. 2022 Jul;43(7):665–677. doi: 10.15537/smj.2022.43.7.20220022

Eye lens opacities and cataracts among physicians and healthcare workers occupationally exposed to radiation

A systematic review and meta-analysis

Ayman S Alhasan 1,, Waseem A Aalam 1
PMCID: PMC9749701  PMID: 35830987

Abstract

Objectives:

To evaluate the risk of developing eye lens opacities and cataracts among physicians and healthcare workers occupationally exposed to radiation.

Methods:

Our literature search captured articles published in Embase, Web of Science, PubMed, Cochrane Library, Cumulative Index to Nursing and Allied Health Literature, and Google Scholar databases until September 2021. Then, we retrieved articles reporting cataracts and eye lens opacities induced by radiation exposure among healthcare professionals. The outcomes of interest were cataracts, nuclear opacity, cortical opacity, posterior subcapsular opacity, and any lens opacity.

Results:

Of the 4123 articles identified, 15 studies met the inclusion criteria. Healthcare workers exposed to radiation had a significantly greater risk of posterior subcapsular cataracts (PSCs), cataracts, and any lens opacities than those of the non-exposed participants (p<0.05). The cortical opacity was not significantly different between the exposed and non-exposed participants (p>0.05). Radiation was not determined to be a risk factor for nuclear opacity as it was significantly greater in the control group than the exposed participants. Subgroup analysis revealed that nurses had the highest risk for PSCs (risk ratio = 4.00), followed by interventional cardiologists (risk ratio = 3.85).

Conclusion:

The risk of posterior subcapsular opacities and cataracts is significantly higher in healthcare workers with occupational radiation exposure than in non-exposed workers, highlighting the necessity to enhance and promote the wearing of protective measures with high safety levels.

Keywords: cataract, lens opacities, radiation, meta-analysis, healthcare workers


The lens of the eye is a transparent structure that is sensitive to radiation. The potential health impact of radiation on the eye lens include opacities and visual impairments in the form of cataracts. 1 Cataracts refer to the opacification of the normal crystalline lens of one or both eyes, which alters their transparency and affects the refractive index. This leads to varying degrees of visual impairments, and consequently, decreased life’s quality. 2 Globally, cataracts are considered the second most common cause of visual impairments, observed in 33% of cases with visual impairments. 3 Three morphological types of cataracts have been described in the literature: cortical, nuclear, and subcapsular. 4 The most common cataracts are nuclear cataracts that are identified by a yellowish discoloration of the middle section of the lens and sclerosis. Cortical cataracts are distinguished by white and spoke-like opacities. They affect the cortex and can spread to the periphery of the lens. Subcapsular cataracts are divided into anterior subcapsular cataracts (ASCs) and posterior subcapsular cataracts (PSCs), which affect the anterior and posterior cortex. 5 Posterior subcapsular cataracts account for approximately 10% of all types of cataracts, and almost half of these cases occur concurrently with nuclear, cortical, or ASCs, referred to as mixed cataracts. 6

In general, the causes of lens opacities and cataracts are multifactorial. The factors contributing to the development of cortical and nuclear cataracts have been established. In addition to age, various risk factors contribute to lens opacities and cataract formation. 7 These causes can be genetic or congenital, or associated with disease complications (such as diabetes and glaucoma), trauma, exposure to toxic elements, or radiation. 8,9 In this context, many studies proved that non-ionizing radiation such as Ultraviolet radiation, infrared, radiofrequency, and electric shocks may be possible causes of cataract. 10-13

Epidemiological research and animal studies on pathological mechanisms suggested that cataract development was associated with ionizing radiation. 14,15 Chronic occupational radiation exposure is linked to a higher incidence of cataracts. 16 The impact of continuous ionizing radiation doses on lens alterations has been extensively studied in the medical field. 17-19 Furthermore, many researches have described a greater prevalence of lens opacities and cataracts among healthcare professionals frequently exposed to low doses of radiation. 20 Physicians practicing radiologic-guided interventions, such as interventional cardiologists (ICs) and interventional radiologists, are frequently subjected to ionizing radiation and are considered to have a greater risk of negative effects. Similarly, nurses and technicians working with these healthcare professionals during relevant procedures are highly exposed, especially if they adopt inappropriate protection measures. Radiation-based cataracts are directly associated with radiation dose; conversely, the latent time needed for radiation-based cataract development is conversely associated with radiation dose. 18

Nevertheless, the lowest dose responsible for cataract formation and radiation dose-response relationships has yet to be established. Radiation-induced cataracts have been proposed to take place only following an exposure to high-dose of radiation. However, this hypothesis has been challenged by studies demonstrating that a higher risk of cataracts persists despite a low-dose radiation exposure. 21-23 Posterior subcapsular cataracts are the most common reported lens alteration in health professionals. 19 To decrease the prevelance of cataract among healthcare workers, the International Commission for Radiological Protection has reduced the threshold dose for radiation-induced cataract from 150 millisievert (mSv) to 20 mSv per year, averaged over 5 years with no single year exceeding 50 mSv. 24 Consequently, the new European Directive 2013/59/Euratom (EU2013/59) updated the calssification of workers exposed to radiation and stated that workers receiving an equivalent dose to the lens more than 15 mSv/year should be classified as category A. 25 To prevent health careworkers from exceeding the new lens dose limit, Cornacchia et al 26 suggested to estimate the maximum number of procedures carried out by each healthcare worker and to take into account the nature and time spent.

A systematic review and meta-analysis was carried out by Elmaraezy et al 27 and included articles issued before 2015, which evaluated the risk of developing cataracts induced by radiation among ICs and catheterization lab staff only. The latter group presented a higher risk of radiation-associated posterior lens opacity. Based on these findings, we carried out the present systematic review and meta-analysis to investigate the risk of radiation-associated eye lens opacities and cataracts among all physicians and healthcare workers occupationally exposed to radiation.

Methods

This study was carried out following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines, and written according to the Meta-analysis of Observational Studies in Epidemiology proposal. 28,29 The following PECOS question was formulated; Population (physicians and healthcare workers); Exposure (occupational exposure to ionizing radiation); Comparison (non-exposed physicians and healthcare workers); Outcome (eye lens opacities and cataracts development); Studies (cross-sectional, cohort, and case-control studies).

Both electronic and manual searches were carried out on PubMed, Web of Science, Excerpta Medica dataBASE (EMBASE), Cumulative Index to Nursing and Allied Health Literature, and the Cochrane Library databases from inception until September 2021 to identify potentially eligible articles. We developed the search strategies in collaboration with an expert academic librarian in systematic reviews who is not an author of this paper. Search strategy consisted on applying the EMBASE and Medical Subject Headings search terms when accessible. We used the following terms: “radiation or ionizing radiation” and “cataract or eye lens opacities or risk or effect” and “physicians or health care workers or cardiologists/cardiology or technologists or radiologists or gastroenterologists or orthopedic surgeons.”

Eligibility criteria

We screened relevant articles by their title and abstract after removing duplicates. Studies were eligible for inclusion if they addressed lens opacities and cataracts in healthcare workers or physicians exposed to ionising radiation. The remaining studies were examined to evaluate eligibility.

The inclusion criteria for articles were as follows: 1) cross-sectional, cohort, and case-control studies reporting the prevalence of lens opacities and cataracts induced by radiation among physicians or healthcare workers; 2) the use of questionnaires to collect demographic information and work-related information; 3) publications reporting sufficient information to calculate risk ratios; and 4) studies published as original articles. The exclusion criteria for articles included: 1) full text not electronically accessible; 2) publication in non-English language; 3) comments, letters, editorials, protocols, guidelines, and review papers; 4) radiation exposure effects in animal studies; and 5) studies with insufficient outcome data.

We assessed the eligibility of all potential articles according to above criteria. A third author solved the disagreements, if exist, from literature screening.

After verifying the inclusion and exclusion criteria, we retrieved data from the eligible studies. We collected the following information using a standardized data sheet: 1) article ID (name of the first author, publication year); 2) article design; 3) number and age of participants (exposed and non-exposed); 4) country of study; 5) duration of occupational work; 6) lens opacity scoring system used; 7) dose of radiation; and 8) outcomes. A third reviewer was consulted to check the data sheet for accuracy. If some relevant data were not available, we contacted the corresponding author by email to request the missing data; if no response was received after a reminder, the study was excluded from the systematic-review and meta-analysis.

Quality assessment

We evaluated the quality of the cohort and cross-sectional articles, selection bias, comparability of the exposed and control participants, and outcome evaluation following the Newcastle-Ottawa Scale (NOS). The NOS cross-sectional and cohort systems evaluated 3 sections: 1) selection of exposed and non-exposed groups (maximum of 4 and 5 points for cohort and cross-sectional studies); 2) comparability of study groups (1 or 2 points); and 3) evaluation of outcomes (1, 2, or 3 points). Quality evaluation was carried out independently. The discordance was resolved by discussion. Articles with 0 or 1 ★ in the selection section or 0 2605 in the comparability section or 0 or 1 ★ in the outcome section were assigned a poor-quality score. Articles with 2 ★ in the selection section and one or 2 ★ in the comparability section and 2 or 3 ★ in the outcome section were assigned a fair-quality score. Articles with 3 or 4 ★ in the selection section and 1 or 2 ★ in the comparability section and 2 or 3 ★ in the outcome section were assigned a good-quality score. 30

The outcomes of interest were cataracts, nuclear opacity, cortical opacity, posterior subcapsular opacity, and any lens opacity.

Statistical analysis

RevMan, version 5.4 (Cochrane Collaboration, Oxford, United Kingdom) was used to carry out statistical analyses. Risk ratios (RRs) and 95% confidence intervals (CIs) were calculated to assess the outcomes. A p-value of <0.05 was considered significant. We carried out the Cochrane Chi-squared test to estimate the heterogeneity of the articles, with a a p-value of <0.05 indicating the existence of heterogeneity. To estimate the impact of heterogeneity on the meta-analysis, I 2 values were calculated. Heterogeneity values of ≥50% and p<0.05 indicated a moderate to high degree of heterogeneity in pooled articles. We used a fixed-effects design when I 2 <50% with p>0.05; otherwise, we adopted a random-effects design. 31 Furthermore, we carried out a sensitivity and subgroup analyses to assess the possible source of heterogeneity. We carried out Egger’s test using Statistical Package for Social Sciences, version 25 (IBM Corp., Armonk, NY, USA) to evaluate publication bias, which was further estimated by visual inspection of symmetry in the funnel plots.

Results

We identified 4123 articles for screening, of which 2238 abstracts were identified as potentially eligible and retrieved for full text review. In total, 15 articles met the eligibility criteria and were included in this study. Figure 1 presents the PRISMA flowchart.

Figure 1.

Figure 1

- Preferred Reporting Items for Systematic Reviews and Meta-Analyses flowchart of this meta-analysis

All included articles were published between 2009-2019 and were distributed among 10 countries. Among the 15 articles included in this study, 11 were cohort studies, and 4 were cross-sectional studies. The sample sizes of the included articles varied from 37-3240 participants, and their ages ranged between 19-75 years. The duration of occupational work ranged from 3 months to 50 years. Three types of lens scoring systems were used: Lens Opacities Classification System II (LOCS II), System III (LOCS III), and Modified Merriam-Focht (MF) scoring system. Quantitative measures of radiation ranged from 0.5 μSv to 43 Sv. Table 1 describes the data extarcted from the articles used in the present meta-analysis.

Table 1.

- List of articles used in this meta-analysis with their geographic distribution, study design, participant characteristics, and outcomes.

Study Study design Country Participants (occupational category) Age (years) Duration of occupational work Lens scoring system Outcomes (lens area assessed) Radiation dose
n Exposed Non-exposed
Andreassi et al 44 Cohort Italy 746 466 (218 ICs and electrophysiologists, 191 nurses, and 57 technicians) 280 35-53 5-24 years ND Cataract Median lifetime effective dose physicians: 21 mSv nurses: 7 mSv
Auvinen et al 33 Cohort Finland 37 21 (14 radiologists, 2 interventional radiologists, 3 cardiologists, and 2 surgeons) 16 (physicians excluding radiologists and cardiologists) 45-74 At least 15 years LOCS II Posterior subcapsular, cortical change, nuclear opalescence, nuclear color, nuclear opacities Mean cumulative radiation dose based on dosimeter readings: 111 mSv
Barbosa et al 34 Cross-sectional Brazil 200 112 ICs and healthcare workers in cardiac hemodynamics: nurse, physician, technician, or technologist 88 (cardiologists not exposed to radiation) 36-66 62% of the professionals: <20 years of work, and 31% presented between 5-10 years of work. LOCS III Posterior subcapsular, lens opacities, cortical cataract ND
Ciraj-Bjelac et al 18 Cohort Austria 89 56 ICs and 11 nurses working in interventional cardiology 22 age- and gender-matched unexposed healthcare staff 25-64 1-33 MF scoring system Posterior lens changes 0.01-43 Gy
Ciraj-Bjelac et al 17 Cohort Austria 86 52 healthcare workers in interventional cardiology 34 age- and gender-matched unexposed healthcare staff 19-67 1-20 MF scoring system Posterior lens changes Cumulative dose: 0.026-21 Sv
Domienik-Andrzejewska et al 45 Cohort Poland 147 69 (interventional cardiologists) 78 physicians, scientific/administrative staff, and nurses 37-68 5-36 years LOCS III Nuclear opalescence, nuclear color, cortical opacities, posterior subcapsular opacities ICs: 224 mSv (left eye)85 mSv (right eye)
Jacob et al 36 Cross-sectional France 205 106 ICs 99 non-medical workers >40 ND LOCS III Any lens opacities, nuclear opacities, cortical opacities, posterior subcapsular opacities ND
Karatasakis et al 46 Cross-sectional USA 117 99 ICs and cath-lab staff 18 participants (industry, research staff, and others) 36-60 ND MF scale Any lens opacities, cortical and posterior subcapsular lens changes, Frank opacities Cumulative radiation dose to the lens: 0.1-22.5 Gy (Mean: 4.5)
Matsubara et al 40 Cohort Thailand 85 Cardiac catheterization laboratories staff: 7 ICs, 41 nurses, and technologists 37 age- and gender-matched volunteers 19-59 0.4-35 years MF scale Posterior lens opacities Cumulative radiation dose to the lens: 0.03-8.5 Sv
Milacic et al 47 Cohort Serbia 3240 1560 health workers 1680 health workers 28-52 6-26 years ND Cataract Equivalent doses 0.5-8 μSv/h
Rajabi et al 48 Cohort Iran 95 81 interventional cardiology members (44 ICs and 37 technicians) 14 nurses not working in interventional sites 26-54 At least 4 years LOCS III Cataract At least 1 mSv for at least 4 years
Scheidemann-Wesp et al 49 Cohort Germany 61 17 ICs 18 physicians 37-75 8-50 years LOCS III Nuclear opacity, cortical opacity ND
Vano et al 19 Cohort Colombia and Uruguay 209 58 interventional cardiologists and 58 nurses and technicians 93 unexposed non-healthcare workers of similar age 20-69 1-40 MF scale Posterior subcapsular lens opacities Cumulative lens dose range: 0.1-27 Sv
Vano et al 50 Cohort Argentina, Colombia, and Uruguay 145 54 ICs and 69 nurses and technicians 91 non-medical professionals 20-66 4-25 MF scale Posterior subcapsular lens changes Cumulative eye dose range: 0.1-18.9 Sv
Yuan et al 51 Cross-sectional Taiwan 1866 733 cardiologists performing cardiac catheterization 988 cardiologists not performing cardiac catheterization 35-50 ND ND Cataract ND

ICs: interventional cardiologists, ND: not defined, mSv: millisievert, LOCS II: Lens Opacities Classification System, version II, LOCS III: The Lens Opacities Classification System III, Gy: the gray, Sv: stroke volume, cath-lab: catheterization laboratory, MF: Modified Merriam-Focht, μSv/h: micro-Sieverts/hour

Quality assessment

Almost half of the articles were assessed to be of good quality (n=7), while 8 were of fair quality. Tables 2 and 3 summarize the quality assessment scores for cohort and cross-sectional studies.

Table 2.

- The quality evaluation of the cohort studies using the Modified Newcastle-Ottawa scale.

Articles Selection Comparability Outcome Quality score
Representativeness of the sample Selection of non-exposed group Ascertainment of exposure Outcome absent at the start of study Cohort statistical analysis Evaluation of outcome Sufficient follow-up duration for outcomes to occur Adequacy of follow-up
Andreassi et al 44 0 0 0 Fair
Auvinen et al 33 Good
Ciraj-Bjelac et al 18 0 Fair
Ciraj-Bjelac et al 17 0 Fair
Domienik-Andrzejewska et al 45 0 Good
Matsubara et al 40 0 Fair
Milacic et al 47 0 Good
Rajabi et al 48 0 Fair
Scheidemann-Wesp et al 49 0 0 Fair
Vano et al 19 0 Fair
Vano et al 50 0 Fair

★Quality score assigned for each category as per the Newcastle-Ottawa Scale criteria

Table 3.

- The quality evaluation of the cross-sectional studies using the Modified Newcastle-Ottawa scale.

Studies Selection Comparability Outcome Quality score
Representativeness of sample Sample size Comparability of non-respondents Ascertainment of exposure Statistical analysis design characteristics Evaluation of outcome Statistical analysis
Barbosa et al 34 0 ★★ Good
Jacob et al 36 0 ★★ Good
Karatasakis et al 46 ★★ Good
Yuan et al 51 0 ★★ Good

★Quality score assigned for each category as per the Newcastle-Ottawa Scale criteria

Of the cohort studies (n=11), 4 scored highly in the selection domain. Sample representativeness was high, and samples were scored with a star for being somewhat representative of the target population. Exposed and non-exposed participants were drawn from the same community in 4 articles. All of the cross-sectional studies (n=4) had somewhat representative or truly representative samples. Non-response characteristics were well described for all studies. Validated measurement tools were available or described well in only one study.

Of the cohort studies, only 3 described the presence of the outcome at the beginning of the cohort study; the remaining articles scored one star. All of the studies described statistical analyses comparing exposed and non-exposed groups and used adjusted analyses. All cross-sectional studies controlled for the outcomes and additional factors (namely, age) scored 2 stars.

Of the cohort studies, only 2 did not describe the tools used for outcome assessment. All studies scored one star for follow-up with majority of the cohort after an adequate time period. All cross-sectional studies adopted validated assessment tools and used adequate and appropriate statistical analyses.

Outcome measures

Four of the included studies reported the effects of occupational radiation exposure on cataract formation. As the heterogeneity was low (χ 2 =6.88, p=0.08, I 2 =56%), we adopted a fixed effects design. The forest plot analysis showed that cataract between the non-exposed and exposed participants was significantly different. Compared to the control group, the exposed group had approximately 5 times the risk of developing cataracts (RR=4.96; 95% CI: [4.23-5.82]; p<0.00001; Figure 2).

Figure 2.

Figure 2

- Forest plot illustrating the results of cataract outcomes in non-exposed and exposed groups.

Five of the included studies reported the effects of occupational radiation exposure on nuclear opacity. As the heterogeneity was low (χ 2 = 4.40, p=0.36, I 2 =9%), we adopted a fixed effects design. The forest plot analysis demonstrated that the nuclear opacity between the non-exposed and exposed groups was significantly different (RR=0.83; 95% CI: [0.70-0.99]; p=0.04), indicating that radiation was not a risk factor for nuclear opacity (Figure 3).

Figure 3.

Figure 3

- Forest plot illustrating the results of nuclear opacity in non-exposed and exposed groups.

Six of the included studies reported the effects of occupational radiation exposure on cortical opacity. As the heterogeneity was low (χ 2 =3.98, p=0.55, I 2 =0%), we adopted a fixed effects design. The forest plot analysis showed that the cortical opacity between the non-exposed and exposed participants was not significantly different (RR=0.87; 95% CI: [0.64-1.17]; p=0.35; Figure 4).

Figure 4.

Figure 4

- Forest plot illustrating the results of cortical opacity in non-exposed and exposed groups.

Ten of the included studies reported the effects of occupational radiation exposure on posterior subcapsular opacity. As the heterogeneity was low (χ 2 =8.88, p=0.45, I 2 =0%), we used a fixed effects design. The forest plot analysis revealed that the posterior subcapsular opacity between the non-exposed and exposed groups was significantly different. Interestingly, the exposed group had approximately 3 times the risk of developing posterior subcapsular opacity compared to the non-exposed participants (RR=3.26; 95% CI: [2.39-4.43]; p<0.00001; Figure 5).

Figure 5.

Figure 5

- Forest plot illustrating the results of posterior subcapsular opacity in non-exposed and exposed groups.

Two of the included articles mentioned the effects of occupational radiation exposure on lens opacity (cortical and posterior subcapsular). As the heterogeneity was low (χ2=0.02, p=0.89, I 2 =0%), we adopted a fixed effects design. The forest plot analysis revealed that any lens opacity between the non-exposed and exposed groups was significantly different. Compared to the non-exposed participants, the exposed group had approximately twice the risk of developing any lens opacity (RR=2.25; 95% CI: [1.19-4.24]; p=0.01; Figure 6).

Figure 6.

Figure 6

- Forest plot illustrating the results of any lens opacity in non-exposed and exposed groups.

A sensitivity analysis was carried out to assess the origin of heterogeneity in the pooled RRs of cataract formation, nuclear opacity, cortical opacity, posterior subcapsular opacity, and any lens opacity. The outcomes did not differ substantially, indicating that the meta-analysis had strong reliability. In the leave-one-out sensitivity analysis, the RRs of cataract formation ranged from 4.15 (95% CI: [2.01-8.56]) to 5.12 (95% CI: [4.36-6.02]), nuclear opacity ranged from 0.78 (95% CI: [0.57-1.05]) to 0.86 (95% CI: [0.72-1.03]), cortical opacity ranged from 0.78 (95% CI: [0.56-1.08]) to 0.94 (95% CI: [0.63-1.39]), posterior subcapsular opacity ranged from 2.93 (95% CI: [2.06-4.16]) to 3.48 (95% CI: [2.52-4.79]), and any lens opacity ranged from 2.20 (95% CI: [1.13-4.28]) to 2.55 (95% CI: [0.36-18.17])(Table 4).

Table 4.

- Leave-one-out sensitivity analysis of risk ratios of analyzed outcomes.

Outcomes/study excluded Odds ratio (95% CI) P-values
Cataract formation
Andreassi et al 44 4.94 (4.21-5.79) <0.00001
Milacic et al 47 4.15 (2.01-8.56) 0.0001
Rajabi et al 48 4.90 (4.18-5.74) <0.00001
Yuan et al 51 5.12 (4.36-6.02) <0.00001
Nuclear opacity
Auvinen et al 33 0.85 (0.70-1.02) 0.09
Domienik-Andrzejewska et al 45 0.85 (0.70-1.03) 0.10
Jacob et al 36 0.78 (0.57-1.05) 0.11
Karatasakis et al 46 0.80 (0.68-0.96) 0.01
Scheidemann-Wesp et al 49 0.86 (0.72-1.03) 0.10
Cortical opacity
Auvinen et al 33 0.92 (0.67-1.26) 0.61
Barbosa et al 34 0.78 (0.56-1.08) 0.13
Domienik-Andrzejewska et al 45 0.88 (0.61-1.27) 0.49
Jacob et al 36 0.94 (0.63-1.39) 0.74
Karatasakis et al 46 0.85 (0.63-1.15) 0.29
Scheidemann-Wesp et al 49 0.86 (0.64-1.17) 0.34
Posterior subcapsular opacity
Auvinen et al 33 3.28 (2.40-4.47) <0.00001
Barbosa et al 34 3.13 (2.29-4.29) <0.00001
Ciraj-bjelac et al 18 3.11 (2.27-4.26) <0.00001
Ciraj-bjelac et al 17 3.42 (2.44-4.81) <0.00001
Domienik-Andrzejewska et al 45 3.48 (2.52-4.79) <0.00001
Jacob et al 36 3.24 (2.34-4.49) <0.00001
Karatasakis et al 46 3.34 (2.44-4.56) <0.00001
Matsubara et al 40 3.15 (2.31-4.31) <0.00001
Vano et al 19 3.51 (2.46-4.99) <0.00001
Vano et al 50 2.93 (2.06-4.16) <0.00001
Any lens opacity
Barbosa et al 34 2.55 (0.36-18.17) 0.35
Karatasakis et al 46 2.20 (1.13-4.28) 0.02

CI: confidence interval

A subgroup analysis for the outcome of posterior subcapsular opacity was carried out. We excluded the other outcomes due to the limited number of articles. The RRs of posterior subcapsular opacity in the exposed and non-exposed participants differed following the study design, radiation dose, period of publication, and occupational work of the participants. According to the study design, the RRs of posterior subcapsular opacity in the cohort and cross-sectional studies were similar.

When radiation dose was adopted as a moderator, the RR differed significantly between the studies. We detected the highest RR of posterior subcapsular opacity with an estimated cumulative ocular dose of ≥1 Sv (RR=3.38, p<0.0001). However, the exposed and non-exposed groups with lower radiation dose of <1 Sv did not reveal a notable difference (p=0.57). Furthermore, the RR of posterior subcapsular opacity exhibited a higher trend in studies carried out before 2015 than in those carried out after 2015. However, it was not statistically significant.

The RR of the posterior subcapsular opacity differed among healthcare workers. We observed the highest RR among nurses (RR=4.00, 95% CI: [1.41-11.30]), followed by ICs (RR=3.85, 95% CI: [2.79-5.30]), technicians and nurses (RR=2.88, 95% CI: [1.75-4.72]), physicians (RR=2.29, 95% CI: [0.26-19.97]), and technicians (RR=2.08, 95% CI: [0.96-4.50]). Moreover, we did not detect a significant difference among the technicians, physicians, and controls (p>0.05; Table 5).

Table 5.

- Subgroup analyses for the risk ratios of posterior subcapsular opacity.

Subgroups No. of studies Risk ratio (95% CI) P-values Heterogeneity
Chi 2 I 2 P-values
Study design
Cohort 7 3.20 (2.28-4.49) <0.0001 6.69 10% 0.35
Cross-sectional 3 3.53 (1.70-7.31) 0.0007 2.11 5% 0.35
Radiation dose
<1 Sv 2 1.36 (0.48-3.82) 0.57 0.31 0% 0.58
≥1 Sv 6 3.38 (2.37-4.82) <0.0001 5.25 5% 0.39
Study period
Before 2015 6 3.33 (2.37-4.68) <0.0001 3.15 0% 0.68
After 2015 4 2.95 (1.42-6.11) 0.004 5.44 45% 0.14
Occupational work
Physicians (radiologists, interventional radiologists, cardiologists, and surgeons) 1 2.29 (0.26-19.97) 0.45 ND ND ND
Interventional cardiologists 9 3.85 (2.79-5.30) <0.0001 9.60 17% 0.29
Technicians 2 2.08 (0.96-4.50) 0.06 0.14 0% 0.70
Nurses 3 4.00 (1.41-11.30) 0.009 2.73 17% 0.30
Technicians and nurses 2 2.88 (1.75-4.72) <0.0001 2.73 63% 0.10

No.: number, CI: confidence interval, Chi 2 : Chi-square test, Sv: stroke volume, ND: not defined

Publication bias

Based on the Egger’s regression test as well as the visual examination of the funnel plot, we detected no proof of publication bias for any of the 5 outcomes analyzed (p>0.05; Figure 7).

Figure 7.

Figure 7

- Funnel plots demonstrating no proof of publication bias in the included articles in terms of A) cataract formation, B) nuclear opacity, C) cortical opacity, D) posterior subcapsular opacity, and E) any lens opacity.

Discussion

The present study, comprising 15 articles assessed the risk of developing lens opacities and cataracts among physicians and healthcare professionals frequently exposed to ionizing radiation. The present meta-analysis demonstrated that physicians and healthcare professionals exposed to radiation had a notable higher risk of cataracts and PSC opacity than the non-exposed workers. These results are in line with previous reports indicating that PSC opacity is the most common kind of lens opacity linked to ionizing radiation. 32 Auvinen et al 33 reported that the most frequent disorder among physicians was posterior subcapsular opacity (prevalence ratio of 2.1), followed by nuclear opacity (0.82) and cortical opacity (0.41). Similarly, Barbosa et al 34 reported an elevated incidence of any type of lens opacity (38%) followed by PSCs (13%) among healthcare professionals working in the area of cardiac hemodynamics in Brazil. The incidence of PSC opacity is 2-fold higher in occupationally exposed healthcare workers in comparison with the non-exposed workers. 17,19 Clinical and epidemiologic research investigating radiation exposure in healthcare workers has reported the incidence of radiation-based cataracts in the healthcare field. Chodick et al 21 identified 2382 cataracts and 647 cataract extractions among 35705 radiology technologists with an average radiation dose of 28.1 mGy. Additionally, the odds ratio of any lens opacities was 0.13 in Finnish physicians. 22 Consequently, organizations such as the National Council on Radiation Protection and Measurements established guidelines and reports to promote awareness in health professionals and evaluate the risk of developing lens opacities due to chronic radiation exposure. 35

Our meta-analysis demonstrated that radiation exposure did not seem to induce nuclear or cortical opacities, in agreement with previous studies. Coppeta et al 20 demonstrated that nuclear opacity was not associated with occupational radiation exposure. The occupational lens opacities and cataract in interventional cardiology study in France revealed that nuclear and cortical opacities were not radiation-based among ICs, while the prevalence of PSCs was significantly higher. 36 Similar findings were described in a meta-analysis carried out by Elmaraezy et al, 27 which revealed a significantly higher incidence of PSCs among ICs but no notable difference in nuclear and cortical opacities between the exposed and control participants.

With regard to dose-response relationships, the risk of PSCs was notably higher in the ≥1 Sv group in comparison with the <1 Sv group, in agreement with precedents reports showing a notable association between occupational radiation dose and the risk of cataracts. 36 Several epidemiological studies, animal studies, and other reports have suggested a progressive increase in cataract formation with increased doses of ionizing radiation. 24,37,38 However, the meta-analysis of Elmaraezy et al 27 reported contradictory results, which might be due to the limited sample size and study period (pre-2015).

A subgroup analysis was carried out to evaluate the impact of the occupation of healthcare workers on cataract development. We observed that the risk of PSCs was higher in nurses than in other healthcare professionals. Conversely, Rehani et al 39 reported that the incidence of radiation-associated PSCs among ICs was 52% and among nurses was 45%. Similarly, Vano et al 19 demonstrated that nearly one-third of ICs presented with high rates of PSCs after 30 years of work. In contrast, this meta-analysis demonstrated that nurses presented with a higher risk of PSCs than that of ICs. This is expected considering nurses stand next to the patient’s bed for a long time without a protective screen, in contrast to ICs. As such, nurses are highly exposed to radiation. 40 Accordingly, this meta-analysis highlights the need to adopt adequate strategies to decrease radiation doses, ensure adequate protection of all healthcare workers, and promote the implementation of more appropriate radiation protection measures that encompass all staff members in the interventional room.

Study strengths and limitations

In this study, a literature search was carried out using 5 different databases. The major strength of the present study is the considerable scale of included articles and the large number of participants analyzed. Unpublished articles were not included. However, the funnel plot did not reveal a publication bias. Another major strength of our meta-analysis is the high methodological quality of the included articles, which presented with good or fair-quality scores. Furthermore, radiation dose spanning the entire career of the participants was available for the majority of studies, which permitted dose-response analysis. Notably, this meta-analysis did not detect statistical heterogeneity, indicating that all studies demonstrated the same effect. Most studies (12/15) used the validated lens opacity grading systems (LOCS II, LOCS III, and MF scale), which ensured standardized outcome assessments. However, the use of different classification systems constituted an important source of discrepancies in this meta-analysis. The MF system is specifically applicable for posterior lens opacities, while LOCS III evaluates any type of cataracts. 41,42 These grading systems also employ different methods in evaluating opacities, including retro-illumination, Scheimpflug imaging, and dilated slit-lamp biomicroscopy. 43 These differences constitute a significant limitation when comparing the results of different studies and consequently increase the complexity of pooled analysis. Therefore, cataract classification systems should be standardized for an effective assessment of lens opacities. 43

In conclusion, the present meta-analysis revealed a significantly higher risk of posterior subcapsular opacities and cataracts among healthcare workers occupationally exposed to radiation, suggesting that radiation exposure levels are correlated with a greater risk of cataracts. This meta-analysis indicated that nurses and ICs occupationally exposed to radiation are more prone to developing lens opacities, which reinforces the urgent requirement of strict compliance with the wearing of protective tools to minimize lens exposure to radiation. Also, a medical surveillance program should be implemented to systematically assess and detect early signs of adverse health effects among healthcare workers potentially exposed to ionizing radiation in the course of their employment.

Acknowledgment

The authors gratefully acknowledge Dr. Safa Boujemaa from Biologica Training & Consulting group for developing the search strategy and the statistical analysis. We also would like to thank Editage (www.editage.com) for English language editing.

Footnotes

Disclosure. Authors have no conflict of interests, and the work was not supported or funded by any drug company.

References

  • 1. Alkhorayef M, Babikir E, Alrushoud A, Al-Mohammed H, Sulieman A.. Patient radiation biological risk in computed tomography angiography procedure. Saudi J Biol Sci 2017; 24: 235–240. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 2. National Institute for Health and Care Excellence (UK). Cataracts in adults: management. [Updated 2017; 2021. Oct 26]. Available from: https://www.ncbi.nlm.nih.gov/books/NBK464182/ [PubMed]
  • 3. Pascolini D, Mariotti SP.. Global estimates of visual impairment: 2010. Br J Ophthalmol 2012; 96: 614–618. [DOI] [PubMed] [Google Scholar]
  • 4. Richter GM, Torres M, Choudhury F, Azen SP, Varma R.. Risk factors for cortical, nuclear, posterior subcapsular, and mixed lens opacities: the Los Angeles Latino eye study. Ophthalmology 2012; 119: 547–554. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 5. Chew M, Chiang PP, Zheng Y, Lavanya R, Wu R, Saw SM, et al. The impact of cataract, cataract types, and cataract grades on vision-specific functioning using Rasch analysis. Am J Ophthalmol 2012; 154: 29–38. [DOI] [PubMed] [Google Scholar]
  • 6. Richter-Mueksch S, Sacu S, Weingessel B, Vécsei-Marlovits VP, Schmidt-Erfurth U.. The influence of cortical, nuclear, subcortical posterior, and mixed cataract on the results of microperimetry. Eye (Lond) 2011; 25: 1317–1321. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 7. Omer H, Alameen S, Mahmoud WE, Sulieman A, Nasir O, Abolaban F.. Eye lens and thyroid gland radiation exposure for patients undergoing brain computed tomography examination. Saudi J Biol Sci 2021; 28: 342–346. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 8. Mahdi AM, Rabiu M, Gilbert C, Sivasubramaniam S, Murthy GV, Ezelum C, et al. Prevalence and risk factors for lens opacities in Nigeria: results of the national blindness and low vision survey. Invest Ophthalmol Vis Sci 2014; 55: 2642–2651. [DOI] [PubMed] [Google Scholar]
  • 9. Robman L, Taylor H.. External factors in the development of cataract. Eye (Lond) 2005; 19: 1074–1082. [DOI] [PubMed] [Google Scholar]
  • 10. Modenese A, Gobba F.. Cataract frequency and subtypes involved in workers assessed for their solar radiation exposure: a systematic review. Acta Ophthalmol 2018; 96: 779–788. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 11. Aly EM, Mohamed ES.. Effect of infrared radiation on the lens. Indian J Ophthalmol 2011; 59: 97–101. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 12. Elder JA. Ocular effects of radiofrequency energy. Bioelectromagnetics 2003; Suppl 6: S148–S161. [DOI] [PubMed] [Google Scholar]
  • 13. Baranwal VK, Satyabala K, Gaur S, Dutta AK.. A case of electric cataract. Med J Armed Forces India 2014; 70: 284–285. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 14. Dauer LT, Ainsbury EA, Dynlacht J, Hoel D, Klein BEK, Mayer D, et al. Guidance on radiation dose limits for the lens of the eye: overview of the recommendations in NCRP commentary No. 26. Int J Radiat Biol 2017; 93: 1015–1023. [DOI] [PubMed] [Google Scholar]
  • 15. Bouffler S, Ainsbury E, Gilvin P, Harrison J.. Radiation-induced cataracts: the Health Protection Agency’s response to the ICRP statement on tissue reactions and recommendation on the dose limit for the eye lens. J Radiol Prot 2012; 32: 479–488. [DOI] [PubMed] [Google Scholar]
  • 16. Picano E, Vano E.. Radiation exposure as an occupational hazard. EuroIntervention 2012; 8: 649–653. [DOI] [PubMed] [Google Scholar]
  • 17. Ciraj-Bjelac O, Rehani M, Minamoto A, Sim KH, Liew HB, Vano E.. Radiation-induced eye lens changes and risk for cataract in interventional cardiology. Cardiology 2012; 123: 168–171. [DOI] [PubMed] [Google Scholar]
  • 18. Ciraj-Bjelac O, Rehani MM, Sim KH, Liew HB, Vano E, Kleiman NJ.. Risk for radiation-induced cataract for staff in interventional cardiology: is there reason for concern? Catheter Cardiovasc Interv 2010; 76: 826–834. [DOI] [PubMed] [Google Scholar]
  • 19. Vano E, Kleiman NJ, Duran A, Rehani MM, Echeverri D, Cabrera M.. Radiation cataract risk in interventional cardiology personnel. Radiat Res 2010; 174: 490–495. [DOI] [PubMed] [Google Scholar]
  • 20. Coppeta L, Pietroiusti A, Neri A, Spataro A, De Angelis E, Perrone S, et al. Risk of radiation-induced lens opacities among surgeons and interventional medical staff. Radiol Phys Technol 2019; 12: 26–29. [DOI] [PubMed] [Google Scholar]
  • 21. Chodick G, Bekiroglu N, Hauptmann M, Alexander BH, Freedman DM, Doody MM, et al. Risk of cataract after exposure to low doses of ionizing radiation: a 20-year prospective cohort study among US radiologic technologists. Am J Epidemiol 2008; 168: 620–631. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 22. Mrena S, Kivelä T, Kurttio P, Auvinen A.. Lens opacities among physicians occupationally exposed to ionizing radiation--a pilot study in Finland. Scand J Work Environ Health 2011; 37: 237–243. [DOI] [PubMed] [Google Scholar]
  • 23. Shore RE. Radiation and cataract risk: impact of recent epidemiologic studies on ICRP judgments. Mutat Res Rev Mutat Res 2016; 770: 231–237. [DOI] [PubMed] [Google Scholar]
  • 24. International Commission on Radiological Protection. ICRP annual report 2011. [Updated 2011; 2021 Nov 19]. Available from: https://www.icrp.org/docs/ICRP%20Annual%20%20Report%202011.pdf
  • 25. The Council of the European Union. Council Directive 2013/59/Euratom of 5 December 2013 laying down basic safety standards for protection against the dangers arising from exposure to ionizing radiation, and repealing Directives 89/618/Euratom, 90/641/Euratom, 96/29/Euratom, 97/43/Euratom and 2003/122/Euratom. Off J Eur Union 2014: 17. [Google Scholar]
  • 26. Cornacchia S, Errico R, La Tegola L, Maldera A, Simeone G, Fusco V, et al. The new lens dose limit: implication for occupational radiation protection. Radiol Med 2019; 124: 728–735. [DOI] [PubMed] [Google Scholar]
  • 27. Elmaraezy A, Ebraheem Morra M, Tarek Mohammed A, Al-Habaa A, Elgebaly A, Abdelmotaleb Ghazy A, et al. Risk of cataract among interventional cardiologists and catheterization lab staff: a systematic review and meta-analysis. Catheter Cardiovasc Interv 2017; 90: 1–9. [DOI] [PubMed] [Google Scholar]
  • 28. Liberati A, Altman DG, Tetzlaff J, Mulrow C, Gøtzsche PC, Ioannidis JP, et al. The PRISMA statement for reporting systematic reviews and meta-analyses of studies that evaluate health care interventions: explanation and elaboration. PLoS Med 2009; 6: e1000100. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 29. Stroup DF, Berlin JA, Morton SC, Olkin I, Williamson GD, Rennie D, et al. Meta-analysis of observational studies in epidemiology: a proposal for reporting. Meta-analysis Of Observational Studies in Epidemiology (MOOSE) group. JAMA 2000; 283: 2008–2012. [DOI] [PubMed] [Google Scholar]
  • 30. Stang A. Critical evaluation of the Newcastle-Ottawa scale for the assessment of the quality of nonrandomized studies in meta-analyses. Eur J Epidemiol 2010; 25: 603–605. [DOI] [PubMed] [Google Scholar]
  • 31. Borenstein M, Hedges LV, Higgins JP, Rothstein HR.. A basic introduction to fixed-effect and random-effects models for meta-analysis. Res Synth Methods 2010; 1: 97–111. [DOI] [PubMed] [Google Scholar]
  • 32. Hammer GP, Scheidemann-Wesp U, Samkange-Zeeb F, Wicke H, Neriishi K, Blettner M.. Occupational exposure to low doses of ionizing radiation and cataract development: a systematic literature review and perspectives on future studies. Radiat Environ Biophys 2013; 52: 303–319. [DOI] [PubMed] [Google Scholar]
  • 33. Auvinen A, Kivelä T, Heinävaara S, Mrena S.. Eye lens opacities among physicians occupationally exposed to ionizing radiation. Ann Occup Hyg 2015; 59: 945–948. [DOI] [PubMed] [Google Scholar]
  • 34. Barbosa AHP, Medeiros RB, Corpa AMR, Higa FS, Souza MT de, Barbosa PL, et al. Prevalence of lens opacity in interventional cardiologists and professional working in the hemodynamics in Brazil. [Updated 2019; 2021 Oct 17]. Available from: https://www.scielo.br/j/abc/a/CQBQRLzv4JMQqy8FY5X3WQN/?lang=en [DOI] [PMC free article] [PubMed]
  • 35. National Council on Radiation Protection and Measurements. NCRP annual report 2011. [Updated 2011; 2021 Nov 10]. Available from: http://ncrponline.org/wp-content/%20themes/ncrp/PDFs/NCRP_2011_Annual_Rpt.pdf
  • 36. Jacob S, Boveda S, Bar O, Brézin A, Maccia C, Laurier D, et al. Interventional cardiologists and risk of radiation-induced cataract: results of a French multicenter observational study. Int J Cardiol 2013; 167: 1843–1847. [DOI] [PubMed] [Google Scholar]
  • 37. Fish DE, Kim A, Ornelas C, Song S, Pangarkar S.. The risk of radiation exposure to the eyes of the interventional pain physician. Radiol Res Pract 2011; 2011: 609537. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 38. Shore RE, Neriishi K, Nakashima E.. Epidemiological studies of cataract risk at low to moderate radiation doses: (not) seeing is believing. Radiat Res 2010; 174: 889–894. [DOI] [PubMed] [Google Scholar]
  • 39. Rehani MM, Vano E, Ciraj-Bjelac O, Kleiman NJ.. Radiation and cataract. Radiat Prot Dosimetry 2011; 147: 300–304. [DOI] [PubMed] [Google Scholar]
  • 40. Matsubara K, Lertsuwunseri V, Srimahachota S, Krisanachinda A, Tulvatana W, Khambhiphant B, et al. Eye lens dosimetry and the study on radiation cataract in interventional cardiologists. Phys Med 2017; 44: 232–235. [DOI] [PubMed] [Google Scholar]
  • 41. Merriam GR, Focht EF.. A clinical and experimental study of the effect of single and divided doses of radiation on cataract production. Trans Am Ophthalmol Soc 1962; 60: 35–52. [PMC free article] [PubMed] [Google Scholar]
  • 42. Chylack LT Jr, Wolfe JK, Singer DM, Leske MC, Bullimore MA, Bailey IL, et al. The Lens Opacities Classification System III. The Longitudinal Study of Cataract Study Group. Arch Ophthalmol 1993; 111: 831–836. [DOI] [PubMed] [Google Scholar]
  • 43. Hamada N, Fujimichi Y, Iwasaki T, Fujii N, Furuhashi M, Kubo E, et al. Emerging issues in radiogenic cataracts and cardiovascular disease. J Radiat Res 2014; 55: 831–846. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 44. Andreassi MG, Piccaluga E, Guagliumi G, Del Greco M, Gaita F, Picano E.. Occupational health risks in cardiac catheterization laboratory workers. Circulation: Cardiovascular Interventions 2016; 9: e003273. [DOI] [PubMed] [Google Scholar]
  • 45. Domienik-Andrzejewska J, Kałużny P, Piernik G, Jurewicz J.. Occupational exposure to ionizing radiation and lens opacity in interventional cardiologists. Int J Occup Med Environ Health 2019; 32: 663–675. [DOI] [PubMed] [Google Scholar]
  • 46. Karatasakis A, Brilakis HS, Danek BA, Karacsonyi J, Martinez-Parachini JR, Nguyen-Trong PJ, et al. Radiation-associated lens changes in the cardiac catheterization laboratory: results from the IC-CATARACT (CATaracts Attributed to RAdiation in the CaTh lab) study. Catheter Cardiovasc Interv 2018; 91: 647–654. [DOI] [PubMed] [Google Scholar]
  • 47. Milacic S. Risk of occupational radiation-induced cataract in medical workers. Med Lav 2009; 100: 178–186. [PubMed] [Google Scholar]
  • 48. Bitarafan Rajabi A, Noohi F, Hashemi H, Haghjoo M, Miraftab M, Yaghoobi N, et al. Ionizing radiation-induced cataract in interventional cardiology staff. Res Cardiovasc Med 2015; 4: e25148. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 49. Scheidemann-Wesp U, Gianicolo EAL, Cámara RJ, Wegener A, Buchner SE, Schwenn O, et al. Ionising radiation and lens opacities in interventional physicians: results of a German pilot study. J Radiol Prot 2019; 39: 1041–1059. [DOI] [PubMed] [Google Scholar]
  • 50. Vano E, Kleiman NJ, Duran A, Romano-Miller M, Rehani MM.. Radiation-associated lens opacities in catheterization personnel: results of a survey and direct assessments. J Vasc Interv Radiol 2013; 24: 197–204. [DOI] [PubMed] [Google Scholar]
  • 51. Yuan MK, Chien CW, Lee SK, Hsu NW, Chang SC, Chang SJ, et al. Health effects of medical radiation on cardiologists who perform cardiac catheterization. J Chin Med Assoc 2010; 73: 199–204. [DOI] [PubMed] [Google Scholar]

Articles from Saudi Medical Journal are provided here courtesy of Saudi Medical Journal