Skip to main content
International Dental Journal logoLink to International Dental Journal
. 2022 Aug 26;72(6):859–865. doi: 10.1016/j.identj.2022.06.016

Evaluating the Mechanical Properties of Restorative Glass Ionomers Cements

Sarah Bahammam a,b,, Dan Nathanson b, Yuwei Fan b
PMCID: PMC9676557  PMID: 36031428

Abstract

Objective

The aim of this research was to assess the efficiency of 4 restorative glass ionomer cements (GICs): Fuji IX (GC), ChemFil Rock (DENSPLY), Riva Self-Cure (SDI), and Ketac Nano (3M ESPE).

Materials and methods

The 4 restorative glass ionomers’ diametral tensile and compressive strengths were evaluated at room temperature for 24 hours and then stored in distilled water. The universal testing machine (INSTRON 5566A) was used to record the maximum load necessary to fracture specimens. Surface wear, diametral tensile strength, and compressive strength against dental ceramic were compared using analysis of variance followed by the Bonferroni method at a significance level of 0.05.

Results

Ketac Nano and ChemFil Rock were found to have better diametral tensile strength than Riva Self-Cure and Fuji IX. The significant difference between ChemFil Rock and Fuji IX (P ≤ .005) and ChemFil Rock with Riva Self-Cure (P ≤ .005) was shown by post hoc analysis. Ketac Nano had better tensile strength than Riva Self-Cure and Fuji IX. Fuji IX showed the lowest material loss of the GICs as revealed by wear against VITABLOCS Mark II (VITA Zahnfabrik).

Conclusions

This study indicated a significant difference in the compressive strengths of ChemFil Rock and Riva Self-Cure. ChemFil Rock had the highest tensile strength. The diameter tensile strength of all 4 materials was statistically insignificant. Finally, Fuji IX had the least amount of material loss. ChemFil Rock was proven to be more effective than Fuji IX.

Key words: Compressive strength, Glass ionomer cement, Mechanical properties, Restoration, Retention power

Introduction

Recent advancement in dentistry compels the dominating use of dental restorative materials in the market. Ceramic and gold as indirect restorative materials are common, whilst amalgam has been utilised in direct restorations.1 Amalgam use has been restricted due to allergy and toxic reactions.2 A variety substitutes (resin composites and glass ionomer cements [GICs]) have evolved as a result of significant advances in dental research.3 The most aesthetically pleasing materials with acceptable physical qualities are resin composites.4 They have disadvantages in that they are a very costly, time-consuming, and technique-dependent adhesive treatment.5 Biocompatibility, chemical union to mineralised tissue, and continual fluoride release are only a few of the benefits of using these materials.6 Inferior mechanical qualities, such as reduced fracture strength, toughness, and wear, preclude their usage in dentistry.7,8 GICs are often used as a material for temporary fillings in the posterior dental area.9

These characteristics are especially significant when using orthodontic bands to prevent the occurrence of caries and periodontal disorders whilst also providing enough union strength between teeth and bands.10,11 The study by Jayanthi and Vinod12 investigated flexural strength and compressive strength. However, no previous study has collectively evaluated diametral tensile strength, compressive strength, material loss, and wear resistance. The cost of GICs is considered in the majority of public and private health care setups by health care professionals, and it influences the selection of GICs. Investigating the compressive strength of ionomers is imperative, as it helps in understanding the mechanical integrity of a specific material. The present study aimed to compare the mechanical characteristics of 4 restorative GICs: ChemFil Rock (DENSPLY), Fuji IX (GC), Ketac Nano (3M ESPE), and Riva Self-Cure (SDI).

Materials and methods

Specimen synthesis

ChemFil Rock, Fuji IX, Ketac Nano, and Riva Self-Cure were the 4 restorative glass ionomers tested in this study, which used an in vitro experimental study design. These materials’ diametral tensile and compressive strengths were evaluated at room temperature for 24 hours and then stored in distilled water. In a Teflon mould with a 6-mm depth, glass ionomer specimens measuring 6 mm in diameter and 3 mm in height were created. After that, the components were sandwiched between 2 tiny glass slides. A single operator followed the manufacturer's instructions for the synthesis of specimens. A digital calliper was used to assess the accuracy of specimens before beginning the experimental method. All of the specimens were light cured using Coltolux 75 (Coltène/Whaledent). After polymerisation, the research samples were kept at 100% relative humidity. During cross-sectioning on silicon carbide sheets, wet grinding (Mecapol P 251, PRESI) was performed, followed by slurry polishing. All study specimens were ultrasonically cleaned through Axtor CD–4820 after placing them for 15 minutes in distilled water, before further continuing the procedure.

Mechanical testing and microstructure analyses

The compressive and diametral tensile strengths of materials were calculated. The universal testing machine (INSTRON 5566A) was used to record the maximum load necessary to fracture specimens (Figure 1). For each of the GICs, 20 specimens were prepared for a duration of 1 hour to determine diametral tensile strength (DTS), compressive strength (CS), and wear time. The CS calculation was done using the equation CS = 4Pd2, where P = maximum applied force a at fracture and d = specimen diameter.13 The DTS was determined from the relationship DTS = 2P/πDT, where P is load at fracture and D = diameter and T = specimens thickness.14 In the compressive strength test, specimens were loaded with flat ends between the platens of the apparatus; consequently, the load may be applied to the long axis at a crosshead speed of 0.5 mm/min, which is the same as the crosshead speed employed by Bhattacharya et al15 and Sulaiman et al.16 For diametral tensile strength testing, the specimens were placed with flat ends perpendicular to the platens of the apparatus, and the load was applied to the diameter of the specimens at a crosshead speed of 0.5 mm/min. The Leica Application Suite software (Leica Microsystems) was used to link the microscope to the computer, and the black-and-white pictures were analysed using Adobe Photoshop (Adobe Systems Software).

Fig. 1.

Fig 1

Universal testing machine (INSTRON 5566A).

Wear tests

The specimens were kept in distilled water for 24 hours before commencing the wear testing. In vitro wear against VITABLOCS Mark II (VITA Zahnfabrik) was measured using the standard flat pin-on-plate method. In this 2-body abrasion test, no abrasive substance was employed. The experiment was set up by inserting the plates in a rectangular mould with dimensions of 10 mm long, 3 mm wide, and 2 mm deep. The materials to be tested were put into the mould and allowed to cure for the necessary amount of time before being immersed in water for 100,000 abrasive cycles (30 cycles/min) of linear wear. VITABLOCS Mark II was used to make antagonist pins with a diameter of 2.6 mm. With a lateral movement of 5 mm powered by a rotary motor, consistent contact between opposing pins and the testing material surface was maintained at a weight of 90 gm. Using an optical profilometer, the depth of the groove generated in micrometres (m) was measured (Mahr Perthen). Selected glass ionomer specimens were examined using a scanning electron microscope with a backscattering electron detector to perform a comparison between the abrasion part and the undamaged section. The specimens were sputter-coated with palladium and gold using a sputter coater (Hummer II Technics) (25% Pd/75% Au). The wear of the glass ionomer surface induced by the ceramic VITABLOCS Mark II cylinders was examined using a depth micro analyser.

Data collection and analysis

Surface wear, diametral tensile strength, and compressive strength against dental ceramic were compared using analysis of variance followed by the Bonferroni method at a significance level of 0.05. When numerous pairwise evaluations are performed with a single data set,17 the Bonferroni method is used to compute the correlation, which is utilised to reduce the appearance of false-positive results and detect significant differences in the materials in each group.

Results

The wear resistance, compressive strength, and diametral tensile strength of the 4 restorative glass ionomers were investigated. Chemical composition of glass ionomers is shown in Table 1. Figure 1 shows the mean material loss, diametral tensile strength, and compressive strength. ChemFil Rock (171.3 ± 30.99 MPa) was found to have highest mean compressive strength followed by Fuji IX (131.2 ± 10.03 MPa) and Ketac Nano (118.2 ± 16.45 MPa). ChemFil Rock (19.1 ± 3.44 MPa) was found to have better diametral tensile strength than Riva Self-Cure (14.2 ± 5.47 MPa) and Fuji IX (14.1 ± 2.13 MPa). The significant difference between ChemFil Rock and Fuji IX (P ≤ .05) and ChemFil Rock with Riva Self-Cure (P ≤ .05) was shown by post hoc analysis. Ketac Nano had better tensile strength (18.8 ± 4.10 MPa) than Riva Self-Cure (14.2 ± 5.47 MPa, P ≤ .05) and Fuji IX (14.1 ± 2.13 MPa, P ≤ .05). Fuji IX showed the lowest material loss (0.03 ± 0.006 MPa; Table 2). When compared to the fillers in the intact area, the fillers in the abrasion area were more defined, with sharp edges. Furthermore, in the abrasion area, the fillers were more exposed to the surface. The fillers were primarily embedded in the intact area for resin-modified glass ionomers, resulting in a polymer-rich unpolished glass ionomer surface (Fig. 2, Fig. 3, Fig. 4, Fig. 5, Fig. 6, Fig. 7).

Table 1.

Chemical composition of glass ionomers.

Materials Composition Manufacturer
ChemFil Rock (Dentsply) Polyacrylic and tartaric acid, fluorosilicate, and BHT VOCO AC, Guxhaven, Germany
Fuji IX (GC) Fluoroaluminosilicate glass, multifunctional methacrylate, water, methylmethacrylate, polyacrylic acid, camphorquin GC Corp, Tokyo, Japan
Ketac Nano(3M ESPE) Al-Ca-La fluorosilicate glass, ethanediyl ester, copolymer acrylic, maleic acid, and aminoethyl ester dicyclopentyldimethylene diacrylate 3M ESPE AG, Seefeld, Germany
Riva Self-Cure (SDI) Fluoroaluminosilicate glass, acrylic monomer, and polyacrylic acid + tartaric acid SDI, Victoria, Australia

Table 2.

Post hoc analysis for the comparison of difference in mean diametral tensile strength, compressive strength, and material loss of GICs.

GIC Comparison GIC Compressive strength P value Diametral tensile strength P value Wear against dental ceramic P value
ChemFil Rock Fuji IX >.05 <.05 <.05
Ketac Nano <.05 >.05 <.05
Riva Self-Cure <.05 <.05 <.05
Fuji IX Ketac Nano >.05 <.05 <.05
Riva Self-Cure <.05 >.05 <.05
Ketac Nano Riva Self-Cure <.05 <.05 <.05

GIC, glass ionomer cement.

Fig. 2.

Fig 2

Mean diametral tensile strength, compressive strength, and material loss of glass ionomer cements.

Fig. 3.

Fig 3

ChemFil Rock (intact area) at a 1000× magnification.

Fig. 4.

Fig 4

ChemFil Rock (abrasion area) at 1000× magnification.

Fig. 5.

Fig 5

Riva Self-Cure: A, intact; B, abrasion area at 1000× magnification.

Fig. 6.

Fig 6

Fuji IX: A, intact; B, abrasion area at 1000× magnification.

Fig. 7.

Fig 7

Ketac Nano: A, intact; B, abrasion area at 1000× magnification.

Discussion

The goal of this in vitro study was to examine the efficiency of 4 different restoration glass ionomers in terms of diametral tensile strength, compressive strength, and material loss. Ketac Nano and ChemFil Rock had greater tensile strength than the others. The tensile strengths of Riva Self-Cure and Fuji IX are statistically different at 14.2 ±5 .47 MPa and 14.1 ± 2.13 MPa, respectively. These results are comparable to those of a study by Pilo et al,18 who found the same shear punch strength of glass ionomer cement when coated with varnishes. It was also proposed that the glass ionomer surface's strength may be improved by coating it to prevent it against water-based contamination. ChemFil Rock may be used to include fillers since it produces incremental itaconic acid, which boosts the glass ionomer's resistance capabilities.19 The diametral strength of ChemFil Rock and Ketac Nano was higher than that of Fuji IX. Khairina et al20 made an interesting point, claiming that the diametral tensile strength of bulk-fill composite resin increases as the storage temperature rises. The approach used in this study allowed for a comparison of varied behaviours of restorative materials, as material loss in all of the materials studied ranged from 0.038 to 0.079 m.

In comparison to the other materials examined, Fuji IX showed the least wear. These findings are consistent with those of Kunzelmann et al,21 who discovered that Fuji IX had the least amount of material loss when compared to Ketac Silver and Ketac Molar. Ryu et al22 looked at the wear resistance of several GICs and found a substantial difference in early wear rates as well as a considerable decrease in long-term wear rates. Within the time frame of 4 months to 1 year, however, evidence of wear reduction was also detected. Wear resistance tests have indicated that different powder particles impact the interfacial interaction between the polymer matrix and the particles.

According to the findings, ChemFil Rock had the highest compressive strength. The compressive strength of Ketac Molar and Fuji IX was estimated and compared to previously published results.23 Research by Zoergiebel et al24 looked at the chemical composition of acrylic liquid and filler in 4 different GICs: Fuji IX Fast (GC), Riva Self-Cure (SDI), ChemFil Rock (Dentsply, York, PA, USA), and Fuji IX GP Extra/Equia (GC). Zinc is a prominent component of ChemFil Rock's glass composition. The unique zinc accretion, which is expected to improve reactivity, and the contribution of zinc oxide as a network modifier to the Si–O–Si bond breakage in the glass,24 which increases the glass's sensitivity to acid attack,25, 26, 27 imply that this GIC has better mechanical characteristics.

The characteristics of GICs are examined for 24 hours or more after mixing, according to the majority of research.18,28 There are certain limitations to the current study. One of the study's significant flaws is that it only employed 4 restorative materials and did not assess the diametral tensile and compressive strength of each material over time. Furthermore, the test only lasted 24 hours, and no additional evaluations were done based on the time interval. A weakness of the study is that it only considers the initial cost; however, long-term cost effectiveness is unclear. Long-term effect should be tested, however, it was not the scope of this study.

Conclusions

This study indicated the significant difference in the compressive strengths of ChemFil Rock and Riva Self-Cure. ChemFil Rock had the highest tensile strength. The diameter tensile strength of all 4 materials was statistically insignificant. Finally, Fuji IX had the least amount of material loss. ChemFil Rock was proven to be more effective than Fuji IX. In view of the findings of this study and their comparison to past research, it is recommended that more research be done on the kinetics of GICs and their relationship to various mechanical characteristics on the first day of mixing.

Conflict of interest

None disclosed.

Acknowledgements

The author acknowledges all the associated personnel, who in any reference contributed in the completion of this study. The lab manager Claire Chang and Dr. Richard Pober were assisting this study.

REFERENCES

  • 1.Friberg LT, Schrauzer GN. Thieme; Stuttgart, Germany: 1995. Status quo and perspectives of amalgam and other dental materials. [Google Scholar]
  • 2.Roulet JF. Benefits and disadvantages of tooth-coloured alternatives to amalgam. J Dent. 1997;25:459–473. doi: 10.1016/s0300-5712(96)00066-8. [DOI] [PubMed] [Google Scholar]
  • 3.Hickel R, Dasch W, Janda R, Tyas M, Anusavice K. New direct restorative materials. Int Dent J. 1998;48:3–16. doi: 10.1111/j.1875-595x.1998.tb00688.x. [DOI] [PubMed] [Google Scholar]
  • 4.Manhart J, Kunzelmann KH, Chen HY, Hickel R. Mechanical properties of new composite restorative materials. J Biomed Mater Res. 2000;53:353–361. doi: 10.1002/1097-4636(2000)53:4<353::aid-jbm9>3.0.co;2-b. [DOI] [PubMed] [Google Scholar]
  • 5.Van Meerbeek B, De Munck J, Yoshida Y, et al. Buonocore memorial lecture. Adhesion to enamel and dentin: current status and future challenges. Oper Dent. 2003;28:215–235. [PubMed] [Google Scholar]
  • 6.Yip HK, Tay FR, Ngo H, Smales RJ, Pashley DH. Bonding of contemporary glass ionomer cements to dentin. Dent Mater. 2001;17:456–470. doi: 10.1016/s0109-5641(01)00007-0. [DOI] [PubMed] [Google Scholar]
  • 7.Xie D, Brantley WA, Culbertson BM, Wang G. Mechanical properties and microstructures of glass-ionomer cements. Dent Mater. 2000;16:129–138. doi: 10.1016/s0109-5641(99)00093-7. [DOI] [PubMed] [Google Scholar]
  • 8.Pelka M, Ebert J, Schneider H, Krämer N, Petschelt A. Comparison of two- and three-body wear of glass-ionomers and composites. Eur J Oral Sci. 1996;104:132–137. doi: 10.1111/j.1600-0722.1996.tb00057.x. [DOI] [PubMed] [Google Scholar]
  • 9.Hickel R, Manhart J, Garcia-Godoy F. Clinical results and new developments of direct posterior restorations. Am J Dent. 2000;13:41–54. [PubMed] [Google Scholar]
  • 10.Weissheimer F, Marchioro EM, Dolci GS, Spohr AM. Novos materiais utilizados na cimentação de bandas ortodônticas. Ortodon Gaúch. 2005:23–28. [Google Scholar]
  • 11.Weissheimer F, Marchioro EM, Dolci GS, Spohr AM, Hahn L. A influência do jateamento na cimentação de bandas ortodônticas. Revista Dental Press de Ortodontia e Ortopedia Facial. 2006;11(3):81–87. [Google Scholar]
  • 12.Jayanthi N, Vinod V. Comparative evaluation of compressive strength and flexural strength of conventional core materials with nanohybrid composite resin core material an in vitro study. J Indian Prosthodont Soc. 2013;13(3):281–289. doi: 10.1007/s13191-012-0236-4. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 13.ISO . International Organization for Standardisation; 2009. Water-based cements-part 1: powder/liquid acid-base cements. ISO 9917-1:2007. [Google Scholar]
  • 14.Wang L, D'Alpino PHP, Lopes LG, Pereira JC Mechanical properties of dental restoratives materials: relative contribution of laboratory tests. J Appl Oral Sci. 2003;11:162–167. doi: 10.1590/s1678-77572003000300002. [DOI] [PubMed] [Google Scholar]
  • 15.Bhattacharya A, Vaidya S, Tomer AK, et al. Evaluation and comparison of physical properties and fluoride release of newly introduced ceramic reinforced glass-ionomer restorative material with other glass ionomer cements–an in vitro study. Int J Appl Dent Sci. 2017;3:486–492. [Google Scholar]
  • 16.Sulaiman TA, Abdulmajeed AA, Altitinchi A, et al. Effect of resin-modified glass ionomer cement dispensing/mixing methods on mechanical properties. Oper Dent. 2018;43(4):E158–E165. doi: 10.2341/17-166-L. [DOI] [PubMed] [Google Scholar]
  • 17.Matthew A, Napierala MD. What is the Bonferroni correction? 2014. Available from:https://pdfs.semanticscholar.org/d981/fdd547036e35d80fa771341c2d71e196dd82.pdf. Accessed 15 August 2002.
  • 18.Pilo R, Ben-Amar A, Barnea A, et al. The effect of resin coating on the shear punch strength of restorative glass ionomer cements. Clin Oral Investig. 2017;21(4):1079–1086. doi: 10.1007/s00784-016-1862-8. [DOI] [PubMed] [Google Scholar]
  • 19.Molina GF, Cabral RJ, Mazzola I, et al. Mechanical performance of encapsulated restorative glass-ionomer cements for use with Atraumatic Restorative Treatment (ART) J Appl Oral Sci. 2013;21:243–249. doi: 10.1590/1679-775720130129. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 20.Khairina N, Puspitasari D, Diana S. The comparison of the storage temperature on diametral tensile strength value of bulk-fill resin composite. Dentino: Jurnal Kedokteran Gigi. 2013;3(1):76–80. [Google Scholar]
  • 21.Kunzelmann KH, Bürkle V, Bauer C. Two-body and three-body wear of glass ionomer cements. Int J Paediatr Dent. 2003;13(6):434–440. doi: 10.1046/j.1365-263x.2003.00499.x. [DOI] [PubMed] [Google Scholar]
  • 22.Ryu W, Park H, Lee J, Seo H. Effect of nano-filled protective coating on microhardness and wear resistance of glass-ionomer cements. JKAPD. 2019;46(2):226–232. [Google Scholar]
  • 23.Algera TJ, Kleverlaan CJ, Prahl-Andersen B, Feilzer AJ. The influence of environmental conditions on the material properties of setting glass-ionomer cements. Dent Mater J. 2006;22(9):852–856. doi: 10.1016/j.dental.2005.11.013. [DOI] [PubMed] [Google Scholar]
  • 24.DENTSPLY Wissenschaftliches Kompendium ChemFil Rock. Available from: https://www.dentsplysirona.com/en-us/shop/R-BP-1000170016/chemfil-rock.html. Accessed 15 August 2022.
  • 25.Darling M, Hill R. Novel polyalkenoate (glass-ionomer) dental cements based on zinc silicate glasses. Biomaterials. 1994;15(4):299–306. doi: 10.1016/0142-9612(94)90055-8. [DOI] [PubMed] [Google Scholar]
  • 26.Boyd D, Towler M, Law R, Hill R. An investigation into the structure and reactivity of calcium-zinc-silicate ionomer glasses using MAS-NMR spectroscopy. J Mat Sci: Mat Med. 2006;17(5):397–402. doi: 10.1007/s10856-006-8465-x. [DOI] [PubMed] [Google Scholar]
  • 27.Boyd D, Towler M. The processing, mechanical properties and bioactivity of zinc based glass ionomer cements. J Mat Sci: Mat Med. 2005;16(9):843–850. doi: 10.1007/s10856-005-3578-1. [DOI] [PubMed] [Google Scholar]
  • 28.Zoergiebel J, Ilie N. An in vitro study on the maturation of conventional glass ionomer cements and their interface to dentin. Acta Biomater. 2013;9(12):9529–9537. doi: 10.1016/j.actbio.2013.08.010. [DOI] [PubMed] [Google Scholar]

Articles from International Dental Journal are provided here courtesy of Elsevier

RESOURCES