Abstract
OBJECTIVE:
The most appropriate ventilatory mode during fiberoptic bronchoscopy is still not yet known clearly for patients with acute respiratory distress syndrome. Airway pressure release ventilation is used as a recovery treatment for patients with severe acute respiratory distress syndrome. In this study, the aim was to evaluate the safety of the fiberoptic bronchoscopy process in patients with severe acute respiratory distress syndrome ventilated with airway pressure release ventilation mode and its effect on gas exchange and respiratory mechanics.
MATERIAL AND METHODS:
Single-center retrospective observational study was performed in the intensive care unit of a tertiary referral center from September 2018 to November 2019. Patients with severe ARDS ventilated with APRV mode and undergoing FB were included. Fiberoptic bronchoscopy was performed by an expert intensivist-pulmonologist. All ventilator parameters set by the clinician were kept stable, and no change was made other than O2 concentration. The mechanical ventilation parameters and arterial blood gas values before and after the procedure and fiberoptic bronchoscopy-related complications were recorded for the first 24 hours.
Results:
A total of 14 acute respiratory distress syndrome patients who were ventilated with airway pressure release ventilation were enrolled. No significant deteriorations were detected in gas exchange, pulmonary compliance, and airway resistance values in our case series. It was observed that a small reduction in PaO2 and an increase in PaCO2 were present after the 1st hour; however, both were returned to baseline values in the 24th hour. Only 1 patient developed fiberoptic bronchoscopy-induced hypoxemia (7.1%). Complications, such as fiberoptic bronchoscopy-induced barotrauma, pneumothorax, hemodynamic deterioration, and bleeding, were not detected.
Conclusion:
According to our preliminary findings, performing fiberoptic bronchoscopy under airway pressure release ventilation mode by an experienced bronchoscopist does not bring additional complication risks in patients with severe acute respiratory distress syndrome.
Keywords: Acute respiratory distress syndrome, airway pressure release ventilation, fiberoptic bronchoscopy, pulmonary mechanics
Main Points
Fiberoptic bronchoscopy (FB) is a technique that is often used both for diagnostic and therapeutic purposes in the intensive care unit.
Acute respiratory distress syndrome (ARDS) is an important clinical manifestation progressing with refractory hypoxemia and can cause multiple organ failure and mortality.
Airway pressure release ventilation (APRV) mode is frequently applied to patients with ARDS and deep hypoxemia.
The most appropriate ventilatory mode during FB is still not yet known clearly for patients with ARDS.
Performing fiberoptic bronchoscopy in APRV mode by an experienced bronchoscopist does not bring additional complication risks.
Introduction
Acute respiratory distress syndrome (ARDS) is an important clinical manifestation progressing with refractory hypoxemia and can cause multiple organ failure and mortality.1 Airway pressure release ventilation (APRV) is used as a novel supportive treatment for acute hypoxemic respiratory failure and in patients with ARDS, especially when conventional mechanical ventilation modes do not provide adequate oxygenation.2 It was shown that using APRV mode in patients with ARDS could affect ventilation/perfusion balance positively by providing alveolar recruitment, improve oxygenation, and result in reduced ventilator need and length of stay in intensive care.3
Fiberoptic bronchoscopy (FB) is a technique that is often used both for diagnostic and therapeutic purposes in the intensive care unit (ICU). The bedside applicability and low complication rates are major advantages. It is well known that severe hypoxemia is an important complication of FB, still, FB may be an indispensable tool for diagnostic purposes in selected ARDS patients with refractory hypoxemia.4 The most appropriate ventilation method during FB is still unknown in this subgroup of patients.
Airway pressure release ventilation mode is frequently applied to patients with ARDS and deep hypoxemia in our center. In this case series study, our purpose was to evaluate the safety of the FB process in patients with severe ARDS who were ventilated in APRV mode and its effect on gas exchange and respiratory mechanics.
Material and Methods
Patients
The study was a case series study. The data were withdrawn from the ICU-FB database, in which the data were collected prospectively since 2017. Patients with severe ARDS who were ventilated in APRV mode between September 2018 and December 2019 and underwent FB were included in the study (Figure 1). This retrospective study was performed in an adult ICU after Dokuz Eylül University ethics committee approval (No:2020/06-29). The informed consent was waived because of the nature of the study.
Figure 1.
Flowchart of study.
Variables
The demographic data of patients, acute physiology and chronic health evaluation (APACHE) II scores, FB indication, previous and ongoing treatments (i.e. vasopressor/sedation) treatment, renal replacement therapy, immunosuppressive treatment) were recorded. All patients were ventilated with Dräger Evita® Infinity® V500.
The mechanical ventilation parameters before sedation application were recorded as tidal volume (VT), fraction of inspired oxygen (FiO2), high airway pressure (Phigh) and the time spent at this pressure (Thigh), low air pressure (Plow) and the time spent at this pressure (Tlow), mean airway pressure (Pmean), and peak airway pressure (Ppeak). Plow was used as 0 cm H2O and Tlow 0.5 seconds in all patients. Pre-sedation pulmonary mechanics (i.e., compliance and resistance), arterial blood gas values for pH, partial pressure of oxygen (PaO2), partial pressure of carbon dioxide (PaCO2), oxygen saturation (SaO2), and ratio of PaO2 to FiO2 were also recorded.
Fiberoptic Bronchoscopy Procedure
Indication of FB
Indication and the decision for FB were primarily determined by consulting intensivist. All procedures were performed by an intensivist-pulmonologist who had expertise >15 years of performing FB in critically ill patients. According to the local ICU FB protocol, severe hemodynamic instability was considered a contraindication to performing FB.
Sedation for FB
The ICU sedation protocol included midazolam and fentanyl infusions for FB procedure. Rocuronium was used as needed for muscle relaxation during the procedure.
Fiberoptic bronchoscopy Procedure
After it was confirmed that the endotracheal tubes (ETT) were at least 8.0 mm in diameter, the bronchoscope (5.9-mm outer-diameter Olympus BF 10 bronchoscope) was placed in the ETT with a special adapter valve. At least 5 min before the procedure, FiO2 was set at 0.9-1.0 and was kept in this setting throughout the procedure. All ventilator parameters set by the consulting intensivist were kept stable, and the inhaled and exhaled tidal volumes and vital findings during the procedure were monitored and recorded closely. The duration of FB and the amount of fluid given and recovered for bronchial lavage and bronchoalveolar lavage (BAL) were noted. Inspired oxygen fraction was decreased gradually to >90% peripheral (pulse) oxygen saturation (SpO2) after FB. After FB procedure, and at 1st and 24th hours, patients’ vital signs (i.e., peak heart rate, blood pressure, and body temperature), arterial blood gas values, mechanical ventilator parameters, pulmonary mechanics, and PaO2/FiO2 values were recorded. Possible complications in the first 24 h after FB, such as FB-related desaturation (SpO2 < 90), hemodynamic deterioration, barotrauma-related complications, such as pneumothorax and/or pneumomediastinum, and bleeding, were recorded.
Statistical Analysis
All categorical variables are expressed as numbers and percentages, and continuous variables were expressed as median and interquartile range (IQR). Categorical variables between groups were compared with chi-square or Fisher’s exact test, and continuous variables were compared with Mann–Whitney U-test. A two-tailed P value of .05 was considered statistically significant. Statistical analysis was performed with Statistical Package for the Social Sciences (Version 22; IBM Corporation, Armonk, NY, USA) program.
Results
A total of 14 patients (10 males, 4 females) with severe ARDS were included in the study. Median (IQR) age was 62.5 (43.5-69.7) years, and median (IQR) APACHE II score was 21 (15.7-26.2). Fiberoptic bronchoscopy indication was mainly for sampling of the respiratory tract in order to evaluate/exclude any respiratory infection in 12 patients (85.7%) and suspicion of interstitial lung disease in 2 patients (14.3%). Eight patients (57.1%) had active immunosuppression. Six patients (42.8%) to exclude any opportunistic infection. Five patients (35.7%) were receiving vasopressor agent (noradrenaline) due to the presence of refractory septic shock while performing FB (Table 1). The duration of FB was 8 (IQR 6-10) minutes. An average of 100 mL (IQR 50-105 mL) saline fluid was given in BAL process, and 50 mL (IQR 30-60 mL) was recovered.
Table 1.
Baseline Characteristics of the Study Patients
Variables | Patients (n = 14) |
---|---|
Age | 63 (40-71) |
Male sex | 10 (71.4) |
APACHE II score | 21 (16-26) |
SOFA1 score | 6 (5-7) |
GCS score | 10 (7-13) |
Main reason for ICU admission | |
Sepsis/septic shock | 5 (35.7) |
Pneumonia | 9 (64.3) |
Comorbidities | |
Hypertension | 6 (42.9) |
Rheumatoid arthritis | 1 (7.1) |
Coronary artery disease | 3 (21.4) |
Diabetes mellitus | 3 (21.4) |
Malignancy | 3 (21.4) |
Chronic renal disease | 1 (7.1) |
Common variable immunodeficiency | 1 (7.1) |
Renal transplantation | 1 (7.1) |
Dermatomyositis | 1 (7.1) |
Liver transplantation | 1 (7.1) |
Indications for FB | |
Respiratory infection | 12 (85.7) |
Suspicion of interstitial lung disease | 2 (14.3) |
Event on FB day | |
Vasopressor need2 | 5 (35.7) |
Hemodialysis | 5 (35.7) |
ICU mortality | 10 (71.4) |
All values are expressed as numbers (percentages) or median (interquartile range).
APACHE, Acute Physiology and Chronic Health Evaluation; FB, fiberoptic bronchoscopy; GCS, Glasgow Coma Scale; ICU, intensive care unit; SOFA, Sequential Organ Failure Assessment.
1SOFA score in the first day
. 2Norepinephrine > 0.15 μg/kg/min.
Gas Exchange
In the arterial blood gas analysis, it was observed that a small reduction in PaO2 and an increase in PaCO2 were present after the 1st hour; however, both were returned to baseline values in the 24th hour (Table 2). Partial pressure of oxygen was below 60 mmHg (57 mmHg and 59 mmHg) in 2 patients at the 1st hour after the procedure and was below 60 mmHg (53 mmHg) in 1 patient at the 24th hour. The changes in SaO2 were similar to those in PaO2. The median value of PaO2/FiO2 rate was below the baseline at the 1st hour after the procedure and was above the basal value at the 24th hour. Clinically nonsignificant changes were observed in pH secondary to PaCO2 levels.
Table 2.
Arterial Blood Gas Values (n = 14)
Baseline (Before FB) | Immediate After the FB Procedure | After the FB Procedure (1st Hour) | After the FB Procedure (24th Hour) | |
---|---|---|---|---|
pH | 7.33 (7.27-7.42) | 7.28 (7.21-7.37) | 7.34 (7.20-7.38) | 7.31 (7.26-7.37) |
PaO2 (mmHg) | 83.0 (68.2-100.5) | 119.5 (85.0-194.2) | 76.5 (68.7-90.5) | 84.0 (73.5-107) |
PaCO2 (mmHg) | 45.5 (40.7-49.0) | 48.5 (46.0-52.0) | 44.5 (41.0-53.5) | 46.5 (37.7-50.2) |
SaO2 (%) | 96.0 (92.5-97.2) | 98.0 (95.7-99.0) | 94.5 (92.0-96.2) | 95.5 (92.0-97.2) |
Data are presented as median and interquartile range (IQR). Abbreviations: FB, fiberoptic bronchoscopy; PaO2, partial pressure of oxygen; PaCo2, partial pressure of carbon dioxide; SaO2, oxygen saturation.
Settings and Lung Mechanics
Although Phigh and Thigh changes were made in line with the changes in oxygenation and ventilation parameters in patients, no changes were detected according to the basal values of the median Phigh and Thigh values after the procedure, and no significant changes were detected in Pmean and Ppeak median values. The median tidal volume remained below the basal value after the procedure, and the values were determined above the basal value at the 1st and 24th hours. There were decreases in the median compliance values just after the procedure, and they were similar to basal values at the 1st and 24th hours. No significant changes were detected in post-procedure resistance values (Table 3).
Table 3.
Mechanical Ventilation Parameters (n = 14)
Baseline (Before FB) | Immediate After the FB Procedure | After the FB Procedure (1st Hour) | After the FB Procedure (24th Hour) | |
---|---|---|---|---|
FiO2 | 0.6 (0.5-0.6) | 1.0 (0.9-1.0) | 0.6 (0.5-0.6) | 0.5 (0.5-0.6) |
Tidal volume (mL) | 530 (477-585) | 519 (443-562) | 562 (457-600) | 541 (450-609) |
PaO2/FiO2 | 142 (119-221) | 130 (88-220) | 134 (118-165) | 154 (132-220) |
Phigh (cm H2O) | 28 (24.7-28.2) | 28 (24.7-28.5) | 28 (25-28.5) | 28 (24.7-28.2) |
Plow (cm H2O) | 0 | 0 | 0 | 0 |
Thigh (seconds) | 4.5 (4.5-5.5) | 4.5 (4.5-5.5) | 4.5 (4.5-5.5) | 4.5 (4.5-5.5) |
Tlow (seconds) | 0.5 | 0.5 | 0.5 | 0.5 |
Pmean (cm H2O) | 25.2 (22.4-25.4) | 25.2 (22-25.2) | 25.2 (22.9-25.6) | 25.2 (22.3-25.7) |
Ppeak (cm H2O) | 28.5 (25-30) | 28.5 (25.7-30.2) | 28.5 (26.0-30.3) | 29.0 (26.0-30.0) |
Compliance (mL/cm H2O) |
29 (23-35) | 27 (21.7-31.2) | 30.5 (22.2-34.7) | 30 (21.5-40.5) |
Resistance (cm H2O/L/s) |
12 (8.7-14.5) | 12 (9.7-14) | 12 (9.7-13.2) | 10.5 (8.7-12.2) |
Data are presented as absolute numbers or as median and interquartile range (IQR). FB, fiberoptic bronchoscopy; FiO2, fraction of inspired oxygen; Phigh, high airway pressure; Thigh, the time spent at high airway pressure; Plow, low air pressure; Tlow, the time spent at low airway pressure; Pmean, mean airway pressure; Ppeak, peak airway pressure.
Complications
The procedure was terminated early only in 1 patient (7.1%) because of desaturation. Hypoxemia (SpO2 < 90%) developed in 1 patient after FB (7.1%), and hypotension developed in 1 patient, which caused an increase in vasopressor requirement within the first 24 h. No new onset arrhythmias were detected. None of the patients developed pneumothorax/pneumomediastinum and bleeding complications in the 24-h follow-ups.
Results of Bronchoalveolar Lavage Specımen
The culture results of BAL revealed Stenotrophomonas maltophilia in 4 patients, Acinetobacter baumannii in 3 patients, Klebsiella pneumoniae in 2 patients, Candida parapsilosis in 1 patient, and Candida albicans in 1 patient. Revision of antibiotic/antimicrobial therapy was made in 7 patients (50%) after FB results.
Intensive Care Unit Mortality
Ten patients died (71.4%). Among 4 who survived, 2 received revised antibiotic/antimicrobial regimen after FB.
Discussion
In the present case series, we have analyzed patients with severe ARDS who have undergone FB procedure with APRV mode. The study has 2 important results. First, FB with APRV mode seemed to be safe with no major complications. Second, although these patients were very fragile and considered to be prone to desaturations with FB, it was observed that pulmonary gas exchange and respiratory mechanics did not change.
In the present study, FB-related hypoxemia is 7.1% in patients with severe ARDS. FB in severely hypoxemic patients under high FiO2 support and/or high PEEP is considered as a relatively high-risk procedure and must be avoided as much as possible.4 Fiberoptic bronchoscopy-related gas exchange abnormalities may occur in almost all critical patients at different degrees. Patients with ARDS may have increased complication risks during FB and BAL because of insufficient oxygenation and unstable hemodynamics.5 Prebil et al6 evaluated the side effects of FB and BAL procedures in 100 patients who were followed up in intubation mechanical ventilator because of ARDS or severe sepsis. Clinically significant hypoxemia (SaO2 < 90%) was detected in 6% of the patients, and early termination of the procedure was required in 1 patient. High PEEP requirement was associated with increased complication rates. This is similar to the results of Schnabel et al. hypoxemia (SaO2 < 88%) with FB was detected in 9% of the patients in patients with mechanical ventilator support, and the mean PaO2/FiO2 values after the 24th hour were similar to the baseline values.7 Although transient hypoxemia was reported in FB patients with deep hypoxemia and high PEEP requirement, we have found that no significant deteriorations were observed in gas exchange within the 24 h. Median PaO2 and SaO2 were detected to be higher than the basal values after the procedure, which may be explained by the increase in FiO2 during the process and perhaps with the correction of atelectatic segments by aspiration of airway secretions.
In our center, we prefer using APRV mode to obtain higher mean air pressures in patients with severe ARDS who require high PEEP support. The purpose of APRV use is to increase oxygenation by providing recruitment with auto-PEEP effect. Theoretically, when the bronchoscope is advanced from ETT, it causes a significant increase in airway pressures in this patient group. Peak inspiratory pressure and intrinsic PEEP increase and might cause significant decreases in ventilation per minute,8,9 which in turn may cause an increased risk of barotrauma pneumothorax and hemodynamic deterioration. However, in our study group, none of these complications was observed. We think that the key factor for this was the expertise of the bronchoscopist as the median duration of FB was relatively short.
Another important factor in patients withn ARDS is performing the BAL procedure. Bronchoalveolar lavage can cause decreased lung compliance and increased airway resistance. The mechanism of changes in compliance and resistance is the direct effect of lavage fluid, the development of inflammatory pulmonary edema, surfactant inactivation, and related atelectasis development.10 In a previous study, pulmonary compliance decreased from 43.3 to 33 mL/cm H2O, and pulmonary resistance increased from 15.16 to 17.54 cm H2O/L/s in measurements after BAL. Both parameters returned to similar values as before the procedure 90 minutes after application. Postoperative decrease severity was higher in patients who had higher compliance before the procedure.11 No significant changes were detected in our study in lung compliance and airway resistance of patients after FB and BAL. This might be due to performing BAL with lower amount of fluid (median fluid amount 100 mL), the return of approximately half of the fluid, and the cleaning of the airways as much as possible while finishing the procedure. Decreased surfactant function and lower compliance may be another reason why our study found no changes in lung compliance as a response to BAL in patients with ARDS.10
Hypertension, hypotension, and electrocardiographic changes may occur during FB.4,8 Since arrhythmia is frequently related to oxygen desaturation, an increase may be expected in cardiovascular complication risks in critical patients. In our study, no hemodynamic deterioration that would require the discontinuation of the procedure occurred during FB; however, 1 patient developed severe hypotension after the procedure, which required an increase in vasopressor support in the first 24 h. We think that this may not be attributable only to the FB procedure itself as about one-third of the patients were receiving vasopressor treatment.
There are several important limitations of this study. First, the study was performed in a single reference ICU; therefore, the results are not generalizable. Second, FB is performed by an experienced bronchoscopist, which may be an important factor for low complication rates. Third, we have included only 14 cases with severe ARDS. Also, we did not compare the APRV mode with other modes, such as the assist control ventilation mode in the present study. Thus, the contribution of APRV mode that improves respiratory mechanics after the FB procedure has a low quality of evidence. On the other hand, we believe that our study has some important strengths. Airway pressure release ventilation mode is a relatively novel approach in severe ARDS, and this is the first study evaluating the safety of APRV mode during the FB procedure. Another important strength was close monitoring of the occurrence of possible complications after FB.
Conclusion
The most appropriate ventilation strategy for FB has not yet been clarified in critically ill patients with severe ARDS. Airway pressure release ventilation is a novel ventilation mode and is being increasingly used for improving oxygenation in severe ARDS. According to our preliminary findings, performing FB in APRV mode by an experienced bronchoscopist does not bring additional complication risks. The optimal ventilatory strategy during FB merits further research.
Footnotes
Ethics Committee Approval: This study was approved by Ethics committee of Dokuz Eylül University, (No:2020/06-29).
Informed Consent: Informed consent was waived because of the nature of the study.
Peer-review: Externally peer-reviewed.
Author Contributions: Concept – M.C.Ö., B.E.; Design – M.C.Ö., M.K.; Supervision – B.C., A.N.G.; Data Collection and/or Processing – M.C.Ö., M.K., Y.L.U.; Analysis and/or Interpretion – B.E., A.N.G.; Litetature Review – M.C.Ö., M.K., B.E.; Writing – M.C.Ö., B.E.; Critical Review – M.C.Ö., B.E., B.C., A.N.G.
Declaration of Interests: The authors have no conflict of interest to declare.
Funding: The authors declared that this study has received no financial support.
References
- 1. ARDS Definition Task Force, Ranieri VM, Rubenfeld GD.et al. Acute respiratory distress syndrome: the Berlin definition. JAMA. 2012;307(23):2526 2533. 10.1001/jama.2012.5669) [DOI] [PubMed] [Google Scholar]
- 2. Mallory P, Cheifetz I. A comprehensive review of the use and understanding of airway pressure release ventilation. Expert Rev Respir Med. 2020;14(3):307 315. 10.1080/17476348.2020.1708719) [DOI] [PubMed] [Google Scholar]
- 3. Zhou Y, Jin X, Lv Y.et al. Early application of airway pressure release ventilation may reduce the duration of mechanical ventilation in acute respiratory distress syndrome. Intensive Care Med. 2017;43(11):1648 1659. 10.1007/s00134-017-4912-z) [DOI] [PMC free article] [PubMed] [Google Scholar]
- 4. Ergan B, Nava S. The use of bronchoscopy in critically ill patients: considerations and complications. Expert Rev Respir Med. 2018;12(8):651 663. 10.1080/17476348.2018.1494576) [DOI] [PubMed] [Google Scholar]
- 5. Steinberg KP, Mitchell DR, Maunder RJ, Milberg JA, Whitcomb ME, Hudson LD. Safety of bronchoalveolar lavage in patients with adult respiratory distress syndrome. Am Rev Respir Dis. 1993;148(3):556 561. 10.1164/ajrccm/148.3.556) [DOI] [PubMed] [Google Scholar]
- 6. Prebil SEW, Andrews J, Cribbs SK, Martin GS, Esper A. Safety of research bronchoscopy in critically ill patients. J Crit Care. 2014;29(6):961 964. 10.1016/j.jcrc.2014.06.006) [DOI] [PMC free article] [PubMed] [Google Scholar]
- 7. Schnabel RM, van der Velden K, Osinski A, Rohde G, Roekaerts PM, Bergmans DC. Clinical course and complications following diagnostic bronchoalveolar lavage in critically ill mechanically ventilated patients. BMC Pulm Med. 2015;15:107. 10.1186/s12890-015-0104-1) [DOI] [PMC free article] [PubMed] [Google Scholar]
- 8. Sadoughi A, Chen A. Bronchoscopy in the Intensive Care Unit. In: Wang K. P., Mehta A. C., Turner J.F.eds. Flexible bronchoscopy (Fourth ed. pp. 411 42 1). Hoboken, NJ: : John Wiley & Sons; 2020. [Google Scholar]
- 9. Nay MA, Mankikian J, Auvet A, Dequin PF, Guillon A. The effect of fibreoptic bronchoscopy in acute respiratory distress syndrome: experimental evidence from a lung model. Anaesthesia. 2016;71(2):185 191. 10.1111/anae.13274) [DOI] [PubMed] [Google Scholar]
- 10. Klein U, Karzai W, Zimmermann P.et al. Changes in pulmonary mechanics after fiberoptic bronchoalveolar lavage in mechanically ventilated patients. Intensive Care Med. 1998;24(12):1289 1293. 10.1007/s001340050764) [DOI] [PubMed] [Google Scholar]
- 11. Estella A. Effects on respiratory mechanics of bronchoalveolar lavage in mechanically ventilated patients. J Bronchology Interv Pulmonol. 2010;17(3):228 231. 10.1097/LBR.0b013e3181e846ee) [DOI] [PubMed] [Google Scholar]