Skip to main content
Springer logoLink to Springer
. 2023 Feb 3;59(2):15. doi: 10.1140/epja/s10050-023-00930-y

Muonic atom spectroscopy with microgram target material

A Adamczak 1, A Antognini 2,3, N Berger 4,5, T E Cocolios 6, N Deokar 4,5, Ch E Düllmann 5,7,8,9, A Eggenberger 3, R Eichler 2, M Heines 6, H Hess 10, P Indelicato 11, K Kirch 2,3, A Knecht 2,, J J Krauth 5,12, J Nuber 2,3, A Ouf 12, A Papa 2,13, R Pohl 5,12, E Rapisarda 2, P Reiter 10, N Ritjoho 2,3, S Roccia 14, M Seidlitz 10, N Severijns 6, K von Schoeler 3, A Skawran 2,3, S M Vogiatzi 2,3, N Warr 10, F Wauters 4,5
PMCID: PMC9898421  PMID: 36751673

Abstract

Muonic atom spectroscopy–the measurement of the x rays emitted during the formation process of a muonic atom–has a long standing history in probing the shape and size of nuclei. In fact, almost all stable elements have been subject to muonic atom spectroscopy measurements and the absolute charge radii extracted from these measurements typically offer the highest accuracy available. However, so far only targets of at least a few hundred milligram could be used as it required to stop a muon beam directly in the target to form the muonic atom. We have developed a new method relying on repeated transfer reactions taking place inside a 100 bar hydrogen gas cell with an admixture of 0.25% deuterium that allows us to drastically reduce the amount of target material needed while still offering an adequate efficiency. Detailed simulations of the transfer reactions match the measured data, suggesting good understanding of the processes taking place inside the gas mixture. As a proof of principle we demonstrate the method with a measurement of the 2p-1s muonic x rays from a 5 μg gold target.

Introduction

Muonic atoms are a type of exotic atoms where a negative muon (μ-) is captured by an atomic nucleus and forms a hydrogen-like system. For this capture process to take place, muons need to be decelerated to a few eV, where they are then captured in a high Rydberg state (main quantum number n 14). From this state they subsequently cascade down to the 1s state via collisions and Auger and radiative transitions, during the latter step emitting so-called muonic x rays. The details of this capture and cascade depend on the target material and density [1, 2], the entire process transpires however within at most a few nanoseconds for low-Z materials1 (much less for higher-Z elements), which is less than the time resolution of a typical x-ray detector. Once a muonic atom is formed, the muon is unlikely to transfer to another atom, with the exception of muonic hydrogen which is a neutral system and thus can easily penetrate the electron cloud of nearby atoms. In the ground state, the muon will either decay in orbit, or be captured by the atomic nucleus [3]. This process becomes dominant for Z 14 due to a strong Z4 dependence, thereby considerably reducing the lifetime of the exotic atom.

Due to the relatively large muon mass of 105.7 MeV/c2, the muonic Bohr radius is 207 times smaller compared to regular atoms leading to a large overlap between the muonic and nuclear wave function at lower n orbits. This makes muonic atoms a very sensitive system to probe the nuclear charge distribution, first and foremost the nuclear charge radius <r2> which is typically derived from the 2p-1s transition energy [4, 5]. In this way muonic atoms provide complementary information to electron scattering and laser spectroscopy data, respectively [610].

To measure the characteristic muonic x rays from a particular isotope, one needs to stop a secondary muon beam available at a proton accelerator facility such as HIPA at the Paul Scherrer Institute (PSI), MUSE at J-PARC, the muon sources at TRIUMF and RAL, and MuSIC at Osaka. These muons have a typical momentum of 10–100 MeV/c. To efficiently stop such muons, one usually needs a solid target thickness of O(1 mm) [11], which limits the available muonic x-ray data to stable isotopes from which one can produce such a macroscopic target. However, the charge radii of several long lived radioactive isotopes are of interest to benchmark isotope shift measurements from laser spectroscopy [12], or to serve as input for atomic parity violation experiments with radium [13], which was the motivation to develop the method presented in this paper. In order to perform laser spectroscopy on the lightest muonic atoms, the Lamb Shift experiment at PSI has developed a dedicated low-energy muon beamline to slow down muons to a few keV in kinetic energy  [14]. In this paper we present an alternative approach, where a standard negative muon beam is stopped in a high-pressure gaseous hydrogen target, and the negative muon is then transported to a few μg/cm2 target by means of diffusion and a series of transfer reactions. A total efficiency per incoming muon of order one percent is achieved in this way.

The main focus of the paper is the detailed description of the developed method (Sect. 2) and apparatus (Sect. 4) allowing us to perform muonic atom spectroscopy with such microgram targets. Additionally, we have developed a Monte Carlo program to simulate all relevant processes taking place in the high-pressure gas cell (Sect. 3). The paper concludes in Sect. 5 with a description of the first results that show the performance of the apparatus in comparison to simulation and a first proof-of-principle measurement with a 5 μg gold target.

Method

The method presented in this paper for performing muonic atom spectroscopy with microgram target material relies on transfer reactions taking place inside a high-pressure hydrogen gas cell operating at 100 bar, corresponding to about 10% of liquid hydrogen density, with a small admixture of deuterium. The method is inspired by the work described in Refs. [1517] and the wealth of knowledge gained in the pursuit of muon catalyzed fusion (see, e.g., Refs. [18, 19]) on the behavior and interaction of the muonic hydrogen isotopes inside gas cells. A sketch of the method can be found in Fig. 1 with the details given in the following paragraphs.

Fig. 1.

Fig. 1

Sketch of the method employed to measure muonic x rays emitted from a target with only microgram mass. The negative muon enters a 100 bar hydrogen gas cell with a small admixture of deuterium. Upon stopping, the muon forms muonic hydrogen μp and transfers to a deuteron upon collision with a deuterium molecule forming muonic deuterium μd. Due to its low scattering cross section, μd can travel over a large distance potentially reaching the microgram target at the back of the cell. Here, the muon transfers again to the target nucleus thereby emitting the characteristic muonic x rays

Once the negative muon comes to rest inside the hydrogen gas it is quickly captured by a hydrogen molecule forming the excited μ-molecular complex (ppμe) with the proton p and electron e. This complex splits apart [20] by either direct dissociation

(ppμe)(μp)+(pe) 1

or by electron emission and subsequent dissociation

(ppμe)(ppμ)+e(μp)+p+e. 2

The formed muonic hydrogen atom (μp) quickly de-excites to the ground state and is thermalized by multiple scatterings on the surrounding hydrogen molecules. Due to the high-pressure the diffusion radius of the muonic hydrogen atom is limited to only about 0.5 mm at the given conditions. The key to increasing the mobility and distance that the muons can travel lies in the small admixture of deuterium that typically amounts to 0.25% at the chosen pressure of 100 bar. Once the muonic hydrogen atom scatters with deuterium the muon is quickly transferred – due to the increased binding energy – forming muonic deuterium (μd) in the 1s ground state, where d is the deuteron:

(μp)+d(μd)+p 3

The rate of this transfer at the present conditions is 3.5×106/s [21]. Because of the increased binding energy the formed muonic deuterium atom is accelerated resulting in a kinetic energy of 45 eV [22]. This energy is quickly reduced in subsequent scatterings. However, due to the Ramsauer-Townsend effect [23] the transport scattering cross section2 of μd on H2 features a deep minimum at around 4 eV as shown in Fig. 2 [22, 24, 25]. This effect increases the range of the μd atom in the gas cell by about a factor 10 over the one of the thermalized μp atom allowing some of the muons to reach the microgram target material mounted at the back of the gas cell.

Fig. 2.

Fig. 2

Calculated total cross sections for the elastic scattering of μd on H2 and D2 and transport cross sections (indicated with σmt) for the elastic scattering of μd on H2 [25]. The gain in kinetic energy by the transfer from μp to μd is indicated by the vertical green line. The cross sections for the scattering of μd on D2 depend on the hyperfine state F of the μd atom and are included in brown

Once the μd atom reaches the target material, the tightly-bound and neutral atom easily penetrates the electron cloud and the muon quickly transfers yet again to the target nucleus Z [26, 27]:

(μd)+Z(μZ)+d 4

The transfer inside the solid target material is not well understood theoretically and has not been studied in great detail experimentally. Estimates for the transfer rate can be obtained from the calculations of Refs. [28, 29]. For gold the estimated transfer rate is 1.6×1012/s as given by the equation in the conclusions of Ref. [28]. Neglecting any scattering effects and assuming an energy of the μd atom of 4 eV, this translates to a characteristic length of 12 nm at which the fraction of remaining μd atoms has dropped in gold to 1/e.

Simulation

An efficient measurement requires as many muons as possible to reach the target nuclei after having stopped in the target gas and formed muonic hydrogen atoms. We have conducted Monte Carlo simulations of the transport process to optimize the target geometry and the gas conditions. In order to simulate the drift of μp and μd atoms through the gas volume, it is necessary to quantify the collisions between the atoms in the 1s state and the molecules of the target gas. In addition to the transfer reaction discussed in Equation (3), the following scattering processes take place:

μaF+M2μaF+M2 5

Here, a denotes a proton or deuteron bound to a negative muon and M2 denotes either one of the molecules H2, D2 or HD. During the scattering process, the hyperfine state F of the muonic atom can be changed when the μa atom undergoes a spin-flip reaction in which the atomic nucleus a is exchanged with one of the nuclei of the molecule. At collision energies of eV and more, the differential cross sections for the molecular scattering processes are approximately equivalent to those for the corresponding nuclear processes, which consider three-body Coulomb interactions between the muonic atom and the molecular nuclei and have been addressed in numerous efforts [3033]. In the experiment, however, the muonic hydrogen atoms can have kinetic energies well below 0.1 eV for a significant amount of time. In this regime, molecular binding effects, electron screening and spin correlations of specific rotational states can not be neglected any more. Furthermore, excitations and de-excitations of rotational and rotational-vibrational molecular states introduce additional inelastic components to the collisions. For this reason, molecular cross sections need to be used for a realistic simulation of the diffusion process. The method of calculating such molecular cross sections has been described in detail in [34].

The Monte Carlo simulations are based on the implementation of custom molecular scattering processes in the Geant4 framework [35] with use of the G4beamline program [36]. The implemented scattering processes work with double-differential scattering rates in the laboratory reference frame which have been obtained from the differential cross sections in the center-of-mass provided by [25]. When transferring to the lab frame, the thermal motion of the target molecules is taken into account by averaging over the Maxwell-Boltzmann distribution of the momenta of the gas molecules.

In addition to the custom molecular scattering processes, the simulations include the physics processes provided by Geant4 for the interaction of the negative muons with materials in the target region. The simulations start with muons from the beam passing through the entrance detector in front of the target cell. We assume the muons in the beam to be normally distributed around the beam center with a standard deviation of 10 mm. The momentum is distributed normally around the mean momentum with a momentum bite of 4% (full width at half maximum). Muons that enter the gas volume through the window and stop in the gas are substituted with μp atoms in the 1s state or directly with μd atoms (with low probability corresponding to the deuterium concentration). The muonic atoms undergo multiple collisions with molecules including the transfer reaction while drifting through the gas volume. Eventually, the tracks are killed when reaching the target surface or another surface inside the gas cell, corresponding to the transfer towards heavy nuclei. All simulation results presented in this text correspond to a target disk of 15 mm diameter which is placed 15 mm behind the window of the gas cell.

In reality, the formation process of muonic atoms with the subsequent fast de-excitation cascade is highly complex. Collisions of the large, excited muonic atoms with surrounding molecules influence the kinetic energy distribution of the atoms after reaching the 1s state. Based on the standard cascade model [37], different theoretical models of the cascade process have been developed [3844]. Their results for the kinetic energy of muonic atoms after the cascade, however, show strong variations. In accordance with experimental findings [45, 46], the most recent calculations [43, 44] find that a part of the atoms ends up thermalized after the cascade while other atoms cover the whole energy range up to several tens of eV, with few atoms even reaching energies of 100 to 200 eV. For the results of the transport simulations described here, no significant effect of the initial energy distribution could be observed. Due to the high density of around 10% of liquid hydrogen, the μp atoms at a kinetic energy of 100 eV have mean free paths of only a few μm, which makes them slow down after minimal distances. For the simulation results presented in this text, the initial kinetic energy of the muonic atoms in the 1s state was assumed to be distributed according to a Maxwell-Boltzmann distribution with a mean energy of 1 eV.

Time distributions of muonic hydrogen atoms reaching the target disk are presented in Fig. 3 for various deuterium concentrations in the hydrogen gas. The distributions were obtained for a muon beam with a mean momentum of 28.0 MeV/c and have been normalized to the number of entrance counts. The distribution for pure hydrogen (cD=0%) shows a prompt peak stemming from μp atoms that reach the target disk directly after formation. The other distributions show significant peaks at later time which are associated with μd atoms reaching the cell wall after the isotopic exchange of the muon. Increasing deuterium concentration raises the rate of the isotopic muon exchange from μp to μd, which enables the μd atoms to reach the target disk faster. On the other hand, a higher concentration of deuterium in the mixture increases the probability for μd atoms to scatter with deuterium molecules. The scattering cross sections for this process exhibit no Ramsauer-Townsend minima (see Fig. 2) and can therefore limit the free path of the μd atoms. The optimal deuterium concentration which balances these concurrent effects typically lies between 0.1 and 0.25% depending on the exact target and beam conditions. Energy distributions of the muonic atoms at the moment they reach the target disk are shown in Fig. 4 for two different deuterium concentrations. As can be seen from the distributions, most μd atoms have lost the energy gained in the isotopic exchange reaction when reaching the target. A peak of the energy distribution around the Ramsauer-Townsend minimum at 4eV is visible for the lower deuterium concentration (cD=0.1%). For the higher concentration, this peak has been washed out due to the increased scattering on deuterium molecules.

Fig. 3.

Fig. 3

Time distributions of μd and μp atoms reaching the surface of the target disk for various deuterium concentrations cD. The time t corresponds to the time after the incoming muons have triggered the entrance detector. The distributions are normalized by the number of entrance counts

Fig. 4.

Fig. 4

Energy distributions of μd and μp atoms reaching the surface of the target disk for two different deuterium concentrations cD. Only atoms that reach within the first 1μs after the entrance detector has been triggered are considered here. The distributions are normalized by the number of counts in the entrance detector

Figure 5 shows a parameter scan performed with the transport simulations. Here, the efficiency of the transport process is defined as the number of muonic atoms reaching the target disk normalized by the number of muons passing through the entrance detector. For this, only muonic atoms are considered that reach the target disk within 1000 ns after entering the target cell. Note, that the transfer to the heavy nuclei in the target is not considered in the simulations. In reality and depending on the thickness of the target, only a fraction of the muonic hydrogen atoms reaching the target surface transfer the muon to the actual target nuclei, while the rest of the muons are transferred to the target backing material. For the scan, the efficiency has been determined for various beam momenta and deuterium concentrations. For this geometry, a maximal efficiency is reached with an average momentum of 27.8 MeV/c – at which point a significant fraction of the muons stop directly in the target backing material – and a deuterium concentration of 0.15%. Comparisons of simulation results with experimental data will be presented in Sect. 5 of this text.

Fig. 5.

Fig. 5

Parameter scan for the momentum of the muon beam pμ and the deuterium concentration cD. The figure of merit is the probability for muons which are detected in the entrance detector to eventually be transferred to the target disk within maximally 1 μs. In the simulations, a gaussian muon beam momentum distribution with 4% full width at half maximum was assumed

Apparatus

Figure 6 shows an overview of the apparatus and its different components, which has been discussed in parts also in Refs. [5, 4749]. The different components and the layout were developed in order to enable the method described in Sect. 2 with the central gas cell featuring a geometry and dimensions optimized through the simulation described in Sect. 3. The following subsections describe the different elements in detail.

Fig. 6.

Fig. 6

Sketch of the muX apparatus with its different components labelled. For more details see the dedicated sections

Muon beamline

The measurements were performed at the πE1 beamline in the experimental hall of PSI’s high-intensity proton accelerator HIPA [50]. A static E×B separator installed at the beginning of the experimental area allowed to reduce the electron contamination in the beam to negligible levels thereby providing a very pure negative muon beam at the chosen momentum of around 28 MeV/c. Using a slit system mounted in the beamline at a point of large dispersion allowed to adjust the momentum acceptance of the channel to around 3–4% full width at half maximum.

The apparatus was installed about 1.3 m downstream of the last quadrupole triplet of the πE1 beamline. At this position the beamspot had a size of about 10 mm (gaussian sigma) in horizontal and vertical direction. Typical rates on the muon entrance scintillator (see Sect. 4.2) located behind the beam veto scintillator (see Sect. 4.2) with an opening of 18 mm were around 20 kHz at a proton beam intensity of 2 mA.

Beam veto, muon entrance and decay-electron veto scintillators

As shown in Fig. 6, the muX apparatus employs three different plastic scintillator detectors. They are presented in Fig. 7. The first detector in beam direction is the beam veto scintillator (Fig. 7a). This is based on a 80×80 mm2 BC-404 scintillator plate with a thickness of 4 mm and a central hole with a diameter of 18 mm. It is read out on two sides by a total of 12 3×3 mm2 silicon photomultipliers (model ASD-NUV3S-P by AdvanSiD [51]) mounted on a PCB. This detector serves as an active collimator for the muon beam and vetoes against background coming down the beamline outside of the acceptance of the entrance detector.

Fig. 7.

Fig. 7

Plastic scintillator detectors used in the muX apparatus: a beam veto scintillator, b muon entrance scintillator, and c decay-electron veto scintillators. For more details see text

The beam veto detector is followed by the muon entrance detector (Fig. 7b). The detector is based on a 20×20 mm2 BC-400 scintillator foil with a thickness of 200 μm. The scintillator is glued with optical cement on a UV-transparent plexiglas frame, which in turn is coupled to 12 3×3 mm2 silicon photomultipliers as for the beam veto detector. This detector serves to provide a precise timing for the arrival of a muon in the high-pressure gas cell and to distinguish a muon from some remaining electron background in the beam through the amount of deposited energy.

The last scintillator detectors are the decay-electron veto detectors shown in Fig. 7c that surround the gas cell. These are large 180×180 mm2 EJ204 scintillator plates with a thickness of 5 mm. The light from the scintillator is collected through wavelength shifting fibers that are embedded into grooves in the scintillator plate. They guide the light to a single 3×3 mm2 silicon photomultiplier (model S13360-3050CS by Hamamatsu [52]). One of the detectors features a 35 mm diameter central hole such that it can be mounted around the tube through which the muons enter the gas cell (see Fig. 6). These decay-electron veto detectors serve to efficiently reduce the background generated in the germanium detectors (directly or indirectly) coming from muon Michel decays generating electrons with energies up to 53 MeV.

High-pressure gas cell

Figure 8 shows an overview of the high-pressure gas cell. The main body of the cell is made of aluminum. An aluminum gas line screws into the main body from the back (feeding in the gas just behind the target) and is sealed using glue (Model Stycast 2850 FT). The cell is closed towards the muon beamline by a 600 μm thick carbon fiber-reinforced polymer window that allows the muons to pass through. In order to withstand the high pressure, the window is supported by a combination of a first 4 mm thick titanium grid and a second 2 mm carbon fiber-reinforced polymer grid mounted on top. The 2 mm carbon fiber-reinforced polymer grid faces the muon beamline and greatly reduces the background from muons stopping in titanium. The grids have an open area of 74%. During measurements a transmission through this grid and window arrangement of around 60% was observed (with a variation of around ± 5% over the various experimental campaigns depending on beam setup) and thus smaller than the open area due to the divergence of the beam and stops in the window. The grids and window are pressed down by a 3 mm thick stainless steel ring with an open diameter of 20 mm. The overall gas seal is achieved by an O-ring. The cell was pressure tested up to 350 bar at which point the screws securing the stainless steel ring and titanium and carbon fiber grids are ripped out of the aluminum body.

Fig. 8.

Fig. 8

Rendered CAD image of the high-pressure gas cell with a cutout in order to show the placement of the target and the arrangement of the entrance window and supporting grids. For reference the volume between the target and entrance window has a length of 14 mm and a diameter of 30 mm. See text for more information on the different parts

A polystyrene tube (not shown in Fig. 8) extends from the stainless steel ring to the entrance detector ensuring that muons can only stop in low-Z material on their passage from the entrance detector to the gas cell. Also the inside of the gas cell is lined with a polystyrene tube removing any potential background from muonic hydrogen or deuterium atoms reaching the aluminum walls of the pressure cell.

The inner space of the gas cell has a diameter of 30 mm and a length of 20 mm. At the end of this space the target in its target holder is mounted reducing the distance between the entrance window and target surface to 14 mm, which is the available length for the muons to stop in the gas.

Hydrogen/deuterium gas system

A dedicated gas handling system was built that allows the controlled operation and mixing of gases from three different sources and the filling of the gas cell described above through an approximately 3 m long stainless steel tube with 4 mm inner diameter. It uses various absolute pressure gauges that also monitor the pressure inside the gas cell during normal operation. Before filling the gas cell with the hydrogen/deuterium mixture, the cell is flushed several times with hydrogen in order to reduce residual air contamination and impurities in the gas as much as possible.

In 2017/2018, the gas mixture was prepared by first filling the tube and gas cell with the desired pressure of deuterium and in a next step filling hydrogen up to a pressure of 100 bar. By comparing the measurements of the transfer reactions with the simulation (and later also by performing Raman spectroscopy on the deuterium/hydrogen gas mixtures), it was realized that this procedure leads to much higher and somewhat unreproducible deuterium concentrations as the filling with hydrogen compresses all the deuterium left in the filling tube into the gas cell. Due to the high pressures the diffusion times leading to an equal mixture are very high and thus no equilibrium is reached before the start of the measurements [53]. From 2019 onward, we thus switched to the use of pre-mixed gases obtained commercially.

Target

Fig. 9.

Fig. 9

Typical gold target used during the measurements described in this paper mounted in its polystyrene holder

The backing disks for the target materials are made of glassy carbon (Sigradur from HTW [54]) with a diameter of 16 mm and a thickness of 1 mm. The gold targets employed for the measurements described here were manufactured by chemical vapor deposition using the in-house facilities available at PSI.

The glassy carbon disks are mounted in a holder made of polystyrene, which as described above is fastened at the back of the gas cell using PEEK screws. The holder reduces the open area of the target to a diameter of 15 mm. In order to avoid any potential contamination of the gas in the cell the screws were vented through small holes and generally only procedures applicable for high-vacuum environments were employed during the design, construction and handling of the high-pressure gas cell.

High-purity germanium detector array

The germanium detector setups evolved over the course of the different experimental campaigns. In 2017 and 2018 (see Fig. 10), the array was mounted in a custom frame on rails and consisted of seven single-crystal coaxial detectors with 60% efficiency from the IN2P3/STFC French/UK Ge loan pool [55], two single-crystal coaxial Ge detector with 75% and 70% efficiency (an additional 15% detector was mounted in 2018), a Miniball cluster consisting of three individual crystals of around 60% each [56] and a planar detector optimized for low-energy gamma rays. The frame allowed a modest flexibility in positioning the detectors at distances of around 10 to 15 cm away from the target.

Fig. 10.

Fig. 10

Germanium detector array used during the 2017/2018 experimental campaigns

In 2019 due to the long shutdown at CERN, the full Miniball detector array [56] was brought from ISOLDE to PSI and mounted for an extended period in the πE1 area. The full array consisted of 8 clusters of three crystals with efficiencies of around 60% each. The array mounted in its original frame at PSI is shown in Fig. 11. The array was supplemented by the 70% coaxial and planar detector already used in 2017 and 2018. Due to the larger number, the detectors could only be mounted at a distance of around 15 cm to the target.

Fig. 11.

Fig. 11

Miniball germanium detector array mounted in its custom, highly adjustable frame in the πE1 area. The photograph shows the array moved backwards on a dedicated rail system in order to gain easy access to the muon entrance detector and gas cell

With these configurations, we reached about 1.8% and 2.2% full energy detection efficiency at 1332 keV with the full arrays for 2017/2018 and 2019, respectively.

Calibration

While during dedicated calibration runs a large variety of standard gamma calibration sources were used, a scheme was implemented to provide continuous calibration lines during normal muon beam operation. As shown in Fig. 6, a 100 μm thick layer of 208Pb was mounted behind a 600 μm thick carbon fiber-reinforced polymer sheet (the same as the entrance window of the gas cell) – both with a central hole of 18 mm – and installed in front of the beam veto detector with the carbon fiber-reinforced polymer sheet facing the beam. This allowed a fraction of the muon beam (those outside the 18 mm acceptance of the beam veto scintillator) to stop in 208Pb and produce a continuous source of well-known muonic x rays reaching up to high energies [57] for calibration. In addition, a weak 2.6 kBq 60Co source was placed close to the target that provided additional continuous calibration lines and could also be used for an automated analysis and check of the full detector array by monitoring for each detector the properties of the measured 60Co lines.

Results

Optimization of transfer process

The transfer process inside the gas cell is typically optimized through a series of measurements employing a 50 nm thick gold target prepared as described in Sect. 4.5. The 50 nm thickness was chosen under the assumption that such a layer would lead to the full transfer of all muons from the muonic hydrogen and deuterium atoms to gold as they penetrate into the layer. The total target mass amounts to a bit over 200 μg, which allows for swift measurements while at the same time only having a negligible amount of direct muon stops inside the gold layer. The optimization procedure basically follows the parameter space outlined in Fig. 5 by scanning the deuterium concentration and muon beam momentum and counting the amount of emitted muonic 2p-1s gold x rays at 5591.7 and 5760.8 keV (the higher energy transition is distributed across two lines due to hyperfine splitting) [4, 58].

The observed total counts of 2p-1s gold x rays Nγ is used to estimate the efficiency ϵT of the full transfer process by relating them to the number of detected muons by the entrance detector Nμ:

ϵT=NγNμ1Iϵdetζ, 6

with I the absolute yield per muon of the 2p-1s line, ϵdet the detection efficiency of the full germanium detector array at this energy and ζ the transmission through the grids and the entrance window of the gas cell (see Sect. 4.3).

The yields of the 2p-1s transition after transfer is distinctly different and about a factor 2 lower compared to direct capture as was, e.g, measured for several low-Z elements [5962]. This can be understood by the fact that the initial distribution across the angular momentum states is shifted to much lower values [63], which boosts the yields of higher np-1s transitions compared to the direct capture. As no trustworthy measurements of the 2p-1s yield after transfer for elements higher than argon exist, it was estimated for gold after transfer to be 65.7±7.1%, and thus significantly higher than seen in the measurements at lower atomic numbers, by extrapolating a series of transfer measurements in a hydrogen gas cell with small admixtures of argon, krypton and xenon. A dedicated publication on these measurements is in preparation [64].

In order to measure the detection efficiency of the germanium array at the energies of the muonic gold 2p-1s x rays, a 300 μm thick natural lead target with a diameter of 30 mm was mounted in vacuum and without the entrance window and support grids at the target position inside the gas cell. This arrangement guaranteed that any muon registered by the entrance detector hits the lead target and stops within. By using the measured yield of the 2p-1s transition BR(2p-1s)=0.899 (from gold [65] instead of lead as the corresponding values found in literature for lead [66, 67] of BR(2p-1s)0.6 are clearly not correct and as only a negligible change of the 2p-1s yields are expected for these two close, high-Z elements), the efficiency can be calculated by the ratio of detected number of x rays to the number of emitted x rays given by the number of muons multiplied by the yield:

ϵdet=NγNμ×BR(2p-1s) 7

The number of detected x rays Nγ was obtained by fitting the corresponding 2p-1s lines in the measured spectrum. Additionally and by taking full advantage of the large germanium detector array, a γ-γ coincidence analysis was performed by triggering one of the germanium detectors on the 3d-2p transition and counting the number of observed 2p-1s x rays in the rest of the detector array. The two approaches resulted in perfectly consistent values for the detector efficiency of ϵdet=(0.46±0.01)% at 5.6 MeV energy.

The window transmission ζ was measured just following the detector efficiency measurements by still employing the natural lead target, but closing the cell with the carbon fiber window and support grids and comparing the amount of emitted lead x rays per incoming muon with and without the entrance window. The extracted value amounts to ζ=54.5% and is consistent across several of the muonic lead lines.

With these parameters at hand the transfer efficiency can be calculated and plotted for the 2019 measurements as a function of deuterium concentration and beam momentum in Fig. 12, which reaches a maximum of approximately 5% at a deuterium concentration of 0.25% and a momentum of 27.25 MeV/c. The plots show the results for two different time windows of 500 and 1000 ns after the muon entrance highlighting the effect of the deuterium concentration and momentum on the speed of the transfer process to the gold target. Shown in addition to the measurements are also the results of the simulation from Fig. 5. Excellent agreement is found between the measurements and simulation suggesting good understanding of the processes occurring in the gas cell and corroborating the assumption that a 50 nm gold layer is thick enough such that all muons transfer to the target material. Good agreement between simulation and measurements is also found by plotting the time evolution of the muonic gold 2p-1s x rays as a function of time after a muon entered the gas cell–see Fig. 13.

Fig. 12.

Fig. 12

a Transfer efficiency as a function of deuterium concentration cD at a muon beam momentum of 27.25 MeV/c. b Transfer efficiency as a function of muon beam momentum p at a deuterium concentration of 0.25%. The two time windows correspond to the time after a muon entered the gas cell over which the recorded muonic gold x rays are counted to calculate the transfer efficiency. Also shown are the simulation results from Fig. 5 that demonstrate excellent agreement. In the comparisons here, the momentum of the simulated results was shifted by -0.65 MeV/c in order to compensate for the not precisely known material budget traversed by the muon beam and to obtain the maximum efficiency at the same momentum as in the measurement

Fig. 13.

Fig. 13

Evolution of the normalized muonic gold 2p-1s x rays as a function of time after a muon entered the gas cell for different deuterium concentrations: a cD=0.1%, b cD=0.25%, c cD=0.75%, and d cD=1.5%. The results from the simulation (in red) nicely agree with the measured data (in black)

Measurements with a few microgram target

Already in 2017 in a first proof-of-principle measurement, we have aimed at a measurement with only 5 μg of gold as motivated by the maximum allowed quantity for a potential 226Ra measurement. We did this in a series of measurements where the target mass was reduced from about 470 μg down to 5 μg. As we only discovered the issues with the hydrogen/deuterium mixture (as described in Sect. 4.4) later, we cannot give precise values for these series of measurements as they are plagued with uncertainty due to changes in the deuterium concentration for the different measurements, but will only give some rough estimates in the next paragraph.

In the measurement sequence we started with a 50 nm gold coating on a diameter of 25 mm (the target mount was somewhat different in these first measurements compared to the one described in Sect. 4.5) and gradually reduced it to a 3 nm coating on a 10×10 mm2 area. Each of the reductions – 50 nm to 3 nm and 491 mm2 to 100 mm2 – were accompanied by a loss in gold x rays of about a factor 3. For the final gold measurement with the 5 μg target material (3 nm coating on a 10×10 mm2), the estimated total transfer efficiency was slightly above 1%. The result of a 18.5 h long measurement with this target is shown in Fig. 14. The figure shows the measured energy spectrum versus the time after a muon entered the gas cell (Fig. 14a) and its projection on energy (Fig. 14b). Clearly visible are the peaks from the muonic 208Pb x rays used for the continuous calibration (see Sect. 4.7) that appear constant in time and the gold x rays from the target that only start to appear with the muon entering the gas cell. Additionally, the 5.5 MeV gamma ray emitted in the pμd fusion process can be seen [68].

Fig. 14.

Fig. 14

Two dimensional histogram of the measured x-ray energy versus the time after a muon entered the gas cell (a) and its projection on energy (b). Visible are the 2p1/2-1s1/2 and the single escape (S.E.) 2p3/2-1s1/2 lines from the continuous muonic 208Pb calibration source, a gamma line from pμd fusion and the muonic 2p1/2-1s1/2 and 2p3/2-1s1/2 x rays from the 5 μg gold target. The 2p3/2-1s1/2 in muonic gold shows additionally a hyperfine structure. The black line in b is a simple Gaussian fit with linear background to the 2p1/2-1s1/2 line of muonic gold. For details, see text

Figure 14 also shows a simple Gaussian fit with linear background to the 2p1/2-1s1/2 line of muonic gold. The resulting mean of the Gaussian is fitted to 5591.65(26) keV perfectly in agreement and with only slightly worse precision than the value found in literature of 5591.71(15) keV [69] demonstrating the excellent performance of the apparatus and method for such microgram target quantities. Based on this measured energy of the 2p1/2-1s1/2, one could proceed to follow the standard procedure in muonic atom spectroscopy to extract a nuclear charge radius through the matching of the measured energy with calculations that have the nuclear charge radius as a free parameter [69].

With the dominant uncertainty on any extracted, high-Z nuclear charge radius being of theoretical nature, a measurement as shown in Fig. 14 that results in transition energies of the muonic atom with 200 eV accuracy is sufficient to extract the charge radius of such high-Z elements with a relative uncertainty of a few times 10-4 [69].

Conclusion

In conclusion, we have developed a method and built an apparatus to perform muonic atom spectroscopy with targets that are only available in microgram quantities such as highly radioactive or scarce isotopically pure elements. The method relies on repeated transfer reactions taking place inside a 100 bar hydrogen gas cell with an admixture of 0.25% deuterium at room temperature. The apparatus consists of a muon entrance detector, beam and decay electron veto detectors, a high-pressure gas cell containing the target and a high-purity germanium detector array to measure the energies of the x rays emitted in the muonic cascade.

In order to optimize and understand the apparatus, a detailed simulation was developed that models all of the processes taking place inside the gas cell. A comparison of the results of the simulation with the measured data shows excellent agreement and underlines the good understanding of the transfer processes taking place in such environments.

As a proof of principle, the muonic 2p-1s x rays from a 5 μg gold target were measured showing good signal to background levels and demonstrating the ability to perform high sensitivity measurements with microgram target materials. Employing this method, we succeeded to measure 248Cm, the heaviest element ever probed with muonic atom spectroscopy [70]. A measurement of 226Ra is also within reach. Additional measurements of elements that were so far inaccessible are being planned.

Acknowledgements

We gratefully acknowledge fruitful discussions with P. Kammel that laid the basis to the development of the method presented in this paper. The experiments were performed at the πE1 beam line of PSI. We would like to thank the accelerator and support groups for the excellent conditions. Additional technical support by F. Barchetti, F. Burri, M. Hildebrandt, M. Meier, L. Noorda, A. Stoykov, and A. Weber from PSI is gratefully acknowledged.

Funding

Open Access funding provided by Lib4RI - Library for the Research Institutes within the ETH Domain: Eawag, Empa, PSI & amp; WSL. Funding was provided by FWO-Vlaanderen (Belgium), the Paul Scherrer Institute through the Career Return Program, the Cluster of Excellence “Precision Physics, Fundamental Interactions, and Structure of Matter” (PRISMA EXC 1098 and PRISMA+ EXC 2118/1) funded by the German Research Foundation (DFG) within the German Excellence Strategy (Project ID 39083149), the German Research Foundation (DFG) under Project WA 4157/1 and 407008443, the German BMBF under contracts 05P18PKCIA and ‘Verbundprojekt’ 05P21PKCI1, and the Swiss National Science Foundation through the Marie Heim-Vögtlin Grant no. 164515 and project Grant no. 200021_165569. P.I. is a member of the Allianz Program of the Helmholtz Association, contract no EMMI HA-216 “Extremes of Density and Temperature: Cosmic Matter in the Laboratory”.

Data availability statement

This manuscript has no associated data or the data will not be deposited. [Authors’ comment:The data is available from the corresponding author upon reasonable request.]

Footnotes

1

Except for transitions passing through the 2s state, which can be metastable.

2

For a definition of the transport cross section see, e.g., Ref. [24].

References

  • 1.Stanislaus S, Entezami F, Measday DF. Atomic capture of muons and density. Nucl. Phys. A. 1987;475(4):642–656. doi: 10.1016/0375-9474(87)90230-2. [DOI] [Google Scholar]
  • 2.Markushin VE. Cascade in muonic and pionic atoms with Z = 1. Hyperfine Interact. 1999;119:11. doi: 10.1023/A:1012642215730. [DOI] [Google Scholar]
  • 3.Suzuki T, Measday DF, Roalsvig JP. Total nuclear capture rates for negative muons. Phys. Rev. C. 1987;35:2212. doi: 10.1103/PhysRevC.35.2212. [DOI] [PubMed] [Google Scholar]
  • 4.Fricke G, Bernhardt C, Heilig K, Schaller LA, Schellenberg L, Shera EB, Dejager CW. Nuclear ground state charge radii from electromagnetic interactions. At. Data Nucl. Data Tables. 1995;60:177. doi: 10.1006/adnd.1995.1007. [DOI] [Google Scholar]
  • 5.Knecht A, Skawran A, Vogiatzi SM. Study of nuclear properties with muonic atoms. Eur. Phys. J. Plus. 2020;135(10):777. doi: 10.1140/epjp/s13360-020-00777-y. [DOI] [Google Scholar]
  • 6.Angeli I, Marinova KP. Table of experimental nuclear ground state charge radii: an update. At. Data Nucl. Data Tables. 2013;99(1):69–95. doi: 10.1016/j.adt.2011.12.006. [DOI] [Google Scholar]
  • 7.Angeli I, Gangrsky YP, Marinova KP, Boboshin IN, Komarov SY, Ishkhanov BS, Varlamov VV. N and Z dependence of nuclear charge radii. J. Phys. G. 2009;36(8):085102. doi: 10.1088/0954-3899/36/8/085102. [DOI] [Google Scholar]
  • 8.Frois B, Papanicolas CN. Electron scattering and nuclear structure. Ann. Rev. Nucl. Part. Sci. 1987;37:133–176. doi: 10.1146/annurev.nucl.37.1.133. [DOI] [Google Scholar]
  • 9.Cheal B, Cocolios TE, Fritzsche S. Laser spectroscopy of radioactive isotopes: role and limitations of accurate isotope-shift calculations. Phys. Rev. A. 2012;86:042501. doi: 10.1103/PhysRevA.86.042501. [DOI] [Google Scholar]
  • 10.Neugart R, Billowes J, Bissell ML, Blaum K, Cheal B, Flanagan KT, Neyens G, Nörtershäuser W, Yordanov DT. Collinear laser spectroscopy at ISOLDE: new methods and highlights. J. Phys. G. 2017;44(6):064002. doi: 10.1088/1361-6471/aa6642. [DOI] [Google Scholar]
  • 11.Groom DE, Mokhov NV, Striganov SI. Muon stopping power and range tables 10 MeV?100 TeV. At. Data Nucl. Data Tables. 2001;78(2):183–356. doi: 10.1006/adnd.2001.0861. [DOI] [Google Scholar]
  • 12.T.E. Cocolios, Absolute charge radii of radioactive isotopes measured by muonic x-ray spectroscopy at PSI. Technical report, CERN, Geneva (2020). https://cds.cern.ch/record/2717871
  • 13.Wansbeek LW, Sahoo BK, Timmermans RGE, Jungmann K, Das BP, Mukherjee D. Atomic parity nonconservation in Ra+ Phys. Rev. A. 2008;78:050501. doi: 10.1103/PhysRevA.78.050501. [DOI] [Google Scholar]
  • 14.Antognini A, Kottmann F, Pohl R. Laser spectroscopy of light muonic atoms and the nuclear charge radii. Sci. Post Phys. Proc. 2021;5:021. doi: 10.21468/SciPostPhysProc.5.021. [DOI] [Google Scholar]
  • 15.Kraiman JB, et al. Diffusion of muonic deuterium in D2 Gas. Phys. Rev. Lett. 1989;63:1942–1945. doi: 10.1103/PhysRevLett.63.1942. [DOI] [PubMed] [Google Scholar]
  • 16.Strasser P, Nagamine K, Matsuzaki T, Ishida K, Matsuda Y, Iwasaki M. Muonic atoms of unstable nuclei. AIP Conf. Proc. 2005;793(1):242–257. doi: 10.1063/1.2121987. [DOI] [Google Scholar]
  • 17.Strasser P, et al. Muon spectroscopy with trace alkaline-earth and rare-earth isotopes implanted in solid D2. Hyperfine Interact. 2009;193:121. doi: 10.1007/s10751-009-0055-0. [DOI] [Google Scholar]
  • 18.Ponomarev LI. Muon catalysed fusion. Contemp. Phys. 1990;31:219. doi: 10.1080/00107519008222019. [DOI] [Google Scholar]
  • 19.Petitjean C. The μCF experiments at PSI -a conclusive review. Hyperfine Interact. 2001;138(1):191. doi: 10.1023/A:1020883708302. [DOI] [Google Scholar]
  • 20.Korenman GY. Mechanisms and kinetics of exotic atom formation in hydrogen and helium. Hyperfine Interact. 1996;101(1):81–89. doi: 10.1007/BF02227608. [DOI] [Google Scholar]
  • 21.Andreev VA, et al. Measurement of the muon capture rate in hydrogen gas and determination of the proton’s pseudoscalar coupling gP. Phys. Rev. Lett. 2007;99:032002. doi: 10.1103/PhysRevLett.99.032002. [DOI] [PubMed] [Google Scholar]
  • 22.Mulhauser F, et al. Ramsauer-Townsend effect in muonic atom scattering. Phys. Rev. A. 2006;73:034501. doi: 10.1103/PhysRevA.73.034501. [DOI] [Google Scholar]
  • 23.Ramsauer C. Über den Wirkungsquerschnitt der Gasmoleküle gegenüber langsamen Elektronen. Ann. Phys. 1921;369(6):513–540. doi: 10.1002/andp.19213690603. [DOI] [Google Scholar]
  • 24.Adamczak A, Gronowski J. Diffusion radius of muonic hydrogen atoms in h-d gas. Eur. Phys. J. D. 2007;41(3):493. doi: 10.1140/epjd/e2006-00252-6. [DOI] [Google Scholar]
  • 25.Adamczak A, et al. Atlas of cross sections for scattering of muonic hydrogen atoms on hydrogen isotope molecules. Atom. Data Nucl. Data Tables. 1996;62:255. doi: 10.1006/adnd.1996.0006. [DOI] [Google Scholar]
  • 26.Gershtein SS. Sov. Phys. JETP. 1962;16:501. [Google Scholar]
  • 27.Ponomarev LI, Puzynina TP. The two-center problem in quantum mechanics. Sov. Phys. JETP. 1967;25:846. [Google Scholar]
  • 28.Fiorentini G, Torelli G. Muon transfer to heavy atoms: a probe for the study of the (μp)2s System. Nuovo Cim. A. 1976;36:317–330. doi: 10.1007/BF02724519. [DOI] [Google Scholar]
  • 29.Bracci L, Fiorentini G. Meson transfer to atoms and molecules. Nuovo Cim. A. 1979;50:373. doi: 10.1007/BF02813242. [DOI] [Google Scholar]
  • 30.Ponomarev LI, Somov LN, Faifman MP. A simple approach to the description of the three-body system in the physics of mesic atoms. Sov. J. Nucl. Phys. 1979;29:67. [Google Scholar]
  • 31.Bracci L , Chiccoli C, Fiorentini G, Melezhik VS, Pasini P, Ponomarev LI, Wozniak J. The atlas of the cross sections of mesic atomic process I. The processes pμ+p,dμ+d and tμ+t. Muon Catal. Fusion. 1989;4:247. [Google Scholar]
  • 32.Bracci L, Chiccoli C, Fiorentini G, Melezhik VS, Pasini P, Wozniak J. Calculation of the elastic scattering cross sections for pμ+p and tμ+t collisions in adiabatic representation. Phys. Lett. A. 1990;149:463. doi: 10.1016/0375-9601(90)90218-D. [DOI] [Google Scholar]
  • 33.M. Bubak, M.P. Faifman, Cross sections for hydrogen muonic atomic processes in two-level approximation of the adiabatic framework. JINR Preprint E4-87-464 (1987)
  • 34.Adamczak A . Differential cross sections for muonic atom scattering from hydrogenic molecules. Phys. Rev. A. 2006 doi: 10.1103/PhysRevA.74.042718. [DOI] [Google Scholar]
  • 35.Agostinelli S, et al. Geant4?a simulation toolkit. Nucl. Instrum. Methods Phys. Res. Sect. A. 2003;506(3):250–303. doi: 10.1016/S0168-9002(03)01368-8. [DOI] [Google Scholar]
  • 36.T.J. Roberts, D.M. Kaplan, G4beamline simulation program for matter-dominated beamlines. In: 2007 IEEE Particle Accelerator Conference (PAC), pp. 3468–3470 (2007)
  • 37.Leon M, Bethe HA. Negative meson absorption in liquid hydrogen. Phys. Rev. 1962;127:636. doi: 10.1103/PhysRev.127.636. [DOI] [Google Scholar]
  • 38.Borie E, Leon M. X-ray yields in protonium and mesic hydrogen. Phys. Rev. A. 1980;21:1460. doi: 10.1103/PhysRevA.21.1460. [DOI] [Google Scholar]
  • 39.Markushin VE. Atomic cascade in muonic hydrogen and the problem of kinetic-energy distribution in the ground state. Phys. Rev. A. 1984;50:1137. doi: 10.1103/PhysRevA.50.1137. [DOI] [PubMed] [Google Scholar]
  • 40.Jensen TS, Markushin VE. Collisional deexcitation of exotic hydrogen atoms in highly excited states. Eur. Phys. J. D. 2002;21:271. doi: 10.1140/epjd/e2002-00208-x. [DOI] [Google Scholar]
  • 41.M.P. Faifman, L.I. Men’shikov, Study of cascade processes in pμ and pK- atoms based on a new approach. In: Proceedings of International Conference on Muon Catalyzed Fusion and Related Topics (μCF-07), JINR, Dubna, p. 233 (2008)
  • 42.Popov VP, Pomerantsev VN. Kinetic energy distributions of muonic and pionic hydrogen atoms. Hyperfine Interact. 2012;209:75. doi: 10.1007/s10751-011-0514-2. [DOI] [Google Scholar]
  • 43.Popov VP, Pomerantsev VN. Isotopic effects in scattering and kinetics of the atomic cascade of excited μ-p and μ-d atoms. Phys. Rev. A. 2017;95:022506. doi: 10.1103/PhysRevA.95.022506. [DOI] [Google Scholar]
  • 44.Popov VP, Pomerantsev VN. Collision-induced radiative quenching and other disintegration modes of the 2s state of muonic hydrogen and deuterium atoms. Phys. Rev. A. 2022;105:042804. doi: 10.1103/PhysRevA.105.042804. [DOI] [Google Scholar]
  • 45.Abbott DJ, et al. Diffusion of muonic deuterium and hydrogen atoms. Phys. Rev. A. 1997;55:214. doi: 10.1103/PhysRevA.55.214. [DOI] [Google Scholar]
  • 46.Pohl R, et al. The size of the proton. Nature. 2010;466:213. doi: 10.1038/nature09250. [DOI] [PubMed] [Google Scholar]
  • 47.Adamczak A, Antognini A, Berger N, Cocolios TE, Dressler R, Eggenberger A, Eichler R, Indelicato P, Jungmann K, Kirch K, Knecht A, Papa A, Pohl R, Pospelov M, Rapisarda E, Reiter P, Ritjoho N, Roccia S, Severijns N, Skawran A, Wauters F, Willmann L. Nuclear structure with radioactive muonic atoms. EPJ Web Conf. 2018;193:04014. doi: 10.1051/epjconf/201819304014. [DOI] [Google Scholar]
  • 48.Skawran A, et al. Towards nuclear structure with radioactive muonic atoms. Nuovo Cim. 2019;42:125. doi: 10.1393/ncc/i2019-19125-7. [DOI] [Google Scholar]
  • 49.Wauters F, Knecht A. The muX project. Sci. Post Phys. Proc. 2021;5:022. doi: 10.21468/SciPostPhysProc.5.022. [DOI] [Google Scholar]
  • 50.Grillenberger J, Baumgarten C, Seidel M. The high intensity proton accelerator facility. Sci. Post Phys. Proc. 2021;5:002. doi: 10.21468/SciPostPhysProc.5.002. [DOI] [Google Scholar]
  • 51.AdvanSiD. (2022). https://advansid.com/. Accessed 09 Sep 2022
  • 52.Hamamatsu. (2022). https://www.hamamatsu.com. Accessed 09 Sep 2022
  • 53.J. Nuber, Simulation of the diffusion process of muonic atoms in hydrogen targets. Master’s thesis, Karlsruhe Intitute of Technology (2018)
  • 54.HTW Hochtemperatur-Werkstoffe GmbH. (2022). http://htw-germany.com. Accessed 20 Sep 2022
  • 55.IN2P3/STFC French/UK Ge Pool. (2022). https://gepool.in2p3.fr. Accessed 20 Sep 2022
  • 56.Warr N, et al. The Miniball spectrometer. Eur. Phys. J. A. 2013;49(3):40. doi: 10.1140/epja/i2013-13040-9. [DOI] [Google Scholar]
  • 57.Bergem P, et al. Nuclear polarization and charge moments of 208Pb from muonic x rays. Phys. Rev. C. 1988;37:2821. doi: 10.1103/PhysRevC.37.2821. [DOI] [PubMed] [Google Scholar]
  • 58.Acker HL, Backenstoss G, Daum C, Sens JC, De Wit SA. Measurement and analysis of muonic x-ray spectra in spherical nuclei. Nucl. Phys. 1966;87:1. doi: 10.1016/0029-5582(66)90355-5. [DOI] [Google Scholar]
  • 59.Bertin A, Ferrari F, Massa I, Piccinini M, Vannini G, Vitale A. Muon transfer effect on the Lyman series of μAl muonic atoms. Phys. Lett. A. 1978;68:201. doi: 10.1016/0375-9601(78)90803-4. [DOI] [Google Scholar]
  • 60.Jacot-Guillarmod R, Bienz F, Boschung M, Piller C, Schaller LA, Schellenberg L, Schneuwly H, Reichart W, Torelli G. Muon transfer from hydrogen to argon and helium at 10–15 bars. Phys. Rev. A. 1988;38:6151. doi: 10.1103/PhysRevA.38.6151. [DOI] [PubMed] [Google Scholar]
  • 61.F. Mulhauser, H. Schneuwly, Muon transfer to sulphur dioxide. J. Phys. B 26, 4307 (1993). 10.1088/0953-4075/26/22/032
  • 62.R. Jacot-Guillarmod, Muon transfer from hydrogen and deuterium atoms to neon. Phys. Rev. A 51, 2179 (1995). 10.1103/PhysRevA.51.2179 [DOI] [PubMed]
  • 63.Haff PK, Rodrigo E, Tombrello TA. Muon transfer in gas targets. Ann. Phys. 1977;104:363. doi: 10.1016/0003-4916(77)90336-0. [DOI] [Google Scholar]
  • 64.Skawran A . Development of a new method to perform muonic atom spectroscopy with microgram targets, PhD thesis. ETH Zürich. 2021 doi: 10.3929/ethz-b-000489410. [DOI] [Google Scholar]
  • 65.Hartmann FJ, Bergmann R, Daniel H, et al. Measurement of the muonic x-ray cascade in Mg, AI, In, Ho, and Au. Z. Phys. A. 1982;305:189. doi: 10.1007/BF01417434. [DOI] [Google Scholar]
  • 66.Butsev VS, et al. Intensities of muonic X rays in lead, thorium and uranium. JETP Lett. 1976;23:491. [Google Scholar]
  • 67.Anderson HL, Hargrove CK, Hincks EP, McAndrew JD, McKee RJ, Barton RD, Kessler D. Precise measurement of the muonic X rays in the lead isotopes. Phys. Rev. 1969;187:1565. doi: 10.1103/PhysRev.187.1565. [DOI] [Google Scholar]
  • 68.Friar JL, Gibson BF, Jean HC, Payne GL. Nuclear transition rates in μ-catalyzed p-d fusion. Phys. Rev. Lett. 1991;66:1827. doi: 10.1103/PhysRevLett.66.1827. [DOI] [PubMed] [Google Scholar]
  • 69.Fricke G, Heilig K. Nuclear Charge Radii. Berlin Heidelberg: Springer-Verlag; 2004. [Google Scholar]
  • 70.S.M. Vogiatzi, Muonic atom spectroscopy with radioactive targets. Talk at the 2022 Swiss Physical Society meeting: https://indi.to/jCk85 (2022)

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Data Availability Statement

This manuscript has no associated data or the data will not be deposited. [Authors’ comment:The data is available from the corresponding author upon reasonable request.]


Articles from The European Physical Journal. A, Hadrons and Nuclei are provided here courtesy of Springer

RESOURCES