Volumetric microsampling for simultaneous remote immunosuppressant and kidney function monitoring in outpatient kidney transplant recipients

Tom C Zwart 1, Erik Metscher 1, Paul J M van der Boog 2,3, Jesse J Swen 1, Johan W de Fijter 2,3, Henk‐Jan Guchelaar 1, Aiko P J de Vries 2,3, Dirk Jan A R Moes 1,
PMCID: PMC9796409  PMID: 35670960

Abstract

Aims

Immunosuppressant and kidney function monitoring are crucial for kidney transplant recipient follow‐up. Microsamples enable remote sampling and minimise patient burden as compared to conventional venous sampling at the clinic. We developed a liquid chromatography–tandem mass spectrometry assay to quantify tacrolimus, mycophenolic acid (MPA), creatinine and iohexol in dried blood spot (DBS), and volumetric absorptive microsample (VAMS) samples.

Methods

The assay was successfully validated analytically for all analytes. Clinical validation was conducted by direct comparison of paired DBS, VAMS and venous reference samples from 25 kidney transplant recipients. Patients received iohexol 5–15 minutes before immunosuppressant intake and were sampled 0, 1, 2 and 3 hours thereafter, enabling tacrolimus and MPA area under the concentration–time curve (AUC) and creatinine‐based and iohexol‐based glomerular filtration rate (GFR) estimation. Method agreement was evaluated using Passing–Bablok regression, Bland–Altman analysis and the percentages of values within 15–30% of the reference (P15–P30) with a P20 acceptance threshold of 80%.

Results

For DBS samples, method agreement was excellent for tacrolimus trough concentrations (n = 25, P15 = 92.0%) and AUCs (n = 25; P20 = 95.8%) and adequate for creatinine‐based GFR trend monitoring (n = 25; P20 = 80%). DBS‐based MPA AUC assessment showed suboptimal agreement (n = 16; P20 = 68.8%), but was considered acceptable given its P30 of 100%. The assay performed inadequately for DBS‐based iohexol GFR determination (n = 24; P20 = 75%). The VAMS technique generally showed inferior performance, but can be considered for certain situations.

Conclusion

The assay was successfully validated for tacrolimus, MPA and creatinine quantification in DBS samples, enabling simultaneous remote kidney function trend monitoring and immunosuppressant therapeutic drug monitoring in kidney transplant recipients.

Keywords: immunosuppressants, kidney function, kidney transplantation, microsampling, therapeutic drug monitoring


1. What is already known about this subject

  • Microsampling techniques relying on capillary whole blood collection allow for remote blood sampling, providing a patient‐friendly and cost‐effective alternative to conventional venous sample collection at the clinic.

  • This has introduced options for remote blood collection for therapeutic drug monitoring purposes, including the monitoring of immunosuppressant exposure in kidney transplant recipients.

  • However, the application of these alternative sampling matrices in routine clinical care is still limited, but can probably be increased by addition of a kidney function marker leading to enhanced clinical feasibility.

What this study adds

  • A novel liquid chromatography tandem–mass spectrometry assay was developed and validated for the simultaneous quantification of tacrolimus, mycophenolate and creatinine in microsamples, enabling simultaneous remote immunosuppressant and kidney function monitoring.

  • Our study demonstrates that these analytes can be accurately and precisely quantified in dried blood spot, and, to a lesser extent, volumetric absorptive microsampling samples, and can pose a reliable alternative to conventional venous sampling at the clinic.

  • Finally, we show that microsampling‐based remote tacrolimus and mycophenolate therapeutic drug monitoring is feasible within routine clinical care, and propose options to further enhance the widespread implementation of this approach.

1. INTRODUCTION

The current guidelines on the clinical management of kidney transplant recipients recommend regular evaluation of graft function and immunosuppressant exposure. 1 This includes, amongst other markers, monitoring of the serum creatinine, estimated glomerular filtration rate (eGFR), and the immunosuppressant trough concentration (C0) and/or area under the concentration–time curve (AUC). Typically, these are determined during recurrent outpatient clinic visits, which can pose a patient burden in terms of time, travel costs and lost productivity.

Microsampling techniques relying on capillary whole blood collection via a finger prick, including dried blood spot (DBS) and volumetric absorptive microsample (VAMS) sampling, have introduced options for remote sampling and have gained interest as a patient‐friendly and cost‐effective 2 , 3 approach for monitoring kidney transplant recipients.

Various validation studies have been conducted for liquid chromatography–tandem mass spectrometry (LC–MS/MS) assays capable of quantifying tacrolimus, cyclosporine, everolimus, sirolimus and/or mycophenolic acid (MPA) in DBS, 2 , 4 , 5 , 6 , 7 , 8 , 9 , 10 , 11 , 12 , 13 , 14 , 15 , 16 , 17 , 18 , 19 , 20 , 21 , 22 , 23 , 24 , 25 , 26 , 27 , 28 , 29 , 30 , 31 , 32 , 33 VAMS, 34 , 35 , 36 , 37 , 38 , 39 , 40 , 41 , 42 , 43 , 44 , 45 or both. 46 , 47 , 48 Five of these assays allowed for the simultaneous quantification of 1 or more immunosuppressant and serum creatinine, 11 , 13 , 15 , 20 , 38 , 48 facilitating synchronised remote monitoring of kidney function and immunosuppressant exposure. However, the absence of MPA in these assays comprised an important limitation, as most kidney transplant recipients receive immunosuppressive therapy with tacrolimus, MPA and prednisolone. As therapeutic drug monitoring (TDM)‐guided dose adaptation is also recommended for MPA, 49 its inclusion in such multianalyte LC–MS/MS assays is important to advance the utility of remote microsampling‐based kidney transplant recipient monitoring. Furthermore, whereas the availability of such assays is important as a first step towards remote monitoring, subsequent clinical validation to demonstrate interchangeability with conventional venous sampling‐based methods is crucial before considering these methods for routine clinical care. Whereas such clinical validation studies with DBS and/or VAMS samples have been performed for tacrolimus, either alone 34 , 35 , 36 , 42 , 46 or in combination with MPA, 2 , 7 , 47 sirolimus, 16 cyclosporine, 19 , 40 creatinine, 20 , 38 , 48 or creatinine and cyclosporine, 13 and for everolimus, either alone 44 or in combination with sirolimus, 4 this is not the case for MPA and creatinine, let alone tacrolimus in combination with MPA and creatinine.

Additionally, while the eGFR comprises a convenient marker for kidney function trend monitoring, it shows limited agreement with measured GFR (mGFR)‐based techniques, which are considered to best resemble the true GFR. 50 , 51 , 52 Unfortunately, the available mGFR methods rely on extensive sampling, 50 , 53 which has hampered their application in routine care. Nevertheless, iohexol plasma clearance‐based mGFR assessment has gained interest for clinical and research purposes, 50 , 51 , 53 and also harnesses options for (partially) remote determination utilising microsampling. 54 , 55 , 56 , 57 , 58

Interestingly, the clinical potential of remote microsampling‐based kidney transplant recipient monitoring can be further enhanced with pharmacometric model‐based maximum a posteriori Bayesian estimation. This approach enables immunosuppressant AUC and iohexol mGFR estimation based on a limited number of aligned blood draws taken early after drug administration, 59 , 60 facilitating robust kidney function assessment and highly informative immunosuppressant TDM at limited patient discomfort.

Here, we developed and analytically validated a multiplex LC–MS/MS assay capable of simultaneously quantifying tacrolimus, MPA, sirolimus, everolimus, cyclosporine, creatinine and iohexol in volumetric DBS and VAMS samples. Subsequent clinical validation was performed for tacrolimus, MPA, everolimus, creatinine and iohexol based on direct comparison of paired DBS, VAMS and conventional venous whole blood samples from clinically stable kidney transplant recipients. Additionally, we evaluated the clinical feasibility of remote microsampling‐based immunosuppressant TDM in the kidney transplantation setting.

2. METHODS

2.1. Bioanalytical method development and validation

A novel multianalyte LC–MS/MS assay capable of quantifying tacrolimus, everolimus, sirolimus, cyclosporine, MPA, creatinine and iohexol simultaneously in DBS and VAMS samples was developed as per the European Medicines Agency guideline on bioanalytical method validation. 61 The method development was based on previously validated LC–MS/MS assays for these agents. 7 , 13 , 15 , 57 , 62 , 63 , 64 , 65

2.2. Clinical validation study

2.2.1. Study design

After the bioanalytical method development and validation, a clinical validation study was performed for tacrolimus, MPA, iohexol, creatinine and everolimus, by direct comparison of paired DBS, VAMS and venous EDTA reference samples.

2.2.2. Patients and samples

All data for the clinical validation study originated from participants of the RRFD trial (NTR7256). The RRFD trial aimed to include 100 clinically stable kidney(–pancreas) transplant recipients >1 year after transplantation with a creatinine clearance >25 mL/min/1.73 m2, receiving immunosuppressive therapy centred around once‐daily tacrolimus (Advagraf). The current study was performed in 25 RRFD participants and was approved by the Medical Ethical Committee of Leiden University Medical Center (LUMC; P16.170); all participants gave written informed consent.

At their final RRFD visit, each patient provided 4 sequential paired DBS, VAMS and venous EDTA samples, collected by a nurse practitioner just before (C0) and at 1, 2 and 3 hours after oral immunosuppressant intake. Iohexol (Omnipaque 300, GE Healthcare BV, Eindhoven, the Netherlands; containing 3235 mg iohexol) was administered intravenously 5–15 minutes before oral immunosuppressant intake. This schedule was selected to allow for blood draw alignment for population pharmacokinetic model‐based maximum a posteriori Bayesian estimation of the tacrolimus AUC0–24, MPA AUC0–12, everolimus AUC0–12 and the iohexol mGFR.

Capillary access for DBS and VAMS sample collection was acquired via a finger prick. Before sampling, the fingertip was cleaned with water, dried and punctured using a safety lancet (Sarstedt, Nümbrecht, Germany). The first capillary blood drop was discarded. DBS samples were collected with the HemaXis DB10 device, which combines a microfluidic plate for volumetric blood sampling (10 μL) and a Whatman 903 protein saver card for blood collection (DBS System, Gland, Switzerland). 66 VAMS samples were collected with the Mitra Clamshell device (Neotyrex, Torrance, CA, USA; 20 μL). 67 Venous access for EDTA sample collection was acquired using a standard cannulation procedure. Before analysis, all DBS and VAMS samples were inspected by a laboratory technician to ensure sample quality. Any analyte concentrations exceeding the established upper limits of quantification of the assay were diluted and then re‐analysed.

2.2.3. EDTA bioanalytical reference assays

Tacrolimus, MPA and everolimus were quantified in the venous EDTA reference samples using a previously validated multianalyte LC–MS/MS assay, 7 , 68 and iohexol with a previously validated HPLC‐UV assay. 60 Creatinine was quantified on a Cobas 8000 instrument (Roche, Almere, The Netherlands), using a standard creatininase–sarcosine enzymatic assay utilised for routine patient care at the LUMC clinical chemistry laboratory (validated concentration range: 44.5–884 μmol/L, <2% coefficient of variation [CV]).

2.3. Clinical feasibility study

Whereas demonstration of adequate analytical performance of the developed assay comprised our main focus, its clinical potential also depends of adequate patient satisfaction with and clinical feasibility of these alternative sampling devices.

Patient satisfaction was evaluated in the clinical validation study population (n = 25) using the System Usability Scale (SUS), a previously validated questionnaire to assess end‐user satisfaction with a given device. 69 The SUS comprises 10 question items which are scored on a 5‐point Likert scale, ranging from 1 (‘strongly disagree’) to 5 (‘strongly agree’). 69 The score contribution of question items 1, 3, 5, 7 and 9 is their scale position minus 1 point, whereas items 2, 4, 6, 8 and 10 contribute 5 points minus their scale position. 69 The item scores are summed and multiplied by 2.5 to yield the total SUS score, ranging from 0–100 with higher scores indicating higher system usability. 69

Additionally, we evaluated the clinical feasibility of the remote DBS‐based immunosuppressant TDM process based on historic DBS tacrolimus and MPA TDM measurements from kidney transplant recipients, performed as part of routine clinical care at LUMC. Remote DBS‐based tacrolimus and MPA TDM has been routinely applied at LUMC since its successful validation in 2018. 7 In short, patients are provided with a practical, written and visual instruction of the sampling procedure at the clinic. Patients then perform the blood collection for subsequent TDM instances remotely and send their DBS kit to our laboratory. A complete DBS kit contains 4 sequential samples and a form with the times of drug intake and sample collection. Before analysis, each kit is inspected by a laboratory technician who registers any anomalies. For this feasibility study, we extracted the laboratory data of all DBS kits received between April and September 2021, evaluated the percentage of clinically applicable DBS kits, and investigated any anomalies.

2.4. Statistics and software

Method comparison between the DBS, VAMS and reference samples was conducted for the individual tacrolimus, MPA and everolimus concentrations, AUCs, and AUC‐based daily dosing recommendations. Similarly, iohexol concentrations were compared individually and on the mGFR level. As the creatinine concentrations were quantified in 4‐fold, these were averaged across the 4 DBS or VAMS samples before comparison with the EDTA creatinine concentrations and eGFRs, as calculated using the CKD‐EPI formula. 70 To investigate the utility of the assay for combined tacrolimus C0 TDM and kidney function monitoring from 1 blood sample, the variability of the creatinine values across the 4 samples was also assessed.

Additionally, the physiological differences between capillary whole blood and venous EDTA plasma or serum and, to a lesser extent, venous EDTA whole blood may dictate the need for a conversion factor to translate drug concentrations quantified in DBS or VAMS samples to their corresponding venous EDTA concentrations to ensure correct clinical interpretation. Namely, for analytes that are normally quantified in venous EDTA plasma or serum, the presence of erythrocytes in a capillary whole blood sample yields a dilution effect, typically resulting in lower concentrations than observed in the corresponding venous EDTA sample. We anticipated that this phenomenon would be most pronounced for MPA and iohexol as these analytes are typically quantified in venous EDTA plasma and display negligible erythrocyte partitioning. 71 , 72 In this case, the dilution effect is approximated by the ratio between the erythrocyte volume and the total blood volume in the sample, which equals the blood haematocrit. By contrast, tacrolimus, 73 sirolimus, 74 cyclosporine, 75 everolimus 76 and creatinine 77 display extensive erythrocyte partitioning and were thus not expected to require concentration conversion. Several methods can be used for the concentration conversion, including individual or mean population haematocrit‐based conversion, mean concentration ratio‐based conversion, and conversion based on the Passing–Bablok regression fit. 7 For MPA, we previously demonstrated that a mean concentration ratio‐based conversion factor of 1/0.68 can be used to translate capillary whole blood concentrations to EDTA plasma concentrations. 7 This factor was thus also applied in the current study. For iohexol, we investigated the applicability of a similar ratio‐based conversion method, in addition to individual and population haematocrit‐based conversion.

For the method comparison, linearity and bias between the methods were evaluated using Passing–Bablok regression 78 and Bland–Altman plots. 79 Herein, Passing–Bablok regression allows for evaluation of the correlation between the results of both methods, taking into account the variability in both the x and y dimension. 80 Bland–Altman plots visualise the absolute, relative or ratio bias between the results of both methods over their mean concentration range, allowing for inspection of the mean bias, the variability of the bias and any trends of the bias over the concentration range. 80 Additionally, the percentages of samples falling within 15–30% (P15–P30) of the reference samples were evaluated. Herein the general acceptance threshold for method agreement was set at a P20 of 80%, whereas a more stringent P15 threshold of 80% was applied for tacrolimus C0 comparison. The latter threshold was derived from a similar validation study for tacrolimus quantification in microsamples. 46 Finally, a recent guideline on the bioanalytical method development of assays intended specifically for drug quantification in microsamples recommended evaluation of any haematocrit‐dependencies on the performance of the assay. 80 We thus evaluated, for each analyte and matrix, whether the ratio difference between the methods displayed any haematocrit dependency.

For the feasibility data, the total SUS scores for the DBS and VAMS devices were compared using a Wilcoxon signed rank test (α = 0.05). 81

Data handling, statistics and visualization were performed in R 3.6.2 (R Project for Statistical Computing, Vienna, Austria) and RStudio 1.2.5019 (RStudio Inc., Boston, MA, USA). The tacrolimus AUC0–24, MPA AUC0–12 and everolimus AUC0–12 were derived using maximum a posteriori Bayesian estimation based on their concentrations just before, and at 1, 2 and 3 hours after oral intake, using validated population pharmacokinetic models for these agents 82 , 83 , 84 , 85 translated for application in MW/Pharm. 86 Similarly, the iohexol mGFR was estimated based on the concentrations at 5–15 minutes, and at 1, 2 and 3 hours after intravenous administration, using a validated population pharmacokinetic model for iohexol mGFR determination in kidney transplant recipients 60 in NONMEM 7.4.4 (Icon Development Solutions, Ellicott City, MD, USA).

2.5. Nomenclature of targets and ligands

Key ligands in this article are hyperlinked to corresponding entries in http://www.guidetopharmacology.org, the common portal for data from the IUPHAR/BPS Guide to Pharmacology. 87

3. RESULTS

3.1. Bioanalytical method development and validation

The novel LC–MS/MS assay was successfully developed and validated bioanalytically. A detailed description of the technical aspects and bioanalytical validation is provided in the electronic supplementary material (ESM).

3.2. Clinical validation study

3.2.1. Patients and samples

Twenty‐five patients participated in this study, who provided a total of 97 blood samples. Their clinical characteristics are summarised in Table 1. For 1 patient, no venous samples could be obtained at 1, 2 and 3 hours due to unsuccessful cannulation.

TABLE 1.

Patient characteristics (n = 25)

Characteristic n (%) Mean Range
Sex
Male 18 (72%)
Female 7 (28%)
Age (y) 56.7 21.6–81.8
Total bodyweight (kg) 80.0 58.6–117
Transplant type
Kidney transplant 24 (96%)
Simultaneous kidney‐pancreas transplant 1 (4%)
Time after transplantation (y) 8.48 3.24–41.0
Haematocrit (fraction) 0.406 0.348–0.479
Immunosuppressive drug regimen
Tacrolimus + MPA + prednisolone 15 (60%)
Tacrolimus + prednisolone 4 (16%)
Tacrolimus + everolimus + prednisolone 3 (12%)
Tacrolimus + MPA 2 (8%)
Tacrolimus + azathioprine + prednisolone 1 (4%)

MPA, mycophenolic acid.

A full clinical validation was conducted for tacrolimus (97 concentrations; 24 AUCs), MPA (64 concentrations; 16 AUCs), creatinine (24 mean concentrations; 24 eGFRs) and iohexol (96 concentrations; 24 mGFRs), whereas the limited number of everolimus samples (12 concentrations; 3 AUCs) only allowed for an exploratory analysis. No patient samples containing sirolimus or cyclosporine could be obtained, thwarting clinical validation of the assay for these analytes.

3.2.2. Tacrolimus

For tacrolimus, the DBS and VAMS methods showed adequate linearity with the EDTA reference method, with Passing–Bablok regression slopes of 0.93 and 1.05 for the individual concentrations (Figure 1A, C) and 1.01 and 1.12 for the AUCs (Figure 1B, D), respectively (Table 2). The DBS method displayed mean biases of −6% (range: −25 to +19%) for the individual concentrations and −6% (range: −21 to +10%) for the AUCs, with P20 of 95.9 and 95.8%, respectively (Figure 2A, B; Table 2). The VAMS method showed slightly inferior performance, with mean biases of +7% (range: −24 to +37%) and +6% (range: −14 to +22%), and P20 of 76.3 and 79.2% for the individual concentrations and AUCs, respectively (Figure 2C, D; Table 2). Daily dosing recommendation of the DBS and VAMS methods differed from the reference values on 7/24 (29.2%) and 12/24 (50.0%) of occasions (Figure S2). Mean DBS dosing recommendations were 0.13 ± 0.30 mg (range: −0.5; +1.0) higher than for the reference (relative difference: +4.46% ± 9.62%, range: −6.67 to +33.3%). Those of the VAMS method were 0.19 ± 0.46 mg (range: −1.5; +0.5) lower than the reference (relative difference: −4.77% ± 9.31%, range: −25 to +14.3%).

FIGURE 1.

FIGURE 1

Passing–Bablok regression plots for the tacrolimus concentrations (A, C) and area under the concentration–time curves (AUCs; B, D), corrected mycophenolic acid (MPA) concentrations (E, G) and AUCs (F; H), creatinine concentrations (I, K) and estimated glomerular filtration rates (eGFRs; J, L), and corrected iohexol concentrations (M, O) and measured GFRs (mGFRs; N, P). Solid blue and gold lines represent the Passing–Bablok regression fits for the dried blood spot (DBS) and volumetric absorptive microsampling (VAMS) techniques, respectively, with their 95% confidence intervals shaded in grey

TABLE 2.

Agreement of the dried blood spot (DBS) and volumetric absorptive microsampling (VAMS) methods with the EDTA reference method

Analyte Marker Method n Passing–Bablok regression Bland–Altman ratio differences
Slope [95% CI] Intercept [95% CI] Mean ratio [95% LoA] P 20 (%) P 30 (%)
Tacrolimus Concentration DBS a 97 0.93 [0.89; 0.99] 0.01 [−0.36; 0.29] 0.94 [0.78; 1.11] 95.9 100
VAMS a 97 1.05 [0.98; 1.14] 0.14 [−0.37; 0.65] 1.07 [0.78; 1.35] 76.3 93.8
C0 DBS a 25 1.00 [0.82; 1.27] −0.27 [−1.44; 0.47] 0.95 [0.80; 1.10] 100 100
VAMS a 25 1.09 [0.88; 1.55] −0.06 [−2.31; 0.85] 1.07 [0.84; 1.31] 88.0 96.0
AUC0–24 DBS a 24 1.01 [0.87; 1.10] −11.4 [−24.6; 9.81] 0.94 [0.80; 1.08] 95.8 100
VAMS a 24 1.12 [0.92; 1.32] −4.69 [−34.3; 16.7] 1.06 [0.83; 1.30] 79.2 100
MPA Concentration DBS a 64 0.75 [0.70; 0.79] 0.01 [−0.14; 0.13] 0.75 [0.56; 0.95] 28.1 70.3
DBS b 64 1.10 [1.04; 1.15] 0.00 [−0.22; 0.17] 1.11 [0.82; 1.40] 78.1 85.9
VAMS a 64 0.72 [0.66; 0.77] 0.00 [−0.13; 0.14] 0.73 [0.52; 0.93] 17.2 57.8
VAMS b 64 1.07 [0.97; 1.13] 0.00 [−0.21; 0.18] 1.07 [0.77; 1.37] 84.4 93.8
AUC0–12 DBS b 16 1.14 [0.64; 1.38] −3.71 [−13.2; 13.9] 1.07 [0.79; 1.35] 68.8 100
VAMS b 16 1.11 [0.69; 1.35] −1.67 [−13.9; 13.8] 1.05 [0.76; 1.33] 87.5 93.8
Creatinine Mean concentration DBS a 25 1.13 [0.98; 1.37] −0.22 [−3.71; 2.02] 1.12 [0.94; 1.30] 76.0 100
VAMS a 25 1.17 [0.92; 1.71] −2.85 [−9.74; 0.93] 0.98 [0.76; 1.20] 92.0 100
eGFR DBS a 25 0.90 [0.75; 1.09] −0.88 [−10.0; 4.25] 0.88 [0.71; 1.05] 80.0 100
VAMS a 25 1.10 [0.88; 1.33] −4.12 [−15.9; 5.77] 1.04 [0.76; 1.33] 80.0 96.0
Iohexol Concentration DBS a 88 0.61 [0.55; 0.67] 1.24 [−7.05; 7.53] 0.61 [0.44; 0.79] 3.41 13.6
DBS b 88 1.01 [0.92; 1.11] −0.56 [−12.1; 10.2] 1.00 [0.72; 1.29] 85.2 92.0
VAMS a 88 0.61 [0.54; 0.67] 1.00 [−8.78; 11.2] 0.61 [0.39; 0.83] 5.68 25.0
VAMS b 88 1.01 [0.91; 1.11] −2.37 [−15.8; 14.8] 1.00 [0.64; 1.36] 76.1 88.6
mGFR DBS b 24 1.17 [0.88; 1.51] −9.34 [−30.2; 6.27] 1.01 [0.72; 1.29] 75.0 100
VAMS b 24 1.39 [0.82; 2.08] −20.5 [−66.1; 8.02] 1.02 [0.63; 1.40] 62.5 91.7

AUC0–12, area under the concentration–time curve from time zero to 12 h after administration; AUC0–24, area under the concentration–time curve from time zero to 24 h after administration; C0, trough concentration; CI, confidence interval; DBS, dried blood spot; eGFR, estimated glomerular filtration rate; LoA, limits of agreement; mGFR, measured glomerular filtration rate; MPA, mycophenolic acid; P20, percentage of observations within ±20% of those of the reference method; P30, percentage of observations within ±30% of those of the reference method; VAMS, volumetric absorptive microsample.

a

Based on the uncorrected concentration in capillary whole blood;

b

Based on the corrected concentration in capillary whole blood.

FIGURE 2.

FIGURE 2

Bland–Altman ratio difference plots for the tacrolimus concentrations (A, C) and area under the concentration–time curves (AUCs; B, D), corrected mycophenolic acid (MPA) concentrations (E, G) and AUCs (F, H), creatinine concentrations (I, K) and estimated glomerular filtration rates (eGFRs; J, L), and corrected iohexol concentrations (M, O) and measured GFRs (mGFRs; N, P). Solid and dotted blue and gold lines represent the mean bias and the lower and upper limits of agreement (LoA) for the dried blood spot (DBS) and volumetric absorptive microsampling (VAMS) techniques, respectively. The grey‐shaded area depicts the ±20% ratio difference limit around the line of identity, with any observations exceeding the ±20% ratio difference limit highlighted in red

A sub‐analysis with tacrolimus C0 samples exclusively (n = 25), displaying EDTA concentrations of 2.5–7.7 μg/L, showed excellent performance for the DBS samples with P15 and P20 of 92 and 100%, respectively (Table 2). By contrast, the VAMS samples showed inferior performance for C0 samples, with P15, P20 and P30 of 68, 88 and 96%.

Therefore, the tacrolimus C0 and AUC0–24 results quantified in DBS samples were interchangeable with those quantified in venous EDTA samples. The VAMS technique can be considered for tacrolimus AUC0–24 monitoring in clinically stable patients experiencing difficulties with the DBS technique, but should not be used for C0 monitoring based on a single sample.

3.2.3. MPA

As expected, the MPA, DBS and VAMS samples displayed a pronounced bias as compared to the reference EDTA plasma concentrations (Figures S3, S4), showing mean concentration ratios of 0.75 ± 0.10 (range: 0.56–0.98) and 0.73 ± 0.10 (range: 0.54–1.12), respectively. These suggest DBS‐to‐plasma and VAMS‐to‐plasma conversion factors of 1/0.75 and 1/0.73, which are slightly higher but comparable to the 1/0.68 observed in our previous study. 7

After correction with the 1/0.68 factor, the corrected DBS and VAMS MPA concentrations showed adequate linearity with the EDTA reference samples for the individual concentrations (Figure 1E, G) and AUCs (Figure 1F, H), displaying Passing–Bablok regression slopes of 1.10 and 1.07, and 1.14 and 1.11, respectively (Table 2). The DBS method showed biases of +11% (range: −18 to +44%) for the individual concentrations and +7% (range: −17 to +29%) for the AUCs, with P20 of 78.1 and 68.8%, respectively (Figure 2E, F; Table 2). Whereas the AUC P20 did not meet the prespecified acceptance criterium, its P25 and P30 of 93.8 and 100% did provide some reassurance of the potential of this approach.

The VAMS method showed superior performance, with mean biases of +7% (range: −21 to +64%) and +5% (range: −19 to +32%), and P20 of 84.4 and 87.5% for the individual concentrations and AUCs, respectively (Figure 2G, H; Table 2). The DBS and VAMS dosing recommendations were identical. For both methods, differences with the reference dosing recommendations occurred on 4/16 (25.0%) of occasions (Figure S2). On average, the DBS and VAMS dosing recommendations were 58.1 ± 190 mg (range: −500; +250) lower than for the reference (relative difference: −4.17% ± 14.6%, range: −33.3 to +25.0%).

Thus, the MPA AUC0–12 results quantified in VAMS samples were interchangeable with those quantified in venous plasma samples. The DBS technique yielded slightly different MPA AUC0–12 results, but can still be considered for routine clinical care as these differences were within 25% for most of the samples and did not exceed 30%.

3.2.4. Creatinine

For creatinine, the DBS and VAMS methods showed adequate linearity with the EDTA reference method across the eGFR range, with Passing–Bablok regression slopes of 1.13 and 1.17 for the individual concentrations (Figure 1I, K; Table 2) and 0.90 and 1.10 for the eGFRs (Figure 1J, L; Table 2), respectively. The DBS method yielded mean biases of +12% (range: −7 to +30%) for the individual concentrations and −12% (range: −27 to +9%) for the eGFRs, with P20 of 76.0 and 80.0%, respectively (Figure 2I, J; Table 2). The VAMS method showed superior performance, with mean biases of −2% (range: −22 to +24%) and +4% (range: −24 to +34%), and P20 of 92.0 and 80.0% of the individual concentrations and eGFRs, respectively (Figure 2K, L; Table 2).

Consistent with the superior overall precision for DBS samples observed during the analytical validation (ESM), the between‐sample creatinine concentration variability was lower within DBS kits (mean: 4.58 ± 2.76% CV, range: 0.93–13.7) than within VAMS kits (mean: 6.18 ± 3.44% CV, range: 2.48–14.4). The variability was <5% CV for 18/25 (72%) and <10% CV for 23/25 (92%) of patients for the DBS samples, whereas this was 13/25 (52%) and 21/25 (84%) for the VAMS samples.

Thus, when quantified in 4‐fold in tandem with immunosuppressant AUC assessment, the DBS or VAMS samples yielded eGFR results that are very similar to those quantified in venous EDTA samples and can be used for kidney function trend monitoring. Creatinine or eGFR assessment based on 1 sample is possible with the DBS technique, but not with the VAMS technique.

3.2.5. Iohexol

For iohexol, 8 samples (8.3%) drawn at 5–15 minutes after administration showed plasma concentrations >1000 mg/L, demonstrating divergent discrepancies with the DBS and VAMS samples. As iohexol concentrations >1000 mg/L were suspected to result from sampling errors, these samples were excluded from the analyses.

In the evaluation of the required DBS‐to‐plasma and VAMS‐to‐plasma conversion factors, the DBS and VAMS samples showed mean concentration ratios of 0.61 ± 0.09 (range: 0.36–0.84) and 0.61 ± 0.11 (range: 0.35–0.85) as compared to the EDTA plasma reference values (Figures S3, S4). This suggested a conversion factor of 1/0.61 for both matrices. Concentration conversion based on the mean population or individual haematocrit yielded comparable results, justifying the use of mean ratio‐based conversion for this study (Figure S5).

The corrected iohexol concentrations showed adequate linearity of the DBS and VAMS samples with the reference values for the individual concentrations (Figure 1M, O) and mGFRs (Figure 1N, P), displaying Passing–Bablok regression slopes of 1.01 and 1.01, and 1.17 and 1.39, respectively (Table 2). The DBS method showed biases of 0% (range: −41 to +38%) for the individual concentrations and +1% (range: −22 to +24%) for the mGFRs, with a P20 of 85.2 and 75.0%, respectively (Figure 2M, N; Table 2). The VAMS method showed inferior performance, with mean biases of +0% (range: −42 to +40%) and +2% (range: −31 to +37%), and a P20 of 76.1 and 62.5%, respectively (Figure 2O, P; Table 2).

Thus, the iohexol mGFR results quantified in DBS and, particularly, VAMS samples differed from those quantified in venous EDTA plasma. This renders our assay inapplicable for iohexol mGFR determination, because the clinical application of this approach calls for particularly high reliability.

3.2.6. Everolimus

For everolimus, albeit strictly exploratory owing to the limited sample size (n = 12), the DBS and VAMS methods showed adequate linearity with the EDTA reference method, with Passing–Bablok regression slopes of 0.95 and 1.13 for the individual concentrations (Figures S3, S4), respectively. On average, the DBS method showed superior results as compared to the VAMS method, yielding biases of −8% (range: −15 to +3%) vs. +21% (range: +12 to +38%), with a P20 of 100 and 50%, respectively (Figures S3, S4). The limited number of everolimus C0 (n = 3) and AUCs (n = 3) thwarted statistically sound method comparison. However, exploratory analyses did provide preliminary confirmation that the concentration results translate to similar C0 (DBS P15 = 100; VAMS P15 = 0%) and AUC (DBS P20 = 100; VAMS P20 = 33.3%) results.

Thus, these exploratory results suggested that our assay can be used for everolimus C0 and AUC0–12 TDM in DBS samples, but not in VAMS samples. However, additional validation is warranted to confirm this.

3.3. Clinical feasibility study

Complete SUS questionnaires were obtained from 20/25 (80%) of the included RRFD patients. The main results are depicted in Figure 3A, indicating adequate overall system usability for both devices, with median SUS scores of 65.0 (IQR: 52.5–72.5; range: 27.5–97.5) and 76.3 (IQR: 65.0–90.6; range: 35.0–100) for the DBS and VAMS devices, respectively. The VAMS device showed statistically significantly higher system usability than the DBS device (P = .013), with the difference originating mainly from question items on patient confidence with and ease‐of‐use of the devices (Figure 3B).

FIGURE 3.

FIGURE 3

Feasibility of volumetric microsampling in kidney transplant recipients as evaluated with the System Usability Score (SUS) questionnaire. (A) Boxplots of the total SUS scores for the dried blood spot (DBS) and volumetric absorptive microsampling (VAMS) methods. (B) Bar graph of the average score for each SUS questionnaire item for the DBS and VAMS methods

Laboratory data of 420 DBS kits from 341 unique patients were available for evaluation of the remote TDM process. Of these kits, 252 (60.0%) contained tacrolimus and MPA, 87 (20.7%) only tacrolimus, and 81 (19.3%) only MPA. This yielded 1611 DBS spots, of which 1463 spots (90.8%) were of adequate quality for quantification of the agent(s) of interest (Figure 4A). Of the 148 disapproved samples, 72 (48.6%) spots were discarded because no blood had been transferred from the capillary onto the filter paper, 38 (25.7%) contained a blood spot that was too small, 13 (8.8%) contained a blood spot that was too large, 13 (8.8%) spots were missing, 6 (4.1%) displayed blood spillage, 5 (3.4%) were sampled directly onto the filter paper and, for 1 spot (0.7%), no sampling time was recorded (Figure 4B). In total, 643 AUCs were anticipated from the 420 DBS kits, of which 591 (91.9%) could be estimated reliably (Figure 4C). Of the 52 failed AUCs, 44 (85%) AUCs could not be estimated due to disapproval of ≥2 blood spots. Additionally, 2 (3.8%) AUCs failed due to medication intake prior to the C0 sample collection, 2 (3.8%) because no clear peak concentration was reached, 1 (0.6%) because the C0 sample collection had failed, and 1 (0.6%) because only a C0 sample was collected. In 2 cases (3.8%), the device contained no blood spots at all (Figure 4D).

FIGURE 4.

FIGURE 4

Feasibility of the remote dried blood spot (DBS)‐based immunosuppressant therapeutic drug monitoring process. (A) Frequency of DBS spot disapproval. (B) Reasons for DBS spot disapproval. (C) Frequency of area under the concentration–time curve (AUC) failure. (D) Reasons for AUC failure

4. DISCUSSION

In this study, a novel LC–MS/MS assay was developed and clinically validated for the quantification of tacrolimus, MPA and creatinine in DBS and VAMS samples. Herewith, we aimed to enable simultaneous remote immunosuppressant TDM and kidney function assessment in kidney transplant recipients.

For tacrolimus, the assay showed high similarity between the DBS and reference samples with a P20 > 95% across the entire concentration and exposure range. While the Passing–Bablok regression analysis indicated a minor divergence between both methods, the Bland–Altman analysis and P20 results provided adequate assurance that the methods can be used interchangeably. Also, the developed assay showed adequate performance in the tacrolimus C0 range for DBS samples. Its P15 of 92.0% is comparable with a previously published multianalyte assay for tacrolimus C0 monitoring in kidney transplant recipients using DBS sampling, which displayed a P15 of 96.6%. 46 The VAMS method generally showed higher imprecision and P20 values just below the acceptance limit of 80%, but can be considered for AUC assessment in patients experiencing difficulties with the DBS device as most samples did fall within 30% of the reference. However, the P15 of 68.0% does not allow for VAMS‐based C0 monitoring.

For MPA, the assay showed moderate similarity of the corrected DBS and VAMS concentrations and AUCs with the plasma reference values. Notably, the DBS and VAMS samples displayed mean concentration ratios of 0.75 and 0.73 as compared to the plasma samples, respectively. Hence, mean ratio‐based conversion based on our previously derived factor of 1/0.68 7 resulted in slight overcorrection. Also, while the conversion factor corrects for the mean bias, it slightly inflates the overall imprecision, yielding broader limits of agreement around the mean bias. These findings may indicate a need for further optimization of our conversion factor. Previous studies have described various methods for DBS‐to‐plasma concentration conversion, including mean DBS‐to‐plasma ratio‐, 2 , 7 individual haematocrit‐ 5 , 10 , 47 and mean population haematocrit‐based 17 conversion. Disturbingly, a wide variability in the systematic DBS‐to‐plasma divergence is discernible between these studies, with Passing–Bablok slopes and mean concentration ratios ranging 0.51–0.78. 2 , 7 , 17 , 47 This translates to capillary DBS concentrations being generally 1.25‐ to 2‐fold lower than venous plasma concentrations. Whereas individual haematocrit‐based conversion seems the most sound approach from a theoretical perspective, the reported population haematocrits of 0.39–0.41 in these studies do to not fully explain the reported systematic biases. Clearly, this topic requires further study. Nevertheless, our VAMS method still showed a P20 of 87.5% in the AUC comparison, justifying clinical application of this method. Additionally, although the DBS method showed a P20 of merely 68.8%, its respective P25 and P30 of 93.8 and 100% in the AUC comparison provide reassurance that its performance is still acceptable for remote MPA AUC trend monitoring. This was confirmed by identical performance of the DBS and VAMS methods in the dosing recommendation comparison.

For creatinine, when quantified in 4‐fold in tandem with immunosuppressant AUC assessment, the assay showed adequate similarity of the DBS and VAMS methods with the reference method, with eGFR P20 values of 80% and P30 values >96%. The DBS method displayed a mean bias of −12% but relatively low imprecision, whereas the VAMS method showed negligible mean bias but higher imprecision. Particularly, the low analytical within‐ and between‐run imprecision (<4% CV; ESM) and low within‐kit variability for DBS samples ensures that detection of kidney function changes exceeding approximately 15% at adequate certainty. 88 Whereas this provides slightly less certainty than conventional monitoring at the clinic (<2% CV), the limited patient discomfort associated with remote microsampling facilitates more frequent eGFR assessment and thus trend monitoring at a higher resolution. By contrast, the inferior between‐run imprecision (ESM) and higher within‐kit variability for VAMS samples yields less reliable detection of kidney function changes over time with this technique, especially when quantified from 1 sample per occasion. Kidney function trend monitoring based on eGFR values quantified with our assay is thus preferably performed using the DBS technique.

For iohexol, the assay showed P20 values below the acceptance threshold for the DBS (P20 = 75.0%) and VAMS (P20 = 62.5%) methods in the mGFR comparison. Our assay should thus not be applied to inform stand‐alone clinical decisions based on iohexol mGFRs determined in microsamples. Also, while a clinically measured iohexol mGFR has added value over creatinine‐based approaches in terms of kidney function determination, 50 it is questionable whether this still holds true at suboptimal bioanalytical method performance. Especially because patients still need to come in for the intravenous iohexol administration, our microsampling‐based iohexol mGFR method has probably limited clinical potential at present. We suspected that the dissatisfactory results for iohexol were caused by variability in recovery, but this could not be confirmed based on our data. Aside from these aspects, the derived conversion factor of 1/0.61 requires further validation. Others have applied individual haematocrit‐based corrections, 55 , 56 , 71 , 89 , 90 but this necessitates quantification of the haematocrit in the DBS or VAMS sample when applied remotely. Whereas nondestructive techniques for haematocrit quantification in DBS samples exist, 91 , 92 these are not yet widely available. Also, while our mean ratio‐based conversion factor does not correct for the haematocrit dependency, the rather narrow haematocrit distribution in the stable kidney transplant recipient population probably does not result in clinically relevant bias. However, individual haematocrit correction does pose a more elegant approach and should be reconsidered when these techniques become more widely available. Finally, we encountered a number of iohexol concentrations >1000 mg/L for samples drawn within 5–15 minutes after iohexol administration, which were highly divergent from their paired DBS and VAMS concentrations. Although we suspected that these were associated with sampling errors, another explanation could be that capillary iohexol distribution was not yet complete at these early time points. In that case, Bayesian estimation of the iohexol mGFR based on DBS or VAMS samples may require slightly later time points for the first concentration.

For everolimus, albeit exploratory, the assay showed excellent performance for the DBS samples with a C0 and AUC P20 of 100%. By contrast, the VAMS samples showed C0 and AUC P20 results of 0 and 33%, respectively. Hence, the assay can probably be applied for routine everolimus quantification in DBS samples after additional validation, but requires further optimisation before considering its application for VAMS samples.

Thus, the developed assay allows for C0‐based tacrolimus TDM combined with creatinine and/or eGFR trend monitoring from a single DBS sample, but not from a single VAMS sample. Similarly, AUC‐based TDM for tacrolimus and/or MPA combined with creatinine and/or eGFR monitoring is preferably conducted with the DBS technique, based on blood samples drawn just before drug intake and at 1, 2 and 3 hours thereafter. The VAMS technique can be considered for tacrolimus and/or MPA AUC monitoring for patients experiencing difficulties with the DBS device, but yields less reliable detection of kidney function changes over time than the DBS technique. At present, our assay shows limited clinical potential for iohexol mGFR quantification in DBS or VAMS samples.

Overall, our assay generally showed higher imprecision for VAMS samples as compared to DBS samples. We suspect that this was related to higher variability in recovery for VAMS samples, as our initial DBS sample preparation method was only partly adjusted for VAMS samples. For instance, others have suggested to use an initial water:methanol ratio of 40:60 for the extraction solution to redissolve the erythrocytes, 43 whereas an initial ratio of 60:40 was applied here. This provides options to further optimise our assay for VAMS samples. Others have also suggested variability in sampling volume as an additional source of imprecision in VAMS samples, wherein particularly slightly undersaturated samples pose a problem as these cannot be identified by visual inspection. 46

Additionally, both microsampling devices demonstrated adequate patient satisfaction. Interestingly, a preference for the VAMS device over the DBS device was observed. This confirms that this sampling device has potential as an alternative to the DBS device for a selection of patients. The current remote TDM process showed adequate clinical feasibility, with successful DBS sample collection and clinical DBS kit applicability in >90% of cases. Nevertheless, some shortcomings were identified. Most sampling issues originated from incomplete blood transfer from the capillary to the filter paper. This is likely to be associated with incomplete or untimely closure of the device, indicative of a need for additional patient training and guidance. Additionally, in some cases, the blood spot volume was either too small or too large. Although the DBS device allows for volumetric blood sample collection, it requires complete filling of the capillary to produce an adequately sized spot. This can be a problem when the generated blood drop is too small to completely fill the capillary at once. Patients are allowed to apply multiple blood drops to completely fill the capillary; however, this may lead to blood coagulation within the capillary. Most issues with the clinical DBS kit applicability concerned disapproval of ≥2 spots, thereby thwarting reliable AUC estimation. Also, a few issues were related to the shape of the pharmacokinetic curve, including premature oral immunosuppressant intake and the absence of a clear peak concentration. The former indicates a need for improved patient instruction, whereas the latter is associated with the applied Bayesian estimator. While the selected Bayesian estimator is generally considered optimal for tacrolimus AUC estimation, 59 it apparently does not capture all pharmacokinetic profiles within this population. However, the limited number of divergent pharmacokinetic profiles does not justify extended sampling in the entire population. Finally, it is important to acknowledge that remote monitoring with these alternative sampling devices will simply not be operable for all patients. Already in our limited study population (n = 20), SUS scores ranged as low as 35, suggesting dissatisfaction with the device for certain patients. To identify these patients in a timely manner, it is important to evaluate the remote monitoring process early after initiation.

Our study showed some limitations. First, the clinical validation study was performed at the clinic where the participants were partly assisted with the sample collection. While this approach ensures high sample quality and accurate sampling time recording, it does not capture the remote sampling process. However, the results of our clinical feasibility study provide adequate reassurance of the potential of this novel assay. Second, the SUS questionnaire results may have partly been influenced by the differences in user experience with both devices. All participants had elaborate experience with the independent and remote use of the DBS device, but not with the VAMS device. Our findings are thus based on only a first impression of the VAMS device, do not include remote sampling experience with the VAMS device, and may have been partly influenced by the user's prior experiences with the DBS device. Third, no separate stability studies were performed for the VAMS samples during the analytical validation. However, previous studies have shown that tacrolimus, MPA and everolimus are stable in VAMS samples for 50 days in the freezer (−20°C), 60 days at room temperature, 30 days at 37°C and 2 days at 50°C. 43 Additionally, iohexol is stable in VAMS samples up to 8 months in the freezer (−20°C) or refrigerator (2–8°C) and 3 months at room temperature, 58 and creatinine for at least 14 days at 20°C, 7 days at 37°C and 25 days in the freezer (−20°C) or refrigerator (4°C). 38 As all VAMS samples for the clinical validation were analysed within 1 month after sample collection and stored at −20°C before analysis, no pronounced interference of analyte stability with our results was anticipated. Fourth, whereas we evaluated whether any haematocrit‐dependencies were discernible within the observed haematocrit range of the clinical validation population, linear regression‐based extrapolation of these data to more extreme haematocrit values is associated with uncertainty. However, our results are comparable with those from previous studies, which showed that tacrolimus, MPA, everolimus and creatinine can be quantified reliably in DBS samples displaying haematocrit values between 0.23 and 0.53, 12 , 15 while no such data are available for iohexol. Similarly, others showed that tacrolimus, MPA, everolimus, creatinine and iohexol can be quantified reliably in VAMS samples with haematocrit values between approximately 0.20 and 0.60. 43 , 48 , 58 As haematocrit values outside these ranges are seldomly encountered in adult kidney transplant recipients, 93 also in the clinically unstable phase, this probably allows for DBS‐ and VAMS‐based monitoring without pronounced haematocrit interference for most patients. Nevertheless, DBS‐ and VAMS‐based monitoring should still be considered carefully in the first weeks after transplantation and in otherwise clinically unstable patients, as these studies set their maximum tolerable haematocrit effect thresholds at ±15%, which still allows for substantial haematocrit‐dependent assay variability.

5. CONCLUSIONS

We developed and validated a novel LC–MS/MS assay for the simultaneous quantification of tacrolimus, MPA and creatinine in DBS and VAMS samples. Our DBS method allows for remote kidney function assessment combined with either tacrolimus and/or MPA AUC monitoring based on 4 sequential samples or tacrolimus C0 monitoring from a single sample. Furthermore, we demonstrated that remote DBS‐based immunosuppressant TDM is feasible within routine clinical care, offering a patient‐friendly alternative to conventional venous EDTA‐based TDM at the clinic. Our VAMS method has potential as an alternative to DBS sampling for a selection of patients, but generally yields less reliable results, demands more elaborate sample preparation and requires additional evaluation of the remote sampling process.

COMPETING INTERESTS

Tom Zwart, Erik Metscher, Paul van der Boog, Jesse Swen, Johan de Fijter, Henk‐Jan Guchelaar, Aiko de Vries and Dirk Jan Moes declare that they have no conflicts of interest that are directly relevant to the content of this article.

AUTHOR CONTRIBUTIONS

T.C.Z., P.J.M.v.d.B., A.P.J.d.V., H.J.G, .J.W.d.F and D.J.A.R.M. contributed to the study conception and design. T.C.Z., E.M. and D.J.A.R.M. performed the research and analysed the data. The initial draft of the manuscript was written by T.C.Z. and D.J.A.R.M., and all authors commented on previous versions of the manuscript. All authors read and approved the final version of the manuscript.

Supporting information

TABLE S1 Summary of the within‐run and between‐run accuracy and precision for all analytes.

TABLE S2 Summary of method agreement between the DBS, VAMS and reference methods, as evaluated during analytical cross‐validation.

TABLE S3 Estimated dried blood spot (DBS) and volumetric absorptive microsample (VAMS) to venous EDTA whole blood or plasma ratios over the haematocrit range, relative to their estimated ratios at the population mean haematocrit.

FIGURE S1 Observed dried blood spot (DBS) and volumetric absorptive microsample (VAMS) to venous EDTA whole blood or venous EDTA plasma ratios over the haematocrit (HCT) range. The solid blue and gold lines depict the linear regression line and the grey‐shaded areas its standard error. The linear regression equation is depicted for each analyte and matrix.

FIGURE S2 Daily dosing recommendations for (A) tacrolimus and (B) mycophenolic acid (MPA), based on the dried blood spot (DBS) and volumetric absorptive microsample (VAMS) area under the concentration–time curve (AUCs) as compared to those based on the corresponding reference AUCs. The dots are sized and coloured according to the number of patients (N) with a given daily dosing recommendation.

FIGURE S3 Passing–Bablok regression plots of the uncorrected mycophenolic acid (MPA; A, B), uncorrected iohexol (C, D), and exploratory everolimus (E, F) results. The solid blue and gold lines represent the Passing–Bablok regression fits for the dried blood spot (DBS) and volumetric absorptive microsampling (VAMS) methods, respectively.

FIGURE S4 Bland–Altman plots for the uncorrected mycophenolic acid (MPA; A, B), uncorrected iohexol (C, D) and exploratory everolimus results. Solid and dotted blue and gold lines represent the mean bias and the lower and upper limits of agreement (LoA) for the dried blood spot (DBS) and volumetric absorptive microsampling (VAMS) techniques, respectively. The grey‐shaded area depicts the ±20% ratio difference limit around the line of identity, with any observations exceeding the ±20% ratio difference limit highlighted in red.

FIGURE S5 Evaluation of the performance of the 3 conversion methods for translating iohexol concentrations in capillary whole blood to plasma concentrations, with the applied method highlighted in dark grey. Solid and dotted black lines represent the mean bias and the lower and upper limits of agreement (LoA). The grey‐shaded area depicts the ±20% ratio difference limit around the line of identity, with any observations exceeding the ±20% ratio difference limit highlighted in red. The dotted blue line and blue shaded area depict the linear regression line and its standard error.

ACKNOWLEDGEMENTS

The authors thank Martijn Koolen and Maaike Ferwerda for their exploratory work on the clinical feasibility study of this project, and appreciate the assistance of the staff of the Clinical Research Unit of the Department of Internal Medicine and the laboratory of the Department of Clinical Pharmacy and Toxicology of LUMC.

The bioanalytical validation for this article was supported by Sandoz [NL1909008662].

Zwart TC, Metscher E, van der Boog PJM, et al. Volumetric microsampling for simultaneous remote immunosuppressant and kidney function monitoring in outpatient kidney transplant recipients. Br J Clin Pharmacol. 2022;88(11):4854‐4869. doi: 10.1111/bcp.15433

The authors confirm that the Principal Investigator for this article is Dirk Jan Moes.

Funding information Sandoz, Grant/Award Number: NL1909008662

DATA AVAILABILITY STATEMENT

The datasets generated during and/or analysed during this study are available from the corresponding author upon reasonable request.

REFERENCES

  • 1. Kidney Disease: Improving Global Outcomes (KDIGO) Transplant Work Group . KDIGO clinical practice guideline for the care of kidney transplant recipients. Am J Transplant. 2009;9(3):S1‐S155. doi: 10.1111/j.1600-6143.2009.02834.x [DOI] [PubMed] [Google Scholar]
  • 2. Martial LC, Hoogtanders KEJ, Schreuder MF, et al. Dried blood spot sampling for tacrolimus and mycophenolic acid in children: analytical and clinical validation. Ther Drug Monit. 2017;39(4):412‐421. doi: 10.1097/FTD.0000000000000422 [DOI] [PubMed] [Google Scholar]
  • 3. Veenhof H, van Boven JFM, van der Voort A, Berger SP, Bakker SJL, Touw DJ. Effects, costs and implementation of monitoring kidney transplant patients' tacrolimus levels with dried blood spot sampling: A randomized controlled hybrid implementation trial. Br J Clin Pharmacol. 2020;86(7):1357‐1366. doi: 10.1111/bcp.14249 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 4. Veenhof H, Koster RA, Alffenaar JC, et al. Clinical application of a dried blood spot assay for sirolimus and everolimus in transplant patients. Clin Chem Lab Med. 2019;57(12):1854‐1862. doi: 10.1515/cclm-2019-0053 [DOI] [PubMed] [Google Scholar]
  • 5. Almardini R, Taybeh EO, Alsous MM, et al. A multiple methods approach to determine adherence with prescribed mycophenolate in children with kidney transplant. Br J Clin Pharmacol. 2019;85(7):1434‐1442. doi: 10.1111/bcp.13911 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 6. Leino AD, King EC, Jiang W, et al. Assessment of tacrolimus intrapatient variability in stable adherent transplant recipients: Establishing baseline values. Am J Transplant. 2019;19(5):1410‐1420. doi: 10.1111/ajt.15199 [DOI] [PubMed] [Google Scholar]
  • 7. Zwart TC, Gokoel SRM, van der Boog PJM, et al. Therapeutic drug monitoring of tacrolimus and mycophenolic acid in outpatient renal transplant recipients using a volumetric dried blood spot sampling device. Br J Clin Pharmacol. 2018;84(12):2889‐2902. doi: 10.1111/bcp.13755 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 8. Willemsen A, Knapen LM, de Beer YM, et al. Clinical validation study of dried blood spot for determining everolimus concentration in patients with cancer. Eur J Clin Pharmacol. 2018;74(4):465‐471. doi: 10.1007/s00228-017-2394-0 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 9. Knapen LM, Beer Y, Brüggemann RJM, et al. Development and validation of an analytical method using UPLC‐MS/MS to quantify everolimus in dried blood spots in the oncology setting. J Pharm Biomed Anal. 2018;149:106‐113. doi: 10.1016/j.jpba.2017.10.039 [DOI] [PubMed] [Google Scholar]
  • 10. Iboshi H, Yamaguchi H, Suzuki H, et al. Development of a liquid chromatography‐tandem mass spectrometric method for quantification of mycophenolic acid and its glucuronides in dried blood spot samples. Ther Drug Monit. 2017;39(6):648‐653. doi: 10.1097/FTD.0000000000000458 [DOI] [PubMed] [Google Scholar]
  • 11. al‐Uzri A, Freeman KA, Wade J, et al. Longitudinal study on the use of dried blood spots for home monitoring in children after kidney transplantation. Pediatr Transplant. 2017;21(6):e12983. doi: 10.1111/petr.12983 [DOI] [PubMed] [Google Scholar]
  • 12. Koster RA, Veenhof H, Botma R, et al. Dried blood spot validation of five immunosuppressants, without hematocrit correction, on two LC‐MS/MS systems. Bioanalysis. 2017;9(7):553‐563. doi: 10.4155/bio-2016-0296 [DOI] [PubMed] [Google Scholar]
  • 13. Veenhof H, Koster RA, Alffenaar JC, Berger SP, Bakker SJL, Touw DJ. Clinical validation of simultaneous analysis of tacrolimus, cyclosporine A, and creatinine in dried blood spots in kidney transplant patients. Transplantation. 2017;101(7):1727‐1733. doi: 10.1097/TP.0000000000001591 [DOI] [PubMed] [Google Scholar]
  • 14. Koster RA, Botma R, Greijdanus B, et al. The performance of five different dried blood spot cards for the analysis of six immunosuppressants. Bioanalysis. 2015;7(10):1225‐1235. doi: 10.4155/bio.15.63 [DOI] [PubMed] [Google Scholar]
  • 15. Koster RA, Greijdanus B, Alffenaar JW, Touw DJ. Dried blood spot analysis of creatinine with LC‐MS/MS in addition to immunosuppressants analysis. Anal Bioanal Chem. 2015;407(6):1585‐1594. doi: 10.1007/s00216-014-8415-2 [DOI] [PubMed] [Google Scholar]
  • 16. Dickerson JA, Sinkey M, Jacot K, et al. Tacrolimus and sirolimus in capillary dried blood spots allows for remote monitoring. Pediatr Transplant. 2015;19(1):101‐106. doi: 10.1111/petr.12392 [DOI] [PubMed] [Google Scholar]
  • 17. Arpini J, Antunes MV, Pacheco LS, et al. Clinical evaluation of a dried blood spot method for determination of mycophenolic acid in renal transplant patients. Clin Biochem. 2013;46(18):1905‐1908. doi: 10.1016/j.clinbiochem.2013.10.011 [DOI] [PubMed] [Google Scholar]
  • 18. Koster RA, Alffenaar JW, Greijdanus B, Uges DR. Fast LC‐MS/MS analysis of tacrolimus, sirolimus, everolimus and cyclosporin A in dried blood spots and the influence of the hematocrit and immunosuppressant concentration on recovery. Talanta. 2013;115:47‐54. doi: 10.1016/j.talanta.2013.04.027 [DOI] [PubMed] [Google Scholar]
  • 19. Hinchliffe E, Adaway J, Fildes J, Rowan A, Keevil BG. Therapeutic drug monitoring of ciclosporin A and tacrolimus in heart lung transplant patients using dried blood spots. Ann Clin Biochem. 2014;51(Pt 1):106‐109. doi: 10.1177/0004563213488759 [DOI] [PubMed] [Google Scholar]
  • 20. Koop DR, Bleyle LA, Munar M, Cherala G, Al‐Uzri A. Analysis of tacrolimus and creatinine from a single dried blood spot using liquid chromatography tandem mass spectrometry. J Chromatogr B Analyt Technol Biomed Life Sci. 2013;926:54‐61. doi: 10.1016/j.jchromb.2013.02.035 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 21. Sadilkova K, Busby B, Dickerson JA, Rutledge JC, Jack RM. Clinical validation and implementation of a multiplexed immunosuppressant assay in dried blood spots by LC‐MS/MS. Clin Chim Acta. 2013;421:152‐156. doi: 10.1016/j.cca.2013.02.009 [DOI] [PubMed] [Google Scholar]
  • 22. Wilhelm AJ, Klijn A, den Burger JC, et al. Clinical validation of dried blood spot sampling in therapeutic drug monitoring of ciclosporin A in allogeneic stem cell transplant recipients: direct comparison between capillary and venous sampling. Ther Drug Monit. 2013;35(1):92‐95. doi: 10.1097/FTD.0b013e31827d76ce [DOI] [PubMed] [Google Scholar]
  • 23. den Burger JC, Wilhelm AJ, Chahbouni A, Vos RM, Sinjewel A, Swart EL. Analysis of cyclosporin A, tacrolimus, sirolimus, and everolimus in dried blood spot samples using liquid chromatography tandem mass spectrometry. Anal Bioanal Chem. 2012;404(6–7):1803‐1811. doi: 10.1007/s00216-012-6317-8 [DOI] [PubMed] [Google Scholar]
  • 24. Li Q, Cao D, Huang Y, Xu H, Yu C, Li Z. Development and validation of a sensitive LC‐MS/MS method for determination of tacrolimus on dried blood spots. Biomed Chromatogr. 2013;27(3):327‐334. doi: 10.1002/bmc.2795 [DOI] [PubMed] [Google Scholar]
  • 25. Hinchliffe E, Adaway JE, Keevil BG. Simultaneous measurement of cyclosporin A and tacrolimus from dried blood spots by ultra high performance liquid chromatography tandem mass spectrometry. J Chromatogr B Analyt Technol Biomed Life Sci. 2012;883‐884:102‐107. doi: 10.1016/j.jchromb.2011.05.016 [DOI] [PubMed] [Google Scholar]
  • 26. Rao RN, Maurya PK, Ramesh M, Srinivas R, Agwane SB. Development of a validated high‐throughput LC‐ESI‐MS method for determination of sirolimus on dried blood spots. Biomed Chromatogr. 2010;24(12):1356‐1364. doi: 10.1002/bmc.1450 [DOI] [PubMed] [Google Scholar]
  • 27. Leichtle AB, Ceglarek U, Witzigmann H, Gäbel G, Thiery J, Fiedler GM. Potential of dried blood self‐sampling for cyclosporine c(2) monitoring in transplant outpatients. J Transplant. 2010;2010:201918. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 28. Wilhelm AJ, den Burger JC, Chahbouni A, Vos RM, Sinjewel A. Analysis of mycophenolic acid in dried blood spots using reversed phase high performance liquid chromatography. J Chromatogr B Analyt Technol Biomed Life Sci. 2009;877(30):3916‐3919. doi: 10.1016/j.jchromb.2009.09.037 [DOI] [PubMed] [Google Scholar]
  • 29. Wilhelm AJ, den Burger JC, Vos RM, Chahbouni A, Sinjewel A. Analysis of cyclosporin A in dried blood spots using liquid chromatography tandem mass spectrometry. J Chromatogr B Analyt Technol Biomed Life Sci. 2009;877(14–15):1595‐1598. doi: 10.1016/j.jchromb.2009.03.024 [DOI] [PubMed] [Google Scholar]
  • 30. van der Heijden J, de Beer Y, Hoogtanders K, et al. Therapeutic drug monitoring of everolimus using the dried blood spot method in combination with liquid chromatography‐mass spectrometry. J Pharm Biomed Anal. 2009;50(4):664‐670. doi: 10.1016/j.jpba.2008.11.021 [DOI] [PubMed] [Google Scholar]
  • 31. Cheung CY, van der Heijden J, Hoogtanders K, et al. Dried blood spot measurement: application in tacrolimus monitoring using limited sampling strategy and abbreviated AUC estimation. Transpl Int. 2008;21(2):140‐145. doi: 10.1111/j.1432-2277.2007.00584.x [DOI] [PubMed] [Google Scholar]
  • 32. Hoogtanders K, van der Heijden J, Christiaans M, van de Plas A, van Hooff J, Stolk L. Dried blood spot measurement of tacrolimus is promising for patient monitoring. Transplantation. 2007;83(2):237‐238. doi: 10.1097/01.tp.0000250730.30715.63 [DOI] [PubMed] [Google Scholar]
  • 33. Hoogtanders K, van der Heijden J, Christiaans M, Edelbroek P, van Hooff JP, Stolk LM. Therapeutic drug monitoring of tacrolimus with the dried blood spot method. J Pharm Biomed Anal. 2007;44(3):658‐664. doi: 10.1016/j.jpba.2006.11.023 [DOI] [PubMed] [Google Scholar]
  • 34. Kindem IA, Bjerre A, Åsberg A, Midtvedt K, Bergan S, Vethe NT. Tacrolimus measured in capillary volumetric microsamples in pediatric patients‐a cross‐validation Study. Ther Drug Monit. 2021;43(3):371‐375. doi: 10.1097/FTD.0000000000000873 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 35. Tron C, Ferrand‐Sorre MJ, Querzerho‐Raguideau J, et al. Volumetric absorptive microsampling for the quantification of tacrolimus in capillary blood by high performance liquid chromatography‐tandem mass spectrometry. J Chromatogr B Analyt Technol Biomed Life Sci. 2021;1165:122521. doi: 10.1016/j.jchromb.2020.122521 [DOI] [PubMed] [Google Scholar]
  • 36. Undre N, Dawson I, Aluvihare V, et al. Validation of a capillary dry blood sample MITRA‐based assay for the quantitative determination of systemic tacrolimus concentrations in transplant recipients. Ther Drug Monit. 2021;43(3):358‐363. doi: 10.1097/FTD.0000000000000847 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 37. Undre N, Hussain I, Meijer J, Stanta J, Swan G, Dawson I. Quantitation of tacrolimus in human whole blood samples using the MITRA microsampling device. Ther Drug Monit. 2021;43(3):364‐370. doi: 10.1097/FTD.0000000000000833 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 38. Marshall DJ, Kim JJ, Brand S, Bryne C, Keevil BG. Assessment of tacrolimus and creatinine concentration collected using Mitra microsampling devices. Ann Clin Biochem. 2020;57(5):389‐396. doi: 10.1177/0004563220948886 [DOI] [PubMed] [Google Scholar]
  • 39. Paniagua‐González L, Díaz‐Louzao C, Lendoiro E, et al. Volumetric absorptive microsampling (VAMS) for assaying immunosuppressants from venous whole blood by LC‐MS/MS using a novel atmospheric pressure ionization probe (UniSpray™). J Pharm Biomed Anal. 2020;189:113422. doi: 10.1016/j.jpba.2020.113422 [DOI] [PubMed] [Google Scholar]
  • 40. Mbughuni MM, Stevens MA, Langman LJ, et al. Volumetric microsampling of capillary blood spot vs whole blood sampling for therapeutic drug monitoring of tacrolimus and cyclosporin A: accuracy and patient satisfaction. J Appl Lab Med. 2020;5(3):516‐530. doi: 10.1093/jalm/jfaa005 [DOI] [PubMed] [Google Scholar]
  • 41. Gruzdys V, Merrigan SD, Johnson‐Davis KL. Feasibility of immunosuppressant drug monitoring by a microsampling device. J Appl Lab Med. 2019;4(2):241‐246. doi: 10.1373/jalm.2018.028126 [DOI] [PubMed] [Google Scholar]
  • 42. Vethe NT, Gustavsen MT, Midtvedt K, et al. Tacrolimus can be reliably measured with volumetric absorptive capillary microsampling throughout the dose interval in renal transplant recipients. Ther Drug Monit. 2019;41(5):607‐614. doi: 10.1097/FTD.0000000000000655 [DOI] [PubMed] [Google Scholar]
  • 43. Koster RA, Niemeijer P, Veenhof H, Hateren KV, Alffenaar JC, Touw DJ. A volumetric absorptive microsampling LC‐MS/MS method for five immunosuppressants and their hematocrit effects. Bioanalysis. 2019;11(6):495‐508. doi: 10.4155/bio-2018-0312 [DOI] [PubMed] [Google Scholar]
  • 44. Verheijen RB, Thijssen B, Atrafi F, et al. Validation and clinical application of an LC‐MS/MS method for the quantification of everolimus using volumetric absorptive microsampling. J Chromatogr B Analyt Technol Biomed Life Sci. 2019;1104:234‐239. doi: 10.1016/j.jchromb.2018.11.030 [DOI] [PubMed] [Google Scholar]
  • 45. Kita K, Mano Y. Application of volumetric absorptive microsampling device for quantification of tacrolimus in human blood as a model drug of high blood cell partition. J Pharm Biomed Anal. 2017;143:168‐175. doi: 10.1016/j.jpba.2017.05.050 [DOI] [PubMed] [Google Scholar]
  • 46. Veenhof H, Koster RA, Junier LAT, Berger SP, Bakker SJL, Touw DJ. Volumetric absorptive microsampling and dried blood spot microsampling vs. conventional venous sampling for tacrolimus trough concentration monitoring. Clin Chem Lab Med. 2020;58(10):1687‐1695. doi: 10.1515/cclm-2019-1260 [DOI] [PubMed] [Google Scholar]
  • 47. Paniagua‐González L, Lendoiro E, Otero‐Antón E, López‐Rivadulla M, de‐Castro‐Ríos A, Cruz A. Comparison of conventional dried blood spots and volumetric absorptive microsampling for tacrolimus and mycophenolic acid determination. J Pharm Biomed Anal. 2022;208:114443. doi: 10.1016/j.jpba.2021.114443 [DOI] [PubMed] [Google Scholar]
  • 48. Mathew BS, Mathew SK, Aruldhas BW, et al. Analytical and clinical validation of Dried blood spot and Volumetric Absorptive Microsampling for measurement of tacrolimus and creatinine after renal transplantation. Clin Biochem. 2022;1‐10. in press. doi: 10.1016/j.clinbiochem.2022.04.014 [DOI] [PubMed] [Google Scholar]
  • 49. Bergan S, Brunet M, Hesselink DA, et al. Personalized therapy for mycophenolate: consensus report by the International Association of Therapeutic Drug Monitoring and Clinical Toxicology. Ther Drug Monit. 2021;43(2):150‐200. doi: 10.1097/FTD.0000000000000871 [DOI] [PubMed] [Google Scholar]
  • 50. Porrini E, Ruggenenti P, Luis‐Lima S, et al. Estimated GFR: time for a critical appraisal. Nat Rev Nephrol. 2019;15(3):177‐190. doi: 10.1038/s41581-018-0080-9 [DOI] [PubMed] [Google Scholar]
  • 51. Delanaye P, Melsom T, Ebert N, et al. Iohexol plasma clearance for measuring glomerular filtration rate in clinical practice and research: a review. Part 2: Why to measure glomerular filtration rate with iohexol? Clin Kidney J. 2016;9(5):700‐704. doi: 10.1093/ckj/sfw071 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 52. Lentine KL, Kasiske BL, Levey AS, et al. KDIGO clinical practice guideline on the evaluation and care of living kidney donors. Transplantation. 2017;101(8S(1)):S1‐s109. doi: 10.1097/TP.0000000000001769 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 53. Soveri I, Berg UB, Björk J, et al. Measuring GFR: a systematic review. Am J Kidney Dis. 2014;64(3):411‐424. doi: 10.1053/j.ajkd.2014.04.010 [DOI] [PubMed] [Google Scholar]
  • 54. Krutzen E, Back SE, Nilsson‐Ehle P. Determination of glomerular filtration rate using iohexol clearance and capillary sampling. Scand J Clin Lab Invest. 1990;50(3):279‐283. doi: 10.3109/00365519009091579 [DOI] [PubMed] [Google Scholar]
  • 55. Niculescu‐Duvaz I, D'mello L, Maan Z, et al. Development of an outpatient finger‐prick glomerular filtration rate procedure suitable for epidemiological studies. Kidney Int. 2006;69(7):1272‐1275. doi: 10.1038/sj.ki.5000240 [DOI] [PubMed] [Google Scholar]
  • 56. Salvador CL, Tøndel C, Mørkrid L, et al. Glomerular filtration rate measured by iohexol clearance: A comparison of venous samples and capillary blood spots. Scand J Clin Lab Invest. 2015;75(8):710‐716. doi: 10.3109/00365513.2015.1091091 [DOI] [PubMed] [Google Scholar]
  • 57. Ion V, Legoff C, Cavalier E, et al. Determination of iohexol by capillary blood microsampling and UHPLC‐MS/MS. J Pharm Anal. 2019;9(4):259‐265. doi: 10.1016/j.jpha.2019.06.003 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 58. Dhondt L, Croubels S, de Cock P, et al. Volumetric absorptive microsampling as alternative sampling technique for renal function assessment in the paediatric population using iohexol. J Chromatogr B Analyt Technol Biomed Life Sci. 2021;1171:122623. doi: 10.1016/j.jchromb.2021.122623 [DOI] [PubMed] [Google Scholar]
  • 59. Zwart TC, Guchelaar HJ, van der Boog PJM, et al. Model‐informed precision dosing to optimise immunosuppressive therapy in renal transplantation. Drug Discov Today. 2021;26(11):2527‐2546. doi: 10.1016/j.drudis.2021.06.001 [DOI] [PubMed] [Google Scholar]
  • 60. Zwart TC, de Vries APJ, Engbers AGJ, et al. Model‐based estimation of iohexol plasma clearance for pragmatic renal function determination in the renal transplantation setting. Clin Pharmacokinet. 2021;60(9):1201‐1215. doi: 10.1007/s40262-021-00998-z [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 61. European Medicines Agency . Guideline on bioanalytical method validation 2011. [updated 3 June 2015]. Accessed: 4 August 2021. Available from: https://www.ema.europa.eu/en/documents/scientific-guideline/guideline-bioanalytical-method-validation_en.pdf
  • 62. Vicente FB, Vespa G, Miller A, Haymond S. Quantification of iohexol in serum by high‐performance liquid chromatography‐tandem mass spectrometry (LC‐MS/MS). Methods Mol Biol. 2016;1383:185‐193. doi: 10.1007/978-1-4939-3252-8_20 [DOI] [PubMed] [Google Scholar]
  • 63. Schmit DJ, Carroll LJ, Eckfeldt JH, Seegmiller JC. Verification of separate measurement procedures where analytical determinations influence the clinical interpretation of GFR: Iohexol quantitation by HPLC and LC‐MS/MS. Clin Biochem. 2019;67:16‐23. doi: 10.1016/j.clinbiochem.2019.03.007 [DOI] [PubMed] [Google Scholar]
  • 64. Zhao Y, Liu G, Angeles A, et al. A validated LC‐MS/MS method for the quantitative measurement of creatinine as an endogenous biomarker in human plasma. Bioanalysis. 2016;8(19):1997‐2005. doi: 10.4155/bio-2016-0086 [DOI] [PubMed] [Google Scholar]
  • 65. Ou M, Song Y, Li S, et al. LC‐MS/MS method for serum creatinine: comparison with enzymatic method and Jaffe method. PLoS ONE. 2015;10(7):e0133912. doi: 10.1371/journal.pone.0133912 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 66. Leuthold LA, Heudi O, Déglon J, et al. New microfluidic‐based sampling procedure for overcoming the hematocrit problem associated with dried blood spot analysis. Anal Chem. 2015;87(4):2068‐2071. doi: 10.1021/ac503931g [DOI] [PubMed] [Google Scholar]
  • 67. Denniff P, Spooner N. Volumetric absorptive microsampling: a dried sample collection technique for quantitative bioanalysis. Anal Chem. 2014;86(16):8489‐8495. doi: 10.1021/ac5022562 [DOI] [PubMed] [Google Scholar]
  • 68. Moes DJ, van der Bent SA, Swen JJ, et al. Population pharmacokinetics and pharmacogenetics of once daily tacrolimus formulation in stable liver transplant recipients. Eur J Clin Pharmacol. 2016;72(2):163‐174. doi: 10.1007/s00228-015-1963-3 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 69. Brooke J. SUS: A “quick and dirty” usability scale. In: Jordan PW, Thomas B, Weerdmeester BA, McClelland AL, eds. Usability Evaluation in Industry. London: Taylor and Francis; 1996. [Google Scholar]
  • 70. Levey AS, Stevens LA, Schmid CH, et al. A new equation to estimate glomerular filtration rate. Ann Intern Med. 2009;150(9):604‐612. doi: 10.7326/0003-4819-150-9-200905050-00006 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 71. Krutzén E, Bäck SE, Nilsson‐Ehle P. Determination of glomerular filtration rate using iohexol clearance and capillary sampling. Scand J Clin Lab Invest. 1990;50(3):279‐283. doi: 10.3109/00365519009091579 [DOI] [PubMed] [Google Scholar]
  • 72. Langman LJ, LeGatt DF, Yatscoff RW. Blood distribution of mycophenolic acid. Ther Drug Monit. 1994;16(6):602‐607. doi: 10.1097/00007691-199412000-00012 [DOI] [PubMed] [Google Scholar]
  • 73. Jusko WJ, Piekoszewski W, Klintmalm GB, et al. Pharmacokinetics of tacrolimus in liver transplant patients. Clin Pharmacol Ther. 1995;57(3):281‐290. doi: 10.1016/0009-9236(95)90153-1 [DOI] [PubMed] [Google Scholar]
  • 74. Yatscoff R, LeGatt D, Keenan R, Chackowsky P. Blood distribution of rapamycin. Transplantation. 1993;56(5):1202‐1206. doi: 10.1097/00007890-199311000-00029 [DOI] [PubMed] [Google Scholar]
  • 75. Lemaire M, Tillement JP. Role of lipoproteins and erythrocytes in the in vitro binding and distribution of cyclosporin A in the blood. J Pharm Pharmacol. 1982;34(11):715‐718. doi: 10.1111/j.2042-7158.1982.tb06206.x [DOI] [PubMed] [Google Scholar]
  • 76. Kovarik JM, Kahan BD, Kaplan B, et al. Longitudinal assessment of everolimus in de novo renal transplant recipients over the first post‐transplant year: pharmacokinetics, exposure‐response relationships, and influence on cyclosporine. Clin Pharmacol Ther. 2001;69(1):48‐56. doi: 10.1067/mcp.2001.112969 [DOI] [PubMed] [Google Scholar]
  • 77. Dresser TP, Nolph KD, Vitale FC. Transerythrocytic concentrations of urea and creatinine in normals and in azotemic patients. Int Urol Nephrol. 1977;9(2):169‐176. doi: 10.1007/BF02082020 [DOI] [PubMed] [Google Scholar]
  • 78. Passing H, Bablok. A new biometrical procedure for testing the equality of measurements from two different analytical methods. Application of linear regression procedures for method comparison studies in clinical chemistry, Part I. J Clin Chem Clin Biochem. 1983;21(11):709‐720. [DOI] [PubMed] [Google Scholar]
  • 79. Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1(8476):307‐310. [PubMed] [Google Scholar]
  • 80. Capiau S, Veenhof H, Koster RA, et al. Official International Association for Therapeutic Drug Monitoring and Clinical Toxicology guideline: development and validation of dried blood spot‐based methods for therapeutic drug monitoring. Ther Drug Monit. 2019;41(4):409‐430. doi: 10.1097/FTD.0000000000000643 [DOI] [PubMed] [Google Scholar]
  • 81. Wilcoxon F. Individual comparisons by ranking methods. Biometrics. 1945;1(6):80‐83. doi: 10.2307/3001968 [DOI] [Google Scholar]
  • 82. Moes DJ, Press RR, den Hartigh J, van der Straaten T, de Fijter JW, Guchelaar HJ. Population pharmacokinetics and pharmacogenetics of everolimus in renal transplant patients. Clin Pharmacokinet. 2012;51(7):467‐480. doi: 10.2165/11599710-000000000-00000 [DOI] [PubMed] [Google Scholar]
  • 83. Woillard JB, de Winter BC, Kamar N, Marquet P, Rostaing L, Rousseau A. Population pharmacokinetic model and Bayesian estimator for two tacrolimus formulations‐‐twice daily Prograf and once daily Advagraf. Br J Clin Pharmacol. 2011;71(3):391‐402. doi: 10.1111/j.1365-2125.2010.03837.x [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 84. Staatz CE, Tett SE. Maximum a posteriori Bayesian estimation of mycophenolic Acid area under the concentration‐time curve: is this clinically useful for dosage prediction yet? Clin Pharmacokinet. 2011;50(12):759‐772. doi: 10.2165/11596380-000000000-00000 [DOI] [PubMed] [Google Scholar]
  • 85. Langers P, Press RR, Inderson A, et al. Limited sampling model for advanced mycophenolic acid therapeutic drug monitoring after liver transplantation. Ther Drug Monit. 2014;36(2):141‐147. doi: 10.1097/FTD.0b013e3182a37a1e [DOI] [PubMed] [Google Scholar]
  • 86. Proost JH, Meijer DK. MW/Pharm, an integrated software package for drug dosage regimen calculation and therapeutic drug monitoring. Comput Biol Med. 1992;22(3):155‐163. doi: 10.1016/0010-4825(92)90011-B [DOI] [PubMed] [Google Scholar]
  • 87. Harding SD, Armstrong JF, Faccenda E, et al. The IUPHAR/BPS guide to PHARMACOLOGY in 2022: curating pharmacology for COVID‐19, malaria and antibacterials. Nucleic Acids Res. 2022;50(D1):D1282‐D1294. doi: 10.1093/nar/gkab1010 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 88. Fraser CG. Making better use of differences in serial laboratory results. Ann Clin Biochem. 2012;49(1):1‐3. doi: 10.1258/acb.2011.011203 [DOI] [PubMed] [Google Scholar]
  • 89. Mafham MM, Niculescu‐Duvaz I, Barron J, et al. A practical method of measuring glomerular filtration rate by iohexol clearance using dried capillary blood spots. Nephron Clin Pract. 2007;106(3):c104‐c112. doi: 10.1159/000102997 [DOI] [PubMed] [Google Scholar]
  • 90. Luis‐Lima S, Gaspari F, Negrin‐Mena N, et al. Iohexol plasma clearance simplified by dried blood spot testing. Nephrol Dial Transplant. 2018;33(9):1597‐1603. [DOI] [PubMed] [Google Scholar]
  • 91. Delahaye L, Heughebaert L, Lühr C, Lambrecht S, Stove CP. Near‐infrared‐based hematocrit prediction of dried blood spots: An in‐depth evaluation. Clin Chim Acta. 2021;523:239‐246. doi: 10.1016/j.cca.2021.10.002 [DOI] [PubMed] [Google Scholar]
  • 92. van de Velde D, van der Graaf JL, Boussaidi M, et al. Development and validation of hematocrit level measurement in dried blood spots using near‐infrared spectroscopy. Ther Drug Monit. 2021;43(3):351‐357. doi: 10.1097/FTD.0000000000000834 [DOI] [PubMed] [Google Scholar]
  • 93. Zwart TC, Moes D, van der Boog PJM, et al. Model‐informed precision dosing of everolimus: external validation in adult renal transplant recipients. Clin Pharmacokinet. 2021;60(2):191‐203. doi: 10.1007/s40262-020-00925-8 [DOI] [PMC free article] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

TABLE S1 Summary of the within‐run and between‐run accuracy and precision for all analytes.

TABLE S2 Summary of method agreement between the DBS, VAMS and reference methods, as evaluated during analytical cross‐validation.

TABLE S3 Estimated dried blood spot (DBS) and volumetric absorptive microsample (VAMS) to venous EDTA whole blood or plasma ratios over the haematocrit range, relative to their estimated ratios at the population mean haematocrit.

FIGURE S1 Observed dried blood spot (DBS) and volumetric absorptive microsample (VAMS) to venous EDTA whole blood or venous EDTA plasma ratios over the haematocrit (HCT) range. The solid blue and gold lines depict the linear regression line and the grey‐shaded areas its standard error. The linear regression equation is depicted for each analyte and matrix.

FIGURE S2 Daily dosing recommendations for (A) tacrolimus and (B) mycophenolic acid (MPA), based on the dried blood spot (DBS) and volumetric absorptive microsample (VAMS) area under the concentration–time curve (AUCs) as compared to those based on the corresponding reference AUCs. The dots are sized and coloured according to the number of patients (N) with a given daily dosing recommendation.

FIGURE S3 Passing–Bablok regression plots of the uncorrected mycophenolic acid (MPA; A, B), uncorrected iohexol (C, D), and exploratory everolimus (E, F) results. The solid blue and gold lines represent the Passing–Bablok regression fits for the dried blood spot (DBS) and volumetric absorptive microsampling (VAMS) methods, respectively.

FIGURE S4 Bland–Altman plots for the uncorrected mycophenolic acid (MPA; A, B), uncorrected iohexol (C, D) and exploratory everolimus results. Solid and dotted blue and gold lines represent the mean bias and the lower and upper limits of agreement (LoA) for the dried blood spot (DBS) and volumetric absorptive microsampling (VAMS) techniques, respectively. The grey‐shaded area depicts the ±20% ratio difference limit around the line of identity, with any observations exceeding the ±20% ratio difference limit highlighted in red.

FIGURE S5 Evaluation of the performance of the 3 conversion methods for translating iohexol concentrations in capillary whole blood to plasma concentrations, with the applied method highlighted in dark grey. Solid and dotted black lines represent the mean bias and the lower and upper limits of agreement (LoA). The grey‐shaded area depicts the ±20% ratio difference limit around the line of identity, with any observations exceeding the ±20% ratio difference limit highlighted in red. The dotted blue line and blue shaded area depict the linear regression line and its standard error.

Data Availability Statement

The datasets generated during and/or analysed during this study are available from the corresponding author upon reasonable request.


Articles from British Journal of Clinical Pharmacology are provided here courtesy of Wiley

RESOURCES