Abstract
Electronic medication management (eMM) systems are designed to improve safety, but there is little evidence of their effectiveness in paediatrics. This study assesses the short-term (first 70 days of eMM use) and long-term (one-year) effectiveness of an eMM system to reduce prescribing errors, and their potential and actual harm. We use a stepped-wedge cluster randomised controlled trial (SWCRCT) at a paediatric referral hospital, with eight clusters randomised for eMM implementation. We assess long-term effects from an additional random sample of medication orders one-year post-eMM. In the SWCRCT, errors that are potential adverse drug events (ADEs) are assessed for actual harm. The study comprises 35,260 medication orders for 4821 patients. Results show no significant change in overall prescribing error rates in the first 70 days of eMM use (incident rate ratio [IRR] 1.05 [95%CI 0.92–1.21], but a 62% increase (IRR 1.62 [95%CI 1.28–2.04]) in potential ADEs suggesting immediate risks to safety. One-year post-eMM, errors decline by 36% (IRR 0.64 [95%CI 0.56–0.72]) and high-risk medication errors decrease by 33% (IRR 0.67 [95%CI 0.51–0.88]) compared to pre-eMM. In all periods, dose error rates are more than double that of other error types. Few errors are associated with actual harm, but 71% [95%CI 50–86%] of patients with harm experienced a dose error. In the short-term, eMM implementation shows no improvement in error rates, and an increase in some errors. A year after eMM error rates significantly decline suggesting long-term benefits. eMM optimisation should focus on reducing dose errors due to their high frequency and capacity to cause harm.
Subject terms: Paediatrics, Risk factors
Introduction
Medication errors are a recognised persistent problem in paediatrics1. Information technologies including electronic medication management systems (eMM, also known as e-prescribing or Computerised Provider Order Entry [CPOE]) have been advanced to reduce medication errors in this population2–4. Multiple studies of eMM use and its effects in adult hospitals have been conducted5, with a recent systematic review finding nine of 10 studies reported a significant reduction in prescribing error rates5. However, reviews on this topic persistently report marked inconsistencies in study quality, error definitions and denominators5–7. Few studies have investigated the effects of this technology in paediatric hospitals1.
Prescribing in children is complex as decisions often require information about weight, age, dosing ranges and off-label use of medicines, and this increases the risk of medication errors8,9. The consequences of prescribing errors can be significant given children’s physiological and developmental vulnerabilities10. Concerns have been raised that eMM systems have often not been well-adapted to paediatric medication challenges11–14 (e.g., the increased complexity of weight-based dose calculations in children and the absence of detailed paediatric-specific medicines information in the decision support provided). Hence findings from eMM studies in adult hospitals may not be directly extrapolated to paediatric populations.
eMM systems have multiple mechanisms by which they are designed to support safe prescribing and reduce errors. These include: improved legibility of medication orders; structured order sentences for selection and editing; decision support (both passive e.g. online information resources and active e.g. alerts) available at the point of prescribing.
eMM evaluation studies undertaken in paediatrics have largely employed before and after designs, and most have focused on systems used in intensive care5,9,15. The existing limited evidence suggests that eMM may be more effective in reducing only certain error types in paediatrics. For example, Walsh et al.16 found paediatric eMM systems were effective in reducing incomplete/wrong order errors but not dose errors, and a review by Tolley et al.17 identified eMM features which contributed to dose errors in paediatrics. Greater knowledge of these outcomes is needed to inform system design and use. No randomised controlled trials of the effectiveness of eMM to reduce medication errors on general paediatric wards have been conducted, and few studies have attempted to quantify changes in actual harm associated with eMM use1,5,18.
As the adoption of clinical information systems continues worldwide, questions about how best to implement these systems in safe and effective ways remain. The strengths and weaknesses of sequential versus whole of organisation (big bang) roll-outs are advocated with limited evidence to guide decision-making19,20. Feasibility and resource issues will often drive the implementation strategy. eMM evaluation studies have focused on measurement at specific points in time and have provided limited evidence of the temporal impact of systems on medication safety5. Such information would be valuable in identifying both when implementation support is most required and at what point medication safety benefits may be expected.
In this study, we conduct a stepped-wedge cluster randomised controlled trial (SWCRCT) with an additional one-year follow-up to assess the short- and long-term effectiveness of an eMM system to reduce prescribing errors, their potential severity and associated actual harm at a major paediatric referral hospital. We demonstrate no initial benefit from eMM in the first 70-days of use, with increases in some error types posing potentially greater patient risk during this period. Prescribing error rates one-year after eMM significantly decline from pre-eMM rates. Dose errors are the most frequent error type and are most often associated with patient harm. Our findings indicate the need for close attention to support staff in system training and integration of use into clinical work practices, along with monitoring of errors during the first months of system use. Optimisation of paediatric eMM systems should particularly focus on features to reduce dose errors and their effects.
Results
Characteristics of study periods
In total 35,260 medication orders for 4821 patients across all study periods (4509 unique patients) were retrospectively reviewed for errors. Table 1 reports the characteristics of patients and orders.
Table 1.
Control period | Intervention period | ||
---|---|---|---|
Paper | First 70 days of eMM | One-year post-eMM | |
Number of patients | 1686 | 2096 | 1039 |
Number (%) female | 691 (40.98) | 838 (39.98) | 460 (44.27) |
Mean (SD) age, months | 73.9 (62.4) | 88.4 (63.4) | 86.1 (63.5) |
Median (IQR) age, months | 55.5 (18.0–124.8) | 85.0 (27.0–142.0) | 80.0 (26.0–139.0) |
Number of admissions | 1769 | 2298 | 1201 |
Number of patient-days | 5252 | 8384 | 4458 |
Number of orders | 9635 | 16,734 | 8891 |
Number (%) of orders for high-risk medications (see Box 1) | 1200 (12.45) | 2274 (13.59) | 1334 (15.00) |
Changes in prescribing error rates in the short- and long-term post-eMM
Overall, clinical prescribing error rates did not significantly change (IRR 1.05) in the short-term (first 70 days of eMM use), but there was a significant 62% increase (IRR 1.62) in potential ADEs (Table 2). Procedural prescribing errors significantly declined (IRR 0.65) in the short-term (Table 2 and further details available in Supplementary Tables 1 and 2).
Table 2.
Control (Paper) | Intervention (first 70 days of eMM) | IRR (95% CI)a (eMM vs Paper) | P valuea | |
---|---|---|---|---|
All clinical prescribing errors | – | |||
Number of patients | 1686 | 2096 | ||
Number of medication orders | 9635 | 16,734 | ||
Number of clinical prescribing errors | 1399 | 2942 | ||
Error rateb per 100 orders (95% CI) | 14.52 (13.78–15.30) | 17.58 (16.96–18.23) | 1.05 (0.92–1.21) | 0.45 |
Potential ADEs (clinical prescribing errors with a potential severity score ≥3) | ||||
Number of potential ADEs | 353 | 812 | ||
Error rateb per 100 orders (95% CI) | 3.66 (3.30–4.07) | 4.85 (4.53–5.20) | 1.62 (1.28–2.04) | <0.001 |
Clinical prescribing errors involving high-risk medications | ||||
Number of patients with high-risk medication orders | 799 | 1228 | ||
Number of high-risk medication orders | 1200 | 2274 | ||
Number of clinical prescribing errors involving high-risk medications | 232 | 390 | ||
Error rateb per 100 high-risk medication orders (95% CI) | 19.33 (17.00–21.99) | 17.15 (15.53–18.94) | 0.88 (0.66–1.16) | 0.35 |
All procedural errorsc | ||||
Number of patients with procedural errors reviewed | 1162 | 1429 | ||
Number of medication orders | 6698 | 11,441 | ||
Number of procedural errors | 7652 | 7699 | ||
Procedural error rateb per 100 orders (95% CI) | 114.24 (111.71–116.83) | 67.29 (65.81–68.81) | 0.65 (0.61–0.70) | <0.001 |
aAdjusted incidence rate ratio (IRR), 95% CIs and P values from generalised linear mixed models adjusting for patient age, study time, and clustering by ward (unit of randomisation) and patient. ADE is adverse drug event.
bCrude error rates and 95% CIs are from simple Poisson models.
cProcedural errors were assessed from a random sample comprising 68.5% of patients during the entire SWCRCT period. Details of changes in procedural errors by error type are in Supplementary Tables 1 and 2.
One-year post-eMM, clinical prescribing error rates had significantly declined by 36% (IRR 0.64) compared to when paper medication charts (control) were used (Table 3). There was also a 33% reduction in errors associated with high-risk medications between the control and one-year post-eMM (IRR 0.67) (Table 3), and potential ADEs returned to a similar level to the control period.
Table 3.
Control (Paper) | Intervention (one-year post-eMM) | IRR (95% CI)a (one-year post-eMM vs Paper) | P valuea | |
---|---|---|---|---|
All clinical prescribing errors | – | |||
Number of patients | 1686 | 1039 | ||
Number of medication orders | 9635 | 8891 | ||
Number of clinical prescribing errors | 1399 | 1043 | ||
Error rateb per 100 orders (95% CI) | 14.52 (13.78–15.30) | 11.73 (11.04–12.46) | 0.64 (0.56–0.72) | <0.001 |
Potential ADEs (clinical prescribing errors with a potential severity score ≥3) | ||||
Number of potential ADEs | 353 | 299 | ||
Error rateb per 100 orders (95% CI) | 3.66 (3.30–4.07) | 3.36 (3.00–3.77) | 0.93 (0.72–1.19) | 0.55 |
Clinical prescribing errors involving high-risk medications | ||||
Number of patients with high-risk medication orders | 799 | 607 | ||
Number of high-risk medication orders | 1200 | 1334 | ||
Number of clinical prescribing errors involving high-risk medications | 232 | 176 | ||
Error rateb per 100 high-risk medication orders (95% CI) | 19.33 (17.00–21.99) | 13.19 (11.38–15.29) | 0.67 (0.51–0.88) | 0.004 |
aAdjusted incidence rate ratio (IRR), 95% CIs and P values from generalised linear mixed models adjusting for patient age, study time, and clustering by ward (unit of randomisation) and patient. ADE is adverse drug event.
bCrude error rates and 95% CIs are from simple Poisson models.
Changes in types of clinical prescribing errors in the short- and long-term post-eMM
The most frequent types of clinical prescribing errors in all periods were dose, route, frequency and duplicate drug therapy errors, in total making up over 90% of errors in each period (Table 4). Dose errors comprised more than 40% of all clinical prescribing errors in all periods. Overdose error rates were consistently higher in all periods compared to underdose errors (Table 4).
Table 4.
Error type | Control—Paper (n = 9635 orders) | Intervention—First 70 days of eMM (n = 16,734 orders) | Intervention—One-year post-eMM (n = 8891 orders) | |||||
---|---|---|---|---|---|---|---|---|
No. Errors | Errors/100 orders (95% CI)a | No. Errors | Errors/100 orders (95% CI)a | IRRb eMM vs Paper | No. Errors | Errors/100 orders (95% CI)a | IRRb One-year post-eMM vs Paper | |
Wrong dose | 644 | 6.68 (6.19–7.22) | 1288 | 7.70 (7.29–8.13) | 1.22 (1.04–1.43) | 534 | 6.01 (5.52–6.54) | 0.79 (0.68–0.93) |
Overdose | 308 | 3.20 (2.86–3.57) | 674 | 4.03 (3.74–4.34) | 1.22 (0.96–1.55) | 247 | 2.78 (2.45–3.15) | 0.79 (0.63–1.01) |
Underdose | 223 | 2.31 (2.03–2.64) | 408 | 2.44 (2.21–2.69) | 1.25 (0.95–1.66) | 183 | 2.06 (1.78–2.38) | 0.83 (0.64–1.07) |
Wrong frequency | 315 | 3.27 (2.93–3.65) | 522 | 3.12 (2.86–3.40) | 0.92 (0.73–1.16) | 157 | 1.77 (1.51–2.06) | 0.47 (0.36–0.61) |
Wrong route | 199 | 2.07 (1.80–2.37) | 396 | 2.37 (2.14–2.61) | 1.65 (1.20–2.27) | 77 | 0.87 (0.69–1.08) | 0.44 (0.27–0.71) |
Duplicated drug therapy | 140 | 1.45 (1.23–1.71) | 457 | 2.73 (2.49–2.99) | 1.82 (1.26–2.63) | 205 | 2.31 (2.01–2.64) | 1.48 (1.05–2.09) |
Wrong drug | 24 | 0.25 (0.17–0.37) | 62 | 0.37 (0.29–0.48) | 1.82 (0.66–5.00) | 15 | 0.17 (0.10–0.28) | 0.49 (0.11–2.23) |
Drug–drug interaction | 20 | 0.21 (0.13–0.32) | 71 | 0.42 (0.34–0.54) | 0.69 (0.23–2.09) | 17 | 0.19 (0.12–0.31) | 0.39 (0.09–1.73) |
Allergy | 20 | 0.21 (0.13–0.32) | 19 | 0.11 (0.07–0.18) | 0.45 (0.12–1.75) | 13 | 0.15 (0.08–0.25) | 3.17 (0.48–20.9) |
Inadequate monitoring | 19 | 0.20 (0.13–0.31) | 40 | 0.24 (0.18–0.33) | 1.19 (0.34–4.19) | 5 | 0.06 (0.02–0.14) | – |
– indicates too few errors for modelling (Supplementary Table 3 reports remaining error categories).
aCrude error rates and 95% CIs are from simple Poisson models.
bAdjusted incidence rate ratio (IRR) and 95% CIs are from generalised linear mixed models adjusting for study time (immediate post-eMM model only), patient age, and clustering by ward and patient.
In the short-term, rates for three error types increased: wrong dose (IRR 1.22), route (IRR 1.65) and duplicate therapy (IRR 1.82) errors (Table 4) relative to the control period. Wrong frequency errors remained relatively constant during the first 70 days of eMM use.
One-year post-eMM, wrong dose (IRR 0.79), wrong route errors (IRR 0.44) and wrong frequency errors (IRR 0.47) had declined compared to the control period. However, duplicate drug therapy error rates continued to be higher than when paper medication charts (control) were used (IRR 1.48) (Table 4).
Potential ADEs and evidence of error detection by staff
In total 27.2% (1464/5384) of clinical prescribing errors were rated with a potential harm score of ≥3. There was little change in this proportion over the study periods (Table 5).
Table 5.
Potential harma severity | Control—Paper | Intervention—First 70 days of eMM | Intervention—One-year post-eMM | |||
---|---|---|---|---|---|---|
n | % (95% CI) | n | % (95% CI) | n | % (95% CI) | |
1: No/minimal harm | 382 | 27.3% (24.5–30.1) | 797 | 27.1% (25.2–29.1) | 281 | 26.9% (23.7–30.3) |
2: Temporary harm requiring monitoring | 664 | 47.5% (44.7–50.3) | 1333 | 45.3% (43.4–47.3) | 463 | 44.4% (41.1–47.7) |
3: Temporary harm requiring intervention | 299 | 21.4% (18.6–24.2) | 686 | 23.3% (21.4–25.3) | 266 | 25.5% (22.2–28.8) |
4: Permanent harm requiring intervention | 48 | 3.4% (0.6–6.3) | 112 | 3.8% (1.9–5.8) | 28 | 2.7% (0–6.0) |
5: Potential death | 6 | 0.4% (0–3.3) | 14 | 0.5% (0.0–2.5) | 5 | 0.5% (0.0–3.8) |
Total of prescribing errors with a score ≥3 | 353 | 25.2% (23.0–27.6) | 812 | 27.6% (26.0–29.3) | 299 | 28.7% (25.9–31.5) |
aDefinitions provided in Supplementary Table 6. Confidence intervals (CIs) for the potential harm categories are 95% simultaneous multinomial CIs. For the total, CIs are exact (Clopper–Pearson) binomial 95% CIs.
A small proportion of clinical prescribing errors was detected by staff, but this proportion increased significantly with eMM implementation (test of equal proportions χ2 = 29.6, 1 df, p < 0.001). In the control period, 9.3% (95% CI 7.8–10.9) of errors had some evidence of detection. In the short-term, this increased to 15.4% (95% CI 14.1–16.7) and at one-year post-eMM was 17.3% (95% CI 15.0–19.7).
Actual harm associated with clinical prescribing errors in the SWCRCT
In total, 368 errors involving 172 patients were reviewed by the harm assessment panels. For 21 (12.2%) patients with 40 clinical prescribing errors, there was evidence in patients’ records of associated harm. Of these 21 patients, 8 (18 errors) experienced errors resulting in minor harm, 12 (21 errors) moderate and 1 serious harm (1 error). The harm panel rated the likelihood that the harm was caused by the error as possible in 9 cases, probable in 8 cases, and certain in 4 cases. Dose errors were attributed to the actual harm occurring in 71% (15/21; 95% CI 50–86) of patients experiencing harm (control period 8 dose errors/11 patients with harm; first 70 days post-eMM 7 dose errors/10 patients) (Supplementary Table 4). Table 6 reports prescribing errors associated with actual harm by a range of denominators.
Table 6.
Prescribing errors with actual harm | Control—Paper (number of errors with actual harm = 14) | Intervention—First 70 days of eMM (number of errors with actual harm = 26) |
---|---|---|
per 1000 orders | 1.45 [95% CI 0.87–2.44] | 1.55 [95% CI 1.06–2.28] |
per 1000 errors | 10.01 [95% CI 5.97–16.73] | 8.84 [95% CI 6.04–12.92] |
per 1000 patient-days | 2.66 [95% CI 1.59–4.47] | 3.10 [95% CI 2.12–4.54] |
per 100 admissions | 0.79 [95% CI 0.47–1.32] | 1.13 [95% CI 0.77–1.65] |
Denominator numbers are presented in Table 1.
eMM electronic medication management system, CI confidence interval (binomial Wilson method).
Discussion
We aimed to assess the effectiveness of eMM use in paediatrics to reduce prescribing errors both in the short- and long-term. We found that in the short-term there was no significant decrease in overall clinical prescribing error rates (IRR 1.05; 95% CI 0.92–1.21). However, potential ADEs increased by 62% (IRR 1.62; 95% CI 1.28–2.04).
Our one-year follow-up showed a significant 36% reduction (IRR 0.64; 95% CI 0.56–0.72) in overall clinical prescribing errors compared to the paper period. Prescribing errors involving high-risk medications decreased by 33% (IRR 0.67; 95% CI 0.51–0.88) and potential ADEs returned to a rate similar to the control (IRR 0.93; 95% CI 0.72–1.19).
Very limited comparative data are available, with differences in study designs and error definitions and identification processes applied2,5. To date, decision makers have largely relied upon evidence of eMM effectiveness in paediatrics from two studies conducted on general paediatric wards in the United States undertaken between 2006 and 200816,21. One21,22 uncontrolled pre/post study showed a reduction in medication errors post-eMM and the second16 (an interrupted time series study) no change. A further small uncontrolled pre-post 2006 UK study23 reported an increase in prescribing errors 6 months post-eMM.
The time periods over which previous studies have examined effectiveness have also varied. Studies by Barber et al.23 and Walsh et al.16 reported no reduction in medication error rates at 6 and 9 months post-eMM, while Holdsworth et al.21 found significant reductions at around 15 months post-eMM. While these studies provide a small comparative evidence-base, together with our findings they are broadly consistent in demonstrating that beneficial effects of eMM on prescribing may not be apparent for a period of around 12 months. This provides a useful time parameter to inform future studies regarding when post-implementation assessments should be considered and when benefits may be likely to commence.
To understand the experiences of clinical staff during the implementation and early stages of eMM use, in parallel with the SWCRCT, we conducted 122 short interviews with doctors and nurses on all wards 1, 3, 6 and 26 weeks post-eMM24. Inexperience with system use and issues with system usability, functionality and accessibility were frequently reported in the immediate weeks following implementation, with clinicians suggesting that these factors contributed to delayed medication delivery and reduced medication safety24. Dealing with hybrid paper and computer medication systems was also identified as problematic. These themes were generic across wards during the early weeks of system use and are factors which assist in explaining the failure of prescribing errors to decrease in the immediate post-eMM period.
Interview findings demonstrated that issues raised by staff changed over time24. Six months post-eMM, many initial problems reported by staff (e.g. inexperience with use) were no longer mentioned. At 6-months post-eMM new themes emerged with clinicians increasingly reporting that the system was making a positive contribution to medication safety, consistent with the changes in error rates observed longer term. However, new issues also became apparent, including concerns about new types of errors, e.g. drop-down menu selection errors, associated with system use17,25. Some of these technology-related errors may decrease as users become more familiar with the system and identify ways to work around system limitations. Thus, a reduction in these technology-related errors following increased eMM system familiarity may also have contributed to both the lack of change in prescribing error rates in the short-term and the later observed reduction in error rates one-year post-eMM.
An important new finding was evidence of an increase in some categories of high-volume clinical prescribing errors during the first 70 days of eMM use. Four error types accounted for over 90% of all errors in each study period, and rates for three of these common error types increased in the short-term. These results suggest the eMM system had generalised effects on prescribing, consistent with users’ initial unfamiliarity and inexperience with system use, and broad disruptions to workflows26, all of which were reported by users in the early weeks of system use24.
Training was mandatory for staff in order to use the system and was provided close to the time of implementation. Yet many still reported considerable challenges in system use. This situation is likely a reflection of the differences between using a system in a training situation compared to a real-world setting where contextual factors such as time pressures, interruptions and integration with other related work practices come into operation. It is very difficult to mimic these real-world work demands and pressures within a system training environment. These findings re-emphasise the importance of high levels of support, training and close monitoring during the first several months of use.
One-year post-eMM, reductions in three of the four common paediatric prescribing errors had occurred. These reductions suggest that, in the longer term, with users’ increased familiarity with the system, the core functionality of eMM (e.g. the ability to select from standardised order sentences, legibility of all orders, decision support such as dose guidance) contributed to reduced prescribing errors. Duplicate drug therapy errors increased in the short-term post-eMM and remained higher one-year post-eMM. A doubling of duplicate therapy errors was identified in a recent before and after study of eMM in a paediatric intensive care unit in Ireland27. Feedback from our study pharmacists indicated a likely contributing factor was that clinicians seeking to correct an order in the eMM would type a new order but then fail to cease the original order, leading to duplicate orders being active. Hybrid paper-eMM situations also contributed to duplicate therapy errors, with some orders appearing both on paper and electronic charts during the implementation period. Some medications remained on separate paper charts, for example sliding scale insulin orders and some specialised pain medications, and these are likely to have contributed to duplicate drug therapy errors in the longer term. These error types should be amenable to improvement by reducing hybrid systems, alerting users via training, and system design enhancements.
Wrong dose errors are the most concerning type of error, given their high frequency and potential for harm. Dose errors, including 10-fold dose errors27,28, have consistently been identified as problematic in paediatrics, despite the introduction of eMM9,14,16,27,28. Reasons include the complexity of dose calculations for paediatrics and the sometimes limited guidance available to clinicians regarding medication use in children with specific conditions.
These findings indicate that a key focus for optimisation of eMM should be reducing dose errors. System features which provide support and guidance for prescribers, such as indication-dose alerts, weight-based filtering of order sentences, alerts to indicate major variations in patient weight that may result in dosing errors, and dose-weight calculators should be considered17,29. Such efforts to reduce dose errors are likely to bring the most benefit to reducing the risk of patient harm, in tandem with education in safe paediatric prescribing principles8,30. Further investigation of the mechanisms by which prescribing errors occur when an eMM is used can be particularly helpful in identifying design feature changes or tips for users in order to avoid common errors. To share this knowledge more widely as it becomes available, an outcome from this study is the publication of the Health Innovation Series on eMedication Safety31 which provides one-page evidence-based recommendations for system optimisation and user tips.
Overall, we found a low rate of prescribing errors associated with actual harm. Harm rates in the control and intervention periods were similar. However, among patients with errors resulting in actual harm, most cases (71%) involved dose errors (both with paper prescribing 73% and in the first 70 days post-eMM 70%).
Few studies have assessed actual harm associated with medication errors. Holdsworth et al.21 compared harm associated with multiple types of medication errors (including administration errors) occurring in paediatric wards and intensive care units. They reported a change in errors causing harm from 3.8/100 admissions to 2.2/100 post-eMM, considerably higher than found in our study (0.79/100 admissions pre and 1.13 post). A limitation of our study was that our harm identification relied upon retrospective record reviews. In contrast, Holdsworth et al.21 conducted prospective record reviews and interviews with staff close in time to when errors occurred. This enabled the capture of information which may never be recorded in patients’ records. Thus, our rates of prescribing errors causing actual harm are likely to be an underestimate of the true rate.
For over 80% of all clinical prescribing errors identified in our retrospective record audits there was no evidence that errors had been detected by staff. Thus, specific actions, such as monitoring or testing for signs or symptoms indicative of adverse effects, rarely occurred. An absence of investigations and monitoring information, which might provide clues as to possible adverse effects, limited the capacity of our panels to identify harm. An absence of documented evidence was generally equated to be an absence of adverse effects by our clinical harm panels. The clinical complexity of cases reviewed was also noted to be generally very high and abstracting the potential consequences of an error for children with complicated clinical presentations who were on a range of medications was often difficult for the panel. These challenges should be considered by future researchers embarking upon this process. Due to resource constraints, we did not conduct harm panels one-year post-eMM and so cannot determine whether errors associated with harm decreased in the long-term.
The SWCRCT design with one-year follow-up allowed a rigorous evaluation of the effectiveness of the eMM system to reduce prescribing errors. The 12-month follow-up study was an uncontrolled pre-post assessment. The research team had close and ongoing consultation with the hospital during the entire study and no significant medication safety interventions were instituted during this time period. However, we cannot rule out other factors that may have contributed to the reduction in error rates seen at the one-year follow-up. The study was limited to a specialist paediatric hospital, and so generalisability to other sites is unclear. Retrospective prescribing error harm assessments were limited by the level and quality of medical record documentation.
Our findings demonstrated no initial benefit from eMM in the first 70-days of use and suggest measurable risks to patient safety in this period due to increases in potentially harmful prescribing errors. Thus, close attention to support staff in training and integration of system use into clinical work practices, along with monitoring of errors during the first few months of system use should be a priority. One year later, prescribing error rates had significantly declined. Future optimisation of paediatric eMM systems should focus on features to reduce dose errors due to their high frequency and greater capacity to cause harm in this population.
Methods
Study design and setting
A SWCRCT with an additional one-year follow-up was undertaken at a 310-bed major urban paediatric tertiary referral hospital, one of two such hospitals serving the 8.2 million population of New South Wales, Australia32.
A SWCRCT design was selected as it was not feasible to undertake individual patient randomisation. As the hospital had decided to implement the eMM across the hospital, there was no option of conducting a cluster randomised controlled trial (CRCT) where only some wards would be randomised to receive the intervention with others randomised to remain using paper medication charts. Given that wards treat different types of patients, such a CRCT would also introduce a bias when comparing intervention and control wards. A SWCRCT design allows clusters to be their own controls and thus data generated from both control and intervention periods can be compared, and hence reduce bias33. The SWCRCT, conducted over a period of 11 weeks (Fig. 1), allowed comparison of prescribing errors occurring in the control period (when paper medication charts were used) with those occurring when the eMM was implemented (intervention period). The SWCRCT allowed assessment of the short-term effects of the intervention on prescribing error rates during this first 70 days of eMM use at the hospital.
All inpatients during the study periods were included, except those in oncology and intensive care units, as the hospital determined that eMM implementation was not possible on these wards as part of the SWCRCT.
Nine wards were grouped into eight clusters prior to randomisation. Two wards were randomised together as there was direct physical access from one ward to the other, and they treated similar patients. Researchers, blinded to cluster/ward identity and independent of the hospital, randomly assigned (using a computer number generator) the sequence of cluster eMM implementation. The trial had 11 steps of one-week duration (Fig. 1). The hospital determined the one-week step between cluster implementations. Patients could be in different steps and/or clusters due to ward transfers or readmissions.
Following the publication of the trial protocol32, additional data were collected one-year post-eMM implementation to allow comparison of prescribing error rates between the control period and one-year post-eMM.
Medication administration error data were collected using direct observation during the SWCRCT and will be reported in a separate publication, as will the impact of eMM on patient length of stay. The second planned hospital site was not able to participate in a SWCRCT as originally planned in the protocol due to changes to the implementation plan by the hospital.
The trial was registered with the Australian New Zealand Clinical Trials Registry (ANZCTR) 370325. Registered 17 October 2016, and received ethical approval from the Sydney Children’s Hospital Network Human Research Ethics Committee (HREC/15/SCHN/370). Individual patient consent to access retrospective medication and clinical records was waived.
The control and intervention
In the control period, medication orders were hand-written on paper charts. During the SWCRCT, clusters sequentially implemented the eMM. The intervention was an eMM module added to the hospital’s existing clinical information system (Cerner Corporation). The eMM allows electronic prescribing, recording of drug dispensing, drug administration and medication reconciliation and monitoring. The eMM contained passive and active decision support, e.g. guidelines, policies, protocols, order-sets, order sentences, dose-range limits, therapeutic drug monitoring and related pathology parameters, drug–drug interaction alerts, and dosage calculators. All wards had access to the same decision support. Specialised pain management prescribing remained on paper, as did sliding scale insulin and insulin pump orders.
The hospital organised an extensive staff training programme, in how to use the eMM system, which prescribers were required to complete. Training was provided for staff on each ward two weeks prior to implementation, adopting a “just in time” training approach. Multiple online resources were made available to assist with specific processes34. Training was classroom-based with further self-directed modules. Junior medical officers, who complete the majority of prescribing tasks, were required to demonstrate competency during the class via workbook exercises and only then allowed access to the system. Further, during the implementation, support staff were available on individual wards to assist with implementation and trouble-shooting. On the first day of implementation on each ward, paper medication charts were copied to the eMM system. All new patients entering the ward from that time onwards were entered into the eMM system. If patients were transferred to a ward without the eMM system, their medications would be transferred to a paper medication chart. Once the ward implemented the eMM, it was mandatory for staff to prescribe medications using the system. If an order was not placed in the system, the pharmacy could not dispense and a nurse could not administer the medication. All paper prescription pads and paper medication charts were removed from the wards. Downtime medication charts were available in the event of a downtime, but these were stored separately.
Prescribing error data collection
Medication orders for inpatients in all study periods (April–July 2016; June–September 2017) were reviewed retrospectively by one of three clinical pharmacists, independent from the hospital, to identify and classify clinical and procedural prescribing errors35 (Supplementary Table 5). The order in which records were reviewed was randomised across all wards. All errors identified by the pharmacists were rated for their potential harm severity (to identify potential adverse drug events [ADEs]) using a five-point scale based on an adapted version of the NCC MERP Index for categorizing medication errors36 (Supplementary Table 6). Any documentation which indicated that staff had detected an error (e.g. note of an order correction; a case conference with parents) was recorded. Details of all medications ordered (date of prescribing, medication name and route) for each patient admission were recorded to provide denominators for error rate calculations.
Interim analysis of procedural errors was conducted after medication charts of 2000 admissions had been audited. Collection of procedural errors ceased because of the high frequency and time taken to record these errors. In total, procedural prescribing errors were collected for a random sample of 2591 patients (18,139 medication orders), which accounted for 68.5% of patients across the entire 11-week SWCRCT. Procedural errors were not collected during the one-year follow-up.
A random stratified sample of patient records in the eight clusters was obtained one year from the date of last cluster implementation (between 20 June 2017 and 20 September 2017). Stratification was conducted by cluster/ward. Number of patients for each ward was decided based on the distribution of patients admitted in study wards. Hence the number per ward was different. Patients were then randomly selected using a random number generation code (SAS).
Training and inter-rater reliability assessment
The prescribing error definitions and detailed guidelines for how to review records and classify errors were developed based upon an existing error classification applied in studies in adult hospitals by the research team35. This classification was modified to account for differences in paediatric prescribing informed by hospital prescribing guidelines (Supplementary Table 5).
Training in the use of the error classification involved pharmacist reviewers applying the classification to the same subsets of patient records and then meeting to discuss any differences in outcomes. Once training was complete, inter-rater reliability between the three pharmacist reviewers (the most experienced, selected as the gold standard) was conducted to ensure all reviewers had good agreement in classifying prescribing errors and potential severity of those errors. The pharmacist reviewers obtained a minimum Cohen’s kappa score of 0.77 on error type and 0.76 on severity level before they commenced independent data collection. The second round of inter-rater reliability was conducted a year later (minimum kappa 0.95 and 1.0, respectively).
Assessing actual harm associated with clinical prescribing errors
A multi-disciplinary harm assessment panel (comprising a paediatrician, paediatric nurse and pharmacist and/or clinical pharmacologist) met on 12 occasions to determine actual harm associated with errors (i.e. actual ADEs). The medical records of patients with errors with a potential harm severity score of ≥3 were reviewed by clinically trained members of the research team, prior to cases being referred to the harm panel, to exclude errors not administered to patients (e.g. order with dose error that was not administered; or duplicate orders not administered).
Detailed case reports (outlining a patient’s medical history, prescribing errors, other medications, signs and symptoms, changes to treatment/care before and after the error, and relevant test results) were prepared by clinically trained members of the research team. The harm panel members each reviewed the cases individually, and then met to gain consensus about any actual harms and the severity. Some patients experienced multiple errors (Supplementary Table 3). Where harm was identified, the severity was classified using the Harm Associated with Medication Error Classification (HAMEC)37 and the probability that the error caused the harm was classified using a modified version of the WHO Uppsala Monitoring Centre categories38 (Supplementary Tables 7 and 8). Overall, this was a laborious process which commenced in 2019, and completed in 2021. Reduced access to clinicians for the panels due to the pandemic slowed progress.
Sample size calculations
As outlined in our protocol, the expected reduction in overall prescribing error rate was 60%, from 4.06 errors per admission (SD = 5.27) to 1.62 (SD = 2.87) with an estimated intraclass correlation coefficient (ICC) of 0.06. Collecting data on eight clusters would allow detection of a minimum change of 20% for overall errors with 100% power and 42% change for potential ADEs with 83% power (for two-sided tests; α < 5%). At each step, records for 112 patient admissions were estimated to be required, totalling 1232 across the study.
The one-year follow-up sample size was calculated based on data from 1817 patients generated during the SWCRCT. Using these data, we calculated a clinical prescribing error rate of 0.24/patient-day (SD = 0.78) with an ICC of 0.04 for eight clusters. To detect a 35% change one-year post-eMM, we required 1230 patient records for the one-year post-eMM follow-up sample (for a two-sided test; 80% power; α < 5%).
Analysis
The study involved comparison of error rates for three periods: (1) Control, when prescribing occurred on paper medication charts during the SWCRCT; (2) Intervention, first 70 days of eMM use measured during the SWCRCT; and (3) one-year post-eMM, when prescribing using the eMM had been in place for one year on all wards. Outcome measures are listed in Box 1.
We applied an intention to treat analysis, with all orders analysed according to whether the ward was using eMM or paper medication charts. Crude error rates per 100 orders with 95% confidence intervals (CIs) were estimated from simple Poisson models. Errors per 100 orders in the SWCRCT, i.e. control and intervention periods, were modelled using generalised linear mixed-effects negative binomial models accounting for the stepped-wedge design39,40. The dependent variable was the number of errors per patient-day, with an offset of the logarithm of the number of orders per patient-day. Random effects terms were included for cluster (unit of randomisation) and patient (to account for admissions over multiple days). As observations for each day were available, we modelled the secular trend as continuous using restricted cubic splines with 4 degrees of freedom40,41. As the average patient age was younger in the paper period (because of the order of eMM rollout to wards with different patient profiles), we adjusted for age in months as a restricted cubic spline with 2 degrees of freedom (Supplementary Table 9). We used splines for the secular trend and patient age to avoid assuming linear associations with errors. Knots were placed at recommended quantiles of the variables41. An indicator variable was included for eMM vs paper. This model assumes a constant effect of the intervention throughout the study period and across all clusters. From the models, we estimated incidence rate ratios (IRRs) for eMM use (intervention) vs paper (control). We used similar models without the secular trend to estimate IRRs for one-year post-eMM vs paper. Clinical and procedural errors were modelled separately, with additional models for errors with potential severity score ≥3 (i.e. potential ADE) and for orders involving high-risk drugs. To model rates of individual error types, we used the same model specifications used for the main results, but with Poisson instead of negative binomial distribution as there was no overdispersion at this level and negative binomial models failed to converge.
We used a χ2 test to assess any difference in the proportion of errors detected by staff in the paper and eMM periods. Data management was performed in SAS version 9.4, and analysis in R version 4.2. Model estimation used glmmTMB42, and model fit was assessed using DHARMa43.
Box 1: Outcome measures.
Primary outcome measures
Clinical prescribing error rates
Potential adverse drug event rates (potential Adverse Drug Event [ADE], potential harm severity score ≥3)
Secondary outcome measures
Clinical prescribing error rates by type, and those associated with high-riska medications
Error detection rates - Prescribing errors where there was documentation in patient records indicating that errors had been detected by staff
Actual ADEs (Prescribing errors that resulted in harm, injury or required responsive action (only for the SWCRCT)
Procedural prescribing error rates (only for the SWCRCT)
aHigh-risk medications were defined by the hospital as anti-infectives, potassium and other electrolytes, insulin, narcotics/opioids and sedatives, chemotherapy agents and heparin and other anticoagulants. (Sydney Children’s Hospital Network. High risk medicine register, 2015.)
Reporting summary
Further information on research design is available in the Nature Research Reporting Summary linked to this article.
Supplementary information
Acknowledgements
This research was funded by a National Health and Medical Research Council (NHMRC) partnership project grant with the Sydney Children’s Hospital Network (1094878). Johanna Westbrook holds an NHMRC Leadership Investigator Grant (1174021) and Magdalena Raban holds an NHMRC Early Career Fellowship (1143941). We thank N Board, P Kennedy, J Karnon, C Cowell, CU Lehmann, S Whalen, R Worthington and hospital staff who provided valuable expert input at various stages of the project.
Author contributions
J.W., R.D., T.O., L.D., L.L., M.B., G.A., M.R., V.M., C.M. and D.D. designed the study and were chief investigators on the NHMRC grant awarded to undertake the research. M.R., V.M., A.W., M.G., P.B., A.G., E.F., A.M. and K.S. provided specialist expertise in medication errors and participated variously in the design of the error categories, review of medication charts, and application of the harm scales. J.W., L.L. and T.B. designed the analysis strategy. L.L. and T.B. undertook the analyses. V.M., A.W., C.M., M.G., L.D., G.A., L.W., P.G., R.D., J.W. and M.R. developed the actual harm assessment process and participated in the harm panels. M.D., C.M., P.B., A.G. and L.D. provided specific input in relation to the eMM system implementation, use and design features. All authors contributed to multiple project steering committee meeting discussions to interpret the findings and provide clinical and IT system expertise. J.W. prepared the manuscript which was then reviewed, revised and approved by all authors.
Data availability
This study used individual patient health data that cannot be shared without ethical approval. This also precludes the sharing of aggregated datasets. Analysis datasets are stored according to the ethical approval and access can only be provided to researchers who have received approval from the ethics committee.
Code availability
The code used for preparing and analysing the data is available from the corresponding author on reasonable request.
Competing interests
Johanna Westbrook, Ric Day, Tracey O’Brien, Luciano Dall-Pozza, Ling Li, Melissa Baysari, and Geoffrey Ambler are chief investigators, and Cheryl McCullagh, Madlen Gazarian, Les White, Draga Barbaric are associate investigators on the National Health and Medical Research Council (NHMRC) Partnership grant with the Sydney Children’s Hospital Network (1094878) which funded the project. Les White, at the time of the study was on the Sydney Children’s Hospital Network Board and received a regular stipend. Madlen Gazarian is a steering group member (unpaid role) representing the Royal Australasian College of Physicians with the Australian Digital Health Agency (ADHA) Medicines Safety Program (2017–2020). All other authors have no competing interest to declare.
Footnotes
Publisher’s note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Supplementary information
The online version contains supplementary material available at 10.1038/s41746-022-00739-x.
References
- 1.Gates PJ, et al. Prevalence of medication errors among paediatric inpatients: systematic review and meta-analysis. Drug Saf. 2019;42:13–25. doi: 10.1007/s40264-018-0715-6. [DOI] [PubMed] [Google Scholar]
- 2.Maaskant, J. M. et al. Interventions for reducing medication errors in children in hospital. Cochr. Database System Rev. 10.1002/14651858.CD006208.pub3 (2015). [DOI] [PMC free article] [PubMed]
- 3.Manias E, Kinney S, Cranswick N, Williams A, Borrott N. Interventions to reduce medication errors in pediatric intensive care. Ann. Pharmacother. 2014;48:1313–1331. doi: 10.1177/1060028014543795. [DOI] [PubMed] [Google Scholar]
- 4.Rinke ML, et al. Interventions to reduce pediatric medication errors: a systematic review. Pediatri. 2014;134:338–360. doi: 10.1542/peds.2013-3531. [DOI] [PubMed] [Google Scholar]
- 5.Gates PJ, Hardie R-A, Raban MZ, Li L, Westbrook JI. How effective are electronic medication systems in reducing medication error rates and associated harm among hospital inpatients? A systematic review and meta-analysis. J. Am. Med. Inf. Assoc. 2020;28:167–176. doi: 10.1093/jamia/ocaa230. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 6.Ranji SR, Rennke S, Wachter RM. Computerised provider order entry combined with clinical decision support systems to improve medication safety: a narrative review. BMJ Qual. Saf. 2014;23:773–780. doi: 10.1136/bmjqs-2013-002165. [DOI] [PubMed] [Google Scholar]
- 7.Weir CR, Staggers N, Laukert T. Reviewing the impact of computerized provider order entry on clinical outcomes: the quality of systematic reviews. Int. J. Med. Inf. 2012;81:219–231. doi: 10.1016/j.ijmedinf.2012.01.009. [DOI] [PubMed] [Google Scholar]
- 8.Conn RL, Kearney O, Tully MP, Shields MD, Dornan T. What causes prescribing errors in children? Scoping review. BMJ Open. 2019;9:e028680. doi: 10.1136/bmjopen-2018-028680. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 9.Gates PJ, Meyerson SA, Baysari MT, Westbrook JI. The prevalence of dose errors among paediatric patients in hospital wards with and without health information technology: a systematic review and meta-analysis. Drug Saf. 2019;42:13–25. doi: 10.1007/s40264-018-0715-6. [DOI] [PubMed] [Google Scholar]
- 10.Ivanovska V, Rademaker CMA, van Dijk L, Mantel-Teeuwisse AK. Pediatric drug formulations: a review of challenges and progress. Pediatri. 2014;134:361–372. doi: 10.1542/peds.2013-3225. [DOI] [PubMed] [Google Scholar]
- 11.Caldwell NA, Power B. The pros and cons of electronic prescribing for children. Arch. Dis. Child. 2012;97:124–128. doi: 10.1136/adc.2010.204446. [DOI] [PubMed] [Google Scholar]
- 12.Dufendach KR, et al. Core Functionality in Pediatric Electronic Health Records. Agency for Healthcare Research and Quality; 2015. [PubMed] [Google Scholar]
- 13.Johnson K, Lehmann C. Electronic prescribing in pediatrics: toward safer and more effective medication management. Pediatri. 2013;131:1350–1356. doi: 10.1542/peds.2013-0193. [DOI] [PubMed] [Google Scholar]
- 14.Healthcare Safety Investigation Branch. Weight-based Medication Errors in Children 107 (UK, 2022).
- 15.Prgomet M, Li L, Niazkhani Z, Georgiou A, Westbrook JI. Impact of commercial computerized provider order entry (CPOE) and clinical decision support systems (CDSSs) on medication errors, length of stay, and mortality in intensive care units: a systematic review and meta-analysis. J. Am. Med. Inf. Assoc. 2017;24:413–422. doi: 10.1093/jamia/ocw145. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 16.Walsh KE, et al. Effect of computer order entry on prevention of serious medication errors in hospitalized children. Pediatri. 2008;121:e421–e427. doi: 10.1542/peds.2007-0220. [DOI] [PubMed] [Google Scholar]
- 17.Tolley CL, et al. Factors contributing to medication errors made when using computerized order entry in pediatrics: a systematic review. J. Am. Med. Inf. Assoc. 2017;25:575–584. doi: 10.1093/jamia/ocx124. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 18.Nuckols T, et al. The effectiveness of computerized order entry at reducing preventable adverse drug events and medication errors in hospital settings: a systematic review and meta-analysis. Syst. Rev. 2014;3:56. doi: 10.1186/2046-4053-3-56. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 19.Devin J, Cleary BJ, Cullinan S. The impact of health information technology on prescribing errors in hospitals: a systematic review and behaviour change technique analysis. Syst. Rev. 2020;9:275. doi: 10.1186/s13643-020-01510-7. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 20.Owens K. EMR implementation: big bang or a phased approach? J. Med. Pr. Mngt. 2008;23:279–281. [PubMed] [Google Scholar]
- 21.Holdsworth MT, et al. Impact of computerized prescriber order entry on the incidence of adverse drug events in pediatric inpatients. Pediatri. 2007;120:1058–1066. doi: 10.1542/peds.2006-3160. [DOI] [PubMed] [Google Scholar]
- 22.Holdsworth MT, et al. Incidence and impact of adverse drug events in pediatric inpatients. Arch. Pediatr. Adolesc. Med. 2003;157:60–65. doi: 10.1001/archpedi.157.1.60. [DOI] [PubMed] [Google Scholar]
- 23.Barber, N., Franklin, B. D., Cornford, T., Klecun, E. & Savage, I. Safer, Faster, Better? Evaluating Electronic Prescribing: Report to the Patient Safety Research Programme (Policy Research Program, Department of Health, 2006).
- 24.Baysari MT, et al. Longitudinal study of user experiences of a CPOE system in a pediatric hospital. Int. J. Med. Inf. 2018;109:5–14. doi: 10.1016/j.ijmedinf.2017.10.018. [DOI] [PubMed] [Google Scholar]
- 25.Westbrook JI, et al. The safety of electronic prescribing: manifestations, mechanisms, and rates of system-related errors associated with two commercial systems in hospitals. J. Am. Med Inf. Assoc. 2013;20:1159–1167. doi: 10.1136/amiajnl-2013-001745. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 26.Niazkhani Z, Pirnejad H, Berg M, Aarts J. The impact of computerized provider order entry systems on inpatient clinical workflow: a literature review. J. Am. Med. Inf. Assoc. 2009;16:539–549. doi: 10.1197/jamia.M2419. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 27.Howlett M, Butler E, Lavelle K, Cleary B, Breatnach C. The impact of technology on prescribing errors in pediatric intensive care: a before and after study. Appl. Clin. Inf. 2020;11:323–335. doi: 10.1055/s-0040-1709508. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 28.Doherty C, Mc Donnell C. Tenfold medication errors: 5 years’ experience at a university-affiliated pediatric hospital. Pediatri. 2012;129:916–924. doi: 10.1542/peds.2011-2526. [DOI] [PubMed] [Google Scholar]
- 29.Hou J-Y, et al. The effect of a computerized pediatric dosing decision support system on pediatric dosing errors. J. Food Drug Anal. 2013;21:286–291. doi: 10.1016/j.jfda.2013.07.006. [DOI] [Google Scholar]
- 30.Gazarian M, Graudins LV. Long-term reduction in adverse drug events: an evidence-based improvement model. Pediatri. 2012;129:e1334–e1342. doi: 10.1542/peds.2011-1902. [DOI] [PubMed] [Google Scholar]
- 31.Australian Institute of Health Innovation. Health Innovation Series - e-Medication Safety. https://bit.ly/3y4B9SA (Sydney, 2022).
- 32.Westbrook, J. I. et al. Stepped-wedge cluster randomised controlled trial to assess the effectiveness of an electronic medication management system to reduce medication errors, adverse drug events and average length of stay at two paediatric hospitals: a study protocol. BMJ Open6, 10.1136/bmjopen-2016-011811 (2016). [DOI] [PMC free article] [PubMed]
- 33.Haugen, A. S. et al. Effect of the World Health Organization checklist on patient outcomes: a stepped wedge cluster randomized controlled trial. Ann. Surg.261 (2015). [DOI] [PubMed]
- 34.Sydney Children’s Hospital Network. Accessing eMM Training. https://learning.schn.health.nsw.gov.au/search_results?search_api_fulltext=emm (2019).
- 35.Westbrook J, et al. Effects of two commercial electronic prescribing systems on prescribing error rates in hospital inpatients: a before and after study. PLoS Med. 2012;9:e1001164. doi: 10.1371/journal.pmed.1001164. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 36.National Coordinating Council for Medication Error Reporting and Prevention. NCC MERP Index for Categorizing Medication Errors. www.nccmerp.org (2001). [DOI] [PubMed]
- 37.Gates PJ, Baysari MT, Mumford V, Raban MZ, Westbrook JI. Standardising the classification of harm associated with medication errors: the harm associated with medication error classification (HAMEC) Drug Saf. 2019;42:931–939. doi: 10.1007/s40264-019-00823-4. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 38.Uppsala Monitoring Centre. The Use of the WHO-UMC System for Standardised Case Causality Assessment (Uppsala Monitoring Centre, 2018).
- 39.Hussey MA, Hughes JP. Design and analysis of stepped wedge cluster randomized trials. Contemp. Clin. Trial. 2007;28:182–191. doi: 10.1016/j.cct.2006.05.007. [DOI] [PubMed] [Google Scholar]
- 40.Hemming K, Taljaard M, Forbes A. Analysis of cluster randomised stepped wedge trials with repeated cross-sectional samples. Trials. 2017;18:101. doi: 10.1186/s13063-017-1833-7. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 41.Harrell, F. Regression Modelling Strategies (Springer, 2015).
- 42.Brooks ME, et al. glmmTMB balances speed and flexibility among packages for zero-inflated generalized linear mixed modeling. R. J. 2017;9:378–400. doi: 10.32614/RJ-2017-066. [DOI] [Google Scholar]
- 43.Residual diagnostics for hierarchical (Multi-level/mixed) regression models v. 0.4.3 (2021).
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Supplementary Materials
Data Availability Statement
This study used individual patient health data that cannot be shared without ethical approval. This also precludes the sharing of aggregated datasets. Analysis datasets are stored according to the ethical approval and access can only be provided to researchers who have received approval from the ethics committee.
The code used for preparing and analysing the data is available from the corresponding author on reasonable request.