Abstract
Fluorine-19 MRI shows great promise for a wide range of applications including renal imaging, yet the typically low signal-to-noise ratios and sparse signal distribution necessitate a thorough data preparation.This chapter describes a general data preparation workflow for fluorine MRI experiments. The main processing steps are: (1) estimation of noise level, (2) correction of noise-induced bias and (3) background subtraction. The protocol is supplemented by an example script and toolbox available online.This chapter is based upon work from the COST Action PARENCHIMA, a community-driven network funded by the European Cooperation in Science and Technology (COST) program of the European Union, which aims to improve the reproducibility and standardization of renal MRI biomarkers. This analysis protocol chapter is complemented by two separate chapters describing the basic concept and experimental procedure.
Full text of this article can be found in Bookshelf.
References
- Ruiz-Cabello J, Barnett BP, Bottomley PA, Bulte JW (2011) Fluorine (19F) MRS and MRI in biomedicine. NMR Biomed 24(2):114–129 doi: 10.1002/nbm.1570. [DOI] [PMC free article] [PubMed]
- Ahrens ET, Helfer BM, O'Hanlon CF, Schirda C (2014) Clinical cell therapy imaging using a perfluorocarbon tracer and fluorine-19 MRI. Magn Reson Med 72(6):1696–1701 doi: 10.1002/mrm.25454. [DOI] [PMC free article] [PubMed]
- Prinz C, Delgado PR, Eigentler TW, Starke L, Niendorf T, Waiczies S (2019) Toward (19)F magnetic resonance thermometry: spin-lattice and spin-spin-relaxation times and temperature dependence of fluorinated drugs at 9.4 T. Magma 32(1):51–61 doi: 10.1007/s10334-018-0722-8. [DOI] [PubMed]
- Waiczies S, Rosenberg JT, Kuehne A et al (2019) Fluorine-19 MRI at 21.1 T: enhanced spin-lattice relaxation of perfluoro-15-crown-5-ether and sensitivity as demonstrated in ex vivo murine neuroinflammation. Magma 32(1):37–49 doi: 10.1007/s10334-018-0710-z. [DOI] [PMC free article] [PubMed]
- Kuethe DO, Caprihan A, Fukushima E, Waggoner RA (1998) Imaging lungs using inert fluorinated gases. Magn Reson Med 39(1):85–88 doi: 10.1002/mrm.1910390114. [DOI] [PubMed]
- Hu LZ, Chen JJ, Yang XX et al (2014) Assessing intrarenal nonperfusion and vascular leakage in acute kidney injury with multinuclear H-1/F-19 MRI and perfluorocarbon nanoparticles. Magn Reson Med 71(6):2186–2196 doi: 10.1002/mrm.24851. [DOI] [PMC free article] [PubMed]
- Hitchens TK, Ye Q, Eytan DF, Janjic JM, Ahrens ET, Ho C (2011) 19F MRI detection of acute allograft rejection with in vivo perfluorocarbon labeling of immune cells. Magn Reson Med 65(4):1144–1153 doi: 10.1002/mrm.22702. [DOI] [PMC free article] [PubMed]
- Moore JK, Chen J, Pan H, Gaut JP, Jain S, Wickline SA (2018) Quantification of vascular damage in acute kidney injury with fluorine magnetic resonance imaging and spectroscopy. Magn Reson Med 79(6):3144–3153 doi: 10.1002/mrm.26985. [DOI] [PMC free article] [PubMed]
- Henkelman RM (1985) Measurement of signal intensities in the presence of noise in MR images. Med Phys 12(2):232–233 doi: 10.1118/1.595711. [DOI] [PubMed]
- Gudbjartsson H, Patz S (1995) The Rician distribution of noisy MRI data. Magn Reson Med 34(6):910–914 doi: 10.1002/mrm.1910340618. [DOI] [PMC free article] [PubMed]
- van Heeswijk RB, Pilloud Y, Flögel U, Schwitter J, Stuber M (2012) Fluorine-19 magnetic resonance angiography of the mouse. PLoS One 7(7):e42236 doi: 10.1371/journal.pone.0042236. [DOI] [PMC free article] [PubMed]
- Starke L, Pohlmann A, Prinz C, Niendorf T, Waiczies S (2019) Performance of compressed sensing for fluorine-19 magnetic resonance imaging at low signal-to-noise ratio conditions. Magn Reson Med 84(2):592–608 doi: 10.1002/mrm.28135. [DOI] [PubMed]
- National Electrical Manufacturers Association (2001) Determination of signal-to-noise ratio (SNR) in diagnostic magnetic resonance imaging. NEMA standards publication MS 1-2001. NEMA, Arlington, VA
- Koay CG, Basser PJ (2006) Analytically exact correction scheme for signal extraction from noisy magnitude MR signals. J Magn Reson 179(2):317–322 doi: 10.1016/j.jmr.2006.01.016. [DOI] [PubMed]
- Ahn S, Fessler A (2003) Standard errors of mean, variance, and standard deviation estimators. EECS Department, The University of Michigan, Ann Arbor, MI. http://web.eecs.umich.edu/fessler/papers/files/tr/stderr.pdf
- Constantinides CD, Atalar E, McVeigh ER (1997) Signal-to-noise measurements in magnitude images from NMR phased arrays. Magn Reson Med 38(5):852–857 doi: 10.1002/mrm.1910380524. [DOI] [PMC free article] [PubMed]
- Aja-Fernández S, Vegas-Sánchez-Ferrero G (2016) Statistical analysis of noise in MRI. Springer International Publishing, Cham
- Ku HH (1966) Notes on the use of propagation of error formulas. J Res Natl Bur Stand 70(4):263–273