An 80-year-old woman presented to our emergency room with jaundice, nausea, and vomiting. An abdominal tomography revealed intrahepatic biliary ducts and common bile duct (CBD) dilation because of an inhomogeneous hypoechoic mass of 2 × 1.5 cm in its distal part and an absence of distant metastases. After a multidisciplinary case discussion it was decided to perform an endoscopic ultrasound-guided fine needle biopsy (EUS-FNB) of the mass and drainage of the CBD.
With a linear echoendoscope (GF-UCT 180; Olympus, Tokyo, Japan), we observed an 18 × 20-mm hypoechoic lesion infiltrating the biliary tract responsible for an upstream dilation of the CBD up to 22 mm. A 22-gauge fine-needle-biopsy needle (Acquire Endoscopic Biopsy Device, Boston Scientific, Marlborough, Massachusetts, USA) was used to perform a biopsy with macroscopic on-site evaluation of the specimen 1 . Histology revealed a cholangiocarcinoma.
An endoscopic retrograde cholangiopancreatography (ERCP) was unsuccessful. We decided to perform an EUS-guided choledochoduodenostomy using an electrocautery-enhanced lumen-apposing metal stent (LAMS) (8 × 20-mm Hot SPAXUS; Taewoong Medical, Gyeonggi‐do, South Korea) from the duodenal bulb with the intrachannel release of the proximal flange ( Fig. 1 ) 2 . An efficient bile flow was immediately observed through the stent. However, the proximal flange was released transpylorically into the stomach, covering the pylorus completely. With a gastroscope with a preloaded smooth cap, we gently pushed the proximal flange through the pylorus into the duodenal bulb, replacing the proximal flange inside the duodenum ( Fig. 2, Video 1 ).
Fig. 1.

Ultrasonographic view of the lesion. a Hypoechoic lesion infiltrating the biliary tract. b Dilated bile duct. c Endoscopic ultrasound-guided choledochoduodenostomy.
Fig. 2.

Endoscopic view of the lumen-apposing metal stent (LAMS). d Transpyloric release of the metal stent into the stomach. e Proximal flange pushed through the pylorus. f The LAMS pushed into the duodenal bulb.
Video 1 Endoscopic ultrasound-guided choledochoduodenostomy with pyloric occlusion by the proximal flange of an electrocautery-enhanced lumen-apposing metal stent: how to solve a rare adverse event.
This is a possible complication that can be encountered during EUS-guided drainage, especially if the proximal flange release is performed inside the operative channel of the scope. A soft electrocautery-enhanced LAMS, such as the Hot SPAXUS 3 , allows easy management of this rare adverse event 4 5 .
Endoscopy_UCTN_Code_TTT_1AS_2AG
Footnotes
Competing interests The authors declare that they have no conflict of interest.
Endoscopy E-Videos : https://eref.thieme.de/e-videos .
Endoscopy E-Videos is an open access online section, reporting on interesting cases and new techniques in gastroenterological endoscopy. All papers include a high quality video and all contributions are freely accessible online. Processing charges apply (currently EUR 375), discounts and wavers acc. to HINARI are available. This section has its own submission website at https://mc.manuscriptcentral.com/e-videos
References
- 1.Mangiavillano B, Frazzoni L, Togliani T et al. Macroscopic on-site evaluation (MOSE) of specimens from solid lesions acquired during EUS-FNB: multicenter study and comparison between needle gauges. Endosc Int Open. 2021;9:E901–E906. doi: 10.1055/a-1395-7129. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 2.Yoo H W, Moon J H, Jo S J et al. A novel electrocautery-enhanced delivery system for one-step endoscopic ultrasound-guided drainage of the gallbladder and bile duct using a lumen-apposing metal stent: a feasibility study. Endoscopy. 2021;53:922–926. doi: 10.1055/a-1301-1526. [DOI] [PubMed] [Google Scholar]
- 3.Mangiavillano B, Moon J H, Crinò S F et al. Safety and efficacy of a novel electrocautery-enhanced lumen-apposing metal stent in interventional EUS procedures (with video) Gastrointest Endosc. 2022;95:115–122. doi: 10.1016/j.gie.2021.07.021. [DOI] [PubMed] [Google Scholar]
- 4.Amato A, Sinagra E, Celsa C et al. Efficacy of lumen-apposing metal stents or self-expandable metal stents for endoscopic ultrasound-guided choledochoduodenostomy: a systematic review and meta-analysis. Endoscopy. 2021;53:1037–1047. doi: 10.1055/a-1324-7919. [DOI] [PubMed] [Google Scholar]
- 5.Teoh A YB, Kongkam P, Bapaye A et al. Use of a novel lumen apposing metallic stent for drainage of the bile duct and gallbladder: long term outcomes of a prospective international trial. Dig Endosc. 2021;33:1139–1145. doi: 10.1111/den.13911. [DOI] [PubMed] [Google Scholar]