Skip to main content
United European Gastroenterology Journal logoLink to United European Gastroenterology Journal
. 2022 Sep 7;10(9):973–982. doi: 10.1002/ueg2.12307

Diagnostic accuracy of pan‐enteric capsule endoscopy and magnetic resonance enterocolonography in suspected Crohn's disease

Jacob Broder Brodersen 1,2,, Torben Knudsen 1,2, Jens Kjeldsen 3,4,5, Mie Agerbæk Juel 6, Søren Rafael Rafaelsen 2,7, Michael Dam Jensen 6
PMCID: PMC9731660  PMID: 36069336

Abstract

Background and Aims

Magnetic resonance enterocolonography (MREC) and pan‐enteric capsule endoscopy (CE) offers visualization of the entire gastrointestinal tract in a single examination. We examined the diagnostic accuracy of MREC and CE in patients with suspected Crohn's disease (CD).

Method

In a prospective, blinded, multicenter study, we included patients with clinically suspected CD. Patients were examined with MREC, CE, and ileocolonoscopy (IC) within 2 weeks. The primary outcome was per patient sensitivity, specificity, and diagnostic accuracy for ileocolonic CD. IC served as reference standard.

Results

153 patients were included in the study and IC, MREC, and CE was performed in 152, 151, 133 patients, respectively. CD was diagnosed with IC in 59 (39%) patients (terminal ileum (TI) 22, colon 20, TI and colon 17). The sensitivity and specificity for diagnosing ileocolonic CD with MREC was 67.9% (CI 53.7–80.1) and 76.3% (CI 65.2–85.3) (TI 76.9% and 85.6%; colon 27% and 93%) compared to 87.5% (CI 73.2–95.8) and 87.8% (CI 78.2–94.3) with CE (TI 96.6% and 87.5%; colon 75.0% and 93.0%). The sensitivity of CE was superior to that of MREC (p = 0.02). The patient experienced discomfort was equal with CE and MREC and significantly less than with IC.

Conclusion

In patients with suspected CD, CE has a high sensitivity for diagnosing CD in the TI and colon, which is superior to that of MREC. The sensitivity of MREC for diagnosing CD in the colon is poor. CE could be a patient‐friendly alternative to IC in selected patients with suspected CD.

Registered at ClinicalTrials.gov: NCT03134586.

Keywords: capsule endoscopy, Crohn's disease, diagnostic imaging, magnetic resonance imaging


Key summary.

Summarize the established knowledge on this subject

  • Ileocolonoscopy is the recommended first line examination in clinically suspected Crohn's disease (CD); however, disease assessments require multiple tests due to the segmental inflammation throughout the gastrointestinal tract in CD.

  • Magnetic resonance imaging (MRI) and capsule endoscopy are established modalities for detection of small bowel CD.

  • Previous studies on the diagnostic accuracy of ileocolonic CD with MRI and capsule endoscopy is primarily on patients with established CD.

  • The diagnostic accuracy of MRI and capsule endoscopy for suspected ileocolonic CD is undetermined.

What are the significant and/or new findings of this study?

  • In suspected ileocolonic Crohn's disease, the sensitivity of capsule endoscopy is high and superior to MRI.

  • The sensitivity of MRI for diagnosing early Crohn's disease in the colon is poor.

  • The image quality did not affect the diagnostic accuracy of capsule endoscopy.

  • Capsule endoscopy could be an alternative to ileocolonoscopy in selected patients with suspected CD.

INTRODUCTION

Crohn's disease (CD) is an idiopathic chronic inflammatory bowel disease characterized by transmural inflammation with a segmental distribution. The disease may affect any part of the gastrointestinal tract, although most patients have CD located in the terminal ileum and/or colon. 1 Hence, ileocolonoscopy (IC) is the first line diagnostic procedure in patients with suspected CD. Regardless of findings at IC an additional examination of the small bowel is recommended. 2 IC is invasive and reaching the terminal ileum is not always possible. 2 , 3 Although significant adverse events such as bleeding and perforation are rare (<0.1%), 4 up to one third of the patients experience minor adverse events, for example, abdominal pain and bloating. 5

Recent technological advances in gastrointestinal imaging and endoscopy have greatly improved modalities for pan‐enteric, non‐invasive and patient‐friendly diagnosis of CD. Magnetic resonance imaging (MRI), intestinal ultrasound, and capsule endoscopy (CE) are the main modalities currently used complementary to IC in the diagnostic work‐up of CD. Both CE and MRI are well established modalities for evaluating the small intestine. 6 , 7 , 8 Their diagnostic accuracy for detecting CD in the colon has not been investigated to the same extend; especially not in the initial work‐up of CD. MREC has shown a moderate to high sensitivity for detecting CD in the colon and a good correlation with IC for assessing disease severity in patients with known CD. 7 , 9 , 10 Similar, colonic evaluation with CE is safe with a substantial agreement between CE and IC 11 , 12 and a high diagnostic accuracy. 13 Whether these modalities can replace IC in the future, as the initial diagnostic modality in selected patients with suspected CD is unknown.

The aim of this study was to compare the diagnostic accuracy, feasibility, and patient experienced discomfort with pan‐enteric CE and MREC for the initial diagnosis of ileocolonic CD compared to the current standard (IC).

METHODS

Study design and participants

This was a prospective, blinded, multicenter study of the diagnostic accuracy, image quality, and patient experienced discomfort with CE and MREC in patients with suspected CD. The study was conducted in accordance with the STARD 2015 reporting guideline for diagnostic accuracy studies. 14

Patients were recruited from three centers in the Region of Southern Denmark managing adult patients with inflammatory bowel diseases. Eligible subjects were ≥16 years of age with a clinical suspicion of CD defined as diarrhea and/or abdominal pain for more than 1 month (or repeated episodes of diarrhea and/or abdominal pain) associated with negative serologic markers for celiac disease, negative stool culture (or polymerase chain reaction) for pathogenic bacteria, a fecal calprotectin >50 mg/kg and at least one additional finding suggesting CD: elevated inflammatory markers, anemia, fever, weight loss, perianal abscess/fistula, a family history of inflammatory bowel disease, or a prior flexible sigmoidoscopy suggestive of CD. Use of NSAID's, renal failure, known gastrointestinal disorder, drug abuse, pregnancy, acute bowel obstruction, implanted magnetic foreign bodies or an IC performed within 3 months prior to inclusion were exclusion criteria (detailed criteria listed in Supporting Information S1 and S2). Patients were enrolled from June 2016 to July 2020. All patients had standardized clinical work‐up including medical history, physical examination, bowel ultrasonography, blood samples, IC with biopsies, CE, and MREC within a 2‐week period. Patients who failed to undergo IC were excluded from the study.

All examinations were performed by specialists, blinded to the results of the other imaging modalities and findings were reported in a standardized fashion ‐ including whether or not CD was evident.

Diagnostic criteria

IC served as the reference standard for diagnosing CD in the terminal ileum and colon. Clinical information was available to the assessor of the reference standard. CD was defined endoscopically (IC & CE) by the presence of more than three ulcerations (aphthous lesions or ulcers), irregular ulcers/fissures, or stenosis caused by fibrosis or inflammation. 6 , 15 Stenosis was defined as a luminal narrowing passable (low grade) or impassable (high grade) by the endoscope. For diagnosing CD with MREC, the following findings were evaluated: mucosal ulcerations, bowel wall thickening (≥3 mm), bowel wall hyper‐enhancement, diffusion restriction, bowel stenosis, creeping fat, dilated vasa recta, and the presence of an abscess or fistula in conjunction to a diseased bowel segment. 16 The diagnosis was based on an overall evaluation of lesions consistent with CD.

MREC

MREC was performed after overnight fasting with a 1.5 T Philips Intera MRI unit (Eindhoven, Netherlands) with Syn‐body coil. A total of 1 L of Mannitol 7.5% solution was ingested 1.5 h before the examination. Hyoscine butylbromide 20 mg was administered intravenously in order to reduce artifacts from bowel peristalsis. 15 ml gadoterate meglumine (0.5 mmol/ml) (Dotarem®, Guerbet, Raleigh, North Carolina, USA) was administered intravenously for post contrast assessment. Images were recorded with cor T2, B‐FFE, T1, SPIR, axial T1w and diffusion weighted sequences.

The small intestine was divided into thirds (proximal, middle and distal third), and the colon was divided into six segments: cecum, ascending, transverse, descending, sigmoid colon, and rectum. Disease severity was assessed with MaRIA score. 10 , 17

Pan‐enteric CE

CE was performed with the PillCam™ Colon‐2 capsule (n = 43) and once commercially available the PillCam™ Crohn's capsule (n = 90) (Medtronic, Dublin, Ireland) after overnight fasting and bowel preparation with 2 + 2 liters of Polyethylene glycol plus ascorbate (Moviprep®, Norgine, Amsterdam, Netherlands) and Sodium Phosphate booster as previously described by European Society of Gastrointestinal Endoscopy. 18 Images were reviewed with PillCam™ software v9. The small intestine was divided into thirds by the software. The colon was divided into five segments: Cecum, ascending colon, transverse colon, descending/sigmoid colon and rectum. The right and left flexures were used as landmarks for this subdivision. A complete small bowel evaluation was defined by capsule passage to the colon. Capsule expelled from the rectum defined a complete colon examination. The ileocolonic disease severity was assessed with the Simple Endoscopic Score for Crohn's Disease (SES‐CD) 19 and disease severity in the small intestine was assessed with the Lewis score. 20

Ileocolonoscopy

IC was performed according to standard clinical practice after bowel preparation with sodium picosulfate (Picoprep®, Ferring Pharmaceuticals, Saint‐Prex, Switzerland), and type of sedation was recorded (midazolam/fentanyl or propofol). If IC was performed the day after CE, the patients remained on a clear liquid diet and received no further bowel preparation. Complete IC was documented by intubation of the terminal ileum. The length of terminal ileum intubation was estimated and the reason for unsuccessful intubation was recorded. The ileocolonic disease severity was assessed with SES‐CD. 19

Data management and collection

Study data were collected and managed using REDCap electronic data capture tools hosted at OPEN—Region of Southern Denmark. 21 All authors had access to the study data, reviewed and approved the final manuscript. The trial protocol and data underlying this article will be shared on reasonable request to the corresponding author.

Statistical analyses

Based on previous studies by our group using similar inclusion criteria, 6 the prevalence of CD was estimated to be 40%–50%. With a prevalence of 50% and a targeted sensitivity of 90%, 70 patients with CD and 70 without CD was needed to achieve a lower limit of the 95% confidence interval (CI) of at least 0.75. 22 We aimed to include 150 patients.

Continuous data were summarized using descriptive statistics. The sensitivity, specificity and diagnostic accuracy of CE and MREC for diagnosing CD in the terminal ileum and colon was calculated on 2 × 2 tables. Diagnostic accuracies were compared by area under receiver operator characteristic curve (AUC) and differences in sensitivity and specificity were tested with McNemar's test. 23 Due to a small number of discordant pairs, we used the mid‐p McNemar's test to obtain the two‐sided mid‐p‐value. 24 Sensitivity and specificity analyses for CE and MREC were performed on (1) the total number of patients examined with CE or MREC compared to IC including examinations with segments not fully visualized with CE or IC, and (2) subjects who were examined with all three modalities, had segments fully visualized and no protocol deviation (per protocol analysis). The latter for a direct comparison of CE and MREC compared to IC and test of significance. To assess if misclassification between CD and ulcerative colitis (UC) affects the diagnostic accuracy, a combined variable of both diagnoses was created. CD detected in the small bowel proximal to the terminal ileum was reported as diagnostic yield, and differences were tested for statistical significance in a clustered logistic regression model. Only PillCam™ Crohn's capsules were included in diagnostic yield, due to more reliable small bowel assessment. A non‐parametric test was used to compare differences in patient experienced discomfort with CE, MREC and IC with different types of sedation (Wilcoxon matched‐pairs signed‐ranks test or Kruskal–Wallis test). Statistical analyses were performed using Stata (StataCorp. 2019. Stata Statistical Software: Release 16. College Station, TX: StataCorp LLC).

Ethical considerations, approvals and registration

The study was conducted in accordance with the principles of the Helsinki declaration and was approved by the local ethics committee of Southern Denmark (S‐20150189) and the Danish Data Protection Agency (16/10457). All patients gave informed consent before participation (oral and written). Before inclusion of adolescents between 15 and 17 years of age, both parents and the patient gave informed consent. The study was registered at ClinicalTrials.gov (NCT03134586).

RESULTS

A total of 153 patients were enrolled in the study, and 152 were examined in accordance with the protocol (Figure 1). The study population included 43 males and 109 females with a median age of 27 years (range 16–72). Patient characteristics are shown in Table 1. IC, MREC and CE was performed in 152, 151, 133 patients, respectively. A complete IC and CE was achieved in 130 (85.5%) and 109 (82.0%) patients.

FIGURE 1.

FIGURE 1

Flow chart showing the number of patients entering the study and completing examinations in accordance with the study protocol

TABLE 1.

Characteristics of 152 patients examined in the study

Gender (n) Male 43 (28%)
Female 109 (72%)
Age (years) Median 27
Range 16–72
Genetic predisposition (n) None 106 (70%)
Crohn's disease 31 (20%)
Ulcerative colitis 15 (10%)
BMI (kg/m2) Median 24.2
Range 17.1–57.2
Smoking status (n) Current 42 (28%)
Former 23 (15%)
Never 87 (57%)
Duration of symptoms (months) Median 6
Range 1.0–60
Symptoms (n) Abdominal pain 148 (97%)
Diarrhea 75 (49%)
Weight loss >3 kg 57 (38%)
No. of bowel movements Median 3
Range 1–17
C‐reactive protein (mg/L) Median 12
Range 0.2–122
Fecal calprotectin (mg/g) Median 516
Range 51–6000
CDAI (responders n = 98) Median 167.5
Range 20–387
Bowel resection before inclusion (n) 0
Non‐steroidal anti‐inflammatory drugs use (n) 0

Findings

IC diagnosed CD in 59 patients (39%). The Montreal classification is shown in Table 2. In comparison, CE detected CD in 51 (38.4%) patients (terminal ileum 22, colon 7, small bowel and colon 22), and MREC detected CD in 66 (43.7%) patients (small bowel 48, colon 14, small bowel and colon 4).

TABLE 2.

Montreal classification in 59 patients with CD detected by IC

n %
A1: ≤16 years 1 2%
A2: 17–40 years 47 80%
A3: >40 years 11 18%
L1: Ileal 22 37%
L2: Colonic 20 34%
L3: Ileocolonic 17 29%
B1: Luminal 54 91%
B2: Stricturing 4 7%
B3: Penetrating 1 2%

Diagnostic accuracy for ileocolonic CD

For MREC, the overall sensitivity and specificity for diagnosing CD in the terminal ileum or colon was 67.9% (CI 53.7–80.1) and 76.3% (CI 65.2–85.3)—terminal ileum 76.9% and 85.6%; colon 27% and 93%. For CE this was 87.5% (CI 73.2–95.8) and 87.8% (CI 78.2–94.3)—terminal ileum 96.6% and 87.5%; colon 75.0% and 93.0%. See Table 3 for full details.

TABLE 3.

Diagnostic accuracy of MREC and CE for diagnosing CD with IC as reference standard

All patients
  n Sensitivity (95% CI) Specificity (95% CI) PPV (95% CI) NPV (95% CI) ROC (95% CI) FP (n) FN (n)
Terminal ileum + colon MREC 129 67.9 (53.7–80.1) 76.3 (65.2–85.3) 66.7 (52.5–78.9) 77.3 (66.2–86.2) 0.72 (0.64–0.80) 18 17
CE 114 87.5 (73.2–95.8) 87.8 (78.2–94.3) 79.5 (64.7–90.2) 92.9 (84.1–97.6) 0.88 (0.82–0.95) 9 5
Terminal ileum MREC 129 76.9 (60.7–88.9) 85.6 (76.6–92.1) 69.8 (53.9–82.8) 89.5 (81.1–95.1) 0.81 (0.74–0.89) 13 9
CE 117 96.6 (82.2–99.9) 87.5 (78.7–93.6) 71.8 (55.1–85.0) 98.7 (92.8–100) 0.92 (0.87–0.97) 11 1
Colon MREC 151 27.0 (13.8–44.1) 93.0 (86.8–96.9) 55.6 (30.8–78.5) 79.9 (71.9–86.2) 0.60 (0.52–0.68) 8 27
CE 128 75.0 (50.9–91.3) 93.0 (86.1–97.1) 71.4 (47.8–88.7) 93.6 (85.7–97.9) 0.84 (0.76–0.93) 7 7
Per Protocol
  n Sensitivity (95% CI) Specificity (95% CI) PPV (95% CI) NPV (95% CI) ROC (95% CI) FP (n) FN (n)
Terminal ileum + colon MREC 98 66.7 (48.2–82.0) 73.8 (61.5–84.0) 56.4 (39.6–72.2) 81.4 (69.1–90.3) 0.70 (0.61–0.80) 17 11
CE 98 90.9 (75.7–98.1) 86.2 (75.3–93.5) 76.9 (60.7–88.9) 94.9 (85.9–98.9) 0.89 (0.82–0.95) 9 3
p‐value   0.02 0.08 0.002
Terminal ileum MREC 113 75.9 (56.5–89.7) 84.5 (75.0–91.5) 62.9 (44.9–78.5) 91.0 (82.4–96.3) 0.80 (0.71–0.89) 13 7
CE 113 96.6 (82.2–99.9) 86.9 (77.8–93.3) 71.8 (55.1–85.0) 98.6 (92.7–100) 0.92 (0.87–0.97) 11 1
p‐value   0.04 0.82 0.029
Colon MREC 98 10.0 (1.23–31.7) 92.3 (84.0–97.1) 25.0 (3.19–65.1) 80.0 (70.2–87.7) 0.51 (0.44–0.59) 6 18
CE 98 75.0 (50.9–91.3) 92.3 (84.0–97.1) 71.4 (47.8–88.7) 93.5 (85.5–97.9) 0.84 (0.74–0.94) 6 5
p‐value   <0.001 0.77 <0.001

Note: Sensitivities and specificities are stated in percentages, with the corresponding 95% CI intervals in parentheses. The positive predictive value (PPV), negative predictive value (NPV), area under receiver operator curve (ROC), and numbers of false positive (FP) and false negative (FN) are displayed. The difference in diagnostic sensitivity and specificity was tested for statistical significance and p‐values are reported. Per protocol analysis: Patients examined with all three modalities, segments fully visualized and no protocol deviation.

In the per protocol analysis, the sensitivity of CE was superior to that of MREC; especially for colonic disease (p < 0.001). There was no significant difference in specificity (p > 0.08). The AUC of CE was superior to that of MREC for both the terminal ileum and colon.

Proximal small bowel

In the proximal third of the small bowel MREC and CE detected CD in 2 of 151 (1.5%) and 11 of 90 patients (12%), respectively. In the middle third, MREC and CE found CD in 3 of 151 (2%) and 13 of 90 patients (14%). The combined diagnostic yield proximal to the terminal ileum was 4 (3%) and 14 (15.6%) with MREC and CE, respectively (p < 0.01). In 3 cases of complete IC, the terminal ileum was reported normal, but CE detected CD in the proximal small bowel (MREC detected 1 of the cases).

Disease activity

The median SES‐CD was 9.0 (range 1–21) with IC compared to 9.5 (range 2–28) with CE, and there was a strong correlation between modalities (Spearman's rho 0.82, p < 0.001). For the small bowel, CE found a mean Lewis score of 1784 (range 225–6060). MREC found a mean MaRIA score for the terminal ileum and overall of 13.7 (range 2.8–28.35) and 15.8 (range 2.8–47.4), respectively. There was a weak correlation between the global MaRIA score and SES‐CD with IC (Spearman's rho 0.2, p = 0.2).

Patient experienced discomfort

A total of 106 patients (69.7%) completed the questionnaire. There was no difference between MREC and CE in terms of physical and psychological discomfort (Table 4). Compared to IC, both MREC and CE was associated with less physical and psychological discomfort (p < 0.001). However, when IC was performed with propofol sedation, the discomfort was similar to that of MREC and CE.

TABLE 4.

Patient experienced discomfort with MREC, CE and IC

VAS p‐value
Mean (95% CI) Median Range MREC CE
Physical discomfort MREC 3.6 (3.0–4.2) 2.75 0–10 N/A 0.72
CE 3.4 (2.8–4.0) 3 0–10 0.72 N/A
IC 4.8 (4.1–5.4) 5 0–10 0.00 0.00
Midazolam, fentanyl 5.2 (4.5–5.8) 5 0–10 0.00 0.00
Propofol 3.6 (2.2–5.0) 2 0–10 0.74 0.81
Psychological discomfort MREC 2.0 (1.5–2.5) 1 0–10 N/A 0.72
CE 2.1 (1.6–2.6) 1 0–10 0.72 N/A
IC 3.1 (2.5–3.6) 2 0–10 0.00 0.01
Midazolam, fentanyl 3.2 (2.5–3.8) 2 0–10 0.00 0.00
Propofol 2.6 (1.6 3.7) 2 0–10 0.02 0.66

Note: Patients marked visual analog scales for physical and psychological discomfort after each examination. All scales were 10 cm long; 0 cm equaled no discomfort and 10 cm the worst imaginable discomfort. IC is divided into 2 subgroups depending on type of sedation used. The difference between CE, MREC and IC was tested for statistical significance and p‐values are reported.

Safety

Four (2.6%) cases of serious adverse events were recorded, and none of these had any lasting consequences for the patients. A 27 years old male with colonic cancer in the transverse colon had capsule retention. The patient did not experience symptoms of retention and subsequently underwent surgery. Three patients were admitted to hospital after IC, MREC and CE, respectively, due to discomfort and abdominal pain. The patients had no signs of bowel perforation or capsule retention. All patients were discharged after 6–8 h of observation.

Additional results

Additional findings and data on image quality are available in Supporting Information S1 and S2.

DISCUSSION

This prospective, blinded, multicenter study is, to the best of our knowledge, the largest study comparing the diagnostic accuracy of MREC and pan‐enteric CE in the initial diagnosis of ileocolonic CD. CE was superior to MREC for diagnosing CD in the terminal ileum and colon, and the diagnostic yield was higher for detection of CD in the proximal small bowel. In this population, MREC performed poorly for the colon. Patients' subjective experience of discomfort during MREC and CE was similar and significantly better compared to IC with midazolam/fentanyl sedation but not with propofol.

Visualizing the transmural component of CD (e.g. bowel wall thickening and post contrast enhancement) is a key finding with cross sectional imaging. In the majority of patients, CD often progress from luminal inflammation at the time of diagnosis to complicated disease involving the entire gut wall. 25 Therefore, comparing diagnostic studies is limited by spectrum bias, and transferring results from patients with known or complicated CD to patients with suspected or early CD may not be valid. This may explain why MREC performed poorly for the initial diagnosis of colonic CD against an endoscopic reference standard compared to previous studies of patients with known CD. 7 , 10 , 26 This was also shown in the METRIC trial, where the sensitivity of MREC for detection of colonic CD in patients with newly diagnosed CD was inferior to that of patients with known CD—47% and 84%, respectively. 7 Another issue could be the chosen diagnostic threshold or difficulty distinguishing between non‐specific inflammation, UC, and mild colonic CD. However, we did not find misclassification of the various types of inflammation to have a major impact on the diagnostic accuracy (Supporting Information S1 and S2). In line with the METRIC trial, our results indicate that MREC is not an optimal modality for diagnosing CD in a very early stage due to the low sensitivity for CD located in the colon. MREC is more suited for advanced CD with pronounced transmural inflammation and a higher frequency of disease complications (stenosis or penetrating lesions).

Achieving a complete examination is a common challenge with CE and IC. In this study, capsule excretion per rectum was achieved in 82% of patients, which is comparable to similar studies with suspected or known CD. 11 , 27 This should, however, be compared to the failure rate of IC (i.e. not intubating the terminal ileum), which was about 14% in our study and comparable to previous studies. 6 , 28 It should, however, be emphasized, that diagnoses can be made with incomplete examinations if signs of disease are detected.

Another limitation with CE is the technical inability to wash away or aspirate the contents of the colon, and extensive bowel preparation for a good visualization of the mucosa is required. In this study, the bowel cleansing was rated good or excellent in 75% of patients (Supporting Information S1 and S2), which is comparable to other studies. 13 , 29 Surprisingly, no difference was found in the overall diagnostic performance of CE when stratifying for the bowel cleansing and the overall negative predictive value of a complete CE was 95%. A reason for this could be the presence of multiple or extensive ulcerations in patients with CD detected irrespective of the image quality. This is an important observation and in line with a limited number of studies examining the feasibility of low‐volume bowel cleansing regimens. 30

Future diagnostic algorithms should strive for minimally invasive and patient‐friendly modalities. We found MREC and CE to be equivalent and better tolerated than IC in relation to both psychological and physical discomfort. However, using propofol sedation reduced the discomfort of IC to the same level as MREC and CE. Nevertheless, patients still experience discomfort and optimizing bowel cleansing and contrast regimens can further improve the patient experience.

The ability to detect various types of pathology is important if CE or MREC is used in patients with suspected CD. In this study, almost 10% of patients had UC, and cases of malignancy were detected with MREC and CE, although both modalities misclassified one case as CD (Supporting Information S1 and S2). This is a reminder that atypical presentations should trigger a targeted IC with biopsies, especially in the elderly patients.

Future perspective

Implementing pan‐enteric CE as a first‐line modality in patients with suspected CD, could reduce the need for IC; changing IC from a first line procedure to a targeted procedure for obtaining biopsies, or if CE is incomplete or contraindicated. Since pan‐enteric CE visualizes the entire small bowel, this offers a potential single‐examination strategy yielding the total disease distribution—in this study CE found CD proximal to the terminal ileum in 14 of 51 cases with CD on CE. This strategy might be feasible in young patients, who have a low risk of neoplasia. The potential is a rapid and less invasive diagnostic work‐up, which is better tolerated and possibly cost‐effective. 31 Future research should develop new diagnostic algorithms using minimally invasive technology, examine the feasibility of CE as a first‐line diagnostic procedure, reduce the time used for CE analysis (e.g. with artificial intelligence), implementing pan‐enteric scores, 32 and optimize bowel preparation, which will add further potential to this modality. MREC should be reserved for more advanced stages of CD to harvest the full potential of this modality.

Strengths and limitations

We included a clinically relevant population of patients with suspected CD eliminating reader expectation and spectrum bias. An accepted reference standard was applied, and readers were blinded to the results of other examinations. Hence, our results are valid for the first diagnostic work‐up of suspected ileocolonic CD. Diagnostic accuracies may not apply to the proximal small bowel. CE and MRI are, however, well established and recommended in the current guidelines for diagnosing small bowel CD. 2

An endoscopic reference standard might favor CE over MREC since both IC and CE evaluate the mucosa, whereas MREC primarily evaluate inflammation in the bowel wall. Nevertheless, current guidelines recommend IC as the first line examination, 2 and the earliest lesions of CD are believed to arise in the intestinal mucosa. 1 With this in mind, we consider IC an appropriate reference standard for the initial diagnosis of ileocolonic CD. We applied a widely accepted but not validated diagnostic criterion for the diagnosis of CD with CE. 15 Choosing another diagnostic threshold might have impacted the results. We used 2 types of capsules for CE, and they differs in terms of software and small bowel segmentation. However, this does not affect the ileocolonic evaluation. Findings in the upper and middle third of the small bowel is only presented for the PillCam™ Crohn's capsule.

Experienced gastroenterologists at each participating center performed IC and CE. Variations between multiple observers were not accounted for in this study. A single dedicated abdominal MRI specialist with more than 20 years' experience participated in the study. It is unknown whether the administration of rectal contrast or consensus decision between two or more radiologists would have altered the diagnostic accuracy of MREC. Studies of the inter‐observer variation for diagnosing colonic CD with MREC should clarify the latter. A recent study showed a fair agreement in newly diagnosed patients. 33

Instead of patency capsule, we primarily used MREC for securing bowel patency. The number of patients examined with CE could be slightly higher, however, if patients with stenosis at MREC had a patency capsule. 34

Conclusion

Pan‐enteric CE has a high accuracy for diagnosing CD in the small bowel and colon, which is superior to that of MREC. The sensitivity of MREC for diagnosing CD in the colon is poor. Both examinations are better tolerated than IC with conscious sedation. CE could be an alternative to IC as first line modality in selected patients with suspected CD. Future studies on implementation in clinical practice are warranted.

CONFLICT OF INTEREST

The Authors declare that there is no conflict of interest.

Supporting information

Supporting Information S1

Supporting Information S2

ACKNOWLEDGMENTS

This work was supported by Public grants from the Region of Southern Denmark and Research council Lillebaelt Hospital. Further support was granted from the Danish Colitis and Crohn's association (CCF) to cover travel expenses of the participants.

Brodersen JB, Knudsen T, Kjeldsen J, Juel MA, Rafaelsen SR, Jensen MD. Diagnostic accuracy of pan‐enteric capsule endoscopy and magnetic resonance enterocolonography in suspected Crohn's disease. United European Gastroenterol J. 2022;10(9):973–82. 10.1002/ueg2.12307

DATA AVAILABILITY STATEMENT

The data that support the findings of this study are available on request from the corresponding author. The data are not publicly available due to privacy or ethical restrictions.

REFERENCES

  • 1. Torres J, Mehandru S, Colombel JF, Peyrin‐Biroulet L. Crohn's disease. Lancet. 2017;389(10080):1741–55. 10.1016/s0140-6736(16)31711-1 [DOI] [PubMed] [Google Scholar]
  • 2. Maaser C, Sturm A, Vavricka SR, Kucharzik T, Fiorino G, Annese V, et al. ECCO‐ESGAR Guideline for Diagnostic Assessment in IBD Part 1: initial diagnosis, monitoring of known IBD, detection of complications. J Crohn's Colitis. 2018;13(2):144–164K. 10.1093/ecco-jcc/jjy113 [DOI] [PubMed] [Google Scholar]
  • 3. Benitez JM, Meuwis MA, Reenaers C, Van Kemseke C, Meunier P, Louis E. Role of endoscopy, cross‐sectional imaging and biomarkers in Crohn's disease monitoring. Gut. 2013;62(12):1806–16. 10.1136/gutjnl-2012-303957 [DOI] [PubMed] [Google Scholar]
  • 4. Kothari ST, Huang RJ, Shaukat A, Agrawal D, Buxbaum JL, Abbas Fehmi SM, et al. ASGE review of adverse events in colonoscopy. Gastrointest Endosc. 2019;90(6):863–76.e33. 10.1016/j.gie.2019.07.033 [DOI] [PubMed] [Google Scholar]
  • 5. Steffenssen MW, Al‐Najami I, Baatrup G. Patient‐reported minor adverse events after colonoscopy: a systematic review. Acta Oncol. 2019;58(Suppl. 1):S22–S28. 10.1080/0284186x.2019.1574979 [DOI] [PubMed] [Google Scholar]
  • 6. Jensen MD, Nathan T, Rafaelsen SR, Kjeldsen J. Diagnostic accuracy of capsule endoscopy for small bowel Crohn's disease is superior to that of MR enterography or CT enterography. Clin Gastroenterol Hepatol. 2011;9(2):124–9. 10.1016/j.cgh.2010.10.019 [DOI] [PubMed] [Google Scholar]
  • 7. Taylor SA, Mallett S, Bhatnagar G, Baldwin‐Cleland R, Bloom S, Gupta A, et al. Diagnostic accuracy of magnetic resonance enterography and small bowel ultrasound for the extent and activity of newly diagnosed and relapsed Crohn's disease (METRIC): a multicentre trial. Lancet Gastroenterol Hepatol. 2018;3(8):548–58. 10.1016/s2468-1253(18)30161-4 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 8. Kopylov U, Yung DE, Engel T, Vijayan S, Har‐Noy O, Katz L, et al. Diagnostic yield of capsule endoscopy versus magnetic resonance enterography and small bowel contrast ultrasound in the evaluation of small bowel Crohn's disease: systematic review and meta‐analysis. Dig Liver Dis. 2017;49(8):854–63. 10.1016/j.dld.2017.04.013 [DOI] [PubMed] [Google Scholar]
  • 9. Hordonneau C, Buisson A, Scanzi J, Goutorbe F, Pereira B, Borderon C, et al. Diffusion‐weighted magnetic resonance imaging in ileocolonic Crohn's disease: validation of quantitative index of activity. Am J Gastroenterol. 2014;109(1):89–98. 10.1038/ajg.2013.385 [DOI] [PubMed] [Google Scholar]
  • 10. Rimola J, Rodriguez S, Garcia‐Bosch O, Ordas I, Ayala E, Aceituno M, et al. Magnetic resonance for assessment of disease activity and severity in ileocolonic Crohn's disease. Gut. 2009;58(8):1113–20. 10.1136/gut.2008.167957 [DOI] [PubMed] [Google Scholar]
  • 11. D'Haens G, Lowenberg M, Samaan MA, Franchimont D, Ponsioen C, van den Brink GR, et al. Safety and feasibility of using the second‐generation Pillcam colon capsule to assess active colonic Crohn's disease. Clin Gastroenterol Hepatol. 2015;13(8):1480–6.e3. 10.1016/j.cgh.2015.01.031 [DOI] [PubMed] [Google Scholar]
  • 12. Leighton JA, Helper DJ, Gralnek IM, Dotan I, Fernandez‐Urien I, Lahat A, et al. Comparing diagnostic yield of a novel pan‐enteric video capsule endoscope with ileocolonoscopy in patients with active Crohn's disease: a feasibility study. Gastrointest Endosc. 2017;85(1):196–205.e1. 10.1016/j.gie.2016.09.009 [DOI] [PubMed] [Google Scholar]
  • 13. Bruining DH, Oliva S, Fleisher MR, Fischer M, Fletcher JG. Panenteric capsule endoscopy versus ileocolonoscopy plus magnetic resonance enterography in Crohn's disease: a multicentre, prospective study. BMJ Open Gastroenterol. 2020;7(1):e000365. 10.1136/bmjgast-2019-000365 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 14. Bossuyt PM, Reitsma JB, Bruns DE, Gatsonis CA, Glasziou PP, Irwig L, et al. STARD 2015: an updated list of essential items for reporting diagnostic accuracy studies. Bmj. 2015;351:h5527. 10.1136/bmj.h5527 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 15. Mow WS, Lo SK, Targan SR, Dubinsky MC, Treyzon L, Abreu‐Martin MT, et al. Initial experience with wireless capsule enteroscopy in the diagnosis and management of inflammatory bowel disease. Clin Gastroenterol Hepatol. 2004;2(1):31–40. 10.1016/s1542-3565(03)00289-1 [DOI] [PubMed] [Google Scholar]
  • 16. Kucharzik T, Tielbeek J, Carter D, Taylor SA, Tolan D, Wilkens R, et al. ECCO‐ESGAR topical review on optimizing reporting for cross‐sectional imaging in IBD. J Crohns Colitis. 2021. [DOI] [PubMed] [Google Scholar]
  • 17. Ordás I, Rimola J, Alfaro I, Rodriguez S, Castro‐Poceiro J, Ramirez‐Morros A, et al. Development and validation of a simplified magnetic resonance index of activity for Crohn's disease. Gastroenterology. 2019;157(2):432–9.e1. 10.1053/j.gastro.2019.03.051 [DOI] [PubMed] [Google Scholar]
  • 18. Spada C, Hassan C, Galmiche JP, Neuhaus H, Dumonceau J, Adler S, et al. Colon capsule endoscopy: European society of gastrointestinal endoscopy (ESGE) guideline. Endoscopy. 2012;44(05):527–36. 10.1055/s-0031-1291717 [DOI] [PubMed] [Google Scholar]
  • 19. Daperno M, D'Haens G, Van Assche G, Baert F, Bulois P, Maunoury V, et al. Development and validation of a new, simplified endoscopic activity score for Crohn's disease: the SES‐CD. Gastrointest Endosc. 2004;60(4):505–12. 10.1016/s0016-5107(04)01878-4 [DOI] [PubMed] [Google Scholar]
  • 20. Gralnek IM, Defranchis R, Seidman E, Leighton JA, Legnani P, Lewis BS. Development of a capsule endoscopy scoring index for small bowel mucosal inflammatory change. Aliment Pharmacol Ther. 2008;27(2):146–54. 10.1111/j.1365-2036.2007.03556.x [DOI] [PubMed] [Google Scholar]
  • 21. Harris PA, Taylor R, Thielke R, Payne J, Gonzalez N, Conde JG. Research electronic data capture (REDCap)–a metadata‐driven methodology and workflow process for providing translational research informatics support. J Biomed Inform. 2009;42(2):377–81. 10.1016/j.jbi.2008.08.010 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 22. Flahault A, Cadilhac M, Thomas G. Sample size calculation should be performed for design accuracy in diagnostic test studies. J Clin Epidemiol. 2005;58(8):859–62. 10.1016/j.jclinepi.2004.12.009 [DOI] [PubMed] [Google Scholar]
  • 23. Hawass NE. Comparing the sensitivities and specificities of two diagnostic procedures performed on the same group of patients. Br J Radiol. 1997;70(832):360–6. 10.1259/bjr.70.832.9166071 [DOI] [PubMed] [Google Scholar]
  • 24. Fagerland MW, Lydersen S, Laake P. The McNemar test for binary matched‐pairs data: mid‐p and asymptotic are better than exact conditional. BMC Med Res Methodol. 2013;13(1):91. 10.1186/1471-2288-13-91 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 25. Burisch J, Kiudelis G, Kupcinskas L, Kievit HAL, Andersen KW, Andersen V, et al. Natural disease course of Crohn’s disease during the first 5 years after diagnosis in a European population‐based inception cohort: an Epi‐IBD study. Gut. 2019;68(3):423–33. 10.1136/gutjnl-2017-315568 [DOI] [PubMed] [Google Scholar]
  • 26. Hyun SB, Kitazume Y, Nagahori M, Toriihara A, Fujii T, Tsuchiya K, et al. Magnetic resonance enterocolonography is useful for simultaneous evaluation of small and large intestinal lesions in Crohn's disease. Inflamm Bowel Dis. 2011;17(5):1063–72. 10.1002/ibd.21510 [DOI] [PubMed] [Google Scholar]
  • 27. Eliakim R, Spada C, Lapidus A, Eyal I, Pecere S, Fernandez‐Urien I, et al. Evaluation of a new pan‐enteric video capsule endoscopy system in patients with suspected or established inflammatory bowel disease ‐ feasibility study. Endosc Int Open. 2018;6(10):E1235–e1246. 10.1055/a-0677-170 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 28. Jeong SH, Lee KJ, Kim YB, Kwon HC, Sin SJ, Chung JY. Diagnostic value of terminal ileum intubation during colonoscopy. J Gastroenterol Hepatol. 2008;23(1):51–5. 10.1111/j.1440-1746.2007.05151.x [DOI] [PubMed] [Google Scholar]
  • 29. Oliva S, Cucchiara S, Civitelli F, Casciani E, Di Nardo G, Hassan C, et al. Colon capsule endoscopy compared with other modalities in the evaluation of pediatric Crohn's disease of the small bowel and colon. Gastrointest Endosc. 2016;83(5):975–83. 10.1016/j.gie.2015.08.070 [DOI] [PubMed] [Google Scholar]
  • 30. Singhal S, Nigar S, Paleti V, Lane D, Duddempudi S. Bowel preparation regimens for colon capsule endoscopy: a review. Therap Adv Gastroenterol. 2014;7(3):115–22. 10.1177/1756283x13504730 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 31. Lobo A, Torrejon Torres R, McAlindon M, Panter S, Leonard C, van Lent N, et al. Economic analysis of the adoption of capsule endoscopy within the British NHS. Int J Qual Health Care. 2020;32(5):332–41. 10.1093/intqhc/mzaa039 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 32. Eliakim R, Yablecovitch D, Lahat A, Ungar B, Shachar E, Carter D, et al. A novel PillCam Crohn's capsule score (Eliakim score) for quantification of mucosal inflammation in Crohn's disease. United European Gastroenterol J. 2020;8(5):544–51. 10.1177/2050640620913368 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 33. Bhatnagar G, Mallett S, Quinn L, Beable R, Bungay H, Betts M, et al. Interobserver variation in the interpretation of magnetic resonance enterography in Crohn's disease. Br J Radiol. 2022;95(1134):20210995. 10.1259/bjr.20210995 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 34. Herrerias JM, Leighton JA, Costamagna G, Infantolino A, Eliakim R, Fischer D, et al. Agile patency system eliminates risk of capsule retention in patients with known intestinal strictures who undergo capsule endoscopy. Gastrointest Endosc. 2008;67(6):902–9. 10.1016/j.gie.2007.10.063 [DOI] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

Supporting Information S1

Supporting Information S2

Data Availability Statement

The data that support the findings of this study are available on request from the corresponding author. The data are not publicly available due to privacy or ethical restrictions.


Articles from United European Gastroenterology Journal are provided here courtesy of Wiley

RESOURCES