Skip to main content
Thoracic Cancer logoLink to Thoracic Cancer
. 2022 Aug 29;13(20):2854–2860. doi: 10.1111/1759-7714.14629

Radial‐EBUS and virtual bronchoscopy planner for peripheral lung cancer diagnosis: How it became the first‐line endoscopic procedure

Samy Lachkar 1,, Loic Perrot 1, Diane Gervereau 1, Marielle De Marchi 1, Helene Morisse Pradier 1, Edouard Dantoing 1, Nicolas Piton 2,3, Luc Thiberville 4, Florian Guisier 4, Mathieu Salaün 4
PMCID: PMC9575082  PMID: 36054681

Abstract

Background

Various advanced bronchoscopy methods have been developed to reach peripheral lung lesions (PLL). In a large cohort, we aimed to assess a standardized procedure of first‐line radial‐endobronchial ultrasound (r‐EBUS) and virtual bronchoscopy planner for the diagnosis of peripheral lung cancer.

Methods

This retrospective, single center study included patients who had r‐EBUS‐guided bronchoscopy for the diagnosis of a PLL between 2008 and 2019. Cases without a final diagnosis of cancer or follow‐up were excluded.

Results

Between 2008 and 2019, 2735 patients had a r‐EBUS procedure, among whom 1627 had a final diagnosis of cancer and were included in the present study. Over the 12‐year study period, r‐EBUS became the first‐line endoscopic procedure to assess PLL (25% as first‐line bronchoscopy in 2008 vs. 92% in 2019). The frequency of the bronchus sign decreased from 2009 to 2019 (100% to 80%; p = 0.001), whereas US visualization of the lesion remained stable (88%). The median number of biopsies increased from two (2008 to 2014) to four (2015 to 2019) (p < 0.0001), with the same diagnostic efficiency (74% total and 80% when a bronchus sign was present). Of the 651 adenocarcinomas, molecular analysis was possible in 86%. PD‐L1 expression analysis was possible in 81% of cases. During the study period, the lifetime of the radial probe increased from 57 procedures to 77 procedures/probe.

Conclusion

Because r‐EBUS and VB planner is easy to perform under local anesthesia, inexpensive and efficient it can be used as a first‐line procedure to assess peripheral lung cancer.

Keywords: bronchoscopy, lung cancer, peripheral pulmonary nodule, radial endobronchial ultrasound, virtual bronchoscopy planner


Between 2008 and 2019, 1627 cases with final diagnosis of cancer and were included. Over this period, R‐EBUS and VB planner became the first‐line endoscopic procedure to assess PLL, (25% as first‐line bronchoscopy in 2008 vs. 92% in 2019). The frequency of the bronchus sign decreased from 2009 to 2019 whereas the same diagnostic efficiency remains stable (74% total and 80% when a bronchus sign was present). Of the 651 adenocarcinomas, molecular analysis and PDL1 were possible in more than 80% of cases.

graphic file with name TCA-13-2854-g002.jpg

INTRODUCTION

Lung cancer is the most commonly diagnosed cancer, and the leading cause of cancer‐related deaths worldwide, with 18% of cancer deaths in 2018. 1 When detected in the early stages, curative surgical options can be considered, significantly improving survival. Aimed at detecting earlier stages, the National Lung Screening Trial showed a survival advantage in patients screened on a yearly basis with low dose chest computed tomography (CT), 2 despite an increase of incidentally detected solitary pulmonary lesions of unknown origin.

In order to obtain a definitive diagnosis of peripheral pulmonary nodules, tissue sampling is often required. CT‐guided percutaneous needle biopsy (CT‐PNB) can be performed. However, it is associated with a high rate of pneumothorax, cited between 15% and 43%, as well as a risk of pulmonary hemorrhage, reported between 1.0% and 27%. 3 , 4

Standard flexible bronchoscopy has a variable and often poor success rate in sampling peripheral pulmonary lesions during endobronchial examination. 5 , 6

Various advanced bronchoscopy methods have been developed to reach peripheral nodules such as electromagnetic navigation, radial endobronchial ultrasound (r‐EBUS), virtual bronchoscopy, and more recently robotic bronchoscopy. 7 , 8 Currently, these procedures are often proposed as second attempts after standard bronchoscopy failure, leading to increased cost and time until the diagnosis of a peripheral nodule.

In a large cohort, we aimed to assess a standardized procedure of r‐EBUS and virtual bronchoscopy planner as the first‐line diagnostic procedure for peripheral lung cancer.

METHODS

Patients

This retrospective, single‐center study included consecutive patients who had r‐EBUS‐guided bronchoscopy for the diagnosis of a peripheral pulmonary lesion at Rouen University Hospital, France, between April 2008 and December 2019. Patients without a final diagnosis of cancer or who had a previous r‐EBUS procedure were excluded.

The study protocol was approved by the Institutional Review Board for noninterventional research of our center: Rouen University Hospital (protocol agreement #E2020‐80).

R‐EBUS procedure

Before each procedure, the location of the lesion was analyzed using the planner of the virtual bronchoscopy software (Figure 1a) to identify the optimal bronchial path to the lesion from 2008 to 2011: Superdimension planner (superDimension/Bronchus system, superDimension Ltd.) and since 2011, LungPoint planner (Broncus Medical Inc.), from a millimeter slice chest CT‐scan. Bronchoscopy was then carried out using local or general anesthesia with either an MP160F video bronchoscope or a BF‐MP60F bronchofiberscope (Olympus), with a 4 mm outer diameter and a 2 mm working channel.

FIGURE 1.

FIGURE 1

(a) Virtual bronchoscopy planner (LungPoint, Broncus Medical Inc.). (b) A 4 mm scope (MP160F video bronchoscope or a BF‐MP60F bronchofiberscope (Olympus). (c) Radial‐endobronchial ultrasound (EBUS) image with ultrasonic image of a nodule

The ultrasonographic probe was the 1.4 mm UM‐S20‐17S probe (Olympus) (Figure 1b), introduced into the dedicated 1.9 mm‐diameter guide catheter (K201, Olympus).

The procedure was performed without navigation or fluoroscopy. After having memorized the endobronchial route from the planning, the operator reached the most distal subsegmental bronchus. The r‐EBUS probe, covered with the guide sheath, was then inserted into the working channel and gently pushed until a lesion‐specific ultrasonographic image could be obtained, as described elsewhere. 9 , 10 R‐EBUS views of peripheral lesions were characterized as “centered” when the radial probe appeared within and completely surrounded by the lesion and “tangential” when the probe was adjacent to the lesion, without tissue completely surrounding the probe.

Once the nodule US signal was obtained (Figure 1c), the probe was removed and the guide sheath was left in place in the lesion. The sampling, including cytological brush and forceps biopsies, was then performed.

Rapid on‐site evaluation (ROSE) was not used.

Systematic chest radiographs were obtained after each procedure to ensure the absence of pneumothorax until 2017, then only in case of chest pain or respiratory symptoms following the procedure.

Specimens were considered diagnostic when a cytological, histological, or microbiological diagnosis was confirmed and consistent with the clinical presentation. Patients in whom the procedures were not diagnostic were referred for other sampling methods or surgery or were followed by surveillance chest CT‐scan, when appropriate. Data on the final diagnosis were collected from our center's electronic medical records and/or by interviewing the patient's pulmonologist when clinical follow‐up was performed elsewhere.

Statistical analysis

Descriptive statistics were performed using Prism (GraphPad) and R Statistical Software (version 4.0.5; R Foundation for Statistical Computing). Comparisons of qualitative and quantitative variables were made using Fisher's exact test or Mann‐Whitney test and chi‐squared, respectively. For multivariate analysis, parameters associated with a p‐value < 0.10 in the univariate analysis were integrated in a polynomial logistic regression model. Patients with missing data for tumor size were excluded from this analysis. All tests were two‐sided, with a p‐value = 0.05 indicating statistical significance. Missing data are indicated.

RESULTS

Patient characteristics

Between April 2008 and December 2019, 2735 patients had a r‐EBUS procedure (Figure 2). Among them, 695 patients were not included: 210 because the procedure was not the first r‐EBUS bronchoscopy and 485 because of the absence of a final diagnosis or follow‐up. A further 413 patients were secondarily excluded because the final diagnosis was not a cancer lesion.

FIGURE 2.

FIGURE 2

Flowchart

Finally, 1627 patients with a definitive diagnosis of lung cancer were included in the study, of which 67% were male, and the mean age was 70 years (min‐max = 19–91).

Characteristics of the lesions

The median diameter of the lesion was 29 mm in the long axis (IQR = 20–43 mm) and 20 mm in the short axis (IQR = 14–30 mm) (Table 1). The median distance between the nodule and the pleura was 12 mm (IQR = 0–29 mm). A bronchus sign was found on CT‐scan in 86% of cases (1399/1627).

TABLE 1.

Characteristics of the lesions

Lesions (n = 1627)
Median diameter (± IQR)
Long axis (mm) 29 (6–148)
Short axis (mm) 20 (4–99)
Median (± IQR) nodule‐to‐pleura distance (mm) 12(0–91)
Bronchus sign (yes/no) 1399 (85%) /228(15%)
Nodule location (%)
Right upper lobe 529(33%)
Right middle lobe 120(8%)
Right lower lobe 267 (16%)
Left upper lobe 461(28%)
Left lower lobe 250 (15%)
Local/general anesthesia (n) 1259 (77%)/368 (33%)
US image by r‐EBUS 1429(87%)
Concentric signal 1272 (89%)
tangential signal 157 (11%)

Abbreviation: US, ultrasound.

Histological results of r‐EBUS procedures

R‐EBUS + virtual bronchoscopy planner (VB) was the first bronchoscopy examination performed for 1114 patients (68%), whereas 513 (32%) had standard bronchoscopy with negative results before r‐EBUS. Procedures were performed under local anesthesia in 1259 cases (77%). No severe complication was reported. One case of pneumothorax was reported, with no need for chest tube placement (0.06%). A total of 88% of the lesions (1429/1627) could be visualized by r‐EBUS, of which 89% (1272/1429) with a centered signal and 11% (157/1429) with a tangential signal.

A lung cancer diagnosis was obtained on the r‐EBUS samples in 1200 patients (74%), including 1110 (93%) primary lung cancers (adenocarcinomas: 710 [64%], squamous carcinoma: 272, other: 131) and 90 secondary malignancies. In 223 cases (18% of the 1200 cancer cases), a lung cancer diagnosis was obtained on the cytological brush sample only (biopsy sample not contributive).

Biomarker analysis on diagnostic samples

Of the 651 adenocarcinomas with a diagnosis made after 2012, molecular analysis including ALK and ROS1 immunohistochemistry and EGFR, KRAS, BRAF, HER2 and MET mutation testing was possible in 560 cases (86%; 195 negative and 365 positive) (Figure 3).

FIGURE 3.

FIGURE 3

Results of the molecular analysis in the 651 adenocarcinomas

Since May 2017, we systematically performed immunohistochemistry analysis for the assessment of programmed death‐ligand one (PD‐L1) expression in non‐small cell lung cancers (NSCLC). Of the 391 r‐EBUS positive NSCLC, expression analysis of PD‐L1 was possible in 315 cases (81%) (127 PDL1 positive, 188 negative).

Factors influencing the diagnostic efficiency

R‐EBUS positivity for a malignant nodule was 74%, increasing to 80% (1113/1399) when a bronchus sign was found on CT‐scan and 82% (1154/1429) when an ultrasound image of the lesion was obtained. R‐EBUS positivity was 83% (1058/1272) when the r‐EBUS image was centered and 61% (96/157) when the image was tangential. The positivity of the procedure decreased to 5% (11/198) when no characteristic r‐EBUS image was obtained.

The positivity was 59% for lesions of <20 mm (203/343) and 75% for lesions of >20 mm (n = 674/ 897). In 385 cases, data were missing on the size.

In univariate analysis, bronchus sign, nodule diameter and US visualization were associated with a higher positivity of the procedure (Table 2). When r‐EBUS was the first‐line examination, the positivity of the procedure was lower (65% vs. 72%, p = 0.026 in univariate analysis). However, in multivariate analysis only bronchus sign, nodule diameter and US visualization were predictive factors of diagnostic efficiency. The performance of r‐EBUS as a first‐line examination was not associated with a lower positivity of the procedure (OR 0.862, 95% CI: 0.639;1.1, p = 033).

TABLE 2.

Influencing factors of positivity of the procedure

R‐EBUS negative (n = 365) R‐EBUS positive (n = 877) p‐value OR CI95 p‐value
First‐line 261 (72%) 570 (65%) 0.026 0.862 [0.639; 1.16] 0.33
BS 248 (68%) 797 (91%) <0.001 2.09 [1.43; 3.03] <0.001
Diameter 27.5 (±15.8) 35.8 (±19.5) <0.001 1.19 [1.09; 1.30] <0.001
US signal 236 (65%) 841 (96%) <0.001 8.56 [5.69; 13.2] <0.001

Abbreviations: BS, bronchus sign; US, ultrasound.

Changes in r‐EBUS strategy and performances over time

R‐EBUS procedures and results between 2008 and 2019 are summarized in Figure 4. The number of r‐EBUS procedures performed per year increased progressively to 220 and became the first‐line examination in 2012 (25% in 2008 vs. 92% in 2019). The mean size of sampled lesions remained stable during this period (29 ± 2 mm). The frequency of bronchus sign decreased from 2009 to 2019 (100%–80%; p = 0.001, Fisher's exact test), whereas US visualization of the lesion remained stable. The median number of biopsies increased from two (2008 to 2014) to four (2015 to 2019) (p < 0.0001; Mann–Whitney test), but the positivity of the procedure (74%) remained the same between the two periods. The lifetime of the radial probe increased with a mean of 57 procedures/probe (17–147) during the period 2008–2014, compared to 77 (28–207) between 2015 and 2019 (p = 0.11; Mann–Whitney test).

FIGURE 4.

FIGURE 4

Evolution of radial‐endobronchial ultrasound (r‐EBUS) diagnostic strategy and performances over time

DISCUSSION

In this large single center cohort of more than 1500 r‐EBUS + VB planner procedures for peripheral lung cancer diagnosis, the positivity of the procedure was 74%, similar to other series. 11 , 12 Also, despite the small size of biopsy samples, molecular analysis and immunohistochemistry analysis for the assessment of PDL1 expression were possible in more than 80% of nonsquamous NSCLC cases, a success rate similar to that of previous reports. 13 , 14 , 15 This high diagnostic efficiency has remained stable since it was introduced in our center, indicating a short learning curve, as reported previously. 16 Moreover, as in other reports, complications of the procedure were also extremely rare. 3 , 11

Over the last 12 years, r‐EBUS associated with VB has become the first‐line endoscopic procedure for peripheral lung nodule diagnosis, increasing from 25% at the implementation of the procedure to more than 90% during the last 3 years. Several reasons explain why the r‐EBUS VB procedure has become the first endoscopic procedure over time.

First, the r‐EBUS technique we used is simplified, using virtual bronchoscopy planning without fluoroscopy, a 4 mm bronchoscope and the guide sheath procedure. As a result, the endoscopy was performed as an outpatient procedure under local anesthesia in nearly 80% of the cases, with more than 200 procedures a year during the last 4 years. In most studies, including metanalyses, 11 , 12 the majority of cases were performed under general anesthesia or sedation. Here, we show that a simplified r‐EBUS procedure performed under local anesthesia does not decrease the diagnostic yield. Along the same line, we chose to use VB planning alone without the endoscopic navigation component of VB in order to simplify the procedure and decrease its length and cost. Moreover, if the combination of electromagnetic navigation with r‐EBUS has been shown to slightly increase the diagnostic yield, 17 , 18 this appears time consuming, expensive, and complex to implement. For the same reason we did not use fluoroscopy, even if it has shown a slight benefit in the accuracy of sample collection. 19 Furthermore, fluoroscopy cannot visualize nodules with a diameter under 20 mm, and is probably not helpful in these cases. 20

Second, as previously published, VB plus r‐EBUS appears cost effective when compared to transthoracic biopsies (TTB), 21 mainly in reducing the risk of complications and therefore shortening the in‐patient hospitalization time. Moreover, even if the vulnerability of the r‐EBUS probe is well known, it can be used for 50–100 procedures, 16 , 17 in our experience, the median durability of the probe was 74 procedures per probe and improved over the study period.

Third, it is now accepted in the pulmonology community that standard bronchoscopy (i.e., without navigational bronchoscopy) is of marginal value for the diagnosis of peripheral nodules, with a low yield in most series. 5 , 6

Last, we systematically performed brush sampling in all procedures. Indeed, we believe that performing brush sampling for cytological analysis may also increase the positivity of the procedure. 22 , 23 In our series, brush sampling provided the only positive sample in 18% of cases. However, the sensitivity of brush sampling could not be evaluated in our study because the brush samples were not analyzed when the biopsy samples were positive. Moreover, if some studies report excellent results by using needle (especially for adjacent lesion to r‐EBUS), 24 , 25 we never use it because this procedure needs to be performed under fluoroscopy.

Therefore, with the development of the r‐EBUS technique in our center, a large majority of patients are now referred only a few days after the initial chest CT, without previous endoscopic exploration, a strategy that appears to be able to save resources and shorten the time to diagnosis, and therefore to treatment.

The strength of our study relies on its large size, and standardized procedure throughout the study period. In addition to its retrospective and single center nature, our study presents some limitations. As many as 86% of the patients in our series harbored a bronchus sign on CT scan, a situation that was associated with a r‐EBUS yield of more than 80%. This may suggest a selection bias either by the bronchoscopist who performed the procedure or the physicians who referred the patient, whereas other patients may have been preferentially referred to TTNA or surgery. Of note, the proportion of bronchus sign positive nodules but also the size of the nodules decreased over time in our series, with only a small decrease in the diagnostic rate of the procedure.

In future, new robotic bronchoscopy associated with r‐EBUS could be used in the most difficult cases such as pure ground‐glass opacities or nodules without bronchus signs. 26 , 27 However, the cost and the availability of this high‐level technology suggest that this new technique may not replace the simple r‐EBUS +VB planner procedure in the large majority of cases.

In conclusion, R‐EBUS and VB planner is an easy to perform and inexpensive procedure for the diagnosis of peripheral lung cancer that can be performed under local anesthesia. It has a high diagnostic efficiency and can be easily implemented in bronchoscopy units as a first‐line procedure, allowing histology, immunohistochemistry and molecular analysis.

CONFLICT OF INTEREST

MS and SL have received fees for consulting and training from Olympus. LP, DG, MDM, LT, HMP, ED, SB, NP, FG declare no conflict of interest related to the submitted work.

ACKNOWLEDGMENTS

We are grateful to Nikki Sabourin‐Gibbs, Rouen University Hospital, for her help in editing the manuscript.

Lachkar S, Perrot L, Gervereau D, De Marchi M, Morisse Pradier H, Dantoing E, et al. Radial‐EBUS and virtual bronchoscopy planner for peripheral lung cancer diagnosis: How it became the first‐line endoscopic procedure. Thorac Cancer. 2022;13(20):2854–2860. 10.1111/1759-7714.14629

REFERENCES

  • 1. Siegel RL, Miller KD, Jemal A. Cancer statistics, 2020. CA Cancer J Clin. 2020;70:7–30. [DOI] [PubMed] [Google Scholar]
  • 2. de Koning HJ, van der Aalst CM, de Jong PA, Scholten ET, Nackaerts K, Heuvelmans MA, et al. Reduced lung‐cancer mortality with volume CT screening in a randomized trial. N Engl J Med. 2020;382:503–13. [DOI] [PubMed] [Google Scholar]
  • 3. Han Y, Kim HJ, Kong KA, Kim SJ, Lee SH, Ryu YJ, et al. Diagnosis of small pulmonary lesions by transbronchial lung biopsy with radial endobronchial ultrasound and virtual bronchoscopic navigation versus CT‐guided transthoracic needle biopsy: a systematic review and meta‐analysis. PLoS One. 2018;13:e0191590. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 4. Heerink WJ, de Bock GH, de Jonge GJ, Groen HJM, Vliegenthart R, Oudkerk M. Complication rates of CT‐guided transthoracic lung biopsy: meta‐analysis. Eur Radiol. 2017;27:138–48. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 5. Baaklini WA, Reinoso MA, Gorin AB, Sharafkaneh A, Manian P. Diagnostic yield of Fiberoptic bronchoscopy in evaluating solitary pulmonary nodules. Chest. 2000;117:1049–54. [DOI] [PubMed] [Google Scholar]
  • 6. van ’t Westeinde SC, Horeweg N, Vernhout RM, HJM G, Lammers JJ, Weenink C, et al. The role of conventional bronchoscopy in the workup of suspicious CT scan screen‐detected pulmonary nodules. Chest. 2012;142:377–84. [DOI] [PubMed] [Google Scholar]
  • 7. Ost DE, Ernst A, Lei X, Kovitz KL, Benzaquen S, Diaz‐Mendoza J, et al. Diagnostic yield and complications of bronchoscopy for peripheral lung lesions. Results of the AQuIRE registry. Am J Respir Crit Care Med. 2016;193:68–77. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 8. Fielding D, Oki M. Technologies for targeting the peripheral pulmonary nodule including robotics. Respirology. 2020;25:914–23. [DOI] [PubMed] [Google Scholar]
  • 9. Kikuchi E. Endobronchial ultrasonography with guide‐sheath for peripheral pulmonary lesions. Eur Respir J. 2004;24:533–7. [DOI] [PubMed] [Google Scholar]
  • 10. Lachkar S, Guisier F, Roger M, Obstoy B, Bota S, Lerouge D, et al. Assessment of per‐endoscopic placement of fiducial gold markers for small peripheral lung nodules < 20 mm before stereotactic radiation therapy. Chest. 2018;153:387–94. [DOI] [PubMed] [Google Scholar]
  • 11. Sainz Zuñiga PV, Vakil E, Molina S, Bassett RL, Ost DE. Sensitivity of radial Endobronchial ultrasound‐guided bronchoscopy for lung cancer in patients with peripheral pulmonary lesions. Chest. 2020;157:994–1011. [DOI] [PubMed] [Google Scholar]
  • 12. Ali MS, Trick W, Mba BI, Mohananey D, Sethi J, Musani AI. Radial endobronchial ultrasound for the diagnosis of peripheral pulmonary lesions: a systematic review and meta‐analysis: R‐EBUS for diagnosing PPL: meta‐analysis. Respirology. 2017;22:443–53. [DOI] [PubMed] [Google Scholar]
  • 13. Guisier F, Salaün M, Lachkar S, Lamy A, Piton N, Obstoy B, et al. Molecular analysis of peripheral non‐squamous non‐small cell lung cancer sampled by radial EBUS: molecular analysis from r‐EBUS samples. Respirology. 2016;21:718–26. [DOI] [PubMed] [Google Scholar]
  • 14. Tsunoda A, Morikawa K, Inoue T, Miyazawa T, Hoshikawa M, Takagi M, et al. A prospective observational study to assess PD‐L1 expression in small biopsy samples for non‐small‐cell lung cancer. BMC Cancer. 2019;19:546. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 15. Kim I, Eom JS, Kim A, Lee CH, Lee G, Jo EJ, et al. Molecular analysis of small tissue samples obtained via transbronchial lung biopsy using radial probe endobronchial ultrasound. PLoS One. 2019;14:e0212672. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 16. Eom JS, Mok JH, Kim I, Lee MK, Lee G, Park H, et al. Radial probe endobronchial ultrasound using a guide sheath for peripheral lung lesions in beginners. BMC Pulm Med. 2018;18:137. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 17. Eberhardt R, Anantham D, Ernst A, Feller‐Kopman D, Herth F. Multimodality Bronchoscopic diagnosis of peripheral lung lesions: a randomized controlled trial. Am J Respir Crit Care Med. 2007;176:36–41. [DOI] [PubMed] [Google Scholar]
  • 18. Folch EE, Bowling MR, Pritchett MA, Murgu SD, Nead MA, Flandes J, et al. NAVIGATE 24‐month results: electromagnetic navigation bronchoscopy for pulmonary lesions at 37 centers in Europe and the United States. J Thorac Oncol. 2022;17:519–31. 10.1016/j.jtho.2021.12.008 [DOI] [PubMed] [Google Scholar]
  • 19. Asano F, Ishida T, Shinagawa N, Sukoh N, Anzai M, Kanazawa K, et al. Virtual bronchoscopic navigation without X‐ray fluoroscopy to diagnose peripheral pulmonary lesions: a randomized trial. BMC Pulm Med. 2017;17:184. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 20. Herth FJF, Eberhardt R, Becker HD, Ernst A. Endobronchial ultrasound‐guided transbronchial lung biopsy in fluoroscopically invisible solitary pulmonary nodules. Chest. 2006;129:147–50. [DOI] [PubMed] [Google Scholar]
  • 21. Steinfort DP, Liew D, Irving LB. Radial probe EBUS versus CT‐guided needle biopsy for evaluation of peripheral pulmonary lesions: an economic analysis. Eur Respir J. 2013;41:539–47. [DOI] [PubMed] [Google Scholar]
  • 22. Yu K‐L, Tsai TH, Ho CC, Liao WY, Lin CK, Hsu CL, et al. The value of radial endobronchial ultrasound‐guided bronchial brushing in peripheral non‐squamous non‐small cell lung cancer. Sci Rep. 2018;8:5837. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 23. Huang C‐T, Tsai Y‐J, Ho C‐C, Yu C‐J. Radial endobronchial ultrasound‐guided transbronchial biopsy for peripheral pulmonary malignancy: biopsy‐ or brushing‐first? BMC Pulm Med. 2019;19:193. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 24. Naso J, Bras J, Villamil C, Ionescu DN, Wang G, Shaipanich T, et al. Cytologic features and diagnostic value of PeriView FLEX transbronchial needle aspiration targeting pulmonary nodules. Cancer Cytopathol. 2020;128:333–40. [DOI] [PubMed] [Google Scholar]
  • 25. Sumi T, Shijubou N, Sawai T, Kamada K, Yamada Y, Nakata H, et al. Transbronchial needle aspiration with endobronchial ultrasonography and ultrathin bronchoscopy for peripheral pulmonary lesions. Respir Investig. 2021;59:766–71. [DOI] [PubMed] [Google Scholar]
  • 26. Yarmus L, Akulian J, Wahidi M, Chen A, Steltz JP, Solomon SL, et al. A prospective randomized comparative study of three guided bronchoscopic approaches for investigating pulmonary nodules. Chest. 2020;157:694–701. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 27. Simoff MJ, Pritchett MA, Reisenauer JS, Ost DE, Majid A, Keyes C, et al. Shape‐sensing robotic‐assisted bronchoscopy for pulmonary nodules: initial multicenter experience using the ion™ endoluminal system. BMC Pulm Med. 2021;21:322. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from Thoracic Cancer are provided here courtesy of Wiley

RESOURCES