Skip to main content
Materials logoLink to Materials
. 2022 Oct 21;15(20):7390. doi: 10.3390/ma15207390

Intermediate Crack Debonding of Externally Bonded FRP Reinforcement—Comparison of Methods

Paweł Tworzewski 1,*, Jeffrey K Alexy 2, Robert W Barnes 3
Editor: Luigi Solazzi
PMCID: PMC9606864  PMID: 36295463

Abstract

Many researchers around the world have made extensive efforts to study the phenomenon of fiber-reinforced polymer (FRP) debonding. Based on these efforts, code provisions and various models have been proposed for predicting intermediate crack (IC) debonding failure. The paper presents a comparison of seven selected models: fib bulletin 14 approach, Teng et al. model, Lu model, Seracino et al. model, Said and Wu model, Elsanadedy et al. model and ACI 440. The accuracy of each model was evaluated based on the test results of 58 flexural specimens with IC debonding failures of externally bonded (EB), carbon FRP plates or sheets found in the existing literature. The experimental database was prepared to include a wide range of parameters affecting the issue under consideration. A comparison of the measured and predicted load capacity values was made to evaluate the prediction accuracy of the considered models. The analysis included the limitation of the load capacity estimated based on IC debonding models as well as concrete crushing and FRP rupture types of failure. The results indicate that the latest models proposed for direct implementation in design guidelines—the Said and Wu model and the Elsanadedy et al. model—offer the best accuracy in predicting the load capacity. In contrast, the fib bulletin 14 approach shows a wide dispersion of predictions and a large proportion of highly overestimated results.

Keywords: debonding, FRP, RC beams, strengthening, failure modes, EBR

1. Introduction

External strengthening is the most popular method used to increase the load-bearing capacity of reinforced concrete (RC) members. Externally bonded (EB) systems include steel strengthening or composite strengthening. Fiber-reinforced polymer (FRP) composites are commonly used due to their strength parameters, corrosion resistance and light weight; the possibility of using any lengths without joints; and the ease of transport and application [1,2,3].

Several failure modes of RC beams strengthened with an externally bonded, tension-face FRP sheet can be distinguished. The first mechanism is intermediate crack (IC) debonding. The second mechanism consists of the rupture (R) of the composite reinforcement in the middle of the element. Other mechanisms include shear; crushing of compressive concrete (CC); and loss of anchorage at composite ends, which includes plate end (PE) debonding, concrete cover separation (CCS) and anchorage (A) failure [3,4].

Reinforced concrete members strengthened with bonded plates usually do not achieve flexural failure (concrete crushing or rupture of bonded plate). More typical are PE or IC debonding failures. Anticipating such failure is important for safe and efficient strengthening design. PE debonding failure can be eliminated with the use of proper anchorage (e.g., by using integrated FRP composite anchors [5] or FRP U-jackets). In the case of an IC debonding fracture that takes place in the adhesive layer, it can be eliminated by proper concrete surface preparation and application of good-quality adhesives [6]. However, when the IC debonding fracture occurs within the interfacial concrete, there are no efficient methods to avoid this failure [7,8]. Thus, it is critically important to control IC debonding failure. This is especially important for slender members strengthened with thin FRP plates or sheets [9].

As shown in Figure 1, each crack that intercepts a bonded plate causes local debonding, which increases with crack width development. At the same time, interfacial stresses between the FRP plate and the concrete in the area close to the crack increase. This can cause plate debonding when the plate axial force or axial strain reaches a critical value. This failure is initiated at each crack and propagates towards adjacent cracks or the nearest plate end. Therefore, the axial force that can be developed in bonded material is limited by IC debonding resistance. The ultimate tensile strain of FRP composites is very large and much greater than the ultimate tensile strain for typical reinforcing bars. After the existing steel reinforcement yields, additional stresses are mainly carried by the FRP plate, so typically steel has yielded when IC debonding occurs [10]. After interfacial shear stress reaches the maximum shear resistance, the bond degrades, which leads to a failure like the one shown in Figure 2.

Figure 1.

Figure 1

Intermediate crack (IC) [10].

Figure 2.

Figure 2

Localized debonding of FRP reinforcement in maximum moment region [11].

Many studies have been performed on this phenomenon, and further attempts are being made to develop new models for predicting the debonding moment in terms of PE and IC debonding failure [12,13,14,15,16]. Two experimental approaches can be distinguished in the study of debonding failure: testing small, properly prepared samples with a detailed analysis of selected parameters [13,17,18] or testing real-scale elements, which are often used to calibrate and test models [8,12,13,19,20,21]. Evaluations of debonding models have been reported by several researchers [8,13,17,19,21].

Since the EN 1992-1-1 standard revision is underway to include guidelines for strengthening existing concrete structures with carbon fiber reinforced polymers (CFRPs), the authors of the present paper examined the accuracy of selected existing IC debonding models. The models should be tested for accuracy and compared for the verification results to provide a source of guidelines for newly developed or modified standards. For this purpose, the fib bulletin 14 [3] third approach, Teng et al. model [22], Lu model [23], Seracino et al. model [24] and ACI 440 [25] models from design guidelines were used, as were the latest models proposed for direct implementation from the literature, namely the Said and Wu model [8] and the Elsanadedy et al. model [19]. As mentioned before, IC debonding failures are prevalent for externally bonded FRP, so it is crucial to predict them accurately when designing the strengthening of RC structures. For analysis, 58 flexural specimens with IC debonding failures of externally bonded CFRP plates or sheets were selected from the literature. The accuracy of each model was evaluated in two steps. First, the measured and predicted values of load capacity were compared. Then, the increase in experimental load capacity was compared to that estimated based on model calculations. To eliminate the influence of the safety factor, all the coefficients used were selected to obtain mean values from the guidelines for the models. Calibrating or testing models by comparing the load capacity results calculated without considering the constraints of other failure models does not accurately reflect design procedures. Therefore, unlike other analyses of this type, predicted strengths due to concrete crushing and FRP rupture were also adopted as limits. Specimens for which the failure mode was predicted incorrectly were identified.

2. IC Debonding Models Considered

fib bulletin 14:

The fib bulletin 14 [3] introduces three approaches, of which only the first and third approaches are suitable for design purposes. The second approach is too complicated to be applied in design; thus, it was omitted from further analysis. In the first approach, the anchorage and strain of the FRP are verified. The maximum force that can be developed in the FRP is calculated using Equation (1). This model includes the effect of the width ratio bf/b.

Nfa,max=αc1kckbbEftffctm (1)

where the kb geometry factor is calculated from Equation (2):

kb=1.062bfb1+bf4001 (2)

and α is a reduction factor typically equal to 0.9; c1 is a factor that can be calibrated, but for CFRP strips it is equal to 0.64; kc is a factor taking into account the consolidation of concrete, typically equal to 1.0; Ef is the modulus of elasticity of FRP; bf is the width of FRP; tf is the thickness of FRP; b is the width of beam; and fctm is the mean value of axial tensile strength of concrete.

In the third approach, the design shear force, Vd, in the RC member is limited. Including some assumptions, the following conditions are given:

εs1<εydVd0.95dbf(1+As1EsAfEf)fcbd (3)
εs1εydVd0.95dbffcbd (4)

where

fcbd=1.8fctkγc (5)

Teng et al. model [22]:

This model is presented in the Standards Australia design handbook [10] for calculating IC debonding resistance in beams. It includes the effect of the width ratio bf/b, and it is given by Equation (6).

(PIC)EB=αEBβpbfEftffcm (6)

where

βp=2bfb1+bfb (7)

and αEB is equal to 0.427 for the mean value; fcm is the mean value of the concrete compressive strength.

Lu model [23]:

This model also includes the effect of the width ratio bf/b. The equation is based on average strengths of materials. To balance safety and economy, it was modified and implemented in the Chinese concrete design code [6,26]. In this analysis, to avoid problems with overconservative results, the original Lu model was used, which is given by Equation (8):

εf,IC=(0.492Eftf0.086Ld)1.5βwfctm (8)
βw=2.25bfb1.25+bfb (9)

where Ld is the distance from the plate end to the section where the FRP plate is fully utilized.

In comparison to the others, the Lu model is more sensitive to the impact of concrete tensile strength. Said and Wu [8] claim that the concrete strength has little effect on the IC debonding based on the calibration results of the IC debonding model proposed in their work.

Seracino et al. [24]:

This model is presented in Standards Australia design handbook [10] as a generic IC debonding resistance model. Factors used in Equation (10) were calibrated based on push–pull tests [24,27]. This model can be used to calculate IC debonding resistance not only for EB plates but also for near-surface-mounted (NSM) plates.

PIC=αp0.85φf0.25fcm0.33Lper(EfAf)<ffAf (10)

where

αp={1.0 for mean0.85 for lower 95% confidence limit
φf=dpbp (11)
Lper=2dp+bp (12)

and Lper is calculated from Equation (12) based on Figure 3.

Figure 3.

Figure 3

Idealized failure plane [18].

Said and Wu model [8]:

Based on test results of 200 beams/slabs with IC debonding failures collected from the existing literature, Said and Wu calibrated and proposed this model to calculate the critical value for the FRP strain resulting in IC debonding failure, expressed by Equation (13). Based on this, an equation for debonding-moment capacity calculations was proposed with the necessary safety factors implemented. This model does not include the effect of the width ratio bf/b.

εdeb=0.23(fcm)0.2(Eftf)0.35 (13)

Elsanadedy et al. [19]:

This is the only model considered that was created using neural network modeling. The critical value for the FRP strain is expressed by Equation (14). This model includes the effect of the width ratio bf/b and is the only model to include the parameters of the tension steel reinforcement εy and ρs. Like the model presented above, an equation for debonding-moment capacity calculations with implemented safety factors was also proposed.

εfd=(2bf/b1+bf/b)0.1(εyntfEf)0.4(6.5+ntfEf135000)ρs0.05fcm0.1 (14)

where εy is the yield strain of the steel reinforcement; n is the number of layers of FRP.

ACI 440.R2-17 [25]:

The approach implemented in ACI 440.2R-17 is very simple. To avoid debonding, the FRP strain is limited to the value calculated from Equation (15). The model is based on a modified version of the Teng et al. [9] model. To simplify design calculation, the effect of the width ratio bf/b was replaced with a typical value and subsumed into the coefficient of 0.41.

εfd=0.41fcmnEftf0.9εfu (15)

The primary input variable that appears in every presented model is the FRP axial stiffness Eftf. The IC debonding resistance increases with the increasing value of these parameters. The interfacial fracture energy, represented by the concrete strength, is another important parameter that should not be omitted [8]. In the fib bulletin 14 [3] and Lu [23] models, this parameter is represented by fctm, while the remaining models use fcm. The power (exponent) of the strength value differentiates the influence of this parameter in individual models. As noted by Said and Wu [8], the effect of bf/b on debonding is quite controversial. This factor is a function of beam geometry and accounts for spreading shear stresses away from the edges of the FRP strip. The approaches implemented in the ACI 440.2R-17 [25] and Said and Wu [8] models neglect the width ratio bf/b. This approach is questioned by Benjamin [28], who showed that the ratio bf/b is important but insufficient and that the nature of the adhesive should be included in the calculation of limiting strain. Benjamin [28] points out that the Teng et al. model [22] appears to provide unconservative results for high-modulus adhesives. The Lu model [23] includes the Ld variable, i.e., the distance from the plate end to the section where the FRP plate is fully utilized. Said and Wu [8] point out that this parameter’s mechanical meaning is unclear. Since bonding length is guaranteed in a correctly designed element, the value of Ld cannot affect IC debonding. Elsanadedy et al. [19], based on an analysis carried out using an artificial neural network (ANN) model, determined that ntfEf is the most significant parameter, and εsy is second. Typically, steel yields before IC debonding occurs; therefore, there is a rationale for introducing this parameter into the model, but this has not been confirmed by other works. The impact of individual parameters is discussed by several authors [8,19,23,28].

2.1. Description of the Test Database Used in the Analysis

Fifty-eight beam specimens that failed by IC debonding were selected from the existing literature. All of these RC members were strengthened with an externally bonded CFRP plate or sheet reinforcement (EBR). The experimental database was selected to include a wide range of parameters (factors describing the distribution of key parameters are shown in Table 1):

  • Span length, L;

  • Slenderness ratio, L/d;

  • Compressive strength of concrete, fc;

  • Yield strength of reinforcement, ff;

  • Modulus of elasticity of steel, Es;

  • Tensile strength of the FRP, Ef;

  • Modulus of elasticity of FRP, fy;

  • Flexural steel reinforcement ratio, ρs = As1/bd, where As1 is the area of steel tension reinforcement;

  • Flexural FRP reinforcement ratio, ρf = Af/bdf, where Af is the area of FRP tension reinforcement;

  • Ratio of the width of the FRP sheet to the width of the concrete section, bf/b.

Table 1.

Parameters of specimens selected for analysis.

L L/d fc ff Ef fy Es ρs ρf bf/b
(mm) (MPa) (MPa) (MPa) (MPa) (MPa)
Mean value 3156 11.45 39.1 2852 224,000 446 197,600 0.011 0.0012 0.54
Median value 3000 11.11 42.8 2915 227,000 435 200,000 0.008 0.0011 0.45
Standard deviation 1068 2.00 13.3 821 80,600 75.4 9005 0.006 0.0009 0.36
Maximum value 4800 15.56 57.7 3900 400,000 552 207,500 0.025 0.0044 1.00
Minimum value 1500 7.55 18 846 45,000 330 180,000 0.004 0.0001 0.09

Moreover, to account for the effect of scale, RC members with different spans and slenderness were selected. Sixteen out of the fifty-eight members have a T-shaped cross section. Loading configurations vary from three- or four-point bending members to the simulation of uniformly distributed load. The type of internal steel reinforcing bars also varied (smooth bars, deformed bars). Eleven beams were subject to loading during the installation of the FRP plate.

2.2. Assumptions for Calculations

To determine the value of the load-carrying capacity of flexural members, the following assumptions were made:

  • Plane sections remain plane during bending [3,25].

  • Steel is linearly elastic, perfectly plastic [3,25].

  • The stress–strain relationship for FRP materials is linear [3,25].

  • The average values for steel and concrete strength were used in calculation.

  • An equivalent rectangular stress distribution for concrete is used (Whitney stress block [25]). For debonding failure, α1—the multiplier on fc to determine the intensity of an equivalent rectangular stress distribution for concrete given by Equation (16)—and β1—the ratio of the depth of the equivalent rectangular stress block to the depth of the neutral axis—were used.

  • For concrete crushing and rupture of FRP, bending moment capacity was calculated based on the fib bulletin 14 [3] approach.

α1=3εcεcεc23β1εc2 (16)

where εc is the maximum strain of unconfined concrete equal to 0.002.

To reflect the procedures used in the FRP strengthening design, the predicted strength of flexural members was also limited by concrete crushing and FRP rupture failure modes. In analyses found in the literature, such an approach is not used, although it more closely reflects reality. If the IC debonding model is not the limiting failure mode, it is ignored. The predicted increase in strength, ΔMpred, was calculated as the difference between the predicted strength of the strengthened beam and the predicted strength of the beam without strengthening. The measured/experimental increase in strength, ΔMexp, was calculated as the difference between the measured strength of the strengthened beam and the measured strength of a companion control beam without strengthening.

3. Results

All results are reported in Table 2. Additional markings are used where the predicted failure model differs from IC debonding: CC for crushing of concrete in compression and R for rupture of FRP plate. Comparisons of the measured and predicted flexural capacity are presented graphically for each model in Figure 4, Figure 5, Figure 6, Figure 7, Figure 8, Figure 9 and Figure 10. Statistical analysis of the results is illustrated graphically in Figure 11 using box plots with values reported in Table 3.

Table 2.

Parameters of specimens selected for analysis.

References Specimen
ID
Experimental fib Teng et al. Lu Seracino et al. Said and Wu Elsanadedy et al. ACI 440
Mexp ΔMexp Mpred ΔMpred Mpred ΔMpred Mpred ΔMpred Mpred ΔMpred Mpred ΔMpred Mpred ΔMpred Mpred ΔMpred
(kNm) (kNm) (kNm) (kNm) (kNm) (kNm) (kNm) (kNm) (kNm) (kNm) (kNm) (kNm) (kNm) (kNm) (kNm) (kNm)
El Hacha and
Rizkalla
[29]
B2a 40.3 5.6 32.3 7.6 38.8 14.1 39.9 15.3 32.1 7.5 39.9 15.2 40.6 16.0 33.8 9.1
B2b 40.3 5.6 32.3 7.6 38.8 14.1 39.9 15.3 32.1 7.5 39.9 15.2 40.6 16.0 33.8 9.1
B4a 44.2 9.5 40.4 15.7 49.2 24.5 53.0 28.4 37.4 12.7 47.8 23.2 45.9 21.3 34.8 10.2
Jung et al.
[30]
CPL-50-BOND 38.5 9.1 57.2 34.8 36.9 14.5 37.0 14.6 24.1 1.8 41.4 19.1 42.0 19.7 36.1 13.7
SH-BOND 43.3 13.8 37.3 14.9 33.9 11.5 37.3 14.9 27.7 5.3 40.0 17.7 37.9 15.5 36.2 13.8
Reed et al.
[10]
B1 111.7 18.0 159.7 R 72.4 108.3 21.0 111.8 24.5 94.2 6.9 110.2 22.9 107.5 20.2 109.7 22.4
B2 115.5 21.8 159.7 R 72.4 108.3 21.0 111.8 24.5 94.2 6.9 110.2 22.9 107.5 20.2 109.7 22.4
B3 112.1 18.4 159.7 R 72.4 108.3 21.0 111.8 24.5 94.2 6.9 110.2 22.9 107.5 20.2 109.7 22.4
B4 115.8 22.1 159.7 R 72.4 108.3 21.0 111.8 24.5 94.2 6.9 110.2 22.9 107.5 20.2 109.7 22.4
B5 112.1 18.4 159.7 R 72.4 108.3 21.0 111.8 24.5 94.2 6.9 110.2 22.9 107.5 20.2 109.7 22.4
B6 114.2 20.5 159.7 R 72.4 108.3 21.0 111.8 24.5 94.2 6.9 110.2 22.9 107.5 20.2 109.7 22.4
B7 119.7 26.2 172.4 85.0 111.7 24.3 115.4 27.9 95.4 8.0 115.5 28.1 113.7 26.3 113.5 26.0
Kotynia et al.
[31,32]
B-08/s 72.0 - 63.2 21.5 61.5 19.8 60.4 18.8 48.1 6.4 70.4 28.8 68.8 27.1 61.4 19.8
B0-08/s 72.0 - 63.8 22.0 62.0 20.1 61.5 19.6 48.5 6.6 71.0 29.1 69.2 27.3 62.3 20.4
BF-06/s 59.9 - 49.7 21.3 48.2 19.7 48.3 19.9 35.4 7.0 57.0 28.5 55.1 26.6 48.1 19.7
BF-04/0.5s 33.6 - 39.2 R 20.7 30.4 11.9 30.2 11.7 22.8 4.4 32.6 14.1 31.8 13.3 28.6 10.2
B-08S 52.8 - 66.6 25.1 56.0 14.5 55.4 13.9 46.0 4.5 59.7 18.2 59.4 17.8 54.0 12.5
B-08M 77.0 - 63.3 21.4 72.2 30.2 74.0 32.0 53.6 11.6 98.5 56.5 97.0 55.0 78.9 36.9
Tumialan
et al. [33]
A1 77.6 20.6 81.2 7.9 86.6 CC 13.3 86.6 CC 13.3 79.8 6.4 86.6 CC 13.3 86.6 CC 13.3 86.6 CC 13.3
A2 104.9 48.0 82.6 9.3 91.7 18.4 96.1 22.7 80.8 7.4 96.2 CC 22.9 96.2 CC 22.9 96.1 22.8
A6 65.1 8.1 80.6 CC 7.3 80.6 CC 7.3 80.6 CC 7.3 77.9 4.6 80.6 CC 7.3 80.6 CC 7.3 80.6 CC 7.3
A7 77.6 20.6 86.6 CC 13.3 86.6 CC 13.3 86.6 CC 13.3 78.1 4.7 86.6 CC 13.3 86.6 CC 13.3 84.9 11.6
C1 77.6 20.6 81.2 7.9 86.6 CC 13.3 86.6 CC 13.3 79.8 6.4 86.6 CC 13.3 86.6 CC 13.3 86.6 CC 13.3
Siddiqui [34] BFS1 90.6 16.6 59.7 11.5 70.9 22.7 73.0 24.8 56.8 8.6 87.8 39.5 78.0 29.7 77.3 29.1
Yeong-Soo
and Chadon
[35]
R20 31.5 8.4 24.4 R 2.0 24.4 R 2.0 24.4 R 2.0 24.2 1.8 24.4 R 2.0 24.4 R 2.0 23.6 1.2
R2L 32.7 9.6 24.4 R 2.0 24.4 R 2.0 24.4 R 2.0 24.4 2.0 24.4 R 2.0 24.4 R 2.0 23.6 1.2
R2H 39.9 16.8 24.4 R 2.0 24.4 R 2.0 24.4 R 2.0 24.4 R 2.0 24.4 R 2.0 24.4 R 2.0 23.6 1.2
R30 46.0 9.8 32.6 CC 1.3 32.6 CC 1.3 32.6 CC 1.3 32.6 CC 1.3 32.6 CC 1.3 32.6 CC 1.3 32.4 1.0
R3L 46.8 10.6 32.5 CC 1.1 32.5 CC 1.1 32.5 CC 1.1 32.5 CC 1.1 32.5 CC 1.1 32.5 CC 1.1 32.4 1.0
R3H 43.7 7.5 32.4 CC 1.1 32.4 CC 1.1 32.4 CC 1.1 32.4 CC 1.1 32.4 CC 1.1 32.4 CC 1.1 32.4 1.0
Bonacci and Maalej
[36]
B2 192.4 50.0 155.1 22.3 174.9 42.1 171.3 38.5 146.7 13.9 185.4 CC 52.6 185.4 CC 52.6 170.9 38.1
Mazzotti and Savoia
[37]
TN3 138.5 27.2 146.9 55.6 131.4 40.1 138.3 47.0 101.4 10.1 142.5 51.2 138.1 46.8 134.8 43.5
TN5 153.3 42.0 110.8 19.4 132.7 41.4 144.7 53.4 106.4 15.1 162.0 70.7 145.9 54.6 158.4 67.0
TN8 154.4 43.1 110.5 19.3 132.3 41.0 143.7 52.5 106.1 14.9 161.4 70.2 145.7 54.4 156.9 65.7
Maalej
and Leong [38]
A3 19.4 4.2 16.9 CC 3.4 16.9 CC 3.4 16.9 CC 3.4 16.1 2.6 16.9 CC 3.4 16.9 CC 3.4 16.9 CC 3.4
A4 18.9 3.7 16.9 CC 3.4 16.9 CC 3.4 16.9 CC 3.4 16.1 2.6 16.9 CC 3.4 16.9 CC 3.4 16.9 CC 3.4
A5 21.9 6.7 17.7 4.3 19.0 CC 5.5 19.0 CC 5.5 16.7 3.2 19.0 CC 5.5 19.0 CC 5.5 19.0 CC 5.5
A6 21.5 6.3 17.7 4.3 19.0 CC 5.5 19.0 CC 5.5 16.7 3.2 19.0 CC 5.5 19.0 CC 5.5 19.0 CC 5.5
B3 131.8 30.7 122.1 14.8 134.6 CC 27.3 134.6 CC 27.3 115.7 8.3 134.6 CC 27.3 134.6 CC 27.3 134.6 CC 27.3
B4 130.2 29.1 122.1 14.8 134.6 CC 27.3 134.6 CC 27.3 115.7 8.3 134.6 CC 27.3 134.6 CC 27.3 134.6 CC 27.3
B5 147.4 46.3 125.2 17.9 143.2 35.9 150.2 42.8 116.9 9.6 151.8 CC 44.4 151.8 CC 44.4 148.4 41.1
B6 142.2 41.1 125.2 17.9 143.2 35.9 150.2 42.8 116.9 9.6 151.8 CC 44.4 151.8 CC 44.4 148.4 41.1
C3 522.3 106.7 454.7 23.5 514.1 82.9 533.9 CC 102.6 438.1 6.9 533.9 CC 102.6 533.9 CC 102.6 526.8 95.6
C4 535.4 119.8 454.7 23.5 514.1 82.9 533.9 CC 102.6 438.1 6.9 533.9 CC 102.6 533.9 CC 102.6 526.8 95.6
C5 520.1 104.4 456.6 25.4 533.4 102.2 560.0 128.8 436.3 5.1 599.3 CC 168.0 599.3 CC 168.0 564.4 133.2
Mostafa and
Razaqpur [39]
B1-F2-N 172.5 38.3 108.4 22.8 125.7 40.1 135.4 49.8 99.6 14.0 147.4 61.8 127.1 41.5 145.5 59.9
B2-F2-N 153.8 30.8 108.4 22.8 125.7 40.1 135.4 49.8 99.6 14.0 147.4 61.8 127.1 41.5 145.5 59.9
B1-F4-N 189.8 66.8 117.7 32.1 141.6 56.0 154.0 68.4 105.5 19.9 182.2 96.6 153.9 68.3 170.0 84.4
B2-F4-N 159.8 36.8 117.7 32.1 141.6 56.0 154.0 68.4 105.5 19.9 182.2 96.6 153.9 68.3 170.0 84.4
B1-F4-N b90 150.0 27.0 136.0 50.4 118.2 32.6 123.3 37.7 94.1 8.5 124.1 38.5 114.4 28.7 120.4 34.8
B1-F8-N b90 161.3 38.3 156.2 70.5 131.3 45.7 137.1 51.4 98.1 12.4 146.1 60.5 136.8 51.2 134.8 49.2
Alfano
et al. [20]
S1 42.5 13.0 50.0 24.8 45.2 20.0 38.9 13.7 31.5 6.3 55.5 30.3 55.8 R 30.6 39.1 13.9
S2 43.5 14.0 50.0 24.8 45.2 20.0 38.9 13.7 31.5 6.3 55.5 30.3 55.8 R 30.6 39.1 13.9
S3 62.0 20.5 50.0 13.4 57.0 20.4 50.5 13.9 42.6 6.0 61.9 CC 25.3 61.9 CC 25.3 49.2 12.6
S5 37.6 15.6 32.6 12.4 36.9 16.7 31.0 10.9 25.5 5.3 42.6 CC 22.4 42.6 CC 22.4 31.2 11.1
S6 36.0 14.0 32.6 12.4 36.9 16.7 31.0 10.9 25.5 5.3 42.6 CC 22.4 42.6 CC 22.4 31.2 11.1
S7 48.4 13.2 32.6 3.6 46.4 17.4 40.3 11.4 34.4 5.5 45.3 CC 16.3 45.3 CC 16.3 38.7 9.7
S8 44.4 9.2 32.6 3.6 46.4 17.4 40.3 11.4 34.4 5.5 45.3 CC 16.3 45.3 CC 16.3 38.7 9.7

CC predicted failure mode—crushing of concrete in compression. R predicted failure mode—rupture of FRP plate.

Figure 4.

Figure 4

Measured flexural strength versus fib bulletin 14 prediction.

Figure 5.

Figure 5

Measured flexural strength versus Teng et al. model prediction.

Figure 6.

Figure 6

Measured flexural strength versus Lu model prediction.

Figure 7.

Figure 7

Measured flexural strength versus Seracino et al. model prediction.

Figure 8.

Figure 8

Measured flexural strength versus Said and Wu model prediction.

Figure 9.

Figure 9

Measured flexural strength versus Elsanadedy et al. model prediction.

Figure 10.

Figure 10

Measured flexural strength versus ACI 440 prediction.

Figure 11.

Figure 11

Comparison of deviation of predicted results—box plots.

Table 3.

Comparison of deviation of predicted results.

(MexpMpred)/Mexp
(%)
fib Teng
et al.
Lu
et al.
Seracino
et al.
Said
and Wu
Elsanadedy
et al.
ACI 440
Mean value 6.0% 8.1% 7.7% 23.7% 1.1% 3.5% 8.7%
Median 12.9% 6.4% 8.5% 23.6% 1.6% 4.1% 10.2%
Maximum value 38.9% 38.9% 38.9% 44.4% 38.9% 38.9% 41.0%
Minimum value −48.5% −23.9% −23.9% −19.8% −30.7% −31.3% −23.9%
Standard deviation 24.4% 12.3% 12.3% 12.0% 14.2% 14.8% 12.1%
Incorrect failure mode prediction 29% 28% 31% 7% 48% 52% 16%

The following criteria can be used to assess the accuracy of the models with respect to the presented results:

  • Plots of measured versus predicted values (Figure 4, Figure 5, Figure 6, Figure 7, Figure 8, Figure 9, Figure 10, Figure 12, Figure 13, Figure 14, Figure 15, Figure 16, Figure 17 and Figure 18)—the greatest accuracy is achieved when the points are closest to the line of equality (red). Unconservative predictions are located below this line, while conservative predictions are above this line.

  • Boxplots (Figure 11 and Figure 19)—smaller interquartile range (length of box) indicates better accuracy. Horizontal location of the box to the left indicates that the model is less conservative; a location to the right indicates that the model is more conservative.

  • Summary statistics (Table 3 and Table 4)—mean value, median, standard deviation, maximum and minimum values, incorrect failure mode prediction—the closer to 0, the better the accuracy of the model.

  • It is readily apparent that the fib bulletin 14 approach shows a wide dispersion (greatest standard deviation, 24.4%) of predictions relative to measured values (Figure 5) and a large proportion of highly overestimated results, which can be unsafe. The interquartile range is the largest. Similar problems with all fib bulletin 14 approaches were reported by others [8,20]. The Teng et al. and Lu models give similar results and have a slightly greater proportion of values on the conservative side. However, these two models are less accurate than the Elsanadedy et al. and Said and Wu models. The Seracino et al. model was calibrated based on push–pull tests. Such tests were meant to study the performance of the strength of the bond and transfer of the force at the FRP–concrete interface, which can also be called the shear method of testing. The results obtained in this way differ from those obtained in the tests of actual reinforced flexural elements, resulting in the Seracino et al. model being very conservative. Based on the mean value (1.1%) and median (1.6%), the best predictability was obtained from the Said and Wu model; the dispersion as measured by the standard deviation is slightly greater than several others, but the interquartile range is one of the smallest. Furthermore, 48% of the predicted values were higher than the measured capacity, including those for which crushing of concrete (CC) or rupture (R) of the FRP plate was predicted to be the failure mode. Similar behavior can be observed in the case of the Elsanadedy et al. model because IC debonding failure often occurred at almost the same load as the other failure modes. The strength values calculated for the various failure modes can be very similar. It can be assessed that the Elsanadedy et al. model takes second place after the Said and Wu model. The simple ACI 440 model is more conservative than the two mentioned above but exhibits a smaller relative error (standard deviation 12.1%). The accuracy of this model is slightly worse than that of the Teng et al. and Lu et al. models.

Figure 12.

Figure 12

Measured increase in flexural strength versus fib bulletin 14 prediction.

Figure 13.

Figure 13

Measured increase in flexural strength versus Teng et al. model prediction.

Figure 14.

Figure 14

Measured increase in flexural strength versus Lu model prediction.

Figure 15.

Figure 15

Measured increase in flexural strength versus Seracino et al. model prediction.

Figure 16.

Figure 16

Measured increase in flexural strength versus Said and Wu model prediction.

Figure 17.

Figure 17

Measured increase in flexural strength versus Elsanadedy et al. model prediction.

Figure 18.

Figure 18

Measured increase in flexural strength versus ACI 440 prediction.

Figure 19.

Figure 19

Comparison of predicted increase in flexural strength—box plots.

Table 4.

Comparison of deviation of predicted results.

Mexp − ΔMpred)/ΔMexp
(%)
fib Teng
and
Cheng
Lu
et al.
Seracino
et al.
Said an Wu Elsanadedy
et al.
ACI 440
Mean value −16.6% −2.0% −6.7% 61.3% −25.7% −15.4% 1.0%
Median 33.5% 4.8% −0.1% 66.9% −17.5% −5.8% 0.5%
Maximum value 89.3% 89.3% 89.3% 95.2% 89.3% 89.3% 92.9%
Minimum value −301.5% −158.6% −198.9% −34.3% −173.4% −187.3% −129.7%
Standard deviation 118.2% 54.8% 60.2% 27.9% 69.0% 64.1% 48.6%
Incorrect failure mode prediction 29% 28% 31% 7% 48% 52% 16%

The second portion of the analysis compares the measured increase in strength (based only on experimental values) and predicted increase in strength (based only on calculated values). Due to the lack of results for unstrengthened control beams, the Kotynia and Kamińska [31,32] test results were not included in this comparison. From the design side, this approach checks which model results in the most accurate determination of the increase in the load capacity of an element after strengthening. The dispersion of results in this analysis is much greater than when only considering the total strength. This is because the relative accuracy of the predicted increase in strength is not biased by the portion of the strength attributable to the unstrengthened specimen. A graphical comparison of the values obtained for each model is shown in Figure 12, Figure 13, Figure 14, Figure 15, Figure 16, Figure 17 and Figure 18, while the values are reported in Table 2.

In Figure 12, Figure 13, Figure 14, Figure 15, Figure 16, Figure 17 and Figure 18, the results for which the model predicted a different failure mode from those observed in the tests are additionally marked. Statistical analysis of the results is presented graphically in Figure 19 with values reported in Table 4. When measuring the increase in strength, the predicted values closest to the measured strength increase are obtained using the ACI 440 method and the Teng et al. method. Comparing the models that fared best in the previous comparison, the Elsanadedy et al. model gives better results in predicting increased flexural strength than the Said and Wu model. This is indicated by the lesser mean value, median and standard deviation. The Seracino et al. model exhibits the smallest dispersion, but it is very conservative. For all models except those of Said and Wu and Elsanadedy et al., incorrect failure mode predictions are on the conservative side.

4. Conclusions

In this study, the main aim was to investigate accuracy of selected IC debonding models: fib Bulletin 14 [3] third approach, Teng et al. model [16], Lu model [17], Seracino et al. model [18], Said and Wu model [8], Elsanadedy et al. model [13] and ACI 440 [19]. The analysis was carried out to indicate which of the considered models is the best for newly developed standards. Several conclusions are supported by the research described in this paper:

  1. If the mean values of the deviation of the predicted load capacity from the measured value are compared, the Said and Wu (2008) model gives the best results (mean error value 1.1%), but compared to most other methods, the standard deviation is quite high. The Elsanadedy et al. model, which is one of the most complex compared to other investigated models, is next best (mean error value 3.5%). The authors of both models also provide modified versions that include appropriate safety margins. Therefore, both models are ready to be implemented in the standards and are noteworthy.

  2. The newer models (Said and Wu and Elsanadedy et al.), despite employing quite different approaches, provide very similar results and accuracy.

  3. Two models distinguished by their simplicity and ease of application—the ACI 440 and the Said and Wu model—give good results compared to other more complex models.

  4. The best match between the predicted and measured increase in strength was obtained using the ACI 440 method application (mean error value 1.0%).

  5. The fib bulletin 14 (fib 2001) approach features a wide dispersion and a large share of highly overestimated results, which can be unsafe.

  6. The largest share of incorrect failure mode predictions was observed for the Elsanadedy et al. model (52%) and the Said and Wu model (48%). This means that the values of the load capacity estimated with the use of these models exceeded those determined for flexural failures. The limitations of the calculated value of the load capacity introduced on this basis affect the results of the model accuracy analysis.

  7. Most studies presented in the literature do not give full results of materials testing. This mainly applies to FRP plate strength parameters or even test results for unreinforced beams. Therefore, the available results database is still not sufficient for the creation of a fully effective IC debonding model. More complex tests of strengthened RC beams are needed. The article indicates sources with flexural test data collected from the existing literature, which can be used in other works to test and calibrate debonding models.

  8. The analysis presented in the article was carried out with the use of models in design in mind. Therefore, a broader study of the parameters that appear in individual models has not been undertaken. The focus is on accuracy and simplicity, which are the two most important guidelines for standard development.

Author Contributions

Conceptualization, P.T. and R.W.B.; methodology, P.T., J.K.A. and R.W.B.; software, P.T. and J.K.A.; validation, P.T., J.K.A. and R.W.B.; formal analysis, P.T.; investigation, P.T.; resources, P.T. and R.W.B.; data curation, P.T. and J.K.A.; writing—original draft preparation, P.T.; writing—review and editing, P.T. and R.W.B.; supervision, R.W.B. All authors have read and agreed to the published version of the manuscript.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

Not applicable.

Conflicts of Interest

The authors declare no conflict of interest.

Funding Statement

The tests were implemented thanks to the financial support of the Kielce University of Technology within the framework of the statutory work No. 02.0.13.00/1.02.001, SUBB. BKBB. 22.001.

Footnotes

Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

References

  • 1.Schiebel S., Parretti R., Nanni A., Huck M. Strengthening and Load Testing of Three Bridges in Boone County, Missouri. Pract. Period. Struct. Des. Constr. 2002;7:156–163. doi: 10.1061/(ASCE)1084-0680(2002)7:4(156). [DOI] [Google Scholar]
  • 2.Carmichael B.W., Barnes R.W. Repair of the Uphapee Creek Bridge with FRP Laminates. Highway Research Center, Auburn University; Auburn, AL, USA: 2005. No. RP-930-466-2. [Google Scholar]
  • 3.International Federation for Structural Concrete (FIB) Externally Bonded FRP Reinforcement for RC Structures. International Federation for Structural Concrete (FIB); Lausanne, Switzerland: 2001. Bulletin 14. [Google Scholar]
  • 4.Tworzewski P., Bacharz K., Michałowska-Maziejuk D. Anchorage Systems in FRP-Strengthened Reinforced Concrete. JCEEA. 2018;65:101–110. [Google Scholar]
  • 5.McGuirk G.N., Breña S.F. Development of Anchorage System for FRP Strengthening Applications Using Integrated FRP Composite Anchors. Department of Civil and Environmental Engineering, University of Massachusetts; Amherst, MA, USA: 2012. Report Submitted to the Concrete Research Council of the ACI Foundation. [Google Scholar]
  • 6.Mostofinejad D., Mahmoudabadi E. Grooving as Alternative Method of Surface Preparation to Postpone Debonding of FRP Laminates in Concrete Beams. J. Compos. Constr. 2010;14:804–811. doi: 10.1061/(ASCE)CC.1943-5614.0000117. [DOI] [Google Scholar]
  • 7.Ye L.P., Lu X.Z., Chen J.F. Design Proposals for the Debonding Strengths of FRP Strengthened RC Beams in the Chinese Design Code; Proceedings of the International Symposium on Bond Behaviour of FRP in Structures (BBFS 2005); Hong Kong, China. 7–9 December 2005; pp. 45–54. [Google Scholar]
  • 8.Said H., Wu Z. Evaluating and Proposing Models of Predicting IC Debonding Failure. J. Compos. Constr. 2008;12:284–299. doi: 10.1061/(ASCE)1090-0268(2008)12:3(284). [DOI] [Google Scholar]
  • 9.Teng J.G., Smith S.T., Yao J., Chen J.F. Intermediate crack-induced debonding in RC beams and slabs. Constr. Build. Mater. 2003;17:447–462. doi: 10.1016/S0950-0618(03)00043-6. [DOI] [Google Scholar]
  • 10.Standards Australia . Design Handbook for RC Structures Retrofitted with FRP and Metal Plates: Beams and Slabs. Standards Australia; Sydney, Australia: 2008. HB 305-2008. [Google Scholar]
  • 11.Reed M.W., Barnes R.W., Schindler A.K., Lee H.-W. Fiber-Reinforced Polymer Strengthening of Concrete Bridges that Remain Open to Traffic. ACI Struct. J. 2005;102:823–831. [Google Scholar]
  • 12.Thamrin R., Zaidir Z., Desharma S. Debonding Failure Analysis of Reinforced Concrete Beams Strengthened with CFRP Plates. Polymers. 2021;13:2738. doi: 10.3390/polym13162738. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 13.Abed R.J., Mashrei M.A., Sultan A.A. Evaluating Flexural Strength of RC Beams Strengthened by CFRP using Different Analytical Models. Civ. Environ. Eng. 2021;17:465–475. doi: 10.2478/cee-2021-0049. [DOI] [Google Scholar]
  • 14.Al-Saawani M.A., Al-Negheimish A.I., El-Sayed A.K., Alhozaimy A.M. Finite Element Modeling of Debonding Failures in FRP-Strengthened Concrete Beams Using Cohesive Zone Model. Polymers. 2022;14:1889. doi: 10.3390/polym14091889. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 15.Milani G., Grande E., Bertolesi E., Rotunno T., Fagone M. Debonding mechanism of FRP strengthened flat surfaces: Analytical approach and closed form solution. Constr. Build. Mater. 2021;302:124144. doi: 10.1016/j.conbuildmat.2021.124144. [DOI] [Google Scholar]
  • 16.Berardi V.P. Fracture Failure Modes in Fiber-Reinforced Polymer Systems Used for Strengthening Existing Structures. Appl. Sci. 2021;11:6344. doi: 10.3390/app11146344. [DOI] [Google Scholar]
  • 17.Sayed A.M. Modelling of bond strength of FRP-concrete interface on the basis of a comprehensive experimental database. J. Eng. Sci. Technol. 2019;14:3309–3326. [Google Scholar]
  • 18.Min X., Zhang J., Wang C., Song S., Yang D. Experimental Investigation of Fatigue Debonding Growth in FRP-Concrete Interface. Materials. 2020;13:1459. doi: 10.3390/ma13061459. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 19.Elsanadedy H.M., Abbas H., Al-Salloum Y.A., Almusallam T.H. Prediction of Intermediate Crack Debonding Strain of Externally Bonded FRP Laminates in RC Beams and One-Way Slabs. J. Compos. Constr. 2014;18:04014008. doi: 10.1061/(ASCE)CC.1943-5614.0000462. [DOI] [Google Scholar]
  • 20.Alfano G., Cicco F.D., Prota A. Intermediate Debonding Failure of RC Beams Retrofitted in Flexure with FRP: Experimental Results versus Prediction of Codes of Practice. J. Compos. Constr. 2012;16:185–195. doi: 10.1061/(ASCE)CC.1943-5614.0000250. [DOI] [Google Scholar]
  • 21.Lu X.Z., Teng J.G., Ye L.P., Jiang J.J. Intermediate Crack Debonding in FRP-Strengthened RC Beams: FE Analysis and Strength Model. J. Compos. Constr. 2007;11:161–174. doi: 10.1061/(ASCE)1090-0268(2007)11:2(161). [DOI] [Google Scholar]
  • 22.Teng J.G., Chen J.F., Smith S.T., Lam L. FRP Strengthening RC Structures. John Wiley and Sons Ltd.; Chichester, UK: 2002. [Google Scholar]
  • 23.Lu X.Z. Ph.D. Thesis. Tsinghua University; Beijing, China: 2004. Studies of FRP-Concrete Interface. [Google Scholar]
  • 24.Seracino R., Raizal Saifulnaz M.R., Oehlers D.J. Generic Debonding Resistance of EB and NSM Plate-to-Concrete Joints. J. Compos. Constr. 2007;11:62–70. doi: 10.1061/(ASCE)1090-0268(2007)11:1(62). [DOI] [Google Scholar]
  • 25.ACI Committee 440 . Guide for the Design and Construction of Externally Bonded FRP Systems for Strengthening Concrete Structures. American Concrete Institute (ACI); Farmington Hills, MI, USA: 2017. ACI 440.2R-17. [Google Scholar]
  • 26.China Association for Engineering Construction Standardization (CECS146) Technical Specification for Strengthening Concrete Structure with Carbon Fiber Reinforced Polymer Laminate. China Planning Press; Beijing, China: 2003. [Google Scholar]
  • 27.Seracino R., Jone N.M., Ali M.S.M., Page M.W., Oehlers D.J. Bond Strength of Near-Surface Mounted FRP Strip-to-Concrete Joints. J. Compos. Constr. 2007;11:401–409. doi: 10.1061/(ASCE)1090-0268(2007)11:4(401). [DOI] [Google Scholar]
  • 28.Benjamin Z.R. Master’s Thesis. Pittsburgh University; Pittsburgh, PA, USA: 2005. Effect of Adhesive Stiffness and CFRP Geometry on the Behavior of Externally Retrofit Measures Subject to Monotonic Loads. [Google Scholar]
  • 29.El-Hacha R., Rizkalla S.H. Near-Surface-Mounted Fiber-Reinforced Polymer Reinforcements for Flexural Strengthening of Concrete Structures. ACI Struct. J. 2004;101:717–726. [Google Scholar]
  • 30.Jung W.-T., Park Y.-H., Park J.-S., Kang J.-Y., You Y.-J. Experimental Investigation on Flexural Behavior of RC Beams Strengthened by NSM CFRP Reinforcements; Proceedings of the 7th International Symposium on Fiber-Reinforced Polymer (FRP) Reinforcement for Concrete Structures; Kansas City, MI, USA. 6–9 November 2005; pp. 795–806. [Google Scholar]
  • 31.Kotynia R., Kaminska M.E. Experimental Research on RC Beams Strengthened with CFRP Strips. Department of Concrete Structures, Technical University of Lodz; Lodz, Poland: 2000. Report No. 9. [Google Scholar]
  • 32.Kotynia R., Kaminska M.E. Ductility and Failure Mode of RC Beams Strengthened for Flexure with CFRP. Department of Concrete Structures, Technical University of Lodz; Lodz, Poland: 2003. Report No. 13. [Google Scholar]
  • 33.Tumialan G., Serra P., Nanni A., Belarbi A. Concrete Cover Delamination in RC Beams Strengthened with FRP Sheets. SP-188; Proceedings of the 4th International Symposium on FRP for Reinforcement of Concrete Structures (FRPRCS4); Baltimore, MD, USA. 31 October–5 November 1999; Farmington Hills, MI, USA: American Concrete Institute; 1999. pp. 725–735. [Google Scholar]
  • 34.Siddiqui N.A. Experimental investigation of RC beams strengthened with externally bonded FRP composites. Lat. Am. J. Solids Struct. 2009;6:343–362. [Google Scholar]
  • 35.Yeong-Soo S., Chadon L. Flexural Behavior of Reinforced Concrete Beams Strengthened with Carbon Fiber-Reinforced Polymer Laminates at Different Levels of Sustaining Load. ACI Struct. J. 2003;100:231–239. [Google Scholar]
  • 36.Bonacci J.F., Maalej M. Externally Bonded Fiber-Reinforced Polymer for Rehabilitation of Corrosion Damaged Concrete Beams. ACI Struct. J. 2000;97:703–711. [Google Scholar]
  • 37.Mazzotti C., Savoia M. Experimental Tests on Intermediate Crack Debonding Failure in FRP—Strengthened RC Beams. Adv. Struct. Eng. 2009;12:701–713. doi: 10.1260/136943309789867827. [DOI] [Google Scholar]
  • 38.Maalej M., Leong K.S. Effect of beam size and FRP thickness on interfacial shear stress concentration and failure mode of FRP-strengthened beams. Compos. Sci. Technol. 2005;65:1148–1158. doi: 10.1016/j.compscitech.2004.11.010. [DOI] [Google Scholar]
  • 39.Mostafa A., Razaqpur G.A. CFRP Anchor for Preventing Premature Debonding of Externally Bonded FRP Laminates from Concrete. J. Compos. Constr. 2013;17:641–650. doi: 10.1061/(ASCE)CC.1943-5614.0000377. [DOI] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Data Availability Statement

Not applicable.


Articles from Materials are provided here courtesy of Multidisciplinary Digital Publishing Institute (MDPI)

RESOURCES