Piezoelectric atomization of liquids with dynamic viscosities up to 175 cP at room temperature

Tang Xie 1,1, Yaohua Zeng 1,1, Zhenzhen Gui 1, Mingdong Ma 1, Yuxuan Huo 1, Weirong Zhang 1, Tian Tan 1, Tao Zou 1,, Fan Zhang 1,, Jianhui Zhang 1,
PMCID: PMC9975313  PMID: 36801672

Highlights

  • The proposed structure enables atomization of liquids with a dynamic viscosity up to 175 cP at room temperature.

  • Using multi-dimensional vibration coupling to overcome the lack of energy density per unit of traditional ultrasonic atomizers.

  • The coupled vibrations can cause micro-amplitude elliptical motion to push the liquid forward and cause cavitation effects inside the liquid.

  • Using Laser Doppler Vibrometer to demonstrate that coupled vibrations cause micro-amplitude elliptical motion.

  • Spectroscopic experiments demonstrate the cavitation of the liquid during the atomization process and the unchanged chemical properties of the atomized liquid.

Keywords: Piezoelectric atomization, High viscosity, Vibration coupling, Elliptic motion, Cavitation effect, Raman spectroscopy

Abstract

Piezoelectric atomization has been applied in the field of respiratory medicine delivery and chemistry. However, the wider application of this technique is limited by the viscosity of the liquid. High-viscosity liquid atomization has great potential for applications in aerospace, medicine, solid-state batteries and engines, but the actual development of atomization is behind expectations. In this study, instead of the traditional model of single-dimensional vibration as a power supply, we propose a novel atomization mechanism that uses two coupled vibrations to induce micro-amplitude elliptical motion of the particles on the surface of the liquid carrier, which produces a similar effect as localized traveling waves to push the liquid forward and induce cavitation to achieve atomization. To achieve this, a flow tube internal cavitation atomizer (FTICA) consisting of a vibration source, a connecting block and a liquid carrier is designed. The prototype can atomize liquids with dynamic viscosities up to 175 cP at room temperature with a driving frequency of 507 kHz and a voltage of 85 V. The maximum atomization rate in the experiment is 56.35 mg/min, and the average atomized particle diameter is 10 µm. Vibration models for the three parts of the proposed FTICA are established, and the vibration characteristics and atomization mechanism of the prototype were verified using the vibration displacement measurement experiment and the spectroscopic experiment. This study offers new possibilities for transpulmonary inhalation therapy, engine fuel supply, solid-state battery processing and other areas where high-viscosity microparticle atomization is needed.

1. Introduction

Atomization is the process by which a continuous liquid is dispersed into a two-phase flow of small particle droplets. Ultrasonic atomization refers to an atomization process where an ultrasonic atomizer applies a driving frequency higher than 20 kHz. In general, the higher the driving frequency is, the smaller the atomized particles [1]. Most of ultrasonic atomizers operate in the piezoelectric driving mode, as this mode yields low energy consumption, high efficiency, simple structure, small atomized particles and low cost [2], [3], [4], [5]. Therefore, ultrasonic atomizers are widely used in the aerospace and medical fields, engines, solid-state batteries, food, and environmental improvement and quality of life improvement applications [6], [7], [8].

The first study on ultrasonic atomization was carried out by Wood and Loomis [9]. Afterward, the ultrasonic atomization industry developed at a high speed. Currently, there are three main types of ultrasonic atomizers, namely, surface acoustic wave (SAW) atomizers [10], [11], [12], static mesh atomizers [13], [14], [15] and dynamic mesh atomizers [16], [17], [18], which are widely used for the conventional atomization of water, liquid fuels and detergents [19], [20], [16], [21], [22].

In recent years, various milestones have been reached due to the rapid development of research on ultrasonic atomization. Particularly in the fields of pharmaceutical inhalation therapy, fuel injection and solid-state batteries, ultrasonic atomizers have great potential for application. For upper respiratory tract and pulmonary diseases, inhalation therapy allows direct access to the affected area, significantly reduces medicine dosage required, and reduces side effects and adherence compared to those of traditional oral and intravenous medicine administration [23], [24]. For fuel injection atomization, ultrasonic atomization not only consumes less energy than conventional pressure atomization but also yields smaller atomized particles, thereby allowing the fuel to burn more fully and reducing the harm to the environment from combustion products. For solid-state batteries, binders are used to bond the electrode material to the current collector and are usually present in less than 10% of electrodes [25]. The current commonly used process is mixing the binder with various electrode materials, enabling the electrode materials to be bonded together [26], [27]. A few processes use pressure to atomize the binder and to spray it onto the electrode material. Compared to the method of mixing the binder and the electrode material, this atomization combination method yields smaller liquid binder particles, which allows a more uniform combination of the two, ultimately increasing the conductivity of the electrodes and improving the performance of the battery.

All three of the atomizer structures are used in the field of inhalation therapy. However, the viscosity of the liquid must be less than 7 cP [28], significantly limiting the variety of inhaled medicines and hindering the development of inhalation therapy with high-viscosity medicines, including herbs. Therefore, the study of high-viscosity liquid atomization for medical inhalation therapy has important significance and broad development prospects.

The viscosity of the fuel used in an engine is generally approximately 4 cP [29], [30], and the current approach is to use ultrahigh pressure, up to 1500 bar, for atomization of high-viscosity liquids [31], [32]. However, achieving high injection pressures requires very large amounts of energy, which is contrary to the original reason for atomizing fuel, reducing particle size and increasing combustion efficiency. Therefore, studying the atomization of high-viscosity liquids is important for improving engine combustion efficiency, reducing energy consumption and reducing carbon emissions.

The pressure atomization method used in solid-state batteries allows the bonding of the binder with the active material. Although this method of bonding allows more uniform bonding, the binder has a very high viscosity, of several thousand or even tens of thousands of centipoises [33], so pressure atomization requires very high energy consumption, and the atomization particle size is not sufficiently small, which affects the bonding uniformity. Therefore, the study of the atomization of high-viscosity liquids by ultrasonic atomization will provide important alternative ideas in the field of solid-state batteries processing.

Researchers have explored the piezoelectric atomization of highly viscous liquids. In 2010, A. Lozano et al. used a piezoelectric ceramic disc structure to achieve ultrasonic atomization of liquids with a kinematic viscosity of 28 cSt [34]. In 2017, Junhui Law et al. implanted a microheater into an atomization device to achieve atomization of liquids with viscosities of 1 cP − 200 cP, using heating to generate large amounts of gas nuclei [35]. However, heat could destroy or degrade medicines, and the design is too complex to be used in the pharmaceutical field. In 2021, Axel Lefebure et al. designed an apparatus with a fibrous liquid delivery column at the lower end of a grid atomizer to atomize a high-viscosity biodegradable oil with a kinematic viscosity of 37 cSt (dynamic viscosity of approximately 30 cP), representing the highest viscosity liquid atomized at room temperature to date [36].

With the current ultrasonic atomizers, when liquid viscosity increases from 1 cP to 100 cP, the unit atomization energy increases tens or even hundreds of times, posing an extreme challenge of the traditional atomization mechanism and structure. This study does not employ the idea of increasing energy density in the traditional structure to achieve atomization of high-viscosity liquids but rather overcomes the limitation of using one single-dimensional vibration as the atomization actuation power source in the traditional structure. Based on the above principle, we propose a novel FTICA with two dimensions of vibration synthesis for actuation and use cavitation caused by vibration to achieve liquid atomization.

The novel FTICA proposed in this study was inspired by the ultrasonic motor principle [37]. An ultrasonic motor uses two vibrations of the same frequency and different phases perpendicular to each other, so the surface particles of the stator of the ultrasonic motor form an elliptical trajectory, thus driving an object to move by friction [38]. Due to its simple structure, small size, light weight, fast response time, low noise level, large torque at low speed, good control characteristics, self-locking characteristic under power failure, freedom from magnetic field interference, and accurate motion [39], [40], ultrasonic motors are widely used in the automotive, aerospace, precision manufacturing, optical scanning, biotechnology and medicine [41], [42], [43], [44], [45], [46], [47], and energy harvesting fields [48], [49], [50], [51].

By working principle, ultrasonic motors can be divided into three main categories [52], [53]: traveling wave type [54], [55], standing wave type [56], [57] and composite type [58], [59]. However, all these studies address the movement of only solids and are rarely used in the field of liquid atomization.

In this study, the use of coupled longitudinal vibration and bending vibration as the actuation force is proposed as an alternative to the use of traditional one-dimensional vibration, and this idea is combined with cavitation theory to design a novel FTICA structure that can atomize liquids with viscosities up to 175 cP at room temperature. The proposed design uses a single piezoelectric driving source to generate longitudinal vibration and bending vibration at the same time. The two couple to form micro-amplitude elliptical motion, on the one hand, to drive the liquid forward, and on the other hand, to cavitate the liquid to achieve atomization. In this study, the vibration model of each part was established for the proposed coupled FTICA structure, and a set of theoretical solutions were obtained at a frequency of 507 kHz. A prototype was designed and built, and atomization experiments were conducted using liquids with viscosities of 50–175 cP to verify the feasibility of the FTICA design. The vibration displacements of each component of the FTICA were measured using a three-dimensional Doppler vibrometer to verify the correctness of the theoretical model. Full-spectrum experiments and Raman spectroscopy experiments were designed to verify the feasibility of the cavitation theory. This study provides a new atomization mechanism and atomization structure to address the problem of the ultrasonic atomization of high-viscosity liquids, providing a new direction for inhalation therapy, engine fuel atomization, solid-state batteries, aromatic essential oils and other applications that depend on high-viscosity liquids.

2. Material and methods

2.1. The structure of FTICA

Fig. 1 shows the structure of the FTICA in this study, which was composed of a vibration source, a connecting block and a liquid carrier, and the vibration source consists of a piezoelectric ceramic and a metal base. The piezoelectric ceramic was made of PZT, and the other structures were made of 304 stainless steel. The piezoelectric ceramic was under the vibration source, and the upper and lower ends of the connecting block were connected to the vibration source and the liquid carrier by welding. The main parameters of the FTICA are shown in Fig. 1(b) and Table 1, and a photograph of the prototype is shown in Fig. 1(c).

Fig. 1.

Fig. 1

Structure of the FTICA: (a) Three-dimensional structure; (b) Two-dimensional cross-section; (c) Photograph of the prototype.

Table 1.

Main dimensional values of the FTICA.

Parameters Values
Diameter/d0 (mm) 18.00
Thickness/h0 (mm) 1.00
Diameter/d1 (mm) 24.00
Thickness/h1 (mm) 4.00
Height/b2 (mm) 36.00
Thickness/h2 (mm) 1.00
Height/b3 (mm) 46.00
Diameter/D3 (mm) 1.00
Diameter/d3 (mm) 0.80
Distance/l3 (mm) 45.00
Distance/l31 (mm) 10.00

2.2. Ratio of liquid viscosity and analysis of impedance

In this experiment, propylene glycol liquid (with a dynamic viscosity of approximately 50 cP at room temperature) and vegetable glycerin liquid (with a dynamic viscosity of approximately 700 cP at room temperature) were used as the base liquids and were mixed according to the ratios shown in Table 2. The actual viscosities were measured using a rotary viscometer (NDJ-1, LICHEN, Shanghai, China) and are shown in Fig. 2(a).

Table 2.

Mixing ratio of liquid for atomization.

Propylene Glycol share Vegetable Glycerin share Actual measured viscosity (cP)
100% 0% 50
88.2% 11.8% 75
76.1% 23.9% 100
69.2% 30.8% 125
62.3% 37.7% 150
56.5% 43.5% 175

Fig. 2.

Fig. 2

Preliminary experiment: (a) Configuration diagram for different viscosity liquids; (b) Diagram of the experimental setup for impedance analysis.

To initially determine the resonance points for subsequent atomization experiments, an impedance analyzer (LCR Meter 6630, MICROTEST, Taiwan, China) was used to analyze the impedance of the whole FTICA. The experimental setup is shown in Fig. 2(b).

2.3. Measurement of atomization rate and atomized particle sizes

To verify the atomization effect of the FTICA proposed in this study, measurements of the atomization rate were carried out; the experimental system is shown in Fig. 3(a). The atomization rate was obtained using a precision analytical balance (FA2204, LICHEN, Shanghai, China) to measure the mass of the liquid reservoir bottle before and after atomization and a peristaltic pump to deliver of the liquid.

Fig. 3.

Fig. 3

Diagram of atomization experimental setup: (a) Diagram of atomization rate experimental setup; (b) Diagram of the experimental setup for particle size testing.

The atomized particle diameters and their distributions were measured using a spray laser particle size analyzer (Winner311XP, Winner Particle, Jinan, China); the experimental setup is shown in Fig. 3(b).

2.4. Experiments of vibration measurement

Vibration displacement measurements of the three-part structure of the FTICA were carried out using two types of laser Doppler measuring vibration instruments. Due to the large vibration area of the vibration source and the Connecting Body, a three-dimensional scanning laser (LV-SC400, SOPTOP, Zhejiang, China) was used to measure the displacements. Fig. 4(a) - Fig. 4(b) shows the displacement measurement setup.

Fig. 4.

Fig. 4

Diagram of the displacement measurement setup: (a) Diagram of the vibration experimental setup for the vibration source; (b) Diagram of the vibration experimental setup for the Connecting Body; (c) Diagram of the vibration experimental setup for the liquid carrier; (c’) Overall experimental setup; (c’’) FTICA fluid supply system; (c’’’) Displacement stage partial enlargement.

Due to the small diameter of the liquid carrier, a single-point laser vibrometer (LV-S01, SOPTOP, Zhejiang, China) was selected, coordinating with a precision displacement stage. The displacement of the bending vibration in the liquid carrier diameter direction and longitudinal vibration in the axis direction were measured; the experimental setup is shown in Fig. 4(c).

2.5. Experiments of spectral measurement

Raman spectroscopy was used to verify whether the molecular structure of the liquid changes from before to after atomization. The experimental setup for the microscopic Raman spectroscopy (ATR8300, OPTOSKY, Fujian, China) is shown in Fig. 5(a).

Fig. 5.

Fig. 5

Diagram of spectroscopy experimental setup: (a) Diagram of the experimental setup for micro-Raman spectroscopy; (b)Diagram of the spectral absorbance experimental setup; (b’) Overall experimental setup; (b’’) Enlarged view of the optical fiber connection; (b’’’) Schematic diagram of the optical fiber connection.

A high-power light source transmitter and receiver (ATG1100, OPTOSKY, Fujian, China) was used to analyze the absorbance and light intensity of the liquid before and after atomization. The experimental setup for the absorption spectroscopy measurements is shown in Fig. 5(b).

3. Theory and calculation

3.1. Theory of liquid movement

According to the theory of dynamics, if a particle vibrates with the same frequency and different phases in two mutually perpendicular directions, the trajectory of the particle is an ellipse. Currently, this motion is known as elliptical motion. For the liquid carrier, if all the particles on the tube wall undergo micro-amplitude elliptical motion, the liquid inside the liquid carrier moves due to contact with the moving particles. Therefore, the analysis of liquid movement theory translates into the analysis of the micro-amplitude elliptical motion of a particle on the tube wall.

We designed a vibration source consisting of a piezoelectric ceramic and a metal base, and we used an eccentrically mounted connecting block to achieve orthogonal vibrations of the same frequency and different phases and to ultimately achieve propulsion and atomization of the liquid in the liquid carrier. Carrying out a vibration transfer analysis of the whole FTICA would be very complex and impractical, so we split the whole FTICA into three parts for vibration transfer analysis according to the different parts of the structure: vibration source vibration analysis, connecting block vibration analysis and liquid carrier vibration analysis.

For clear and unambiguous vibration analysis of the three parts, it is necessary to establish separate coordinate systems for each part. Fig. 6 shows the establishment of the coordinate systems for each part. To keep the established coordinates clear, we use subscripts to represent the parameters in the coordinate system. Xij denotes the X coordinate of the j-th variable in the i-th structure, wherei=1,2,3. For example, we refer to X30 in section 3.1.3 of the paper meaning a variable in the third structure (liquid carrier). The structure of the FTICA is shown in Fig. 6(a). The simplified circular thin plate coordinate system of the vibration source is set too1-r1-θ1-z1, and the eccentricity of the circular thin plate coordinate origin and the connecting block coordinate origin ise12, as shown in Fig. 6(b). The connecting block coordinate system is set aso2-x2-y2-z2, as shown in Fig. 6(c). We set the liquid carrier coordinate system as o3-x3-y3-z3 and the eccentricity between the connecting block coordinate origin and the liquid carrier coordinate origin ase23, as shown in Fig. 6(d). Moreover, the magnitude and direction of the force in the forced vibration are indicated for each part in the upper right corners of Fig. 6(b), Fig. 6(c) and Fig. 6(d), respectively. Note that the component forces along the y2 direction are not represented for the connecting block, as only bending vibrations are considered and not vibrations along the y2 direction.

Fig. 6.

Fig. 6

Coordinate systems for each part: (a) Overall atomizer; (b) Vibration source coordinate system; (c) Connecting block coordinate system; (d) Liquid carrier coordinate system.

3.1.1. Vibration analysis of the vibration source

The vibration source model can be simplified to a circular thin plate with fixed supports all around, where the radius isa1, the thickness ish1, the material density isρ1, the modulus of elasticity is E1 and the Poisson ratio isμ1, as shown in Fig. 6(b). Using the relationship between the polar coordinates r1 andθ1, and the Cartesian coordinates x1 andz1, the partial differential equation for the displacement of a circular thin plate can be expressed as [60], [61], [62], [63]:

2w1t12+(D1ρ1h1)2(2r12+1r1r12+1r122θ12)2w1=0 (1)

where D1=E1h13121-μ12 is the bending stiffness of the plate, and w1 is the vibrational displacement.

Due to the symmetry of the circular thin plate, the above equation can be solved as [63]:

w1(r1,θ1,t1)=R(r1)(Sn1sinn1θ1+En1cosn1θ1)eiωat1 (2)

where ωa is the natural frequency of the circular thin plate, Rr1Sn1sinn1θ1 and Rr1En1sinn1θ1 are the basis functions that form the function space.

For a circular thin plate with fixed perimeter support, the boundary conditions can be expressed as [60]:

Ra1=0,Ra1=0 (3)

Using boundary conditions, the natural frequency of the circular thin plate can be found, which is expressed as:

ωa=ωm1n1=λm1n1a12D1ρ1h1 (4)

where m1 denotes the number of nodal circles; n1 indicates the number of nodal diameters; and λm1n1 indicates the natural frequency constant.

Thereby, the mode function of the circular thin plate can be obtained, which is expressed as:

Φm1n1r1,θ1=An1Jn1k1r1-Jn1λm1n1In1λm1n1In1k1r1Sn1sinn1θ1+En1cosn1θ1 (5)

wherek14=ωa2ρ1h1D1.

At this point, the forced vibration of the circular thin plate can be analyzed in terms of the mode function and the natural frequency. As shown in Fig. 6(b), the distributed excitation force of the piezoelectric ceramic acting on a uniform thin plate with frequency ω0 isfar1,θ1,t1=Far1,θ1eiω0t1. This distributed excitation force can be derived from the piezoelectric equation [60].

The following is a method for determining the forced vibration response of the circular thin plate using distributed excitation force. The displacement response of a thin plate to forced vibration with small deflection is expressed using the normalized displacement modes of each order of the plate as [60], [61], [62]:

w2r1,θ1,t1=m1=0n1=0Φm1n1r1,θ1qm1n1t1 (6)

where Φm1n1r1,θ1 is the normalized displacement mode of each order of the thin plate and satisfies the orthogonality condition for the thin plate vibration mode. qm1n1t2 corresponds to the generalized coordinates ofΦm1n1r1,θ1.

Using excitation force, we can obtain the displacement deflection forcing response of a uniformly thin plate:

w2r1,θ1,t1=m1=0n1=0Fm1n1Φm1n1r1,θ1eiω0t1-φm1n1Km1n11-ω¯m1n122+2ξm1n1ω¯m1n12 (7)

where ω¯m1n1=ω0ωm1n1 is the ratio of the excitation frequency to the natural frequency of the system vibration, ξm1n1=C2Mm1n1ωm1n1 is the relative damping factor of the system, C is the damping, and φm1n1=tan-12ξm1n1ω¯m1n11-ω¯m1n12 is the phase of the system.

Whenω0=ωm1n1, the circular thin plate is in resonance of orderm1n1, and the displacement deflection forcing response is mainly of orderm1n1. Therefore, the displacement deflection forcing response can be expressed as:

w2r1,θ1,t1=Fm1n1Φm1n1r1,θ1eiω0t1-φm1n1Km1n11-ω¯m1n122+2ξm1n1ω¯m1n12 (8)

After finding the forced response of displacement deflection at resonance, we use the displacement deflection forcing response function w2r1,θ1,t1 to find the second order partial derivative for timet1. Thereby, the acceleration of the vibration source at any point in the vibration mode can be obtained:

2w2r1,θ1,t1t12=-ω02Fm1n1Φm1n1r1,θ1eiω0t1-φm1n1Km1n11-ω¯m1n122+2ξm1n1ω¯m1n12 (9)

After finding the acceleration from Eq. (9), assuming that the mass of the point ism0, then we can express the force as:

fbr1,θ1,t1=-m0ω02Fm1n1Φm1n1r1,θ1eiω0t1-φm1n1Km1n11-ω¯m1n122+2ξm1n1ω¯m1n12 (10)

3.1.2. Vibration analysis of the connecting block

The deflection of a connecting block under free bending vibration can be expressed as a characteristic orthogonal polynomial in the × and y directions [64], [65], expressed as:

Wx,y=m2n2Am2n2Φm2xΨn2ym2,n2=1,2,3,, (11)

where x and y are dimensionless coordinates,x=x2/a2,y=y2/b2, x2 and y2 are the coordinates of the sides of the connecting block, Φm2x and Ψn2y are the bending deflection of the connection block in the x and y directions, the length isa2, the width isb2, the thickness ish2, the material density isρ2, the modulus of elasticity is E2 and the Poisson ratio isμ2, as shown in Fig. 6(c).

The characteristic polynomial is solved by using the trial function to solve the first polynomial; then, a set of polynomials for a certain interval is generated using the Gram-Schmidt process [64].

By substituting the deflection function into the kinetic and strain energy expressions and minimizing the Rayleigh quotient with respect to the coefficient A [61], we can express the resulting characteristic equation as [64]:

m2n2Cm2n2i2j2-λbEm2i20,0Fn2j20,0Am2n2=0 (12)
Cm2n2i2j2=Em2i22,2Fn2j20,0+α4Em2i20,0Fn2j22,2+μ2α2Em2i20,2Fn2j22,0+Em2i22,0Fn2j20,2+21-μ2α2Em2i21,1Fn2j21,1 (13)
Em2i2r2,s2=01dr2Φmdxr2ds2Φidxs2dx,Fn2j2r2,s2=01dr2ψndyr2ds2ψjdys2dy (14)

where α=a2b2 is the side ratio;m2,n2,i2,j2=1,2,3,,; λb=ρ2h2ωb2a24D2 is the natural frequency parameter; D2=E2h23121-μ22 is the bending stiffness of the connecting block; r2,s2=0,1,2 is the order of derivation.

The solution of the characteristic equation produces the natural frequency and vibration mode of the connecting block, and the characteristics of the bending vibrations of the connecting block can be analyzed with these parameters.

As shown in Fig. 6(c), an exciting force fc=Fceiω0t2cosθ2 acts at point x0,y0 of the connecting block, where angle θ2 is the angle between the excitation force fc and the steady-state response force fb in the upper phase. The size of this angle is determined by the eccentricity e12 of the connecting block coordinate origin to the circular plate coordinate origin and the forced response of the circular plate vibration displacement. Since the excitation force is provided by the steady-state response of the upper stage force, it is assumed that point x0,y0 on the connecting block corresponds to point r10,θ10 on the circular thin plate, and the expression for the excitation force fc can be rewritten as:

fc=Fceiω0t1-φm1n1cosθ2 (15)

where ω0 is the excitation frequency, the same as in the previous stage, and Fc is the amplitude of the excitation force.

Thus, the steady-state response of forced vibrations can be derived and expressed as:

w3x,y,t1=m2=0n2=0FcWm2n2x0,y0Wm2n2x,yeiω0t1-φm1n1-φm2n2cosθ2Mm2n2ωm2n221-ω¯m2n222+2ξm2n2ω¯m2n22 (16)

where Wm2n2x,y is a mode function of the connecting block; Mm2n2 is the modal quality; ξm2n2 is the relative damping factor; ω¯m2n2=ω0ωm2n2 is the ratio of the excitation frequency to the natural frequency of the system vibration; φm2n2=tan-12ξm2n2ω¯m2n21-ω¯m2n22 is the system vibration phase.

Whenω0=ωm2n2, the connecting block is in resonance, and the displacement deflection forcing response is dominated by the m2n2 mode. Therefore, the displacement deflection forcing response is expressed as:

w3x,y,t1=FcWm2n2x0,y0Wm2n2x,yeiω0t1-φm1n1-φm2n2cosθ2Mm2n2ωm2n221-ω¯m2n222+2ξm2n2ω¯m2n22 (17)

After finding the forced response of the displacement deflection at resonance, we obtain the second order partial derivative for time t1 using the displacement deflection forcing response functionw3x,y,t1. The acceleration of the connecting block at any point under the Bm2n2 vibration mode can be obtained:

2w3x,y,t1t22=-ω02FcWm2n2x0,y0Wm2n2x,yeiω0t1-φm1n1-φm2n2cosθ2Mm2n2ωm2n221-ω¯m2n222+2ξm2n2ω¯m2n22 (18)

After finding the acceleration from Eq. (18), assuming the mass of the point ism1, we can express the force on the point as:

fdx,y,t1=-ω02m1FcWm2n2x0,y0Wm2n2x,yeiω0t1-φm1n1-φm2n2cosθ2Mm2n2ωm2n221-ω¯m2n222+2ξm2n2ω¯m2n22 (19)

3.1.3. Vibration analysis of the liquid carrier

For the liquid carrier, the model is a cylindrical shell of a finite length. Shell vibration is complex, with displacements in all three directions at the same time, and there is no universally accepted, unified theory for shell vibration [60]. To study the micro-amplitude elliptical motion of particles on the inner surface of the liquid carrier, only two mutually perpendicular vibrations at the same frequency with different phases are considered, the bending vibration and longitudinal vibration of the shell. The surface motion of the shell is ignored, so the cylindrical shell model is simplified to a beam.

In Fig. 6(d), the total length of the liquid carrier isl3, the outer diameter isD3, the material density isρ3, the modulus of elasticity is E3 and the Poisson ratio isμ3. According to the force analysis in Fig. 6(d), the steady-state response of the longitudinal vibration of a liquid carrier with free boundary conditions at both ends needs to be solved.

First, we assume that fe=Feeiω0t3cosθ3 is the longitudinal excitation force at this stage and that the liquid carrier contact point x30,y30 corresponds to point x0,y0 on the connecting block. Then, the longitudinal excitation force fe can be rewritten as:

fe=Feeiω0t1-φm1n1-φm2n2cosθ3 (20)

where φm1n1+φm2n2=φ0.

It is possible to obtain:

fe=Feeiω0t1-φ0cosθ3 (21)

where ω0 is the excitation frequency, the same as in the previous stage, and Fe is the amplitude of the excitation force.

The displacement steady-state response to the longitudinal vibration of a liquid carrier can be expressed according to the principle of the superposition of the vibration mode as:

u1x3,t1=n3=1Wn3x3qn3t1=n3=1Fecosθ3eiω0t1-φ0-φn3Wn3x30Wn3x3Kn31-ω¯n32+2ξn3ω¯n32 (22)

where Wn3x3 is a function of the longitudinal vibration mode;φn3=tan-12ξn3ω¯n31-ω¯n32; ωn3 is the natural frequency of the longitudinal vibration; ω¯n3=ω0ωn3 is the ratio of the excitation frequency to the natural frequency of the longitudinal vibration of the system; ξn3 is the relative damping factor of the system; Kn3=ωn320l3ρ3S3Wn32x3dx3 is the modal stiffness of the system; S3 is the cross-sectional area of the beam corresponding to the outer diameter of the liquid carrier.

Whenωn3=ω0, the longitudinal vibration of the liquid carrier is resonant in ordern3, and the displacement steady-state response is dominated by the vibration mode of ordern3. Therefore, the displacement steady-state response can be simplified as:

u1x3,t1=Wn3x3qn3t1=Fecosθ3eiω0t1-φ0-φn3Wn3x30Wn3x3Kn31-ω¯n32+2ξn3ω¯n32 (23)

Similarly, the steady-state response of the liquid carrier under the action of a transversely concentrated excitation force can be solved:

u2x3,t1=n4=1Wn4x3qn4t1=n4=1Feeiω0t1-φ0-φn4sinθ3Wn4x30Wn4x3ω¯n421-ω¯n422+2ξn4ω¯n42 (24)

where Wn4x3 is a function of the bending vibration mode;φn4=tan-12ξn4ω¯n41-ω¯n42; ω¯n4=ω0ωn4 is the ratio of the excitation frequency to the natural frequency of the bending vibration of the system.

Whenωn4=ω0, the bending vibration of the liquid carrier is resonant in ordern4, and the displacement steady-state response is dominated by order n4 vibration mode. Therefore, the displacement steady-state response can be simplified as:

u2x3,t1=Wn4x3qn4t1=Feeiω0t1-φ0-φn4sinθ3Wn4x30Wn4x3ω¯n421-ω¯n422+2ξn4ω¯n42 (25)

When studying the actual vibration at a fixed position, we can rewrite equations (23), (25) as:

u1(t1)=a3eiω0t1-φ0-φn3u2(t1)=b3eiω0t1-φ0-φn4 (26)

where both a3 and b3 are constants, anda3b3,

a3=Fecosθ3Wn3x30Wn3x3Kn31-ω¯n32+2ξn3ω¯n32b3=Fesinθ3Wn4x30Wn4x3ω¯n421-ω¯n422+2ξn4ω¯n42 (27)

From Eq. (23) and Eq. (25), the phases of the longitudinal vibration and bending vibration are φn3=tan-12ξn3ω¯n31-ω¯n32 andφn4=tan-12ξn4ω¯n41-ω¯n42, respectively. For the liquid carrier, the damping of the longitudinal vibration and bending vibration is not the same, i.e.,ξn3ξn4; bringing in the phase equation givesφn3φn4. Thus, there is a phase difference between the longitudinal vibration and bending vibration with a phase difference ofφn3-φn4. Two mutual perpendicular vibrations at the same excitation frequency with different phases meet the three conditions of micro-amplitude elliptical motion. Therefore, the particles on the tube wall undergo micro-amplitude elliptical motion, which causes the liquid in the tube to move forward. And Eq. (26) is the parametric equation of the micro-amplitude elliptical motion trajectory.

As shown in Fig. 7, when there is a phase difference between longitudinal vibration and bending vibration, the trajectory of a point on the liquid carrier wall in one cycle is elliptical. The bending and longitudinal vibrations at a point on the tube wall during one cycle are shown in Fig. 7(a), where the red line indicates the longitudinal vibration and the green line the bending vibration. The points at different moments in the motion of the elliptical trajectory are shown in Fig. 7(b). The different postures of the liquid carrier at different moments during the cycle are shown in Fig. 7(c)-Fig. 7(f).

Fig. 7.

Fig. 7

Micro-amplitude elliptical motion of a point on the liquid carrier: (a) Longitudinal vibration and bending vibration of a point on the liquid carrier in a single cycle; (b) Trajectory of the micro-amplitude elliptical motion of a point on the liquid carrier; (c) The motion posture of a point on the liquid carrier at the moment A(A’); (d) The motion posture of a point on the liquid carrier at the moment B(B’); (e) The motion posture of a point on the liquid carrier at the moment E(E’); (f) The motion posture of a point on the liquid carrier at the moment F(F’).

When all the microscopic particles on the liquid carrier carry out the micro-amplitude elliptical motion as in Fig. 7, the macroscopic manifestation is that the liquid moves forward because of the frictional force from the tube wall.

3.2. Theory of liquid cavitation

The above analysis shows that the superimposition of longitudinal vibration and bending vibration in the liquid carrier causes the wall of the liquid carrier to form a micro-amplitude elliptical motion, which drives the liquid to move. The longitudinal vibration and bending vibration are analyzed separately to allow a clear analysis of liquid cavitation.

Cavitation theory suggests that a threshold value of sound intensity is required to produce cavitation [66], [67], and the formula for calculating the cavitation threshold can be expressed as follows:

PB=P0-PV+2332σR03P0-PV+2σR0 (28)

where P0 is the static pressure in the liquid; PV is the vapor pressure inside the bubble; σ is the surface tension coefficient; and R0 is the radius of the cavitation nucleus (radius of the bubble).

The above equation is complex, and an empirical formula can be used instead of the formula for the cavitation threshold:

PB=0.8lgη+5 (29)

where η is viscosity of the liquid.

As seen from Eq. (29), the cavitation threshold is higher for high-viscosity liquids. This is because the viscous liquid layer inhibits cavitation events more significantly at higher liquid viscosities. However, as energy continues to be supplied, eventually the viscosity liquid layer is unable to suppress cavitation, and the powerful impact created by the collapse of the cavitation nucleus releases a large amount of energy in a very short time, prompting the liquid on the surface of the atomized end to overcome surface tension and form droplets that escape into the air.

From the above vibration analysis, the acceleration can be found by taking the second derivative of the displacement steady-state response with respect to time. Supposing that the mass of a point ism2, its acceleration in the longitudinal vibration displacement steady-state response can be denoted:

2u1x3,t1t12=-ω02Fecosθ3eiω0t1-φ0-φn3Wn3x30Wn3x3Kn31-ω¯n32+2ξn3ω¯n32 (30)

Then, the force at this point under the steady-state response of the longitudinal vibration displacement can be expressed as follows:

fu1=-ω02m2Fecosθ3eiω0t1-φ0-φn3Wn3x30Wn3x3Kn31-ω¯n32+2ξn3ω¯n32 (31)

Its acceleration in the bending vibration displacement steady-state response can be expressed as follows:

2u2x3,t1t12=-ω02Fesinθ3eiω0t1-φ0-φn4Wn4x30Wn4x3ω¯n421-ω¯n42+2ξn4ω¯n42 (32)

Then, the force at this point in the bending vibration displacement steady-state response can be expressed as follows:

fu2=-ω02m2Fesinθ3eiω0t1-φ0-φn4Wn4x30Wn4x3ω¯n421-ω¯n42+2ξn4ω¯n42 (33)

Eq. (31) and Eq. (33) are the forces at any point of the liquid carrier. Knowing the force on the wall of the tube, the force on the liquid inside the liquid carrier can be analyzed, and when the force on the liquid reaches the cavitation threshold, the liquid produces cavitation, and atomization is achieved.

4. Results and discussion

4.1. Analysis of impedance

The frequency range for the impedance analysis was 300–800 kHz. Impedance measurements were performed on the FTICA under six conditions, no load and loaded liquid viscosities of 50 cP, 75 cP, 100 cP, 125 cP and 150 cP. The results are shown in Fig. 8(a) - Fig. 8(f).

Fig. 8.

Fig. 8

Impedance measurements for liquids with different viscosities: (a) No load; (b) 50 cP; (c) 75 cP; (d) 100 cP; (e) 125 cP; (f) 150 cP.

The minimum impedance value at no load occurs at 694 kHz, as shown in Fig. 8(a). The impedance minimum occurs at 696 kHz when the liquid passes through. The difference between the two cases is 2 kHz. As the fluid viscosity changes, the minimum impedance value remains the same, which indicates that the resonant frequency of the FTICA does not change with the viscosity of the liquid. Therefore, the data presented in Fig. 8(b) - Fig. 8(f) basically overlap. In this study, eight resonant frequency points were selected as possible target frequencies for atomization based on the results of impedance analysis; these frequencies were 326 kHz, 392 kHz, 420 kHz, 507 kHz, 567 kHz, 606 kHz, 648 kHz, 696 kHz and 714 kHz.

4.2. Atomization rate and atomized particle sizes

Note: The center of the connecting block is eccentric to the center of the metal substrate; the viscosity of the atomizing liquid is 50 cP; the atomizer is driven at 85 V.

Atomization experiments were performed with a fluid with a viscosity of 50 cP for the eight resonant frequencies selected from the impedance analysis results. The atomization results are shown in Table 3.

Table 3.

Atomization at different resonance frequencies.

Resonant Frequency Atomization Atomization flow rate (mg/min)
326 kHz No 0
392 kHz No 0
420 kHz No 0
507 kHz Yes 56.35
567 kHz No 0
606 kHz No 0
648 kHz Yes 16.22
696 kHz No 0
714 kHz No 0

The best atomization effect is obtained at 507 kHz. Thus, this frequency was selected as the driving frequency for the subsequent atomization measurement experiments. In the experiments, liquids with six different viscosities were used for atomization. For each viscosity, the driving voltage was increased from 65 V to 85 V, and 11 sets of atomization measurements were taken at 2 V intervals. The experimental results are shown in Fig. 9(a).

Fig. 9.

Fig. 9

Atomization experimental data: (a) Relationship between the atomization rate and driving voltage for liquids with different viscosities at a driving frequency of 507 kHz; (b) Distribution of atomized particle diameter for a liquid with a dynamic viscosity of 1 cP; (c) Distribution of atomized particle diameter for a liquid with a dynamic viscosity of 50 cP; (d) Distribution of atomized particle diameter for a liquid with a dynamic viscosity of 100 cP; (e) Distribution of atomized particle diameter for a liquid with a dynamic viscosity of 150 cP; (f) The atomization effect of a liquid with a dynamic viscosity of 50 cP; (g) The atomization effect of a liquid with a dynamic viscosity of 75 cP; (h) The atomization effect of a liquid with a dynamic viscosity of 100 cP; (i) The atomization effect of a liquid with a dynamic viscosity of 125 cP; (j) The atomization effect of a liquid with a dynamic viscosity of 150 cP; (k) The atomization effect of a liquid with a dynamic viscosity of 175 cP.

It is showed that the proposed FTICA can atomize liquids with viscosities up to 175 cP. When the driving voltage is constant, the atomization rate decreases with increasing viscosity. When the viscosity is constant, the atomization rate increases with increasing driving voltage. To express the atomization effect of this FTICA more visually, selected atomization photos for each viscosity at 85 V drive voltage are shown in Fig. 9(f) - Fig. 9(k).

The atomized particle diameters of the four liquids with viscosities of 1 cP, 50 cP, 100 cP and 150 cP are normally distributed, the mean values of the atomized particles are 9.668 μm, 10.263 μm, 10.683 μm and 10.985 μm, and 50% of the particles are smaller than 9.690 μm, 9.840 μm, 9.907 μm and 10.710 μm, respectively, as shown in Fig. 9(b) - Fig. 9(e). There is a small increase in the average particle size with increasing viscosity, but the increase in diameter is only approximately 10% for a liquid with a viscosity of 150 cP compared to that of distilled water with a viscosity of 1 cP. The experiments show that the FTICA can effectively atomize liquids with viscosities up to 150 cP, with particle sizes of approximately 10 μm under 507 kHz, 85 V driving conditions.

4.3. Vibration displacement measurement of the FTICA

A spectral analysis of the displacement measurements of the vibration source was carried out, where the three resonant frequencies of 507 kHz, 605 kHz and 718 kHz are identified, and the displacement distribution corresponding to these frequencies at the time of maximum displacement is shown in Fig. 10(a) - Fig. 10(c). The results show that in the atomization experiment, the FTICA can achieve atomization when the driving frequency is 507 kHz, but the FTICA cannot achieve atomization when the driving frequency is 605 kHz or 718 kHz. Therefore, when the connecting block is at the maximum vibration displacement position, the vibration can be better transmitted, and atomization occurs in the liquid carrier, as shown in Fig. 10(a). If the connecting block is in a position where there is no vibration or the amplitude is small, as shown in Fig. 10(b) and Fig. 10(c), then the connecting block does not transmit vibration, and subsequent atomization in the liquid carrier is not possible. Therefore, it is necessary to design the structure so that the connecting block is located at the maximum displacement position of the vibration source to achieve atomization.

Fig. 10.

Fig. 10

Vibration experimental data: (a) Displacement distribution of the vibration source at the moment of maximum displacement at 507 kHz resonance frequency; (b) Displacement distribution of the vibration source at the moment of maximum displacement at 605 kHz resonance frequency; (c) Displacement distribution of the vibration source at the moment of maximum displacement at 718 kHz resonance frequency; (d) Displacement distribution of the connecting block at the moment of maximum displacement; (d’) Displacement distribution of the connecting block at the moment T/4; (d’’) Displacement distribution of the connecting block at the moment 3 T/4; (e) Displacement distribution of the liquid carrier at the moment of maximum displacement; (e’) At the moment of T/4, distribution of bending vibration displacement of the liquid carrier synthesized from 101 measurements; (e’’) At the moment of 3 T/4, distribution of bending vibration displacement of the liquid carrier synthesized from 101 measurements; (f) Schematic diagram of the longitudinal vibration displacement of the liquid carrier; (g) Longitudinal vibration displacement of the end face of the inlet end of the liquid carrier; (h) Longitudinal vibration displacement of the end face of the atomization end of the liquid carrier; (i) Distribution of liquid carrier bending vibration displacement measurement points; (j) Vibration displacement of point Γ5; (k) Vibration displacement of point Γ11; (l) Vibration displacement of point Γ18; (m) Vibration displacement of point Γ46; (n) Vibration displacement of point Γ59; (o) Vibration displacement of point Γ100.

As the vibrations transmitted from the vibration source to the connecting block at 606 kHz and 718 kHz are too small to form resonance, the connecting block is analyzed in terms of vibrational displacements only at 507 kHz, and the distribution of displacements at the time of maximum displacement is shown in Fig. 10(d). The Figure represents the displacement distribution at the time of maximum displacement in the forward and backward directions within one cycle, where Fig. 10(d’) shows the moment of maximum displacement in the forward direction and Fig. 10(d’’) shows the moment of maximum displacement in the backward direction. For a clearer representation, the front and side views are shown in both Figures. When the connecting block is mounted eccentrically on a vibration source, the connecting block is subjected to a tilting force that drives it to vibrate out-of-plane, thus, when a single signal is input, it causes longitudinal and bending vibrations of the liquid carrier.

Due to the limitations of the measurement tool, only the displacements at the inlet and outlet ends of the liquid carrier in the direction of the axis were measured in this study to demonstrate the presence of longitudinal displacements. As shown in Fig. 10(g) - Fig. 10(h), the peak displacement at the inlet end is 0.117 μm, and the peak displacement at the atomization end is 0.094 μm.

Fig. 10(e) - Fig. 10(f) shows the vibration displacement of the liquid carrier. Fig. 10(e) shows the distribution of the bending vibration displacement of the liquid carrier synthesized from 101 measurements, which shows that the liquid carrier bending vibration mode is the 30th order vibration at 507 kHz excitation. Fig. 10(f) shows a schematic diagram of the longitudinal vibration displacement of the liquid carrier obtained on the basis of the above experiments, where the orange part indicates the shape of the liquid carrier without vibration and the red part and blue part indicate the tensile shape and compressive shape of the longitudinal vibration of the liquid carrier.

In the bending vibration experiment, a precision displacement stage was used to adjust the vibration measurement position in steps of 0.5 mm. The vibration displacements at a 507 kHz driving frequency were measured uniformly in the direction of the liquid carrier axis at 101 points, denoted by Γ1, Γ2, Γ3, ……, Γ101, as shown in Fig. 10(i). Fig. 10(j) - Fig. 10(o) show the experimental data at points Γ5, Γ11, Γ18, Γ46, Γ59 and Γ100. The maximum displacement of the liquid carrier is approximately 0.27 μm, and the minimum displacement is approximately 0.018 μm, which can be considered to be near the node. The fact that the peak displacement of the liquid carrier bending vibration is higher than that of the liquid carrier longitudinal vibration further demonstrates that longitudinal vibration is more difficult to excite than bending vibration.

The above experiment proved that the vibration of the vibration source is transmitted to the liquid carrier by the connecting block, which causes longitudinal vibration and bending vibration in the liquid carrier. The synthesis of the vibrations in both directions causes the particles on the inside of the liquid carrier to move elliptically, thus prompting the liquid inside the liquid carrier to move toward the atomization end under micro-amplitude elliptical motion conditions. Meanwhile, due to the longitudinal vibration and bending vibration constantly pulling and pressing the liquid, liquid cavitation occurs due to the dissolved fraction of air. When the liquid reaches the atomization end, due to the instantaneous explosive force of cavitation breaking the continuity of the liquid, the liquid at the end escapes into the air at high speed as tiny particle droplets, thus achieving atomization. This is also consistent with the theoretical derivation of the micro-amplitude elliptical motion, and the actual elliptical motion trajectory can be finally obtained according to the experimental measured data.

4.4. Spectral analysis of atomized liquids

The phenomenon of cavitation is an important mechanism for achieving atomization with the proposed FTICA. Therefore, this section presents our investigation of the changes that occur in the atomized liquid inside the liquid carrier by Raman spectroscopy and absorbance experiments with full wavelength light.

First, Raman spectroscopy was used to verify whether the molecular structure of the liquid changes from before to after atomization. Propylene glycol liquid with a viscosity of 50 cP was used for the experiments. The original propylene glycol liquid before atomization and liquid obtained by collecting droplets after atomization were placed on slides. The results of Raman spectroscopy analysis of both are shown in Fig. 11(a).

Fig. 11.

Fig. 11

Spectroscopic experimental data: (a) Raman spectra of the liquid before and after atomization; (b) Light intensity before atomization; (c) Absorbance before atomization; (d) Absorbance after atomization; (e) Light intensity after atomization.

The spectral peaks at different positions in the diagram represent different functional groups, and the intensities of the peaks represent the concentrations of functional groups. The Raman spectral peaks of the liquids before and after atomization were identical, indicating that the two were the same substance and that the FTICA achieved atomization through a physical mechanism. In addition, the spectral intensity of the liquid before atomization is slightly higher than that after atomization, as shown by the black and red curves in Fig. 11(a), respectively, indicating that the concentration of functional groups in the liquid before atomization is higher than the concentration of functional groups after atomization, which is the result of a small number of droplets drifting into the air when the droplets are collected after atomization. This experiment shows that the degree of cavitation of the liquid after vibration, although intense, does not reach the molecular level, and therefore, no new substances are produced by the atomization. The FTICA can achieve atomization in the physical sense and meets the basic requirements of an ultrasonic atomizer.

In the second experiment, a high-power light source transmitter and receiver was used to analyze the absorbance and light intensity of the liquid before and after atomization. The experiment was carried out using propylene glycol liquid with a viscosity of 50 cP.

We assume that the light intensities at the receiving end of the light source before and after atomization are Ib and Ia, respectively, and define the absorbance coefficient after atomization as:

Aa=lgIbIa (34)

Due to the constant light intensity at the receiving end before atomization, the absorbance before atomization should beAb=lgIbIb=0. The experimental results are shown in Fig. 11(b) - Fig. 11(e). Fig. 11(b) shows the light intensity Ib distribution at the receiving end after passing through the liquid before the FTICA is turned on. Fig. 11(c) shows the absorbance before atomization Ab, the fluctuations of which demonstrate the systematic errors introduced into the instrument by environmental factors. The absorbance after atomization Aa is shown in Fig. 11(d). The Raman spectroscopy experiments show that the atomization does not produce new material, so the difference in absorbance in Fig. 11(c) and Fig. 11(d) is due to the cavitation of the gas originally dissolved in the liquid caused by the high pressure generated during the vibration of the FTICA. Using Eq. (34) and the light intensity before and absorbance after atomization, Ib and Aa, measured in the experiment, the light intensity after atomization Ia can be calculated, and the distribution is shown in Fig. 11(e). The occurrence of cavitation in the FTICA leads to the creation of a large amount of tiny bubbles. During the creation and collapse of these small bubbles, the liquid is atomized, and more light is absorbed and reflected, so the light intensity at the receiving end is reduced and the absorption in the atomization is increased. This experiment demonstrates the presence of liquid cavitation during the atomization process.

4.5. Comparison with conventional ultrasonic atomizers

To discuss and demonstrate the advantages and disadvantages of the FTICA in this study, we compared it with a variety of conventional ultrasonic atomizers and show in Table 4.

Table 4.

Comparison with conventional ultrasonic atomizers.

Type Advantage Disadvantage Maximum atomizing viscosity
SAW atomizer Large atomizing volume. Simple structure. Energy utilization rate is low. The droplet size can- not be controlled. The particle size distribution of the droplets is not concentrated. About 30 cP
Static mesh atomizer Atomization process is controllable. The droplets are evenly distributed. Complex structure
Dynamic mesh atomizer Simple structure. High energy utilization. Low viscosity of atomized liquid
FTICA High viscosity of atomized liquid. Simple structure. The droplet size can be controlled. The droplets are evenly distributed. Low atomizing rate 175 cP

Analyzing Table 4, we can know that compared to the conventional ultrasonic atomizer, the FTICA in this study is able to atomize high-viscosity liquids without parameter optimization and control the size of atomized particle diameter. This is its most obvious advantage.

At present, because the parameters of the FTICA in this study have not been optimized, it has a smaller atomization rate than other ultrasonic atomizers. However, we believe that the deficiency can be overcome in the subsequent optimization experiments.

5. Conclusion

In this study, we propose a novel atomization mechanism that uses two coupled vibrations to induce micro-amplitude elliptical motion of the particles on the surface of the liquid carrier, which produces a similar effect as localized traveling waves to push the liquid forward and induce cavitation to achieve atomization. A prototype was designed and built to atomize liquids with a maximum viscosity of 175 cP at room temperature, with a maximum atomization rate of 56.35 mg/min and an average particle diameter of approximately 10 µm. A vibration model based on a three-part structure with a circular base, a rectangular plate and a needle-shaped through-tube for coupled atomization modes was developed. The vibration displacements of the components of the atomized prototype were measured using a 3D Doppler vibrometer at a frequency of 507 kHz, which showed that the vibration mode of the atomized structure was of order 30 and that the theoretical solution was of order 26, where the error was approximately 15%.

It was postulated that the longitudinal and bending vibrations of the needle-through-tube led to the cavitation effect of the liquid inside it and thus to atomization. Based on cavitation theory, a force-based model of the inner wall of the needle-type tube and its cavitation threshold were developed. A Raman spectroscopy experiment was used to verify that there were no changes in the chemical properties of the liquid before and after atomization, and an absorption spectroscopy experiment was used to demonstrate the occurrence of cavitation, verifying the conjecture that cavitation causes atomization.

This study proposes a new mechanism for high-viscosity physical atomization, offering new possibilities for transpulmonary inhalation therapy, engine fuel supply, solid-state battery processing and other areas requiring high-viscosity microparticles. In subsequent studies, the current structural parameters will be further optimized, and the atomization performance at driving frequencies above 800 kHz will be further investigated.

CRediT authorship contribution statement

Tang Xie: Methodology, Formal analysis, Writing – original draft. Yaohua Zeng: Methodology, Investigation, Writing – original draft. Zhenzhen Gui: Writing – review & editing. Mingdong Ma: Investigation. Yuxuan Huo: Investigation. Weirong Zhang: Validation. Tian Tan: Investigation. Tao Zou: Conceptualization, Methodology. Fan Zhang: Formal analysis, Writing – review & editing. Jianhui Zhang: Conceptualization, Methodology, Supervision.

Declaration of Competing Interest

The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.

Acknowledgements

This work was supported by National Natural Science Foundation of China (Grant No. 51705093), Guangdong Basic and Applied Basic Research Foundation (Grant No. 2019B1515120017, 2022A1515010265 and 2020A1515110619), Science and Technology Program of Guangzhou (Grant No. 202201020158 and 202201020191), The Graduate-Ability-Promotion Plan of Guangzhou University (Granted No. 2022GDJC-M21). And we thank Sunny Optical Intelligence Technology Co.,Ltd. for providing the vibration measurement equipment and for helping with the vibration measurement experiments, and Optosky (Xiamen) Photonics Inc. for providing the spectroscopic measurement equipment and help with the spectroscopic measurement experiments. We also thank Professor Jiamei Jin of Nanjing University of Aeronautics and Astronautics for his theoretical guidance.

Footnotes

Appendix A

Supplementary data to this article can be found online at https://doi.org/10.1016/j.ultsonch.2023.106331.

Contributor Information

Tao Zou, Email: tzou@gzhu.edu.cn.

Fan Zhang, Email: zhf_jd@gzhu.edu.cn.

Jianhui Zhang, Email: zhangjh@nuaa.edu.cn.

Appendix A. Supplementary data

The following are the Supplementary data to this article:

Supplementary video 1
Download video file (4.1MB, mp4)
Supplementary video 2
Download video file (5.1MB, mp4)
Supplementary video 3
Download video file (6.2MB, mp4)

References

  • 1.Donnelly T.D., Hogan J., Mugler A., Schommer N., Schubmehl M., Bernoff A.J. An experimental study of micron-scale droplet aerosols produced via ultrasonic atomization. Phys. Fluids. 2004;16(8) doi: 10.1063/1.1759271. [DOI] [Google Scholar]
  • 2.Rajan R., Pandit A.B. Correlations to predict droplet size in ultrasonic atomization. Ultrasonics. 2001;39(4):235–255. doi: 10.1016/S0041-624X(01)00054-3. [DOI] [PubMed] [Google Scholar]
  • 3.Zhang J., Yan Q., Sun W. Advances in piezoelectric atomizers. Trans. Nanjing Univ. Aeronaut. Astronaut. 2020;37(1):54–69. doi: 10.16356/j.1005-1120.2020.01.005. [DOI] [Google Scholar]
  • 4.Topp M.N., Eisenklam P. Industrial and medical uses of ultrasonic atomizers. Ultrasonics. 1972;10(3):127–133. doi: 10.1016/0041-624X(72)90009-1. [DOI] [PubMed] [Google Scholar]
  • 5.Lacas F., Versaevel P., Scouflaire P., Coeur-Joly G. Design and performance of an ultrasonic atomization system for experimental combustion applications. Part. Part. Syst. Char. 1994;11(2):166–171. doi: 10.1002/ppsc.19940110210. [DOI] [Google Scholar]
  • 6.Newman S.P., Clarke S.W. Therapeutic aerosols 1–physical and practical Considerations. Thorax. 1983;38(12):881. doi: 10.1136/thx.38.12.881. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 7.Okawa H., Nishi K., Kawamura Y., Kato T., Sugawara K. Utilization of ultrasonic atomization for dust control in underground mining. Jpn. J. Appl. Phys. 2017;56(7S1):07JE10. doi: 10.7567/JJAP.56.07JE10. [DOI] [Google Scholar]
  • 8.Ro S., Imai R., Kitamura A., Jinta T., Nishimura N. Ultrasonic humidifier lung as a mimic of COVID-19. Respirol. Case Rep. 2021;9(6):e00761. doi: 10.1002/rcr2.761. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 9.Wood R.W., Loomis A.L. The physical and biological effects of high-frequency sound-waves of great intensity. The London, Edinburgh, and Dublin Philosoph. Mag. J. Sci. 1927;4(22):417–436. doi: 10.1080/14786440908564348. [DOI] [Google Scholar]
  • 10.White R.M., Voltmer F.W. Direct piezoelectric coupling to surface elastic waves. Appl. Phys. Lett. 1965;7(12):314–316. doi: 10.1063/1.1754276. [DOI] [Google Scholar]
  • 11.D. Sun, K. F. Böhringer, M. Sorensen, E. Nilsson, D. R. Goodlett, Droplet Delivery Control for Surface Acoustic Wave Nebulization Mass Spectrometry. In: 2019 20th International Conference on Solid-State Sensors, Actuators and Microsystems & Eurosensors XXXIII (TRANSDUCERS & EUROSENSORS XXXIII), 2019, pp. 49-52. https://doi.org/10.1109/TRANSDUCERS.2019.8808244.
  • 12.Nakamoto T., Ollila S., Kato S., Li H., Qi G. Enhancement Method of Surface Acoustic Wave-Atomizer Efficiency for Olfactory Display. J. Vis. Exp. 2018;141:e58409. doi: 10.3791/58409. [DOI] [PubMed] [Google Scholar]
  • 13.B. De Heij, B. van der Schoot, N. F. de Rooij, H. Bo, J. Hess, Modelling and Optimisation of a vaporiser for inhalation drug therapy. In: Proceedings of the Second International Conference on Modelling and Simulation of Microsystems, 1999, pp. 542-545.
  • 14.Wang G.H., Zhou Z.Y., Yuan S.M., Liu C.G. Theoretical and experimental analysis of droplet characteristics in piezoelectrically actuated microjet. J. Chin. Sci. Instrum. 2002;23:6–8. doi: 10.19650/j.cnki.cjsi.2002.s3.003. [DOI] [Google Scholar]
  • 15.Jeng Y.R., Su C.C., Feng G.H., Peng Y.Y. An investigation into a piezoelectrically actuated nebulizer with μEDM-made micronozzlearra. Exp. Therm Fluid Sci. 2007;31(8):1147–1156. doi: 10.1016/j.expthermflusci.2006.12.001. [DOI] [Google Scholar]
  • 16.Maehara N., Ueha S., Mori E. Influence of the vibrating system of a multipinhole-plate ultrasonic nebulizer on its performance. Rev. Sci. Instrum. 1986;57(11):2870–2876. doi: 10.1063/1.1139006. [DOI] [Google Scholar]
  • 17.Yan Q., Wu C., Zhang J. Effect of the dynamic cone angle on the atomization performance of a piezoceramic vibrating mesh atomizer. Appl. Sci. 2019;9(9):1836. doi: 10.3390/app9091836. [DOI] [Google Scholar]
  • 18.Shafaee M., Mahmoudzadeh S. Numerical investigation of spray characteristics of an air-blast atomizer with dynamic mesh. Aerosp. Sci. Technol. 2017;70:351–358. doi: 10.1016/j.ast.2017.08.024. [DOI] [Google Scholar]
  • 19.Lang R.J. Ultrasonic atomization of liquids. J. Acoust. Soc. Am. 1962;34(1):6–8. doi: 10.1121/1.1909020. [DOI] [Google Scholar]
  • 20.Perron R.R. The design and application of a reliable ultrasonic atomizer. IEEE Trans. Sonics Ultrason. 1967;14(4):149–152. doi: 10.1109/T-SU.1967.29430. [DOI] [Google Scholar]
  • 21.Kim J., Kim J.J., Lee S.J. Efficient removal of indoor particulate matter using water microdroplets generated by a MHz-frequency ultrasonic atomizer. Build. Environ. 2020;175 doi: 10.1016/j.buildenv.2020.106797. [DOI] [Google Scholar]
  • 22.Percin G., Khuri-Yakub B.T. Piezoelectrically actuated flextensional micromachined ultrasound transducers. II. Fabrication and experiments. IEEE Trans. Ultrason. Ferroelectr. Freq. Control. 2002;49(5):585–595. doi: 10.1109/TUFFC.2002.1002457. [DOI] [PubMed] [Google Scholar]
  • 23.Tseng H.Y., Lin H.L., Chiang H.S. In vitro evaluation of aerosol delivery by hand-held mesh nebulizers in an adult spontaneous breathing lung model. J. Aerosol Med. Pulm. Drug Deliv. 2022;35(2):83–90. doi: 10.1089/jamp.2021.0010. [DOI] [PubMed] [Google Scholar]
  • 24.Wu S., Huang J., Zhang Z., Wu J., Zhang J., Chen W. Safety, tolerability, and immunogenicity of an aerosolised adenovirus type-5 vector-based COVID-19 vaccine (Ad5-nCoV) in adults: preliminary report of an open-label and randomised phase 1 clinical trial. Lancet Infect. Dis. 2021;21(12):1654–1664. doi: 10.1016/S1473-3099(21)00396-0. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 25.Eliseeva S.N., Shkreba E.V., Kamenskii M.A., Tolstopjatova E.G., Holze R., Kondratiev V.V. Effects of conductive binder on the electrochemical performance of lithium titanate anodes. Solid State Ion. 2019;333:18–29. doi: 10.1016/j.ssi.2019.01.011. [DOI] [Google Scholar]
  • 26.Cushing A., Zheng T., Higa K., Liu G. Viscosity analysis of battery electrode slurry. Polymers. 2021;13(22):4033. doi: 10.3390/polym13224033. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 27.Kim K.M., Jeon W.S., Chung I.J., Chang S.H. Effect of mixing sequences on the electrode characteristics of lithium-ion rechargeable batteries. J. Power Sources. 1999;83(1–2):108–113. doi: 10.1016/S0378-7753(99)00281-5. [DOI] [Google Scholar]
  • 28.Finlay W.H., Lange C.F., King M., Speert D.P. Lung delivery of aerosolized dextran. Am. J. Respir. Crit. Care Med. 2000;161(1):91–97. doi: 10.1164/ajrccm.161.1.9812094. [DOI] [PubMed] [Google Scholar]
  • 29.Zhang P., Su X., Chen H., Geng L., Zhao X. Assessing fuel properties effects of 2, 5-dimethylfuran on microscopic and macroscopic characteristics of oxygenated fuel/diesel blends spray. Sci. Rep. 2020;10(1):1–12. doi: 10.1038/s41598-020-58119-y. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 30.Boggavarapu P., Ravikrishna R.V. A review on atomization and sprays of biofuels for IC engine applications. Internat. J. Spray Combust. Dyn. 2013;5(2):85–121. doi: 10.1260/1756-8277.5.2.85. [DOI] [Google Scholar]
  • 31.P. Boggavarapu, R. V. Ravikrishna, A comparison of jatropha methyl ester and diesel non-evaporating sprays. In: 12th international conference on liquid atomization and spray systems, 2012.
  • 32.Deshmukh D., Mohan A.M., Anand T.N.C., Ravikrishna R.V. Spray characterization of straight vegetable oils at high injection pressures. Fuel. 2012;97:879–883. doi: 10.1016/j.fuel.2012.01.078. [DOI] [Google Scholar]
  • 33.Wu Z.Y., Deng L., Li J.T., Huang Q.S., Lu Y.Q., Liu J., Sun S.G. Multiple hydrogel alginate binders for Si anodes of lithium-ion battery. Electrochim. Acta. 2017;245:371–378. doi: 10.1016/j.electacta.2017.05.094. [DOI] [Google Scholar]
  • 34.Lozano A., Garcia J.A., Navarro J.L., Calvo E., Barreras F. Influence of viscosity on droplet size distribution and generation rate in ultrasonic atomization. Atomization Sprays. 2010;20(11) doi: 10.1615/AtomizSpr.v20.i11.10. [DOI] [Google Scholar]
  • 35.Law J., Kong K.W., Chan H.Y., Sun W., Li W.J., Chau E.B.F., Chan G.K.M. Atomization of High-Viscosity Fluids for Aromatherapy Using Micro-heaters for Heterogeneous Bubble Nucleation. Sci. Rep. 2017;7(1):1–14. doi: 10.1038/srep40289. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 36.Lefebure A., Shim D. Ultrasonic atomization of highly viscous biodegradable oils for MQL applications. J. Mech. Sci. Technol. 2021;35(12):5503–5516. doi: 10.1007/s12206-021-1122-y. [DOI] [Google Scholar]
  • 37.Li C., Lu C.Y., Ma Y.X., Li S.Y., Huang W.Q. Design of an ultrasonic motor with multi-vibrators. J. Zhejiang Univ.-Sci. A. 2016;17(9):724–732. doi: 10.1631/jzus.A1500316. [DOI] [Google Scholar]
  • 38.Liu Y., Shi S., Li C., Chen W., Liu J. A novel standing wave linear piezoelectric actuator using the longitudinal-bending coupling mode. Sens. Actuators, A. 2016;251:119–125. doi: 10.1016/j.sna.2016.10.015. [DOI] [Google Scholar]
  • 39.Ueha S. Ultrasonic motors theory and applications. Oxford Science Publications. 1993;7:1–20. [Google Scholar]
  • 40.Zhao C.S. Recent progress in ultrasonic motor techniques. J. Vib. Measur. Diagn. 2004;24(1):1–5. [Google Scholar]
  • 41.Kang D., Kim K., Kim D., Shim J., Gweon D.G., Jeong J. Optimal design of high precision XY-scanner with nanometer-level resolution and millimeter-level working range. Mechatronics. 2009;19(4):562–570. doi: 10.1016/j.mechatronics.2009.01.002. [DOI] [Google Scholar]
  • 42.Yu H., Liu Y., Tian X., Zhang S., Liu J. A precise rotary positioner driven by piezoelectric bimorphs: Design, analysis and experimental evaluation. Sens. Actuators, A. 2020;313 doi: 10.1016/j.sna.2020.112197. [DOI] [Google Scholar]
  • 43.Peng J., Ma L., Li X., Tang H., Li Y., Chen S. A novel synchronous micro motor for intravascular ultrasound imaging. IEEE Trans. Biomed. Eng. 2018;66(3):802–809. doi: 10.1109/TBME.2018.2856930. [DOI] [PubMed] [Google Scholar]
  • 44.Wang L., Hou Y., Zhao K., Shen H., Wang Z., Zhao C., Lu X. A novel piezoelectric inertial rotary motor for actuating micro underwater vehicles. Sens. Actuators, A. 2019;295:428–438. doi: 10.1016/j.sna.2019.06.014. [DOI] [Google Scholar]
  • 45.Liang W., Ma J., Ng C., Ren Q., Huang S., Tan K.K. Optimal and intelligent motion control scheme for an Ultrasonic-Motor-Driven XY stage. Mechatronics. 2019;59:127–139. doi: 10.1016/j.mechatronics.2019.03.004. [DOI] [Google Scholar]
  • 46.Stekke J., Tendero C., Tierce P., Courtois C., Rauwel G., Lo J., Pigache F. Low-Voltage plasma Jet With piezoelectric generator: preliminary evaluation of decontamination capabilities. IEEE Trans. Plasma Sci. 2020;48(5):1264–1270. doi: 10.1109/TPS.2020.2985406. [DOI] [Google Scholar]
  • 47.T. Sakayachi, Y. Nagira, M. Hikita, Study on achievement of simultaneous X, Y movements and theta rotation using straight-move ultrasonic vibrators. In: 2015 IEEE International Ultrasonics Symposium (IUS), 2015, pp. 1-4. https://doi.org/10.1109/ULTSYM.2015.0539.
  • 48.Sun C.H., Shang G.Q., Tao Y.Y., Li Z.R. A review on application of piezoelectric energy harvesting technology. Adv. Mat. Res. 2012;516:1481–1484. doi: 10.4028/www.scientific.net/AMR.516-517.1481. [DOI] [Google Scholar]
  • 49.Shang G.Q., Tao Y.Y., Li Z.R., Sun C.H. On piezoelectric harvesting technology. Adv. Mat. Res. 2012;516:1496–1499. doi: 10.4028/www.scientific.net/AMR.516-517.1496. [DOI] [Google Scholar]
  • 50.Zhang H.F., Wang B., Zhao A.L. Research on power supply for adaptive ultrasonic vibration cutting based on piezoelectric technology. Agro Food Ind Hi Tech. 2017;28(1):2661–2665. [Google Scholar]
  • 51.M. Renaud, T. Sterken, A. Schmitz, P. A. F. P. Fiorini, C. A. V. H. C. Van Hoof, R. A. P. R. Puers, Piezoelectric harvesters and MEMS technology: fabrication, modeling and measurements. In: TRANSDUCERS 2007-2007 International Solid-State Sensors, Actuators and Microsystems Conference, 2007, pp: 891-894. https://doi.org/10.1109/SENSOR.2007.4300274.
  • 52.Ryndzionek R., Sienkiewicz Ł. A review of recent advances in the single-and multi-degree-of-freedom ultrasonic piezoelectric motors. Ultrasonics. 2021;116 doi: 10.1016/j.ultras.2021.106471. [DOI] [PubMed] [Google Scholar]
  • 53.Tian X., Liu Y., Deng J., Wang L., Chen W. A review on piezoelectric ultrasonic motors for the past decade: Classification, operating principle, performance, and future work perspectives. Sens. Actuators, A. 2020;306 doi: 10.1016/j.sna.2020.111971. [DOI] [Google Scholar]
  • 54.Hagood N.W., McFarland A.J. Modeling of a piezoelectric rotary ultrasonic motor. IEEE Trans. Ultrason. Ferroelectr. Freq. Control. 1995;42(2):210–224. doi: 10.1109/58.365235. [DOI] [Google Scholar]
  • 55.Ting Y., Tsai Y.R., Hou B.K., Lin S.C., Lu C.C. Stator design of a new type of spherical piezoelectric motor. IEEE Trans. Ultrason. Ferroelectr. Freq. Control. 2010;57(10):2334–2342. doi: 10.1109/TUFFC.2010.1694. [DOI] [PubMed] [Google Scholar]
  • 56.Lijima T., Wada M., Nakagawa Y., Itoh H. Ultrasonic motor using flexual standing wave. Japan. J. Appl. Phys. Suppl. 1987;26(S1):191–193. doi: 10.7567/JJAPS.26S1.191. [DOI] [Google Scholar]
  • 57.J. Twiefel, W. Wurpts, J. Wallaschek, Theoretical and experimental treatment of standing wave type motors contact behavior. In: 2009 IEEE International Ultrasonics Symposium, 2009 pp: 1-4. https://doi.org/10.1109/ULTSYM.2009.5442023.
  • 58.Nakamura K., Kurosawa M., Ueha S. Characteristics of a hybrid transducer-type ultrasonic motor. IEEE Trans. Ultrason. Ferroelectr. Freq. Control. 1991;38(3):188–193. doi: 10.1109/58.79602. [DOI] [PubMed] [Google Scholar]
  • 59.Satonobu J.S.J., Torii N.T.N., Nakamura K.N.K., Ueha S.U.S. Construction of megatorque hybrid transducer type ultrasonic motor. Jpn. J. Appl. Phys. 1996;35(9S):5038. doi: 10.1143/JJAP.35.5038. [DOI] [Google Scholar]
  • 60.Zhao C. Springer Science & Business Media; 2011. Ultrasonic motors: technologies and applications. [Google Scholar]
  • 61.Schmitz T.L., Smith K.S. Mechanical vibrations. Model. Measur. 2012 [Google Scholar]
  • 62.Xu Z. Higher Education; Beijing: 2006. Elastic mechanics. [Google Scholar]
  • 63.Soedel W. CRC Press; 2004. Vibrations of shells and plates. [Google Scholar]
  • 64.Bhat R.B. Natural frequencies of rectangular plates using characteristic orthogonal polynomials in Rayleigh-Ritz method. J. Sound Vib. 1985;102(4):493–499. doi: 10.1016/S0022-460X(85)80109-7. [DOI] [Google Scholar]
  • 65.Leissa A.W. The free vibration of rectangular plates. J. Sound Vib. 1973;31(3):257–293. doi: 10.1016/S0022-460X(73)80371-2. [DOI] [Google Scholar]
  • 66.Zhang J.Y., Du Y.X., Liu J.Q., Sun Y.R., Yao Z.F., Zhong Q. Experimental and numerical investigations of the collapse of a laser-induced cavitation bubble near a solid wall. J. Hydrodyn. 2022:1–11. doi: 10.1007/s42241-022-0017-4. [DOI] [Google Scholar]
  • 67.Rood E. mechanisms of cavitation inception. J. Fluids Eng. 1991;113(2):163–175. doi: 10.1115/1.2909476. [DOI] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

Supplementary video 1
Download video file (4.1MB, mp4)
Supplementary video 2
Download video file (5.1MB, mp4)
Supplementary video 3
Download video file (6.2MB, mp4)

Articles from Ultrasonics Sonochemistry are provided here courtesy of Elsevier

RESOURCES