Skip to main content
Therapeutics and Clinical Risk Management logoLink to Therapeutics and Clinical Risk Management
. 2023 Feb 3;19:143–162. doi: 10.2147/TCRM.S358737

Adherence to Continuous Positive Airway Pressure Therapy in Pediatric Patients with Obstructive Sleep Apnea: A Meta-Analysis

Bundit Sawunyavisuth 1, Chetta Ngamjarus 2, Kittisak Sawanyawisuth 3,
PMCID: PMC9904217  PMID: 36761690

Abstract

Introduction

Obstructive sleep apnea (OSA) is a public health problem that affects children. Although continuous positive airway pressure (CPAP) therapy is effective, the CPAP adherence rate in children is varied. This study aimed to evaluate the CPAP adherence rate and factors associated with CPAP adherence in children with OSA using a systematic review.

Methods

The inclusion criteria were observational studies conducted in children with OSA and assessed adherence of CPAP using objective evaluation. The literature search was performed in four databases. Meta-analysis using fixed-effect model was conducted to combine results among included studies.

Results

In all, 34 studies that evaluated adherence rate and predictors of CPAP adherence in children with OSA were included, representing 21,737 patients with an average adherence rate of 46.56%. There were 11 calculations of factors predictive of CPAP adherence: age, sex, ethnicity, body mass index, obesity, income, sleep efficiency, the apnea-hypopnea index (AHI), severity of OSA, residual AHI, and lowest oxygen saturation level. Three different factors were linked to children with adherence and non-adherence to CPAP: age, body mass index, and AHI.

Conclusion

The CPAP adherence rate in children with OSA was 46.56%. Young age, low body mass index, and high AHI were associated with acceptable CPAP adherence in children with OSA.

Keywords: age, body mass index, apnea-hypopnea index

Introduction

Obstructive sleep apnea (OSA) is a public health problem in children. A review reported a prevalence rate of pediatric OSA that varied among countries with a range of 0.1% (Singapore) to 13.0% (Italy).1 A report from China found that the prevalence of OSA may be as high as 63.9% of 1578 children between 2 and 15 years of age with snoring.2 OSA is reported to be more common in children with certain conditions such as obesity, allergic rhinitis, or Down syndrome.3–6 The prevalence of OSA among children with obesity was 4.9 times higher than among non-obese children (44.6% vs 9.1%; p = 0.0002).6 If left untreated, OSA in children increases their risks for neurocognitive dysfunction, abnormal behavior, and cardiovascular diseases such as hypertension or left ventricular hypertrophy.7,8

Continuous positive airway pressure (CPAP) is recommended for children with OSA if adenotonsillectomy is not performed or OSA is unresolved after this surgery.9 A prospective study among children with OSA found that CPAP provided immediate and sustained improvement of OSA over a one-year period.10 Scores on the Epworth Sleepiness Scale improved significantly at one year from baseline (14.44 to 7.86; p = 0.001).10 However, information regarding the cardiovascular impact of OSA in children is lacking and evidence of CPAP benefits is quite limited.

A known problem with CPAP therapy is adherence. A previous systematic review of 46 included studies found that the average adherence rate from 20 studies (1079 participants) was 56.9% (range of 24–87%). Note that, for this systematic review, the average age of participants was 9.4 years with a range of 0.5–16 years; 34 studies had participants with developmental delays. Several factors were found to be associated with poorer CPAP adherence, including age (five studies), sex (two studies), race (one study), body mass index (BMI) (one study), and developmental delay (two studies).11 However, this systematic review was reported as a scoping review without summarized calculation according to meta-analysis style.

Another meta-analysis on this topic published in 2020 with the final search in 2019 identified five factors calculated as predictors of CPAP adherence in children with OSA.12 Studies conducted on non-invasive ventilator or a randomized controlled trial were included, resulting in an ability to report the CPAP adherence rate for children with OSA.13,14 Additionally, the adherence rate was not reported. As the previous meta-analysis did not report the CPAP adherence rate with a gap of three years and limited predictors, this study aimed to evaluate the adherence rate and add more calculations regarding predictors of CPAP adherence in children with OSA by updating the search.

Methods

This was an update to a meta-analysis study to evaluate factors predictive of adequate CPAP adherence in children with OSA. The study was registered at PROSPERO (ID: CRD42022346132).

Eligibility Criteria

Population

This study included studies conducted among children with OSA. It evaluated CPAP adherence using objective evaluation regardless of types of CPAP device, CPAP company, adherence criteria, inclusion criteria, or other factors such as age, sex, or co-morbid diseases. The CPAP devices used to treat OSA in children were standard CPAP, automatic CPAP (APAP), or bilevel positive airway pressure (BPAP). The details regarding each device have been reported elsewhere.15

Intervention and Control Group

This study did not evaluate any type of intervention to assist CPAP use in children with OSA. We mainly evaluated personal and laboratory factors associated with CPAP adherence in children with OSA who experienced CPAP therapy. Those who adhered to CPAP therapy (studied group) were compared with those who did not (control group). The diagnosis of OSA is based on polysomnography with an apnea-hypopnea index (AHI) of 1/hour or higher.2 During polysomnography, the lowest oxygen saturation level while asleep was reported as a percentage, and sleep efficiency percentage was reported defined as the total sleep time divided by the total time in bed during polysomnography. After treatment with CPAP, adherence data were downloaded either from the device or cloud technology.

Outcomes

The outcomes of the study were overall CPAP adherence rate and factors predictive of adequate CPAP adherence in children with OSA.

Study Types

The study types included in this study were any observational studies. Those studies with intervention, stimulation, no adherence data, non-CPAP or non-BPAP, non-objective data on adherence were excluded as were case reports/case series, commentaries, books, abstracts, and reviews.

Search Strategy

Four databases were used for systematic searching including PubMed, Central database, Scopus, and CINAHL Plus. Hand-searching for related studies was also conducted. Search terms included OSA, adherence, CPAP, and bilevel positive airway pressure (BPAP/BiPAP). The full list of search terms is shown in the Appendix. The final search was conducted on August 31, 2022.

Selection Process

After the removal of duplicates, initial screening was conducted for non-relevant articles. Only pediatric studies were eligible and were included if factors predictive of adequate CPAP adherence were evaluated. The initial screening process was performed independently by two authors (BS, KS). Studies selected by each reviewer were compared and entered in the full-text review process. Data extraction and full-text reviews were performed independently by two authors (BS, KS) using a priori form. Any disagreements between the authors were reviewed and decided by a third reviewer (CN). A Prima flowchart of article searching and included studies is illustrated in Figure 1.

Figure 1.

Figure 1

A Prima flowchart for adherence rate and predictors adherence of a positive airway pressure machine (CPAP) in pediatric patients with obstructive sleep apnea.

Data Collection

Data collection for each included study was retrieved for the following: publication characteristics, study characteristics, outcome characteristics, and predictor characteristics. The publication characteristics comprised the first author, year of publication, and country of study origin, while study characteristics comprised the study aim and design; age, sex, comorbidities (if any), and AHI; and duration of CPAP use. The outcome characteristics included method of assessment of CPAP adherence, definition of adherence, numbers of total cases, numbers of cases in adherence group, and numbers of cases in non-adherence group. For predictor characteristics, numbers and percentages of each potential predictor in the adherence and non-adherence groups were tabulated.

Data Analysis

There were two groups in this study: an adherence and a non-adherence group. Differences between both groups were computed for CPAP adherence. Mean differences with 95% confidence interval (CI) of numerical factors between both groups were calculated, while odds ratio with 95% CI of categorical factors between both groups were executed. I2 statistic was used to measure heterogeneity among the results of included studies. Substantial heterogeneity was identified when I2 was greater than 75%. Fixed-effect model was used to perform meta-analysis when I2 was less than 75%. Random-effects model was used to combine the results of included studies when substantial heterogeneity was found. A forest plot of each factor was created to show differences between both groups. All analyses were performed by Review Manager 5.4 (RevMan).

Risk of Bias

Study quality of observational studies including retrospective, prospective, and cross-sectional studies was evaluated using the Newcastle-Ottawa Scale (NOS), which was adapted for cross-sectional studies and applied to evaluate study quality.16 Details of the scale have been described elsewhere.16,17 Study quality is categorized as very good, good, satisfactory, and unsatisfactory. Risk of bias was performed by two authors independently (BS, CN). A disagreement between authors was reviewed and decided by a third reviewer (KS).

Results

There were 232 studies related to adherence to CPAP in patients with OSA after duplicate studies were removed (Figure 1). Of these, 50 were eligible for a full-text review and 16 of them were excluded because they were intervention studies (nine), had no objective adherence assessment (two), were based on non-invasive ventilation (two), were non-OSA (one), had no objective adherence data (one), or were conducted with adults (one). Thus, 34 studies remained that evaluated adherence in children with OSA; these were published from 2011 to 2022 (Tables 1–4).18–51 Of these 34, 12 studies had compared those who were adherent with those who were not and had applied a meta-analysis calculation (Tables 3 and 4).40–51 Most of the 34 studies were conducted in North America (23 of 34 studies) and had a retrospective study design (20 of 34 studies). The longest duration for CPAP adherence evaluation was four years22 with an average duration of 10.04 (SD 9.82) months.

Table 1.

Characteristics of Pediatric Studies with Obstructive Sleep Apnea (OSA) on Compliance of a Continuous Positive Airway Pressure Machine (CPAP): Included Studies but Not in a Meta-Analysis

Study Year Country Study Aim Study Design Age Male Sex/Total Comorbidities AHI (events/hour)a Factors of Interest
Bhattacharjee18 2020 USA Find adherence patterns of CPAP therapy Cross-sectional 4–18 years NA NA NA Age group, residual apnoea–hypopnoea index, use and onset of patient engagement programmes, PAP pressure, and nightly median PAP mask leak
Blinder19 2021 Canada Factors associated with CPAP adherence Retrospective cohort 8–17 years 80/104 (77%) Developmental delay, obesity, asthma, mental health disorder, behavioral disorder 11 (5–23) age, sex, SDB diagnosis, CPAP mode, comorbidities, PSG indices, sleep symptoms
Cielo20 2021 USA Compare CPAP in infant vs school-age children Retrospective 6 months-10 years 95/150 (63.3%) Obesity, craniofacial abnormality, neurologic abnormality, Down syndrome 25.7 (17.8–35.9) infant vs 12.1 (7.6–21.5) school-aged Infant vs school-aged
Castorena-Maldonado21 2008 Mexico Preoperative compliance Prospective 4–7 years 37/48 (77%) Obesity RDI 63 (50–80) Body weight, type of CPAP
Com22 2015 USA Characters and surgical outcomes Retrospective cohort NA 87/143 (61%) Obesity 17.7 (8.3–37.2) AHI, PSG parameters
DiFeo23 2012 USA Factors associated with CPAP adherence Prospective 2–16 years 38/56 (68%) Genetic syndrome, central nervous system abnormality, craniofacial syndrome, pulmonary disease, growth hormone deficiency, neurodevelopmental disability 19 (16) Age, sex, obesity, AHI, CPAP mode, maternal education, race, developmental delay, social support, child behavior, parental stress, nasal symptoms
Elder24 2022 New Zealand Long term CPAP outcome Retrospective NA 52/70 (70%) OSA (82%), obesity, Down syndrome, craniofacial abnormality, cerebral palsy, chromosomal abnormality, nasal obstruction, muscular dystrophy, Prader-Willi syndrome, CNS lesion, asthma, chronic lung disease, subglottic stenosis NA Periods of offered CPAP
Kang25 2019 USA Factors associated with CPAP adherence in children with developmental disabilities Retrospective 0–18 years 141/240 (58.8%) Developmental disabilities 18 (10.9–51.8)*, 12.9 (9.4–18.5)** Developmental disabilities
Katz26 2017 Canada Prevalence of cardiometabolic disease, CPAP and cardiometabolic markers Prospective 8–16 years 22/27 (81.5%) Obesity 15.5 (7.4–25.2) BMI, CPAP mode
Machaalani27 2016 Australia Factors associated with CPAP/BPAP adherence Retrospective 0–18 years 63/99 (63.6%) Chromosomal syndrome, neuromuscular, lung disorder, central nervous system 21.2 (21.5) BPAP; 24.9 (22.8) CPAP Age, gender, BMI, AHI, duration of CPAP, CPAP pressure
Marcus28 1995 USA Safety and efficacy of CPAP Retrospective NA 64% Obesity, craniofacial anomalies, Down syndrome, neuromuscular disease, mental retardation/cerebral palsy, pharyngeal flap surgery, Arnold-Chiari malformation NA Age, CPAP device, frequent clinic visit, professional counseling, parental neglect
Mulholland29 2021 Australia CPAP adherence in children between remote APAP vs fixed CPAP Retrospective > 3 years 67/87 (77.0%) Down syndrome, cerebral palsy, craniofacial syndromes 14.3 (9.5–34.9) CPAP; 23.3 (13.3–52.0) APAP APAP vs CPAP
O’Donnell30 2006 Canada Compliance rate Retrospective cohort 6 months-18 years 67/79 (84.8%) Down syndrome, developmental delay, obesity, cerebral palsy, Pierre-Robin syndrome, tumor, seizure, neuromuscular disease, Tetralogy of Fallot, Klippel-Feil syndrome, Marfan syndrome, bipolar disorder, severe asthma 11.2 Behavioral modification and parental commitment
Perriol31 2019 France Ambulatory CPAP and its adherence Prospective NA 59/78 (75.6%) Neurocognitive dysfunction 12.2 (10.6) Age, AHI, education level, neurocognitive disorders
Puri32 2016 USA Factors associated with CPAP adherence Retrospective < 18 years 34/56 (60%) Obesity, genetic syndrome, central nervous system abnormality, craniofacial syndrome, neurodevelopmental disability, attention deficit hyperactivity disorder, asthma, allergic rhinitis, post-adenotonsillectomy 25.2 (28.7) Family member on CPAP therapy
Ramirez33 2013 France Predictors of CPAP or NIV adherence NA 2–18 years NA OSA (82%), lung disease, neuromuscular disease NA Type of interface
Trucco34 2018 UK Types of sleep disordered breathing and adherence to respiratory support Retrospective < 18 years 34/60 (56.7%) Down syndrome 11.1 (4.4–24.9) n = 42 Oxygen therapy, CPAP, NIV
Uong35 2007 USA CPAP effectiveness and adherence in students Retrospective > 7 years 26/46 (56.5%) Obesity, Down syndrome, myelomeningocele, Asperger syndrome, autism, Chiari malformation, Prader-Willi syndrome, allergic rhinitis, cerebral palsy, developmental delay, fragile X, muscular dystrophy, otopalatodigital syndrome, Toureete’s syndrome 28.4 (31.8) AHI, CPAP mode, PSG parameters, OSA symptoms
van den Broek36 2021 Netherlands Adherence to CPAP in children with intellectual disabilities Prospective cohort, subgroup 1–18 years 4/9 (44.4%) Intellectual disabilities, autism spectrum disorder, attention deficit hyperactivity disorder, challenging behavior, epilepsy 21.9 (18.6) Age group
Weiss37 2021 USA Factors associated with CPAP adherence Retrospective 1 month-18 years 152/250 (61%) Down syndrome, developmental delay, obesity 22.8 (28) IQR BMI, AHI, CPAP setting, adenotonsillectomy
Willis38 2022 USA PSG titration and CPAP prescription; adherence of CPAP before and after PSG titration Retrospective NA 77/121 (64%) Obesity, allergic rhinitis, asthma, Down syndrome, attention deficit disorder, depression, gastroesophageal reflux, seizure, hypertension, developmental delay, Asperger syndrome, cardiac diagnoses, neuromuscular disease, cerebral palsy, Prader-Willi, diabetes, hypothyroidism, unspecified behavioral issue, anxiety, upper-airway anomalies, obsessive-compulsive disorder, spina bifida, adjustment disorder, eating disorder 20.1 (11–34) PSG titration
Xanthopoulos39 2017 USA Perceptions of OSA, self-efficacy on CPAP use Retrospective NA 95/141 (67.4%) Obesity, genetic disorder, craniofacial anomaly, CNS abnormality 13.8 (7.1, 29.7) Caregiver-reported and patient-reported perception, self-efficacy on CPAP use

Notes: aMean (SD) or median (1st-3rd interquartile range: IQR); *Indicating children with developmental disabilities; **Indicating typically developing children.

Abbreviations: NA, not available; NAFLD, nonalcoholic fatty liver disease; MPS, mucopolysaccharidosis; NIV, non-invasive ventilator; BPAP, bilevel positive airway pressure; APAP, automatic CPAP; AHI, mean or median (IQR); SDB, sleep-disordered breathing; BMI, body mass index; RDI, respiratory disturbance index; PSG, polysomnography; CNS, central nervous system.

Table 2.

Characteristics and Outcomes of Pediatric Studies with Obstructive Sleep Apnea (OSA) on Compliance of a Continuous Positive Airway Pressure Machine (CPAP): Included Studies but Not in a Meta-Analysis

Study Devices Data Criteria for Adherence Duration of CPAP Use Total Cases, n Adherence, n (%)
Bhattacharjee18 AirSense 10 or AirCurve 10; ResMed Airview: cloud technology Usage >4 h/night for >70% of nights 90 days 20,553* 9504 (46.3%)
Blinder19 NA Device download and clinic note Use of >4 h/night for >70% of the nights 6 months 104* 46 (51%)
Castorena-Maldonado20 Resmed S7 Spirit or Americas Device download NA 8–71 days 48* 26/48 (54%) 4 h usage
Cielo21 Philips Respironics Device download Percentage of night usage >4 h 63–110 days 150 76.5% of nights (infants), 61.2% of nights (school-aged children)
Com22 NA Device download Usage >4 h/night for >70% of nights 4 years 36* 4 (11%)
DiFeo23 Philips Respironics Device download Night used, and duration of used 3 months 56 Night used 19 (9) night/month; duration 2.8 (2.7) h/night
Elder24 NA Clinical data Usage >4 h/night for >70% of nights NA 74* 25 (34%)
Kang25 APAP, CPAP, BPAP of Philips Respironics EncoreAnywhere web-based Percentage of nights used, h of usage on nights used 6 months 177 73/81 (90%) for DD, 68/96 (70.7%) for TD
Katz26 NA Device download Use of >4 h/night for >50% of the nights 12 months 16* 11 (68.8%)
Machaalani27 Philips Respironics; ResMed Device download Usage >4 h/night, 70% of nights 12 months 99; 55 CPAP, 44 BPAP* 41/55 (75%) CPAP; 40/44 (91%) BPAP
Marcus28 Varied Device download 50% of the hour prescribed 1 year 94 82 (87%)
Mulholland29 RemStar Auto, Respironics; Fisher & Pakel or ResMed for fixed CPAP Device download Usage >4 h/night for >70% of nights 90 days 87* 21/61 (34%) APAP; 7/26 (27%) fixed CPAP
O’Donnell30 Aria LX, REMstar Pro Device download Day used and hour used 46 months 65 50 available: 76% used half night and 52% used 75% (26/50)
Perriol31 NA CPAP machine Mean CPAP use, h 24 month 34 7.0 (2.7) h/night**
Puri32 Philips Respironics EncoreAnywhere Hours of night used 3 months 56 4.8 (0.6) h: family; 3.8 (0.4) no family
Ramirez33 VPAP IV & S9, ResMed; Trilogy 100, Respironics; ICON, Fisher & Paykel Device download Usage >8 h/night NA 62* 45 (72%)
Trucco34 NA Device download Usage >4 h/night for >50% of nights 1.9 years 18* 7 (39%)
Uong35 NA Device download and parent report Use of >4 hours per night of use and >5 nights per week 18.1 months (average) 27* 19 (70.4)
van den Broek36 NA Device download Use of >4 h/night for >70% of the nights 8 months 9* 6 (66.7%)
Weiss37 NA Device download Average hours and percentage of CPAP use NA 250 4.4 (5.8) h/night; 65.8% day used
Willis38 NA Device download Usage >4 h/night NA 107* 81 (76%)
Xanthopoulos39 Philips Respironics Device download Average use >20 minutes/night 1 month 70 50 (79%), total used on days used (269.7 minutes)

Notes: *For adherence rate; **At 24 months.

Abbreviations: NA, not available; APAP, automatic CPAP; BPAP, bi-level positive airway pressure machine; h, hours; DD, children with developmental disabilities; TD, typically developing children.

Table 3.

Characteristics of Pediatric Studies with Obstructive Sleep Apnea (OSA) on Compliance of a Continuous Positive Airway Pressure Machine (CPAP): Included Studies for a Meta-Analysis

Study Year Country Study Aim Study Design Age Male Sex/Total Comorbidities AHI (Events/Hour)a Factors of Interest
Alebraheem40 2018 Canada Find predictors and barriers for CPAP Qualitative 11–17 years 13/21 (61.9%) Obesity, Chiari malformation, renal transplant, sickle cell diseases, narcolepsy, NAFLD, MPS, mitochondrial disease 14.1 (13.9) Restriction of the tubing, the discomfort of the mask, and concerns with its size and weight
Avis41 2019 USA CPAP therapy and pedestrian injury Prospective 8–16 years 17/29 (58.6%) Obesity 10.7 (15.0) CPAP improved daytime functioning
Beebe42 2011 USA CPAP and academic function Prospective 10–16 years 9/13 (69.2%) Obesity 10.0 (6.8)*
9.3 (5.7)**
Academic grade, vigilance, academic quality of life
Hawkins43 2016 USA Factors associated with CPAP adherence Retrospective NA 76/140 (52.3%) NA 20.3 (26.8)*,
16.5 (21.2)**
Female sex and developmental delay
Katz44 2020 Canada Factors associated with CPAP adherence in children with obesity Prospective, substudy 8–16 years 13/14 (92.9%) Obese, moderate to severe OSA 12.2 (7.1–36.4) Age, AHI, lowest oxygen saturation, highest carbon dioxide
Lynch45 2019 USA Evaluated CPAP adherence on quality of life Prospective, substudy 8–16 years with caregiver 16/25 (64.0%) NA 13.15 (19.58)*, 10.45 (7.62)** CPAP adherence improved quality of life
Nathan46 2013 Singapore Factors associated with CPAP adherence Retrospective 8–13 years 36/51 (70.6%) Obesity, asthma, allergic rhinitis, large tonsils/adenoids, neurodevelopmental delay, chronic lung disease, cardiovascular disease, neuromuscular disease 24.75 (6.7–53.8)*,
12.5 (5.7, 29.2)**
Female gender and asthma
Nixon47 2011 Australia Factors associated with CPAP adherence Retrospective NA 21/30 (70.0%) Down syndrome, craniofacial syndrome, intellectual disability NA Usage in the first week
Prashad48 2013 USA Factors associated with CPAP adherence Qualitative 12–18 years 15/21 (71.4%) Obesity, developmental disabilities 25.4 (24.6) Adolescent and family experience
Roberts49 2016 USA CPAP use and facial change Retrospective cohort 0–18 years 57/100 (57%) NA 17.61 (19.80)*, 12.03 (19.12)** CPAP may change facial growth
Simon50 2012 USA Factors associated with CPAP adherence Cross-sectional 8–17 years NA Obesity 22.59 (25.48)*, 14.63 (19.28)** Age, OSA symptoms
Tovichien51 2022 Thailand CPAP versus APAP adherence Prospective NA 17 (63%) Obesity, Duchenne muscular diseases, allergic rhinitis, Down syndrome, asthma 24 (19) Age, sex, AHI, oronasal mask, lower maternal education, discomfort from CPAP, lack of clinical benefits

Notes: aMean (SD) or median (1st-3rd quartile range); *Indicating adherent group; **Indicating non-adherent group.

Abbreviations: NA, not available; NAFLD, nonalcoholic fatty liver disease; MPS, mucopolysaccharidosis; APAP, automatic CPAP.

Table 4.

Characteristics and Outcomes of Pediatric Studies with Obstructive Sleep Apnea (OSA) on Compliance of a Continuous Positive Airway Pressure Machine (CPAP): Included Studies for a Meta-Analysis

Study Devices Data Criteria for Adherence Duration of CPAP Use Total Cases, n Adherence, n (%) Non-Adherence, n (%)
Alebraheem40 NA Device download Usage >4 h/night for >50% of nights 3–12 months 14 6 (42.9%) 8 (57.1%)
Avis41 NA Device download Usage >4 h/night 3 months 20 11 (55%) 9 (45%)
Beebe42 NA Parent report Percent of sleep time with CPAP >21% 4 months 13 7 (53.8%) 6 (46.2%)
Hawkins43 NA DME providers Usage >4 h/night for >70% of nights >1 year 140 69 (49%) 71 (51%)
Katz44 CPAP (42.9%), BPAP (57.1%) Machine download Usage >4 h/night for >50% of nights 1 year 14 11 (78.6%) 3 (21.4%)
Lynch45 ResMed Smartcards Usage >4 h/night for >50% of nights 3 months 25 15 (60%) 10 (40%)
Nathan46 CPAP (92.2%), BPAP (7.8%) Case note >4 days/week 6 months 51 21 (41.2%) 68 (37%)
Nixon47 Fisher and Paykel Healthcare, ResMed Device download Use >1 h/night for >6 nights/week 3 months 30 10 (33.3%) 20 (66.7%)*
Prashad48 Phillips Respironics Encore Pro2 Tertiles of number of minutes used/night 1 month 14 7 (50%) 7 (50%)
Roberts49 Philips Respironics EncoreAnywhere Usage >4 h/night, 70% of nights 6 months 100 50 (50%) 50 (50%)
Simon50 APAP, CPAP, BPAP Device download Usage >4 h/night 6 months 49 19 (38.8%) 30 (61.2%)
Tovichien51 APAP, CPAP Device download Usage >4 h/night, 70% of nights 1 year 27 11 (40.7%) 16 (59.3%)

Note: *Indicating intermittent users.

Abbreviations: NA, not available; DME, durable medical equipment; APAP, automatic CPAP; BPAP, bi-level positive airway pressure machine; h, hours.

The adherence rate was assessed using data downloaded from CPAP devices either online or from the device in most studies, while CPAP adherence was defined by case notes, clinical data, parent report, or durable medical equipment (DME) providers as shown in Tables 2 and 4.24,42,43,46 The adherence criteria differed slightly among studies but was mostly defined as usage of four hours or more per night for 50–70% of nights. For the included studies without meta-analysis calculation (Tables 1 and 2), the adherence rate was 46.53% (9,883/21,240) from 13 studies based on usage of four hours or more per night (Table 2). The adherence rate for included studies for meta-analysis was 47.69% (237/497). In total, the adherence rate in children with OSA was 46.56% (10,120/21,737). The average CPAP usage in four studies (Table 2) ranged from 2.8 to 7.0 hours/night. Note that three studies compared clinical factors per specific group: developmental disabilities,25 family members with CPAP therapy,32 and age group.18 Additionally, one study compared those with CPAP adherence to intermittent users, who were categorized as non-adherent.47

Figure 4.

Figure 4

Calculation of ethnicity (Caucasian) of pediatric patients with obstructive sleep apnea on adherence of a continuous positive airway pressure machine.41–43,45

There were 11 calculations of factors predictive of CPAP adherence: age, sex, ethnicity, BMI, obesity, income, sleep efficiency, AHI, severity of OSA, residual AHI, and lowest oxygen saturation level (Figures 2-12). Three factors in regard to children who were adherent and those who were non-adherent with CPAP use were identified as age (Figure 2), BMI (Figure 5), and AHI (Figure 9). Children with OSA with effective adherence to CPAP use were younger and had lower BMIs than those with non-adherence. The mean differences (95% CI) of these two factors were −1.42 years (−2.07, −0.77) and −6.55 kg/m2 (−11.80, −1.30), respectively, as shown in Figures 2 and 5. Children with OSA with satisfactory adherence to CPAP had significantly higher AHIs than those who were non-adherent, with a mean difference of 4.75 events/hour (95% CI of 1.07, 8.43 events/hour) as shown in Figure 9. Regarding the quality of the included studies (Table 5), most had a score of satisfactory (8/10; 80%). Two studies were not evaluated due to non-cross-sectional study design.

Figure 2.

Figure 2

Calculation of age (years) of pediatric patients with obstructive sleep apnea on adherence of a continuous positive airway pressure machine.40–43,45,48,49,51

Figure 3.

Figure 3

Calculation of sex of pediatric patients with obstructive sleep apnea on adherence of a continuous positive airway pressure machine.40–49,51

Figure 5.

Figure 5

Calculation of body mass index (kg/m2) of pediatric patients with obstructive sleep apnea on adherence of a continuous positive airway pressure machine.40–42,45,49

Figure 6.

Figure 6

Calculation of obesity of pediatric patients with obstructive sleep apnea on adherence of a continuous positive airway pressure machine.40,46,48,51

Figure 7.

Figure 7

Calculation of income of family less than 20,000 USD of pediatric patients with obstructive sleep apnea on adherence of a continuous positive airway pressure machine.41,45

Figure 8.

Figure 8

Calculation of sleep efficiency (%) during polysomnography of pediatric patients with obstructive sleep apnea on adherence of a continuous positive airway pressure machine.41,49

Figure 9.

Figure 9

Calculation of apnea-hypopnea index (events/hour) of pediatric patients with obstructive sleep apnea on adherence of a continuous positive airway pressure machine.40,42,43,45,48–50

Figure 10.

Figure 10

Calculation of severe obstructive sleep apnea (OSA) of pediatric patients with OSA on adherence of a continuous positive airway pressure machine.43,45,46

Figure 11.

Figure 11

Calculation of residual apnea-hypopnea index (events/hour) of pediatric patients with obstructive sleep apnea on adherence of a continuous positive airway pressure machine.40,43

Figure 12.

Figure 12

Calculation of lowest oxygen level (%) during polysomnography of pediatric patients with obstructive sleep apnea on adherence of a continuous positive airway pressure machine.43,48,49

Table 5.

Study Quality Evaluation by the Newcastle-Ottawa Scale Adapted for Cross-Sectional Studies of the Included Studies of Pediatric Studies with Obstructive Sleep Apnea on Compliance of a Continuous Positive Airway Pressure Machine: Included Studies for a Meta-Analysis

Study Year Study Design Selection Process (4) Comparability (2) Outcome Measures (3) Total (9) Interpretation
Alebraheem 2018 Qualitative - - - - NA
Avis 2019 Prospective 3 0 3 6 Satisfactory
Beebe 2011 Prospective 2 1 1 4 Satisfactory
Hawkins 2016 Retrospective 3 0 3 6 Satisfactory
Katz 2020 Prospective 1 0 3 4 Satisfactory
Lynch 2019 Prospective 3 0 3 6 Satisfactory
Nathan 2013 Retrospective 4 0 3 7 Good
Nixon 2011 Retrospective 3 0 3 6 Satisfactory
Prashad 2013 Qualitative - - - - NA
Roberts 2016 Retrospective cohort 3 0 3 6 Satisfactory
Simon 2012 Cross-sectional 1 0 2 3 Unsatisfactory
Tovichien 2022 Prospective 3 0 3 6 Satisfactory

Note: NA, not available due to qualitative study design.

Discussion

This meta-analysis showed that the adherence rate in children with OSA was 46.56% with CPAP usage of four hours or more based on 21,737 children with OSA. Age, BMI, and AHI were related to adequate CPAP adherence.

Compared with the previous meta-analysis, we summarized the adherence rate based on a large study population. Meta-analysis calculations were added for 11 factors, and we added 11 articles published after 2019 that were not included in the previous systematic review.12 After including more studies in the present meta-analysis, we found significant results in regard to age, BMI, and AHI on CPAP adherence in children with OSA (Figures 2, 5 and 9) and nearly significant results regarding sex with a 95% CI of 0.46, 1.00 (Figure 3). The previous meta-analysis was unable to declare significance in regard to age (not performed), BMI (difference −0.14; 95% CI: −0.47, 0.19), or AHI (difference 4.32; 95% CI: −0.61, 9.26).12 As previously noted, these three factors were significant predictors of CPAP adherence in this study. These differences between the two meta-analysis studies may be due to more studies included in the present analysis. However, we did not perform an analysis on CPAP vs BPAP, as in the previous meta-analysis, as we were unable to find appropriate data for calculation in the two studies.26,35 In our study, one study reported significant adherence between CPAP vs BPAP with an unadjusted odds ratio of 3.60 (2.39–5.10).46 However, this was not significant after being adjusted for other factors. Additionally, we were unable to analyze the developmental delay factor as data were not sufficient for the calculation. Only the study by Kang et al reported findings in regard to developmental delay, while the Hawkins study had incomplete data on this factor, resulting in the inability to calculate as a meta-analysis.25,43 Finally, this present study included only published articles, unlike the previous report, which included abstract articles.12

As previously reported, children with OSA who were younger were adherent with CPAP. The adherent group was −1.85 years younger than the non-adherent group. The younger patients may have had caregivers, usually their mother, who facilitated their CPAP treatment. By contrast, older children may have more barriers to wearing the CPAP device during sleep. A study conducted with adolescent patients with an average age of 13.2 years found that older children may have several barriers to CPAP use because they are away from home more often (47%); they may simply want to forget about having OSA (43.1%); they may not feel well (42.0%); or they may forget to use the device (39.2%).50 In addition, a lack of help from a parent or other caregiver to use CPAP at night represented another barrier in 31.4%.50

Similar to age, BMI was negatively correlated with CPAP adherence (Figure 5). In other words, those with lower BMI had better CPAP adherence than those with higher BMI. As shown in Figure 5, the significance of BMI was driven by the study by Lynch et al.45 A previous report found that high BMI was related to mask leakage (r = 0.579; p < 0.001) resulting in poor CPAP adherence.52 Obese children may have a higher risk for mask leakage, leading to poor adherence as high mask leakage was correlated with poor adherence (r = −0.376; p = 0.008).52

Regarding polysomnographic factors, only AHI was related to CPAP adherence in children with OSA. Previous studies in adult patients with OSA found that lowest oxygen saturation differed significantly between the adherence group and the non-adherence group (80.33% vs 85.18%; p value = 0.017) as well as duration of oxygen saturation lower than 90% (10.0% vs 5.0%; p = 0.013).53,54 Four studies showed that AHI was related to CPAP adherence in adult patients.53–56 Adult patients with oxygen desaturation index (ODI), an index comparable to AHI, of over 60 times/hour had a CPAP adherence rate of 90.8% at 10 years. The ODI or AHI also had an adjusted hazard ratio for CPAP adherence of 0.97 (p < 0.001). As previously reported,57 severity of OSA may be associated with more sleepiness, leading to better adherence to CPAP but not other polysomnographic factors such as oxygen level or sleep efficiency (Figures 11 and 12).

Above, we have discussed why AHI was associated with CPAP adherence in adults. In children, our analysis found that six of seven studies in the meta-analysis calculation had non-significant higher AHI in the adherent group than the non-adherent group; the study by Alebraheem et al was the exception (Figure 9). Additionally, another study identified non-significant higher AHI in the adherent group as well (20.5 vs 17.5 events/h; p 0.651).51 Note that the study by Tovichien et al was not included as they reported median AHI. After totaling up, the adherent group had greater significant value than the non-adherent group. Unlike in adults, further studies may be required to explain why AHI is significantly related to CPAP adherence. One study found that less severe OSA was related to low adherence to CPAP with a relative risk of 0.97.19

This study also added data about the adherence rate in children with OSA in a large sample (n = 22,075), which was not reported in the previous meta-analysis. The adherence rate was almost 50% but may be higher in specific populations, eg, 90% in children with developmental delays,25,43 87% in children with obesity or craniofacial anomalies,28 or in those using BPAP (91–100%).27,46 This adherence rate was slightly lower than that previously reported at 56.9%.11 These differences may be due to sample size numbers and included studies. The previous study had 1,079 participants from 20 studies, while this study had 22,075 participants from 34 studies.11 Several studies conducted with adults found that CPAP adherence rate ranged from 34% to 83%.58–62 Similar to children with OSA, there are several predictors of good adherence, such as age, sex, education level, and AHI.61–65

This study has several limitations. First, there are no standard criteria for CPAP adherence in children with OSA, resulting in different adherence criteria (Table 2). Second, some factors are not analyzed as they do not meet the calculation criteria for meta-analysis and data are not available for some populations, for example, Black children or children with asthma.18 Finally, interventions to facilitate CPAP adherence or OSA consequences or related conditions such as quality of life or cardiovascular diseases were not studied.66–72

Conclusions

Young age, low BMI, and high AHI are associated with satisfactory CPAP adherence in children with OSA. Although these factors were significant, the overall quality of evidence was fair, and the duration of study was generally about six months with no interventions. Further studies with longer durations or interventions should be considered. However, these factors may be helpful for clinicians in order to initiate CPAP therapy in potential patients for satisfactory adherence. Additionally, further interventions may be important for these groups of patients to facilitate CPAP adherence. Based on the large sample size, the CPAP adherence rate for children with OSA was 46.56%.

Funding Statement

This study was granted by Faculty of Medicine, Khon Kaen University, Thailand (Grant Number SY66001).

Patient and Public Involvement

Patients and/or the public were not involved in the design, or conduct, or reporting, or dissemination plans of this research.

Author Contributions

All authors made a significant contribution to the work reported, whether that is in the conception, study design, execution, acquisition of data, analysis and interpretation, or in all these areas; took part in drafting, revising or critically reviewing the article; gave final approval of the version to be published; have agreed on the journal to which the article has been submitted; and agree to be accountable for all aspects of the work.

Disclosure

The authors declare no potential conflicts of interest with respect to the research, authorship, and/or publication of this article.

References

  • 1.Lumeng JC, Chervin RD. Epidemiology of pediatric obstructive sleep apnea. Proc Am Thorac Soc. 2008;5:242–252. doi: 10.1513/pats.200708-135MG [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 2.Xu Z, Wu Y, Tai J, et al. Risk factors of obstructive sleep apnea syndrome in children. J Otolaryngol Head Neck Surg. 2020;49:11. doi: 10.1186/s40463-020-0404-1 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 3.Simpson R, Oyekan AA, Ehsan Z, et al. Obstructive sleep apnea in patients with Down syndrome: current perspectives. Nat Sci Sleep. 2018;10:287–293. doi: 10.2147/NSS.S154723 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 4.Trivedi M, ElMallah M, Bailey E, et al. Pediatric Obstructive Sleep Apnea and Asthma: clinical Implications. Pediatr Ann. 2017;46(9):e332–e335. doi: 10.3928/19382359-20170815-03 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 5.Cao Y, Wu S, Zhang L, et al. Association of allergic rhinitis with obstructive sleep apnea: a meta-analysis. Medicine. 2018;97(51):e13783. doi: 10.1097/MD.0000000000013783 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 6.Andersen IG, Homøe P. Obstructive sleep apnea in children and adolescents with and without obesity. Eur Arch Otorhinolaryngol. 2019;276:871–878. doi: 10.1007/s00405-019-05290-2 [DOI] [PubMed] [Google Scholar]
  • 7.Krysta K, Bratek A, Zawada K, et al. Cognitive deficits in adults with obstructive sleep apnea compared to children and adolescents. J Neural Transm. 2017;124:187–201. doi: 10.1007/s00702-015-1501-6 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 8.Cuspidi C, Tadic M, Gherbesi E, et al. Targeting subclinical organ damage in obstructive sleep apnea: a narrative review. J Hum Hypertens. 2021;35(1):26–36. doi: 10.1038/s41371-020-00397-0 [DOI] [PubMed] [Google Scholar]
  • 9.Marcus CL, Brooks LJ, Draper KA, et al. Diagnosis and management of childhood obstructive sleep apnea syndrome. Pediatrics. 2012;130:576–584. doi: 10.1542/peds.2012-1671 [DOI] [PubMed] [Google Scholar]
  • 10.Sudarsan SS, Paramasivan VK, Arumugam SV, et al. Comparison of treatment modalities in syndromic children with obstructive sleep apnea--A randomized cohort study. Int J Pediatr Otorhinolaryngol. 2014;78(9):1526–1533. doi: 10.1016/j.ijporl.2014.06.027 [DOI] [PubMed] [Google Scholar]
  • 11.Watach AJ, Xanthopoulos MS, Afolabi-Brown O, et al. Positive airway pressure adherence in pediatric obstructive sleep apnea: a systematic scoping review. Sleep Med Rev. 2020;51:101273. doi: 10.1016/j.smrv.2020.101273 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 12.Blinder H, Momoli F, Bokhaut J, et al. Predictors of adherence to positive airway pressure therapy in children: a systematic review and meta-analysis. Sleep Med. 2020;69:19–33. doi: 10.1016/j.sleep.2019.12.015 [DOI] [PubMed] [Google Scholar]
  • 13.Ennis J, Rohde K, Chaput J-P, et al. Facilitators and Barriers to Noninvasive Ventilation Adherence in Youth with Nocturnal Hypoventilation Secondary to Obesity or Neuromuscular Disease. J Clin Sleep Med. 2015;11(12):1409–1416. doi: 10.5664/jcsm.5276 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 14.Marcus CL, Rosen G, Ward SLD, et al. Adherence to and effectiveness of positive airway pressure therapy in children with obstructive sleep apnea. Pediatrics. 2006;117:e442–451. doi: 10.1542/peds.2005-1634 [DOI] [PubMed] [Google Scholar]
  • 15.Killick R, Marshall NS. The impact of device modifications and pressure delivery on adherence. Sleep Med Clin. 2021;16:75–84. doi: 10.1016/j.jsmc.2020.10.008 [DOI] [PubMed] [Google Scholar]
  • 16.Sisay M, Mengistu G, Edessa D. Epidemiology of self-medication in Ethiopia: a systematic review and meta-analysis of observational studies. BMC Pharmacol Toxicol. 2018;19:56. doi: 10.1186/s40360-018-0248-8 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 17.Namwaing P, Ngamjarus C, Sakaew W, et al. Chest physical therapy and outcomes in primary spontaneous pneumothorax: a systematic review. J Med Assoc Thailand. 2021;104:S165–S168. [Google Scholar]
  • 18.Bhattacharjee R, Benjafield AV, Armitstead J, et al. Adherence in children using positive airway pressure therapy: a big-data analysis. Lancet Digit Health. 2020;2:e94–e101. doi: 10.1016/S2589-7500(19)30214-6 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 19.Blinder H, Momoli F, Holland SH, et al. Clinical predictors of nonadherence to positive airway pressure therapy in children: a retrospective cohort study. J Clin Sleep Med. 2021;17(6):1183–1192. doi: 10.5664/jcsm.9162 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 20.Cielo CM, Hernandez P, Ciampaglia AM, et al. Positive airway pressure for the treatment of OSA in infants. Chest. 2021;159(2):810–817. doi: 10.1016/j.chest.2020.08.020 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 21.Castorena-Maldonado A, Torre-Bouscoulet L, Meza-Vargas S, et al. Preoperative continuous positive airway pressure compliance in children with obstructive sleep apnea syndrome: assessed by a simplified approach. Int J Pediatr Otorhinolaryngol. 2008;72(12):1795–1800. doi: 10.1016/j.ijporl.2008.08.016 [DOI] [PubMed] [Google Scholar]
  • 22.Com G, Carroll JL, Tang X, et al. Characteristics and surgical and clinical outcomes of severely obese children with obstructive sleep apnea. J Clin Sleep Med. 2015;11(04):467–474. doi: 10.5664/jcsm.4608 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 23.DiFeo N, Meltzer LJ, Beck SE, et al. Predictors of positive airway pressure therapy adherence in children: a prospective study. J Clin Sleep Med. 2012;8(03):279–286. doi: 10.5664/jcsm.1914 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 24.Elder D, Gandhi S, Campbell A. CPAP for paediatric patients in Aotearoa New Zealand: audit of a developing service at Capital and Coast DHB 2005-2020. N Z Med J. 2022;135:62–71. [PubMed] [Google Scholar]
  • 25.Kang EK, Xanthopoulos MS, Kim JY, et al. Adherence to positive airway pressure for the treatment of obstructive sleep apnea in children with developmental disabilities. J Clin Sleep Med. 2019;15:915–921. doi: 10.5664/jcsm.7850 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 26.Katz SL, MacLean JE, Hoey L, et al. Insulin resistance and hypertension in obese youth with sleep-disordered breathing treated with positive airway pressure: a prospective multicenter study. J Clin Sleep Med. 2017;13:1039–1047. doi: 10.5664/jcsm.6718 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 27.Machaalani R, Evans CA, Waters KA. Objective adherence to positive airway pressure therapy in an Australian paediatric cohort. Sleep Breath. 2016;20:1327–1336. doi: 10.1007/s11325-016-1400-6 [DOI] [PubMed] [Google Scholar]
  • 28.Marcus CL, Ward SL, Mallory GB, et al. Use of nasal continuous positive airway pressure as treatment of childhood obstructive sleep apnea. J Pediatr. 1995;127:88–94. doi: 10.1016/S0022-3476(95)70262-8 [DOI] [PubMed] [Google Scholar]
  • 29.Mulholland A, Mihai R, Ellis K, et al. Paediatric CPAP in the digital age. Sleep Med. 2021;84:352–355. doi: 10.1016/j.sleep.2021.06.006 [DOI] [PubMed] [Google Scholar]
  • 30.O’Donnell AR, Bjornson CL, Bohn SG, et al. Compliance rates in children using noninvasive continuous positive airway pressure. Sleep. 2006;29:651–658. [PubMed] [Google Scholar]
  • 31.Perriol M-P, Jullian-Desayes I, Joyeux-Faure M, et al. Long-term adherence to ambulatory initiated continuous positive airway pressure in non-syndromic OSA children. Sleep Breath. 2019;23:575–578. doi: 10.1007/s11325-018-01775-2 [DOI] [PubMed] [Google Scholar]
  • 32.Puri P, Ross KR, Mehra R, et al. Pediatric positive airway pressure adherence in obstructive sleep apnea enhanced by family member positive airway pressure usage. J Clin Sleep Med. 2016;12:959–963. doi: 10.5664/jcsm.5924 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 33.Ramirez A, Khirani S, Aloui S, et al. Continuous positive airway pressure and noninvasive ventilation adherence in children. Sleep Med. 2013;14:1290–1294. doi: 10.1016/j.sleep.2013.06.020 [DOI] [PubMed] [Google Scholar]
  • 34.Trucco F, Chatwin M, Semple T, et al. Sleep disordered breathing and ventilatory support in children with Down syndrome. Pediatr Pulmonol. 2018;53(10):1414–1421. doi: 10.1002/ppul.24122 [DOI] [PubMed] [Google Scholar]
  • 35.Uong EC, Epperson M, Bathon SA, et al. Adherence to nasal positive airway pressure therapy among school-aged children and adolescents with obstructive sleep apnea syndrome. Pediatrics. 2007;120:e1203–1211. doi: 10.1542/peds.2006-2731 [DOI] [PubMed] [Google Scholar]
  • 36.van den Broek N, Broer L, Vandenbussche N, et al. Obstructive sleep apnea in people with intellectual disabilities: adherence to and effect of CPAP. Sleep Breath. 2021;25:1257–1265. doi: 10.1007/s11325-020-02221-y [DOI] [PubMed] [Google Scholar]
  • 37.Weiss MR, Allen ML, Landeo-Gutierrez JS, et al. Defining the patterns of PAP adherence in pediatric obstructive sleep apnea: a clustering analysis using real-world data. J Clin Sleep Med. 2021;17:1005–1013. doi: 10.5664/jcsm.9100 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 38.Willis LD, Spray BJ, Scribner A, et al. Outcomes of pediatric titration sleep studies following empirical use of positive airway pressure and the effect on adherence to therapy. Respir Care. 2022;67(4):464–470. doi: 10.4187/respcare.09521 [DOI] [PubMed] [Google Scholar]
  • 39.Xanthopoulos MS, Kim JY, Blechner M, et al. Self-efficacy and short-term adherence to continuous positive airway pressure treatment in children. Sleep. 2017. doi: 10.1093/sleep/zsx096 [DOI] [PubMed] [Google Scholar]
  • 40.Alebraheem Z, Toulany A, Baker A, et al. Facilitators and barriers to positive airway pressure adherence for adolescents. A qualitative study. Ann Am Thorac Soc. 2018;15(1):83–88. doi: 10.1513/AnnalsATS.201706-472OC [DOI] [PubMed] [Google Scholar]
  • 41.Avis KT, Gamble KL, Schwebel DC. Effect of positive airway pressure therapy in children with obstructive sleep apnea syndrome: does positive airway pressure use reduce pedestrian injury risk? Sleep Health. 2019;5:161–165. doi: 10.1016/j.sleh.2018.12.006 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 42.Beebe DW, Byars KC. Adolescents with obstructive sleep apnea adhere poorly to positive airway pressure (PAP), but PAP users show improved attention and school performance. PLoS One. 2011;6:e16924. doi: 10.1371/journal.pone.0016924 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 43.Hawkins SMM, Jensen EL, Simon SL, et al. Correlates of pediatric CPAP adherence. J Clin Sleep Med. 2016;12:879–884. doi: 10.5664/jcsm.5892 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 44.Katz SL, Kirk VG, MacLean JE, et al. Factors related to positive airway pressure therapy adherence in children with obesity and sleep-disordered breathing. J Clin Sleep Med. 2020;16:733–741. doi: 10.5664/jcsm.8336 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 45.Lynch MK, Elliott LC, Avis KT, et al. Quality of life in youth with Obstructive Sleep Apnea Syndrome (OSAS) treated with Continuous Positive Airway Pressure (CPAP) Therapy. Behav Sleep Med. 2019;17:238–245. doi: 10.1080/15402002.2017.1326918 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 46.Nathan AM, Tang JPL, Goh A, et al. Compliance with noninvasive home ventilation in children with obstructive sleep apnoea. Singapore Med J. 2013;54(12):678–682. doi: 10.11622/smedj.2013241 [DOI] [PubMed] [Google Scholar]
  • 47.Nixon GM, Mihai R, Verginis N, et al. Patterns of continuous positive airway pressure adherence during the first 3 months of treatment in children. J Pediatr. 2011;159(5):802–807. doi: 10.1016/j.jpeds.2011.04.013 [DOI] [PubMed] [Google Scholar]
  • 48.Prashad PS, Marcus CL, Maggs J, et al. Investigating reasons for CPAP adherence in adolescents: a qualitative approach. J Clin Sleep Med. 2013;9:1303–1313. doi: 10.5664/jcsm.3276 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 49.Roberts SD, Kapadia H, Greenlee G, et al. Midfacial and dental changes associated with nasal positive airway pressure in children with obstructive sleep apnea and craniofacial conditions. J Clin Sleep Med. 2016;12(04):469–475. doi: 10.5664/jcsm.5668 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 50.Simon SL, Duncan CL, Janicke DM, et al. Barriers to treatment of paediatric obstructive sleep apnoea: development of the adherence barriers to continuous positive airway pressure (CPAP) questionnaire. Sleep Med. 2012;13(2):172–177. doi: 10.1016/j.sleep.2011.10.026 [DOI] [PubMed] [Google Scholar]
  • 51.Tovichien P, Kulbun A, Udomittipong K. Comparing adherence of Continuous and Automatic Positive Airway Pressure (CPAP and APAP) in Obstructive Sleep Apnea (OSA) children. Front Pediatr. 2022;10:841705. doi: 10.3389/fped.2022.841705 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 52.Sopkova Z, Dorkova Z, Tkacova R. Predictors of compliance with continuous positive airway pressure treatment in patients with obstructive sleep apnea and metabolic syndrome. Wien Klin Wochenschr. 2009;121:398–404. doi: 10.1007/s00508-009-1181-z [DOI] [PubMed] [Google Scholar]
  • 53.Riachy M, Najem S, Iskandar M, et al. Factors predicting CPAP adherence in obstructive sleep apnea syndrome. Sleep Breath. 2017;21(2):295–302. doi: 10.1007/s11325-016-1408-y [DOI] [PubMed] [Google Scholar]
  • 54.Campos-Rodriguez F, Martinez-Alonso M, Sanchez-de-la-Torre M, et al. Long-term adherence to continuous positive airway pressure therapy in non-sleepy sleep apnea patients. Sleep Med. 2016;17:1–6. doi: 10.1016/j.sleep.2015.07.038 [DOI] [PubMed] [Google Scholar]
  • 55.Kohler M, Smith D, Tippett V, et al. Predictors of long-term compliance with continuous positive airway pressure. Thorax. 2010;65:829–832. doi: 10.1136/thx.2010.135848 [DOI] [PubMed] [Google Scholar]
  • 56.Baratta F, Pastori D, Bucci T, et al. Long-term prediction of adherence to continuous positive air pressure therapy for the treatment of moderate/severe obstructive sleep apnea syndrome. Sleep Med. 2018;43:66–70. doi: 10.1016/j.sleep.2017.09.032 [DOI] [PubMed] [Google Scholar]
  • 57.McArdle N, Devereux G, Heidarnejad H, et al. Long-term use of CPAP therapy for sleep apnea/hypopnea syndrome. Am J Respir Crit Care Med. 1999;159:1108–1114. doi: 10.1164/ajrccm.159.4.9807111 [DOI] [PubMed] [Google Scholar]
  • 58.Weaver TE, Grunstein RR. Adherence to continuous positive airway pressure therapy: the challenge to effective treatment. Proc Am Thorac Soc. 2008;5:173–178. doi: 10.1513/pats.200708-119MG [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 59.Sarrell EM, Chomsky O, Shechter D. Treatment compliance with continuous positive airway pressure device among adults with obstructive sleep apnea (OSA): how many adhere to treatment?. Harefuah. 2013;152:140–144, 184, 183. [PubMed] [Google Scholar]
  • 60.Campos-Rodriguez F, Martinez-Alonso M, Sanchez-de-la-Torre M, et al. Long-term adherence to continuous positive airway pressure therapy in non-sleepy sleep apnea patients. Sleep Med. 2016;17:1–6. [DOI] [PubMed] [Google Scholar]
  • 61.Kaewkes C, Sawanyawisuth K, Sawunyavisuth B. Are symptoms of obstructive sleep apnoea related to good continuous positive airway pressure compliance? ERJ Open Res. 2020;6:1–4. doi: 10.1183/23120541.00169-2019 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 62.Sawunyavisuth B. What personal experiences of CPAP use affect CPAP adherence and duration of CPAP use in OSA patients? J Med Assoc Thailand. 2018;101:S245–S249. [Google Scholar]
  • 63.Campos-Rodriguez F, Martinez-Garcia MA, Reyes-Nuñez N, et al. Long-term continuous positive airway pressure compliance in females with obstructive sleep apnoea. Eur Respir J. 2013;42:1255–1262. doi: 10.1183/09031936.00165812 [DOI] [PubMed] [Google Scholar]
  • 64.Russo-Magno P, O’Brien A, Panciera T, et al. Compliance with CPAP therapy in older men with obstructive sleep apnea. J Am Geriatr Soc. 2001;49(9):1205–1211. doi: 10.1046/j.1532-5415.2001.49238.x [DOI] [PubMed] [Google Scholar]
  • 65.Şahin E, Cengiz C, Dağıstan H, et al. Factors affecting CPAP compliance in patients with obstructive sleep apnea. J Surg Med. 2021;5:340–343. doi: 10.28982/josam.897532 [DOI] [Google Scholar]
  • 66.Sawunyavisuth B. What are predictors for a continuous positive airway pressure machine purchasing in obstructive sleep apnea patients? Asia Pacific J Sci Technol. 2018;23:5. [Google Scholar]
  • 67.Boonwang T, Namwaing P, Srisaphonphusitti L, et al. Esports may improve cognitive skills in soccer players: a systematic review. Asia Pacific J Sci Technol. 2022;27:64. [Google Scholar]
  • 68.Sawunyavisuth B, Ngamjarus C, Sawanyawisuth K. Any effective intervention to improve CPAP adherence in children with obstructive sleep apnea: a systematic review. Glob Pediatr Health. 2021;8:2333794X211019884. doi: 10.1177/2333794X211019884 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 69.Sanlung T, Sawanyawisuth K, Silaruks S, et al. Clinical characteristics and complications of obstructive sleep apnea in srinagarind hospital. J Med Assoc Thailand. 2020;103:36–39. [Google Scholar]
  • 70.Sawunyavisuth B, Ngamjarus C, Sawanyawisuth K. A meta-analysis to identify factors associated with CPAP machine purchasing in patients with obstructive sleep apnea. Biomed Rep. 2022;16:45. doi: 10.3892/br.2022.1528 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 71.Manasirisuk P, Chainirun N, Tiamkao S, et al. Efficacy of generic atorvastatin in a real-world setting. Clin Pharmacol. 2021;13:45–51. doi: 10.2147/CPAA.S285750 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 72.Soontornrungsun B, Khamsai S, Sawunyavisuth B, et al. Obstructive sleep apnea in patients with diabetes less than 40 years of age. Diabetes Metab Syndrome. 2020;14:1859–1863. doi: 10.1016/j.dsx.2020.09.008 [DOI] [PubMed] [Google Scholar]

Articles from Therapeutics and Clinical Risk Management are provided here courtesy of Dove Press

RESOURCES