Skip to main content
Springer logoLink to Springer
. 2022 Aug 8;29(42):64252–64258. doi: 10.1007/s11356-022-22435-9

Magic extraction: solid-phase extraction and analytical pyrolysis to study polycyclic aromatic hydrocarbon and polychlorinated biphenyls in freshwater

Jacopo La Nasa 1,2,, Greta Biale 1, Francesca Modugno 1, Alessio Ceccarini 1, Stefania Giannarelli 1
PMCID: PMC9477944  PMID: 35939195

Abstract

Polycyclic aromatic hydrocarbons and polychlorinated biphenyls are commonly categorized as persistent organic pollutants. In order to analyze these pollutants, customized stationary phases are increasingly being developed and synthesized for solid-phase extraction. In this work, we tested a new solventless solid-phase extraction approach based on the use of a Magic Chemisorber® (Frontier Lab) which consists of a bead-covered polydimethylsiloxane stationary phase with a thickness of 500 µm. These devices are directly immersed into aqueous samples and then introduced into a pyrolysis–gas chromatography-mass spectrometry system equipped with a cryofocusing system for the thermal desorption and analysis of the adsorbed species. Our new method performs better than the most recent solid-phase extraction devices, with limits of detection lower than 2.7 ng/L and limits of quantification lower than 9.0 ng/L. The method was tested on standard compounds and on an environmental sample, showing the potential to characterize other chemical species besides the persistent organic pollutants, such as phthalate plasticizers and antioxidants.

Supplementary Information

The online version contains supplementary material available at 10.1007/s11356-022-22435-9.

Keywords: PCBs, PAHs, Pyrolysis, Gas chromatography, Mass spectrometry, Thermal desorption

Introduction

Polycyclic aromatic hydrocarbons (PAHs) and polychlorinated biphenyls (PCBs) are classes of compounds that are commonly categorized as persistent organic pollutants (POPs) (Fitzgerald and Wikoff 2014, Huo et al. 2017; Wu et al. 2021). These compounds are present in most environmental compartments especially water, soil, and air (Huang et al. 2020, Manoli and Samara 1999, Qu et al. 2019, Vane et al. 2014). PAHs and PCBs are hydrophobic, environmentally stable chemicals that tend to bioaccumulate, with toxic effects on animal and human health (Drábová et al. 2022; Nakata et al. 2003; Vasseghian et al. 2021).

Because of their low water solubility, PAHs and PCBs are present in water basins at trace and ultra-trace levels (Wolska et al. 1999), which makes their determination challenging. Robust analytical methods have thus been developed to accurately isolate, enrich, and detect them in environmental aqueous matrices (Mwanza et al. 2021; Wolska et al. 1999; Wu et al. 2021).

In fact, analytical techniques suitable for PAH and PCB quantification at very low concentrations are fundamental according to current legislation protocols (Pellicer-Castell et al. 2022; Vasseghian et al. 2021).

Solid-phase extraction (SPE) is commonly used to enrich PCBs and PAHs before analysis because it requires low amount of solvents and allows good sample enrichment (Simsek et al. 2021). Other similar methods have been applied for the same purpose, such as solid-phase microextraction (SPME) (Baktash and Bagheri, 2017, Domínguez et al. 2018; Omarova et al. 2022) and stir bar sorptive extraction (SBSE) (Tankiewicz et al. 2011; Xiao et al. 2016). In addition, several sorbent materials (Nouri et al. 2020) with increasing selectivity and performing properties have been used such as hypercrosslinked polymers (Li et al. 2021), gold nanoparticles (Gutiérrez-Serpa et al. 2017; Pellicer-Castell et al. 2022), graphene oxide composites (Peng et al. 2022; Sheng et al. 2021; Song et al. 2022), and aerogels (Sun et al. 2022).

In this work, we propose a new analytical method for the preconcentration and quantitation of PCBs and PAHs in water samples based on SPE and thermal desorption in a pyrolysis–gas chromatography-mass spectrometry (Py-GC–MS) system. The SPE devices used are Magic Chemisorbers® (Frontier Lab) which consist of a polydimethylsiloxane (PDMS) stationary phase chemically bonded to a deactivated titanium tube. With chemisorbers, sample preparation is rapid, low-cost, efficient, environmentally friendly, and relatively easy. Our method was first validated using reference materials and subsequently tested on a water sample from the Morto Nuovo River (Pisa, Tuscany). To the best of our knowledge, this is the first application of Chemisorbers for the analysis of PAHs and PCBs in water matrix samples.

Materials and methods

Chemicals

Native PAH Stock Solution L429-PAR (purity > 98%, Wellington Laboratories, Canada): naphthalene, 2-methylnaphthalene, acenaphthylene, acenaphthene, fluorene, phenanthrene, anthracene, fluoranthene, pyrene, benz[a]anthracene, chrysene, benzo[b]fluoranthene, benzo[k]fluoranthene, benzo[e]pyrene, benzo[a]pyrene, perylene, indeno[1,2,3-c,d]pyrene, dibenz[a,h]anthracene, benzo[g,h,i]perylene.

Polychlorinated biphenyls’ list (purity > 98%, Labor. Dr. Ehrenstorfer, Russia): 4,4′-dichlorobiphenyl (PCB 15), 2,4′,5-trichlorobiphenyl (PCB 31), 2,4,2′,4′,5′-pentachlorobiphenyl (PCB99), 2,3,3′,4′,6-pentachlorobiphenyl (PCB110), 2,3,3′,5′,6-pentachlorobiphenyl (PCB 113), 2,2′,3,3′,4,6′-hexachlorobiphenyl (PCB132), 2,3,3′,4,4′,6-hexachlorobiphenyl (PCB 158); (from Cambridge Isotope Laboratories 35 µg/mL in isooctane): 2,2′,3,4,6′-pentachlorobiphenyl (PCB89), 2,2′,3,4′,5′,6-hexachlorobiphenyl (PCB149), 2,2′,3,5,5′,6-hexachlorobiphenyl (PCB151), 2,3,3′,4,4′,5-hexachlorobiphenyl (PCB156).

As an internal standard for PHA extraction and analysis, the L429-IS deuterated standard mix (purity > 98%, Wellington Laboratories) was used, while for the PCBs the mass-labeled MBP-MXE mix (purity > 99%, Wellington Laboratories) was used. The complete lists of the chemical species used as internal standards are reported in the Supporting Information.

2,2,4-Trimethylpentane (isooctane), pesticide grade, Fluka; Water LC–MS grade (Merck, Germany).

Standard solutions

Standard and internal standard solutions were obtained by diluting the certified ones with LC–MS grade water. All the solutions were stored in a refrigerator at 4 °C. All reagents and chemicals were used without any further purification.

Environmental sample pretreatment

The river “Morto Nuovo” borders the municipalities of San Giuliano Terme and Pisa, and its mouth is located within a national park that is recognized by UNESCO as an environmental biosphere reserve. Its hydraulic role, on the other hand, is due to the confluence of the channel of the wastewater and the water from the run-off of the cultivated fields in the northern part of the Pisan plain. Numerous untreated civil drainage channels enter its course which negatively impact on the river, making it of interest for environmental monitoring. The river is largely artificial, fed by drainage channels; therefore, it does not have a real source. Its flow gradually increases as it crosses the plain between two major rivers: the Serchio and the Arno (Figure S.1 in the Supporting Information).

The water sample was collected by lowering a stainless-steel metal container into the center of the water course, to avoid contamination from the banks. The sample was then filtered and stored in 1-L stainless steel containers for the analysis of organic compounds, which were then placed in a refrigerator at 4 °C, without any further purification. A field blank using LC–MS grade water was prepared and analyzed following the same procedure used on the water sample from the river.

Extraction procedure

The extraction of PAHs and PCBs was performed using a Magic Chemisorber® with a polydimethylsiloxane (PDMS) stationary phase. The Chemisorber is a solid-phase extraction device in which a film of 500 µm of PDMS is chemically bonded to the outer surface of a deactivated titanium tube (length 6 mm). For this preliminary study, all the solutions were subjected to extractions with the Chemisorber under stirring at 25 °C (Fig. 1) in a sealed vial at increasing extraction times (from 30 min to 8 h). Optimal conditions were obtained after 1 h of extraction time. The volume of the solutions/samples used for this study is 50 mL.

Fig. 1.

Fig. 1

Chemisorber solid-phase extractor

Pyrolysis–gas chromatography-mass spectrometry equipment and conditions

The analyses were performed using a multi-shot pyrolyzer EGA/PY-3030D (Frontier Laboratories, Japan) coupled with an 8890 gas chromatograph, combined with a 5977B mass selective single quadrupole mass spectrometer detector (Agilent Technologies, US). The pyrolyzer system was equipped with a quick stabilizer pressure control QSP-1046E (Frontier Lab), and a Micro jet Cryo-Trap MJT-1035E (Frontier Lab). The cryo-focusing time was automatically controlled by the instrument software.

The Chemisorbers were desorbed in the pyrolysis system at 280 °C. The desorbed compounds were cryo-trapped with N2 at − 195 °C. Several desorption times were tested, and the best results were obtained at 15 min of desorption time.

The chromatographic separation of the pyrolysis products was performed on a fused silica capillary column HP-5MS UI (5% diphenyl–95% dimethyl-polysiloxane, 30 m − 0.25 mm i.d., 0.25-μm film thickness, J&W Scientific, Agilent Technologies), preceded by 2 m of deactivated fused silica pre-column with an internal diameter of 0.32 mm. The chromatographic conditions for the analysis were 35 °C held for 6 min, 20 °C/min to 310 °C held for 40 min. The helium (99.9995% purity) gas flow was set in constant flow mode at 1.0 mL/min. The mass spectrometer was operated in EI positive mode (70 eV, scanning m/z 35–700). Due to the use of a single quadrupole detector, we adopted a combined selected ion monitoring (SIM) and full scan method for the mass spectrometric acquisition. The SIM parameters are reported in Table S.1 in the Supporting Information.

Results and discussion

Method validation

The calibration curves for the 28 pollutants were obtained by diluting the concentrate standard solution in 50 ml of bidistilled water and adding the deuterated and mass-labeled internal standards mix for quality control and assurance. The curves were obtained in the range of 25–250 ng/L. Table 1 shows the equations obtained for PAHs and PCBs. Figure 2 shows the calibration curves obtained for a low and a high molecular weight PAH, naphthalene, and benzo[a]pyrene, and PCB132, respectively. All the curves were characterized by R2 values in the range of 0.9823–0.9975, showing a good linearity.

Table 1.

Calibration curves, limit of detection (LOD), and quantitation (LOQ), intra- and interday coefficients of variation (CV%), and quantitative results obtained for the river sample

Analytes Calibration curves LOD (ng/L) LOQ (ng/L) Recovery (%) Reproducibility River sample (ng/L)
Slope Intercept R2 CV% intra CV% inter
Naphthalene 82,887  − 628 0.9955 2.1 7.0 97 5.0 7.1 18
2-Methylnaphthalene 49,905  − 91 0.9969 1.9 6.3 100 4.2 7.2 17
Acenaphthylene 119,254  − 238 0.9970 2.3 7.7 97 4.5 6.5  < LOD
Acenaphthene 60,575 321 0.9907 2.5 8.5 101 5.0 7.2 9.0
Fluorene 134,092 304 0.9968 1.3 4.3 101 3.5 7.2 8.0
Phenanthrene 279,519  − 3044 0.9885 2.7 9.0 110 1.3 2.6  < LOD
Anthracene 291,934  − 3426 0.9883 1.8 6.0 108 1.7 0.9  < LOD
Fluoranthene 279,241 2414 0.9918 0.6 1.9 103 1.1 5.4 2.0
Pyrene 287,887 2592 0.9913 0.9 3.1 105 0.9 5.5  < LOD
Benz[a]anthracene 131,750 707 0.9965 2.4 8.1 102 1.7 2.8  < LOQ
Chrysene 285,155  − 20 0.9952 2.5 8.5 102 1.5 3.5  < LOD
Benzo[b]fluoranthene 32,777 550 0.9909 1.5 4.9 98 2.0 5.3 0.011
Benzo[k]fluoranthene 78,576 1883 0.9937 1.5 5.0 102 2.4 4.1  < LOQ
Benzo[e]pyrene 53,328 1932 0.9910 1.5 5.1 101 1.4 5.2 6.0
Benzo[a]pyrene 74,549 1741 0.9955 1.5 4.9 103 1.1 2.1 5.0
Perylene 100,716 1447 0.9950 1.5 5.1 98 0.6 4.3 7.0
Indeno[1,2,3-c,d]pyrene 409,025  − 1148 0.9892 1.1 3.7 104 1.6 2.2  < LOQ
Dibenz[a,h]anthracene 352,126  − 690 0.9872 1.6 5.4 96 4.1 6.0  < LOQ
Benzo[g,h,i]perylene 405,676 2878 0.9823 1.4 4.6 104 0.5 3.1  < LOQ
PCB 15 126,024 1259 0.9918 1.5 5.1 100 2.3 6.0 5.0
PCB 31 90,579  − 233 0.9970 1.5 5.0 101 0.7 4.8  < LOQ
PCB 99 39,955 182 0.9947 0.9 2.9 99 4.1 5.0 1.4
PCB 89 + 113 + 110 96,210  − 1113 0.9959 0.9 3.1 97 1.1 2.6 4.0
PCB 158 20,085 171 0.9943 1.9 6.5 99 2.7 4.9  < LOD
PCB 149 19,413 67 0.9851 0.9 2.9 97 1.8 2.8 3.0
PCB151 16,981 162 0.9875 1.0 3.2 97 2.7 3.7 3.0
PCB 156 48,344  − 412 0.9975 1.0 3.2 99 1.6 3.3  < LOD
PCB 132 9894 160 0.9951 0.9 3.1 99 2.8 4.5  < LOQ

Fig. 2.

Fig. 2

Calibration curves obtained for naphthalene, benzo[a]pyrene, and PCB132

Limits of detection (LODs) and quantification (LOQs) of PAHs and PCBs were evaluated on water blanks according to the ICH guidelines. Table 1 reports the limits of detection and quantification obtained for the method validation.

For both low and high molecular weight PAHs, the LODs were in the range of 0.9 and 2.7 ng/L, while the LOQs were lower than 9.0 ng/L. The method limits obtained for both the classes of PAHs did not show any significant differences, excluding any possible discrimination associated with their different molecular weights.

The limits obtained for PCBs were in a similar range to those obtained for the PAHs, with values lower than 1.9 ng/L for the LODs and 6.5 ng/L for the LOQs.

Intraday and interday repeatability was evaluated on a diluted standard water solution with a final concentration of 100 ng/L for the analytes. The coefficients of variations obtained for all the 28 pollutants are reported in Table 1. For the PAHs, the intraday CV% was lower than 5.0%, while the interday values were lower than 7.2%. The values obtained for the PCBs were relatively lower than those of PAHs, with values below 4.1% for the intraday and 6.0% for the interday.

The method recovery was evaluated on a triplicate of a water solution added with the reference standard in order to obtain a final concentration of PAHs and PCB of 100 ng/L. The recoveries for all the species are reported in Table 1. All the chemical species were characterized by recoveries in the range of 92–110%. A comparison of the two classes of compounds revealed that the PCBs were characterized by slightly lower recoveries, with values in the range of 97–101%.

The features of the method are consistent with those reported in the current literature for the most recent and relevant solid-phase extraction approaches used for the quantification of PAHs and PCBs in the environment (Table 2) (Baktash and Bagheri, 2017, Domínguez et al. 2018; Li et al. 2021; Peng et al. 2022; Roostaie et al. 2018; Sun et al. 2021; Tian et al. 2019, 2022; Xiao et al. 2016).

Table 2.

Comparison of the Chemisorber approach features with the latest and more relevant approaches based on solid-phase extraction reported in literature

Extraction approach Analytes Extraction modes Analytical methods LOD Ref
Magic Chemisorber® (PDMS, 500-µm thickness) PAHs + PCBs Immersion Py-GC–MS 0.9–2.7 ng/L -
SPME based on a chitosan-crosslinked graphene oxide aerogel stationary phase PAHs + PCBs Immersion Desorption in the GC–MS injector 0.02–1.28 ng/L Peng et al. (2022)
Magnetic solid-phase extraction based on Fe3O4@SiO2@CTS nano adsorbent PCBs Immersion Desorption in the GC–MS injector 20 ng/L Tian et al. (2022)
SPME with superhydrophobic silica aerogel stationary phase PCBs Immersion Desorption in the GC–MS injector 100–1200 ng/L Baktash and Bagheri (2017)
SPME with organic–inorganic hybrid silica aerogel stationary phase PAHs Immersion Desorption in the GC-FID injector 1.0–30 ng/L Tian et al. (2019)
SPME with poly(ionic liquid)-hybridized silica aerogel stationary phase PAHs Immersion Desorption in the GC-FID injector 1.0–10 ng/L Sun et al. (2021)
NTD with triethylchlorosilane-modified nanoporous silica aerogel stationary phase PCBs Headspace Desorption in the GC–MS injector 0.3–1.0 ng/L Roostaie et al. (2018)
PDMS/MOF-coated stir bar PCBs Immersion Injection in the GC-FPD after solvent recovery 48–220 ng/L Xiao et al. (2016)
SPME with hypercrosslinked polymer (HCP) stationary phase PAHs Headspace Desorption in the GC–MS injector 2.5–25 ng/L Li et al. (2021)
SPME with polyacrylate stationary phase PAHs + PCB Headspace Desorption in the GC-HRMS injector 0.05–5.0 ng/L Domínguez et al. (2018)

Extraction test on environmental samples

The Chemisorber was used to investigate a river water sample in order to evaluate the feasibility of the method for the characterization and quantification of PAHs and PCBs in real environmental samples. The concentrations of the pollutants detected are reported in Table 1. A field blank was prepared and pretreated as the environmental sample to evaluate the possible unforeseen presence of other contaminants during the method validation.

Interestingly, besides the 28 target analytes, the chromatograms were also characterized by the presence of other chemical species. The analysis revealed the presence of traces of several chemical species which we did not validate with our method and which were not present in the blanks. The analysis identified plasticizers, with diethyl phthalate, butyl isohexyl phthalate, and bis(2-pentyl) phthalate being the most abundant. These species are common additives used in the production of plastic objects. Together with these species, the analysis also highlighted the presence of butylhydroxytoluene and 2,4-di-tert-butylphenol, two antioxidant compounds generally used as additives in synthetic polymers. Finally, along with these chemical species, we found traces of aliphatic hydrocarbons (up to C18), and of different sterols, the most abundant being cholestadiene, cholesterol, and β-sitosterol.

The results obtained on the river sample led to the quantification of the 28 selected organic pollutants. More importantly, they highlighted how these solid-phase extraction devices can be exploited to study a larger number of analytes and enable several emerging organic contaminants, such as phthalate plasticizers and antioxidants, to be detected and quantified, in the same chromatographic run.

Conclusions

We have presented the first application of the Magic Chemisorber® with a PDMS stationary phase for the extraction and quantification of PAHs and PCBs in freshwater samples. The results showed the potential of using this extraction device directly on small volumes of water, thereby avoiding the use of solvents. The analysis of the river sample highlighted how this approach can also be used to analyze emerging organic pollutants, such as phthalate plasticizers and antioxidants.

Our results show that this approach can be used to characterize organic pollutants in a Py-GC–MS system, thus broadening the range of applications of this instrumentation beyond the traditional environmental analyses (e.g., microplastics).

Our preliminary application of this device demonstrated that the method works well, with good linearity and reproducibly, and LODs are lower than 2.7 ng/L. Our results were comparable with recent results with other methods that use solid phases developed and tailored specifically for the analysis of PAHs and PCBs.

Finally, a further optimization of the extraction conditions and the possibility to use other mass spectrometric acquisition systems, such as triple quadrupole mass spectrometer, and implementation of specific chromatographic columns will further improve the overall performance of this approach.

Supplementary Information

Below is the link to the electronic supplementary material.

Acknowledgements

The authors are grateful to the Center for Instrument Sharing of the University of Pisa (CISUP) for the access to the analytical pyrolysis-gas chromatography-mass spectrometry system.

Author contribution

JLN: conceptualization, methodology, investigation, data curation, writing original draft, supervision; GB: investigation, formal analysis, writing original draft; FM: writing review and editing, funding acquisition; AC: conceptualization, methodology, funding acquisition; SG: conceptualization, methodology, investigation, writing original draft.

Funding

Open access funding provided by Università di Pisa within the CRUI-CARE Agreement.

Data availability

The data that support the findings of this study are available from the corresponding author.

Declarations

Ethics approval and consent to participate

Not applicable.

Consent for publication

All the authors have agreed for authorship, read, and approved the manuscript, and given consent.

Competing interests

The authors declare no competing interests.

Footnotes

Publisher's note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

References

  1. Baktash MY, Bagheri H. Silica aerogel coated on metallic wire by phase separation of polystyrene for in–tube solid phase microextraction. J Chromatogr A. 2017;1500:69–75. doi: 10.1016/j.chroma.2017.04.011. [DOI] [PubMed] [Google Scholar]
  2. Domínguez I, Arrebola FJ, Gavara R, Martínez Vidal JL, Frenich AG. Automated and simultaneous determination of priority substances and polychlorinated biphenyls in wastewater using headspace solid phase microextraction and high resolution mass spectrometry. Anal Chim Acta. 2018;1002:39–49. doi: 10.1016/j.aca.2017.11.056. [DOI] [PubMed] [Google Scholar]
  3. Drábová L, Dvořáková D, Urbancová K, Gramblička T, Hajšlová J, Pulkrabová J (2022): Critical assessment of clean-up techniques employed in simultaneous analysis of persistent organic pollutants and polycyclic aromatic hydrocarbons in fatty samples. 10, 12 [DOI] [PMC free article] [PubMed]
  4. Fitzgerald L, Wikoff DS. Persistent organic pollutants. In: Wexler P, editor. Encyclopedia of toxicology (Third Edition) Oxford: Academic Press; 2014. pp. 820–825. [Google Scholar]
  5. Gutiérrez-Serpa A, Rocío-Bautista P, Pino V, Jiménez-Moreno F, Jiménez-Abizanda AI. Gold nanoparticles based solid-phase microextraction coatings for determining organochlorine pesticides in aqueous environmental samples. J Sep Sci. 2017;40:2009–2021. doi: 10.1002/jssc.201700046. [DOI] [PubMed] [Google Scholar]
  6. Huang Y-J, Lin B-S, Lee C-L, Brimblecombe P. Enrichment behavior of contemporary PAHs and legacy PCBs at the sea-surface microlayer in harbor water. Chemosphere. 2020;245:125647. doi: 10.1016/j.chemosphere.2019.125647. [DOI] [PubMed] [Google Scholar]
  7. Huo S-H, An H-Y, Yu J, Mao X-F, Zhang Z, Bai L, Huang Y-F, Zhou P-X. Pyrolytic in situ magnetization of metal-organic framework MIL-100 for magnetic solid-phase extraction. J Chromatogr A. 2017;1517:18–25. doi: 10.1016/j.chroma.2017.08.039. [DOI] [PubMed] [Google Scholar]
  8. Li J, Zhao B, Guo L, Wang Z, Wang C, Wang Z, Zhang S, Wu Q. Synthesis of hypercrosslinked polymers for efficient solid-phase microextraction of polycyclic aromatic hydrocarbons and their derivatives followed by gas chromatography-mass spectrometry determination. J Chromatogr A. 2021;1653:462428. doi: 10.1016/j.chroma.2021.462428. [DOI] [PubMed] [Google Scholar]
  9. Manoli E, Samara C. Polycyclic aromatic hydrocarbons in natural waters: sources, occurrence and analysis. TrAC, Trends Anal Chem. 1999;18:417–428. doi: 10.1016/S0165-9936(99)00111-9. [DOI] [Google Scholar]
  10. Mwanza MM, Ndunda EN, Bosire GO, Nyamori VO, Martincigh BS. Advances in sample pretreatment and detection of PCBs in the environment. J Hazard Mater. 2021;4:100028. [Google Scholar]
  11. Nakata H, Sakai Y, Miyawaki T, Takemura A. Bioaccumulation and toxic potencies of polychlorinated biphenyls and polycyclic aromatic hydrocarbons in tidal flat and coastal ecosystems of the Ariake Sea, Japan. Environ Sci Technol. 2003;37:3513–3521. doi: 10.1021/es021083h. [DOI] [PubMed] [Google Scholar]
  12. Nouri N, Khorram P, Duman O, Sibel T, Hassan S. Overview of nanosorbents used in solid phase extraction techniques for the monitoring of emerging organic contaminants in water and wastewater samples. Trends Environ Anal Chem. 2020;25:e00081. doi: 10.1016/j.teac.2020.e00081. [DOI] [PubMed] [Google Scholar]
  13. Omarova A, Bakaikina NV, Muratuly A, Kazemian H, Baimatova N. A review on preparation methods and applications of metal–organic framework-based solid-phase microextraction coatings. Microchem J. 2022;175:107147. doi: 10.1016/j.microc.2021.107147. [DOI] [Google Scholar]
  14. Pellicer-Castell E, Belenguer-Sapiña C, Amorós P, El Haskouri J, Herrero-Martínez JM, Mauri-Aucejo AR. Mesoporous silica sorbent with gold nanoparticles for solid-phase extraction of organochlorine pesticides in water samples. J Chromatogr A. 2022;1662:462729. doi: 10.1016/j.chroma.2021.462729. [DOI] [PubMed] [Google Scholar]
  15. Peng S, Huang Y, Ouyang S, Huang J, Shi Y, Tong Y-J, Zhao X, Li N, Zheng J, Zheng J, Gong X, Xu J, Zhu F, Ouyang G. Efficient solid phase microextraction of organic pollutants based on graphene oxide/chitosan aerogel. Anal Chim Acta. 2022;1195:339462. doi: 10.1016/j.aca.2022.339462. [DOI] [PubMed] [Google Scholar]
  16. Qu C, Albanese S, Lima A, Hope D, Pond P, Fortelli A, Romano N, Cerino P, Pizzolante A, De Vivo B. The occurrence of OCPs, PCBs, and PAHs in the soil, air, and bulk deposition of the Naples metropolitan area, southern Italy: implications for sources and environmental processes. Environ Int. 2019;124:89–97. doi: 10.1016/j.envint.2018.12.031. [DOI] [PubMed] [Google Scholar]
  17. Roostaie A, Bargozin H, Mohammadiazar S, Ehteshami S. Nanoporous silica aerogel modified by triethylchlorosilane as a new sorbent for the needle-trap extraction. Sep Sci Plus. 2018;1:76–82. doi: 10.1002/sscp.201700016. [DOI] [Google Scholar]
  18. Sheng Z-H, Zhan P-P, Ye M-L, Lu Y, Zhang Y, Lin Q, Zhu Y, Zhao Y-G. Reusable ionic liquid functionalized magnetic graphene oxide nanocomposite as magnetic dispersive solid phase extraction sorbent to preconcentrate polychlorinated biphenyls in seafood. Chem Pap. 2021;75:5463–5470. doi: 10.1007/s11696-021-01739-z. [DOI] [Google Scholar]
  19. Simsek I, Kuzukiran O, Yurdakok-Dikmen B, Snoj T, Filazi A. Determination of persistent organic pollutants (POPs) in propolis by solid-phase extraction (SPE) and gas chromatography – mass spectrometry (GC-MS) Anal Lett. 2021;54:1668–1682. doi: 10.1080/00032719.2020.1821208. [DOI] [Google Scholar]
  20. Song X-L, Lv H, Wang D-D, Liao K-C, Wu Y-Y, Li G-M, Chen Y. Graphene oxide composite microspheres as a novel dispersive solid-phase extraction adsorbent of bisphenols prior to their quantitation by HPLC–mass spectrometry. Microchem J. 2022;172:106920. doi: 10.1016/j.microc.2021.106920. [DOI] [Google Scholar]
  21. Sun M, Feng J, Han S, Ji X, Li C, Feng J, Sun H, Fan J. Poly (ionic liquid)-hybridized silica aerogel for solid-phase microextraction of polycyclic aromatic hydrocarbons prior to gas chromatography-flame ionization detection. Microchim Acta. 2021;188:1–9. doi: 10.1007/s00604-020-04655-3. [DOI] [PubMed] [Google Scholar]
  22. Sun M, Li C, Feng J, Sun H, Sun M, Feng Y, Ji X, Han S, Feng J. Development of aerogels in solid-phase extraction and microextraction. TrAC, Trends Anal Chem. 2022;146:116497. doi: 10.1016/j.trac.2021.116497. [DOI] [Google Scholar]
  23. Tankiewicz M, Fenik J, Biziuk M. Solventless and solvent-minimized sample preparation techniques for determining currently used pesticides in water samples: a review. Talanta. 2011;86:8–22. doi: 10.1016/j.talanta.2011.08.056. [DOI] [PubMed] [Google Scholar]
  24. Tian Y, Feng J, Wang X, Luo C, Maloko Loussala H, Sun M. An organic-inorganic hybrid silica aerogel prepared by co-precursor method for solid-phase microextraction coating. Talanta. 2019;194:370–376. doi: 10.1016/j.talanta.2018.10.056. [DOI] [PubMed] [Google Scholar]
  25. Tian Y, Xu Z, Yang Y, Wang D, Liu Z, Si X. Magnetic solid phase extraction based on Fe3O4@SiO2@CTS nano adsorbent for the sensitive detection of trace polychlorinated biphenyls in environmental water samples. Microchem J. 2022;172:106947. doi: 10.1016/j.microc.2021.106947. [DOI] [Google Scholar]
  26. Vane CH, Kim AW, Beriro DJ, Cave MR, Knights K, Moss-Hayes V, Nathanail PC. Polycyclic aromatic hydrocarbons (PAH) and polychlorinated biphenyls (PCB) in urban soils of Greater London, UK. Appl Geochem. 2014;51:303–314. doi: 10.1016/j.apgeochem.2014.09.013. [DOI] [Google Scholar]
  27. Vasseghian Y, Hosseinzadeh S, Khataee A, Dragoi E-N. The concentration of persistent organic pollutants in water resources: a global systematic review, meta-analysis and probabilistic risk assessment. Sci Total Environ. 2021;796:149000. doi: 10.1016/j.scitotenv.2021.149000. [DOI] [PubMed] [Google Scholar]
  28. Wolska L, Galer K, Górecki T, Namieśnik J. Surface water preparation procedure for chromatographic determination of polycyclic aromatic hydrocarbons and polychlorinated biphenyls. Talanta. 1999;50:985–991. doi: 10.1016/S0039-9140(99)00193-9. [DOI] [PubMed] [Google Scholar]
  29. Wu A, Zhao X, Wang J, Tang Z, Zhao T, Niu L, Yu W, Yang C, Fang M, Lv H, Liu S, Wu F. Application of solid-phase extraction based on magnetic nanoparticle adsorbents for the analysis of selected persistent organic pollutants in environmental water: a review of recent advances. Crit Rev Environ Sci Technol. 2021;51:44–112. doi: 10.1080/10643389.2020.1720493. [DOI] [Google Scholar]
  30. Xiao Z, He M, Chen B, Hu B. Polydimethylsiloxane/metal-organic frameworks coated stir bar sorptive extraction coupled to gas chromatography-flame photometric detection for the determination of organophosphorus pesticides in environmental water samples. Talanta. 2016;156–157:126–133. doi: 10.1016/j.talanta.2016.05.001. [DOI] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

Data Availability Statement

The data that support the findings of this study are available from the corresponding author.


Articles from Environmental Science and Pollution Research International are provided here courtesy of Springer

RESOURCES