Skip to main content
Scientific Reports logoLink to Scientific Reports
. 2022 Nov 30;12:20655. doi: 10.1038/s41598-022-25190-6

Rapid identification of Staphylococcus aureus based on a fluorescence imaging/detection platform that combines loop mediated isothermal amplification assay and the smartphone-based system

Patricia Cabrales-Arellano 1, Edward Park 2, Martha Minor 1, Efren Delgado 1, Delia Valles-Rosales 3, Heidi Taboada 4, José Espiritu 4, Jianzhong Su 5, Young Ho Park 6,
PMCID: PMC9712598  PMID: 36450878

Abstract

Food associated diseases pose significant public health threat in the United States. Health risks associated with food-borne pathogens drive the need for constant monitoring of food products. An efficient method that can diagnose food-borne pathogens rapidly will be invaluable and in high demand. In this study, we showed the feasibility of a novel rapid detection platform based on fluorescence imaging/detection that combines a user-friendly, portable loop mediated isothermal amplification (LAMP) reaction device and a smartphone-based detection system. The proposed platform was used to detect Staphylococcus aureus which is one of the most important food-borne pathogen especially dairy products. The complete protocol is quicker; the reaction is performed under isothermal conditions and completed in 1 h or less. Experimental results show that LAMP assays were ten-fold more sensitive than PCR-based detection. The proposed smartphone detection system was able to detect and quantify LAMP assay samples containing three different concentrations of S. aureus from 109 CFU/mL down to 103 CFU/mL. The present proof-of-concept study demonstrated that this platform offers a portable, easy to use method for measuring target pathogens with LAMP amplification.

Subject terms: Assay systems, Biological fluorescence

Introduction

Food-borne pathogens are defined as biological agents that cause food-borne illness; they can be either viruses, bacteria and eukaryotes like funguses, protozoa or helminths1. Every year, the Food and Drug Administration (FDA) reports the outbreaks associated with food-borne pathogens; for instance, in 2020, it reported the contamination of Escherichia coli, Listeria monocytogenes and Cyclospora in clover sprouts, Enoki mushrooms and bagged salad, respectively (FDA 2020). Health risks associated with food-borne pathogens drive the need for constant monitoring of food products. For microbial pathogen detection, the conventional method is bacterial growth on a culture medium then on selective agar; it sometimes involves biochemical or serological testing. This process has some disadvantages because it is time consuming, laborious and detection of non-culturable pathogens is not possible2. By following the conventional methodology, the detection of E. coli O157 takes around 3 days, Salmonella 4–6 days and Vibrio parahaemolyticus around 7 days3. For this reason, new techniques emerged which provide faster, more reliable and sensitive results; some of the most widely used are the polymerase chain reaction (PCR) and loop mediated isothermal amplification (LAMP). In PCR, the amplification process involves the repeating of three temperature steps. The first step corresponds to DNA double-strand denaturation, the second step involves the primers hybridization and the last one is the DNA extension4. After 35–40 cycles, it is possible to obtain thousands to millions of copies starting with a single copy of DNA as a template5.

Diverse pathogens in food have been identified by PCR; among them are E. coli6, Salmonella7, V. parahaemolyticus8, C. perfringens9, and L. monocytogenes10. Nevertheless, to carry out the PCR, a PCR machine is necessary, and the product needs to be loaded on agarose gel, stained with dye and visualized under UV light11. These limitations make PCR a difficult technique to be used in the field.

On the other hand, the LAMP technique developed by Notomi et al.12 amplifies DNA through the use of four primers which recognize six distinct sequences in the target DNA. The complete protocol is quicker; the reaction is performed under isothermal conditions and completed in 1 h or less13. Food-borne pathogens identified by this technique are Salmonella14, S. aureus15, Campylobacter16, and L. monocytogenes17. In this study, we demonstrated that the LAMP reaction has great sensitivity for detecting S. aureus samples with various concentrations. The LAMP reaction can be analyzed by agarose gel electrophoresis or other detection methods. However, these post-amplification detection techniques require opening of the reaction tubes, which increases the risk of sample contamination. To reduce this risk, products of LAMP amplification can be visualized through fluorescence signal by adding diverse dyes such as SYBR green, calcein, SYTO 9 or berberine1820. Some dyes enable the identification of a positive or negative sample with the naked eye through color change. For example, the use of gold nano-particles in LAMP generates a color change from transparent to pink on positive reactions21. On the other hand, the use of hydroxy naphtol blue (HNB) shows a purple coloration in negative reactions compared with a blue coloration in positive ones19. Another detection method is analyzing the turbidity derived from magnesium pyrophosphate precipitation which is the by-product of LAMP reactions22. In this study, we showed that the application of dyes such as HNB which can be seen with the naked eye and SYBR Safe dye which only needs a blue light to be seen, is an easy way to visually distinguish between positive and negative results.

The evaluation of color change, however, will be dependent on the users’ eye sensitivity to color. For this reason, there is a necessity to develop a device which will help to quantitatively interpret the result in a fast and accurate way and also reduce issues such as false positives. In this study, we developed a novel rapid detection platform that combines a user-friendly, portable LAMP reaction device and a smartphone-based detection system, which enables point-of-cared (POC) testing and diagnostics. This cost-efficient device controls a low-powered isothermal heating module and a LED excitation module via an Arduino microcontroller. The device contains a reaction cuvette to carry out LAMP reaction in the isothermal heater and a USB camera to take an image of the reagent inside the cuvette which is illuminated by an LED. The captured image is processed by a smartphone application developed specifically for this study.

Materials and methods

Biological material and DNA extraction

Staphylococcus aureus and Serratia marcescens strains were grown in Luria–Bertani broth at 30 °C and shaken for 24 h. MRS broth was employed to generate the Lactobacillus casei biomass at 35 °C with agitation by 24 h. The cells were then centrifuged at 5000×g for 10 min. The supernatant was discarded, and the pellet was used to do the DNA extraction. To carry out this objective, the GeneJet Genomic DNA Purification kit (Thermo Scientific) was used, and the provider instructions were thoroughly followed. DNA quality was evaluated through agarose gel electrophoresis and quantified with Nanodrop 2000 (Thermo Scientific). Furthermore, defatted milk was inoculated with S. aureus at different concentrations; samples were boiled for 10 min and centrifuged at 10,000×g. The supernatant was stored at 4 °C until its use as a DNA template in the LAMP reaction.

Primers design and LAMP amplification

To detect S. aureus, oligonucleotides were designed based on the FemA gene (DQ352463.1). The primers design was done by Primer Explorer V5 software (http://primerexplorer.jp/lampv5e/index.html). The primer set targeted six regions on the gene via a forward inner primer (FIP), a backward inner primer (BIP), two outer primers (F3 and B3). The best set of primers were FIP 5′CAAAGCCATCATTCTCACGGGTA-ACTTTGTACAAAATCCATCATTGG3′, BIP 5′ACGACAATAACAAAGTAATTGCAGC-AACATAACTTCCCATAGTAGGA3′, F3 5′TTAACTGTTACCGAATTTGACA3′ and B3 5′CCATTACTGGACCACGATTC3′. The oligonucleotides were synthesized by Eurofins Genomics. A typical LAMP reaction consisted of 1 × WarmStart Master Mix (Biolabs), 1.6 μM of FIP and BIP and 0.2 μM of F3 and B3 oligonucleotides. Finally, several DNA and CFU concentrations were used as a template in the final volume reaction of 25 μL. The mix was incubated in a water bath at 65 °C for 45 min and then stopped at 90 °C for 10 min. For visual detection we used both 120 μM of HNB and 1 μL of SYBR Safe dye (Invitrogen) which was previously diluted 1:10. SYBR safe dye was included during the incubation of samples to prevent any contamination and to ensure quantification in one step with the apparatus. LAMP products were visualized through agarose gel under a blue light transilluminator and with the naked eye.

Design of a portable device for LAMP reaction

We developed a novel rapid detection platform that combines a user-friendly and portable LAMP reaction device (Fig. 1a) and the smartphone-based detection system (Fig. 3), which enables point-of-cared (POC) testing and diagnostics. The LAMP reaction device requires a heating element to heat up the fluorescence-based LAMP assay sample in the cuvette up to 65–70 °C. The Peltier module is used as the heating element in this device (see Figs. 1b and 2b). The Peltier module is a compact semi-conductor based electronic element that acts as a heat pump.

Figure 1.

Figure 1

(a) 3D design of portable LAMP detection device; (b) schematic of cuvette encased by Peltier module.

Figure 3.

Figure 3

Fluorescent image of a sample captured by a smart phone application.

Figure 2.

Figure 2

(a) 3d-printed apparatus for LAMP reaction, (b) cuvette holder heated by Peltier Module.

The device contains a printed circuit board (PCB) powered by an Arduino Nano microcontroller that allows the heating unit to reach and maintain a specific temperature and the system to notify the completion of the LAMP reaction. Four AA 2500-mAh rechargeable batteries are used to power the heating unit and the LED screen that displays temperature, battery charge level and heating completion message. These batteries also power a light-emitting diode (LED) to illuminate the cuvette containing the fluorescence-based assay sample. Figure 2 shows the 3D-printed apparatus for LAMP reaction and the cuvette holder. The excitation signal for the fluorescent dye is provide by an LED. The light beam is passed through the cuvette where a portion of light is absorbed and the rest is emitted. The light emission is captured by a USB camera installed within the device. USB cameras have a short focal length and are compatible with Android. The captured images are uploaded and analyzed on a smartphone app to correlate the fluorescence intensity with S. aureus concentration.

Smartphone application programming

A smartphone software application (app) was developed and used to process images to quantify the bacterial count. The app can be used intuitively, requiring minimal input from an untrained user. The app algorithm for fluorescent signal measurement involves capturing, storing and processing the image of the sample23. Color information from the image is extracted and matched with the Red, Green, Blue (RGB) values to assist the user in selecting the target color. The source code of the android app was created in the Android Studio Java language. Once an image is captured by the app, the pixel analysis is processed and the percentage value of matching pixels throughout the entire image, which is correlated with the target nucleic acid concentration, is calculated and displayed by pressing the analyze button (Fig. 3). The main function of the application is to allow the user to define the color of the emitted fluorescent light that will be utilized to detect the target within the sample. Once an image is taken, the application allows the user to interact with the selected image and allows for the touched pixel of the image to determine the RGB value. Further details are found in Reference23.

Results

DNA extraction and LAMP amplification

The quantification done with a nanodrop of genomic DNA from the S. aureus extraction yielded a concentration of 1480 ng/μL with a 230/260 ratio of 1.82. The visualization of the DNA in the agarose gel shows that the samples are not degraded. To evaluate the sensitivity of LAMP, different DNA concentrations were tested, ranging from 1000 ng to 10 pg. All the concentrations show the multiple bands, which is expected under this technique through agarose gel (Fig. 4a). With the SYBR Safe dye, the green–yellow fluorescence was observed under blue light on all samples containing the DNA template in comparison with the no template control (NTC) which had an orange–yellow color (Fig. 4b). On the other hand, reactions with HNB dye show a blue color in the positives and a purple color in the negative reaction (Fig. 4c). Sensitivity on direct detection of S. aureus in inoculated milk samples was observed from 109 to 104 CFU/mL (Fig. 5).

Figure 4.

Figure 4

Sensitivity of LAMP amplification. (a) LAMP products visualized in 2% agarose gel containing different genomic DNA concentrations from S. aureus ranging from 1000 to 0.01 ng. DNA size marker is shown in leftmost lane; and a no template control (NTC) is shown in rightmost lane. “M” indicates “molecular-weight size marker.” (b) LAMP products with SYBR safe dye observed under blue light at different DNA concentrations. (c) LAMP products observed under naked eye with HNB dye with different DNA concentrations.

Figure 5.

Figure 5

Sensitivity of LAMP in milk samples. (a) LAMP products visualized in 2% agarose gel. DNA size marker is shown in leftmost lane; and a no template control (NTC) is shown in rightmost lane. “M” indicates “molecular-weight size marker.” (b) LAMP amplification products with SYBR safe as a dye observed under blue light from milk samples contaminated at several concentrations of S. aureus (109–104 CFU/mL).

To evaluate the specificity of the primers, DNAs from Serratia marcescens and Lactobacillus casei were employed as a control. Both strains show an orange color in the tube (Fig. 6), these assays prove that in-silico designed primers are targeting S. aureus and there is no cross detection with other bacterial strains.

Figure 6.

Figure 6

Specificity of LAMP primers to detect S. aureus. A LAMP reaction was developed against other species bacteria to evaluate their specificity against S. aureus (Sa). In both bacteria tested there is no green fluorescence indicating that there is no cross reaction with Serratia marcescens (Sm) and Lactobacillus casei (Lc); which show a coloration like the non-template tube (NTC).

Mobile application for color sensitivity assay detection

Using the proposed smartphone detection system, we analyzed LAMP products with various bacterial load levels. Experiments were performed to measure LAMP assay samples containing different concentrations of S. aureus (109 CFU/mL, 106 CFU/mL, and 103 CFU/mL). Our app showed testing results of quantifying S. aureus by the fluorescent dye. Figure 7 shows the average percentages of fluorescence detected in assay. The app accommodated samples with S. aureus concentration from 103 to 109 CFU/mL, and it is apparent that the percentage of fluorescence and concentration of S. aureus have a linear relationship. From the present proof-of-concept study, this platform offers a portable, easy-to-use method for measuring S. aureus concentration with LAMP amplification.

Figure 7.

Figure 7

Fluorescence percentage (%) calculated by the smartphone app versus S. aureus concentration of LAMP assay with the cut-off (red dotted line).

Discussion

Staphylococcus aureus is one of the most important food-borne pathogen and control of S. aureus is a significant public health concern, especially in dairy products where several outbreaks of food poisoning have been identified24. Staphylococcus aureus can be introduced at almost every step of production. For this reason, it is crucial to implement food safety strategies to avoid contamination in handling and processing, as well as monitoring and diagnosing all these steps in a timely fashion to guarantee a pathogen-free product.

One of the most important concerns about S. aureus is the production of a wide array of toxins that can lead to food poisoning; however, staphylococcal food poisoning takes place when the pathogen populations exceed 105 cells per gram25. In this work, we were able to detect a lower number of cells, which allows us to identify S. aureus accurately and rapidly before it reaches toxic levels. Some of the desired elements in a diagnostic technique are its sensitivity and speed to obtain the results. Since the LAMP technique was developed, it has been used as an important diagnostic tool. The LAMP is relatively easy to perform with high sensitivity. In this work we were not able to detect DNA concentrations lower than 10 pg using this set of primers. However, in the previous work of Sheet et al.26, S. aureus was detected by LAMP using primers based on the gene nuc with a sensitivity of 0.052 pg and 9 × 102 CFU/mL. The femA gene was selected because of its high conservation in S. aureus isolates and its previous successful use as a molecular marker in PCR and recently in LAMP27,28.

In this work, the LAMP assay works with 0.01 ng of DNA. Previous study reports that 1 ng of DNA template or less is essential for the LAMP detection compared with the PCR detection where 10 ng are necessary. It makes LAMP 10 times more sensitive than PCR. Nevertheless, LAMP is less sensitive than nested PCR and qPCR29. To compare the sensitivity of LAMP versus qPCR for detecting S. aureus, we reproduced the assay reported by Kim et al.30 with genomic DNA from S. aureus. We were able to detect 1 pg of DNA and calculated a limit of detection (LOD) of 1.3 pg with qPCR. The result can be found in the supplementary information (Supplementary Fig. S1). This sensitivity analysis showed that qPCR was more sensitive than LAMP at detecting S. aureus DNA and CFU as a template, which is consistent with published results30. However, in terms of reaction time, LAMP reactions are very fast (< 60 min) as no thermocycling steps and specialized equipment are necessary; and results can be obtained in as little as 15 min31.

A common problem found in LAMP experiments is the amplification in the negative control; this issue has been reported in previous research. Also, the mispriming in LAMP reactions can result in incorrect interpretations such as false positives32. The provider recommends carrying out the standardization of the LAMP reaction. This can be done through the standardization of the pH, purity and ratio of the oligonucleotides, dye and DNA concentration as well as temperature and reaction time. Furthermore, cross contamination can occur when the lids of the reaction tube are opened. To prevent it, the use of agar capsules has been proposed33. In addition, precautions must be taken during the master mix preparation. For instance, working in separate areas and the use of micropipettes exclusive to the LAMP experiments, filter tips, DNAse and RNAse-free tubes and keeping the workstation clean through the use of bleach are recommended (Supplementary Figs. S2 and S3).

This project's LAMP reaction and detection platform offers closed-tube fluorescent monitoring that does not require opening the tube after amplification. The application developed and used in this study calculated the percentage value of matching pixels throughout the entire image using the selected RGB value of the fluorescent signal. This percentage value was correlated with the bacterial load concentration for which the coefficient of determination (R2) equals 0.986. This study combines an effective image processing algorithm coded into a smartphone app with an inexpensive 3D printed apparatus that eliminated inaccurate visual monitoring and allowed for the quantification of bacterial load and nucleic acid concentration. The portable LAMP reaction and detection platform will eliminate the need for dedicated laboratory equipment for thermal cycling to operate polymerase chain reaction (PCR) amplification. The present closed tube amplification eliminates the risk of carry-over contamination and enables the real-time quantification of the amplified DNA for endpoint real-time analysis. From the present proof-of-concept study, this platform based on fluorescence imaging/detection offers a portable, simplified method to measure target pathogens with LAMP amplification.

Supplementary Information

Supplementary Figure S1. (35.6KB, docx)
Supplementary Figure S2. (141.8KB, docx)
Supplementary Figure S3. (125.9KB, docx)

Acknowledgements

This work is supported by “ALFA-IoT-Alliance for Smart Agriculture in the Internet of Things Era” (Award Number 2018-38422-28564) and the Agriculture and Food Research Initiative-Agricultural Workforce Training Priority Area (Grant No. 2021-67037-10692/Project Accession No. 1025548), from the U.S. Department of Agriculture, National Institute of Food and Agriculture. We also thank Consejo Nacional de Ciencia yTecnología (CONACyT), México for their support.

Author contributions

P.C.-A. and Y.H.P. wrote the main manuscript text; E.P. designed LAMP primer and performed LAMP experiments; E.D. designed and supervised overall experiments; M.M. conducted PCR tests; D.V.-R., H.T., and J.E. designed the 3D-printed device; J.S. helped develop the smartphone app algorithm.

Dara availability

The data sets used in this study are available upon reasonable request from the corresponding authors.

Competing interests

The authors declare no competing interests.

Footnotes

Publisher's note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Supplementary Information

The online version contains supplementary material available at 10.1038/s41598-022-25190-6.

References

  • 1.Bintsis T. Foodborne pathogens. AIMS Microbiol. 2017;3:529–563. doi: 10.3934/microbiol.2017.3.529. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 2.Law JW, Mutalib NA, Chan K, Lee H. Rapid methods for the detection of foodborne bacterial pathogens: Principles, applications, advantages and limitations. Front. Microbiol. 2015;5:770. doi: 10.3389/fmicb.2014.00770. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 3.Li Y, Fan P, Zhou S, Zhang L. Loop-mediated isothermal amplification (LAMP): A novel rapid detection platform for pathogens. Microb. Pathog. 2017;107:54–61. doi: 10.1016/j.micpath.2017.03.016. [DOI] [PubMed] [Google Scholar]
  • 4.Lorenz TC. Polymerase chain reaction: Basic protocol plus troubleshooting and optimization strategies. J. Vis. Exp. 2012;63:e3998. doi: 10.3791/3998. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 5.Ehtisham M, Wani F, Wani I, Kaur P, Nissar S. Poymerase chain reaction (PCR): Back to basics. Indian J. Contemp. Dent. 2016;4:30–35. doi: 10.5958/2320-5962.2016.00030.9. [DOI] [Google Scholar]
  • 6.Godambe LP, Bandekar J, Shashidhar R. Species specific PCR based detection of Escherichia coli from Indian foods. 3 Biotech. 2017;7:130. doi: 10.1007/s13205-017-0784-8. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 7.Gwida MM, Al-Ashmawy MAM. Culture versus PCR for Salmonella species identification in some dairy products and dairy handlers with special concern to its zoonotic importance. Vet. Med. Int. 2014;2014:502370. doi: 10.1155/2014/502370. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 8.Federici S, Serrazanetti DI, Guerzoni ME, Campana R, Ciandrini E, Baffone W, Gianotti A. Development of a rapid PCR protocol to detect Vibrio parahaemolyticus in clams. J. Food Sci. Technol. 2018;55:749–759. doi: 10.1007/s13197-017-2986-9. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 9.Anwar Z, Regan SB, Linden J. Enrichment and detection of Clostridium perfringens toxinotypes in retail food samples. J. Vis. Exp. 2019;152:e59931. doi: 10.3791/59931. [DOI] [PubMed] [Google Scholar]
  • 10.Niederhauser C, Candrian U, Höfelein C, Jermini M, Buhler HP, Luthy J. Use of polymerase chain reaction for detection of Listeria monocytogenes in food. Appl. Environ. Microbiol. 1992;58:1564–1568. doi: 10.1128/aem.58.5.1564-1568.1992. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 11.Lee PY, Costumbrado J, Hsu C, Kim YH. Agarose gel electrophoresis for the separation of DNA fragments. J. Vis. Exp. 2012;62:3923. doi: 10.3791/3923. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 12.Notomi T, Okayama H, Masubuchi H, Yonekawa T, Watanabe K, Amino N, Hase T. Loop-mediated isothermal amplification of DNA. Nucleic Acids Res. 2000;28:e63. doi: 10.1093/nar/28.12.e63. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 13.Parida M, Sannarangaiah S, Dash PK, Rao PVL, Morita K. Loop mediated isothermal amplification (LAMP): A new generation of innovative gene amplification technique; perspectives in clinical diagnosis of infectious diseases. Rev. Med. Virol. 2008;18:407–421. doi: 10.1002/rmv.593. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 14.Wang L, Shi L, Alam MJ, Geng Y, Li L. Specific and rapid detection of foodborne Salmonella by loop-mediated isothermal amplification method. Food Res. Int. 2008;41:69–74. doi: 10.1016/j.foodres.2007.09.005. [DOI] [Google Scholar]
  • 15.Yang H, Ma X, Zhang X, Wang Y, Zhang W. Development and evaluation of a loop-mediated isothermal amplification assay for the rapid detection of Staphylococcus aureus in food. Eur. Food Res. Technol. 2011;232:769–776. doi: 10.1007/s00217-011-1442-8. [DOI] [Google Scholar]
  • 16.Romero MR, Cook N. A rapid LAMP-based method for screening poultry samples for Campylobacter without enrichment. Front. Microbiol. 2018;9:2401. doi: 10.3389/fmicb.2018.02401. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 17.Birmpa A, Kalogeropoulos K, Kokkinos P, Vantarakis A. Evaluation of two loop-mediated isothermal amplification methods for the detection of Salmonella enteritidis and Listeria monocytogenes in artificially contaminated ready-to-eat fresh produce. Ital. J. Food Saf. 2015;4:5383. doi: 10.4081/ijfs.2015.5383. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 18.Zhou D, Guo J, Xu L, Gao S, Lin Q, Wu Q, Wu L, Que Y. Establishment and application of a loop-mediated isothermal amplification (LAMP) system for detection of cry1Ac transgenic sugarcane. Sci. Rep. 2014;4:4912. doi: 10.1038/srep04912. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 19.Goto M, Honda E, Ogura A, Nomoto A, Hanaki K. Colorimetric detection of loop-mediated isothermal amplification reaction by using hydroxy naphthol blue. Biotechniques. 2009;46:167–172. doi: 10.2144/000113072. [DOI] [PubMed] [Google Scholar]
  • 20.Fischbach J, Xander NC, Frohme M, Glökler JF. Shining a light on LAMP assays' A comparison of LAMP visualization methods including the novel use of berberine. Biotechniques. 2018;58:189–194. doi: 10.2144/000114275. [DOI] [PubMed] [Google Scholar]
  • 21.Srimongkol G, Ditmangklo B, Choopara I, Thaniyavarn J, Dean D, Kokpol S, Vilaivan T, Somboonna N. Rapid colorimetric loop-mediated isothermal amplification for hypersensitive point-of-care Staphylococcus aureus enterotoxin A gene detection in milk and pork products. Sci. Rep. 2020;10:7768. doi: 10.1038/s41598-020-64710-0. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 22.Mori Y, Nagamine K, Tomita N, Notomi T. Detection of loop-mediated isothermal amplification reaction by turbidity derived from magnesium pyrophosphate formation. Biochem. Biophys. Res. Commun. 2001;289:150–154. doi: 10.1006/bbrc.2001.5921. [DOI] [PubMed] [Google Scholar]
  • 23.Rojas-Barboza D, Park E, Sassenfeld R, Winder J, Smith GB, Valles-Rosalles D, Delgado E, Park YH. Rapid, simple, low-cost smartphone-based fluorescence detection of Escherichia coli. Int. J. Agric. Biol. Eng. 2021;14:189–193. [Google Scholar]
  • 24.Kadariya J, Smith TC, Thapaliya D. Staphylococcus aureus and staphylococcal food-borne disease: An ongoing challenge in public health. Biomed Res. Int. 2014;14:827965. doi: 10.1155/2014/827965. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 25.Argaw S, Addis M. A review on Staphylococcal food poisoning. Food Sci. Qual. Manag. 2015;40:59–71. [Google Scholar]
  • 26.Sheet O, Grabowski NT, Klein G, Abdulmawjood A. Development and validation of a loop mediated isothermal amplification (LAMP) assay for the detection of Staphylococcus aureus in bovine mastitis milk samples. Mol. Cell. Probes. 2016;30:320–325. doi: 10.1016/j.mcp.2016.08.001. [DOI] [PubMed] [Google Scholar]
  • 27.Riyaz-Ul-Hassan S, Verma V, Qazi GN. Evaluation of three different molecular markers for the detection of Staphylococcus aureus by polymerase chain reaction. Food Microbiol. 2008;25:452–459. doi: 10.1016/j.fm.2008.01.010. [DOI] [PubMed] [Google Scholar]
  • 28.Meng X, Zhang G, Sun B, Liu S, Wang Y, Gao M, Fan Y, Zhang G, Shi G, Kang X. Rapid detection of mecA and femA genes by loop-mediated isothermal amplification in a microfluidic system for discrimination of different Staphylococcal species and prediction of methicillin resistance. Front. Microbiol. 2020;11:1487. doi: 10.3389/fmicb.2020.01487. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 29.Khan M, Wang R, Li B, Liu P, Weng Q, Chen Q. Comparative evaluation of the LAMP assay and PCR-based assays for the rapid detection of Alternaria solani. Front. Microbiol. 2018;9:1–9. doi: 10.3389/fmicb.2018.02089. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 30.Kim E, Yang S-M, Won J-E, Kim D-Y, Kim D-S, Kim H-Y. Real-time PCR method for the rapid detection and quantification of pathogenic Staphylococcus species based on novel molecular target genes. Foods. 2021;10:2839. doi: 10.3390/foods10112839. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 31.Reddy RVC, Satya AK, Surendra KSNL, Rana SK, Subramanian BM, Sharma GK, Srinivasan VA. Reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay for the detection of rabies virus. Adv. Anim. Vet. Sci. 2016;4:584–592. doi: 10.14737/journal.aavs/2016/4.11.584.592. [DOI] [Google Scholar]
  • 32.Hardinge P, Murray JAH. Reduced false positives and improved reporting of loop-mediated isothermal amplification using quenched fluorescent primers. Sci. Rep. 2019;9:7400. doi: 10.1038/s41598-019-43817-z. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 33.Karthik K, Rathore R, Thomas P, Arun TR, Viswas KN, Dhama K, Agarwal RK. New closed tube loop mediated isothermal amplification assay for prevention of product cross-contamination. MethodsX. 2014;1:137–143. doi: 10.1016/j.mex.2014.08.009. [DOI] [PMC free article] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

Supplementary Figure S1. (35.6KB, docx)
Supplementary Figure S2. (141.8KB, docx)
Supplementary Figure S3. (125.9KB, docx)

Data Availability Statement

The data sets used in this study are available upon reasonable request from the corresponding authors.


Articles from Scientific Reports are provided here courtesy of Nature Publishing Group

RESOURCES