6.

Mean plasma concentration-time curves of Glucophage®-XR categorize by gender of healthy Chinese volunteers under single-dose administration and fasting conditions (linear plot).

Safety and tolerability

In total, 41 AEs occurred in 19 participants. Of the 46 participants who were administered the test drug, 10 participants (21.74%, 10/46) showed 23 ADRs. Of the 43 participants who were administered the reference drug, Glucophage®-XR, 12 participants (27.91%, 12/43) showed 15 ADRs. No significant differences in ADRs were identified between the test and reference products (21.74 vs. 27.91%, p = .500) (Table 6).

Table 6.

Adverse events of generic metformin hydrochloride sustained-release tablets (0.5g, T) and Glucophage-XR (0.5g, R).

Adverse events T (n=46)
R (n=43)
χ 2 p Value
AEs (N) Cases (n, %) AEs (N) Cases (n, %)
Metabolic or nutritional diseases 3 3 (6.5) 5 5 (11.6) .475*
 Hypertriglyceridemia 1 1 (2.2) 3 3 (7.0) .350*
 Hyperuricemia 2 2 (4.3) 2 2 (4.7) .999*
Infectious diseases 2 2 (4.3) 0 0 (0.0) .495*
 Upper respiratory tract infection 2 2 (4.3) 0 0 (0.0) .495*
All kinds of abnormal inspection 12 5 (10.9) 6 5 (11.6) .999*
 γ-Glutamyl-transferase () 0 0 (0.0) 1 1 (2.3) .483*
 Alanine aminotransferase () 0 0 (0.0) 1 1 (2.3) .483*
 Conjugated bilirubin () 4 4 (8.7) 2 2 (4.7) .678*
 Urine ketone bodies (+) 1 1 (2.2) 0 0 (0.0) .999*
 Blood in the urine 1 1 (2.2) 0 0 (0.0) .999*
 Blood bilirubin () 3 3 (6.5) 0 0 (0.0) .242*
 Blood unbound bilirubin () 3 3 (6.5) 0 0 (0.0) .242*
 Serum creatine phosphokinase () 0 0 (0.0) 1 1 (2.3) .483*
 Neutrophil count () 0 0 (0.0) 1 1 (2.3) .483*
Gastrointestinal diseases 6 4 (8.7) 4 4 (9.3) .999*
 Abdominal pain 3 3 (6.5) 0 0 (0.0) .242*
 Diarrhoea 3 3 (6.5) 3 3 (7.0) .999*
 Abdominal distension 0 0 (0.0) 1 1 (2.3) .483*
Total 23 10 (21.7) 15 12 (27.9) 0.454 .500

Note: *Fisher exact test; ↑increasing; +positive.

T: test preparation; R: reference preparation.

Among the 23 ADRs during the administration of MH-SR, 15 ADRs (65.22%, 15/23) and 8 ADRs (34.78%, 8/23) were of common terminology criteria for adverse events (CTCAE) Grade 1 and Grade 2, respectively. Among the 15 ADRs during the administration of Glucophage®-XR, 13 ADRs (86.67%, 13/15) and 2 ADRs (13.33%, 2/15) were of CTCAE Grade 1 and Grade 3, respectively. No significant differences in ADR severity were identified between MH-SR and Glucophage®-XR (p = .26, Fisher’s Exact Test). The outcome of all the above-mentioned ADRs was “recovered/resolved”. The details of all AEs that occurred during the trial are listed in Supplementary Table S2.

Discussion

The main goal of this study is to support an increase in the supply of MH-SR in China by proving the efficacy and safety of a generic alternative. This trial was performed according to the last national regulation, a strict standard [18]. The innovator drug, Glucophage®-XR (500 mg), was used as a reference. HPLC-MS/MS, which is currently widely used for bioequivalence evaluation, was used in this clinical trial [13].

Zhou et al. [19] studied the bioequivalence of MH-SR tablets and Glucophage®-XR (500 mg) as a reference preparation under fed states. HPLC-MS/MS was used for testing, and 19 blood sampling points within 0–36 h were selected. The following data were obtained for the test and reference preparations in Zhou et al. study and our study under fed states, respectively: AUC0→36 = 6.56 ± 0.81 (range 5.31–7.80) h·mg·L−1 and 6.75 ± 1.22 (range 4.89–8.60) h·mg·L−1; AUC0→∝ = 6.63 ± 0.82 (range 5.34–7.86) h·mg·L−1 and 6.83 ± 1.22 (range 4.93–8.70) h·mg·L−1; AUC0→48 = 7.33 ± 1.65 and 7.00 ± 1.89h·mg·L−1; and AUC0→∝ = 7.39 ± 1.67 and 7.06 ± 1.91h·mg·L−1. No significant differences were observed between the main pharmacokinetic parameters. We previously reported the bioequivalence of the generic MH-SR produced by Guangdong Sinocorp Pharmaceutical Co. Ltd., Guangdong, China and the innovator product Glucophage®-XR in healthy Chinese participants, with similar results [11]. The values of the main pharmacokinetic parameters in the above studies were different from that in this study because of differences between postprandial and fasting conditions. A thorough literature search revealed more reports on the bioequivalence of MH-SR under postprandial conditions than that under fasting conditions.

According to the requirements of NMPA, bioequivalence tests of MH-SR tablets were conducted successively under fasting and postprandial conditions. Here, the results of bioequivalence trials under fasting conditions are reported. Compared with the results of the postprandial trial, AUC0→t and AUC0→∝ are lower (4960.65 vs. 7148.53 h·ng/mL and 5070.54 vs. 7205.59h·ng/mL), while Cmax is slightly higher (694.42 vs. 671.57 ng/mL) under fasting conditions.

The instruction manual of Glucophage® and Glucophage®-XR specifies that metformin pharmacokinetic parameters did not differ significantly between normal subjects and patients with type 2 diabetes mellitus when analysed according to gender (males = 19 and females = 16) [20]. However, the results of this study indicate that gender could affect the pharmacokinetics of metformin. Animal experiments have shown that gender-related differences were observed in the pharmacokinetics of metformin when administered at relatively high doses; the plasma concentration of metformin in female rats was significantly increased compared to that in male rats at 2 h after oral administration [21].

Metformin has been used in clinical practice for more than 60 years, and sufficient data are available to prove its safety [22]. No SAEs or unexpected AEs occurred in healthy Chinese participants who were administered MH-SR or Glucophage®-XR in this clinical trial. The number of ADRs in this study was limited. All types of abnormal inspection occurred most frequently during this clinical trial, followed by gastrointestinal, metabolic or nutritional diseases. In the instruction manual of Glucophage® and Glucophage®-XR 2020, the most common adverse reactions reported in the GLUCOPHAGE XR (n = 781) were diarrhoea (10%) and nausea (7%). This result is different from that reported in this study (n = 48); this inconsistency may be related to the small sample size of this study.

According to the BE guidelines for metformin hydrochloride tablets by the FDA, the drug products should be administered with 240 mL of a 20% glucose water solution, followed by administration of 60 mL of the glucose solution every 15 min for up to 4 h [15]. However, metformin does not generally cause hypoglycaemia in healthy participants since it increases endogenous glucose production in non-diabetic individuals [23]. No event of hypoglycaemia occurred even though no sugar was given in this fasting condition. Both MH-SR and Glucophage®-XR were safe and well tolerated.

However, this study had some limitations. First, the study was designed as a single-centred clinical trial with a limited sample size. The small sample size did not reveal all ADRs of the MH-SR, such as vitamin B12 deficiency and lactic acidosis (Supplementary, Instruction manual of Boke®). Fortunately, there were no significant differences in the ADRs between the two MH-SR formulations. The absence of all ADRs that occurred in the study affected the judgement of the results. Moreover, China is a multi-ethnic country, and most of the participants in this study were Han. The impact of ethnicity on the differences between the two preparations was not considered in this study. However, this limitation could be offset by the results of a previous study, which demonstrated that the ADRs of the MH-SR formulation do not differ significantly among different ethnic groups [15].

Conclusions

Generic MH-SR tablets (Beijing Wanhui Double-crane Pharmaceutical Co. Ltd., China) and innovator MH-SR tablets (Glucophage®-XR, Bristol-Myers Squibb Company, New York, NY, USA) were bioequivalent and safe in healthy Chinese volunteers under single-dose administration and fasting conditions.

Supplementary Material

Supplemental Material

Acknowledgements

The authors thank the volunteers participating in the clinical trial. We are grateful to Frontage Pharmaceutical Technology Co. Ltd. and Jiaxing Tigermed Data Management Co., Ltd.; the former was the contract research organization and responsible for detection of drug concentration in plasma; the latter was responsible for data management and the statistical analysis. The funders of the study had no role in data collection, data analysis, data interpretation or writing of the article. All authors had full access to all the data in the study and had final responsibility for the decision to submit for publication.

Funding Statement

This clinical trial was sponsored by China Resources Doublecrane Pharmaceutical Co., Ltd., Beijing 100102, China. The article publishing charge (APC) was partially supported by the Open Research Funding of Central Laboratory, Beijing Shijitan Hospital Affiliated to Capital Medical University [Grant No. 2020-KF28] and Clinical research platform construction Project of Beijing Science and Technology Commission (Grant No. 2018LQYJ).

Ethical approval

Written informed consent was obtained from all the participants prior to the study. The study protocol and related documents were reviewed and approved by the Institutional Review Board of Beijing Shijitan Hospital (approval no. 2017Y94).

Author contributions

Sun ML, Liu C, Bai HH, Wei YL, Zhang W, Liu HJ, Li YJ, Liu L, Wang Y, Tong YX, Gao Q, Liu QY and Wang X participated in the conception and design of the work and conducted analysis and interpretation of the data. Sun ML drafted the article. Liu C, Bai HH, Wei YL, Zhang W, Liu HJ, Li YJ, Liu L, Wang Y, Tong YX, Gao Q, Liu QY and Wang X revised it critically for intellectual content. Sun ML, Liu C, Bai HH, Wei YL, Zhang W, Liu HJ, Li YJ, Liu L, Wang Y, Tong YX, Gao Q, Liu QY and Wang X approved the final version to be published and agree to be accountable for all aspects of the work.

Disclosure statement

Qian Gao and Qian-Ying Liu are employees of China Resources Double-crane Pharmaceutical Co. Ltd. No potential conflict of interest was reported by the author(s). None of the authors had any financial or other substantive conflicts of interest that may be construed to influence the results or interpretation of the manuscript.

Data availability statement

Data sharing is not applicable to this article as no new data were created or analysed in this study.

References

  • 1.IDF . IDF atlas 10th ed. Brussels: International Diabetes Federation; 2022. p. c1950 [cited 2022 Feb 28]. Available from: https://diabetesatlas.org/atlas/tenth-edition/.
  • 2.Wang L, Peng W, Zhao Z, et al. Prevalence and treatment of diabetes in China, 2013–2018. JAMA. 2021;326(24):2498–2506. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 3.Draznin B, Aroda VR, Bakris G, et al. 2. Classification and diagnosis of diabetes: standards of medical care in diabetes-2022. Diabetes Care. 2022;45(1):S17–S38. [DOI] [PubMed] [Google Scholar]
  • 4.Chinese Elderly Type 2 Diabetes Prevention and Treatment of Clinical Guidelines Writing Group; Geriatric Endocrinology and Metabolism Branch of Chinese Geriatric Society; Geriatric Endocrinology and Metabolism Branch of Chinese Geriatric Health Care Society; Geriatric Professional Committee of Beijing Medical Award Foundation; National Clinical Medical Research Center for Geriatric Diseases (PLA General Hospital). Clinical guidelines for prevention and treatment of type 2 diabetes mellitus in the elderly in China (2022 edition). Zhonghua Nei Ke Za Zhi. 2022;61(1):12–50. [DOI] [PubMed] [Google Scholar]
  • 5.Chang CT, Ang JY, Wong JM, et al. Bioequivalence and pharmacokinetic comparison of two fixed dose combination of metformin/glibenclamide formulations in healthy subjects under fed condition. Med J Malaysia. 2020;75(3):286–291. [PubMed] [Google Scholar]
  • 6.Scheen AJ. Clinical pharmacokinetics of metformin. Clin Pharmacokinet. 1996;30(5):359–371. [DOI] [PubMed] [Google Scholar]
  • 7.McCreight LJ, Bailey CJ, Pearson ER.. Metformin and the gastrointestinal tract. Diabetologia. 2016;59(3):426–435. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 8.Mead E, Atkinson G, Richter B, et al. Drug interventions for the treatment of obesity in children and adolescents. Cochrane Database Syst Rev. 2016;11(11):CD012436. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 9.Wang GS, Hoyte C.. Review of biguanide (metformin) toxicity. J Intensive Care Med. 2019;34(11–12):863–876. [DOI] [PubMed] [Google Scholar]
  • 10.Gout-Zwart JJ, de Jong LA, Saptenno L, et al. Budget impact analysis of metformin sustained release for the treatment of type 2 diabetes in The Netherlands. Pharmacoecon Open. 2020;4(2):321–330. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 11.Sun ML, Liu HJ, Luo XD, et al. Bioequivalence and safety assessment of two formulations of metformin hydrochloride sustained-release tablets (Yuantang and Glucophage XR) under fed conditions in healthy Chinese adult subjects: an open-label, two-way crossover, sequence randomized phase I clinical trial. Drugs R D. 2022;22(1):51–60. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 12.ICH . ICH harmonisation for better health. Press release ICH assembly meeting in Montreal, Canada. Geneva, Switzerland: The International Council for Harmonisation of Technical Requirements for Pharmaceuticals for Human Use; 2017. p. c1990 – 2022 [cited 2022 Feb 24]. Available from: https://www.ich.org/news/press-release-ich-assembly-meetingmontreal-canada-mayjune-2017.
  • 13.Sun ML, Qi L, Luo XD, et al. Pharmacokinetic bioequivalence and safety assessment of two metformin hydrochloride tablet formulations using a phase I, randomized, open, two-period, two cross-over, single-dose, fed study in healthy Chinese adult subjects. Int J Clin Pharmacol Ther. 2021;59(9):630–638. [DOI] [PubMed] [Google Scholar]
  • 14.Abbas Moussa B, Mahrouse MA, Fawzy MG.. A validated LC-MS/MS method for simultaneous determination of linagliptin and metformin in spiked human plasma coupled with solid phase extraction: application to a pharmacokinetic study in healthy volunteers. J Pharm Biomed Anal. 2019;163:153–161. [DOI] [PubMed] [Google Scholar]
  • 15.Huang XM, Wang GZ, He BB, et al. Bioequivalence and pharmacokinetic evaluation of two metformin hydrochloride tablets under fasting and fed conditions in healthy Chinese volunteers. Clin Pharmacol Drug Dev. 2020;9(8):910–917. [DOI] [PubMed] [Google Scholar]
  • 16.Batolar LS, Iqbal M, Monif T, et al. Bioequivalence and pharmacokinetic comparison of 3 metformin extended/sustained release tablets in healthy Indian male volunteers. Arzneimittelforschung. 2012;62(1):22–26. [DOI] [PubMed] [Google Scholar]
  • 17.Julious SA. Sample sizes for clinical trials with normal data. Stat Med. 2004;23(12):1921–1986. [DOI] [PubMed] [Google Scholar]
  • 18. CFDA. Opinions of the general office of the state council of the People’s Republic of China on consistency evaluation of quality and efficacy of generic drugs (No. 8 of). Beijing, China: The China Food and Drug Administration (renamed “National Medical Products Administration” (NMPA) in 2018); 2016. p. c2003–2018 [cited 2022 Feb 28]. Available from: https://www.nmpa.gov.cn/xxgk/fgwj/qita/20160305170501219.html.
  • 19.Zhou Z, Wang C, Li M, et al. In vitro dissolution and in vivo bioequivalence evaluation of two metformin extended-release tablets. Clin Pharmacol Drug Dev. 2021;10(4):414–419. [DOI] [PubMed] [Google Scholar]
  • 20. Instruction manual of Glucophage and Glucophage-XR . Last reviewed on RxList: 5/20/2020. [Internet]. New York (NY): Bristol-Myers Squibb Company; 2020. p. c1995–2022 [accessed May 20, 2020]. [cited 2022.04.07]. Available from https://www.rxlist.com/glucophage-drug.htm#indications
  • 21.Ma YR, Qin HY, Jin YW, et al. Gender-related differences in the expression of organic cation transporter 2 and its role in urinary excretion of metformin in rats. Eur J Drug Metab Pharmacokinet. 2016;41(5):559–565. [DOI] [PubMed] [Google Scholar]
  • 22.Griffin SJ, Leaver JK, Irving GJ.. Impact of metformin on cardiovascular disease: a Meta-analysis of randomised trials among people with type 2 diabetes. Diabetologia. 2017;60(9):1620–1629. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 23.Gormsen LC, Søndergaard E, Christensen NL, et al. Metformin increases endogenous glucose production in non-diabetic individuals and individuals with recent-onset type 2 diabetes. Diabetologia. 2019;62(7):1251–1256. [DOI] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

Supplemental Material

Data Availability Statement

Data sharing is not applicable to this article as no new data were created or analysed in this study.


Articles from Annals of Medicine are provided here courtesy of Taylor & Francis

RESOURCES