The work of Deng et al. [1, 2] is in many aspects a very remarkable and outstanding study. Without a doubt, it makes a very important contribution to, among other things, the issue of electric current and electrode position in ECT.
My intention in writing this letter to the editor is not so much as a psychiatrist, but more as a physicist, to point out a fundamental problem in the calculation of electric field strength distributions in the human brain. The modeling of the electric field strength distribution in this study was done according to a method that was used in a tDCS study [3]. This immediately points out an important problem, namely that the modeling was done with the basic assumption of a direct current application. This basic assumption is more than doubtful in several respects.
It is historically evident that ECT is an alternating current method, since sinusoidal wave generators were initially used. The sine waves were replaced by the modern short-pulse technology, but the frequencies used remained in the same spectrum. With an alternating current, however, it is not the electrical resistance that is crucial for Ohm’s law, as with a direct current, but the electrical impedance. However, the electrical impedance is not only determined by the electrical resistance, but also by inductivity and capacity of the current-carrying medium. These two parameters (capacity might be more important than inductivity), which are necessary for a correct modeling of the electric field, were not considered in the study. In addition, the portion of the electrical impedance determined by inductivity and capacity is strictly frequency dependent. In ECT, however, frequency typically differs depending on the applied charge (“dose”). This aspect is also not addressed in the study. Another very critical aspect is that the cited methodology study [3] uses current strengths of 1 mA for its calculations, as it is appropriate for tDCS. Currents used in ECT are 2–3 orders of magnitude higher, specifically 600–800 mA in this case. It is a well-known phenomenon in physics that much lower impedances are measured at higher currents (a so called “electrical breakdown” of impedance) [4]. Indeed this effect can also be observed with each individual ECT, because the so-called “static” impedance, which is measured before the stimulus current application, typically lies around 1000–2000 ohms, whereas during the current application the impedance is typically between 200 and 250 ohms. This effect, which would result in lower E-field strength (implicating that deeper brain structures would be less affected) is also not taken into account within the model. Strictly speaking, it must be noted that all these effects (inductivity and capacity, frequency dependence, and impedance dependence with current strength, and maybe even the waveform itself (e.g. sine wave vs. short rectangular pulses)) would have to be known as accurately as possible for each individual voxel of the brain to enable correct finite element modeling. Moreover, it is highly likely that strong direction-dependent effects, for example within the white matter tracts, play an additional role in the final modeling of the electric field [4, 5].
In summary, I would like to point out that the models for calculating the electric field distribution in the human brain should currently be interpreted with care, taking into account that they are not validated by direct measurements. In this regard, it would be desirable to first model electric field distributions in animals and then validate them by direct electric field measurements before implicating consequences for therapeutic decisions of ECT practitioners.
Acknowledgments
Funding
This work was supported by the BMBF (01EW2010B NeuroMarKet) in the frame of ERA-Net NEURON to AS, by the BMWi (ZF4845401BA9 + ZF4070803BA), as well as by the grant DFG SA 1869/15-1 from the German Research Foundation (Deutsche Forschungsgemeinschaft). The BMBF/BMWi/DFG had no further role in the writing of the report and in the decision to submit the paper for publication. Open Access funding enabled and organized by Projekt DEAL.
Competing interests
The author declares no competing interests.
Footnotes
Publisher’s note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
References
- 1.Deng ZD, Argyelan M, Miller J, Quinn DK, Lloyd M, Jones TR, et al. Electroconvulsive therapy, electric field, neuroplasticity, and clinical outcomes. Mol Psychiatry. 2021. Online ahead of print. [DOI] [PMC free article] [PubMed]
- 2.Abbott CC, Quinn D, Miller J, Ye E, Iqbal S, Lloyd M, et al. Electroconvulsive Therapy Pulse Amplitude and Clinical Outcomes. Am J Geriatr Psychiatry. 2021;29:166–78. doi: 10.1016/j.jagp.2020.06.008. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 3.Saturnino GB, Antunes A, Thielscher A. On the importance of electrode parameters for shaping electric field patterns generated by tDCS. NeuroImage. 2015;120:25–35. doi: 10.1016/j.neuroimage.2015.06.067. [DOI] [PubMed] [Google Scholar]
- 4.Unal G, Swami JK, Canela C, Cohen SL, Khadka N, FallahRad M, et al. Adaptive current-flow models of ECT: Explaining individual static impedance, dynamic impedance, and brain current density. Brain Stimul. 2021;14:1154–68. doi: 10.1016/j.brs.2021.07.012. [DOI] [PubMed] [Google Scholar]
- 5.Lee WH, Deng ZD, Kim TS, Laine AF, Lisanby SH, Peterchev AV. Regional electric field induced by electroconvulsive therapy in a realistic finite element head model: influence of white matter anisotropic conductivity. Neuroimage. 2012;59:2110–23. doi: 10.1016/j.neuroimage.2011.10.029. [DOI] [PMC free article] [PubMed] [Google Scholar]