Abstract
Background
During the intrusion of lower incisors with clear aligners (CAs), root disengagement from the alveolar bone often occurs, resulting in serious complications. This study aimed to determine the potential force mechanism of the mandibular anterior teeth under the pressure of CA, providing theoretical data for clinical practice.
Methods
In this study, a 3D finite element model was established, including the CA, periodontal ligament, and mandibular dentition. Incisor mandibular plane angles were set as 5 groups: 90°, 95°, 100°, 105°, and 110°. The 4 mandibular incisors were intruded by 0.2 mm, while the canines were the anchorage teeth. The stress, force systems, and potential movement trends of mandibular anterior teeth were obtained.
Results
The compressive stress of the incisors was concentrated in the lingual fossa, incisal ridge, and apex. With the increase in IMPA, the moment of central incisors changed from lingual crown moment to labial crown moment, with the turning point between 100° and 105°, but the center of resistance (CR) was always subjected to the force toward the lingual and intrusive direction. The force and moment toward the labial side of the lateral incisors were greater than those toward the central incisors. The canines always tipped distally and received extrusive force with no relationship with IMPA.
Conclusions
With the increase in the initial IMPA, the direction of labiolingual force on the mandibular incisors was reversed. However, the root of the lower incisors always tipped labially, which indicated fenestration and dehiscence.
Background
Class II malocclusion is accompanied by symptoms such as convexity, mandibular retraction, deep overbite, and deep overjet, which lead to an imbalance of facial esthetics and adversely affect physical and mental health. In clinical practice, it is necessary to prioritize leveling the curve of Spee (COS). The normal COS creates conditions for the retraction of maxillary anterior teeth, thus reconstructing facial esthetics. The level of COS directly affects the automatic rotation of the mandible and the change in the esthetic ratio. Therefore, the intrusion of mandibular incisors is the key step for the treatment of Class II malocclusion.
For different classifications and severities of Class II malocclusion, IMPA also varies. The goal of the first stage of treatment is to open the occlusion and level the COS. Currently, clear aligner technology is widely used in clinical practice. Compared with fixed appliances, CAs are more esthetic and comfortable [1]. However, during the intrusion of the lower incisors, CA is not effective enough, when accompanied by labial alveolar bone damage (Fig. 1). Kravitz et al. [2] reported that the accuracy of the CA in the intrusion of the mandibular central and lateral incisors was 44% and 45%, respectively. The study of Al-Balaa et al. [3] suggested that the accuracy of intrusion was 44.71% in lower incisors.
Many researchers [4–8] have performed biomechanical studies on CA by three-dimensional (3D) FE analysis. In previous studies, the mandibular incisors in the models were all upright. To explore the actual efficiency of the invisible appliance on lower anterior teeth, Ni et al. [4] established a 3D FE model by scanning the normal occlusion mandible with cone-beam computed tomography (CBCT). In the studies of Cortona et al., Yokoi et al., and Gabriele et al. [6–8], instead of real mechanical parameters and geometry, the CA was set as a homogeneous solid body, expanding uniformly along the outer surface of the crown. Previous studies have not explained the common risk of fenestration and dehiscence in the intrusion of mandibular incisors. Therefore, it is necessary to further explore the force mechanism of intrusion with CA in Class II malocclusion.
According to the compensation characteristics of the mandibular incisors in Class II malocclusion, this study intended to establish 3D FE models including different initial IMPA incisors, in which the incisors are 2 mm above the occlusal plane. By analyzing models, the potential force mechanism of mandibular incisor intrusion can be obtained to guide the safe application of CA in clinical practice.
Materials and methods
Establishment of the 3D FE model
A standard mandibular model (i21D-400C, Nissin Dental Products Inc., Tokyo, Japan) was scanned by industrial CT (METROTOM 1500, Carl Zeiss AG, Oberkochen, Germany) with a slice of 0.1 mm. The obtained images were imported into Mimics 17.0 (Materialise NV, Leuven, Belgium) for 3D reconstruction. HyperMesh 14.0 (Altair Engineering Inc., Troy, USA) was used to further process and finally obtain the 3D FE model of the mandibular dentition. The PDL was set to extend uniformly on the root by 0.3 mm [9]. Based on Masterforce (Angelalign Technology Inc., Shanghai, China), the thermoforming process of CA was simulated to obtain authentic nonuniform thickness data.
A world coordinate system in engineering was applied in the research. The X-axis is the mesiodistal axis (the mesial direction is positive, and the distal direction is negative). The Y-axis is the labiolingual axis (the labial direction is positive and the lingual is negative). The Z-axis is the vertical axis (intrusion is positive and extrusion is negative).
Five groups of FE models were established by the above method. The depth of COS was 3.0 mm. The initial IMPA of the mandibular incisors were 90° (25° in the world coordinate system), 95° (30° in the world coordinate system), 100° (35° in the world coordinate system), 105° (40° in the world coordinate system), and 110° (45° in the world coordinate system).
The teeth were divided into tetrahedral elements [10], the PDLs into hexahedral elements, and the aligners into quadrilateral shell elements with true thickness information. The number of elements for the dentition, PDL, and the aligner was identically applied as 96, 168, 308, 219, and 6530, respectively.
Material properties and boundary conditions
The teeth were set as a continuous, homogeneous, and uniform linear elastic material with an elastic modulus of 20,600. CA is a linear elastic material with a nonuniform thickness. The material properties of MC-S widely used in the clinic were adopted for CA. The PDL was set as a viscoelastic material [11] (Table 1).
Table 1.
Young’s modulus (MPa) | Poisson’s ratio | |
---|---|---|
Tooth | 20,600 | 0.30 |
PDL | 0.689 | 0.49 |
Aligner | 1000 | 0.40 |
The root and the PDL were joined by bonded contact, that is, they shared nodes and did not move relatively [12]. The crown and the CA were constrained by frictional contact, and the frictional coefficient was 0.3.
Intrusion design and outcomes
For five FE models with a COS depth of 3.0 mm and initial IMPA of 90°, 95°, 100°, 105°, and 110°, the mandibular incisors were simultaneously intruded by 0.2 mm. According to the common clinical design, rectangular attachments were set on the labial surface on canines (Fig. 2). Referring to the Tweed analysis, when the IMPA is 90°, it is a well-balanced face [13]. Therefore, the intrusion direction was consistent in the five groups of models, that was, along the long axis of the incisor when the IMPA was 90°. The stress of teeth and PDLs, the moment, the force of the CR, and the potential movement trend of lower anterior teeth were obtained.
The von Mises stress, minimum principal stress, and maximum principal stress were calculated. von Mises stress reflects the overall stress concentration without direction. The maximum principal stress reflects the tensile stress, and the minimum principal stress reflects the compressive stress.
Results
The force patterns of the bilateral identical teeth were basically symmetrical (Fig. 3). Therefore, in the subsequent analyses, the mandibular left incisors and canine will be used to represent the stress distribution and potential movement trend of the bilateral identical teeth. In the study, the force of the CR was used to represent the resultant force on the tooth (including the crown and root). Since both incisors and canines are single-rooted teeth, the CR was 2/5 away from the alveolar ridge and 3/5 away from the root apex [14].
Force systems and stress of incisors
When the initial IMPA of the central incisor was 90°, lingual crown moment was applied during the intrusion with CA. With the increase in the initial IMPA, the lingual crown moment decreased and gradually transformed into the labial crown moment. When the initial IMPA reached 105°, the central incisor was subjected to labial crown moment. The CR was always subjected to the force toward the lingual and intrusive directions with the increase in the initial IMPA, and the magnitude of the intrusive force did not change significantly (Fig. 4).
The force system of lateral incisors was similar to that of central incisors, but the labial crown moment and intrusive force were always greater than those of central incisors. When the initial IMPA was less than or equal to 95°, the lateral incisor was subjected to lingual crown moment, and the CR received a resultant force toward the lingual side and a force in the vertical intrusive direction. When the initial IMPA reached 100°, the direction of labiolingual force and vertical force remained unchanged, but the moment changed to the labial crown moment. When the initial IMPA was greater than or equal to 105°, the moment changed to the labial crown moment, and the CR was subjected to the force toward the labial direction (Fig. 4). The results revealed that CA produced the intrusive force of mandibular incisors through structural deformation. The deformation of the CA structure mainly occurred in the relative change of the incisal ridge and the gingival margin. In addition to intrusive forces, CA structural deformation also generated unwanted forces that may cause unwanted potential movement trends of the lower incisors during treatment.
The von Mises stress of the incisors was mainly concentrated in the lingual fossa and incisal ridges, which were also the main contact areas with the CA. When the initial IMPA was 90° and 95°, the compressive stress on the root of the central incisor was concentrated on the apex and lingual surface. With the IMPA increased, the compressive stress concentration area changed to labial surface gradually. When the initial IMPA increased to 100°, the compressive stress area of the root was only concentrated on the root apex. When the initial IMPA was 110°, the compressive stress covered all labial areas of the root, from the apex to the root cervix. The minimum principal stress distribution of the PDLs was similar to that of the roots (Fig. 5). The stress distribution of lateral incisors was similar to that of central incisors, but von Mises stress and PDL compressive stress were larger than those of central incisors (Fig. 6).
Force systems and stress of canines
The mandibular canines were always subjected to distal crown moment, and the CR received the force toward the mesial direction and the vertical extrusive force. With the increase in the initial IMPA of the incisors, the distal crown moment decreased slightly, and the mesiodistal and vertical force direction and value did not change significantly (Fig. 7).
The force system of the canine had no significant relationship with the change in the initial IMPA (Fig. 7), as did the stress distribution. The von Mises stress of the canines was concentrated around the cusps, distal labial inclined planes, and attachments. The maximum principal stress indicated that tensile stress was widely distributed in the cervical 1/2 of the root. The tensile stress on the labial and lingual surfaces of the root was basically symmetrical, while that on the distal surface was greater than that on the mesial surface. In PDL, the tensile stress on the mesial, labial, and distal surfaces was similar to the distribution of the root. However, on the lingual surface of the PDL, tensile stress was concentrated in the apical 1/2 of the PDL (Fig. 8). The forces generated by the CA deformation not only intruded the lower incisors but also acted on the lower canines as anchorages. This deformation force included the force toward the mesial and extrusive direction of the lower canine, while the apex tended to move labially.
Movement trends
For both central and lateral incisors, when the initial IMPA was less than or equal to 95°, their apex tended to rotate to the labial side and the crown to the lingual side, while the apex moved labially. When the initial IMPA reached 100°, the potential movement direction of the central incisor remained unchanged. For the lateral incisor, when the initial IMPA reached 100°, the crown tended to rotate to the labial side, the apex to the lingual side, and the root cervix moved labially. When the initial IMPA was 105°, both the crown of the central and lateral incisors rotated labially, and the root cervix tended to move labially. The results suggested that during the intrusion, although the initial IMPA was different, the tooth root (either root apex or root cervix) always had a tendency to move to the labial side through rotation. With the increase in IMPA, the rotation direction of the teeth reversed, with direction turning points between 100° and 105° in the central incisors and between 95° and 100° in the lateral incisors. Compared with the central incisors, the lateral incisors had a greater trend of labial movement of the crown and root cervix (Fig. 9I–II). In clinical cases, when CA intrudes the lower incisors, the roots of the teeth often protrude from the labial alveolar bone, and the risk reason is unknown. The results of this paper reveal the reason for this phenomenon, which has guiding significance for the clinical application of CA.
The canine crown tended to rotate distally, the apex tended to rotate mesially, and the CR tended to move mesially. Therefore, the tendency of the root to move mesially was greater than the tendency of the crown to move mesially. In the labiolingual direction, the canine crown tended to rotate lingually. In the vertical direction, the crown tended to extrude. The movement trend of the canine did not change significantly with the increase in the initial IMPA of the incisors (Fig. 9III, IV). The results suggest that during the intrusion of incisors, the force generated by the structural deformation of the CA also caused the root of the canine to move labially and mesially, which explained the common clinical phenomenon.
Discussion
Leveling the COS is a critical step in orthodontic treatment. The process of orthodontic treatment consists of three steps: aligning the teeth, bite opening and space closure, and fine adjustment. Therefore, for almost all orthodontic patients, the problem of intrusion of the lower incisors will be involved. Especially for patients with class II malocclusion and deep overbite, there are often different degrees of lip inclination compensation in the mandibular incisors, and the intrusion problem of the lower incisors is more arduous. Understanding the force and movement trend of the lower incisors of different IMPAs during the intrusion is a key factor in the successful treatment. CA is widely used in clinical practice, but the intrusion of lower incisors is often accompanied by unexplained root penetration from the labial alveolar bone, resulting in the risk of fenestration and dehiscence. Therefore, the mechanical study of CA intruding incisors has been a research hotspot for a long time.
3D finite element analysis is a classic biomechanical research method. The fineness of the meshing of the finite element model, the parameters of the materials, and the boundary conditions are directly related to the reliability of the simulation results. To study whether the initial biological response of tooth movement started in the alveolar bone or the PDL, Kawarizadeh et al. [15] used rat tissue sections to reconstruct a model including the right maxillary first molar, PDL, and alveolar bone. All bodies were meshed by solid elements (8 node quadrangular prism elements). The number of nodes was 8000. The results showed that the stress and strain distribution of the PDL was consistent with the distribution of osteoclasts, suggesting that the mechanical force induced by the PDL and surrounding osteoclasts was the main factor for tooth movement. To establish a complete 3D FE model of the maxillary second molar and verify its authenticity, Tajima et al. [16] used micro-CT to establish a 3D model of the isolated tooth, including pulp, dentin, and enamel, but not including PDL. The model was meshed into 10 node tetrahedral elements. The numbers of elements and nodes were 20,773 and 30,718, respectively. They compared the strain calculated by finite element analysis and the strain measured in vitro. The regression coefficient and standard error were 0.84 and 0.06, respectively, indicating that the FE model reconstructed from micro-CT data can be used as an effective model to analyze actual strain with acceptable accuracy. To study the effect of attachments on the closure of the maxillary central incisor space by the CA, Yokoi et al. [7] scanned a standard teaching model (i21D-400C, Nissin Dental Products Inc., Tokyo, Japan) by CBCT to establish a model including the maxillary dentition, PDLs, and alveolar bone. In the model, the PDL was set as a 0.2 mm uniform solid around the outer surface of the root. The teeth were divided into triangular shell elements, and the PDLs were meshed by 6-node triangular prismatic solid elements. Teeth and PDLs had a total of 67,210 units and 33,860 nodes. The results revealed that the attachments can assist the bodily movement of the central incisors. In this experiment, an industrial CT with a slice of 0.1 mm was used to scan a standard mandibular model for finite element modeling. PDLs with a uniform thickness of 0.3 mm were constructed on the roots [9]. The teeth were divided into 96,018 tetrahedral elements, and the PDLs were divided into 308,219 hexahedral elements. Existing studies have shown that in finite element analysis, the smaller the mesh element volume is, the more accurate the nonlinear continuous structure of the PDL that can be mapped, and the calculation results are more accurate [17]. Compared with the previous study, the elements of this study were divided more finely, and the quantity was larger. Compared with single-tooth modeling, the modeling of the mandibular dentition in this study more realistically reflected the interaction between teeth during intrusion. The results of this study were the stress distribution and the potential tooth movement trend during the intrusion, while the reconstruction process of the alveolar bone was not discussed. Therefore, the modeled object did not include the alveolar bone.
In this study, CA was the key force-applying tool to move the teeth, and its young’s modulus and structure should be as close as possible to the real situation. According to the existing research, at 37 °C, the elastic modulus of Invisalign is 842 ± 63 MPa, which is composed of TPU materials [18]. At 37 °C, the elastic modulus of Duran and Erkodur is 2015 ± 132.229 MPa and 1365.150 ± 262.883 MPa, respectively, both of which are composed of PTEG [19]. MC-S is a multilayer composite material, including TPU and PETG. According to ISO 527-3 [20], type 5B specimens were prepared with the material. The value of Young’s Modulus was established after performing compression tests (using an InstronH Universal Testing Machine). Finally, the Young's modulus of MC-S is 1000 MPa. In previous studies, CA was constructed as solid bodies with uniform thickness expansion along the crown shape, ranging from 0.3 to 0.75 mm [7, 21, 22]. However, in clinical practice, the thickness of the CA is nonuniform after the thermoform, and the structural characteristics of the CA have an important influence on the mechanics. Yue et al. [23] used reverse engineering technology to construct a simulated CA model with nonuniform thickness by scanning solid aligners. In this way, CA needs to be produced first and then scanned one by one to build models, which is difficult to achieve in research. Barone et al. [12] pointed out that the thickness of the CA diaphragm was 0.75 mm before thermoforming, so it is reasonable to set the CA to approximately 0.7 mm in the model after thermoforming. However, such a simulation was far from clinical reality. In the study of Gabriele et al. [8], the thickness of the Invisalign obtained by micro-CT scanning was 0.5 mm. Therefore, they expanded it uniformly along the outer surface of the crown by 0.5 mm and then smoothed it to obtain the CA model. In this paper, we used clinically applied software to simulate the thermoform and construct the structure of the CA to obtain a more realistic simulation model. Compared with the existing models, this CA model was more authentic.
The coefficient of friction (μ, the ratio of frictional force to positive pressure) between teeth and CA was an important setting for the study, but the value of μ is controversial in previous studies. In the studies of Barone et al. [12, 24] and Li et al. [25], μ was set to 0 because of the large material differences between teeth and CA and the presence of saliva as lubrication [12]. In other studies [26–30], μ was set to 0.2, which was similar to the friction coefficient between enamel and composite [26]. In the study of Goto et al. [31], μ was set to 0.5. In this study, μ was set to 0.3, which was the data obtained through the friction coefficient measurement experiment between the CA and teeth (refer to GB/T10006-2021 Plastics-Film and sheeting-Determination of the coefficients of friction).
Different patients have different inclinations of the lower incisors before treatment, which directly affects the distribution of force. Therefore, it is necessary to set appropriate IMPA groups to reflect different situations of patients with class II malocclusion. The study of Brezniak et al. [32] revealed that the average IMPA of Class II division 1 was 97.7 ± 6.4°, and the average IMPA of Class II division 2 was 97.4 ± 7.4°. The mandibular incisors of Class II malocclusion display compensatory labial inclination. Liu et al. [33], de Brito et al. [5], and Ni et al. [4] all used the upright mandibular incisor model when studying the intrusion of the mandibular incisors. To explore the effect of different IMPA on the force system and movement trend of mandibular anterior teeth during the intrusion, the initial IMPA was set to 90°, 95°, 100°, 105°, and 110° according to common compensatory inclination angles. Deep bite and deep COS can be seen in different malocclusions. Since the IMPA grouping in this research was set according to the Class II malocclusion, we mainly discuss the intrusion situation of the Class II malocclusion in the article. The results revealed that the force of the mandibular incisors was different under different initial IMPA, and the rotation direction of the teeth was reversed between 95° and 105°. In the clinical use of CA to intrude mandibular incisors, when the IMPA is less than or equal to 95°, lingual cervical bone dehiscence and labial apical bone fenestration may occur. When the IMPA was 100°, the central incisors were still at risk of apical labial penetration. For lateral incisors, labial cervical dehiscence and lingual apical fenestration may occur, while the cervical root protrudes to the labial alveolar bone. When the IMPA is 105°, both the central incisors and the lateral incisors may develop labial cervical dehiscence and lingual apical fenestration.
Different anterior tooth intrusion designs have a significant impact on the intrusion effect on mandibular incisors and canines, and the anchorage teeth always receive extrusive force. Liu et al. [33] used 3D printed CA with different designs to intrude the mandibular anterior teeth on a standard model (P12P-SB1, Nissin Dental Products Inc., Tokyo, Japan). Groups were set as a control group (G0), intrusion of canines only (G1), intrusion of incisors only (G2), intrusion of incisors and canines by the same activation (G3), and intrusion of incisors and canines by different activation (G4). In the first four designs, teeth were intruded by 0.2 mm. In G4, central incisors, lateral incisors, and canines were intruded by 0.2 mm, 0.15 mm, and 0.1 mm, respectively. Rectangular attachments were designed on the premolars and first molars, and a force sensor was used to record the vertical force value. The results showed that the canines in G2, the premolars and molars in G3, and the canines and premolars in G4 were subjected to extrusive force, that is, when the target intrusive activation was different, the adjacent teeth next to the maximum activation teeth and anchorage teeth were subjected to extrusive force. In our study, the mandibular incisors were intruded by 0.2 mm with the canines as anchors. The results showed that the canines were always subjected to extrusive force, and the central incisors and lateral incisors were subjected to intrusive force, but the intrusive force of the lateral incisors was always greater than that of the central incisors. This study also found that the canines were simultaneously subject to distal crown tip, mesial movement, and crown lingual rotation, suggesting that the root and periodontal health of anchoring teeth also needs attention in clinical practice.
Although finite element method is a classical mechanical simulation research method, it also has its limitations [34]. It is a computerized in vitro study [35] that can provide a reference for clinical practice and follow-up clinical research, but it cannot be completely equivalent to clinical trials and cannot directly guide clinical practice. Evidence at a higher level needs to be obtained through follow-up clinical trials.
Conclusions
The result of lower incisor intrusion is obviously related to the initial IMPA. When the initial IMPA increased from 90° to 110°, the labiolingual rotation direction of the incisors reversed, but the root of the incisor always tended to tipped labially. As an anchor, the canine experienced extrusion, distal crown tip, and lingual crown rotation. It is suggested that in CA cases, root movement can still lead to alveolar bone damage despite the use of opposite moment. The results of this study explained why this phenomenon occurs. When CA is used to intrude mandibular incisors, the treatment steps should be designed according to the initial IMPA, and the structural design of CA should be improved in the future to optimize the mechanical properties to prevent the above complications.
Acknowledgements
This work was supported by the National Natural Science Foundation of China [11932012] and the Clinical Research Plan of Shanghai Hospital Development Center [SHDC2020CR3009A].
Abbreviations
- CA
Clear aligner
- FE
Finite element
- PDL
Periodontal ligament
- IMPA
Incisor mandibular plane angles
- CR
Center of resistance
- COS
Curve of Spee
- CBCT
Cone-beam computed tomography
Author contributions
YL involved in conceptualization, data curation, formal analysis, investigation, methodology, project administration, visualization, roles/writing—original draft. SX took part in formal analysis, investigation, methodology. YJ involved in investigation, visualization. CZ took part in methodology, software. RL involved in investigation, visualization. YZ took part in data curation, formal analysis, methodology, software. RC involved in data curation, formal analysis, methodology, resources, validation. LX took part in data curation, funding acquisition, project administration, resources, supervision. BF involved in conceptualization, funding acquisition, investigation, project administration, resources, supervision, validation, writing—review & editing. All authors gave final approval and agreed to be accountable for all aspects of the work. All authors read and approved the final manuscript.
Funding
This work was supported by the National Natural Science Foundation of China [11932012] and the Clinical Research Plan of Shanghai Hospital Development Center [SHDC2020CR3009A].
Availability of data and materials
Please contact authors for data requests.
Declarations
Ethics approval and consent to participate
Not applicable.
Concent for publication
All the participants’ informed consents were obtained.
Competing interests
The authors declare that they have no competing interests.
Footnotes
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Contributor Information
Rongjing Chen, Email: Chen_rongjing@yeah.net.
Lunguo Xia, Email: xavierxlg@126.com.
Bing Fang, Email: fangbing@sjtu.edu.cn.
References
- 1.Weir T. Clear aligners in orthodontic treatment. Aust Dent J. 2017;62(Suppl 1):58–62. doi: 10.1111/adj.12480. [DOI] [PubMed] [Google Scholar]
- 2.Kravitz ND, Kusnoto B, BeGole E, Obrez A, Agran B. How well does Invisalign work? A prospective clinical study evaluating the efficacy of tooth movement with Invisalign. Am J Orthod Dentofacial Orthop. 2009;135(1):27–35. doi: 10.1016/j.ajodo.2007.05.018. [DOI] [PubMed] [Google Scholar]
- 3.Al-Balaa M, Li H, Ma Mohamed A, Xia L, Liu W, Chen Y, et al. Predicted and actual outcome of anterior intrusion with Invisalign assessed with cone-beam computed tomography. Am J Orthod Dentofacial Orthop. 2021;159(3):e275–e280. doi: 10.1016/j.ajodo.2020.10.018. [DOI] [PubMed] [Google Scholar]
- 4.Ni J, Zhang M, Ge Z. Application of Three-Dimensional Digital Technology in Invisible Orthodontic Treatment. In: Sugumaran V, Xu Z, Zhou H, editors. Application of Intelligent Systems in Multi-modal Information Analytics. Cham: Springer International Publishing; 2021. p. 410-8.
- 5.de Brito GM, Brito HHA, Marra GGM, Freitas LRP, Hargreaves BO, Magalhaes PAA, et al. Pure mandibular incisor intrusion: a finite element study to evaluate the segmented arch technique. Materials (Basel) 2019 doi: 10.3390/ma12172784. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 6.Cortona A, Rossini G, Parrini S, Deregibus A, Castroflorio T. Clear aligner orthodontic therapy of rotated mandibular round-shaped teeth: a finite element study. Angle Orthod. 2020;90(2):247–254. doi: 10.2319/020719-86.1. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 7.Yokoi Y, Arai A, Kawamura J, Uozumi T, Usui Y, Okafuji N. Effects of attachment of plastic aligner in closing of diastema of maxillary dentition by finite element method. J Healthc Eng. 2019;2019:1075097. doi: 10.1155/2019/1075097. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 8.Gabriele R, Stefano M, Simone P, Andrea D, Tommaso C. Incisors extrusion with clear aligners technique: a finite element analysis study. Appl Sci. 2021;11(3):1167. doi: 10.3390/app11031167. [DOI] [Google Scholar]
- 9.de Jong T, Bakker AD, Everts V, Smit TH. The intricate anatomy of the periodontal ligament and its development: lessons for periodontal regeneration. J Periodontal Res. 2017;52(6):965–974. doi: 10.1111/jre.12477. [DOI] [PubMed] [Google Scholar]
- 10.Xiao S, Xiangfei Kong, Yao J, Liu J, Li L, Jiang T, Wang L, Fan Y. Differences in root stress and strain distribution in buccal and lingual orthodontics: A finite element analysis study. Med Novel Technol Devices. 2022;14:119. doi: 10.1016/j.medntd.2022.100119. [DOI] [Google Scholar]
- 11.Gerhard W, Boyer RR, Collings EW. Materials properties handbook: titanium alloys. ASM International; 1994. [Google Scholar]
- 12.Barone S, Paoli A, Razionale AV, Savignano R. Computational design and engineering of polymeric orthodontic aligners. Int J Numer Methods Biomed Eng. 2017 doi: 10.1002/cnm.2839. [DOI] [PubMed] [Google Scholar]
- 13.Premkumar S. Essential diagnostic aids: essential radiographs and clinical photographs. In: Premkumar S, editor. Textbook of orthodontics. New Delhi: Reed Elsevier India Pvt. Ltd; 2015. p. 280. [Google Scholar]
- 14.Burstone CJ. The biomechanics of tooth movement. In: Bertram SK, Richard AR, editors. Vistas in orthodontics presented to Alton W Moore. Pennsylvania: Lea & Febiger;1962. p.200.
- 15.Kawarizadeh A, Bourauel C, Zhang D, Gotz W, Jager A. Correlation of stress and strain profiles and the distribution of osteoclastic cells induced by orthodontic loading in rat. Eur J Oral Sci. 2004;112(2):140–147. doi: 10.1111/j.1600-0722.2004.00116.x. [DOI] [PubMed] [Google Scholar]
- 16.Tajima K, Chen KK, Takahashi N, Noda N, Nagamatsu Y, Kakigawa H. Three-dimensional finite element modeling from CT images of tooth and its validation. Dent Mater J. 2009;28(2):219–226. doi: 10.4012/dmj.28.219. [DOI] [PubMed] [Google Scholar]
- 17.Romanyk DL, Vafaeian B, Addison O, Adeeb S. The use of finite element analysis in dentistry and orthodontics: critical points for model development and interpreting results. Semin Orthod. 2020;26(3):162–173. doi: 10.1053/j.sodo.2020.06.014. [DOI] [Google Scholar]
- 18.Dalaie K, Fatemi SM, Ghaffari S. Dynamic mechanical and thermal properties of clear aligners after thermoforming and aging. Prog Orthod. 2021;22(1):15. doi: 10.1186/s40510-021-00362-8. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 19.Fang D, Li F, Zhang Y, Bai Y, Wu BM. Changes in mechanical properties, surface morphology, structure, and composition of Invisalign material in the oral environment. Am J Orthod Dentofac Orthoped Offi Publ Am Assoc Orthod Const Soc Am Board Orthod. 2020;157(6):745–753. doi: 10.1016/j.ajodo.2019.05.023. [DOI] [PubMed] [Google Scholar]
- 20.Plastics—Determination of tensile properties—Part 3: Test conditions for films and sheets. International Organization for Standardization. 1995.
- 21.Kim WH, Hong K, Lim D, Lee JH, Jung YJ, Kim B. Optimal position of attachment for removable thermoplastic aligner on the lower canine using finite element analysis. Materials (Basel) 2020 doi: 10.3390/ma13153369. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 22.Seo JH, Eghan-Acquah E, Kim MS, Lee JH, Jeong YH, Jung TG, et al. Comparative analysis of stress in the periodontal ligament and center of rotation in the tooth after orthodontic treatment depending on clear aligner thickness-finite element analysis study. Materials (Basel) 2021 doi: 10.3390/ma14020324. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 23.Yue Y, Wang Y, Zhang Y. The Construction of Finite Element Model of Invisible Appliance of Inhomogeneous Thickness by Reverse Engineering Technology. Applied Mechanics and Materials. 2015;741:254-7. 10.4028/www.scientific.net/AMM.741.254.
- 24.Savignano R, Barone S, Paoli A, Razionale AV. Computer aided engineering of auxiliary elements for enhanced orthodontic appliances. In: Eynard B, Nigrelli V, Oliveri SM, PerisFajarnes G, Rizzuti S, editors. Advances on mechanics, design engineering and manufacturing. lecture notes in mechanical engineering, 2017. pp. 405–14.
- 25.Li R, She W, Luo Y, Wang J, Peng Y, Ye Q. The optimal activation of plastic aligner for canine distal movement: a three-dimensional finite element analysis. Odontology. 2021 doi: 10.1007/s10266-021-00663-8. [DOI] [PubMed] [Google Scholar]
- 26.Gomez JP, Peña FM, Martínez V, Giraldo DC, Cardona CI. Initial force systems during bodily tooth movement with plastic aligners and composite attachments: a three-dimensional finite element analysis. Angle Orthod. 2015;85(3):454–460. doi: 10.2319/050714-330.1. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 27.Ramalho A, Antunes PV. Reciprocating wear test of dental composites against human teeth and glass. Wear. 2007;263(7–12):1095–1104. doi: 10.1016/j.wear.2007.01.086. [DOI] [Google Scholar]
- 28.Xu N, Lei X, Yang X, Li X, Ge Z. Three-dimensional finite element analysis on canine teeth distalization by different accessories of bracket-free invisible orthodontics technology. In: Liu L, Yang C, Ke J, editors. Advances in Materials, Machinery, Electronics Ii. AIP Conference Proceedings, 2018.
- 29.Jiang T, Wu RY, Wang JK, Wang HH, Tang GH. Clear aligners for maxillary anterior en masse retraction: a 3D finite element study. Sci Rep. 2020;10(1):10156. doi: 10.1038/s41598-020-67273-2. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 30.Ayidağa C, Kamiloğlu B. Effects of variable composite attachment shapes in controlling upper molar distalization with aligners: a nonlinear finite element study. J Healthc Eng. 2021;2021:5557483. doi: 10.1155/2021/5557483. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 31.Goto M, Yanagisawa W, Kimura H, Inou N, Maki K. A method for evaluation of the effects of attachments in aligner-type orthodontic appliance: three-dimensional finite element analysis. Orthod Waves. 2017;76(4):207–214. doi: 10.1016/j.odw.2017.09.001. [DOI] [Google Scholar]
- 32.Brezniak N, Arad A, Heller M, Dinbar A, Dinte A, Wasserstein A. Pathognomonic cephalometric characteristics of angle class II division 2 malocclusion. Angle Orthod. 2002;72(3):251–257. doi: 10.1043/0003-3219(2002)072<0251:PCCOCI>2.0.CO;2. [DOI] [PubMed] [Google Scholar]
- 33.Liu Y, Hu W. Force changes associated with different intrusion strategies for deep-bite correction by clear aligners. Angle Orthod. 2018;88(6):771–778. doi: 10.2319/121717-864.1. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 34.Kolata GB. The finite element method: a mathematical revival. Science. 1974;184(4139):887–889. doi: 10.1126/science.184.4139.887. [DOI] [PubMed] [Google Scholar]
- 35.Trivedi S. Finite element analysis: a boon to dentistry. J Oral Biol Craniofac Res. 2014;4(3):200–203. doi: 10.1016/j.jobcr.2014.11.008. [DOI] [PMC free article] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Data Availability Statement
Please contact authors for data requests.