Abstract
Objectives
This systematic review aims to investigate the effect of different preparation designs on the marginal fit and fracture strength of ceramic occlusal veneers.
Materials and Methods
Based on the PICO question and the search terms, an electronic search was performed in Google Scholar, PubMed (MEDLINE), Scopus, Cochrane Library, Web of Science, Science Direct, Wiley, Ovid, and SAGE for articles published up to July 2022. After including English in vitro studies that evaluated posterior ceramic occlusal overlays at the posterior with ceramic restorations by following the PRISMA statement, the extracted data was tabulated. The methodological quality of the included studies was evaluated. Risk of bias assessment was done independently by two authors using the modified MINORS scale.
Results
About 3138 search results were screened, of which 22 were selected due to their titles. Twenty‐one full‐text articles were assessed for eligibility. Seventeen in‐vitro studies were finalized for the extraction of quantitative data. All 17 articles had a low risk of bias and were retained. The influencing items for evaluating the research were different in most studies; therefore, qualitative synthesis of the results was feasible. They generally included preparation design, material thickness, depth of preparation in the tooth, internal divergence angle, and finish line. Meta‐analysis was not done due to heterogeneity of preparation types and evaluation methods. Results revealed that fracture resistance of occlusal veneers is higher than normal mastication force, and it is sufficient to prepare the occlusal surface, use a self‐etching primer for bonding, and an acceptable minimum ceramic thickness. The marginal discrepancy of occlusal veneers is clinically acceptable. However, this systematic review faces some limitations due to the lack of in vivo studies, different preparation designs in included studies, different follow‐ups, and lack of comprehensive explanations in articles.
Conclusions
The preparation design of occlusal veneers influences both marginal adaptation and fracture resistance. Various preparation designs are proven to have clinically acceptable fracture strength and marginal adaptation.
Keywords: fracture strength, marginal integrity, occlusal veneers, preparation design
1. INTRODUCTION
Preserving tooth structure is the principal goal of restorative dentistry, and by increasing the need for conservative and esthetic tooth restorations, the demand for partial‐coverage ceramics restorations is increasing (Blatz, 2002; Falahchai, Babaee Hemmati, Neshandar Asli, & Rezaei, 2020).
Besides caries as the main reason for tooth structure loss, some other non‐caries lesions, including erosion, abfraction, attraction, and fracture, lead to teeth's hard tissue breaking down and are needed to receive restorations (McCaul et al., 2004; Nascimento et al., 2011). Moreover, developmental tooth malformation may also need construction to reshape the tooth for biological, functional, esthetic, or social reasons (Bhaskar, 1986).
Tooth destruction predominantly affects the occlusal surface and functional cusps (Demarco et al., 2011), which can impact occlusal vertical dimension, esthetics, jawbone relationship, and occlusal stability (Attin et al., 2012; Mack, 1997). It is critical for the longevity of teeth and restorations to preserve remnant tooth structure (Van Dijken & Hasselrot, 2010).
The fracture strength of the dental material is one of the essential criteria to raise the survival rate of conservative restoration (Falahchai, Babaee Hemmati, Neshandar Asli, & Rezaei, 2020).
In addition, with the advance of new and reliable adhesive bonding techniques (Van Dijken & Hasselrot, 2010) and dental materials, selecting conservative treatment modalities, including less invasive restorations rather than aggressive treatments, is preferable.
Some less invasive alternative treatments such as conservative and esthetic partial coverage have been used currently, including inlays (no cuspal coverage), onlays (coverage of a minimum of one cusp), and overlays (all‐cusp coverage; Felden et al., 1998). Also, novel occlusal veneers with a non‐retentive design are used to restore the function and morphology of a defective occlusal surface (Johnson et al., 2014; Tsitrou & Van Noort, 2008).
To treat severe dental erosion, more conservative alternatives such as ultrafine restorations adhesively cemented have been preferred to traditional onlays or total crowns in posterior teeth (Johnson et al., 2014; Tsitrou & Van Noort, 2008), some studies have suggested occlusal veneers as they have high fracture resistance (Sasse et al., 2015). As many conventional preparation designs remove sound tooth structure, occlusal veneers with less invasive designs are increasingly sought‐after.
A study by Albelasy et al. (2021) has shown that material type and restoration thickness affect fracture resistance of CAD/CAM overlays. Moreover, some literature has determined occlusal ceramic fractures as the most common reason for restoration failure (Felden et al., 1998; Krämer & Frankenberger, 2005), which is affected by preparation design, bonding techniques, and thickness of the all‐ceramic restoration (Lima et al., 2013; Sasse et al., 2015).
Besides fracture resistance, marginal fitness is another main factor affecting long‐term restoration success (Suarez et al., 2003). A marginal gap results in the dissolution of luting cement and may cause restoration failure in the long run (Gu & Kern, 2003). Lack of marginal adaptation increases cement dissolution, leading to microleakage, secondary caries, periodontitis, marginal discoloration, and pulpal inflammation in some cases (Beuer et al., 2009; Sener‐Yamaner et al., 2017). Clinically, a marginal gap between 50 and 120 μm has been deemed acceptable (Heintze, 2007; Suarez et al., 2003).
Preparation design is an essential factor impacting fracture resistance in all‐ceramic restorations, such as rounding off all sharp angles (Krämer & Frankenberger, 2005). Nowadays, preparation designs for all‐ceramic restorations are modifications of conventional cast metal restorations (Stappert et al., 2008). Ultrathin one‐step with no‐prep polymer infiltrated ceramic network (PICN) overlays have indicated very high longevity and success (Ahmed et al., 2022). According to available data, the effects of preparation designs for an overlay are limited (Falahchai, Babaee Hemmati, Neshandar Asli, & Rezaei, 2020). Therefore, in this systematic review, the effect of the preparation design has been evaluated.
A systematic review by Vagropoulou et al. (2018) has shown that ceramic fractures were one of the restorations' complications, followed by retention loss and porcelain chipping; however, the survival rate for crowns was 95.38%, and for inlays and onlays, 90.89% and 93.50%, respectively, for 5 years, which are very high. However, this systematic review is aimed to investigate the effect of preparation design on the marginal fit and fracture strength of occlusal veneers.
2. MATERIALS AND METHODS
This systematic review followed the Preferred Reporting Items for Systematic Reviews and Meta‐Analyses (PRISMA) guidelines (McInnes et al., 2018). The focused PICO (population, intervention, control, outcome) question was whether specific preparation designs affect marginal adaptation and fracture strength of posterior occlusal ceramic veneers. The population, intervention, and outcome were defined as follows: the population was posterior occlusal veneers; the intervention was preparation design, and the outcome measures were marginal adaptation and fracture strength.
An electronic literature search of articles until July 2022 was performed in Google Scholar, PubMed (MEDLINE), Scopus, Cochrane Library, Web of Science, Science Direct, Wiley, Ovid, and SAGE by using combinations of the following search terms: (preparation design OR tooth preparation OR dental preparation OR preparation type) AND (occlusal veneers OR overlay) AND (conventional ceramic restoration OR partial fixed dental prostheses OR inlay OR onlay OR partial crowns) AND (marginal adaptation OR marginal fit OR marginal gap OR marginal discrepancy OR marginal accuracy OR fracture resistance OR fracture strength OR bend strength OR fracture load OR fracture toughness OR flexural strength OR load to failure). Studies were selected by title and abstract according to the inclusion criteria. The eligibility criteria are listed in Table 1. Three independent reviewers (Arghavan Navadeh, Samin Sirous, and Saeedeh Ebrahimgol) initially screened the titles and abstracts of all potential matches, after which complete copies were retrieved and critically assessed according to the pre‐determined inclusion and exclusion criteria. The references of all selected articles were also manually searched for any other articles that may have been missed during the electronic search. Any disagreement regarding the eligibility of included studies was resolved by a fourth reviewer (Faezeh Atri). All relevant in vitro studies were included. (Figure 1) As all the included studies are in‐vitro, the statement on ethical approval, the “protection of human subjects and animals in research,” and informed consent are not indicated.
Table 1.
Eligibility criteria
| Inclusion criteria | Exclusion criteria |
|---|---|
| Studies evaluating occlusal overlays | Literature reviews |
| Studies in English | Composite restorations |
| In vitro studies | Crowns |
| Posterior restorations | Endocrowns |
| Ceramic restorations | Case reports, Finite element |
Figure 1.

Decision flowchart of systematic literature review
Data were extracted from the included studies and tabulated with the following information: authors, groups, specimen type, sample size, restoration material, occlusal reduction, finish line, evaluation method, and conclusion (Table 2).
Table 2.
Descriptive data of included studies
| Authors and year of publication | Groups | Specimen type | Sample size | Restoration material | Occlusal reduction | Finish line | Evaluation method | Conclusion |
|---|---|---|---|---|---|---|---|---|
| Johnson et al. (2014) |
1. 0.3 mm thickness MZ100 blocks 2. 0.6 mm thickness MZ100 3. 1.0 mm thickness MZ100 4. 0.3 mm thickness lava ultimate blocks 5. 0.6 mm thickness lava ultimate 6. 1 mm thickness Lava Ultimate |
Maxillary molars | 60 | Paradigm MZ100 OR Lava Ultimate blocks | Occlusal thicknesses of 0.3, 0.6, and 1.0 mm | Universal testing machine | Restoration thickness had no statistically significant effect on fracture strength | |
| Sasse et al. (2015) |
1. Solely within enamel (EN) 2. Within enamel and dentin (E.D.) 3. Enamel and dentin with composite resin filling (E.C.) subgroups (different thickness) 0.3–0.6 mm 0.5–0.8 mm 0.7–1.0 mm |
Intact molars | 24 per group (in each group 3 subgroups (n = 8) with 3 different ceramic thickness (0.3–0.6 mm, 0.5–0.8 mm, 0.7–1 mm) | Lithium disilicate ceramic blocks |
0.3–0.7 mm in the fissures + 0.6–1.0 mm at the cusps. An angle of 150 degrees was prepared between the cusps In group 3, the dentin core was reduced by 1.5 mm and a composite filling. |
Universal testing machine |
Only the group with 0.7 mm thickness in fissure, 1.0 mm at cusp survived cyclic loading without any damage. The occlusal ceramic veneers thickness had a statistically significant influence on fracture resistance. Suggestion: use a thickness of 0.7–1 mm for non‐retentive full‐coverage adhesively retained occlusal lithium disilicate ceramic restorations. |
|
| Albelasy et al. (2021) |
1. e.max CAD 2. Vita enamic 3. Lava ultimate Each group had Subgroups (Thickness) 1. 1 mm 2. 1.5 mm |
Intact maxillary molars | 84 | Lithium disilicate glass‐ceramic OR CAD/CAM resin composite OR polymer‐infiltrated ceramic | 4 mm reduction | Thermal cycle/Kolmogorov–Smirnov and Shapiro–Wilk tests | All the CAD/CAM restorations in both thicknesses exhibited fracture resistance higher than normal and parafunctional masticatory forces. | |
| Guess et al. (2013) |
1. Palatal Onlay Standard 2. Palatal Onlay Thin 3. Palatal Onlay Ultrathin 4. Onlay Standard 5. Onlay Thin 6. Onlay Ultrathin 7. Complete Veneer Standard 8. Complete Veneer Thin 9. Complete Veneer Ultrathin |
Intact human maxillary premolars | 144 (9 groups of 16 specimens) | Pressable lithium disilicate glass‐ceramic |
1. 2 mm palatal cusp reduction 2. 1 mm as above 3. 0.5 mm as above 4. 2 mm Buccal and palatal cusp reduction 5. 1 mm as above 6. 0.5 mm as above 7. Complete Veneer Standard: chamfer 0.8 mm Labial surface 8. Chamfer 0.6 mm Labial surface 9. Chamfer of 0.4 mm Labial surface |
Chamfer | Cyclic mechanical loading and simultaneous thermocycling in a mouth‐motion simulator |
No cracks or fracture failures during thermomechanical fatigue application. Group 7 showed higher mean fracture loads than palatal or occlusal onlays. Group 3 revealed higher fracture loads than complete veneers. Thin and ultrathin palatal and occlusal onlay in addition to complete veneer restorations failed predominantly because of extensive crack formation within the ceramic or cohesive fractures limited to the ceramic material. |
| Falahchai, Babaee Hemmati, Neshandar Asli, and Rezaei (2020) |
1. (O) anatomical occlusal reduction 2. (O.S.) anatomical occlusal reduction with round shoulder 3. (O.G.) anatomical occlusal reduction with central groove 4. (OSG) anatomical occlusal reduction with round shoulder and central groove 5. (C) control group |
Intact human maxillary first molars |
50 (10 per group) |
Zirconia‐reinforced lithium silicate |
Pulpal depth of 2.5 mm and a width equal to half of the intercuspal distance. Buccal and lingual margins in groups O.S. and OSG received preparation with 1 mm width. |
Groups O.S. and OSG received round shoulder |
Universal testing machine |
Group O showed significantly higher marginal adaptation than the group OSG, which had a more complex and more retentive preparation design. No significant difference in marginal adaptation of groups O, O.S., and O.G. |
| Falahchai, Babaee Hemmati, Neshandar Asli, and Neshandar Asli (2020) |
1. Occlusal reduction(O) 2. Occlusal reduction with rounded shoulder (O.S.) 3. Occlusal reduction with a central groove (O.G.) 4. Occlusal reduction with rounded shoulder and central groove (OSG) |
Intact human maxillary first molars | 40 (4 groups of 10) | Zirconia‐reinforced lithium silicate (ZLS) ceramic | 2.5 mm isthmus pulpal depth and a half of the inter‐cuspal distance width in the occlusal in groups 3 and 4. Occlusal prep for all cusps. 1 mm rounded shoulder prep in buccal and lingual margins in groups 2 and 4. | Rounded shoulder (for groups O.S. and OSG) | Video measuring machine for marginal gap measurement before and after cementation | Marginal gap size in group O was significantly smaller than that in group OSG. Gap size significantly increased in all groups after cementation. |
| Abu‐Izze et al. (2018) |
1. Vita Suprinity with 0.5 mm (ZLS.5) 2. Vita Suprinity with 1 mm thickness (ZLS1) 3. In Vita Enamic with 0.5 mm (PIC.5) 4. In Vita Enamic with 1 mm thickness (PIC1). |
Posterior teeth | 60 | Vita Zahnfabrik blocks | Simplified occlusal reduction corresponding to a lower second molar. Restorations were waxed in two occlusal thicknesses, 0.5 or 1.0 mm. |
Kaplan Meier statistic of the number of cycles until failure. 5000 cycles at 200 N, followed by 450 N cycles. Axial load was carried out with a 4 Hz frequency in Biocycle V2 equipment (Biopdi) |
ZLS.5 showed lower fatigue strength compared with PIC1, and PIC.5 and ZLS1 were similar. Restorations thickness increase reduced the concentrations of stresses on internal and external surfaces. Restorations thickness decreasing (less than 1 mm) has an impact on increasing its susceptibility to failure. |
|
| Ioannidis et al. (2019) |
1. 0.5 mm zirconia 2. 1.0 mm zirconia 3. 0.5 mm lithium disilicate ceramic 4. 1.0 mm lithium disilicate ceramic 5. 0.5 mm PICN 6. 1.0 mm PICN 7. 0.5 mm resin composite 8. 1.0 mm resin composite |
Human molars | 80 | Zirconia OR Lithium‐disilicate ceramic OR PICN OR Resin composite |
Circular butt joint margins of 0.8–1.0 mm width+ 1.3–1.8 mm occlusal reduction + 3.0–4.0 mm minimal abutment height Two different thicknesses: 0.5 mm (range 0.3−0.7 mm) OR 1.0 mm (range 0.8−1.2 mm). |
Universal testing machines thermo‐mechanically aged and then load applied | The differences of the load capacity bearing medians between the test and the control groups did not reach statistical significance for the 0.5 mm thick specimens. Within the 1.0 mm thickness groups, significant different medians were found. | |
| Gupta et al. (2021) |
1. Full crown (control) 2. Mesial‐occlusal‐distal‐facial onlay 3. Mesial‐occlusal‐distal‐lingual onlay 4. Overlay |
Human premolars | 32 | Zirconia |
G1. 1.5 mm depth cuts G2. 2 mm nonfunctional cusp reduction G3. 2 mm functional cusp reduction G4. 1 mm depth cuts |
Rounded shoulder | thermomechanical loading with thermocycling/scanning electron microscope analysis | None of the specimens failed due to fracture or indicated any microcrack at 100× and 150×. |
| Emam and A Aleem (2020) |
1. Lithium disilicate glass ceramics 2. Hybrid all‐ceramic material 3. Nano ceramic reinforced resin composite Subgroups (1). minimally occlusal veneer preparation (2). occlusal veneer preparation with marginal chamfer |
Intact maxillary first premolars |
60 (10 per subgroup) |
Lithium disilicate glass ceramics OR Hybrid all‐ceramic material OR Nano ceramic reinforced resin composite |
1 mm occlusal reduction, buccal and palatal margins approximately 5.0 mm from the CEJ |
Chamfer |
Vertical margin gap distance was measured by image analysis system For fracture resistance testing a computer‐controlled material testing machine |
No statistically significant difference |
| Angerame et al. (2019) |
1. Full‐coverage occlusal veneer 2. 1 mm cusp reduction with a marginal chamfer |
Intact human maxillary molars | 16 (2 groups of 8) | Lithium disilicate glass‐ceramic | 1‐mm cusp reduction |
G1. Rounded 90° shoulder G2. chamfer |
Thermomechanical aging with a chewing simulator/scanning electron microscope analysis | No differences between the two groups in fracture load, fracture pattern, marginal quality, and internal fit. |
| Krummel et al. (2019) |
1. Enamel Prep (EN) 2. Dentin/enamel Prep (ED) 3. Enamel/composite resin filling (E.C.) Prep Each group had subgroups 1. Self‐etching primer (S.E.) 2. Additionally etched enamel (E.E.) |
Intact human molars | 48 (3 groups of 16) | Lithium disilicate ceramic |
Margins are in enamel in all Groups. 150 degrees angle between cusps. G1. 0.5 mm reduction G2. Prep extended into dentin G3. Prep extended into the dentin but the dentin core was 1.5 mm reduced and a composite filling |
Computerized dynamic load testing with integrated thermocycling/universal testing machine | Significantly higher mean fracture resistance in bonding with selective enamel etching in comparison with self‐etching primer only to enamel and dentin. No difference in bonding solely to enamel or to enamel and composite. | |
| Al‐Zordk et al. (2021) |
1. Lithium disilicate 2. Zirconia 3. Polymer‐infiltrated ceramic Each group had subgroups (bonding surface) 1. Dentin 2. Dentin with intra‐coronal cavity 3. Dentin and composite filling |
Intact mandibular first molars | 90 (10 in each group) | lithium disilicate OR zirconia OR polymer‐infiltrated ceramic | 150° angle between cusps. 2 mm cusp reduction. 1 mm pulpal depth, 2 mm bucco‐lingual width, 1.6 mm away from marginal ridge at intra‐coronal cavities | Tapered round‐end diamond was used | Thermo‐cycler machine and dynamic load aging/Universal testing machine | Different bonding had no significant effect on fracture resistance. All various bonds showed higher fracture resistance than normal masticatory forces in molars |
| Baldissara et al. (2019) |
1. 0.5 mm Ceramic thickness 2. 0.8 mm Ceramic thickness 3. 1.2 mm Ceramic thickness |
Intact human maxillary and mandibular molars | 60 (3 groups of 20) | Lithium disilicate | Occlusal surfaces were sectioned using a rotary diamond blade | Ball mill machine as a simplified fatigue testing machine | Restoration thickness had significant effects on survival rate and fracture (thicker restorations showed higher survival rate and less fracture). | |
| Huang et al. (2020) |
1. Occlusal surface coverage (O) 2. Occlusal and lingual surface coverage (OF) 3. Occlusal, lingual, and mesial surface coverage (POF) 4. Occlusal, lingual, mesial, and distal surface coverage (POFP) 5. Full crown |
Intact human maxillary premolars |
40 (8 per group) |
Lithium disilicate glass ceramic |
1. 0.7–1.0 mm occlusal 2. Same as group 1 + 0.5–1.0 mm lingual 3. Same as group 2 + 0.5–1.0 mm mesial 4. Same as group 3 + 0.5–1.0 mm distal 5. Same as group 4 + 0.5–1.0 mm buccal |
0.5‐mm‐thick marginal chamfer | Universal testing machine | As the number of restored axial walls increased, the fracture resistance decreased, and the maximum principal stress in the restoration increased. Minimally invasive preparation is recommended. |
| De Jesus Tavarez et al. (2014) |
1. Control, healthy unrestored teeth 2. Teeth restored with ceramic fragments 3. Teeth restored with ceramic overlays |
Intact maxillary premolars |
30 (10 per group) |
Feldspathic ceramic |
1. No prep 2. Unprepared restored with 1 mm ceramic 3. Extracoronal prep restored with 1 mm overlays 2 mm occlusal box, one third of the intercuspal distance, 1.5 mm proximal box, and a 2 mm gingival wall from the pulpal wall |
Universal testing machine | The teeth in G2 and G3 presented with type II fractures that involved a small portion of the coronal tooth structure and cohesive failure. G1 presented with more extensive fractures involving the root. G2 may offer greater resistance to fractures compared to G3. | |
| Stappert et al. (2005) |
|
Intact human maxillary premolars | 80 (5 groups of 16 specimens) | Pressed ceramic |
G1. No prep G2. 3 mm deep occlusal box and a 2 mm isthmus. The proximal boxes ended 1 mm short of CEJ G3. 2 mm palatal cusps reduction and following basic prep G4. 2 mm buccal cusps reduction G5. Basic prep and 0.8 mm facial chamfer |
Chamfer | Computer‐controlled masticatory simulation and fracture load testing | All specimens survived dynamic loading. The fracture load values of the unprepared teeth and those prepared for inlays and complete veneers were significantly higher than those of which cusps had been reduced in preparation for a partial coverage restoration. |
2.1. Quality assessment
Each included study was evaluated by three reviewers (Arghavan Navadeh, Samin Sirous, and Saeedeh Ebrahimgol) independently for the methodological quality, according to the following criteria: clearly stated aim, contemporary groups, clearly stated preparation method, baseline similarity of groups, randomization of specimens, clearly stated evaluation method (marginal gap/strength), blinding of the examiner, sample size calculation and power analysis, and adequate statistical analyses. The items were scored on a scale of 0–2; 0 if not reported; 1 when reported but inadequate; and 2 when reported and adequate. The overall score was considered from 18 for each study, and the articles were classified as high (0–6), medium (7–12), and low risk (13–18) of bias based on their score (Table 3).
Table 3.
Authors' judgments about risk of bias for each included study
| Authors and year of publication | Clearly stated aim | Contemporary groups | Baseline similarity of groups | Randomization of specimens | Clearly stated preparation method | Clearly stated evaluation method (marginal gap/strength) | Blinding of the examiner | Sample size calculation and power analysis | Adequate statistical analyses | Total score | Risk of bias |
|---|---|---|---|---|---|---|---|---|---|---|---|
| Johnson et al. (2014) | 2 | 2 | 2 | 2 | 1 | 2 | 2 | 2 | 2 | 17 | Low |
| Sasse et al. (2015) | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 18 | Low |
| Albelasy et al. (2021) | 2 | 2 | 2 | 2 | 1 | 2 | 2 | 2 | 2 | 17 | Low |
| Guess et al. (2013) | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 18 | Low |
| Falahchai, Babaee Hemmati, Neshandar Asli, and Rezaei (2020) | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 18 | Low |
| Falahchai, Babaee Hemmati, Neshandar Asli, and Neshandar Asli (2020) | 2 | 2 | 2 | 2 | 1 | 2 | 2 | 2 | 2 | 17 | Low |
| Abu‐Izze et al. (2018) | 2 | 2 | 1 | 2 | 1 | 2 | 2 | 2 | 2 | 16 | Low |
| Ioannidis, et al. (2019) | 2 | 2 | 2 | 2 | 1 | 2 | 2 | 2 | 2 | 17 | Low |
| Gupta et al. (2021) | 2 | 2 | 2 | 2 | 1 | 2 | 2 | 2 | 2 | 17 | Low |
| Emam and A Aleem (2020) | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 18 | Low |
| Angerame et al. (2019) | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 18 | Low |
| Krummel et al. (2019) | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 17 | Low |
| Al‐Zordk et al. (2021) | 2 | 2 | 2 | 2 | 1 | 2 | 2 | 2 | 2 | 17 | Low |
| Baldissara et al., (2019) | 2 | 2 | 2 | 2 | 1 | 2 | 2 | 2 | 2 | 17 | Low |
| Huang et al. (2020) | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 18 | Low |
| De Jesus Tavarez et al. (2014) | 2 | 2 | 2 | 2 | 1 | 2 | 2 | 2 | 2 | 17 | Low |
| Stappert, et al. (2005) | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 18 | Low |
Note: The items are scored as follows: 0, not reported; 1, reported but not adequately; or 2, reported adequately.
3. RESULTS
3.1. Identification of studies
A total of 3138 search results were screened. By evaluating the abstracts, 22 articles were selected. Of the 22 articles, one study was eliminated due to lack of data; another one was excluded since the full text could not be retrieved, and two case reports and one finite element were eliminated. Therefore, 17 articles were selected for extracting the quantitative data. The results of data extraction for each study are presented in Table 2.
As there was no specific scale to assess study risk or quality, in this systematic review, two authors (Samin Sirous/Faezeh Atri) independently evaluated the risk of bias by using the modified MINORS scale, which is a methodological index for non‐randomized studies (Slim et al., 2003). Each item was scored between 0 and 2; 0 for not reported items; 1 when reported but inadequate; and 2 when both reported and adequate. 18 was the ideal score; if the study score was between 13 and 18, the authors determined it as low risk; 7–12 fell under medium risk, and scores lower than 6 were counted as high risk. As all the studies showed a low risk of bias, they were retained in the review (Table 3).
The included studies were in vitro. The specimens of studies varied from maxillary premolars (Guess et al., 2013), maxillary molars (Falahchai, Babaee Hemmati, Neshandar Asli, & Rezaei, 2020), or maxillary first molars (Falahchai, Babaee Hemmati, Neshandar Asli, & Neshandar Asli, 2020), and so on. However, in the study by Abu‐Izze et al. (2018), wherein specimens are simply described as posterior teeth, or in the study by Ioannidis et al. (2019), the tested teeth were mentioned as human molars (Table 2).
Falahchai, Babaee Hemmati, Neshandar Asli, and Rezaei (2020) and Falahchai, Babaee Hemmati, Neshandar Asli, and Neshandar Asli (2020) evaluated the marginal gap in the specimens, and Gupta et al. (2021), Emam and A Aleem (2020), and Angerame et al. (2019) assessed both marginal adaptation and fracture resistance of the specimens, and it is noteworthy that other articles studied fracture strength.
The influencing items for evaluating the research were different in most of the studies. In general, they are as follows: preparation design, material thickness, depth of preparation in the tooth (cavity depth), internal divergence angle, and finish line.
Meta‐analysis could not be calculated because of the heterogeneity of preparation types and evaluation methods.
Qualitative analysis of included studies came to the following results. The marginal discrepancy and fracture resistance of occlusal veneers of all preparation designs are clinically acceptable. The strength of occlusal veneers is higher than normal mastication force (Johnson et al., 2014), and it is sufficient to prepare only the occlusal surface, use a self‐etching primer for bonding, an acceptable minimum ceramic thickness, and as a conclusion, there is no need for extensive reduction.
4. DISCUSSION
This systematic review aimed to evaluate the effect of different aspects of preparation designs of occlusal veneers on marginal adaptation and fracture resistance. The analysis of related articles determined that different aspects could influence marginal adaptation and fracture strength. Since overlays are considered a less invasive technique in some cases for reconstructing teeth for mastication and esthetics, it is essential to evaluate which modification increases fracture strength and reduces the marginal gap. In the following section, we discussed related articles that present preparation modifications, including different dental bonding surfaces, number of axial surfaces, different occlusal thickness, type of finish line, and preparation design.
4.1. Different bonding surface (enamel or dentin)
The success of an occlusal overlay is affected by different factors, with bonding technique being one of them. The type of bonding and the type of dental surfaces involved influence the bond strength. Due to various conditions, there are different indications for each bonding technique. Sasse et al. (2015) reported that luting to dentin or composite yields significantly higher fracture strength than luting to enamel only. This is due to different bonding techniques, namely the use of self‐etching primer that increases dentin bond strength as opposed to the total‐etch technique, which is used in several other studies. However, another study by Krummel et al. (2019) proved that additional etching of enamel or total‐etch, that is, selective enamel etching increases fracture strength when compared to self‐etching primer when bonding to dentin and enamel. They proposed that the recent study's higher fracture strength in dentin could be due to the improvement of a newly developed so‐called universal bonding system. On the other hand, the study by Walid Al‐Zordk et al. (2021) has shown that the fracture resistance within veneers bonded to dentin, dentin with intra‐coronal cavity, and dentin with the composite filling was not significantly different. However, their fracture resistance is above human regular masticatory forces in molars. Also, by varying dental bonding surfaces, different overlays' materials have to be considered (Al‐Zordk et al., 2021).
4.2. Different thicknesses of cavity preparation
It is determined that overlays with various occlusal thicknesses could tolerate loads higher than human masticatory forces ranging from 585 to 880 N (Johnson et al., 2014). Although an increase in the occlusal thickness of overlay restorations can lead to higher fracture resistance, further reduction more than carious lesion or fracture to increase the occlusal thickness of the overlays is not recommended. In Albelasy's study, the thickness of both 1 and 1.5 mm occlusal veneers exhibited fracture resistance higher than functional and parafunctional masticatory forces (Albelasy et al., 2021). By evaluating the influence of restoration thickness on fracture resistance, Sasse et al. (2015) concluded that occlusal ceramic veneer thickness affects fracture resistance. They suggested a minimum thickness of 0.7–1 mm when using a self‐etching primer which can increase fracture resistance compared to thinner restorations. In another study by Abu‐Izze et al. (2018), 1‐mm hybrid ceramics achieved better results in the fatigue test compared with 0.5‐mm Zirconium‐reinforced lithium silicate restorations, the rise in the thickness of the restorations significantly decreased the concentrations of stresses on different internal and external surfaces, and the stress concentration of Zirconium‐reinforced lithium silicate at the adhesive interface was higher in comparison to hybrid ceramics. In Baldissara's study (Al‐Zordk et al., 2021), comparing different groups, 0.8 mm may be considered an acceptable compromise between fracture resistance and tooth reduction as a threshold value.
Also, Ioannidis et al. (2019) indicated both 0.5 and 1.0 mm thicknesses as suitable for minimally invasive lithium‐disilicate ceramic (IPS e.max Press), zirconia (Vita YZ H.T.), PICN (Vita Enamic), and resin composite (Lava ultimate) overlay restorations in the posterior area. In Guess et al.'s (2013) in vitro study, ceramic thickness did not influence the fracture strength of occlusal veneer restorations. As a result, 1‐ and 0.5‐mm preparation depth reduction did not impair fracture resistance of pressable lithium‐disilicate ceramic onlays. This might be because this study was conducted on premolar specimens rather than molars used in the other studies. In Johnson et al.'s (2014) study with Paradigm MZ100 or Lava Ultimate, where blocks were fabricated at minimal occlusal thicknesses of 0.3, 0.6, and 1.0 mm, the restoration thickness had no statistically significant effect on fracture resistance. This can probably be attributed to the fact that these materials contain composite, which has better survival under cyclic loading than conventional ceramic.
4.3. Number of involved axial surfaces
In terms of some preparation surfaces, overlays reveal a higher fracture resistance than normal mastication force. In most cases, adding axial surfaces to the preparation does not significantly improve fracture resistance. However, some full‐crown cases show higher load resistance than overlays. Huang et al. (2020) concluded that veneers with only occlusal surface coverage have higher fracture strength than those covering three or more surfaces; on the other hand, occlusal‐only and occlusal plus lingual surface coverage veneers exhibited higher fracture strength than full crowns. Conversely, Guess et al. (2013) revealed the highest load values in complete veneer preparations that included both the palatal and buccal premolar cusps and the labial surface, and in 2014 a study indicated that overlays have lower fracture strength than ceramic fragments restorations (De Jesus Tavarez et al., 2014). In 2005, Stappert et al. (2005) studied the effect of varying preparation designs on reliability and fracture resistance of partial coverage premolar restorations and concluded that complete veneers, including the facial and masticatory surfaces (buccal and palatal cusps), showed comparable fracture resistance to that of unprepared natural teeth and are, therefore, superior to veneers covering only the buccal and/or palatal cusps. In the study by Gupta et al. (2021) with 3Y‐zirconia restorations with strict bonding techniques, full or partial coverage are viable restorations. However, this study suggested to avoid occlusal contact on restorations margins.
4.4. Different preparation design and finish line (marginal gap)
The reviewed studies also proved a relationship between finish line design and marginal adaptation. Falahchai, Babaee Hemmati, Neshandar Asli, and Rezaei (2020) showed that overlays prepared most conservatively with an anatomical occlusal reduction yielded the highest fracture resistance compared with those that included a rounded shoulder preparation or/and a central groove. In another study, Falahchai, Babaee Hemmati, Neshandar Asli, and Neshandar Asli (2020) proved that more invasive preparation designs are not necessary as the marginal adaptation of veneers prepared with only an anatomical occlusal reduction showed minimum marginal gap as opposed to those including a rounded shoulder or/and central groove. In Angerame et al. (2019), teeth were prepared either with a rounded 90‐degree shoulder finish line or a minimally invasive chamfer, and both results were similarly satisfactory. Emam and A Aleem (2020) tested minimally invasive occlusal veneer preparations resembling occlusal erosion against occlusal veneer preparations with a marginal chamfer and found no statistically significant difference between marginal gap distances.
The above data indicates that the preparation of overlays influences the fracture strength and marginal integrity of restorations. However, a systematic review mainly including in vitro studies cannot give a high level of evidence since its results cannot be extrapolated to humans. Also, this review had limitations due to using different teeth (premolars vs. molars), differently used materials, measuring techniques, and location of the teeth in included studies, and lack of comprehensive explanations in articles. Quantitative data analyses are prevented due to the high heterogeneity of the included articles. Some parameters have been considered based on a few studies or even one, and various other factors are not evaluated in studies; therefore, results should be drawn cautiously, and further studies and especially clinical trials with long periods of follow‐up, are required to assess different modifications of overlay preparation design.
5. CONCLUSION
Within the limitations of this systematic review, and according to the findings, the following conclusions were drawn:
-
1.
The preparation design of overlays influences both marginal adaptation and fracture resistance.
-
2.
Various preparation designs can be used with occlusal veneers to safely restore posterior teeth as these restorations are proven to have clinically acceptable fracture strength and marginal adaptation.
-
3.
Fracture resistance of occlusal veneers is higher than the normal range of human masticatory force; therefore, aggressive preparation to increase the fracture resistance is not recommended.
AUTHOR CONTRIBUTIONS
Faezeh Atri proposed the study concept. Arghavan Navadeh, Samin Sirous, and Saeedeh Ebrahimgol searched and gathered the relevant articles and analyzed them, and then Faezeh Atri approved the final ones. All the authors contributed to article evaluation and manuscript writing. The final manuscript is approved by all authors.
CONFLICT OF INTEREST
The authors declare no conflict of interest.
Sirous, S. , Navadeh, A. , Ebrahimgol, S. , & Atri, F. (2022). Effect of preparation design on marginal adaptation and fracture strength of ceramic occlusal veneers: A systematic review. Clinical and Experimental Dental Research, 8, 1391–1403. 10.1002/cre2.653
DATA AVAILABILITY STATEMENT
The data that support the findings of this study are available from the corresponding author upon reasonable request.
REFERENCES
- Abu‐Izze, F. , Ramos, G. , Borges, A. , Anami, L. , & Bottino, M. (2018). Fatigue behavior of ultrafine tabletop ceramic restorations. Dental Materials, 34, 1401–1409. [DOI] [PubMed] [Google Scholar]
- Ahmed, M. A. , Al‐Qutaibi, A. Y. , Wille, S. , & Kern, M. (2022). Clinical outcomes and influence of material parameters on the behavior and survival rate of thin and ultrathin occlusal veneers: A systematic review. Journal of Prosthodontic Research . Advance online publication. 10.2186/jpr.JPR_D_21_00270 [DOI] [PubMed]
- Albelasy, E. , Hamama, H. H. , Tsoi, J. K. , & Mahmoud, S. H. (2021). Influence of material type, thickness and storage on fracture resistance of CAD/CAM occlusal veneers. Journal of the Mechanical Behavior of Biomedical Materials, 119, 104485. [DOI] [PubMed] [Google Scholar]
- Al‐Zordk, W. , Saudi, A. , Abdelkader, A. , Taher, M. , & Ghazy, M. (2021). Fracture resistance and failure mode of mandibular molar restored by occlusal veneer: Effect of material type and dental bonding surface. Materials, 14(21):6476. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Angerame, D. , De Biasi, M. , Agostinetto, M. , Franzò, A. , & Marchesi, G. (2019). Influence of preparation designs on marginal adaptation and failure load of full‐coverage occlusal veneers after thermomechanical aging simulation. Journal of Esthetic and Restorative Dentistry, 31, 280–289. [DOI] [PubMed] [Google Scholar]
- Attin, T. , Filli, T. , Imfeld, C. , & Schmidlin, P. R. (2012). Composite vertical bite reconstructions in eroded dentitions after 5·5 years: A case series. Journal of Oral Rehabilitation, 39, 73–79. [DOI] [PubMed] [Google Scholar]
- Baldissara, P. , Monaco, C. , Onofri, E. , Fonseca, R. G. , & Ciocca, L. (2019). Fatigue resistance of monolithic lithium disilicate occlusal veneers: A pilot study. Odontology/the Society of the Nippon Dental University, 107, 482–490. [DOI] [PubMed] [Google Scholar]
- Beuer, F. , Aggstaller, H. , Edelhoff, D. , Gernet, W. , & Sorensen, J. (2009). Marginal and internal fits of fixed dental prostheses zirconia retainers. Dental Materials, 25, 94–102. [DOI] [PubMed] [Google Scholar]
- Bhaskar, S. N. (1986). Synopsis of oral pathology (Vol. 99, p. 137). C.V. Mosby. [Google Scholar]
- Blatz, M. B. (2002). Long‐term clinical success of all‐ceramic posterior restorations. Quintessence International, 33, 415–426. [PubMed] [Google Scholar]
- De Jesus Tavarez, R. R. , Firoozmand, L. M. , Silva, M. B. , Malheiros, A. S. , & Bandéca, M. C. (2014). Overlays or ceramic fragments for tooth restoration: An analysis of fracture resistance. The Journal of Contemporary Dental Practice, 15, 56–60. [DOI] [PubMed] [Google Scholar]
- Demarco, F. F. , Meireles, S. S. , Sarmento, H. R. , Dantas, R. V. F. , Botero, T. , & Tarquinio, S. B. C. (2011). Erosion and abrasion on dental structures undergoing at‐home bleaching. Clinical, Cosmetic and Investigational Dentistry, 3, 45–52. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Emam, Z. N. , & A Aleem, N. A. (2020). Influence of different materials and preparation designs on marginal adaptation and fracture resistance of CAD/CAM fabricated occlusal veneers. Egyptian Dental Journal, 66, 439–452. [Google Scholar]
- Falahchai, M. , Babaee Hemmati, Y. , Neshandar Asli, H. , & Neshandar Asli, M. (2020). Marginal adaptation of zirconia‐reinforced lithium silicate overlays with different preparation designs. Journal of Esthetic and Restorative Dentistry, 32, 823–830. [DOI] [PubMed] [Google Scholar]
- Falahchai, M. , Babaee Hemmati, Y. , Neshandar Asli, H. , & Rezaei, E. (2020). Effect of tooth preparation design on fracture resistance of zirconia‐reinforced lithium silicate overlays. Journal of Prosthodontics, 29(7), 617–622. [DOI] [PubMed] [Google Scholar]
- Felden, A. , Schmalz, G. , Federlin, M. , & Hiller, K.‐A. (1998). Retrospective clinical investigation and survival analysis on ceramic inlays and partial ceramic crowns: Results up to 7 years. Clinical Oral Investigations, 2, 161–167. [DOI] [PubMed] [Google Scholar]
- Gu, X.‐H. , & Kern, M. (2003). Marginal discrepancies and leakage of all‐ceramic crowns: Influence of luting agents and aging conditions. The International Journal of Prosthodontics, 16(2), 109–116. [PubMed] [Google Scholar]
- Guess, P. C. , Schultheis, S. , Wolkewitz, M. , Zhang, Y. , & Strub, J. R. (2013). Influence of preparation design and ceramic thicknesses on fracture resistance and failure modes of premolar partial coverage restorations. Journal of Prosthetic Dentistry, 110, 264–273. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Gupta, S. , Abdulmajeed, A. , Donovan, T. , Boushell, L. , Bencharit, S. , & Sulaiman, T. A. (2021). Monolithic zirconia partial coverage restorations: An in vitro mastication simulation study. Journal of Prosthodontics, 30(1), 76–82. [DOI] [PubMed] [Google Scholar]
- Heintze, S. D. (2007). Systematic reviews: I. The correlation between laboratory tests on marginal quality and bond strength. II. The correlation between marginal quality and clinical outcome. The Journal of Adhesive Dentistry, 9(Suppl 1), 77–106. [PubMed] [Google Scholar]
- Huang, X. , Zou, L. , Yao, R. , Wu, S. , & Li, Y. (2020). Effect of preparation design on the fracture behavior of ceramic occlusal veneers in maxillary premolars. Journal of Dentistry, 97, 103346. [DOI] [PubMed] [Google Scholar]
- Ioannidis, A. , Mühlemann, S. , Özcan, M. , Hüsler, J. , Hämmerle, C. H. , & Benic, G. I. (2019). Ultra‐thin occlusal veneers bonded to enamel and made of ceramic or hybrid materials exhibit load‐bearing capacities not different from conventional restorations. Journal of the Mechanical Behavior of Biomedical Materials, 90, 433–440. [DOI] [PubMed] [Google Scholar]
- Johnson, A. C. , Versluis, A. , Tantbirojn, D. , & Ahuja, S. (2014). Fracture strength of CAD/CAM composite and composite‐ceramic occlusal veneers. Journal of Prosthodontic Research, 58, 107–114. [DOI] [PubMed] [Google Scholar]
- Krämer, N. , & Frankenberger, R. (2005). Clinical performance of bonded leucite‐reinforced glass ceramic inlays and onlays after eight years. Dental Materials, 21, 262–271. [DOI] [PubMed] [Google Scholar]
- Krummel, A. , Garling, A. , Sasse, M. , & Kern, M. (2019). Influence of bonding surface and bonding methods on the fracture resistance and survival rate of full‐coverage occlusal veneers made from lithium disilicate ceramic after cyclic loading. Dental Materials, 35, 1351–1359. [DOI] [PubMed] [Google Scholar]
- Lima, J. M. , Souza, A. C. O. , Anami, L. C. , Bottino, M. A. , Melo, R. M. , & Souza, R. O. (2013). Effects of thickness, processing technique, and cooling rate protocol on the flexural strength of a bilayer ceramic system. Dental Materials, 29, 1063–1072. [DOI] [PubMed] [Google Scholar]
- Mack, M. (1997). Facially generated occlusal vertical dimension. The Compendium of Continuing Education in Dentistry, 18, 1183–1186, 1188, 1190. [PubMed] [Google Scholar]
- McCaul, L. K. , Jenkins, W. M. , & Kay, E. J. (2004). The reasons for extraction of permanent teeth in Scotland: A 15‐year follow‐up study. British Dental Journal, 196, 639–643. [DOI] [PubMed] [Google Scholar]
- McInnes, M. D. F. , Moher, D. , Thombs, B. D. , McGrath, T. A. , Bossuyt, P. M. , Clifford, T. , Cohen, J. F. , Deeks, J. J. , Gatsonis, C. , Hooft, L. , Hunt, H. A. , Hyde, C. J. , Korevaar, D. A. , Leeflang, M. M. G. , Macaskill, P. , Reitsma, J. B. , Rodin, R. , Rutjes, A. W. S. , Salameh, J. P. , … Willis, B. H. (2018). Preferred reporting items for a systematic review and meta‐analysis of diagnostic test accuracy studies: The PRISMA‐DTA statement. Journal of the American Medical Association, 319, 388–396. [DOI] [PubMed] [Google Scholar]
- Nascimento, M. M. , Gordan, V. V. , Qvist, V. , Bader, J. D. , Rindal, D. B. , Williams, O. D. , Gewartowski, D. , Fellows, J. L. , Litaker, M. S. , & Gilbert, G. H. (2011). Restoration of noncarious tooth defects by dentists in The Dental Practice‐Based Research Network. Journal of the American Dental Association, 142(12), 1368–1375. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Sasse, M. , Krummel, A. , Klosa, K. , & Kern, M. (2015). Influence of restoration thickness and dental bonding surface on the fracture resistance of full‐coverage occlusal veneers made from lithium disilicate ceramic. Dental Materials, 31, 907–915. [DOI] [PubMed] [Google Scholar]
- Sener‐Yamaner, I. D. , Sertgöz, A. , Toz‐Akalın, T. , & Özcan, M. (2017). Effect of material and fabrication technique on marginal fit and fracture resistance of adhesively luted inlays made of CAD/CAM ceramics and hybrid materials. Journal of Adhesion Science and Technology, 31, 55–70. [Google Scholar]
- Slim, K. , Nini, E. , Forestier, D. , Kwiatkowski, F. , Panis, Y. , & Chipponi, J. (2003). Methodological index for non‐randomized studies (MINORS): Development and validation of a new instrument. ANZ Journal of Surgery, 73, 712–716. [DOI] [PubMed] [Google Scholar]
- Stappert, C. F. , Abe, P. , Kurths, V. , Gerds, T. , & Strub, J. R. (2008). Masticatory fatigue, fracture resistance, and marginal discrepancy of ceramic partial crowns with and without coverage of compromised cusps. The Journal of Adhesive Dentistry, 10(1), 41–48. [PubMed] [Google Scholar]
- Stappert, C. F. J. , Guess, P. C. , Gerds, T. , & Strub, J. R. (2005). All‐ceramic partial coverage premolar restorations. Cavity preparation design, reliability and fracture resistance after fatigue. American Journal of Dentistry, 18, 275–280. [PubMed] [Google Scholar]
- Suarez, M. J. , Villaumbrosia, D. , González, P. , Pradíes, G. , & Lozano, J. F. (2003). Comparison of the marginal fit of Procera AllCeram Crowns with two finish lines. The International Journal of Prosthodontics, 16(3), 229–232. [PubMed] [Google Scholar]
- Tsitrou, E. , & Van Noort, R. (2008). Minimal preparation designs for single posterior indirect prostheses with the use of the Cerec system. International Journal of Computerized Dentistry, 11, 227–240. [PubMed] [Google Scholar]
- Vagropoulou, G. I. , Klifopoulou, G. L. , Vlahou, S. G. , Hirayama, H. , & Michalakis, K. (2018). Complications and survival rates of inlays and onlays vs complete coverage restorations: A systematic review and analysis of studies. Journal of Oral Rehabilitation, 45(11), 903–920. [DOI] [PubMed] [Google Scholar]
- Van Dijken, J. W. , & Hasselrot, L. (2010). A prospective 15‐year evaluation of extensive dentin–enamel‐bonded pressed ceramic coverages. Dental Materials, 26, 929–939. [DOI] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Data Availability Statement
The data that support the findings of this study are available from the corresponding author upon reasonable request.
