Skip to main content
Scientific Reports logoLink to Scientific Reports
. 2023 Feb 14;13:2582. doi: 10.1038/s41598-023-29812-5

Engineered kirigami design of PVDF-Pt core–shell nanofiber network for flexible transparent electrode

Heesung Park 1, Hyeokjun Si 1, Junseo Gu 1, Donghyun Lee 1, Donghyuck Park 1, Young-In Lee 2, Kwanlae Kim 1,
PMCID: PMC9929047  PMID: 36788304

Abstract

Nanofiber networks comprising polymer-metal core–shell structures exhibit several advantages, such as high uniformities and considerable flexibilities. Additionally, the flexibility of the nanofiber network may be further enhanced by engineering the network topology. Therefore, in this study, the topologies of polyvinylidene fluoride (PVDF)-Pt core–shell nanofiber (CS NF) networks were engineered, and their performances as flexible transparent electrodes were comprehensively evaluated. Three distinct topologies of nanofiber networks were induced using circular, square, and rectangular electrode collectors. A highly uniform nanofiber network was obtained using the square electrode collector, which generated a high density of nanofiber junctions (nodes). Consequently, this nanofiber network exhibited the smallest sheet resistance Rs and lowest optical transmittance T among the three CS NF networks. In contrast, nanofiber bundles were frequently formed in the randomly aligned CS NF network prepared using the circular electrode collector, reducing the node density. As a result, it simultaneously exhibited a very small Rs and high T, generating the largest percolation figure of merit Π=330.5. Under certain strain directions, the CS NF network with the engineered topology exhibited a significantly enhanced mechanical durability. Finally, a flexible piezoelectric pressure sensor with CS NF network electrodes was fabricated and its sensing performance was excellent.

Subject terms: Engineering, Materials science, Nanoscience and technology

Introduction

The advancement of flexible transparent electrode (FTE) technology has been fostered by demand for next-generation electronic devices1,2. Indium tin oxide (i.e. In2O3: Sn) is widely used as a TE because of its low sheet resistance Rs<80Ω/sq. at a high optical transmittance T=90%,550nm3,4. However, it exhibits critical problems, such as a low abundance of indium and mechanical brittleness5. Accordingly, over the last decade, intensive research was conducted regarding nanostructured transparent conductors6. In these FTEs, nanomaterials, such as metal nanowires and carbon nanotubes, form conducting networks, resulting in excellent flexibilities, in addition to small Rs102-103Ω/sq. values at high T90%,550nm values7,8.

In these nanostructured transparent conductors, the percolation figure of merit Π and exponent (n) may be optimized by engineering the lengths9 and dispersion uniformities of 1D nanomaterials10. Nanofibers fabricated via electrospinning exhibit several advantages, such as high aspect ratios and uniformities, and are formed via facile fabrication processes11. Therefore, FTEs based on nanofiber networks were developed for various structures, e.g., a Cu nanofiber network exhibited a competitive Rs50Ω/sq. at a high T (90%, 550 nm)12,13. However, the performance of a metal nanofiber network as a TE is limited owing to the junction resistance between the nanofibers14. This constraint of the metal nanofiber network was overcome using a polymer nanofiber network as a template, upon which metal materials were directly deposited1517. Due to the directionality of the thin film deposition processes, the deposited metal materials take a nanotrough structure. Subsequently, by dissolving the polymer template using an organic solvent or water, nanotrough networks were fabricated from the highly conductive metals such as Cu, Ag, Al and Au. Although this network is a competitive FTE in terms of a low Rs and high T (e.g., the Rs values of Cu, Au, and Ag at 90% T are <10Ω/sq.), the fabrication process is complicated15. From this perspective, a polymer-metal core–shell nanofiber (CS NF) network displays several advantages1824. The fabrication process, which comprises only two steps (electrospinning and thin-film deposition), is applicable to numerous highly conductive materials. Furthermore, under tensile strain, the metal film deposited on a soft polymer forms multiple necks, delaying rupture and enhancing the mechanical durability of the metal film conductor18,25,26.

Generally, the flexibilities of stiff materials may be drastically improved by employing serpentine or network structures27,28. Nanofiber networks intrinsically adopt Kirigami designs, providing considerable structural flexibilities. Furthermore, when a nanofiber network exhibits a serpentine structure, the flexibility of the electrode is further enhanced, e.g., the mechanical durabilities of a polyvinylpyrrolidone(PVP)-Au CS NF network and an Au nanotrough network were considerably enhanced under stretching by employing buckled nanofibers29,30. Additionally, the stretchability of the network structure is highly influenced by topology, e.g., the stretchabilities of Au nanomesh electrodes were considerably enhanced (e.g., no noticeable fatigue after repetitive stretching to > 100% strain) via a theoretical approach in designing the optimal topology31. Similarly, the flexibility of the nanofiber network may be further enhanced by engineering the network topology. In this case, the nanofiber network fabricated via electrospinning is advantageous because the alignment of nanofibers may be controlled by designing the pattern of the electrode collector3234.

In this study, three distinct topologies of polyvinylidene fluoride (PVDF) nanofiber networks were prepared using circular, square, and rectangular electrode collectors. PVDF-Pt CS NF networks were fabricated by coating the PVDF nanofibers with Pt. The Π values of the three distinct fiber networks were evaluated by measuring Rs and T. The flexibilities of the nanofiber networks were assessed via bending and stretching studies. Finally, the PVDF-Pt CS NF network electrodes were applied in flexible piezoelectric pressure sensors to demonstrate their performances as electrodes. To the best of our knowledge, a polymer-metal CS NF network has not been used as the electrodes of piezoelectric pressure sensors, in which strong electric field should be applied through the electrodes for an electrical poling process. Flexible and transparent pressure sensors can be applied to electronic skins and wearable self-powered touch sensors in which excellent transparency and flexibility are simultaneously required to enhance wearing sensation, aesthetics, and security in military applications35,36.

Methods

Fabrication of the PVDF-Pt CS NF networks

The PVDF nanofiber was used as the core material because of its high flexibility37. PVDF powder (1.5 g, molecular weight ≈ 534 000 g/mol, Sigma Aldrich, St. Louis, MO, USA) was dissolved in 8.5 g of the solvent via stirring at 100 °C for 1 h to prepare a PVDF solution with a concentration of 15 wt.%. The solvent consisted of 7 mL acetone (Duksan Reagents, Ansan, Republic of Korea) and 3 mL dimethylformamide (Duksan Reagents). The PVDF nanofibers were produced using an electrospinning/-spray system (ESR200, NanoNC, Seoul, Republic of Korea). In this study, fabricating a free-standing PVDF nanofiber network was essential in ensuring that the nanofibers could be conformally coated with Pt during sputtering. Free-standing PVDF nanofiber networks may be produced under specific voltage and tip-to-collector distance (TCD) conditions38. In this study, a TCD, voltage, and solution flow rate of 17 cm, 10 kV, and 40 μL/min, respectively, were consistently used during electrospinning. As shown in Fig. 1, circular (0.021 m radius), square (0.042 × 0.042 m), and rectangular (0.11 × 0.042 m) electrode collectors were used to control the topologies of the PVDF nanofiber networks. The electrode collectors, which were comprised of stainless steel, were placed 2 cm above the floor to prevent the PVDF nanofibers from adhering to the floor.

Figure 1.

Figure 1

Schematic diagram of the fabrication processes of the CS NF networks, comprising PVDF electrospinning, Pt sputtering, and transferring to a PDMS substrate. The piezoelectric composite comprising a PDMS matrix and BTO@PDA nanoparticles is sandwiched by the top and bottom CS NF networks on PDMS substrates to fabricate a piezoelectric pressure sensor.

Pt was used as an electrode material due to its high electrical conductivity and resistance to oxidation and corrosion39. Nevertheless, depending on the specific applications of electrode materials, other cost-effective metals may be also considered as an electrode material. Prior to deposition of the Pt layer, the PVDF nanofibers were heated (80 °C for 2 h) in an oven to remove the residual solvent. The PVDF nanofibers were coated with Pt via direct-current magnetron sputtering (KVS-2000, Korea Vacuum Tech, Gimpo, Republic of Korea) with a Pt sputter target (99.999% purity, RND Korea, Gwangmyeong, Republic of Korea). Sputtering was used as the thin-film deposition technique because sputtered atoms are scattered by the inert gas in the chamber, resulting in a wide range of incidence angles to the PVDF nanofibers. Additionally, sputtering does not typically require a high-temperature environment, and thus, it is suitable for use in coating metals onto PVDF nanofibers. Sputtering was performed at base and working pressures of 2×10-5Torr and 15 mTorr, respectively, and a power of 150 W. Finally, the resultant CS NF networks were transferred to polydimethylsiloxane (PDMS) substrates for use in fabricating the piezoelectric pressure sensors.

Fabrication of the piezoelectric pressure sensors

BaTiO3 (BTO) nanoparticles were functionalized with polydopamine (PDA)40,41, as described in the Supplementary Information. BTO@PDA nanoparticles (6 g) were ultrasonically dispersed in 14 g ethanol (Duksan Reagents) for 1 h. Subsequently, 14 g of PDMS resin (Sylgard 184 Silicone Elastomer Kit, Dow Corning, Midland, MI, USA) was added to the solution and dispersed for 30 min. The solution was stirred at 60 °C at 300 rpm for 24 h to evaporate the residual ethanol. Crosslinker (1.4 g, Sylgard 184 Silicone Elastomer Kit, Dow Corning) was then added to cure the solution. Finally, a PDMS/BTO@PDA composite layer was prepared via spin coating at 400 rpm for 1 min and annealing at 100 °C for 2 h in an oven.

As shown in Fig. 1, the prepared PDMS/BTO@PDA composite layer is bonded to the CS NF network electrodes on PDMS substrates. During this process, the contact surfaces of the electrodes and PDMS/BTO@PDA layer are treated with oxygen plasma to enhance chemical adhesion during bonding42. Subsequently, the PDMS/BTO@PDA composite layer sandwiched between the top and bottom electrodes is annealed at 60 °C for 35 min in an oven. Finally, DC electrical poling was conducted on the PDMS/BTO@PDA composite through the CS NF networks at an electric field intensity of 30 MV/m for 1 h at room temperature.

Characterizations

The fabricated CS NF networks were transferred to PDMS substrates for use in conductive atomic force microscopy (C-AFM), T measurements, and mechanical durability studies. Slide glass and Si wafers were used as substrates in Rs measurements and energy dispersive X-ray spectroscopy (EDS), respectively. The topologies of the nanofiber networks were studied using scanning electron microscopy (SEM, JSM-6700F, JEOL, Tokyo, Japan), which was also used to analyze the surface quality of the Pt layer and cross-section of the PVDF-Pt CS NF. The orientations of the PVDF nanofibers in these nanofiber networks were analyzed using ImageJ software (National Institutes of Health, Bethesda, MD, USA) in conjunction with the SEM images. More specifically, OrientationJ, which is an ImageJ plug-in, was used to statistically analyze the orientation of PVDF nanofibers. EDS (SU8010, Hitachi, Tokyo, Japan) was used to conduct elemental mapping of the PVDF-Pt CS NFs, and their electrical conductivities were measured using C-AFM. A C-AFM module and current amplifier were installed in an AFM (XE-150, Park Systems, Suwon, Republic of Korea)43, and a probe (ElectriMulti75-G, BudgetSensors, Sofia, Bulgaria) with a spring constant of 3 N/m was used to ensure good electrical contact between the AFM probe and the nanofibers. AFM measurements were typically conducted at a set point and scan rate of 30 nN and 0.5 Hz, respectively, with a tip bias of 5 mV applied during C-AFM.

The Rs of the CS NF network was measured using the four-point probe method (M4P-302, MSTECH, Hwaseong, Republic of Korea) interfaced with a source measure unit (2612B, Keithley Instruments, Cleveland, OH, USA). Optical analysis was conducted by an ultraviolet–visible spectrophotometer (Specord 200 PLUS, Analytik Jena, Jena, Germany) and a haze meter (NDH 5000, Nippon Denshoku, Japan). To measure the changes in the resistances of the CS NF networks induced by mechanical strain, the resistance between the two ends of the rectangular sample was monitored. A bending tester (JIBT-200, Junil Tech, Republic of Korea) interfaced with a source meter was used to evaluate the mechanical durability of the CS NF network.

Transmission electron microscopy (TEM, JEM-2010, JEOL) was used to observe the thicknesses of the PDA layers of the BTO@PDA nanoparticles. X-ray photoelectron spectroscopy (XPS, K-Alpha+, Thermo Fisher Scientific, Waltham, MA, USA) was used to determine the chemical compositions of the PDA layers, and the XP spectra were analyzed using a fitting program (Avantage Data System (Thermo Fisher Scientific) and CasaXPS (Casa Software, Teignmouth, UK)). The dielectric properties of the PDMS/BTO@PDA composites were studied using an LCR meter (E4980AL, Keysight Technologies, Santa Rosa, CA, USA). Finally, the leakage current of the composite was measured using a ferroelectric measurement system (TF 1000, aixACCT Systems, Aachen, Germany) interfaced with a high-voltage amplifier (Trek 10/10B-HS, Advanced Energy, Denver, CO, USA).

Results and discussion

The advantage of the nanostructured conductor based on electrospun nanofibers lies in the controllable topology of the nanofiber network according to the shape of electrode collector34. Figure 2a shows the three types of electrode collectors and PVDF nanofibers formed via electrospinning. Magnified images of the nanofibers formed using the circular, square, and rectangular electrode collectors are shown in Fig. 2a. The orientations of the PVDF nanofibers in these nanofiber networks were analyzed using OrientationJ. This program computes a structure tensor for each pixel and is often used to identify the local orientation of each pixel of the image44,45. For the present study, the size of local window σ was set as 1 pixel, and the Gaussian method was used to numerically estimate gradients. The minimum energy of 1% was applied to ignore the background noise originating from the substrate. OrientationJ has been often used to analyze the orientation of nanofibers46,47. This methodology was applied to twelve CS NF network samples. As shown in Supplementary Fig. S1, whereas no distinct peak is consistently observed for the nanofiber alignment obtained using the circular electrode collector, strong peaks may be clearly and consistently observed for those obtained using the square and rectangular electrode collectors. As shown in Supplementary Fig. S1b, the peaks near 0° and ± 90° indicate that most PVDF nanofibers are closely oriented in the horizontal and vertical directions, respectively. Conversely, as shown in Supplementary Fig. S1c, the peak near ± 90° represents vertically oriented nanofibers. Notably, using the square and rectangular electrode collectors, numerous nanofibers are slightly deviated from the horizontal and vertical orientations. Additionally, as Supplementary Fig. S1d and e show, the average distance between neighboring nanofibers and the area fraction of nanofibers slightly varied from sample to sample. See the Supplementary Information for further details. Based on this result and the SEM images shown in Fig. 2a, the simplified topologies of the PVDF nanofibers may be shown by the schematic diagrams at the bottom of Fig. 2a. Meanwhile, using the circular electrode collector, numerous nanofibers coalesce during electrospinning, generating nanofiber bundles. Conversely, using the square electrode collector, the orientation of the PVDF nanofiber alignment is frequently changed from vertical to lateral or vice versa. This is because the electrostatic force acting on an electrified liquid jet and the square electrode collector has no preferential orientation between the two pairs of parallel electrodes of the square electrode collector33. This frequently switching orientation of the nanofiber alignment prevented the formation of nanofiber bundles, providing more uniformity in the nanofiber network. Supplementary Fig. S2 shows high-magnification SEM images of the PVDF nanofibers formed using the circular and square electrode collectors to reveal this difference.

Figure 2.

Figure 2

Topologies of the CS NF networks and characterization of a Pt-coated PVDF nanofiber. (a) PVDF nanofibers formed using the circular, square, and rectangular electrode collectors, and the magnified images of the nanofiber networks. The schematic diagrams show the simplified topologies of the nanofiber networks. SEM images of the (b) surface and (c) cross-section of a Pt-coated PVDF nanofiber, AFM topography images of a PVDF nanofiber (d) before and (e) after Pt sputtering, and C-AFM images of a PVDF nanofiber (f) before and (g) after Pt sputtering. The Pt sputtering time used for (b), (c), (e), and (g) was 4 min.

The surface of a Pt-coated PVDF nanofiber (4 min of sputtering) is shown in Fig. 2b. The sputtering conditions described in the Methods section enable the conformal coating by the Pt layer. Furthermore, Supplementary Fig. S3 shows that the junctions of the PVDF nanofibers are fused by the Pt layers, reducing the contact resistance between the nanofibers15,20. The core–shell structure may be clearly identified based on the cross-sectional view of the Pt-coated PVDF nanofiber shown in Fig. 2c. AFM and C-AFM were used to measure the diameters and electrical conductivities of the Pt-coated PVDF nanofibers, respectively. Figure 2d and e show the respective topographic images of a single PVDF nanofiber before and after Pt sputtering for 4 min. The measured diameter of the Pt-coated PVDF nanofiber shown in Fig. 2e is 2.72 μm, which is larger than that (1.71 μm) observed in the SEM image shown in Fig. 2b. This error is due to the finite response time of the AFM feedback system and the physical contact between the PVDF nanofiber and the sidewall of the AFM tip. In particular, this tip-related artefact occurs when a large object is imaged by an AFM tip4850. The size of PVDF nanofibers measured by AFM should vary depending on the size of the AFM tip. After Pt sputtering, the nanofiber diameter increases from 2.59 to 2.72 μm, with a growth rate of 32.5 nm/min, as shown in Fig. 2d and e. The deposition of the Pt layer on the PVDF nanofiber is confirmed by the C-AFM images. Compared with the C-AFM image captured before Pt sputtering (Fig. 2f), strong current signals 6.12nA are detected in the Pt-coated PVDF nanofiber (Fig. 2g). The presence of PVDF-Pt CS NFs is also indicated by the results of elemental mapping (Supplementary Fig. S4). The diameters of the PVDF nanofibers obtained using each electrode collector were statistically analyzed (Supplementary Fig. S5). The range of the average diameter is only 1.524–1.568 μm, depending on the shape of the electrode collector. Therefore, the effect of nanofiber size on the properties of the CS NF networks is not considered in this study.

Subsequently, to evaluate the performances of the CS NF networks as FTEs, their Rs and T values were assessed. The Rs values of the CS NF networks depend strongly on their sputtering and electrospinning times. As shown in Fig. 3a, the Rs of the CS NF network obtained using the circular electrode collector was measured at various sputtering times from 2 to 6 min. When the sputtering time is 6 min, Rs decreases to approximately 11.29 Ω/sq., which is sufficiently low compared to those reported in the previous studies of FTEs based on nanofibers14,17,21,51. Therefore, a sputtering time of 6 min was consistently used during the fabrication of the CS NF networks. Thereafter, the Rs values of the CS NF networks were measured while gradually increasing the electrospinning time from 90 to 210 s. Notably, for the CS NF networks prepared using the square and rectangular electrode collectors, Rs depends on measurement direction, as shown in Supplementary Fig. S6. Thus, their average values are used in Fig. 3b. The CS NF network obtained using the square electrode collector exhibits the smallest Rs followed by those of the CS NF networks obtained using the circular and rectangular electrode collectors (e.g., at an electrospinning time of 210 s, Rssquare=6.97Ω/sq., Rscircle=9.94Ω/sq., and Rsrectangle=18.88Ω/sq.).

Figure 3.

Figure 3

Sheet resistances (Rs) and transmittances (T) of the CS NF networks obtained using the circular, square, and rectangular electrode collectors. (a) Rs of the CS NF network obtained using the circular electrode collector with respect to sputtering time, (b) Rs values of the CS NF networks with respect to electrospinning time, (c) T values of the CS NF networks (180 s electrospinning time) with respect to wavelength, and (d) T values (at 550 nm) of the CS NF networks with respect to Rs. (e) Number of nodes depending on the ideal and actual topologies.

Figure 3c shows the T values of the CS NF networks (electrospinning and sputtering times of 180 s and 6 min, respectively). The T values of the nanofiber networks decrease as the electrospinning time increases, regardless of the type of electrode collector used (Supplementary Fig. S7a–c). The relationship between transparency and electrospinning time may also be confirmed by directly comparing the images of the CS NF networks prepared at various electrospinning times (1.5–3.5 min, Supplementary Fig. S7d). Finally, the measured haze values of CS NF networks with respect to Rs are shown in Supplementary Fig. S7e. In nanostructured conductors, haze values are dependent on network densities52,53. The measured haze of the CS NF network ranged from 3.65 to 11.81% depending on electrospinning times (1.5–3.5 min), and the topologies of nanofiber networks. Among the CS NF network with 1.5 min electrospinning time, the smallest haze was measured from the CS NF network from the rectangular electrode collector (3.65%), followed by circular (5.02%) and square electrode collector (7.67%).

For the CS NF networks prepared using electrospinning times of 90–210 s, T at 550 nm wavelength with respect to Rs is shown in Fig. 3d. For each electrode collector, the plot may be divided into the percolation and bulk regimes7,8. As shown in Fig. 3d, the data points representing the bulk regime are shaded using ellipses and circles. Only the computed fit lines of the CS NF networks in the percolation regime are shown. The relationship between Rs and T in the percolation regime is typically described by7,8

T=1+1ΠZ0Rs1/n+1-2, 1

where Π, n, and Z0 are the percolation figure of merit and percolation exponent, and impedance of free space (377 Ω), respectively. The relationship between Rs and T in the percolation regime is clear in the plot of LogT-0.5-1 as a function of LogRs/Z0 (Supplementary Fig. S8). The Π and n values of the CS NF networks obtained using the circular, square, and rectangular electrode collectors were computed by applying the data shown in Fig. 3d to Eq. (1). The obtained Π and n data are shown in Table 1. Generally, excellent transparent conductors with small Rs and large T values display large Π and small n values7,8. The CS NF network obtained using the circular electrode collector exhibits the largest Π (330.5) and smallest n (0.026) compared to those of the CS NF networks obtained using the other electrode collectors (Πsquare=198.6, Πrectangle=168.2, nsquare=0.135, and nrectangle=0.238). The CS NF network obtained using the circular electrode collector simultaneously displays a very small Rs and high T compared to those of the other networks, as shown in Fig. 3b and c. Notably, the Π and n values of the CS NF networks fabricated in this study are outstanding compared to those of previously reported nanostructured transparent conductors (Table 1). This is attributed to three factors: the high uniformities of the electrospun nanofibers, the conformal coating of Pt via sputtering, and the low junction resistances.

Table 1.

Percolation exponents (n) and figures of merit Π of the CS NF networks fabricated in this study and those of the nanostructured transparent conductors reported in previous studies12,15,18,52,5461.

Nanostructured transparent conductors n Π References
PVDF-Pt core–shell nanofiber (Circle) 0.026 330.5 Present work
PVDF-Pt core–shell nanofiber (Square) 0.135 198.6 Present work
PVDF-Pt core–shell nanofiber (Rectangle) 0.238 168.18 Present work
Ag nanowires 1.9 31.7 54
Graphene 3.1 3.5 55
Cu nanofibers 0.43 75.37 12
Al nanotrough 0.33 48 15
Ag nanotrough 0.10 495 15
Au nanotrough 0.07 1030 15
Dip-coated long Ag nanowires 0.65 162.54 56
Dip-coated short Ag nanowires 1.62 58.04 56
Cell shaped Ag nanowires 1.48 46.43 57
Ag metallic network 1.58 54.64 58
Patterned Ag nanowires 0.13 291.61 59
Aligned Ag nanowires micro-grids 0.24 575.72 60
Epoxy-embedded Ag nanowires 1.19 52 61
Ag nanowire-SWCNT hybrid 0.37 245.8 52
Au coated nanofier 0.255 78.135 18

In comparison with those reported in earlier studies, the PVDF-Pt CS NF network prepared using the circular electrode collector exhibits an outstanding performance as a transparent conductor because of its large percolation figure of merit Π=330.5 and small percolation exponent n=0.026.

The effect of nanofiber network topology on Rs and T may be theoretically explained using node theory62. A large number of nodes (nanofiber junctions) facilitates charge transport but simultaneously reduces T. As shown in the schematic diagram (Fig. 3e), the number of nodes depends strongly on the type of electrode collector used. When three nanofibers are uniformly dispersed using each type of collector, the numbers of nodes are 3 (circles), 2 (squares), and 0 (rectangles). However, nanofiber bundles are frequently produced using the circular electrode collector, reducing the number of nodes to 1 (circle). Therefore, according to node theory, based on the actual topology, the smallest Rs may be expected upon using the square electrode collector, followed by those of the networks obtained using the circular and rectangular electrode collectors. In contrast, the highest T may be expected upon using the rectangular electrode collector, followed by those of the networks obtained using the circular and square electrode collectors. The experimental results shown in Fig. 3b and c may be clearly explained by node theory, based on the actual topology. It should be noted that there are actually a number of nodes in the nanofiber network from the rectangular electrode collector as the SEM image in Fig. 2a shows. Nodes can be generated by neighboring nanofibers unless nanofibers are perfectly parallel to each other. For this reason, the CS NF network from the rectangular electrode collector can be still electrically conductive along the nanofiber orientation. However, in general a node cannot be generated by the nanofibers far apart.

Meanwhile, the uniformity of Rs and T over the entire CS NF network generated within the electrode collector was also evaluated. In the present study, three square samples 1cm×1cm were taken from the locations shown in Supplementary Fig. S9c, and the measured Rs and T values are represented in Supplementary Fig. S9a and b, respectively. Note that Rs was measured from five different locations in each sample, and their averaged values were used in Supplementary Fig. S9a. For the CS NF networks from the square and rectangular electrode collectors, there were considerable differences in Rs and T between location 3 and the rest due to the non-uniform nanofiber alignments at the corners of the square and rectangular electrode collector. Therefore, in the present study all the CS NF network samples were taken from the central area of the electrode collectors for the characterizations and device fabrication. For the large-area fabrication of the nanofiber networks, the electrode collector with a larger diameter or side length may be used adjusting TCD and electrospinning voltage. In this way, the area of the nanofiber network with good uniformity can be also enlarged. Subsequently, the mechanical durabilities of the CS NF networks under mechanical stress were assessed via bending and stretching studies. First, the excellent flexibility of a CS NF network was compared to that of a Pt thin film via a bending study at a bending radius of 1 mm over 1000 cycles (Supplementary Fig. S10). Whereas microcracks may be observed in several regions of the Pt thin film, the CS NF network is well preserved under bending motions for two reasons. First, the strain induced by bending is alleviated by the rearrangement of the nanofibers within the network. Second, the rupturing of the CS NF network under severe bending is avoided due to the small diameters of the flexible PVDF nanofibers12,18.

More systematic bending studies were performed using the three CS NF networks. As shown in Fig. 4a, the R-R0/R0 values of the CS NF networks were measured after 1000 cycles of bending and releasing, gradually reducing the bending radius from 8 to 0.5 mm. R0 and R are the resistances before and after the mechanical durability studies, respectively. During the bending studies, tensile stress was induced in the CS NF network by placing it on the outer surface of a bent PDMS substrate. The tensile strain induced during the bending study may be computed as follows51,63:

Strain=dsubstrate+dnetwork2×Rc, 2

where Rc is the radius of curvature and dsubstrate (= 140 μm) and dnetwork (= 2 μm) are the thicknesses of the PDMS substrate and CS NF network, respectively. The highest strain (14.2%) is induced when Rc=0.5mm. The effect of the bending orientation on ΔR/R0 of the CS NF network was also investigated. The bending orientations of each CS NF network are shown in Fig. 4a. The CS NF network obtained using the rectangular electrode collector exhibits the optimal and worst mechanical durabilities, depending on the bending orientation. When most nanofibers are aligned with the direction of tensile strain (corresponding to “Rectangle–horizontal”), they are subjected to severe strain, resulting in the largest ΔR/R0 (0.304 at Rc=0.5mm). In contrast, when most of the nanofibers are oriented perpendicular to the direction of tensile strain, the smallest ΔR/R0 (0.042 at Rc=0.5mm) is observed. In the case of the CS NF network obtained using the square electrode collector, the ΔR/R0 of “Square–horizontal” (0.128 at Rc=0.5mm) is larger than that of “Square–diagonal” (0.116 at Rc=0.5mm), as approximately half of the nanofibers in the “Square–horizontal” orientation are closely aligned with the direction of tensile strain. Notably, the CS NF networks display excellent mechanical durabilities under repetitive bending with ΔR/R00.304 at Rc=0.5mm, regardless of bending orientation.

Figure 4.

Figure 4

Mechanical durability evaluations of the CS NF networks obtained using the circular, square, and rectangular electrode collectors. (a) ΔR/R0 values of the CS NF networks after 1000 cycles of bending and releasing at various bending radii (the radii of curvature, Rc). The bending directions with respect to the topologies of the nanofiber networks are shown in the schematic diagrams. (b) ΔR/R0 values of the CS NF networks after 10 cycles of stretching and releasing at various strains. The stretching directions with respect to the topologies of the nanofiber networks are shown in the schematic diagrams. (c) Images showing the stretching and releasing of a CS NF network on a PDMS substrate. (d) Schematic diagrams showing the rearrangements of PVDF nanofibers under stretching. The PVDF nanofibers shown in red are highly strained under tensile stress.

To apply the CS NF network in wearable electronic devices, an excellent mechanical durability under stretching is required. Thus, ΔR/R0 was measured after 10 cycles of stretching and releasing (Fig. 4c), and the tensile strain was gradually increased from 10 to 100% (Fig. 4b). Notably, the stretching study was performed in the orientations “Circle–diagonal”, “Square–diagonal”, and “Rectangle–vertical”, as these orientations exhibit superior flexibilities during the bending studies. As shown in the inset of Fig. 4b, the CS NF networks exhibit ΔR/R0<0.55 at strains of ≤ 50%, confirming their excellent stretchabilities. At 10% strain, the largest ΔR/R0 is observed for “Square–diagonal” (0.08), followed by those of “Circle–diagonal” (0.06) and “Rectangle–vertical” (0.02), because of the small R0 of “Square–diagonal” (this is consistent with the results of Rs measurement shown in Fig. 3b). These results display the same trend as that of the results of the bending study shown in Fig. 4a. However, when the strain is > 20%, “Circle–diagonal” exhibits the largest ΔR/R0, and at a strain of 100%, ΔR/R0rectangle=9.93, ΔR/R0square=88.37, and ΔR/R0circle=121.96.

When a CS NF network is subjected to tensile stress, the structure accommodates the resultant strain via topological transition. During the rearrangement of the nanofibers, brittle Pt thin films may maintain their conductivities by forming multiple necks, preventing macroscopic rupture18. When the stretched nanofiber network is subjected to a larger tensile stress, a noticeable increase in resistance occurs, possibly due to the destruction of the fused junctions and the disconnection at the central region of the nanofibers17. The schematic diagrams shown in Fig. 4d display the different rearrangement processes of the nanofibers based on the topology of the nanofiber network. Within “Circle–diagonal”, the rearrangement of the nanofibers is constrained, and several nanofibers (shown in red) closely aligned with the stretching direction should be highly strained. In contrast, in “Square–diagonal” and “Rectangle–vertical”, almost no nanofibers are closely aligned with the stretching directions. Among these three cases, the largest ΔR/R0 of “Circle–diagonal” may be explained by this interpretation. Additionally, for the given stretching motion, the topology of “Rectangle–vertical” is more favorable for the rearrangement of the nanofibers than that of “Square–diagonal”. Therefore, the largest degree of deformation without the destruction of the fused nanofibers should be observed in the topology of “Rectangle–vertical”, followed by those of the topologies of “Square–diagonal” and “Circle–diagonal”. The results of the stretching study shown in Fig. 4b are consistent with this theoretical interpretation. Given the stretchability of the skin (30\%), these CS NF networks exhibit excellent stretchabilities for use in the fields of wearable electronics and soft robotics28.

CS NF networks were also placed on the inner surfaces of the bent PDMS substrates to induce compressive strain, and the ΔR/R0 values measured after 1000 bending cycles at Rc=1mm are shown in Supplementary Fig. S11a. Clearly, ΔR/R0 under compressive strain is much smaller than that under tensile strain (Supplementary Fig. S11b). “Rectangle–horizontal” is the most fragile case under compressive and tensile strains. Finally, to assess the durability of CS NF networks under harsh conditions, ΔR/R0 was monitored during scotch tape peel-off, and sonication tests. The experimental method is introduced in Supplementary Fig. S12. As Supplementary Fig. S12a and d show, there was no considerable increase in ΔR/R0 of the CS NF networks under such harsh conditions.

To assess the performance of the CS NF network as a flexible electrode, a piezoelectric pressure sensor was fabricated (Fig. 1 shows the device structure). It is noted that in the present work the PVDF-Pt CS NF network from the circular electrode collector was used to fabricate a piezoelectric pressure sensor as its Π value was the largest among the three CS NF networks. However, when greater conductivity or stretchability is required, the other CS NF networks may be also applied to the pressure sensor. The piezoelectric composite comprises a PDMS matrix and BTO nanoparticles, which are functionalized using PDA to aid the dispersion of BTO and reduce leakage current during electrical poling64,65. The PDA layer with a thickness of 9nm may be clearly observed in the enlarged TEM image shown in Fig. 5a. The presence of the PDA layer may also be verified using XPS, as shown in Supplementary Fig. S13. The effect of the PDA coating on the electrical properties of the PDMS/BTO@PDA composite was studied by measuring the dielectric permittivity ε of the composite. As shown in Fig. 5b, the ε of the PDMS/BTO composite with a BTO concentration of 20 wt.% decreases with the formation of the PDA layers on the BTO nanoparticles in the frequency range of 103–106 Hz. This is attributed to the decreased interfacial polarization caused by the improved interfacial compatibility between the PDMS matrix and BTO nanoparticles64,65. Due to the reduced interfacial polarization and enhanced dispersion of the BTO nanoparticles, the leakage current density Jl of the PDMS/BTO@PDA composite during electrical poling is considerably decreased by the formation of the PDA layer, as shown in Fig. 5c.

Figure 5.

Figure 5

Characterizations of the BTO@PDA and PDMS/BTO@PDA composites. (a) TEM images of BTO@PDA, including a magnified view of the PDA layer, and the (b) dielectric permittivities ε and (c) leakage current densities Jl of the PDMS/BTO and PDMS/BTO@PDA composites with BTO concentrations of 20 wt.%.

The performance of the piezoelectric pressure sensor with the CS NF network electrodes was evaluated via repetitive pushing and bending studies. In the pushing study (Fig. 6a), the grounded Al tape is attached to the top surface of the pressure sensor to prevent the effect of triboelectricity on the short-circuit current Isc signal66. Figure 6b shows the current density J=Isc/A measured under a pushing force of 20 N at a frequency of 1 Hz. During compression and release of the pushing tip, alternating positive and negative current peaks are produced via the generated piezoelectric potential within the PDMS/BTO@PDA composite67. To validate the origin of the observed current signals, a switching polarity test was performed68,69. Isc was measured in the forward (Fig. 6b) and reverse connection modes (Fig. 6c). In the reverse connection mode, J exhibits approximately the same amplitudes as those observed in the forward connection mode, with the polarities of the signals reversed. Hence, the measured Isc is mainly due to the piezoelectric effect, and the current contributed by other possible artifacts is negligible. Subsequently, the piezoelectric sensor was subjected to basic performance studies. First, J was measured by gradually increasing the pushing force. As shown in Fig. 6d, the peak-to-peak current density (Jpp) steadily increases from 0.20 to 0.63 nA/cm2 with an increase in pushing force from 5 to 20 N. The relationship between Jpp and pushing force is approximately linear, with a sensitivity of 0.029 nA/cm2·N Additionally, the effect of pushing frequency on sensing performance was studied. Figure 6e shows the steady increase of Jpp from 0.27 nA/cm2 to 0.53 nA/cm2 with an increase in pushing frequency from 0.5 to 2.0 Hz. This relationship between the strain rate and Isc is a representative feature of piezoelectric devices, which is well elaborated on in the literature70,71.

Figure 6.

Figure 6

Evaluation of the piezoelectric pressure sensor with the CS NF network electrodes. (a) Image of the pressure sensor under the pushing tester (the grounded Al tape is attached to the top surface of the pressure sensor). J of the pressure sensor was measured during the pushing study in the (b) forward and (c) reverse connection modes. J of the pressure sensor was measured under various pushing (d) forces (5–20 N) and (e) frequencies (0.5–2 Hz). (f) Image of the pressure sensor under the bending tester (Rc indicates the radius of curvature). (g) J of the pressure sensor was measured during the bending study with various radii of curvature (Rc= 1–5 mm).

We also performed bending studies to evaluate the flexibilities of the pressure sensors. As shown in Fig. 6f, the bending radius is precisely controlled to monitor its effect on J. As shown in Fig. 6g, the current signals comprise alternating positive and negative peaks corresponding to the bending and releasing motions of the pressure sensor. As the radius of curvature Rc decreases from 5 to 3 mm, Jpp slowly increases from 0.09 to 0.24 nA/cm2. However, when Rc is reduced to < 3 mm, Jpp increases sharply to 0.57 nA/cm2 Rc=2mm and 0.94 nA/cm2 Rc=1mm. When the pressure sensor is strained via bending, a high piezoelectric potential is formed within the PDMS/BTO@PDA composite, forcing electrons to flow through the external electric circuit. Thus, with a decrease in the bending radius, the strain in the piezoelectric composite intensifies, resulting in an enhanced piezoelectric potential and Jpp. The evaluation results of the piezoelectric pressure sensor indicate that the highly uniform CS NF network was effective to conduct electrical poling for the PDMS/BTO@PDA composite. At the same time, the CS NF network was an effective electrode material for the flexible piezoelectric pressure sensor under mechanical stimuli.

Conclusions

In this study, the topology of the PVDF-Pt CS NF network was engineered to enhance its performance as an FTE. Three distinct topologies of PVDF nanofiber networks were prepared using circular, square, and rectangular electrode collectors during electrospinning. While the CS NF network prepared using the circular electrode collector exhibited an almost isotropic Rs owing to its randomly aligned nanofibers, those obtained using the square and rectangular electrode collectors displayed anisotropic Rs values. The smallest Rs was observed using the CS NF network prepared with the square electrode collector, followed by those of the networks prepared using the circular and rectangular electrode collectors. In contrast, the highest T was observed using the CS NF network prepared using the rectangular electrode collector, followed by those of the networks prepared using the circular and square electrode collectors. The effect of nanofiber alignment on Rs and T was explained using node theory. The actual node density differed from the ideal node density when the network was prepared using the circular electrode collector because of the nanofiber bundles formed. Among the three CS NF networks, that prepared using the circular electrode collector exhibited the largest Π330.5 and smallest n0.026, as it simultaneously displayed a considerably small Rs and high T (e.g., in the CS NF network electrospun for 3 min, Rs=11.29Ω/sq. and T=83.48\% at 550 nm). Meanwhile, the CS NF network obtained using the rectangular electrode collector exhibited superior flexibilities in certain strain directions compared to those of the networks prepared using the circular and square electrode collectors. This suggested that the flexibility depended on the Kirigami design of the nanofiber network. In randomly aligned nanofiber networks, several nanofibers were always closely aligned with the directions of strain induced by bending and stretching, resulting in the destruction of the nanofibers. However, in the CS NF network prepared using the rectangular electrode collector, the strain was accommodated by the rearrangement of the nanofibers. Piezoelectric pressure sensors based on PDMS/BTO@PDA piezoelectric layers were fabricated using the prepared CS NF networks as the top and bottom electrodes. In this process, the CS NF networks were used as the conductive materials during the electrical poling process of the piezoelectric composite layer. The highly uniform nanofiber network was advantageous to conduct electrical poling for the piezoelectric composite layer. The dependencies of Isc on the pushing force and frequency, and bending radius, were evaluated via pushing and bending studies. This study reveals the competitiveness of the PVDF-Pt CS NF network as an electrode for use in flexible electronic devices.

Supplementary Information

Acknowledgements

This work was supported by the National Research Foundation of Korea (NRF) grant funded by the Korea government(MSIT) (No. 2022R1F1A107172011).

Author contributions

The role of each author in the manuscript is shown as follows: H.P. contributed conceptualization, data curation, formal analysis, investigation, methodology, project administration, validation, visualization, writing—original draft, review & editing; H.S. contributed investigation, writing—original draft; J.G. contributed formal analysis, investigation, validation, visualization; D.L. contributed methodology, investigation; D.P. contributed methodology, investigation; Y.L. contributed conceptualization; K.K. contributed conceptualization, funding acquisition, methodology, project administration, resources, supervision, visualization, writing—original draft, review & editing;

Data availability

The datasets generated during and/or analysed during the current study are available from the corresponding author on reasonable request.

Competing interests

The authors declare no competing interests.

Footnotes

Publisher's note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Supplementary Information

The online version contains supplementary material available at 10.1038/s41598-023-29812-5.

References

  • 1.Li D, Lai WY, Zhang YZ, Huang W. Printable transparent conductive films for flexible electronics. Adv. Mater. 2018;30:1704738. doi: 10.1002/adma.201704738. [DOI] [PubMed] [Google Scholar]
  • 2.Chen ZH, Fang R, Li W, Guan J. Stretchable transparent conductors: From micro/macromechanics to applications. Adv. Mater. 2019;31:1900756. doi: 10.1002/adma.201900756. [DOI] [PubMed] [Google Scholar]
  • 3.Granqvist CG, Hultåker A. Transparent and conducting ITO films: New developments and applications. Thin Solid Films. 2002;411:1–5. doi: 10.1016/S0040-6090(02)00163-3. [DOI] [Google Scholar]
  • 4.Li X, et al. Transfer of large-area graphene films for high-performance transparent conductive electrodes. Nano Lett. 2009;9:4359–4363. doi: 10.1021/nl902623y. [DOI] [PubMed] [Google Scholar]
  • 5.Chen Z, Cotterell B, Wang W, Guenther E, Chua SJ. A mechanical assessment of flexible optoelectronic devices. Thin Solid Films. 2001;394:202–206. doi: 10.1016/S0040-6090(01)01138-5. [DOI] [Google Scholar]
  • 6.Hecht DS, Hu L, Irvin G. Emerging transparent electrodes based on thin films of carbon nanotubes, graphene, and metallic nanostructures. Adv. Mater. 2011;23:1482–1513. doi: 10.1002/adma.201003188. [DOI] [PubMed] [Google Scholar]
  • 7.De S, King PJ, Lyons PE, Khan U, Coleman JN. Size effects and the problem with percolation in nanostructured transparent conductors. ACS Nano. 2010;4:7064–7072. doi: 10.1021/nn1025803. [DOI] [PubMed] [Google Scholar]
  • 8.De S, Coleman JN. The effects of percolation in nanostructured transparent conductors. MRS Bull. 2011;36:774–781. doi: 10.1557/mrs.2011.236. [DOI] [PubMed] [Google Scholar]
  • 9.Lee J, et al. Very long Ag nanowire synthesis and its application in a highly transparent, conductive and flexible metal electrode touch panel. Nanoscale. 2012;4:6408–6414. doi: 10.1039/c2nr31254a. [DOI] [PubMed] [Google Scholar]
  • 10.Scardaci V, Coull R, Lyons PE, Rickard D, Coleman JN. Spray deposition of highly transparent, low-resistance networks of silver nanowires over large areas. Small. 2011;7:2621–2628. doi: 10.1002/smll.201100647. [DOI] [PubMed] [Google Scholar]
  • 11.Li D, Xia Y. Electrospinning of nanofibers: Reinventing the wheel? Adv. Mater. 2004;16:1151–1170. doi: 10.1002/adma.200400719. [DOI] [Google Scholar]
  • 12.Wu H, et al. Electrospun metal nanofiber webs as high-performance transparent electrode. Nano Lett. 2010;10:4242–4248. doi: 10.1021/nl102725k. [DOI] [PubMed] [Google Scholar]
  • 13.Hsu PC, et al. Passivation coating on electrospun copper nanofibers for stable transparent electrodes. ACS Nano. 2012;6:5150–5156. doi: 10.1021/nn300844g. [DOI] [PubMed] [Google Scholar]
  • 14.Kim GH, Shin JH, An T, Lim G. Junction-free flat copper nanofiber network-based transparent heater with high transparency, high conductivity, and high temperature. Sci. Rep. 2018;8:13581. doi: 10.1038/s41598-018-32045-6. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 15.Wu H, et al. A transparent electrode based on a metal nanotrough network. Nat. Nanotechnol. 2013;8:421–425. doi: 10.1038/NNANO.2013.84. [DOI] [PubMed] [Google Scholar]
  • 16.An BW, et al. Stretchable and transparent electrodes using hybrid structures of graphene-metal nanotrough networks with high performances and ultimate uniformity. Nano Lett. 2014;14:6322–6328. doi: 10.1021/nl502755y. [DOI] [PubMed] [Google Scholar]
  • 17.An BW, et al. Stretchable, transparent electrodes as wearable heaters using nanotrough networks of metallic glasses with superior mechanical properties and thermal stability. Nano Lett. 2016;16:471–478. doi: 10.1021/acs.nanolett.5b04134. [DOI] [PubMed] [Google Scholar]
  • 18.Soltanian S, et al. Highly stretchable, sparse, metallized nanofiber webs as thin, transferrable transparent conductors. Adv. Energy Mater. 2013;3:1332–1337. doi: 10.1002/aenm.201300193. [DOI] [Google Scholar]
  • 19.Fuh YK, Lien LC. Pattern transfer of aligned metal nano/microwires as flexible transparent electrodes using an electrospun nanofiber template. Nanotechnology. 2013;24:055301. doi: 10.1088/0957-4484/24/5/055301. [DOI] [PubMed] [Google Scholar]
  • 20.Song R, et al. An ultra-long and low junction-resistance Ag transparent electrode by electrospun nanofibers. RSC Adv. 2016;6:91641–91648. doi: 10.1039/c6ra19131b. [DOI] [Google Scholar]
  • 21.Singh SB, Hu Y, Kshetri T, Kim NH, Lee JH. An embedded-PVA@Ag nanofiber network for ultra-smooth, high performance transparent conducting electrodes. J. Mater. Chem. C. 2017;5:4198–4205. doi: 10.1039/c7tc01002h. [DOI] [Google Scholar]
  • 22.Huh JW, Jeon HJ, Ahn CW. Flexible transparent electrodes made of core-shell-structured carbon/metal hybrid nanofiber mesh films fabricated via electrospinning and electroplating. Curr. Appl. Phys. 2017;17:1401–1408. doi: 10.1016/j.cap.2017.07.016. [DOI] [Google Scholar]
  • 23.Singh SB, Singh TI, Kim NH, Lee JH. A core-shell MnO2@Au nanofiber network as a high-performance flexible transparent supercapacitor electrode. J. Mater. Chem. A. 2019;7:10672–10683. doi: 10.1039/c9ta00778d. [DOI] [Google Scholar]
  • 24.Kim GH, Woo H, Kim S, An T, Lim G. Highly-robust, solution-processed flexible transparent electrodes with a junction-free electrospun nanofiber network. RSC Adv. 2020;10:9940–9948. doi: 10.1039/c9ra10278g. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 25.Li T, Suo Z. Deformability of thin metal films on elastomer substrates. Int. J. Solids Struct. 2006;43:2351–2363. doi: 10.1016/j.ijsolstr.2005.04.034. [DOI] [Google Scholar]
  • 26.Lacour SP, Chan D, Wagner S, Li T, Suo Z. Mechanisms of reversible stretchability of thin metal films on elastomeric substrates. Appl. Phys. Lett. 2006;88:204103. doi: 10.1063/1.2201874. [DOI] [Google Scholar]
  • 27.Huang S, Liu Y, Zhao Y, Ren Z, Guo CF. Flexible electronics: stretchable electrodes and their future. Adv. Funct. Mater. 2019;29:1805924. doi: 10.1002/adfm.201805924. [DOI] [Google Scholar]
  • 28.Matsuhisa N, Chen X, Bao Z, Someya T. Materials and structural designs of stretchable conductors. Chem. Soc. Rev. 2019;48:2946–2966. doi: 10.1039/c8cs00814k. [DOI] [PubMed] [Google Scholar]
  • 29.Huang S, Liu Y, Guo CF, Ren Z. A highly stretchable and fatigue-free transparent electrode based on an in-plane buckled Au nanotrough network. Adv. Electron. Mater. 2017;3:1600534. doi: 10.1002/aelm.201600534. [DOI] [Google Scholar]
  • 30.Jin Y, et al. Buckled Au@PVP nanofiber networks for highly transparent and stretchable conductors. Adv. Electron. Mater. 2016;2:1500302. doi: 10.1002/aelm.201500302. [DOI] [Google Scholar]
  • 31.Guo CF, et al. Fatigue-free, superstretchable, transparent, and biocompatible metal electrodes. Proc. Natl. Acad. Sci. U. S. A. 2015;112:12332–12337. doi: 10.1073/pnas.1516873112. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 32.Li D, Wang Y, Xia Y. Electrospinning of polymeric and ceramic nanofibers as uniaxially aligned arrays. Nano Lett. 2003;3:1167–1171. doi: 10.1021/nl0344256. [DOI] [Google Scholar]
  • 33.Li D, Wang Y, Xia Y. Electrospinning nanofibers as uniaxially aligned arrays and layer-by-layer stacked films. Adv. Mater. 2004;16:361–366. doi: 10.1002/adma.200306226. [DOI] [Google Scholar]
  • 34.Li D, Ouyang G, McCann JT, Xia Y. Collecting electrospun nanofibers with patterned electrodes. Nano Lett. 2005;5:913–916. doi: 10.1021/nl0504235. [DOI] [PubMed] [Google Scholar]
  • 35.Trung TQ, Lee NE. Materials and devices for transparent stretchable electronics. J. Mater. Chem. C. 2017;5:2202–2222. doi: 10.1039/c6tc05346g. [DOI] [Google Scholar]
  • 36.Lee Y, et al. Graphene-based stretchable/wearable self-powered touch sensor. Nano Energy. 2019;62:259–267. doi: 10.1016/j.nanoen.2019.05.039. [DOI] [Google Scholar]
  • 37.Chang C, Tran VH, Wang J, Fuh YK, Lin L. Direct-write piezoelectric polymeric nanogenerator with high energy conversion efficiency. Nano Lett. 2010;10:726–731. doi: 10.1021/nl9040719. [DOI] [PubMed] [Google Scholar]
  • 38.Kang DH, Kang HW. Advanced electrospinning using circle electrodes for freestanding PVDF nanofiber film fabrication. Appl. Surf. Sci. 2018;455:251–257. doi: 10.1016/j.apsusc.2018.05.211. [DOI] [Google Scholar]
  • 39.Hartley, F. R. et al. Chemistry of the platinum group metals: recent developments (ed. Hartley, F. R.) 20 (Elsevier, 1991).
  • 40.Jia N, et al. Enhanced β-crystalline phase in poly(vinylidene fluoride) films by polydopamine-coated BaTiO3 nanoparticles. Mater. Lett. 2015;139:212–215. doi: 10.1016/j.matlet.2014.10.069. [DOI] [Google Scholar]
  • 41.Hanani Z, et al. Lead-free nanocomposite piezoelectric nanogenerator film for biomechanical energy harvesting. Nano Energy. 2021;81:105661. doi: 10.1016/j.nanoen.2020.105661. [DOI] [Google Scholar]
  • 42.Sunkara V, Park DK, Cho YK. Versatile method for bonding hard and soft materials. RSC Adv. 2012;2:9066–9070. doi: 10.1039/c2ra20880f. [DOI] [Google Scholar]
  • 43.Yang Y, Kim K. Simultaneous acquisition of current and lateral force signals during AFM for characterising the piezoelectric and triboelectric effects of ZnO nanorods. Sci. Rep. 2021;11:2904. doi: 10.1038/s41598-021-82506-8. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 44.Rezakhaniha R, et al. Experimental investigation of collagen waviness and orientation in the arterial adventitia using confocal laser scanning microscopy. Biomech. Model. Mechanobiol. 2012;11:461–473. doi: 10.1007/s10237-011-0325-z. [DOI] [PubMed] [Google Scholar]
  • 45.Morrill EE, et al. A validated software application to measure fiber organization in soft tissue. Biomech. Model. Mechanobiol. 2016;15:1467–1478. doi: 10.1007/s10237-016-0776-3. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 46.Dorati R, et al. The effect of process parameters on alignment of tubular electrospun nanofibers for tissue regeneration purposes. J. Drug Deliv. Sci. Technol. 2020;58:101781. doi: 10.1016/j.jddst.2020.101781. [DOI] [Google Scholar]
  • 47.Poddar S, et al. Fabrication and characterization of electrospun psyllium husk-based nanofibers for tissue regeneration. J. Appl. Polym. Sci. 2021;138:50569. doi: 10.1002/app.50569. [DOI] [Google Scholar]
  • 48.Marques-Moros F, Forment-Aliaga A, Pinilla-Cienfuegos E, Canet-Ferrer J. Mirror effect in atomic force microscopy profiles enables tip reconstruction. Sci. Rep. 2020;10:18911. doi: 10.1038/s41598-020-75785-0. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 49.Martnez L, et al. Aspect-ratio and lateral-resolution enhancement in force microscopy by attaching nanoclusters generated by an ion cluster source at the end of a silicon tip. Rev. Sci. Instrum. 2011;82:023710. doi: 10.1063/1.3556788. [DOI] [PubMed] [Google Scholar]
  • 50.Chen Z, Luo J, Doudevski I, Erten S, Kim SH. Atomic force microscopy (AFM) analysis of an object larger and sharper than the AFM Tip. Microsc. Microanal. 2019;25:1106–1111. doi: 10.1017/S1431927619014697. [DOI] [PubMed] [Google Scholar]
  • 51.Choi J, et al. Junction-free electrospun Ag fiber electrodes for flexible organic light-emitting diodes. Small. 2018;14:1702567. doi: 10.1002/smll.201702567. [DOI] [PubMed] [Google Scholar]
  • 52.Hwang BY, Choi SH, Lee KW, Kim JY. Highly stretchable and transparent electrode film based on SWCNT/Silver nanowire hybrid nanocomposite. Compos. B. Eng. 2018;151:1–7. doi: 10.1016/j.compositesb.2018.06.004. [DOI] [Google Scholar]
  • 53.Lee EJ, Kim YH, Hwang DK, Choi WK, Kim JY. Synthesis and optoelectronic characteristics of 20 nm diameter silver nanowires for highly transparent electrode films. RSC Adv. 2016;6:11702–11710. doi: 10.1039/c5ra25310a. [DOI] [Google Scholar]
  • 54.De S, et al. Silver nanowire networks as flexible, transparent, conducting films: extremely high DC to optical conductivity ratios. ACS Nano. 2009;3:1767–1774. doi: 10.1021/nn900348c. [DOI] [PubMed] [Google Scholar]
  • 55.De S, et al. Flexible, transparent, conducting films of randomly stacked graphene from surfactant-stabilized, oxide-free graphene dispersions. Small. 2010;6:458–464. doi: 10.1002/smll.200901162. [DOI] [PubMed] [Google Scholar]
  • 56.Sepulveda-Mora SB, Cloutier SG. Figures of merit for high-performance transparent electrodes using dip-coated silver nanowire networks. J. Nanomater. 2012;2012:4. doi: 10.1155/2012/286104. [DOI] [Google Scholar]
  • 57.Kwon YT, et al. Novel concept for fabricating a flexible transparent electrode using the simple and scalable self-assembly of Ag nanowires. J. Phys. Chem. C. 2017;121:5740–5746. doi: 10.1021/acs.jpcc.7b00148. [DOI] [Google Scholar]
  • 58.Han B, et al. Uniform self-forming metallic network as a high-performance transparent conductive electrode. Adv. Mater. 2014;26:873–877. doi: 10.1002/adma.201302950. [DOI] [PubMed] [Google Scholar]
  • 59.Kwon NY, et al. Uniform silver nanowire patterned electrode on robust PEN substrate using poly(2-hydroxyethyl methacrylate) underlayer. ACS Appl. Mater. Interfaces. 2022;14:34909–34917. doi: 10.1021/acsami.2c07063. [DOI] [PubMed] [Google Scholar]
  • 60.Feng X, et al. Cost-effective fabrication of uniformly aligned silver nanowire microgrid-based transparent electrodes with higher than 99% transmittance. ACS Appl. Mater. Interfaces. 2022;14:39199–39210. doi: 10.1021/acsami.2c09672. [DOI] [PubMed] [Google Scholar]
  • 61.Miao L, Liu G, McEleney K, Wang J. Epoxy-embedded silver nanowire meshes for transparent flexible electrodes. J. Mater. Sci. 2019;54:10355–10370. doi: 10.1007/s10853-019-03507-7. [DOI] [Google Scholar]
  • 62.Jiang DH, et al. Facile preparation of Cu/Ag core/shell electrospun nanofibers as highly stable and flexible transparent conductive electrodes for optoelectronic devices. ACS Appl. Mater. Interfaces. 2019;11:10118–10127. doi: 10.1021/acsami.8b18366. [DOI] [PubMed] [Google Scholar]
  • 63.Lee KJ, et al. A printable form of single-crystalline gallium nitride for flexible optoelectronic systems. Small. 2005;1:1164–1168. doi: 10.1002/smll.200500166. [DOI] [PubMed] [Google Scholar]
  • 64.Xie Y, Yu Y, Feng Y, Jiang W, Zhang Z. Fabrication of stretchable nanocomposites with high energy density and low loss from cross-linked PVDF filled with poly(dopamine) encapsulated BaTiO3. ACS Appl. Mater. Interfaces. 2017;9:2995–3005. doi: 10.1021/acsami.6b14166. [DOI] [PubMed] [Google Scholar]
  • 65.Yang Y, et al. Flexible piezoelectric pressure sensor based on polydopamine-modified BaTiO3/PVDF composite film for human motion monitoring. Sens. Actuators A Phys. 2020;301:111789. doi: 10.1016/j.sna.2019.111789. [DOI] [Google Scholar]
  • 66.Šutka A, et al. Measuring piezoelectric output—fact or friction? Adv. Mater. 2020;32:2002979. doi: 10.1002/adma.202002979. [DOI] [PubMed] [Google Scholar]
  • 67.Park D, Kim K. Rational design of PVDF/BaTiO3 nanoparticle/Cu nanowire ternary nanocomposite films for optimal piezoelectric power generation. J. Appl. Phys. 2021;130:204101. doi: 10.1063/5.0064129. [DOI] [Google Scholar]
  • 68.Shin SH, Kim YH, Lee MH, Jung JY, Nah J. Hemispherically aggregated BaTiO3 nanoparticle composite thin film for high-performance flexible piezoelectric nanogenerator. ACS Nano. 2014;8:2766–2773. doi: 10.1021/nn406481k. [DOI] [PubMed] [Google Scholar]
  • 69.Zheng Q, et al. High-performance flexible piezoelectric nanogenerators consisting of porous cellulose nanofibril (CNF)/poly(dimethylsiloxane) (PDMS) aerogel films. Nano Energy. 2016;26:504–512. doi: 10.1016/j.nanoen.2016.06.009. [DOI] [Google Scholar]
  • 70.Briscoe J, et al. Measurement techniques for piezoelectric nanogenerators. Energy Environ. Sci. 2013;6:3035–3045. doi: 10.1039/c3ee41889h. [DOI] [Google Scholar]
  • 71.Zhang G, et al. A rationally designed output current measurement procedure and comprehensive understanding of the output characteristics for piezoelectric nanogenerators. Nano Energy. 2016;30:180–186. doi: 10.1016/j.nanoen.2016.10.004. [DOI] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

Data Availability Statement

The datasets generated during and/or analysed during the current study are available from the corresponding author on reasonable request.


Articles from Scientific Reports are provided here courtesy of Nature Publishing Group

RESOURCES