Abstract
Hydrogen peroxide (H2O2) and glucose play a key role in many cellular signaling pathways. The efficient and accurate in situ detection of H2O2 released from living cells has attracted extensive research interests. Herein, a new porphyrin-based porous covalent organic framework (TAP-COF) was fabricated via one-step condensation of 1,6,7,12-tetrachloroperylene tetracarboxylic acid dianhydride and 5,10,15,20-tetrakis (4-aminophenyl)porphyrin iron(III). The obtained TAP-COF has high surface areas, abundant surface catalytic active sites, and highly effective electron transport due to its precisely controllable donor–acceptor arrangement and 3D porous structure. Then, the new TAP-COF exhibited excellent peroxidase-like catalytic activity, which could effectively catalyze oxidation of the substrate 3,3′,5,5′-tetramethylbenzidine by H2O2 to produce a typical blue-colored reaction. On this basis, simple, rapid and selective colorimetric methods for in situ H2O2 detection were developed with the detection limit of 2.6 nM in the wide range of 0.01 to 200 μM. The colorimetric approach also could be used for in situ detection of H2O2 released from living MCF-7 cells. This portable sensor based on a COF nanozyme not only opens a new path for point-of-care testing, but also has potential applications in the field of cell biology and clinical diagnosis.
Keywords: porphyrin, covalent organic framework, peroxidase-like activity, cells, H2O2
1. Introduction
Small molecule biomarkers are a significant part of sustaining life processes and biological metabolism [1]. Among them, hydrogen peroxide (H2O2), one of the frequent reactive oxygen species in biological systems, is essential for promoting cellular proliferation, differentiation, and emigration [2,3]. Various illnesses including cancer [4], diabetes mellitus [5], neurological disorders [6], and angiocardiopathy [7] are tightly accompanied by abnormal H2O2 production. For example, cancer cells have considerably greater amounts of H2O2 (6.0 μM–1.2 mM) than normal cells (less than 0.72 μM) [8]. Therefore, the need for a reliable and accurate approach for the extremely hypersensitive identification of H2O2 in living creatures is critical. The examination of H2O2 has been reported using a variety of strategies, including electrochemical [9], fluorescence [10,11], electrochemiluminescence [12], spectrophotometry [13], etc., among which colorimetric tests [14] are considered to be an effective and straightforward method due to its affordability and usefulness.
Peroxidases, like horseradish peroxidase (HRP) and thyroid peroxidase, are found in plankton and flora and fauna, which are commonly utilized because of their high particularity and effectiveness under mild settings [15]. However, due to their inherent nature as proteins, the majority of natural enzymes have many inevitable shortcomings, such as intrinsic instability, costly preparation, and easy denaturation under adverse conditions, which severely restricts their real applications [16]. Then, a lot of work has been put into researching nanozymes, such as porphyrins and metal complexes, with the aim of simulating the structures and activities of naturally produced enzymes. Due to their affordability, a large-scale production capacity, superior stability and robustness compared to natural enzymes, the interests in nanozymes with unexpected enzyme-like activity have grown recently.
Porphyrin-based nanozymes are currently receiving more focus for their biological similarity to inartificial enzymes like cytochrome P450 and hemoglobin [17]. Various iron porphyrins, including hemin [18] and 5,10,15,20-tetrakis-(4′-bromophenyl)porphyrinato iron(III) [19] are used to simulate HRP activity. Free iron porphyrins cannot, however, be used in standard immunoassay platforms because of their poorer imitation of peroxidase activity and facile aggregation property [20]. Recently, a lot of interest has been focused on porphyrin-based covalent organic frameworks (COFs), which are produced from porphyrin or metalloporphyrin through strong covalent bonding, as biomimetic catalysts, electrocatalysts, and photocatalysts [21,22,23] due to their superior catalytic operations and close biological affinity to inartificial enzymes. These possess COFs’ intrinsic benefits, including their high surface area, tunable pore topologies, functionalization, and excellent thermal and chemical durability. By incorporating metalloporphyrin into COFs, high density active sites would be added to the skeleton of the COFs, and the catalytic deactivation brought on by porphyrin aggregation might also be prevented. Typically, Song’s group proposed a series of ultrastable iron porphyrin-based COFs with 3D channels as biomimetic catalysts [24]. Lin’s group created a 3D porphyrin-based COFs through the co-condensation of tetrahedrons with parallelogram construction blocks to enhance catalytic performance [25]. Additionally, to produce small band gaps for the dissociation and transportation of electron-hole pairs, the appropriate combination and arrangement of complementary donor–acceptor pairs inside the COFs skeleton have been shown to be an effective strategy to generate higher catalytic activity. Meanwhile, the unitarity of the COFs would be advantageous to boost the efficiency of enzymatic processes by improving the stable enzymes and decreasing the diffusion barrier.
Inspired by the above discussion, a donor–acceptor COFs (defined as TAP-COF) with 5,10,15,20-tetrakis (4-aminophenyl)porphyrine iron(III) chloride (FeTAPP) as the donor and 1,6,7,12-tetrachloroperylene tetracarboxylic acid dianhydride (TAD) as the acceptor was synthesized and employed as a peroxidase-mimicking nanozyme. The produced D-A COFs had a high degree of crystallinity, a sizable amount of porosity, excellent electron transport, and a significant number of catalytic active sites. Moreover, TAP-COF was a metalloporphyrin-based COFs with a built-in catalyst that could successfully prevent deactivation, which was frequently linked to porphyrin aggregation. TAP-COF was utilized to build a colorimetric assay in viable cells for in situ analysis of H2O2 using of 3,3′,5,5′-tetramethylbenzidine (TMB), which offered a novel method of cell monitoring and has promising uses in the field of fast clinical detection.
2. Materials and Methods
2.1. Peroxidase-like Performance of TAP-COF
By catalytically oxidizing the peroxidase zymolyte TMB in the absence of H2O2, the peroxidase-like activity of TAP-COF was examined. The measurements were made by monitoring the absorbance information in time-scan patterns at 652 nm. In the typical experiment, 200 μL 0.32 mg·mL−1 TAP-COF dispersed in water, 200 μL H2O2 (30 mM), and 200 μL TMB (0.80 mM) as the substrate were added to a HAc–NaAc buffer solution (pH 3.8).
In a typical colorimetric experiment, 200 μL TAP-COF (0.32 mg·mL−1) dispersed in water, 200 μL H2O2 (30 mM), and 200 μL tert-butyl alcohol (1 mM) were added into 1200 μL of a HAc–NaAc buffer solution (pH 3.8). Next, the above solution was incubated at 25 °C for 0.5 h and 200 µL TMB (0.80 mM) was added before incubating for another 10 min. Subsequently, UV–vis absorption spectroscopies were used to gauge the final reaction solution. In comparison, the same experimental conditions were used to investigate the expression system of TAP-COF + H2O2 + TMB + buffer by omitting the tert-butyl alcohol.
2.2. Condition Optimization
The influences of the pH values (1.7–8.0), temperatures (25–70 °C), and various concentrations of H2O2 (1–400 mM) and TMB (0.20–2.5 mM) were investigated to evaluate the peroxidase-like activity of the TAP-COF composites. The effect of the catalyst amount was also studied.
2.3. Detection of H2O2 in Cells
A total of 200 μL phorbol 12-myristate-13-acetate (PMA) (50 g·mL−1) was injected to a counting plate containing 0, 100, 200, 500, 1000, 3000, or 5000 cells·mL−1 MCF-7 cells in order to determine the amount of H2O2 released by the cells. To facilitate color development, 200 μL TMB (0.8 mM) and 200 μL TAP-COF (0.32 mg·mL−1) were injected to each counting plate after the specimens had been incubated for 10 min in 0.2 M HAc–NaAc (pH 4.0). A microplate reader was used to measure each well’s absorbance at 652 nm, which was believed to be related to the emission of H2O2 in cells.
3. Results and Discussions
3.1. Structure and Morphology Characterization
TAP-COF was synthesized by condensation between FeTAPP with TAD in the presence of 4 Å molecular sieves under solvothermal conditions (Scheme 1). To confirm the formation of the diimide linkages between FeTAPP and TAD units in the TAP-COF, Fourier transform infrared (FT-IR) spectroscopy was performed (Figure 1A). FT-IR spectra indicated that the peak of the N-H stretching of -NH2 (at 3364 cm−1) from FeTAPP disappeared after polymerization. Meanwhile, the C = O amide stretching vibrations correspond to the absorptions at 1666 cm−1. The peak at 1323 cm−1 was attributed to the C-H in phenyl rings’ in-plane bending vibration. In addition, with the presence of C-N-C, a clear band was displayed at 1594 cm−1 [26]. However, the peaks belonging to anhydride were not accurately identified due to the synthesis of imide between amino groups and anhydride. The X-ray diffraction (XRD) measurement indicated that TAP-COF was a well crystalline material as illustrated in Figure 1B. The XRD diagram of TAP-COF demonstrated two peaks at 1.26 nm and 0.72 nm, which were ascribed to diffraction from the (200) and (002) planes, respectively. In addition, the XRD pattern also displayed three higher order refractions at 0.88, 0.42, and 0.38 nm, which were ascribed to diffraction from the (300), (600), and (800) planes, respectively, revealing the high molecular ordering nature of this COF along the a-axis of the unit cell [27]. The (001) plane gave its higher order diffractions at 0.34 nm in the wide-angle range of the XRD pattern. These diffraction results could be assigned to refraction from a rectangular lattice with the cell parameter of a = 2.52 nm, b = 2.52 nm, and c = 1.44 nm (Figure S1 in Supplementary Materials). In addition, the XRD pattern of TAP-COF exhibited additional refraction at 0.34 nm, which was attributed to the π-π stacking distance between (100) planes [28,29,30].
The morphologies of TAP-COF were analyzed using scanning electron microscopy (SEM). The SEM image (Figure 1C) revealed that TAP-COF had a distinct lamellar structure. In addition, the energy-dispersive spectrometry mapping was exhibited in Figure 1D. Atoms of the expected composition (N, O, Cl, Fe) of the compound could be detected, suggesting that TAP-COF was synthesized successfully. In order to further investigate the morphology of TAP-COF, high-resolution transmission electron microscopy (HRTEM) was also performed. The sample’s crystalline nature was confirmed by the regular spot pattern that was revealed by the selected area electron diffraction (SAED) in the chosen location, as exhibited in Figure 1E. The HRTEM image indicated that the lattice space of the TAP-COF was calculated to be 0.42 nm (Figure 1F), which corresponded to (600) plane of TAP-COF as seen in the XRD profile.
To further confirm the thermal stability of TAP-COF, thermal gravimetric analysis (TGA) under air conditions of the sample was conducted. As illustrated in Figure S2, the TGA presented a rapid weight loss of ~12.2% in the temperature range of 25–150 °C, which seemed to be ascribed to the loss of the solvent absorbed in the porous sample [31]. Then, the TGA profile of the TAP-COF did not exhibit any weight loss in the temperature range of 150–380 °C. In addition, TAP-COF showed an observable weight loss over 380 °C, which was attributed to the decomposition of the frameworks. Based on the above analysis, the TGA curves revealed that the TAP-COF was thermally stable up to 380 °C.
The permanent porosity of TAP-COF was checked by N2 adsorption isotherms collected at 77 K (Figure S3). The sorption isotherm fit well with the type IV characters, suggesting the permanent mesoporous nature of TAP-COF. According to the Figure S3, the COF had a total pore volume of 0.124 cm3·g−1 (P/P0 = 0.99). In addition, the BET and Langmuir surface areas of TAP-COF were calculated to be 66.38 and 140.12 m2·g−1, respectively, which indicated the small surface area of TAP-COF compared to other COFs. It might be related to the disorganized stacking of the TAP-COF layers caused by the steric hindrance of TAD and the twisting configuration of the phenyl units in FeTAPP.
3.2. Peroxidase-like Activity of TAP-COF
The peroxide simulation properties of TAP-COF were examined by oxidizing the colorimetric primer TMB to oxTMB, which could be easily monitored by the UV–vis absorbance spectroscopy or observed by the naked eyes. Figure 2A shows the UV–vis absorption spectra for the different test solutions. The absence experiments were performed to determine the components needed to trigger the reaction. When both TAP-COF and H2O2 were present in the reaction system, there was a higher absorption peak at 652 nm, indicating that TAP-COF and H2O2 were required for the catalytic process. Additionally, Figure 2B shows the variations of absorbance over time for TAP-COF + H2O2 + TMB and H2O2 + TMB + FeTAPP. The absorbance at 652 nm rose for each system as the reaction proceeded, but the TAP-COF + H2O2 + TMB system responded much more quickly than the other systems. After only five minutes of reaction, the absorbance of TAP-COF + H2O2 + TMB exceeded that of FeTAPP + H2O2 + TMB, indicating that TAP-COF had a greater catalytic activity than FeTAPP. These findings unequivocally indicated that TAP-COF had a better sensitivity for accelerating the oxidation of TMB. The inherent skeleton structure, high N content, and D-A structure of TAP-COF might be the origin of its porosity characteristics, electron cloud density, and greater surface catalytic activity sites. These would hasten the electron exchange between reactive oxygen species generated by catalyzing hydrogen peroxide decomposition and TMB, thus increasing the catalytic activity. They also had electrostatic interaction that bind the catalytically active sites of TAP-COF to the positively charged TMB.
3.3. Optimization of Experimental Conditions
Similar to HRP and other nanomaterial-based peroxidase mimics, the pH, temperature, and substrate concentration during the color development process also influenced the catalytic performance of TAP-COF. Then, the peroxidase-like activity of TAP-COF was investigated by varying the pH (1.7–8), temperature (25–70 °C), H2O2 concentration (0–200 M), and TMB concentration (0.2–2.5 mM) as shown in Figure S4. These data suggested that the ideal experimental settings were pH 3.8, 25 °C, the relative lowest necessary concentration of H2O2 (200 μM) and 0.8 nM of TMB. Moreover, the catalytic activity of TAP-COF was also related to its amount. The catalytic activity increased with a rapid increase in catalyst concentration from 0 to 1.0 mg·mL−1 and then there was a downtrend from 1.0 to 1.5 mg·mL−1. Thus, the optimal concentration of TAP-COF was chosen as 1.0 mg·mL−1.
3.4. Steady-State Kinetic Analysis
Typical Michaelis–Menten curves were produced under ideal conditions over a range of TMB or H2O2 concentrations to quantitatively explore the catalytic activities of the TAP-COF (Figure S5). Under the guidance of the Lineweaver–Burk equation, the Michaelis constant (Km) and the maximum response velocity (Vmax) were calculated (Table 1). In general, Km describes how well an enzyme binds to its substrates, with a lower Km value indicating a stronger binding. The Km of TAP-COF (0.78 mM) for H2O2 as primer was significantly lower than that of HRP (3.7 mM), demonstrating that the affinity of TAP-COF for H2O2 was stronger than that of HRP. This might be because of the increased electrostatic contact between TMB and TAP-COF produced by its high N content. Furthermore, the TAP-COF had a Km of 0.18 mM with TMB as the substrate, which was lower than the HRP’s Km of 0.43 mM, indicating that TAP-COF also had a high affinity for the TMB mediator. These results implied that TAP-COF had promising peroxidase-like activity, which was in line with other discoveries using various peroxidase mimics based on nanomaterials (Table 1).
Table 1.
3.5. Colorimetric Sensing
The catalysis-based colorimetric test revealed extremely sensitive changes in absorption with varying H2O2 concentrations. Figure 3A demonstrates that the immunoassay solutions gradually darkened from colorless to blue as the H2O2 content increased. Additionally, Figure 3B and C illustrates a superb linear correlation between the logarithm of H2O2 concentration in the range of 0.01 μM to 200 μM and the absorbance of oxidized TMB at 652 nm. The TAP-COF-based sensor had a lower limit of detection (LOD) and larger linear range compared to other previously published outstanding peroxidase-based sensors (see Table S1). Additionally, our proposed sensor’s LOD was lower than that of some of the other electrochemical and fluorescent sensors, which might be explained by the fact that the interlinking of electron acceptor and donor of TAP-COF could improve the electron transport rate, as well as allow exposure to high concentrations of catalytic active sites, thus contributing to its increased catalytic activity.
Moreover, H2O2 was also a major byproduct of other metabolic processes, including the oxidation of uric acid by the enzyme uricase as well as the oxidation of glucose by the enzyme glucose oxidase (GOD). Consequently, the measurement of H2O2 might be used to indirectly infer the quantities of living components. Figure 4A displays the TMB + TAP-COF + GOD photographs at various glucose concentrations. As the glucose concentration increased linearly, the reaction became progressively darker blue in the presence of TAP-COF and GOD. The standard curves for these reactions are shown in Figure 4C, where the linear range of glucose was 0.3–800 μM, and the LOD was 0.14 μM, which was comparable to that of other reported fluorescent probes (Table S2).
3.6. Selectivity for the Detection of Glucose
Several interference experimental studies were conducted in the presence of interfering chemicals to determine the selectivity of TAP-COF-based colorimetric sensors for H2O2 detection (Figure 4D). The response of glucose (2 × 10−4 mmol·L−1) was up to 100 times greater than that of other substances (2 × 10−2 mol·L−1), none of which interfered with the measurement of glucose. These outcomes demonstrated the TAP-COF-based sensor exhibited superior glucose detection selectivity.
3.7. Colorimetric Detection Mechanism for H2O2
The cascade reaction-based colorimetric glucose assay is depicted in Figure 5A. The peroxidase-like activity of TAP-COF was derived from its catalytic H2O2 decomposition to produce ROS, mainly including singlet oxygen (1O2), hydroxyl radical (·OH), and superoxide anion (O2•−), where ·OH was a possible source of the catalytic process of TMB [36,37]. Next, capture experiments were used to test the ROS, and the catalytic mechanism and specificity of TAP-COF was further studied. As demonstrated in Figure 5B, the TMB + H2O2 + TAP-COF system showed different absorbance intensity with or without the addition of D-histidine (1O2 scavenger), tert-butyl alcohol (·OH scavenger), and benzoquinone (O2•− scavenger). The absorbance significantly decreased after the addition of tert-butyl, suggesting that the generated ·OH was scavenged by tert-butyl alcohol. Meanwhile, the system’s absorbance value exhibited no evident change after the addition of D-histidine and benzoquinone, indicating the specificity of TAP-COF peroxide-mimicking enzymes [38]. In summary, the peroxide-mimicking enzyme activity of TAP-COF mostly resulted from the ·OH, which was at odds with earlier studies on certain inorganic nanomaterials that were thought to originate via electron transport [39]. The electrocatalytic behavior of the TAP-COF and the FeTAPP modified GCE towards the electrochemical reduction of H2O2 was examined in further detail utilizing amperometric responses. Compared with the FeTAPP-modified electrode, the TAP-COF-modified electrode exhibited an enhanced reduction peak current, suggesting that TAP-COF exhibited higher electrocatalytic activity in the reduction of H2O2, which indicated that the TAP-COF had the better ability to accelerate the electron transfer (Figure 5C). Based on the above discussion, the possible explanation of TMB substrate oxidation by the TAP-COF catalyst in the presence of H2O2 might be proposed as follows: first, H2O2 entered the pores of TAP-COF or attached to the surface, and then the O–O bond of H2O2 broke to form ·OH. Second, ·OH oxidized TMB to produce a blue-colored byproduct. These phenomena indicated that the blue signal came from the charge transfer complex (chromogen). Electrochemical studies have indicated that there was a high degree of communication between the donor and acceptor of TAP-COF and the entire molecule’s electrical activity was governed by this connection. Moreover, the catalytic oxidation of TMB by H2O2 was aided by the D-A ordered structure of TAP-COF’s capacity to speed electron transport. Therefore, the design of TAP-COF with D-A properties was of great significance for the construction of novel colorimetric sensors.
3.8. Colorimetric Detection of Cancer Cells
H2O2 was an important component of several metabolic processes, including the metabolism of proteins and carbohydrates, and it may be used as a marker for a number of serious diseases, including cancer [40]. Then, samples with various MCF-7 cells ranging from 0–3000 cells·mL−1 were identified in 100 μL serial dilutions of binding buffer using TAP-COF as described above. Without including MCF-7 cells, the absorbance of the background was estimated using a similar approach (Figure 5D), and the absorbance at 650 nm was gathered for profiling. As demonstrated in Figure 5E, with the minimum cell concentration of 25 cells·mL−1 observed in our actual studies, a strong linear correlation was displayed between the colorimetric signal and the cell concentration (R2 > 0.98). This LOD was significantly lower than that attained using the currently available colorimetric cancer cell detection techniques, and even on par with that attained using electrochemical or fluorescent assays that are more sensitive [41,42,43]. The above results indicated that the TAP-COF-based colorimetric biosensor displayed a powerful ability to detect H2O2 released from cancer cells, and thus our proposed simple and convenient colorimetric assay could be used for the early diagnosis of cancer cells.
4. Conclusions
In conclusion, a new functional TAP-COF nanozyme with a donor–acceptor arrangement has been constructed through one-step condensation. The TAP-COF demonstrated increased enzyme mimicking activities for the direct catalysis of TMB to create blue oxTMB due to very efficient charge transfer, porous strutted structure, and the abundance of iron centers. Correspondingly, an H2O2-sensitive colorimetric detection method based on the TAP-COF sensing system was established by facilitating the electron change between H2O2 and TMB. The established colorimetric biosensor has high selectivity, excellent compatibility, and outstanding sensitivity, which was successfully used for the visual detection of H2O2 released from living cells. Our work provides a portable COF nanozyme-based sensing platform for the accurate detection of small molecule biomarkers, and a new perspective for point-of-care testing and medical diagnosis.
Supplementary Materials
The following supporting information can be downloaded at: https://www.mdpi.com/article/10.3390/bios13020188/s1. Figure S1: Schematic representation of the unit cell in the TAP-COF (A) top view and (B) side view; Figure S2: TGA data of TAP-COF; Figure S3: N2 adsorption-desorption isotherm curve of TAP-COF at 77 K; Figure S4: Exploring the impacts of this detection system, including (A) temperature, (B) pH, (C) TMB concentration, (D) COF concentration, and (E) H2O2 concentration; Figure S5: Steady-state kinetic analysis using the Michaelis-Menten model (A, B) and Lineweaver-Burk model (C, D) for TAP-COF. The concentration of H2O2 was 60 mM and TMB concentration was varied (A, C). The concentration of TMB was 0.80 mM and H2O2 concentration was varied (B, D); Table S1: Detection limit comparison of TAP-COF for H2O2 with some recently reported peroxidase mimics; Table S2: Comparison of analytical parameters for the determination of glucose. References [44,45,46,47,48,49,50,51,52,53,54,55,56,57,58,59] are cited in Supplementary Materials.
Author Contributions
Experiment design, data analysis, and manuscript preparation, Q.W. and L.L.; experiments, W.C.; investigation and data analysis, Y.B. and W.G.; supervision, funding acquisition, and formal analysis, P.Z. and J.Y. All authors have read and agreed to the published version of the manuscript.
Institutional Review Board Statement
Not applicable.
Informed Consent Statement
Not applicable.
Data Availability Statement
Not applicable.
Conflicts of Interest
The authors declare no conflict of interest.
Funding Statement
This research was funded by the National Natural Science Foundation of China (22276069) and the Shandong Provincial Natural Science Foundation (ZR2021MB047).
Footnotes
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.
References
- 1.Liu Y., Zhang H., Li B., Liu J., Jiang D., Liu B., Sojic N. Single Biomolecule Imaging by Electrochemiluminescence. J. Am. Chem. Soc. 2021;143:17910–17914. doi: 10.1021/jacs.1c06673. [DOI] [PubMed] [Google Scholar]
- 2.Jiao L., Xu W., Yan H., Wu Y., Liu C., Du D., Lin Y., Zhu C. Fe-N-C Single-Atom Nanozymes for the Intracellular Hydrogen Peroxide Detection. Anal. Chem. 2019;91:11994–11999. doi: 10.1021/acs.analchem.9b02901. [DOI] [PubMed] [Google Scholar]
- 3.Teodoro K.B.R., Migliorini F.L., Christinelli W.A., Correa D.S. Detection of Hydrogen Peroxide (H2O2) Using a Colorimetric Sensor Based on Cellulose Nanowhiskers and Silver Nanoparticles. Carbohydr. Polym. 2019;212:235–241. doi: 10.1016/j.carbpol.2019.02.053. [DOI] [PubMed] [Google Scholar]
- 4.Chen Y., Chen Z., Fang L., Weng A., Luo F., Guo L., Qiu B., Lin Z. Electrochemiluminescence Sensor for Cancer Cell Detection Based on H2O2-Triggered Stimulus Response System. J. Anal. Test. 2020;4:128–135. doi: 10.1007/s41664-020-00124-1. [DOI] [Google Scholar]
- 5.Chen Y., Shi X., Lu Z., Wang X., Wang Z. A Fluorescent Probe for Hydrogen Peroxide in Vivo Based on the Modulation of Intramolecular Charge Transfer. Anal. Chem. 2017;89:5278–5284. doi: 10.1021/acs.analchem.6b04810. [DOI] [PubMed] [Google Scholar]
- 6.Jain V., Bhagat S., Singh S. Bovine Serum Albumin Decorated Gold Nanoclusters: A Fluorescence-Based Nanoprobe for Detection of Intracellular Hydrogen Peroxide. Sens. Actuators B. 2021;327:128886. doi: 10.1016/j.snb.2020.128886. [DOI] [Google Scholar]
- 7.Ye S., Hu J.J., Yang D. Tandem Payne/Dakin Reaction: A New Strategy for Hydrogen Peroxide Detection and Molecular Imaging. Angew. Chem. Int. Ed. 2018;57:10173–10177. doi: 10.1002/anie.201805162. [DOI] [PubMed] [Google Scholar]
- 8.Kumar R., Han J., Lim H.J., Ren W.X., Lim J.Y., Kim J.H., Kim J.S. Mitochondrial Induced and Self-Monitored Intrinsic Apoptosis by Antitumor Theranostic Prodrug: In Vivo Imaging and Precise Cancer Treatment. J. Am. Chem. Soc. 2014;136:17836–17843. doi: 10.1021/ja510421q. [DOI] [PubMed] [Google Scholar]
- 9.Bhunia S.K., Dolai S., Sun H., Jelinek R. “On/Off/On” Hydrogen-Peroxide Sensor with Hemoglobin-Functionalized Carbon Dots. Sens. Actuators B. 2018;270:223–230. doi: 10.1016/j.snb.2018.05.029. [DOI] [Google Scholar]
- 10.Shi Y., Wu Q., Li W., Lin L., Qu F., Shen C., Wei Y., Nie P., He Y., Feng X. Ultra-Sensitive Detection of Hydrogen Peroxide and Levofloxacin Using a Dual-Functional Fluorescent Probe. J. Hazard. Mater. 2022;432:128605. doi: 10.1016/j.jhazmat.2022.128605. [DOI] [PubMed] [Google Scholar]
- 11.Rajendran S., Zichri S.B., Usha Vipinachandran V., Jelinek R., Bhunia S.K. Triphenylphosphonium-Derived Bright Green Fluorescent Carbon Dots for Mitochondrial Targeting and Rapid Selective Detection of Tetracycline. ChemNanoMat. 2021;7:545–552. doi: 10.1002/cnma.202100125. [DOI] [Google Scholar]
- 12.Kitte S.A., Gao W., Zholudov Y.T., Qi L., Nsabimana A., Liu Z., Xu G. Stainless Steel Electrode for Sensitive Luminol Electrochemiluminescent Detection of H2O2, Glucose, and Glucose Oxidase Activity. Anal. Chem. 2017;89:9864–9869. doi: 10.1021/acs.analchem.7b01939. [DOI] [PubMed] [Google Scholar]
- 13.Zhao J., Dong W., Zhang X., Chai H., Huang Y. FeNPs@Co3O4 Hollow Nanocages Hybrids as Effective Peroxidase Mimics for Glucose Biosensing. Sens. Actuators B. 2018;263:575–584. doi: 10.1016/j.snb.2018.02.151. [DOI] [Google Scholar]
- 14.UshaVipinachandran V., Rajendran S., Ali H., Ashokan I., Bhunia S.K. Citrate Capped Silver Nanoparticles as an Instantaneous Colorimetric Selective Sensor for Neomycin and Thiamine in Wastewater. New J. Chem. 2022;46:14081–14090. doi: 10.1039/D2NJ02174A. [DOI] [Google Scholar]
- 15.Liu H., Ding Y., Yang B., Liu Z., Liu Q., Zhang X. Colorimetric and Ultrasensitive Detection of H2O2 Based on Au/Co3O4-CeOx Nanocomposites with Enhanced Peroxidase-Like Performance. Sens. Actuators B. 2018;271:336–345. doi: 10.1016/j.snb.2018.05.108. [DOI] [Google Scholar]
- 16.Lin A., Liu Q., Zhang Y., Wang Q., Li S., Zhu B., Miao L., Du Y., Zhao S., Wei H. A Dopamine-Enabled Universal Assay for Catalase and Catalase-Like Nanozymes. Anal. Chem. 2022;94:10636–10642. doi: 10.1021/acs.analchem.2c00804. [DOI] [PubMed] [Google Scholar]
- 17.Fan X., Tian R., Wang T., Liu S., Wang L., Xu J., Liu J., Ma M., Wu Z. An Ultrathin Iron-Porphyrin Based Nanocapsule with High Peroxidase-Like Activity for Highly Sensitive Glucose Detection. Nanoscale. 2018;10:22155–22160. doi: 10.1039/C8NR07288D. [DOI] [PubMed] [Google Scholar]
- 18.Liu J., He X., Wang K., He D., Wang Y., Mao Y., Shi H., Wen L. A Highly Sensitive Electrochemiluminescence Assay for Protein Kinase Based on Double-Quenching of Graphene Quantum Dots by G-quadruplex-Hemin and Gold Nanoparticles. Biosens. Bioelectron. 2015;70:54–60. doi: 10.1016/j.bios.2015.03.026. [DOI] [PubMed] [Google Scholar]
- 19.Li Y., Fang Y., Gao W., Guo X., Zhang X. Porphyrin-Based Porous Organic Polymer as Peroxidase Mimics for Sulfide-Ion Colorimetric Sensing. ACS Sustain. Chem. Eng. 2020;8:10870–10880. doi: 10.1021/acssuschemeng.0c03045. [DOI] [Google Scholar]
- 20.Liu Q., Chen P., Xu Z., Chen M., Ding Y., Yue K., Xu J. A Facile Strategy to Prepare Porphyrin Functionalized ZnS Nanoparticles and Their Peroxidase-Like Catalytic Activity for Colorimetric Sensor of Hydrogen Peroxide and Glucose. Sens. Actuators B. 2017;251:339–348. doi: 10.1016/j.snb.2017.05.069. [DOI] [Google Scholar]
- 21.Li D., Fang Y., Zhang X. Bacterial Detection and Elimination Using a Dual-Functional Porphyrin-Based Porous Organic Polymer with Peroxidase-Like and High Near-Infrared-Light-Enhanced Antibacterial Activity. ACS Appl. Mater. Interfaces. 2020;12:8989–8999. doi: 10.1021/acsami.9b20102. [DOI] [PubMed] [Google Scholar]
- 22.Xiang Z., Xue Y., Cao D., Huang L., Chen J.F., Dai L. Highly Efficient Electrocatalysts for Oxygen Reduction Based on 2D Covalent Organic Polymers Complexed with Non-Precious Metals. Angew. Chem. Int. Ed. 2014;53:2433–2437. doi: 10.1002/anie.201308896. [DOI] [PubMed] [Google Scholar]
- 23.Zhu P., Li S., Zhou S., Ren N., Ge S., Zhang Y., Wang Y., Yu J. In Situ Grown COFs on 3D Strutted Graphene Aerogel for Electrochemical Detection of NO Released from Living Cells. Chem. Eng. J. 2021;420:127559. doi: 10.1016/j.cej.2020.127559. [DOI] [Google Scholar]
- 24.Xie Y., Xu M., Wang L., Liang H., Wang L., Song Y. Iron-Porphyrin-Based Covalent-Organic Frameworks for Electrochemical Sensing H2O2 and pH. Mater. Sci. Eng. C. 2020;112:110864. doi: 10.1016/j.msec.2020.110864. [DOI] [PubMed] [Google Scholar]
- 25.Li G., Tian W., Zhong C., Yang Y., Lin Z. Construction of Donor-Acceptor Heteroporous Covalent Organic Frameworks as Photoregulated Oxidase-Like Nanozymes for Sensing Signal Amplification. ACS Appl. Mater. Interfaces. 2022;14:21750–21757. doi: 10.1021/acsami.2c04391. [DOI] [PubMed] [Google Scholar]
- 26.Liu K., Qi H., Dong R., Shivhare R., Addicoat M., Zhang T., Sahabudeen H., Heine T., Mannsfeld S., Kaiser U., et al. On-Water Surface Synthesis of Crystalline, Few-Layer Two-Dimensional Polymers Assisted by Surfactant Monolayers. Nat. Chem. 2019;11:994–1000. doi: 10.1038/s41557-019-0327-5. [DOI] [PubMed] [Google Scholar]
- 27.Han B., Ding X., Yu B., Wu H., Zhou W., Liu W., Wei C., Chen B., Qi D., Wang H., et al. Two-Dimensional Covalent Organic Frameworks with Cobalt(II)-Phthalocyanine Sites for Efficient Electrocatalytic Carbon Dioxide Reduction. J. Am. Chem. Soc. 2021;143:7104–7113. doi: 10.1021/jacs.1c02145. [DOI] [PubMed] [Google Scholar]
- 28.Ma P., Kan J., Zhang Y., Hang C., Bian Y., Chen Y., Kobayshi N., Jiang J. The First Solution-Processable n-Type Phthalocyaninato Copper Semiconductor: Tuning the Semiconducting Nature Via Peripheral Electron-Withdrawing Octyloxycarbonyl Substituents. J. Mater. Chem. 2011;21:18552–18559. doi: 10.1039/c1jm13082j. [DOI] [Google Scholar]
- 29.Chandra S., Kundu T., Dey K., Addicoat M., Heine T., Banerjee R. Interplaying Intrinsic and Extrinsic Proton Conductivities in Covalent Organic Frameworks. Chem. Mater. 2016;28:1489–1494. doi: 10.1021/acs.chemmater.5b04947. [DOI] [Google Scholar]
- 30.Zhao C., Zhang L., Wang Q., Zhang L., Zhu P., Yu J., Zhang Y. Porphyrin-Based Covalent Organic Framework Thin Films as Cathodic Materials for “On–Off–On” Photoelectrochemical Sensing of Lead Ions. ACS Appl. Mater. Interfaces. 2021;13:20397–20404. doi: 10.1021/acsami.1c00335. [DOI] [PubMed] [Google Scholar]
- 31.Lu D., Li J., Wu Z., Yuan L., Fang W., Zou P., Ma L., Wang X. High-Activity Daisy-Like Zeolitic Imidazolate Framework-67/Reduced Grapheme Oxide-Based Colorimetric Biosensor for Sensitive Detection of Hydrogen Peroxide. J. Colloid Interface Sci. 2022;608:3069–3078. doi: 10.1016/j.jcis.2021.11.034. [DOI] [PubMed] [Google Scholar]
- 32.Deng X., Fang Y., Lin S., Cheng Q., Liu Q., Zhang X. Porphyrin-Based Porous Organic Frameworks as a Biomimetic Catalyst for Highly Efficient Colorimetric Immunoassay. ACS Appl. Mater. Interfaces. 2017;9:3514–3523. doi: 10.1021/acsami.6b15637. [DOI] [PubMed] [Google Scholar]
- 33.Xie J., Cao H., Jiang H., Chen Y., Shi W., Zheng H., Huang Y. Co3O4-Reduced Graphene Oxide Nanocomposite as an Effective Peroxidase Mimetic and Its Application in Visual Biosensing of Glucose. Anal. Chim. Acta. 2013;796:92–100. doi: 10.1016/j.aca.2013.08.008. [DOI] [PubMed] [Google Scholar]
- 34.Liu Y.L., Zhao X.J., Yang X.X., Li Y.F. A Nanosized Metal-Organic Framework of Fe-MIL-88NH2 as a Novel Peroxidase Mimic Used for Colorimetric Detection of Glucose. Analyst. 2013;138:4526–4531. doi: 10.1039/c3an00560g. [DOI] [PubMed] [Google Scholar]
- 35.Shi W., Wang Q., Long Y., Cheng Z., Chen S., Zheng H., Huang Y. Carbon Nanodots as Peroxidase Mimetics and Their Applications to Glucose Detection. Chem. Commun. 2011;47:6695–6697. doi: 10.1039/c1cc11943e. [DOI] [PubMed] [Google Scholar]
- 36.Zheng D.J., Yang Y.S., Zhu H.L. Recent Progress In the Development of Small-Molecule Fluorescent Probes for the Detection of Hydrogen Peroxide. TrAC Trends Anal. Chem. 2019;118:625–651. doi: 10.1016/j.trac.2019.06.031. [DOI] [Google Scholar]
- 37.Zhang Y., Xu J., Zhou S., Zhu L., Lv X., Zhang J., Zhang L., Zhu P., Yu J. DNAzyme-Triggered Visual and Ratiometric Electrochemiluminescence Dual-Readout Assay for Pb(II) Based on an Assembled Paper Device. Anal. Chem. 2020;92:3874–3881. doi: 10.1021/acs.analchem.9b05343. [DOI] [PubMed] [Google Scholar]
- 38.Hu F.X., Miao J., Guo C., Yang H.B., Liu B. Real-Time Photoelectrochemical Quantification of Hydrogen Peroxide Produced by Living Cells. Chem. Eng. J. 2021;407:127203. doi: 10.1016/j.cej.2020.127203. [DOI] [Google Scholar]
- 39.Dong Y.L., Zhang H.G., Rahman Z.U., Su L., Chen X.J., Hu J., Chen X.G. Graphene Oxide-Fe3O4 Magnetic Nanocomposites with Peroxidase-Like Activity for Colorimetric Detection of Glucose. Nanoscale. 2012;4:3969–3976. doi: 10.1039/c2nr12109c. [DOI] [PubMed] [Google Scholar]
- 40.Zhu D., Kong H., Yang G., He P., Luan X., Guo L., Wei G. Peptide Nanosheet-Inspired Biomimetic Synthesis of CuS Nanoparticles on Ti3C2 Nanosheets for Electrochemical Biosensing of Hydrogen Peroxide. Biosensors. 2022;13:14. doi: 10.3390/bios13010014. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 41.Lu W., Arumugam S., Senapati D., Khan S.A., Yu H., Ray P. Multifunction Oval-Shaped Gold-Nanoparticle-Based Selective Detection of Breast Cancer Cells Using Simple Colorimetric and Highly Sensitive Two-Photon Scattering Assay. ACS Nano. 2010;4:1739–1749. doi: 10.1021/nn901742q. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 42.Sun H., Gao Y., Hu N., Zhang Y., Guo C., Gao G., Ma Z., Ivan Ivanovich K., Qiu Y. Electronic Coupling Between Molybdenum Disulfide and Gold Nanoparticles to Enhance the Peroxidase Activity for the Colorimetric Immunoassays of Hydrogen Peroxide and Cancer Cells. J. Colloid Interface Sci. 2020;578:366–378. doi: 10.1016/j.jcis.2020.06.001. [DOI] [PubMed] [Google Scholar]
- 43.Li M., Lao Y.H., Mintz R.L., Chen Z., Shao D., Hu H., Wang H.X., Tao Y., Leong K.W. A Multifunctional Mesoporous Silica-Gold Nanocluster Hybrid Platform for Selective Breast Cancer Cell Detection Using a Catalytic Amplification-Based Colorimetric Assay. Nanoscale. 2019;11:2631–2636. doi: 10.1039/C8NR08337A. [DOI] [PubMed] [Google Scholar]
- 44.Abdinejad M., Dao C., Zhang X.A., Kraatz H.B. Enhanced Electrocatalytic Activity of Iron Amino Porphyrins Using a Flow Cell for Reduction of CO2 to CO. J. Energy Chem. 2021;58:162–169. doi: 10.1016/j.jechem.2020.09.039. [DOI] [Google Scholar]
- 45.Pegis M.L., Martin D.J., Wise C.F., Brezny A.C., Johnson S.I., Johnson L.E., Kumar N., Raugei S., Mayer J.M. Mechanism of Catalytic O2 Reduction by Iron Tetraphenylporphyrin. J. Am. Chem. Soc. 2019;141:8315–8326. doi: 10.1021/jacs.9b02640. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 46.Hartnett P.E., Mauck C.M., Harris M.A., Young R.M., Wu Y.L., Marks T.J., Wasielewski M.R. Influence of Anion Delocalization on Electron Transfer in a Covalent Porphyrin Donor-Perylenediimide Dimer Acceptor System. J. Am. Chem. Soc. 2017;139:749–756. doi: 10.1021/jacs.6b10140. [DOI] [PubMed] [Google Scholar]
- 47.Zhang C., Zhang S., Yan Y., Xia F., Huang A., Xian Y. Highly Fluorescent Polyimide Covalent Organic Nanosheets as Sensing Probes for the Detection of 2,4,6-Trinitrophenol. ACS Appl. Mater. Interfaces. 2017;9:13415–13421. doi: 10.1021/acsami.6b16423. [DOI] [PubMed] [Google Scholar]
- 48.Cui C., Wang Q., Liu Q., Deng X., Liu T., Li D., Zhang X. Porphyrin-Based Porous Organic Framework: An Efficient and Stable Peroxidase-Mimicking Nanozyme for Detection of H2O2 and Evaluation of Antioxidant. Sens. Actuators, B. 2018;277:86–94. doi: 10.1016/j.snb.2018.08.097. [DOI] [Google Scholar]
- 49.Wang N., Sun J., Chen L., Fan H., Ai S. A Cu2(OH)3Cl-CeO2 Nanocomposite with Peroxidase-Like Activity, and Its Application to the Determination of Hydrogen Peroxide, Glucose and Cholesterol. Microchim. Acta. 2015;182:1733–1738. doi: 10.1007/s00604-015-1506-8. [DOI] [Google Scholar]
- 50.Socaci C., Pogacean F., Biris A.R., Coros M., Rosu M.C., Magerusan L., Katona G., Pruneanu S. Graphene Oxide vs. Reduced Graphene Oxide as Carbon Support in Porphyrin Peroxidase Biomimetic Nanomaterials. Talanta. 2016;148:511–517. doi: 10.1016/j.talanta.2015.11.023. [DOI] [PubMed] [Google Scholar]
- 51.Yang H., Zha J., Zhang P., Xiong Y., Su L., Ye F. Sphere-Like CoS with Nanostructures as Peroxidase Mimics for Colorimetric Determination of H2O2 and Mercury Ions. RSC Adv. 2016;6:66963–66970. doi: 10.1039/C6RA16619A. [DOI] [Google Scholar]
- 52.Liu Q., Yang Y., Lv X., Ding Y., Zhang Y., Jing J., Xu C. One-Step Synthesis of Uniform Nanoparticles of Porphyrin Functionalized Ceria with Promising Peroxidase Mimetics for H2O2 and Glucose Colorimetric Detection. Sens. Actuators, B. 2017;240:726–734. doi: 10.1016/j.snb.2016.09.049. [DOI] [Google Scholar]
- 53.Chen H., Shi Q., Deng G., Chen X., Yang Y., Lan W., Hu Y., Zhang L., Xu L., Li C., et al. Rapid and Highly Sensitive Colorimetric Biosensor For the Detection of Glucose and Hydrogen Peroxide Based on Nanoporphyrin Combined with Bromine as a Peroxidase-Like Catalyst. Sens. Actuators, B. 2021;343:130104. doi: 10.1016/j.snb.2021.130104. [DOI] [Google Scholar]
- 54.Jin L., Shang L., Guo S., Fang Y., Wen D., Wang L., Yin J., Dong S. Biomolecule-Stabilized Au Nanoclusters as a Fluorescence Probe for Sensitive Detection of Glucose. Biosens. Bioelectron. 2011;26:1965–1969. doi: 10.1016/j.bios.2010.08.019. [DOI] [PubMed] [Google Scholar]
- 55.Liu L.M., Wen J., Liu L., He D., Kuang R.Y., Shi T. A Mediator-Free Glucose Biosensor Based on Glucose Oxidase/Chitosan/Alpha-Zirconium Phosphate Ternary Biocomposite. Anal. Biochem. 2014;445:24–29. doi: 10.1016/j.ab.2013.10.005. [DOI] [PubMed] [Google Scholar]
- 56.Wang L., Zhu W., Lu W., Shi L., Wang R., Pang R., Cao Y., Wang F., Xu X. One-Step Electrodeposition of AuNi Nanodendrite Arrays as Photoelectrochemical Biosensors for Glucose and Hydrogen Peroxide Detection. Biosens. Bioelectron. 2019;142:111577. doi: 10.1016/j.bios.2019.111577. [DOI] [PubMed] [Google Scholar]
- 57.Xia Y., Huang W., Zheng J., Niu Z., Li Z. Nonenzymatic Amperometric Response of Glucose on A Nanoporous Gold Film Electrode Fabricated by A Rapid and Simple Electrochemical Method. Biosens. Bioelectron. 2011;26:3555–3561. doi: 10.1016/j.bios.2011.01.044. [DOI] [PubMed] [Google Scholar]
- 58.Aksorn J., Teepoo S. Development of The Simultaneous Colorimetric Enzymatic Detection of Sucrose, Fructose and Glucose Using a Microfluidic Paper-based Analytical Device. Talanta. 2020;207:120302. doi: 10.1016/j.talanta.2019.120302. [DOI] [PubMed] [Google Scholar]
- 59.Wang K., Li N., Zhang J., Zhang Z., Dang F. Size-Selective QD@MOF Core-Shell Nanocomposites for the Highly Sensitive Monitoring of Oxidase Activities. Biosens. Bioelectron. 2017;87:339–344. doi: 10.1016/j.bios.2016.08.026. [DOI] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Supplementary Materials
Data Availability Statement
Not applicable.