. 2023 Feb 25;13:3268. doi: 10.1038/s41598-023-30375-8

Estimation of optimal tilt angles for photovoltaic panels in Egypt with experimental verifications

Ashraf K Abdelaal 1,, Attia El-Fergany 2
PMCID: PMC9968325  PMID: 36841921

Abstract

The principal target of this work is to compute the optimal tilt angle (OTA) for Photovoltaic (PV) panels. To perform this task, comprehensive simulations are done starting from altering the tilt angle (TA) daily, to use one fixed TA for all the year. The mathematical models for extra-terrestrial radiation (ETR) of both horizontal and inclined surfaces are presented firstly. At a later stage, the optimization formulation for the maximizing the solar radiation (SR) is adapted, and then the daily, monthly, seasonally, half-yearly and optimal fixed TAs are obtained. Although, the daily OTA produces the maximum SR, it is costly and impractical. It is found that altering the TA twice a year at optimal values that are computed as 5° and 50° for Suez city, gives the best results that are very near to the daily altering of the OTA. The difference between the two methods is 1.56% which is very small. Also, the two OTAs has SR better than that of the fixed OTA which is 28° by 7.77%. Also, it is found that the yearly fixed OTA (28°) is nearly equal to the latitude angle of Suez city which is 30°. The two OTAs method of this paper is different from the commonly used method that suggests two TAs. The first TA is used for winter months which is obtained by adding 15° to the latitude angle while the second TA is obtained by subtracting 15° from the latitude angle for the summer months. This commonly used method produces lesser SR than the two OTAs method of this paper. The theoretical work has been proved by an experimental work on two PV systems constructed at 25° and 30° TAs. The results of the experimental work agree with the theoretical results.

Subject terms: Electrical and electronic engineering, Engineering

Introduction

Due to the harmful effects of climate change, the world tries to reduce CO2 emissions and air pollution. The world has a strong desire to quickly move towards zero carbon emission energy sources such as renewable energies. In the last decade, utility scale solar PV systems are growing very fast, and their costs are continuing falling driving utilities to install more of these energy sources for electrical energy production. There are several variables disturbing the energy output of the PV panels13. One of these variables is the tilt or slope angle of the PV arrays. The TA is defined as the slope angle of the PV panel to the horizontal plane.

Many researchers were implemented in many countries to calculate the OTA. Zamora4 investigated the TA of the PV panel in areas with small values of latitude angles. A method is used by Agrawal and Chhajed5 in areas near the equator to enhance SR by 18.4%. A solar system is used by Shariah et al.6 to heat water in Jordon with TA varies from 0 to 20 depending on the city. A study was done by Osmani et al.7 to relate economics with the TA, in which they tried to reduce the price of energy and at the same time, reduces the installation costs. Liu et al.8 implemented a study in China to compute the TA by using measured data without giving any values for the OTA. Umunnakwe et al.9, research has been done to compute the OPT in many countries around the world; one of them is Sharm El-Sheikkh, Egypt with OTA of 23.2° which is agreed with the OTA presented in this paper. Karinka and Upadhyaya 10 introduced a method to compute the OPT and they conclude that 12.0% of energy reduction if the tilt angle is not varied each month, which contradicts with the outcomes of this paper. Abdallah et al.11 made a comparison between SR of Horizontal Surface (HS) with that of the tilted surface which is varied each month with different 15%, which is less than the SR of this paper which is 24%. Xu et al.12 suggested a technique to compute the OTA on hilly places.

Yadav et al.13 suggested a method to compute the OPT in the presence of houses shadow. Similar objectives could be found in1416. Mansour et al.17, a similar study to get the OTA for different cities in Saudi Arabia. Tiris and Tiris in 18, Tiris and Tiris tried to compute the OTA of a collector system depending on the highest SR. Sarr et al.19, made a study to get the OTA in Senegal. They concluded that, the PV panel must be directed towards south in the north half of the earth, consequently the angle of azimuth is zero. Then the PV panels should be tilted to the horizontal by a TA. They mentioned that the OTA is not identical to the place latitude angle. Al-Sayyab et al.20 suggested that the TA in Basrah city (latitude 30) is 28 which agree with the result of this work. Chih-Chiang Wei21 presented evaluation models to forecast the sun energy radiation on tilted surfaces. In22,23 a simple correlation is presented to compute the mean monthly daily global radiation. Qasaimeh et al.24 implemented a study in Jordon to compute the OTAs and they concluded that their values are limited between 10° and 60°. Li et al.25 a mathematical method is presented to compute the SR on tilted surfaces by incorporating the measured sky radiation scattering. Then the yearly radiation at tilted collectors were determined. Islam et al.26 made a study to compute the OTA at Dhaka (latitude is 23.81°). It is found that the value of the OTA is 20.83° at Dhaka.

A more practical study is done by Benghanem27, in which he tried to calculate the OTA depending on measuring the values of the global daily SR and the diffuse SR on a flat surface. The OTA is computed, and it is nearly equivalent to the latitude angle. Also, they Clearfield that the OTA computed at each month has total radiation better than the optimum constant TA by 8%. Calabr28 proposed a technique to compute the OTA of PV system by using both the SR computed on horizontal plane and the data provided from weather stations. He concluded that the OTA can be computed from the latitude angle by a linear regression. Ahmad et al.29 analyzed the influence of the latitude angle on the working of sun trackers is tested and concluded that the performance of these sun tracked is highly dependent on the latitude angle. Alatarawneh et al.30 made a study to find out the importance of SR in Jordon and finding the OTA. While the latitude angle is 30.19°, the yearly optimal fixed TA is obtained to be 28.7°. The SR at the calculated optimal angle is higher than the SR at that of the latitude angle by 0.2%. They recommended that altering the panel angles four times a year which is not practical.

Khorasanizadeh and Mohammadi31 the OTA in the Iranian city of Tabass is determined. The yearly optimum tilt is 32°, while the latitude angle of Tabass is 33.36°. Jafarkazemi and Saadabadi32 computed the yearly OTA for Abu Dhabi city and its value was equal to 22° which was near to Abu Dhabi latitude 24.4°. Darhmaoui and Lahjouji33 showed that the difference between the experimental and the mathematical OTA is 8º which is too high. Kecili et al.34 Suggested many schemes for the OTA, and claimed that the number of variations of the TA increase, the SR will increase.

Salari and Javaran35, stated that 23% increase in SR in case of using fixed OTA| compared with the HS, which is overestimated. Ahmad and Tiwari36 presented a study to increase the SR on Horizontal dish, and claimed that the seasonal OTA is the best way to get highest SR. Many references claimed that the value of the TA has the same value as the latitude angle ± 15°. Where the positive sign is used in winter days and the negative sign is used in summer days. Similar work was done by Abed and Al-Salami37 in Turkey.

All the previous methods show some important facts as follows: (i) the importance of the TA for high efficiency of PV systems, (ii) the value of the OTA has a strong relation with the latitude angle, and (iii) the world is directed to use solar energy instead of fossil fuel.

Since Egypt has sunny days all over the year especially in the south. Egypt is directed to use solar energy and to build many plants around the country. One of these recommended areas is the Suez area that has high level of SR with very low clouds all the year and it is selected for this study beside three other cities to cover most of the Egyptian land. Also, Suez is near to the load center and has sunny climate inspires the Egyptian government and other international companies to build many PV systems there.

The main contributions of this work are: (i) If no TA is used, the PV system may lose a 95% of its daily SR or 24% of its annual SR, (ii) The two OTAs method of this paper is nearly equivalent to the daily altering of the OTA, (iii) One optimal fixed tilt can be used but its SR will be lesser by 7.01% than the two OTAs method, (iv) The fixed OTA is very near to the latitude angle, always lesser by 2°, and (v) Latitude angle can be used as a suboptimal TA with very small error.

This paper is organized as follow: the first part gives short review in the work done in the computation of the TA methods. The second part explains in short, the main governing equations to calculate the horizontal and tilted surfaces extraterrestrial sun radiation. Section “The importance of TA for PV system” explains the importance of the TA for optimizing the SR. Section “Problem formulation” puts the SR in a mathematical optimization form. Section “Simulation results” introduces 5 cases for computing OTAs. The last section displays the experiential work that has been implemented.

Extraterrestrial SR relations

The following variables and parameters affect the solar energy radiation received by the PV arrays38.

The solar constant Gsc

The solar constant Gsc is the value of the energy gained by the earth on one square meter. It has a value of 1353.0 W/m2 with an inaccuracy of ± 1.5%. Gsc of value 1367.0 W/m2 is used in this paper.

The earth-sun distance

Earth moves throughout the sun in an oval path. Therefore, the sun-earth distance changes from day to another. The mean distance between sun and earth is 150 Mkm. The quadratic of the reciprocal distance ratio between the earth and the sun, is given as Eo.

Eo=(ro/r)2=1.00011+0.034221cosμ+0.00128sinμ+0.000719cos2μ+0.000077sin2μ 1

Eo is termed as the eccentricity modification factor of the earth’s path38, and μ is the angle cut by one day in radians.

Solar declination (δ)

The earth moves throughout the polar axis, which has a slope of 23.5° from the equatorial plane. Meanwhile the vertex angle formed by the line connecting both earth and sun centers and the normal line to the center plane of the earth is known as the solar declination angle (δ). This angle changes every day. It has zero value at both spring equinox and autumnal equinox. δ is approximately equal to + 23.5° at the summer solstice and about − 23.5° at the winter solstice (for north half of the earth). The following expression for δ, in degrees38:

δ=(0.006918-0.399912cosμ+0.070257sinμ-0.006758cos2μ+0.000907sin2μ-0.002697cos3μ+0.00148sin3μ)180π 2

The hour angle (ω) is the angle measured at the celestial pole between the spectator’s meridian and the sun meridian. It is measured from mid-day, and it has 15° per one hour.

The sunrise hour angle ωs could be calculated as expressed in (3).

ωs=cos-1-tanφtanδ 3

Assuming that the PV panels are directed toward the equator, then the sunset hour angle is identical to the minus of the sunrise hour angle.

The ETR on a horizontal surface

The daily SR outside the earth on a HS is given by the following equation:

Ho=24πISCEosinφ.sinδ.π180ωs-tanωs 4

The daily ETR on a tilted surface

The daily radiation outside the earth on a tilted surface is given by the following equation:

Hoβ=24πISCEoπ180ωssinδsinφ-β+cosδcosφ-βsinωs,ωs>ωs 5

Or

Hoβ=24πISCEoπ180ωssinδsinφ-β+cosδcosφ-βsinωs,ωsωs 6

where

ωs=min{ωs,cos-1-tanδtanφ-β} 7

Sun path

The sun path is a picture of the sun's motion across the sky at specified location. With the help of the sun path, the azimuth and sun rise angles can be calculated. The sun path at Suez University (Latitude = 29.9987° and Longitude 32.5044°) is shown in Fig. 1 using the method described in39.

Figure 1.

Figure 1

Sun-paths for Suez University.

The importance of TA for PV system

If someone is interested to get the maximum SR on a specified day (consider it as first of January) on Suez University area where the latitude is 29° 59′ 55.68ʺ N. According to that day the following has been calculated as φ = 29° 59′ 55.68ʺ = 29.9988° at Day number = 1 (first day in the year) as follows:

  • Day Angle = μ=2πn-1/365 = 360(1–1)/365 = 0,

  • The earth-sun distance ratio is Eo=(ror)2 from Eq. (1), one can get Eo = (ro/r)2 = 1.0351,

  • The declination angle δ is calculated using Eq. (2) and for January 1st δ = − 23.0558°,

  • It should be remembered that both Eo and δ depends only on the day number and not in the TA. The sunrise angle is represented by Eq. (3) which gives ωs=75.7768o, and

  • The Daily Radiation value on a HS on that place is calculated from Eq. (4) or Ho=6.8974 kWh/ m2/day.

The ETR on inclined surface directed to south

The daily ETR on a inclined surface directed to the south can be calculated from Eqs. (5) or (6), and the value of ωs can be calculated from Eq. (7) as ωs=min{75.7768,cos-1-tanδtanφ-β} . 

If Eqs. (5) or (6) is simulated using MATLAB for dissimilar TAs varying from 0° to 90°, for a specific day for example 1st of January, the following curve shown in Fig. 2 is obtained. The maximum radiation at January first on a tilted surface is 11.1167 kWh and is obtained at TA of 60°. The radiation is increased from 5.7011 kWh at zero TA to 11.1167 kWh at OTA for that day of 60°. The percentage increase in radiation is 95% which indicates the significance of the TA.

Figure 2.

Figure 2

The influence of TA variation on extraterrestrial solar radiation.

Another important question is that how many times should the TA to be changed per year? Should the TA to be changed 365 times per year (daily), 12 times per year (monthly), 4 times per year (seasonally), 2 times per year or fixed at suboptimal angle? To answer this question, the maximum total radiation is the main factor for selecting the OTA. A simulation has been made for all days in the year for TAs from 0° to 90° and the simulation results are given in Fig. 3 which displays the optimum daily TA for all days of the year for Suez city (Latitude 29.9988° ≈ 30°). According to Fig. 1, one can select how many times that can be used for the TA along the year.

Figure 3.

Figure 3

Optimal values of daily TAs.

The curve has symmetry around June month. Also, one can notice that the year can be distributed into three intervals. The first interval is the winter season, starting from 1st of January to 28 of February, of total 59 days. The key feature of this interval is that the OTA is decreasing during January and February, while it is increasing during November and December. Based on the previous discussion an optimum TA of 50° will be chosen for that interval. A closer look to Fig. 3, the reader can notice that during summer months from May to August, the TA is 1°. This can be explained using the sun path curves shown in Fig. 1 for these months. The sun paths during these months have flatted top as shown in Fig. 1 for many hours, so the sun rays are nearly normal to the earth during these hours. So, to harness more radiation it is better to make the PV panels nearly horizontal or tilted at very small angle. For these months, the OTA is 1°.

Problem formulation

The main goal is to get the highest yearly solar radiation. So, our objective function can be adapted to maximize the yearly total radiation as per Eqs. (5) and (6). This function has discontinuity at ωs since the condition ωsωs in the objective function, and subject to the following constraints as depicted in Eqs. (8) to (13).

μ=2πn-1/365 8
Eo=1.00011+0.034221cosμ+0.00128sinμ+0.000719cos2μ+0.000077sin2μ 9
δ=0.006918-0.399912cosμ+0.070257sinμ-0.006758cos2μ+0.000907sin2μ-0.002697cos3μ+0.00148sin3μ180π 10
ωs=cos-1(-tanφtanδ) 11
ωs=minωs,cos-1-tanδtanφ-β 12
0β90o 13

This is an optimization problem, but unfortunately it has two difficulties the first is the discontinuity in the objective function which is depends on the TA, and the second difficulty is the summing in the objective function. The flow chart in Fig. 4 shows the computation procedure to calculate the SR for certain tilt angle β for interval K. While the flow chart displayed in Fig. 5 illustrate the process to obtain the OTA β for a specified interval K.

Figure 4.

Figure 4

Computation procedure to calculate the SR for certain tilts angle β.

Figure 5.

Figure 5

Computation of the OTA β for a specified interval K.

Simulation results

In this section, many scenarios are anticipated for further demonstration to validate the proposed approach. Based on both Figs. 1 and 3, the following scenarios are considered:

  1. Zero TA or horizontal panel.

  2. Daily altering of the TA of the panel.

  3. Monthly altering of the TA of the panel.

  4. Seasonal altering of the TA of the panel.

  5. Two times altering of the TA of the panel.

  6. Fixed TA.

It must be remembered that the TA changes will add additional cost to the PV systems costs. The optimization problem has been solved by a program written in MATLAB. The coming subsections detailed the analysis, discussions, and comprehensive results.

Zero TA or horizontal PV panel

The ETR at HS or zero TA is 3204.5 kWh/ m2/ year which is calculated for Suez city.

Daily altering of the TA

If the PV scheme is tilted daily at an OTA, the SR will be changed according to each day OTA. Figure 6 displays the total yearly extraterrestrial SR at daily OTA for four cities. The yearly SR for Suez city is 3974.6 kWh/ m2/year with a daily average value of 10.8894 kWh/day/m2. The curve is simulated by calculating the daily radiation for each TA starting from 1° to 90°, and then the angle of maximum radiation is obtained. This case is higher than the radiation of HS by 770.1 kWh in a year or 24%. This can save money. Some interesting notes can be noticed from Fig. 4, for example the maximum daily radiation in all the year is obtained at day number 172 (21st of June) with corresponding OTA of 1°. This can be explained by remembering that this day is the longest day in the year with sun shining for more than 14 h. Table 1 shows the OTAs with their corresponding total radiation at certain days in the year for 4 different places in Egypt. These places are chosen to cover most of the Egyptian country. The radiations at these cities are shown in Fig. 6.

Figure 6.

Figure 6

Solar radiation versus optimal daily TA for some cities in Egypt.

Table 1.

Optimal daily angle and radiation.

City Suez Binban Sharm Elshiekh Marsa Matrough
Day number OTA
Deg
Radiation
kWh/m2
OTA
Deg
Radiation
kWh/m2
OTA
Deg
Radiation
kWh/m2
OTA
Deg
Radiation
kWh/m2
1 60 11.148 55 11.364 58 11.23 61 11.087
17 58 11.127 53 11.297 56 11.19 59 11.079
45 49 10.92 44 10.975 47 10.94 50 10.9
74 34 10.57 28 10.57 32 10.57 35 10.57
105 15 10.586 9 10.586 13 10.586 16 10.586
135 1 11.1 1 11.015 1 11.08 1 11.108
161 1 11.385 1 11.164 1 11.31 1 11.43
199 1 11.21 1 11.045 1 11.159 1 11.236
230 8 10.616 3 10.616 6 10.616 10 10.616
261 27 10.35 21 10.352 25 10.35 28 10.352
292 44 10.65 39 10.68 42 10.664 45 10.644
322 56 10.999 51 11.135 54 11.053 57 10.96
347 60 11.122 55 11.338 58 11.206 61 11.06
Yearly total 3963.52 3966.69 3966.12 3960.89

The difference between the four cities is very small less than 6 kWh in the whole year with Binban has maximum at 3966.69 kWh/m2/year and Matrough has the minimum at 3960.89 kWh/m2/year. Sues has maximum yearly radiation at 3963.52 kWh/m2/year. So, this means that most of the Egyptian cities have a high radiation level can reach 3960 kWh/m2/year.

Monthly altering of the TA (12 times in a year)

Since daily changing of the TA is difficult, costly, and it may be impractical to be implemented for PV panels, it is better to reduce the number of changing of the TA. In the present case, the TA is changed every month. The optimal monthly TA is computed depending on the monthly maximum sun radiation. For each month the tilt is changed from 0 to 90 degree, and then the angle of maximum radiation is determined. Table 2 displays the simulation results obtained for the present case in the same cities. For every month the OTA is calculated for the cities. Also, both the monthly total radiation and the daily average radiation are computed. The results are drawn in Fig. 7 which shows the total radiation for the four cities. The radiations for these cities are very near to each other. By comparing the total yearly radiation for this case and case two, one can discover that both cases have a near values. In the first case the yearly total SR in Suez city is 3963.52 kWh/m2, which is very near to the second case which is 3956.28 kWh. The total yearly radiation in this case is less than the first case by 7.24 kWh/m2 in all the year or 0.183% which is very small. This case shows a very important fact that varying the TA 12 times in a year is nearly equivalent to changing the TA 365 times or daily, thus no need to change the TA daily. Table 2 has been drawn in Fig. 7 which shows the monthly radiation for the four cities at monthly optimal angle.

Table 2.

Monthly radiation at monthly optimal angle.

City Suez Binban (Aswan) Sharm-Elshiekh Marsa Matrough
Month βopt Monthly rad kWh/m2 Av. daily Rad βopt Monthly rad kWh/m2 Av. daily Rad βopt Monthly rad kWh/m2 Av. daily Rad βopt Monthly rad kWh/m2 Av. daily rad
Jan 58 343.55 11.082 53 348.823 11.252 56 345.618 11.149 59 342.074 11.035
Feb 48 303.9 10.854 43 305.54 10.912 47 304.545 10.877 50 303.445 10.837
March 33 325.67 10.51 28 325.76 10.508 31 325.711 10.507 34 325.631 10.504
April 15 316.3 10.54 9 316.3 10.543 13 316.3 10.543 16 316.304 10.543
May 1 342.995 11.064 1 340.3 10.977 1 342.33 11.043 1 343.235 11.072
June 1 340.556 11.352 1 333.84 11.128 1 338.39 11.28 1 341.813 11.394
July 1 346.715 11.184 1 341.56 11.018 1 345.137 11.133 1 347.571 11.212
August 7 328.716 10.604 2 328.72 10.604 5 328.717 10.604 9 328.723 10.604
Sept 25 309.115 10.304 20 309.11 10.303 23 309.116 10.304 26 309.105 10.304
Oct 42 327.115 10.552 37 327.868 10.576 41 327.409 10.562 44 326.912 10.546
Nov 55 327.8 10.927 50 331.522 11.05 53 329.264 10.976 56 326.757 10.892
Dec 60 343.85 11.092 55 350.46 11.305 58 346.437 11.175 61 342.006 11.032
Total
 Case 3 3956.28 3959.80 3958.97 3953.58
 Case 2 3963.52 3966.69 3966.12 3960.89

Figure 7.

Figure 7

Solar radiation at monthly OTA for some cities in Egypt.

Variation of the TA 3 times per year (seasonally)

In this case the TA will be changed according to the season i.e. winter, spring, summer, and autumn. The first interval is the winter interval starting from 21st December to 20 of March of total 89 days. For Suez city, the OTA for this interval is computed in the same manner as in case 1 and 2, and it is found to be 51°, with total radiation in this period of 959.951 kWh/m2 and with daily average of 10.786 kWh/m2. The second interval includes spring days starting from 21st of March to 20 of June of total 93 days. The OTA is 6° with total SR of 993.634 kWh/m2 with daily average of 10.684 kWh/m2/day. In Summer season which starts from 22 June to 22 September, the OTA is 5° which is nearly identical to the spring season with total SR of 1000 kwh/m2 in 94 days with daily average of 10.638 kWh/m2/day. In Autumn which starts from 23 September till 20 December, the OTA is found to be equal to 50° which is also nearly equal to the winter season with total SR of 948.059 kWh/m2 in 89 days with daily average of 10.652 kWh/m2/day. The optimum angle and SR for the other cities are shown in Table 3.

Table 3.

The optimal angle and solar radiation for Case 3.

Season No. of days Suez
30°
Binban
24.44°
Shram-elsheikh
27.9654°
Matrough
31.3543°
βopt Radiation (kWh/m2/year) βopt Radiation (kWh/m2/year) βopt Radiation (kWh/m2/year) βopt Radiation (kWh/m2/year)
Winter 89 51 971.1024 47 979.90 49 974.6479 54 968.0599
Spring 93 6 993.634 1 993.6 4 993.635 7 993.612
Summer 94 5 1000 1 999.661 3 1000 6 1000
Autumn 89 50 948.059 45 955.9963 48 951.1984 51 945.813
Total 365 3912.795 3929.16 3919.48 3907.4849

By comparing the total yearly radiation of value 3901.6 kWh/m2 with case 2 that has a total yearly radiation of 3963.52 kWh/m2/year, one can notice that the difference is equal to 61.92 kWh/m2/year or + 1.56%. By comparison with the case three which has a value of 3956.28 kWh/m2/year the difference is 54.68 kWh/m2/year or + 1.38% which is small.

The most important outcome of this case is that, firstly varying the TA 4 times a year has a nearly equivalent to altering the TA 365 times a year or 12 times a year with an estimated error of 1.5%. The second outcomes can be noticed by checking the value of the OTA. From Table 3 one can notices that the winter OTA (which is 51° in winter) is approximately equal to the autumn OTA (which is 50° in autumn). So, one can use one TA for both autumn and winter seasons. Equal explanation can be used for spring and summer seasons. The result is only two OTAs are needed for the whole year with excellent accuracy.

Variation of the TA 2 times yearly

From the results obtained in case 3, one concludes that is only two OTAs are enough, since both the winter and autumn OTAs are very near, and both the spring and summer OTAs are very near. So, the year can be divided into two interval one for autumn and winter starting from 23rd of September till 20 of March of total of 178 days and the second interval include both spring and summer of total of 187 days starting from 20 of March to 22nd of September. By simulation these intervals for Suez city, one can find that the first interval has an optimal value of 50° and the other TA is 5°. The radiation is 3901.72 kWh/m2/year which is less than the second case by 61.8 kWh/m2/year or 1.56% in all the year which is very small. By comparing this case with case 3, one can see that this case is very near to case 3. So instead of changing the TA four times a year, it is easier and more economical to change it two times a year. Table 4 summarizes the OTA and radiation for the four cities.

Table 4.

Case 4: two optimal angles for the year.

Season No. of days Suez Binban Shram-elsheikh Matrough
βopt Radiation (kWh/m2/year) βopt Radiation (kWh/m2/year) βopt Radiation (kWh/m2/year) βopt Radiation (kWh/m2/year)
Winter + autumn 178 50 1908.26 46 1925.06 48 1914.916 51 1903.53
Summer + spring 187 5 1993.6 1 1993.3 3 1993.6 7 1993.6
Total 365 3901.86 3918.36 3908.52 3897.13

Comparing this case of two OTA with the commonly used two tilted angle method mentioned in several literature, which is using one TA in autumn and winter equal to Latitude angle + 15° and the other angle is equal to the Latitude angle − 15° in spring and summer. The optimal two angles of this case have a radiation of 3901.72 kWh/m2/year, while the common method has radiation of 3868.476 kWh/m2/year. As a result, this case is better with 3901.72–3868.476 = 33.2 kWh/m2/year which means + 0.86% higher than the two tilted angle method.

Fixed TA

In this case, the TA is kept fixed at an optimal yearly value. The OTA is calculated for Suez city and its value is equal to 28°, which is near to the latitude value. This is very common in practice to consider that the TA is identical to the latitude value. The total radiation in this case is 3620.3 kWh/m2/year, with an average daily of 9.9187 kWh/m2/day. Comparing this case with case 4, the difference between these two cases is 3901.72–3620.3 = 256.62 kWh/m2/year, or 7.77% which is not small. Comparing radiation computed at the OTA with the value of radiation computed at latitude angle which is 3619.2 kWh/m2/year. The radiation at the latitude TA is smaller than the radiation at the yearly OTA by 0.74% which is very small. Figure 8 shows the difference between the radiations at the two TAs.

Figure 8.

Figure 8

Comparisons between the radiation at OTA and the latitude angle.

Table 5 shows that the optimal yearly TA is very near to the latitude angle. The error between the two angles is very small and it is less than 0.03% and can be neglected from which, one can discover that the latitude angle can be used as a sub-OTA.

Table 5.

Shows the OTA for other cities in Egypt.

City Suez Binban Shram-Elshiekh Marsa-Matrough
Latitude 30° 24.44° 27.9654° 31.3543°
OTA 28° 23° 27° 30°
Yearly radiation kWh (optimal) 3620.3 3630.3 3624.3 3617.4
Yearly radiation kWh (latitude) 3619.2 3629.5 3623.4 3616.0
Difference between optimal and latitude 0.03% 0.022% 0.0248% 0.0387%

Experimental work

For experimental verification for the theoretical work, two PV systems directed towards south, with two TAs of 25°, and 30°, are constructed in Suez University (latitude 30°). Each system has 100 W PV panel, maximum power point tracker, inverter, battery, and load. The complete architecture of one scheme is displayed in Fig. 9. The measurements are recorded daily for 57 days, starting from 4th of April till 30 of May. Some of the measurements are shown in Table 6 which shows the actual meter pictures in columns 3 and 5 for the 25° and 30° TAs systems respectively. These reading are rewritten in numbers in columns 4 and 6 for both systems. The measurements are shown in Fig. 10 which shows that the energy consumed for both systems in exactly 57 days which are shown in the horizontal axis by day number starting from the fourth of April (or day number 94) and ending at day 30 of May (or day number 150). In this period, the net energy consumed by the 25° TA system is equal to 13.9 kWh, with average daily consumption of 0.243 kWh. The 30° systems consumed energy of 13.3 kWh with average daily energy of 0.233 kWh/m2/day. The 25° TA is higher the 30° by an energy of 0.6 kWh or 4.4%. This agrees with the theoretical results obtained in case 2 which showed that the TAs in these months which are 15° (not very far from 25°) for April and 1° (which is very far from 30°) for May. Also from Fig. 8 and for months April and May, one can easily notice that the SR in these two months for 25° TL is higher than that of the 30°. Figure 10 shows this result with a small difference between the two systems.

Figure 9.

Figure 9

The system components and experimental setup for 25° TA.

Table 6.

Readings of the two TAs PV systems.

Date Temp. (°C) 25° TA system 30° TA system
Meter reading Reading Meter reading Reading
4/4 36 graphic file with name 41598_2023_30375_Figa_HTML.gif 2.3 graphic file with name 41598_2023_30375_Figb_HTML.gif 1.8
10/4 36 graphic file with name 41598_2023_30375_Figc_HTML.gif 3.8 graphic file with name 41598_2023_30375_Figd_HTML.gif 3.1
16/4 35 graphic file with name 41598_2023_30375_Fige_HTML.gif 5.5 graphic file with name 41598_2023_30375_Figf_HTML.gif 4.8
20/4 36 graphic file with name 41598_2023_30375_Figg_HTML.gif 6.8 graphic file with name 41598_2023_30375_Figh_HTML.gif 5.7
26/4 35 graphic file with name 41598_2023_30375_Figi_HTML.gif 8.4 graphic file with name 41598_2023_30375_Figj_HTML.gif 7.3
28/4 36 graphic file with name 41598_2023_30375_Figk_HTML.gif 7.7 graphic file with name 41598_2023_30375_Figl_HTML.gif 8.8
7/5 36 graphic file with name 41598_2023_30375_Figm_HTML.gif 10.9 graphic file with name 41598_2023_30375_Fign_HTML.gif 9.9
10/5 38 graphic file with name 41598_2023_30375_Figo_HTML.gif 11.6 graphic file with name 41598_2023_30375_Figp_HTML.gif 10.6
15/5 38 graphic file with name 41598_2023_30375_Figq_HTML.gif 12.8 graphic file with name 41598_2023_30375_Figr_HTML.gif 11.7
19/5 38 graphic file with name 41598_2023_30375_Figs_HTML.gif 13.6 graphic file with name 41598_2023_30375_Figt_HTML.gif 12.6
25/5 40 graphic file with name 41598_2023_30375_Figu_HTML.gif 15.0 graphic file with name 41598_2023_30375_Figv_HTML.gif 13.9
30/5 39 graphic file with name 41598_2023_30375_Figw_HTML.gif 16.2 graphic file with name 41598_2023_30375_Figx_HTML.gif 15.1

Figure 10.

Figure 10

Energy consumed by both systems during the period starting from 4th of April to 30 of May.

Human and animal rights

This article does not contain any studies with animals performed by any of the authors.

Conclusions

This paper investigates the optimum TA for PV panels. The OTA for each day is calculated for some cities in Egypt. Although the optimum daily TA produces the highest SR value, but it may not be practical for PV panels. It can be used in some other application for example solar cookers. Also, both the optimal monthly and seasonal TAs are calculated for these cities in Egypt. After that the optimal yearly tow TAs are calculated for the whole year. The final case calculates one OTA for all the year which is very close to the latitude angle. From the results it has been shown that, although, the optimal daily angles give the best solar radiation, but it is not practical for PV panels. For practical standpoint, the best way is to use the two OTAs in the year since it gives a SR that is very near to the daily OTAs. Comparing the two OTAs presented here with the commonly used method which use a TAs equal to Latitude angle + 15° for autumn and winter months and the other angle is the Latitude angle – 15° for spring and summer months. When simulating this method, the two OTAs presented in this paper calculated at TAs of 5° for spring and summer months and 50° for winter months for Suez city, this method gives SR of 3901.72 kWh/year/m2 which is higher that the commonly used two TAs method. A fixed TA can be used, but the SR will be lower than the two optimal angels’ method. An experimental work has been done on two small PV systems, the first one is at a TA of 30° (latitude angle of Suez), the other value of TA is 25°. Measurements have been recorded during April and May. The Measurements show that for that period the TA of 25° is better than of the 30° TA by 4.4% which is coincidence with the theoretical results.

Author contributions

A.K.A.: Data curation, Conceptualization, Methodology, Software, Writing-Original draft preparation, Practical measurements, Visualization, Software, Investigation. A.A.E.: Formal analysis, Writing-Reviewing and Editing, Supervision, Validations of Results. The authors read and approved the final manuscript.

Funding

Open access funding provided by The Science, Technology & Innovation Funding Authority (STDF) in cooperation with The Egyptian Knowledge Bank (EKB).

Data availability

The data that support the findings of this study are available from the corresponding author upon reasonable request.

Competing interests

The authors declare no competing interests.

Footnotes

Publisher's note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

References

  • 1.Fouad M, Shihata LA, Morgan EI. An integrated review of factors influencing the performance of photovoltaic panels. Renew. Sustain. Energy Rev. 2017;80:1499–1511. doi: 10.1016/j.rser.2017.05.141. [DOI] [Google Scholar]
  • 2.Hosenuzzaman, M. Rahim, N. A., Selvaraj, J. & Hasanuzzaman, M. Factors affecting the PV based power generation. In 3rd IET International Conference on Clean Energy and Technology (CEAT) (2014) 10.1049/cp.2014.1467.
  • 3.Nemet GF, O’Shaughnessy E, Wiser R, Darghouth NR, Barbose G, Gillingham K, Rai V. What factors affect the prices of low-priced U.S. solar PV systems? Renew. Energy. 2017;114:1333–1339. doi: 10.1016/j.renene.2017.08.018. [DOI] [Google Scholar]
  • 4.Zamora NMR. Optimal tilt angle for solar photovoltaic modules on pitched rooftops: A case of low latitude equatorial region. Sustain. Energy Technol. Assess. 2022;50:101821. doi: 10.1016/j.seta.2021.101821. [DOI] [Google Scholar]
  • 5.Agrawal M, Chhajed P, Chowdhury A. Performance analysis of photovoltaic module with reflector: Optimizing orientation with different tilt scenarios. Renew. Energy. 2022;186:10–25. doi: 10.1016/j.renene.2021.12.149. [DOI] [Google Scholar]
  • 6.Shariah A, Al-Akhras M, Al-Omari IA. Optimizing the tilt angle of solar collectors. Renew. Energy. 2002;26(4):587–598. doi: 10.1016/S0960-1481(01)00106-9. [DOI] [Google Scholar]
  • 7.Osmani K, Ramadan M, Lemenand T, Castanier B, Haddad A. Optimization of PV array tilt angle for minimum levelized cost of energy. Comput. Electr. Eng. 2021;96:107474. doi: 10.1016/j.compeleceng.2021.107474. [DOI] [Google Scholar]
  • 8.Liu Y, Yao L, Jiang H, Lu N, Qin J, Liu T, Zhou C. Spatial estimation of the optimum PV tilt angles in China by incorporating ground with satellite data. Renew. Energy. 2022;189:1249–1258. doi: 10.1016/j.renene.2022.03.072. [DOI] [Google Scholar]
  • 9.Umunnakwe A, et al. Modeling and estimation of the optimal tilt angle, maximum incident solar radiation, and global radiation index of the photovoltaic system. Heliyon. 2022;8(6):e09598. doi: 10.1016/j.heliyon.2022.e09598. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 10.Karinka S, Upadhyaya V. Concept of annual solar window and simple calculation for optimal monthly tilt angle to maximize solar power generation. Mater. Proc. 2022;52:2166–2171. doi: 10.1016/j.matpr.2021.12.594. [DOI] [Google Scholar]
  • 11.Abdallah R, Juaidi A, Salameh T, Jeguirim M, Çamur H, Kassem Y, Abdala S. Estimation of solar irradiation and optimum tilt angles for south-facing surfaces in the United Arab Emirates: A case study using PVGIS and PVWatts. Recent Adv. Renew. Energy Technol. 2022;2:3–39. doi: 10.1016/B978-0-12-823532-4.00004-5. [DOI] [Google Scholar]
  • 12.Xu L, Long E, Wei J, Cheng Z, Zheng H. A new approach to determine the optimum tilt angle and orientation of solar collectors in mountainous areas with high altitude. Energy. 2021;237:121507. doi: 10.1016/j.energy.2021.121507. [DOI] [Google Scholar]
  • 13.Yadav S, Hachem-Vermette C, Panda SK, Tiwari GN, Mohapatraa SS. Determination of optimum tilt and azimuth angle of BiSPVT system along with its performance due to shadow of adjacent buildings. Sol. Energy. 2021;215:206–219. doi: 10.1016/j.solener.2020.12.033. [DOI] [Google Scholar]
  • 14.Sharma A, Ali Kallioğlu M, Chauhan AAR, Fekete G, Singh T. Correlation formulation for optimum tilt angle for maximizing the solar radiation on solar collector in the Western Himalayan region. Case Stud. Thermal Eng. 2021;26:101185. doi: 10.1016/j.csite.2021.101185. [DOI] [Google Scholar]
  • 15.Awasthi A, Kallioğlu MA, Sharma A, Mohan A, Chauhan R, Singh T. Solar collector tilt angle optimization for solar power plant setup-able sites at Western Himalaya and correlation formulation. J. Thermal Anal. Calorim. 2022;147:11417–11431. doi: 10.1007/s10973-022-11345-0. [DOI] [Google Scholar]
  • 16.Hassan Q, Abbas MK, Abdulateef AMAJ, Mohamad A. Assessment the potential solar energy with the models for optimum tilt angles of maximum solar irradiance for Iraq. Case Stud. Chem. Environ. Eng. 2021;4:100140. doi: 10.1016/j.cscee.2021.100140. [DOI] [Google Scholar]
  • 17.Mansour RB, MateenKhan MA, Alsulaiman FA, Mansour RB. Optimizing the solar PV tilt angle to maximize the power output: A case study for Saudi Arabia. EEE Access. 2021;9:15914–15928. doi: 10.1109/access.2021.3052933. [DOI] [Google Scholar]
  • 18.Tiris M, Tiris Ç. Optimum collector slope and model evaluation: Case study for Gebze, Turkey. Energy Convers. Manag. 1998;39(3–4):167–172. doi: 10.1016/S0196-8904(96)00229-4. [DOI] [Google Scholar]
  • 19.Sarr A, Kebe CMF, Ndiaye A. Determination of the optimum tilt angle for photovoltaic modules in Senegal. Afr. J. Environ. Sci. Technol. 2021;15(6):214–222. doi: 10.5897/AJEST2021.2988. [DOI] [Google Scholar]
  • 20.Shaker Al-Sayyab AK, Tmari ZYA, Taher MK. Theoretical and experimental investigation of photovoltaic cell performance, with optimum tilted angle: Basra city case study. Case Stud. Thermal Eng. 2019;14:100421. doi: 10.1016/j.csite.2019.100421. [DOI] [Google Scholar]
  • 21.Wei C-C. Predictions of surface solar radiation on tilted solar panels using machine learning models: A case study of Tainan City, Taiwan. Energies. 2017;10:1660. doi: 10.3390/en10101660. [DOI] [Google Scholar]
  • 22.Demain C, Journée M, Bertrand C. Evaluation of different models to estimate the global solar radiation on inclined surfaces. Renew. Energy. 2012;50:710–721. doi: 10.1016/j.renene.2012.07.031. [DOI] [Google Scholar]
  • 23.Namrata K, Sharma SP, Saksena SBL. Comparison of different models for estimation of global solar radiation in Jharkhand (India) region. Smart Grid Renew. Energy. 2013 doi: 10.4236/sgre.2013.44041. [DOI] [Google Scholar]
  • 24.Qasaimeh A, Qasaimeh M, Abu-Salem Z, Momani M. Solar energy sustainability in Jordan. Comput. Water Energy Environ. Eng. 2014;3(2):41–47. doi: 10.4236/cweee.2014.32006. [DOI] [Google Scholar]
  • 25.Li DHW, Lam TNT. Determining the optimum tilt angle and orientation for solar energy collection based on measured solar radiance data. Int. J. Photoenergy. 2007;2007:085402. doi: 10.1155/2007/85402. [DOI] [Google Scholar]
  • 26.Islam MA, Alam MdS, Sharker KK, Nandi SK. Estimation of solar radiation on horizontal and tilted surface over Bangladesh. Comput. Water Energy Environ. Eng. 2016;5(2):54–69. doi: 10.4236/cweee.2016.52006. [DOI] [Google Scholar]
  • 27.Benghanem M. Optimization of tilt angle for solar panel: Case study for Madinah, Saudi Arabia. Appl. Energy. 2011;88(4):1427–1433. doi: 10.1016/j.apenergy.2010.10.001. [DOI] [Google Scholar]
  • 28.Calabr E. An algorithm to determine the optimum tilt angle of a solar panel from global horizontal solar radiation. J. Renew. Energy. 2013;2013:307547. doi: 10.1155/2013/307547. [DOI] [Google Scholar]
  • 29.Ahmad A, Okoye CO, Atikol U. The effect of latitude on the performance of different solar trackers in Europe and Africa. Appl. Energy. 2016;177:896–906. doi: 10.1016/j.apenergy.2016.05.103. [DOI] [Google Scholar]
  • 30.Alatarawneh IS, Rawadieh SI, Tarawneh MS, Alrowwad SM, Rimawi F. Optimal tilt angle trajectory for maximizing solar energy potential in Ma’anareain in Jordan. J. Renew. Sustain. Energy. 2016;8:033701. doi: 10.1063/1.4948389. [DOI] [Google Scholar]
  • 31.Khorasanizadehm H, Mohammadi K, Mostafaeipour A. Establishing a diffuse solar radiation model for determining the optimum tilt angle of solar surfaces in Tabass Iran. Energy Convers. Manage. 2014;78:805–814. doi: 10.1016/j.enconman.2013.11.048. [DOI] [Google Scholar]
  • 32.Jafarkazemi F, Saadabadi SA. Optimum tilt angle and orientation of solar surfaces in Abu Dhabi, UAE. Renew. Energy. 2013;56:44–49. doi: 10.1016/j.renene.2012.10.036. [DOI] [Google Scholar]
  • 33.Darhmaoui H, Lahjouji D. Latitude based model for tilt angle optimization for solar collectors in the mediterranean region. Energy Procedia. 2013;42:426–435. doi: 10.1016/j.egypro.2013.11.043. [DOI] [Google Scholar]
  • 34.Kecili I, Nebbali R, Saada SA. Optimal tilt angle of a solar panel for a wide range of latitudes: Comparison between tilted and horizontal configurations. Int. J. Ambient Energy. 2022 doi: 10.1080/01430750.2022.2101522. [DOI] [Google Scholar]
  • 35.Salari M, Javaran EJ. Optimising the tilt angle for solar surfaces using different solar irradiation models in Yazd. Iran Int. J. Ambient Energy. 2018 doi: 10.1080/01430750.2017.1303633. [DOI] [Google Scholar]
  • 36.Ahmad MJ, Tiwari GN. Optimum tilt angle for solar collectors used in India. Int. J. Ambient Energy. 2009 doi: 10.1080/01430750.2009.9675788. [DOI] [Google Scholar]
  • 37.Abed F, Al-Salami QH. Calculate the best slope angle of photovoltaic panels theoretically in all cities in Turkey. Int. J. Environ. Sci. Technol. 2022;19:9639–9654. doi: 10.1007/s13762-021-03797-y. [DOI] [Google Scholar]
  • 38.Duffie JA, Beckman WA, Blair N. Solar Engineering of Thermal Processes, Photovoltaics and Wind. 5. Wiley; 2020. [Google Scholar]
  • 39.http://solardat.uoregon.edu/PolarSunChartProgram.php. Accessed 23 Sept 2022.