(Mis)perception and Use of Unsterile Water in Home Medical Devices, PN View 360+ Survey, United States, August 20211

Shanna Miko 1,2,3,, Sarah A Collier 1,2,3, Claire E Burns-Lynch 1,2,3, Ashley A Andújar 1,2,3, Katharine M Benedict 1,2,3, Julia C Haston 1,2,3, Catherine O Hough 1,2,3, Jennifer R Cope 1,2,3
PMCID: PMC9881759  PMID: 36692441

Abstract

Tap water is not sterile, and its use in home medical devices can result in infections from waterborne pathogens. However, many participants in a recent survey in the United States said tap water could safely be used for home medical devices. These results can inform communication materials to reduce the high consequence of infections.

Keywords: (Mis)perception, aerosolized tap water, contact lenses, tap water exposure, bacteria, nasal rinsing, unsterile water, sterile water, waterborne disease, enteric infections, home medical devices, biofilm, PN View 360+ Survey, United States


Tap water in the United States is treated to meet safe drinking standards; however, low levels of microorganisms remain in drinking water distribution systems, wells, and premise plumbing (1,2). Although most of these microorganisms are harmless and the water is safe for drinking and cooking, it might not always be safe for other uses, such as aerosolized inhalation and ocular or nasal irrigation (24). Microorganisms that can be found in water systems include Pseudomonas aeruginosa, nontuberculous mycobacteria (NTM), Legionella spp., Acanthamoeba spp., and Naegleria fowleri (1,2). In the United States, biofilm-associated pathogens such as Pseudomonas spp., NTM, and Legionella spp. are responsible for a large portion of the 120,000 hospitalizations, 7,000 deaths, and billions in direct healthcare costs annually related to waterborne diseases (5).

Persons who are at a higher risk for acquiring high-consequence opportunistic infections include the elderly, infants and young children, and persons who have weakened immune systems and other concurrent conditions (2,6). Some persons who have weakened immune systems might want to take precautions and use water free from microbes. Sterile water does not contain organic microbes but might contain inorganic materials, such as minerals; distilled water does not contain organic and inorganic materials (7).

At home, water is used for various health activities, including filling nasal rinsing devices and respiratory devices such as continuous positive airway pressure (CPAP) machines, vaporizers, and portable humidifiers. We hypothesize that people might not understand that tap water is not sterile, leading to its use for specific purposes, such as nasal rinsing, inhalation, and contact lens rinsing that are not recommended.

One study reported demographic data on household water use for home medical devices (8). Few data sources describe the understanding of sterile water sources by the population of the United States. This study aimed to quantify perceptions of sterile water, water sources, and actual use of water for home medical purposes among US adults and identify differences among demographic groups regarding perceptions and use of water. These findings can help focus educational efforts to increase awareness of safe water use practices for home medical activities, supporting healthcare providers and public health practitioners in advising their patients and communities about safe water practices for home medical activities.

The Study

For this cross-sectional study, we used data from Porter Novelli Public Services and the ENGINE Insights’ PN View 360+ survey (https://styles.porternovelli.com), delivered August 16–18, 2021 (Appendix). Porter Novelli used quota sampling and statistical weighting to make the panel representative of the US population by sex, age, region, race/ethnicity, and education. All analyses were performed using SAS software version 9.4 (SAS Institute Inc., https://www.sas.com), and p<0.05 indicated significance. Survey procedures were used to assess the proportions of response variables by demographics. χ2 tests were conducted to test the association of each response variable with each demographic variable. Post hoc Wald F tests from contrast statements and the SurveyReg procedure SAS were used to compare subgroups for demographic variables with >2 levels.

The survey defined tap water as water from faucets and asked participants if they agreed or disagreed with a series of statements (Table 1). One-third (33%, 95% CI 30%‒36%) of respondents incorrectly answered that tap water does not have bacteria or living things present. Men, African American or Black persons, and urban residents were more likely to answer incorrectly. More than half (62%, 95% CI 59%‒66%) of participants said that tap water could be used for rinsing sinuses, 50% (95% CI 47%‒54%) for rinsing contact lenses, and 42% (95% CI 38%‒45%) for respiratory devices. Men and urban residents were more likely to choose >1 of these incorrect answers.

Table 1. Demographic characteristics of 1,004 respondents to question about potential uses for tap water, by response, in survey of knowledge about uses for tap water, PN 360 View 2021, United States*.

Characteristic Do you agree or disagree with the following statements about US tap water?
Can be used for drinking Can be used for rinsing contact lenses Can be used for nasal rinsing Can be used in respiratory devices† Bacteria and other living things are not present in US tap water
I don’t know
38
140
157
194
119
General population
81 (78‒83)
50 (47‒54)
62 (59‒66)
42 (38‒45)
33 (30‒36)
Sex
F 77 (73‒81) 43 (38‒48) 58 (52‒63) 37 (32‒42 24 (20‒28)
M 84 (81‒88) 57 (52‒62) 67 (62,72) 46 (41‒51) 42 (37‒47)
p value
0.0090
0.0002
0.0073
0.0153
<0.0001
Race
Black or African American 76 (68‒84) 47 (37‒57) 58 (48,68) 48 (37‒58) 48 (38‒58)
Other‡ 69 (59‒78) 46 (35‒57) 57 (46,68) 35 (24‒45) 26 (17‒35)
p value
0.0013
0.5781
0.2917
0.2145
0.0039
Ethnicity
Hispanic§ 67 (58‒76) 48 (38‒58) 60 (51,70) 38 (28‒48) 31 (22‒40)
Non-Hispanic 83 (81‒86) 50 (47‒54) 63 (59,66) 42 (38‒46) 33 (30‒37)
p value <0.0001 0.7034 0.6528 0.4189 0.6011
Age, y
18–34 73 (68‒79) 50 (44‒56) 65 (59,71) 45 (38‒52) 38 (31‒44)
35–54 80 (75‒85) 52 (46‒58) 58 (52,64) 37 (31‒43) 35 (29‒40)
>55 86 (82‒90) 49 (43‒55) 64 (58,70) 43 (36‒49) 28 (23‒33)
p value
0.0008
0.7743
0.2784
0.1910
0.0378
Region
Northeast 80 (74‒87) 59 (51‒67) 66 (57,74) 49 (41‒58) 34 (26‒41)
Midwest 85 (80‒90) 46 (38‒54) 60 (53,68) 41 (33‒49) 33 (26‒41)
South 82 (78‒86) 48 (42‒54) 63 (58,69) 40 (34‒45 34 (29‒39)
West 75 (68‒81) 51 (44‒58) 61 (54,68) 39 (32‒47) 30 (24‒37)
p value
0.0663
0.1199
0.7756
0.2810
0.8283
Metro status
Urban 81 (76‒86) 59 (52‒65) 66 (60,72) 49 (43‒56) 44 (38‒50)
Suburban 79 (75‒83) 46 (40‒51) 59 (54,64) 38 (32‒43) 28 (24‒33)
Rural 83 (78‒88) 47 (40‒55) 64 (57,72) 39 (31‒46) 28 (21‒34)
p value
0.5218
0.0052
0.1933
0.0163
<0.001
Household income
<$59,999 79 (76‒83) 48 (43‒53) 62 (57,66) 39 (35‒44) 31 (26‒35)
>$60,000 82 (78‒86) 53 (47‒58) 63 (58,68) 44 (39‒50) 36 (31‒41)
p value
0.2638
0.2013
0.6294
0.1722
0.0978
Water source¶
Private well 90 (85‒96) 63 (54‒72) 71 (63‒79) 55 (46‒65) 48 (39‒57)
Municipal 81 (78‒84) 48 (44‒52) 61 (57‒65) 39 (35‒43) 30 (26‒34)
p value 0.0101 0.0046 0.0540 0.0009 0.0002

*Values are percentages agreeing (95% CIs) unless otherwise indicated. Boldface indicates significance (p<0.05 by χ2 or by Wald F-tests where there are >3 categories). “I don’t know” was not included in analysis; “Agree” and “Strongly Agree” were analyzed as “Agree”; “Disagree” and “Strongly Disagree” were not included in analysis. PN, Porter Novelli Public Services and the ENGINE Insights’ PN View 360+ Survey. †Respiratory devices include vaporizers, humidifiers, and continuous positive airway pressure machines. ‡Other race grouped persons who identified as >1 race, Asian, Native American, Alaska Native, or other because of small sample size. §Hispanic, Spanish, or Latino. ¶n = 932.

Respondents were asked how they used their household tap water (Table 2). Most persons reported using tap water for drinking, cooking, bathing, and handwashing. Approximately one quarter (24%, 95% CI 21%‒27%) of persons reported filling humidifiers or CPAP machines with tap water, 13% (95% CI 11%‒15%) reported using tap water for nasal rinsing, and 9% (95% CI 7%‒11%) reported using tap water for rinsing contact lenses.

Table 2. Demographic characteristics of 1,004 respondents to question about how they use tap water, by response, in survey of knowledge about tap water, PN 360 View 2021, United States*.

Characteristic How do you use your household tap water?
Consumption† Bathing/ showering Washing hands Rinsing contact lenses Nasal rinsing Filling respiratory devices‡
General population
66 (63‒69)
84 (82‒86.4)
88 (86‒90)
9 (7‒11)
13 (11‒15)
24 (21‒27)
Sex
F 64 (59‒68) 83 (80‒87) 87 (84‒90) 8 (5‒10) 12 (9‒15) 24 (21‒28)
M 68 (63‒72) 85 (81‒88) 89 (86‒92) 10 (7‒13) 14 (11‒17) 23 (20‒27)
p value
0.2140
0.6004
0.3666
0.3034
0.3902
0.7322
Race
White 71 (68‒74) 87 (84‒89) 89 (87‒92) 9 (7‒11) 13 (11‒16) 24 (21‒27)
Black or African American 53 (44‒62) 77 (70‒85) 85 (78‒91) 10 (5‒16) 10 (5‒,15) 22 (15‒30)
Other§ 52 (42‒62) 77 (69‒86) 83 (75‒91) 8 (3‒14) 14 (7‒20) 24 (15‒32)
p value
<0.0001
0.0078
0.0814
0.8320
0.5920
0.9130
Ethnicity
Hispanic# 51 (42‒61) 71 (63‒79) 78 (70‒86) 13 (7‒19) 21 (14‒29) 25 (17‒33)
Non-Hispanic 69 (65‒72) 87 (84‒89) 90 (88‒92) 8 (6‒10) 11 (9‒13) 24 (21‒27)
p value
0.0003
<0.0001
0.0003
0.0813
0.0012
0.7937
Age, y
18–34 57 (51‒63) 73 (67‒78) 81 (76‒86) 14 (10‒18) 19 (14‒24) 25 (20‒30)
35–54 64 (58‒69) 83 (79‒88) 87 (83‒91) 10 (7‒14) 13 (10‒17) 25 (20‒30)
>55 74 (70‒79) 93 (90‒96) 94 (9‒97) 4 (2‒5) 8 (5‒11) 22 (18‒26)
p value
<0.0001**
<0.0001††
<0.0001**
<0.0001**
0.0002**
0.5591
Region
Northeast 70 (63‒77) 82 (76‒88) 89 (84‒94) 10 (5‒14) 12 (7‒16) 31 (24‒38)
Midwest 69 (63‒76) 84 (78‒89) 85 (80‒91) 8 (4‒12) 12 (8‒17) 27 (21‒34)
South 66 (61‒71) 87 (84‒91) 89 (86‒93) 8 (5‒11) 12 (8‒15) 18 (14‒22)
West 58 (52‒65) 81 (75‒86) 87 (82‒91) 10 (6‒15) 15 (11‒20) 25 (19‒31)
p value
0.0601
0.2120
0.5344
0.7265
0.5647
0.0054‡‡
Community setting
Urban 62 (56‒67) 82 (78‒87) 88 (84‒2) 13 (9‒17) 16 (12‒20) 24 (19‒28)
Suburban 65 (60‒69) 83 (79‒87) 86 (83‒90) 8 (5‒10) 13 (10‒16) 24 (20‒28)
Rural 74 (68‒80) 89 (85‒93) 91 (86‒95) 6 (3‒9) 7 (4‒11) 24 (18‒30)
p value
0.0189§§
0.1004
0.3463
0.0115¶¶
0.0147§§
0.9797
Household income
<$59,999 63 (59‒67) 83 (80‒87) 86 (83‒89) 7 (5‒10) 9 (7‒12) 20 (17‒24)
>$60,000 69 (65‒74) 85 (82‒89) 90 (87‒93) 11 (8‒14) 17 (14‒21) 29 (25‒34)
p value
0.0608
0.4593
0.0837
0.0355
0.0003
0.0024
Water source, n = 932
Private well 68 (61‒76) 76 (69‒83) 82 (75‒88) 14 (8‒19) 18 (12‒24) 38 (29‒46)
Municipal 67 (63‒70) 87 (84‒89) 90 (87‒92) 8 (6‒10) 12 (10‒14) 22 (19‒25)
p value 0.6712 0.0016 0.0102 0.0179 0.0388 0.0001

*Values are percentages (95% CIs) unless otherwise indicated. Boldface indicates significance (p<0.05 by χ2 or by Wald F-tests where there are >3 categories; specific comparisons are footnoted). PN360 View, Porter Novelli Public Services and the ENGINE Insights’ PN View 360+ Survey. †Includes drinking, rinsing produce, or making ice. ‡Respiratory devices include vaporizers, humidifiers, and continuous positive airway pressure machines. §Other race grouped persons who identified as >1 race, Asian, Native American, or Alaska Native, or other because of small sample size. ¶For comparison between White and Black or African American and between White and other race categories. #Hispanic, Spanish, or Latino. **For comparisons between 18–34-y and >55-y age groups and between 35–54-y and >55-y age groups. ††For comparisons between 18–34-y and 35–54-y age groups, between 18–34-y and >55-y age groups, and between 35–54-y and >55-y age groups. ‡‡For comparisons between Northeast and South, between Midwest and South, and between South and West. §§For comparisons between urban and rural and between suburban and rural. ¶¶For comparisons between urban and suburban and between urban and rural.

Conclusions

The results of this survey highlight opportunities to reinforce messaging regarding appropriate uses of tap water and recommendations for using water in medical devices at home. Although most persons understand what sterile water is and acknowledge that tap water is not sterile, a large proportion of persons responded that tap water can be used for nasal rinsing devices, contact lens rinsing, and filling respiratory devices. These findings represent an opportunity for public health practitioners and water utilities to continue communicating the value of US tap water and its appropriate use.

Although waterborne opportunistic infections can occur through multiple routes and can depend on a person’s health status, most NTM and Legionella infections are acquired through inhalation (9). In this study, 24% of respondents reported filling respiratory devices with tap water, consistent with a recent study in which 20% of respondents reported filling respiratory devices with tap water (8). Studies have demonstrated measurable concentrations of NTM (9), concentrated minerals (10), and other contaminants in aerosols from humidifiers (11). Water quality affects the quality of aerosolized air emitted from humidifiers, CPAP machines, and vaporizers, underlying the need for sterilized or distilled water to be used in those devices. Healthcare providers and pharmacists are uniquely positioned to share additional recommendations on appropriate waters (i.e., sterile, distilled, or boiled and cooled) for respiratory devices when they are sold or prescribed. Persons should be informed that they can reduce their exposure to waterborne pathogens by using distilled water or water that has been appropriately boiled and cooled and by regularly cleaning and disinfecting all respiratory devices that use water.

Water can be sterilized at home for safe home medical use for respiratory devices and neti pots (containers designed to rinse debris or mucus from the nasal cavity). Ordemann et al. tested water treatment options of UV light treatment, granular activated carbon filtration, and boiling to eliminate Staphylococcus aureus, Pseudomonas aeruginosa, Moraxella catarrhalis, Acinetobacter baumannii, Klebsiella pneumoniae, Legionella pneumophila, and N. fowleri. They reported that sterilization could be achieved by boiling water for 5 minutes then cooling, or by UV treatment (e.g., SteriPEN, https://www.katadyngroup.com) for 45 seconds or following the manufacturer’s instructions (12). The Centers for Disease Control and Prevention also has recommendations for preparing safer water for nasal rinsing, which includes boiling for 1 minute (3 minutes at elevations >6,500 feet) and cooling (13). Focused public health messaging and communications from health departments, pharmacists, and healthcare providers should increase awareness of how best to achieve sterile water at home for those who need it, reducing the number of biofilm-associated waterborne pathogens persons are exposed to when performing home medical activities.

Biofilm-associated waterborne pathogens make up a substantial portion of waterborne disease-related illnesses and deaths in the United States. Our results indicate demographic groups to which future public health and provider efforts should be directed to promote appropriate household tap water management practices when using home medical devices that aerosolize water or irrigate the eyes and nose. Public health messaging and healthcare provider guidance that incorporates risk factors for these device users and aligns with recommendations of the Centers for Disease Control and Prevention (2) are effective risk communication strategies that can influence population behavior change.

Appendix

Additional information on (mis)perception and use of unsterile water in home medical devices, PN View 360+ Survey, United States, August 2021.

22-1205-Techapp-s1.pdf (199.9KB, pdf)

Acknowledgments

We thank Fred Fridinger, Deanne Weber, and Amanda Garcia-Williams for providing assistance.

Biography

Dr. Miko is a nurse and Epidemic Intelligence Service Officer in the Department of Food, Water, and Environmental Diseases, National Center for Emerging and Zoonotic Infectious Diseases, Centers for Disease Control and Prevention, Atlanta, GA. Her primary research interest is improving public health nationally and internationally through preventing and controlling disease, disability, and death caused by waterborne and environmental incidents and building capacity for better health outcomes.

Footnotes

Suggested citation for this article: Miko S, Collier SA, Burns-Lynch CE, Andújar AA, Benedict KM, Haston JC, et al. (Mis)perception and use of unsterile water in home medical devices, PN View 360+ Survey, United States, August 2021. Emerg Infect Dis. 2022 Feb [date cited]. https://doi.org/10.3201/eid2902.221205

1

Preliminary results from this study were presented at the 2022 Epidemic Intelligence Service (EIS) Conference, May 2‒5, 2022, Atlanta, Georgia, USA.

References

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

Appendix

Additional information on (mis)perception and use of unsterile water in home medical devices, PN View 360+ Survey, United States, August 2021.

22-1205-Techapp-s1.pdf (199.9KB, pdf)

Articles from Emerging Infectious Diseases are provided here courtesy of Centers for Disease Control and Prevention

RESOURCES