Abstract
Implant placement for dental rehabilitation has gained more popularity among patients in the recent past. Dental Implants are the workhorse of dentistry. Previously, the implants were placed with the help of the traditional freehand approach. Even though the conventional technique was successful, it has his own shortcomings. Various methods have been introduced, like stent -guided implant placement and navigation guided implant placement, that enhance the precision of implant position. The three different methods for placing the implants are freehand approach, static navigation and dynamic navigation. Among these approaches, the dynamic navigation system is a promising technology in implant dentistry. The dynamic navigation system is being used successfully in various other fields and is well known for its accuracy. It gives an advantage to clinician by providing real-time three-dimensional position of implant and better clinical and patient related treatment outcomes. This review summarizes- the literature and evidence available on dynamic navigation, its potential application, advantages, disadvantages with future directions.
Keywords: Dynamic navigation, dental implants. Freehand approach, static navigation.
SUMMARY
1. Introduction
2. Surgical Navigation - Registration
3. Different methods for placing implants
3.1 Freehand approach
3.2 Static Navigation
3.3 Dynamic Navigation
3.4 Freehand approach vs dynamic navigation surgery
3.5 Static guided surgery vs dynamic navigation surgery - Experienced vs non-experienced
4. Advantages of using dynamic navigation in implantology
5. Disadvantages of dynamic navigation
6. Importance of imaging technologies
7. Patient’s perspective
8. Future of implant dentistry
9. Conclusion
1. Introduction
Placing dental implants is one of the most popular dental procedures in recent years. The field of implantology is evolving day by day. The procedure is evolving gradually from the introduction of cone beam computed tomography (CBCT) imaging in treatment planning to the use of static implant guides in placing implants. From the introduction of Cone Beam Computed Tomography (CBCT) imaging in treatment planning to the use of static implant guides in placing implants, the procedure is evolving gradually. The procedure that utilizes static guides for implant positioning and drilling is known as the static navigation procedure. The next subsequent step in the field of implant dentistry is the introduction of dynamic navigation. Dynamic navigation technology permits the surgeon to work with the patient in real-time (i.e., the surgeon can gauge the orientation of the. implant drill in the bone using preoperative CBCT image on the screen)1. This fascinating technology has been successfully used in various medical fields, including neurosurgery, orthopaedics, surgical oncology, vascular surgery, otolaryngology and plastic surgery. In dentistry, it is used in various oral surgical procedures, such as midface fracture reduction, jaw resections, orthognathic surgery and treatment of temporomandibular joint problems2,3.
The purpose of dynamic navigation is not only the accurate placement of dental implants, but, more importantly, to ensure better clinical outcomes4,5. The better clinical outcome is achieved by placing implant in ideal position, effective and efficient prosthesis, aesthetics and efficient long-term peri-implant health. Its application in implantology is discussed in detail in this review article.
2. Surgical navigation
Surgical navigation system can be compared to a global positioning system (GPS). Like GPS, it consists of three basic components: a surgical instrument that can be compared to the GPS device, a satellite-like locator that controls GPS, and a Computed Tomography (CT) /Magnetic Resonance Imaging (MRI)/CBCT projected on the screen that is parallel to that of the map. GPS receives radio signals sent by satellites and combines these particulars with laden maps to determine the position. In surgical navigation, the locator (satellite) and the probe or surgical instrument (GPS unit) can related using mechanical, electromagnetic, ultrasonographic and optical means1. Most dynamic -navigation systems for implant surgery work with optical tracking. The optical tracking system can be either active or passive. The stereo camera traces the infrared light of the active tracking system. The reflective spheres in passive tracking systems reflect the infrared light from the source back to the camera. The most commonly used method is passive optical tracking. The light emitted by a source that is present above the patient. The light is reflected from tracking arrays above the patient and the instrument being tracked. The reflected light is picked up by stereo cameras above the patient. The preoperative image of the patient ’s paired with the patient position through a process called registration1,6 (Figure 1 and Figure 2).
Figure 1. Figure 1. Navigation mechanism flowchart.

Figure 2. Figure 2. Navgation & GPS comparison.

Registration
Registration in surgical navigation is about establishing a relationship, linking the "real" coordinate system explained by the patient’s suggestion to the field and the "virtual" coordinate system of the image data. Registration is either point-based or uses surface matching routines. The surgeon virtually observes both the superimposed clinical situation and imaging data sets and can navigate both. During the registration process in implant surgery, even the depth of the drills must be registered. Registration is a process in which the preoperative CT scan is assigned to the patient using fiducial markers. The fiducial markers are stable anatomical indicators that can be cloned on the real and virtual patient. In implant surgery, the fiducial markers differ for dentulous and edentulous patients. In dentulous patients, the fiducial clip is firmly adapted to the patient's dentition. In this way, it helps to achieve a stable position and replicate the same position every time the patient brings their teeth in contact7,8. The thermoplastic material can be used as a reference clip after the patient's impression has been taken. For edentulous patients, the fiducials are placed in the patient's alveolar bone with small screws. The placement of the fiducial markers in edentulous patients is more invasive compared to dentulous patients1,6.
3. Different Methods for Placing Implants
3.1. Freehand Approach
The most commonly used technique is the freehand method. With this conventional method, the accuracy of the implants depends entirely on the skills and dexterity of the surgeon. The implant is placed by the surgeon using the opposing and adjacent teeth as a reference mark and some calibrated probes are used to measure whether appropriate height and width are present.
Figure 3. Figure 3. Different methods for placing implants.

3.2. Static Navigation
The static guided approach uses various surgical templates for implant placement. Based on the material used, the stent can be either clear vaccuform stent which is easy to fabricate, but too flexible while placing implants, which further increases inaccuracy of implant position, chemical cure acrylic stent with lead strips, which is a diagnostic stent not used for surgery, self-cure acrylic with metal sleeves and disks, which is the most accurate but expensive, inflexible and self-cure acrylic with gutta percha filled channels, these are not as good as metal sleeves9,10. Based on support, surgical guides can be tooth supported, bone- supported or mucosa supported11. These surgical templates help maintain the angulation and position of the implants in the bone. There are plaster-based surgical templates that only maintain the position of the implants without taking into account the morphology of the bone12. There are also computerised templates that maintain the position of the implants, taking into account the bone morphology. The stents with metal tubes are designed and fabricated using CT -generated computer-aided design along a surgical system that uses coordinated instruments for placing stent- guided implants13.
3.3. Dynamic Navigation
Latest approach in placement of dental implants is dynamic navigated surgery. With this approach, implants can be placed dynamically or virtually in real time14,15. Based on the X-ray image projected on the monitor, the surgeon can see the exact position of the implant on. the monitor, so he/she can assign it in real time and navigate accordingly. This approach is definitely a better option, as the surgeon can track the depth, angulation and position of the implant throughout the procedure16. To determine whether dynamic navigation is really essential for successful implant surgery, freehand dynamic navigation and static navigation are compared. This helps dentists to make evidence-based decisions17,18.
3.4. Free-Hand Approach Vs Dynamic Navigation Surgery (Table 1)
Table 1. Table 1. Freehand vs Dynamic navigation.
| S. N0 | Aydemir CA, et al 24 | March 2020 | Type of study | Primary outcome | Secondary outcome | No of implants | Comparison | System used | Site operated | Conclusion |
|---|---|---|---|---|---|---|---|---|---|---|
| 1 | Aydemir CA, et al 24 | March 2020 | RCT | Accuracy | - | 92 | Dynamic navigation vsfreehand | NavidentClaroNa v technology,Toronto, Canada | Posterior maxilla | Navigation has better accuracythan freehand |
| 2 | Chen Z, et al 25 | Dec 2018 | Prospectiv e invitro | Accuracy | Experience | 60 | Freehand vs dynamic navigation | Navident ClaroNav technology,Toronto, Canada | Not specified | Dynamic navigation is a good implanttool |
| 3 | Kramer FJ, et al 30 | Feb 2005 | Prospectiv e invitro | accuracy | - | 100 | Freehand vs dynamic navigation | DenX, Israel | Maxillary anteriors | Navigation has superior outcome |
| 4 | Hoffmann J, et al 31 | October 2005 | Prospectiv e invitro | Accuracy | Experience | 224 | Dynamic navigation vsfreehand | Vector Vision, Brain lab,Germany | - | Dynamic > freehand |
| 5. | Block MS, et al 22 | Jan 2017 | prospectiv e | Accuracy | - | 100 | Freehand vs static vsdynamic | X-guide X-Nav technology | Maxilla and mandible | Accuracy of static anddynamic same |
| 6 | Jorba-García A et al 62 | Jan 2019 | Prospectiv e in vitro | Accuracy | Experien ce of surgeon | 36 | Freehand vs dynamic navigation inexperience | Navident, ClaroNav technology,Toronto, Canada | Only mandible models | Successful method regardless ofexperience |
| 7 | Block MS, et al 4 | July 2017 | Prospectiv e study | Accuracy | - | 714 | Freehand vs dynamic navigation | Not mentioned | - | Accuracy of dynamic navigationbetter |
The freehand method is still the most commonly used method for placing implants. It does not involve any form of 3-D guided treatment planning and carries more risk of inaccurate implant placement19. Inaccuracies are the main cause of various complications such as inferior alveolar nerve injury, adjacent root injury, membrane perforation-haematoma in the floor of the mouth, fracture of implant due to off-centre loading and increased prosthetic complexity20,21. Dynamic navigation can correct the inaccuracies and has been shown to be more accurate and better than the freehand approach in several studies. Implant accuracy has been measured using different units such as deviation in coronal, apical and angular directions22,23.
In a randomised split-mouth control study conducted by Aydemir and Arisan in 32 patients, comparing freehand and dynamic, dynamic navigation device assistance provided an additional approximate accuracy of 0.7 mm linear and 5° angular24. In a cadaveric study of implant placement using flapless technique in the anterior maxilla conducted by Chen and Le et al, observed that the navigation method had greater accuracy than the freehand method25-27. Edelman et al, concluded that navigation technique may be more successful than the freehand method using a non-invasive method in a comparative study28,29.
A few laboratory studies conducted on plaster models also reflect the superiority of navigation over the freehand method in the matter of accuracy. Kramer et al. compared placement of maxillary single-tooth implants using the freehand method versus dynamic navigation, implant position variations were lower for implants placed with navigation (P < 0.05)30. In both the axial and transverse planes, implant angulations variations were lower for implants placed with a navigation protocol (P < 0.05). Difference in insertion depth of implants was smaller using navigation compared to conventional techniques. In an in vitro study, conducted by Hoffman et al., the accuracy of free hand method was inferior to the dynamic navigation31. Chang et al. observed the precision of dynamic navigation to be higher32,33. A randomised controlled trial conducted by Yotpibulwong et al in 2023, compared static and dynamic computer assisted implant surgery combined with all three surgical systems (freehand, guided and dynamic) in a total of 120 patients divided into four groups, the main parameter measured was. discrepancy in implant position and any other deviations measured at the level of platform, apex in all directions. It was found that combined static and dynamic surgery was more accurate when compared with freehand alone or static alone or dynamic alone34.
3.5. Static Guided Surgery Vs Dynamic Navigation Surgery (Table 2)
Table 2. Table 2. Static vs Dynamic Navigation.
| SN0 | Authors | Year of publicati on | Type of study | Primary outcome | Secon dary outcome | No of implants | Comparison | System used | Site operated | Conclusion |
| 1 | Kaewsiri D, et al 43 | May 2019 | RCT | Accuracy | - | 60 | Static vs dynamic navigation | Straumann system | - | Dynamic =static |
| 2 | Yimarj P, et al 45 | Dec 2020 | RCT | Accuracy of position | paralle lism | 60 | Static vs dynamic navigation | IRIS-100; EPEDinc, Taiwan | Not specified | Similar accuracy between static anddynamic system |
| 3 | Wu D, et al 46 | Dec 2020 | Retros pectiv e study | Accuracy | Experience Implant site | 38-dynamic 57- static | Static vs dynamic | DHC-DI3E,Suzhou digital healthcare, China | Teeth specified (anterior, premolar,molar) | Both accurate. No influence by experience and implant site |
| 4 | Mediavilla Guzmán A, et al 27 | Dec 2019 | RCT | Accuracy | - | 40 (20x2) | Static vs dynamic | Navident, ClaroNav, Toronto, canada | Not specified | Both static and dynamic navigation allows accurate implant placement |
| 5 | Block M, et al 22 | Jan 2017 | prospe ctive | Accuracy | - | 100 | Freehand vs static vs dynamic | X-guide X-Nav technology | Maxilla and mandible | Accuracy of static and dynamic same |
Static navigation, as the name suggests, uses static templates to guide the precise implant location and angulation. In other words, implant position cannot be changed intraoperatively with this method unless the stent is removed35. If the stent does not fit, the whole procedure has to be repeated. With this static guidance, the doctor can only use the same implant system20,29.
Static navigation, unlike the freehand method, uses computer-aided planning for implant placement, hence more accurate. Although static navigation is a potential replacement option for freehand surgery and has improved success rates, there are also some disadvantages36. There are some factors which influence implant surgery37,38. These include CBCT precision, the correspondence of the model to the CBCT file, the accuracy of the template fabrication, the tolerance of the template sleeve, the tissue support of the template, the precise fit of template, once fabricated modifications can’t be made on stent, maximun mouth, opening of the patient and surgeon’s experience with great learning curve in designing the guide29,39,40. Although dynamic navigation offers all these advantages, the accuracy of dynamic navigation compared to static navigation has not been proven statistically significant in most of the published studies. Implant site has crucial role in the success of both approaches41,42.
In a randomised control trial by Kaewsiri et al. comparing static and dynamic navigation, both showed comparable accuracy43,44. Yimraj et al. correlated static and dynamic systems with respect to accuracy, both techniques showed similar accuracy and parallelism between two implants45. Wu et al. observed static navigation to have comparable accuracy to dynamic navigation and also the experience did not have much influence on the static navigation technique46. Guzman et al. observed no significant statistical difference between the two techniques and came to the conclusion that both techniques are accurate27. Block et al. found the accuracy of static guidance comparable to that of dynamic navigation22,44.
Experienced vs. Non-Experienced. The accuracy of the implants will be higher with experienced surgeons. But with dynamic navigation surgery with the ability to work in real time, the new trainee surgeons have advantage and are able to place implants precisely47. Clinical experience has no significant impact on implant accuracy. Sun et al observed that with the help of dynamic navigation, the surgeons were able to place precise implants regardless of their clinical experience. This was also proven by several other in vitro studies48,49.
It was also highlighted that navigation can be used in training students for implants. Real-time correlation with the image on the screen allows students to get a better picture of the anatomy and also the angulation, position and depth of the hole during the learning phase50. Zhan et al. in his study attempted to evaluate the role of dynamic navigation in training dental students in implant placement51. This study concluded implant placement using dynamic navigation by students showed noteworthy improvement. They showed significant improvement in correcting implant deviations44,52. Pellegrino et al. observed that experienced surgeon’s had no influence on the accuracy by dynamic navigation. However, it was observed that the operating time was higher in the inexperienced surgeons compared to the experienced surgeons53 (Table 3).
Table 3. Table 3. Accuracy based on experience.
| A | B | C | D | E | ||||||
|---|---|---|---|---|---|---|---|---|---|---|
| SN0 | Authors | Year of publica tion | Type of study | Primary outcome | Secondary outcome | No of implants | comparison | System used | Site operated | Conclusion |
| 1 | Sun TM, et al 48 | Dec 2019 | Prospecti ve | Experienc e | Accuracy | 30 | Experienced vs inexperienced | AqNavi system, Taiwan and polarisVic ra optical trackingsystem | 11,17,26,31,36,37region | 1. Accuracy of navigation system not affected by experience2. Navigation system improves the operator accuracy |
| 2 | Pellegrino G, et al 53 | Jan 2020 | prospecti ve – in vitro | Accuracy | Operating time, Experience | 112 (28x 4) | Accuracy in operators with varying levels ofexperience | ImplaNav,Bresmed ical, Sydney,Australia | Not specified | Reliable for both experienced and novice practioners |
| 3 | Sun TM, et al 17 | Jan 2018 | Prospecti ve (in vitro) | Accuracy | Learning curve acc tooperatio n site and operatingtime | 150 | Experienced vs inexperirnced | AqNavi system, Taiwan | Specified (6 sites) | 1.The learning curve exhibited a learning plateau after 5 years. 2.Accuracy is same in maxilla andmandible |
| 4 | Stefanelli L, et al 26 | Jan 2019 | retrospec tive | accuracy | Impact of various factors on accuracy | 231 | First 50 implants vs last 50 implants | Navident, ClaroNav, Toronto, Canada | Not specified | 1.Dynamic surgical navigation is accurate 2.Accuracy of dynamic navigation improves with experience in thetechnology |
| 5 | Golob Deeb J, et al 52 | Nov 2019 | RCT | Accuracy | Surgical time | 70 (14x 5) | Accuracy of dynamic navigation guided implant among trainees | Navident dynamic guidance system | Both anterior and posterior (right and left) | Dynamic implant can improve implant surgical training in novice population |
4. Advantages of Using Dynamic Navigation in Implantology
Dynamic navigation in implantology has considerable advantages over both statically guided implants and the freehand method. Many recent clinical studies proved its benefits over other implant delivery methods54. Reliability of implant placement can be checked throughout the procedure, unlike freehand and static guided implants is single most benefit of this technique. The literature repeatedly points out the inaccuracies associated with this technique. In the case of a statically guided implant, if there is an error in the splint, the entire process is compromised. Another advantage of navigation is that most of the procedure is performed with the patient looking at the monitor. Even in the regions of aesthetic concerns like maxillary anterior by evaluating correct bucco-lingual, mesio-distal, apico-coronal dimensions of the bone and aesthetically and prosthetically planned implant can be placed using dynamic navigation system and favourable clinical and aesthetic outcomes can be expected55,56. In physiological rest position tongue is usually in rest against anterior part of hard palate, and this position has important role in speech and sleep apnea. Invasion of this space results in inadequate functional tongue space which will lead to tongue thrusting, open bite, rotations of teeth, trauma to lateral borders of tongue57-59. Risk of invading this space is possible with free handed surgery and poorly built static guided surgery which can be overcome by dynamic navigation system where there is possibility for intraoperative change of implant position60,61. Back pain, which is one of the most common occupational hazards of the operating dentist, can be avoided. Even in cases with restricted mouth opening, implants can be placed with minimal difficulty62,63. The patient's surgery can be scheduled and performed the same day without delay, without waiting for static splints to be made. With the advent of navigation, flapless surgery of implant placement can be advocated as the exact position of the drill in the bone is always visible64,65. Many studies have reported this method leads to sensible reduction of surgical time66-69.
5. Disadvantages of Dynamic Navigation
The biggest disadvantage is the cost of the system and its accessories. Even for surgeons with good experience in implant placement, fully understanding the technique takes time and requires a learning curve. Another disadvantage is that edentulous patients require additional surgical exposure for fiducial placement70,71. One major complication which has been observed frequently using this technique is the loss of connection between the sensor and the camera72. The preference for dynamic over static navigation should therefore be justified.
6. Importance of Imaging Technologies
Both 2D and 3D imaging techniques have a crucial role in implant dentistry. Commonly used imaging technologies in implant dentistry are Radio-visiography (RVG), OPG, CBCT. Though intra oral radiographs and panoramic imaging considered to be suitable imaging techniques in dentistry, but they are not as accurate as CBCT which is 3D imaging technology. And also variations in magnification of panoramic imaging is seen in different OPG machines, so these are not completely reliable. According to International Commission on Radiological Protection low radiation exposure is noticed in intraoral and panoramic techniques when compared to CBCT which has greater exposure but less than CT. According to International Commission on Radiological Protection (ICRP) to minimization of this radiation exposure is done by following two ways i.e. justification and optimization, justification means radiographs should be advised only if necessary and not be used as a routine investigation. It basically means if benefits exceeds the risk with radiation only then radiograph should be advised after taking proper history and clinical examination73. Optimization means once decision of taking radiographs has been confirmed it should be as low as reasonably achievable. It is unimaginable to perform implant placement without radiographs, the reason being there is need for information about bone quality which is measured by using Hounsfield units, bone quantity in all dimensions and to measure distance from osteotomy site to nearest anatomical structures like inferior alveolar nerve canal, mental foramen, adjacent tooth structures, incisive canal and other pathologies if exists in mandible and nasal floor, nasal cavity, maxillary sinus with its floor, septa16. Advanced implant placing techniques like static and dynamic navigation systems are dependent on CBCT, in static navigation system with the available data from CBCT is used to 3D print the template which will provide depth, position and angulation of implant are constructed74,75. In dynamic navigation system template with implant reference markers are worn by the patient through-out the image acquisition and intraoperatively these reference markers provide constant information for the accurate precise placement of implants. These freehand technique, cause accurate implant placement is most important step for survival of implant in long-term76,77.
7. Patient’s Perspective
Common complications encountered in any dental surgery are pain and discomfort of the patient in between and after the surgery, swelling or edema post operatively, hypersensitivity, high patient’s expectations. Since everything is pre-planned and organised time taken in the dynamic navigation is less comparable to static guided surgery. In most recent studies no significant difference was found when it comes to post operative pain, swelling or edema which last not more than 2 weeks in all three surgical techniques and almost comparable patient satisfaction however slight discomfort was noticed in static guided surgery group while speaking36,78.
8. Future of Implant Dentistry
Dynamic navigation system is utilizing CBCT or other radiographic imaging to position implants, but chances of errors can’t be ruled out while using radio-diagnostic technology, Positioning errors are possible, even error in the device which marks the location is also a possibility79-81. High accuracy of robotic implant placement in replacing single tooth was shown recently in a case series by Yang et al82 where robotic implant surgery was performed to replace single missing tooth in 10 selected patients without any post operative complications or adverse surgical events, the study was success in establishing the accuracy of robotic implant surgery as an alternative method to novel dynamic navigation system. Bolding et al83 made an effort to demonstrate accuracy of haptic robotic guidance in placing implants. in completely edentulous arches for implant supported prosthesis, when compared with non- robotic methods, this robotic guidance has proven to be accurate in safely and effectively placing implants, and even in highly resorbed ridges in posterior maxilla which is considered to be complex situation robotic system has been used in a preliminary research by Li et al., where zygomatic implant are placed with minimal deviation and adequate accuracy without any deviation into lateral wall of maxillary sinus84,85. A new age technology, i.e. robotic technology for placing implants, has been under study to overcome all previous downsides for instance a phantom model study conducted by Chen J et al revealed angular deviation observed in robotic system was superior to dynamic navigation system and robotic technology has promising role in future dental implantology but at present it needs more clinical trials86.
9. Conclusion
Dynamic navigation in implant surgery is undoubtedly more accurate and has success rates. The superiority of navigation over the free-hands approach is significantly higher. The static guided/static navigation approach in implant surgery is more accurate compared to the freehand approach. There are several factors that affect the reliability of static navigation. The accuracy of both dynamic and static navigation is statistically comparable in various studies. The cost of the dynamic navigation system and accessories is comparatively expensive. Limited evidence has been seen to determine better aesthetics with dynamic navigation. Placement of dental implants with conventional or dynamic navigation protocols resulted in similar postoperative levels of patient satisfaction, oedema and pain medication. So, in the future, we need more studies with a large sample size to justify the use of dynamic navigation in clinical practice for placing regular dental implants.
Acknowledgments
None
Footnotes
Conflict of interests: The authors declare no conflicts of interest regarding the content, research, or publication of this paper. There are no financial, personal, or professional relationships that could influence the work reported in this manuscript
Abbreviations: Cone Beam Computed Tomography (CBCT); Global Positioning System (GPS) ; Computed Tomography (CT); Magnetic Resonance Imaging (MRI); Radiovisiography (RVG); International Commission on Radiological Protection (ICRP).
DISCOVERIES is a peer-reviewed, open access, online, multidisciplinary and integrative journal, publishing high impact and innovative manuscripts from all areas related to MEDICINE, BIOLOGY and CHEMISTRY
References
- 1.Surgical Navigation for Oral and Maxillofacial Surgery. Demian Nagi, Pearl Craig, Woernley Timothy Charles, Wilson James, Seaman Justin. Oral and maxillofacial surgery clinics of North America. 2019;31(4):531–538. doi: 10.1016/j.coms.2019.06.001. [DOI] [PubMed] [Google Scholar]
- 2.Navigation in surgery. Mezger Uli, Jendrewski Claudia, Bartels Michael. Langenbeck's Archives of Surgery. 2013;398(4):501-514. doi: 10.1007/s00423-013-1059-4. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 3.Simultaneous Le Fort I Osteotomy and Computer-Guided Implant Placement. Benech Arnaldo, Mazzanti Carlo, Arcuri Francesco, Giarda Mariangela, Brucoli Matteo. Journal of Craniofacial Surgery. 2011;22(3):1042-1046. doi: 10.1097/SCS.0b013e318210765d. [DOI] [PubMed] [Google Scholar]
- 4.Implant Placement Is More Accurate Using Dynamic Navigation. Block Michael S., Emery Robert W., Cullum Daniel R., Sheikh Ali. Journal of Oral and Maxillofacial Surgery. 2017;75(7):1377-1386. doi: 10.1016/j.joms.2017.02.026. [DOI] [PubMed] [Google Scholar]
- 5.Prosthetically Driven, Computer‐Guided Implant Planning for the Edentulous Maxilla: A Model Study. Katsoulis Joannis, Pazera Pawel, Mericske‐Stern Regina. Clinical Implant Dentistry and Related Research. 2009;11(3):238-245. doi: 10.1111/j.1708-8208.2008.00110.x. [DOI] [PubMed] [Google Scholar]
- 6.Intraoperative navigation in oral and maxillofacial surgery. Haßfeld Stefan, Mühling Joachim, Zöller Joachim. International Journal of Oral and Maxillofacial Surgery. 1995;24(1):111-119. doi: 10.1016/s0901-5027(05)80871-9. [DOI] [PubMed] [Google Scholar]
- 7.A registration-and-fixation approach with handpiece adjustment for dynamic navigation in dental implant surgery. Wu Bin-Zhang, Sun Feng. Heliyon. 2022;8(9):e10565. doi: 10.1016/j.heliyon.2022.e10565. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 8.Accuracy of automatic and manual dynamic navigation registration techniques for dental implant surgery in posterior sites missing a single tooth: A retrospective clinical analysis. Wu Bin‐Zhang, Xue Fei, Ma Yu, Sun Feng. Clinical Oral Implants Research. 2023;34(3):221-232. doi: 10.1111/clr.14034. [DOI] [PubMed] [Google Scholar]
- 9.Use of Diagnostic and Surgical Stent: A Simplified Approach for Implant Placement. Talwar Naina, Singh Balendra Pratap, Chand Pooran, Pal U. S. The Journal of Indian Prosthodontic Society. 2010;10(4):234-239. doi: 10.1007/s13191-010-0036-7. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 10.Accuracy of static digital surgical guides for dental implants based on the guide system: A systematic review. Eftekhar Ashtiani R., Ghasemi Z., Nami M., Mighani F., Namdari M. Journal of Stomatology, Oral and Maxillofacial Surgery. 2021;122(6):600-607. doi: 10.1016/j.jormas.2020.10.010. [DOI] [PubMed] [Google Scholar]
- 11.Variety of Surgical Guides and Protocols for Bone Reduction Prior to Implant Placement: A Narrative Review. Mijiritsky Eitan, Ben Zaken Hadar, Shacham Maayan, Cinar Ihsan Caglar, Tore Cem, Nagy Katalin, Ganz Scott D. International Journal of Environmental Research and Public Health. 2021;18(5):2341. doi: 10.3390/ijerph18052341. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 12.Comparison of Different Types of Static Computer-Guided Implant Surgery in Varying Bone Inclinations. Thangwarawut Pisut, Amornvit Pokpong, Rokaya Dinesh, Kiattavorncharoen Sirichai. Materials. 2022;15(9):3004. doi: 10.3390/ma15093004. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 13.Comparison of the Accuracy of Implant Position Using Surgical Guides Fabricated by Additive and Subtractive Techniques. Henprasert Pantip, Dawson Deborah V., El‐Kerdani Tarek, Song Xuan, Couso‐Queiruga Emilio, Holloway Julie A. Journal of Prosthodontics. 2020;29(6):534-541. doi: 10.1111/jopr.13161. [DOI] [PubMed] [Google Scholar]
- 14.Use of an image-guided navigation system in dental implant surgery in anatomically complex operation sites. Sießegger Matthias, Schneider Bernd T., Mischkowski Robert A., Lazar Frank, Krug Barbara, Klesper Bernd, Zöller Joachim E. Journal of Cranio-Maxillofacial Surgery. 2001;29(5):276-281. doi: 10.1054/jcms.2001.0242. [DOI] [PubMed] [Google Scholar]
- 15.Accuracy of Dynamic Navigation for Dental Implant Placement–Model-Based Evaluation. Emery Robert W, Merritt Scott A, Lank Kathryn, Gibbs Jason D. Journal of Oral Implantology. 2016;42(5):399-405. doi: 10.1563/aaid-joi-D-16-00025. [DOI] [PubMed] [Google Scholar]
- 16.Proposal and Validation of a New Nonradiological Method for Postoperative Three-Dimensional Implant Position Analysis Based on the Dynamic Navigation System: An In Vitro Study. Ma Feifei, Liu Mingyue, Liu Xiaoqiang, Wei Tai, Liu Lilan, Sun Feng. Journal of Personalized Medicine. 2023;13(2):362. doi: 10.3390/jpm13020362. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 17.Dental implant navigation system guide the surgery future. Sun Ting‐Mao, Lan Ting‐Hsun, Pan Chin‐Yun, Lee Huey‐Er. The Kaohsiung Journal of Medical Sciences. 2017;34(1):56-64. doi: 10.1016/j.kjms.2017.08.011. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 18.Computer-aided navigation in dental implantology: 7 years of clinical experience. Ewers Rolf, Schicho Kurt, Truppe Michael, Seemann Rudolf, Reichwein Astrid, Figl Michael, Wagner Arne. Journal of Oral and Maxillofacial Surgery. 2004;62(3):329-334. doi: 10.1016/j.joms.2003.08.017. [DOI] [PubMed] [Google Scholar]
- 19.A mixed reality-based navigation method for dental implant navigation method: A pilot study. Liu Lin, Wang Xiaoyu, Guan Miaosheng, Fan Yiping, Yang Zhongliang, Li Deyu, Bai Yuming, Li Hongbo. Computers in Biology and Medicine. 2023;154:106568. doi: 10.1016/j.compbiomed.2023.106568. [DOI] [PubMed] [Google Scholar]
- 20.Comparison of the accuracy of implant position among freehand implant placement, static and dynamic computer-assisted implant surgery in fully edentulous patients: a non-randomized prospective study. Jaemsuwan S., Arunjaroensuk S., Kaboosaya B., Subbalekha K., Mattheos N., Pimkhaokham A. International Journal of Oral and Maxillofacial Surgery. 2023;52(2):264-271. doi: 10.1016/j.ijom.2022.05.009. [DOI] [PubMed] [Google Scholar]
- 21.Prevalence and risk/protective indicators of peri-implant diseases: a university-representative cross-sectional study. Romandini Mario, Lima Cristina, Pedrinaci Ignacio, Araoz Ana, Soldini Maria Costanza, Sanz Mariano. 2020 doi: 10.1111/clr.13684. [DOI] [PubMed] [Google Scholar]
- 22.Implant Placement Accuracy Using Dynamic Navigation. Block Michael, Emery Robert, Lank Kathryn, Ryan James. The International Journal of Oral & Maxillofacial Implants. 2017;32(1):92-99. doi: 10.11607/jomi.5004. [DOI] [PubMed] [Google Scholar]
- 23.Dynamic Navigation for Dental Implant Surgery. Panchal Neeraj, Mahmood Laith, Retana Armando, Emery Robert. Oral and Maxillofacial Surgery Clinics of North America. 2019;31(4):539-547. doi: 10.1016/j.coms.2019.08.001. [DOI] [PubMed] [Google Scholar]
- 24.Accuracy of dental implant placement via dynamic navigation or the freehand method: A split‐mouth randomized controlled clinical trial. Aydemir Ceyda Aktolun, Arısan Volkan. Clinical Oral Implants Research. 2019;31(3):255-263. doi: 10.1111/clr.13563. [DOI] [PubMed] [Google Scholar]
- 25.Accuracy of flapless immediate implant placement in anterior maxilla using computer‐assisted versus freehand surgery: A cadaver study. Chen Zhaozhao, Li Junying, Sinjab Khaled, Mendonca Gustavo, Yu Haiyang, Wang Hom‐Lay. Clinical Oral Implants Research. 2018;29(12):1186-1194. doi: 10.1111/clr.13382. [DOI] [PubMed] [Google Scholar]
- 26.Accuracy of a Dynamic Dental Implant Navigation System in a Private Practice. Stefanelli Luigi, DeGroot Bradley, Lipton David, Mandelaris George. The International Journal of Oral & Maxillofacial Implants. 2019;34(1):205-213. doi: 10.11607/jomi.6966. [DOI] [PubMed] [Google Scholar]
- 27.Accuracy of Computer-Aided Dynamic Navigation Compared to Computer-Aided Static Navigation for Dental Implant Placement: An In Vitro Study. Mediavilla Guzmán Alfonso, Riad Deglow Elena, Zubizarreta-Macho Alvaro, Agustín-Panadero Ruben, Hernández Montero Sofia. Journal of Clinical Medicine. 2019;8(12):2123. doi: 10.3390/jcm8122123.. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 28.Accuracy of Computer-Assisted Dynamic Navigation in Implant Placement with a Fully Digital Approach: A Prospective Clinical Trial. Edelmann Cornelia, Wetzel Martin, Knipper Anne, Luthardt Ralph G., Schnutenhaus Sigmar. Journal of Clinical Medicine. 2021;10(9):1808. doi: 10.3390/jcm10091808. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 29.Different techniques of static/dynamic guided implant surgery: modalities and indications. Vercruyssen Marjolein, Fortin Thomas, Widmann Gerlig, Jacobs Reinhilde, Quirynen Marc. Periodontology 2000. 2014;66(1):214-227. doi: 10.1111/prd.12056. [DOI] [PubMed] [Google Scholar]
- 30.Navigated vs. conventional implant insertion for maxillary single tooth replacement. Kramer Franz‐Josef, Baethge Carola, Swennen Gwen, Rosahl Steffen. Clinical Oral Implants Research. 2004;16(1):60-68. doi: 10.1111/j.1600-0501.2004.01058.x. [DOI] [PubMed] [Google Scholar]
- 31.Accuracy of navigation‐guided socket drilling before implant installation compared to the conventional free‐hand method in a synthetic edentulous lower jaw model. Hoffmann Jürgen, Westendorff Carsten, Gomez‐Roman German, Reinert Siegmar. Clinical Oral Implants Research. 2005;16(5):609-614. doi: 10.1111/j.1600-0501.2005.01153.x. [DOI] [PubMed] [Google Scholar]
- 32.Accuracy of Implant Placement with a Navigation System, a Laboratory Guide, and Freehand Drilling. Chen Chang-Kai, Yuh Da-Yo, Huang Ren-Yeong, Fu Earl, Tsai Cheng-Feng, Chiang Cheng-Yang. The International Journal of Oral & Maxillofacial Implants. 2018;33(6):1213-1218. doi: 10.11607/jomi.6585. [DOI] [PubMed] [Google Scholar]
- 33.The accuracy of single‐tooth implants placed using fully digital‐guided surgery and freehand implant surgery. Smitkarn Palita, Subbalekha Keskanya, Mattheos Nikos, Pimkhaokham Atiphan. Journal of Clinical Periodontology. 2019;46(9):949-957. doi: 10.1111/jcpe.13160. [DOI] [PubMed] [Google Scholar]
- 34.Accuracy of implant placement with a combined use of static and dynamic computer‐assisted implant surgery in single tooth space: A randomized controlled trial. Yotpibulwong Thanida, Arunjaroensuk Sirida, Kaboosaya Boosana, Sinpitaksakul Phonkit, Arksornnukit Mansuang, Mattheos Nikos, Pimkhaokham Atiphan. Clinical Oral Implants Research. 2023;34(4):330-341. doi: 10.1111/clr.14043. [DOI] [PubMed] [Google Scholar]
- 35.Reliability of Implant Placement With Stereolithographic Surgical Guides Generated From Computed Tomography: Clinical Data From 94 Implants. Ersoy Ahmet Ersan, Turkyilmaz Ilser, Ozan Oguz, McGlumphy Edwin A. Journal of Periodontology. 2008;79(8):1339-1345. doi: 10.1902/jop.2008.080059. [DOI] [PubMed] [Google Scholar]
- 36.Conventional free-hand, dynamic navigation and static guided implant surgery produce similar short-term patient-reported outcome measures and experiences. Afrashtehfar Kelvin I. Evidence-Based Dentistry. 2021;22(4):143-145. doi: 10.1038/s41432-021-0216-9. [DOI] [PubMed] [Google Scholar]
- 37.Accuracy of a dynamic navigation system for dental implantation with two different workflows and intraoral markers compared to static‐guided implant surgery: An in‐vitro study. Struwe Maximilian, Leontiev Wadim, Connert Thomas, Kühl Sebastian, Filippi Andreas, Herber Valentin, Dagassan‐Berndt Dorothea. Clinical Oral Implants Research. 2023;34(3):196-208. doi: 10.1111/clr.14030. [DOI] [PubMed] [Google Scholar]
- 38.Implant placement in the pterygoid region with dynamically navigated surgery: A clinical report. Yao Yufei, Lin Zhihui, Yang Xingmei. The Journal of Prosthetic Dentistry. 2022;128(2):125-129. doi: 10.1016/j.prosdent.2020.12.045. [DOI] [PubMed] [Google Scholar]
- 39.Bone Reduction to Facilitate Immediate Implant Placement and Loading Using CAD/CAM Surgical Guides for Patients With Terminal Dentition. Alzoubi Fawaz, Massoomi Nima, Nattestad Anders. Journal of Oral Implantology. 2016;42(5):406-410. doi: 10.1563/aaid-joi-D-16-00016. [DOI] [PubMed] [Google Scholar]
- 40.Clinical Factors Affecting the Accuracy of Guided Implant Surgery—A Systematic Review and Meta-analysis. Zhou Wenjuan, Liu Zhonghao, Song Liansheng, Kuo Chia-ling, Shafer David M. Journal of Evidence Based Dental Practice. 2018;18(1):28-40. doi: 10.1016/j.jebdp.2017.07.007. [DOI] [PubMed] [Google Scholar]
- 41.Accuracy of dental implant placement using static versus dynamic computer-assisted implant surgery: An in vitro study. Taheri Otaghsara Seyedeh Sahar, Joda Tim, Thieringer Florian Markus. Journal of Dentistry. 2023;132:104487. doi: 10.1016/j.jdent.2023.104487. [DOI] [PubMed] [Google Scholar]
- 42.Can computer‐assisted implant surgery improve clinical outcomes and reduce the frequency and intensity of complications in implant dentistry? A critical review. Pimkhaokham Atiphan, Jiaranuchart Sirimanas, Kaboosaya Boosana, Arunjaroensuk Sirida, Subbalekha Keskanya, Mattheos Nikos. Periodontology 2000. 2022;90(1):197-223. doi: 10.1111/prd.12458. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 43.The accuracy of static vs. dynamic computer‐assisted implant surgery in single tooth space: A randomized controlled trial. Kaewsiri Dechawat, Panmekiate Soontra, Subbalekha Keskanya, Mattheos Nikos, Pimkhaokham Atiphan. Clinical Oral Implants Research. 2019;30(6):505-514. doi: 10.1111/clr.13435. [DOI] [PubMed] [Google Scholar]
- 44.Accuracy of dental implant placement using augmented reality-based navigation, static computer assisted implant surgery, and the free-hand method: An in vitro study. Kivovics Márton, Takács Anna, Pénzes Dorottya, Németh Orsolya, Mijiritsky Eitan. Journal of Dentistry. 2022;119:104070. doi: 10.1016/j.jdent.2022.104070. [DOI] [PubMed] [Google Scholar]
- 45.Comparison of the accuracy of implant position for two‐implants supported fixed dental prosthesis using static and dynamic computer‐assisted implant surgery: A randomized controlled clinical trial. Yimarj Paweena, Subbalekha Keskanya, Dhanesuan Kanit, Siriwatana Kiti, Mattheos Nikos, Pimkhaokham Atiphan. Clinical Implant Dentistry and Related Research. 2020;22(6):672-678. doi: 10.1111/cid.12949. [DOI] [PubMed] [Google Scholar]
- 46.Accuracy of dynamic navigation compared to static surgical guide for dental implant placement. Wu Dong, Zhou Lin, Yang Jin, Zhang Bao, Lin Yanjun, Chen Jiang, Huang Wenxiu, Chen Yonghui. International Journal of Implant Dentistry. 2020;6(1) doi: 10.1186/s40729-020-00272-0. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 47.Accuracy and the role of experience in dynamic computer guided dental implant surgery: An in-vitro study. Jorba-Garcia A, Figueiredo R, Gonzalez-Barnadas A, Camps-Font O, Valmaseda-Castellon E. Medicina Oral Patología Oral y Cirugia Bucal. 2018:0-0. doi: 10.4317/medoral.22785. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 48.The influence of dental experience on a dental implant navigation system. Sun Ting-Mao, Lee Huey-Er, Lan Ting-Hsun. BMC Oral Health. 2019;19(1) doi: 10.1186/s12903-019-0914-2. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 49.Performance of novice versus experienced surgeons for dental implant placement with freehand, static guided and dynamic navigation approaches. Wang Xiaotong, Shujaat Sohaib, Meeus Jan, Shaheen Eman, Legrand Paul, Lahoud Pierre, Gerhardt Maurício do Nascimento, Jacobs Reinhilde. Scientific Reports. 2023;13(1) doi: 10.1038/s41598-023-29633-6. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 50.Accuracy of static computer‐assisted implant placement in long span edentulous area by novice implant clinicians: A cross‐sectional in vitro study comparing fully‐guided, pilot‐guided, and freehand implant placement protocols. Abduo Jaafar, Lau Douglas. Clinical Implant Dentistry and Related Research. 2021;23(3):361-372. doi: 10.1111/cid.12998. [DOI] [PubMed] [Google Scholar]
- 51.Evaluation of a dynamic navigation system for training students in dental implant placement. Zhan Yalin, Wang Miaozhen, Cheng Xueyuan, Li Yi, Shi Xiaorui, Liu Feng. Journal of Dental Education. 2020;85(2):120-127. doi: 10.1002/jdd.12399. [DOI] [PubMed] [Google Scholar]
- 52.Exploring training dental implant placement using computer‐guided implant navigation system for predoctoral students: A pilot study. Golob Deeb Janina, Bencharit Sompop, Carrico Caroline K., Lukic Marija, Hawkins Daniel, Rener‐Sitar Ksenija, Deeb George R. European Journal of Dental Education. 2019;23(4):415-423. doi: 10.1111/eje.12447. [DOI] [PubMed] [Google Scholar]
- 53.Dynamic Navigation in Dental Implantology: The Influence of Surgical Experience on Implant Placement Accuracy and Operating Time. An in Vitro Study. Pellegrino Gerardo, Bellini Pierantonio, Cavallini Pier Francesco, Ferri Agnese, Zacchino Andrea, Taraschi Valerio, Marchetti Claudio, Consolo Ugo. International Journal of Environmental Research and Public Health. 2020;17(6):2153. doi: 10.3390/ijerph17062153. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 54.Accuracy of dynamic navigation in implant surgery: A systematic review and meta‐analysis. Wei Shi‐Min, Zhu Yu, Wei Jian‐Xu, Zhang Chu‐Nan, Shi Jun‐Yu, Lai Hong‐Chang. Clinical Oral Implants Research. 2021;32(4):383-393. doi: 10.1111/clr.13719. [DOI] [PubMed] [Google Scholar]
- 55.A novel application of dynamic guided navigation system in immediate implant placement. Kuo Po-Jan, Lin Chi-Yu, Hung Tsung-Fu, Chiu Hsien-Chung, Kuo Hsin-Yu. Journal of Dental Sciences. 2022;17(1):354-360. doi: 10.1016/j.jds.2021.09.030. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 56.Dynamic and static computer-guided surgery using the double-factor technique for completely edentulous patients: A dental technique. Pomares-Puig Carmen, Sánchez-Garcés M. Angeles, Jorba-García Adrià. The Journal of Prosthetic Dentistry. 2022;128(5):852-857. doi: 10.1016/j.prosdent.2021.02.022. [DOI] [PubMed] [Google Scholar]
- 57.Relevance of Tongue Force on Mandibular Denture Stabilization during Mastication. Żmudzki Jarosław, Chladek Grzegorz, Krawczyk Cezary. Journal of Prosthodontics. 2017;28(1) doi: 10.1111/jopr.12719. [DOI] [PubMed] [Google Scholar]
- 58.Evaluation of the maximum isometric tongue force of healthy volunteers. Ulrich Sommer J., Birk Richard, Hörmann Karl, Stuck Boris A. European Archives of Oto-Rhino-Laryngology. 2014;271(11):3077-3084. doi: 10.1007/s00405-014-3103-6. [DOI] [PubMed] [Google Scholar]
- 59.Tongue strength of healthy young adults. TRAWITZKI L. V. V., BORGES C. G. P., GIGLIO L. D., SILVA J. B. Journal of Oral Rehabilitation. 2010;38(7):482-486. doi: 10.1111/j.1365-2842.2010.02182.x. [DOI] [PubMed] [Google Scholar]
- 60.Effect of Tongue Thrust on Implants Integration. Dal Carlo Luca, Dal Carlo Zeno, Pasqualini Marco E., Moglioni Enrico, Shulman Mike. European Journal of Medical and Health Sciences. 2022;4(3):7-12. [Google Scholar]
- 61.Maximum isometric tongue force in patients with obstructive sleep apnoea. Birk Richard, Stuck Boris A., Maurer Joachim T., Schell Angela, Müller C. Emika, Kramer Benedikt, Hoch Stephan, Sommer J. Ulrich. European Archives of Oto-Rhino-Laryngology. 2020;278(3):893-900. doi: 10.1007/s00405-020-06327-7. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 62.Accuracy assessment of dynamic computer–aided implant placement: a systematic review and meta-analysis. Jorba-García Adrià, González-Barnadas Albert, Camps-Font Octavi, Figueiredo Rui, Valmaseda-Castellón Eduard. Clinical Oral Investigations. 2021;25(5):2479-2494. doi: 10.1007/s00784-021-03833-8. [DOI] [PubMed] [Google Scholar]
- 63.Accuracy of computer-assisted surgery in immediate implant placement. Báez-Marrero Nicole, Rafel José Luis, Rodríguez-Cárdenas Yalil Augusto, Aliaga-Del Castillo Aron, Dias-Da Silveira Heraldo Luis, Arriola-Guillén Luis Ernesto. Journal of Indian Society of Periodontology. 2022;26(3):219-223. doi: 10.4103/jisp.jisp_763_20. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 64.Is computer-guided implant placement with a flapless approach more accurate than with a flapped surgical approach? Subramani Karthikeyan. Evidence-Based Dentistry. 2022;23(3):110-111. doi: 10.1038/s41432-022-0813-2. [DOI] [PubMed] [Google Scholar]
- 65.Clinical, radiographic, microbiological, and immunological outcomes of flapped vs. flapless dental implants: a prospective randomized controlled clinical trial. Tsoukaki Marina, Kalpidis Christos D. R., Sakellari Dimitra, Tsalikis Lazaros, Mikrogiorgis George, Konstantinidis Antonis. Clinical Oral Implants Research. 2012;24(9):969-976. doi: 10.1111/j.1600-0501.2012.02503.x. [DOI] [PubMed] [Google Scholar]
- 66.Flapped versus flapless surgery and delayed versus immediate loading for a four mini implant mandibular overdenture: A <scp>RCT</scp> on post‐surgical symptoms and short‐term clinical outcomes. Leles Cláudio Rodrigues, de Paula Marcella Silva, Curado Thalita Fernandes Fleury, Silva Jésio Rodrigues, Leles José Luiz Rodrigues, McKenna Gerald, Schimmel Martin. Clinical Oral Implants Research. 2022;33(9):953-964. doi: 10.1111/clr.13974. [DOI] [PubMed] [Google Scholar]
- 67.Flapless implant surgery: a 2-year follow-up study of 40 implants. Sunitha Raja V., Sapthagiri Enukurthi. Oral Surgery, Oral Medicine, Oral Pathology and Oral Radiology. 2013;116(4):e237-e243. doi: 10.1016/j.oooo.2011.12.027. [DOI] [PubMed] [Google Scholar]
- 68.Comparison of Crestal Bone Loss Around Dental Implants Placed in Healed Sites Using Flapped and Flapless Techniques: A Systematic Review. Vohra Fahim, Al‐Kheraif Abdulaziz A., Almas Khalid, Javed Fawad. Journal of Periodontology. 2015;86(2):185-191. doi: 10.1902/jop.2014.140355. [DOI] [PubMed] [Google Scholar]
- 69.Clinical Accuracy of Flapless Computer-Guided Surgery for Implant Placement in Edentulous Arches. Marinho Vieira Dalton, Sotto-Maior Bruno Salles, Villaça de Souza Barros Carlos Alberto, Simões Reis Elson, Francischone Carlos Eduardo. The International Journal of Oral & Maxillofacial Implants. 2013;28(5):1347-1351. doi: 10.11607/jomi.3156. [DOI] [PubMed] [Google Scholar]
- 70.Advantages and disadvantages of implant navigation surgery. A systematic review. Gargallo-Albiol Jordi, Barootchi Shayan, Salomó-Coll Oscar, Wang Hom-lay. Annals of Anatomy - Anatomischer Anzeiger. 2019;225:1-10. doi: 10.1016/j.aanat.2019.04.005. [DOI] [PubMed] [Google Scholar]
- 71.Current state of the art of computer‐guided implant surgery. D'haese Jan, Ackhurst Johan, Wismeijer Daniel, De Bruyn Hugo, Tahmaseb Ali. Periodontology 2000. 2016;73(1):121-133. doi: 10.1111/prd.12175. [DOI] [PubMed] [Google Scholar]
- 72.Factors influencing transfer accuracy of cone beam <scp>CT</scp>‐derived template‐based implant placement. Behneke Alexandra, Burwinkel Matthias, Behneke Nikolaus. Clinical Oral Implants Research. 2011;23(4):416-423. doi: 10.1111/j.1600-0501.2011.02337.x. [DOI] [PubMed] [Google Scholar]
- 73.Influence of 2D vs 3D imaging and professional experience on dental implant treatment planning. Fortes João Henrique, de Oliveira-Santos Christiano, Matsumoto Wilson, da Motta Raphael Jurca Gonçalves, Tirapelli Camila. Clinical Oral Investigations. 2018;23(2):929-936. doi: 10.1007/s00784-018-2511-1. [DOI] [PubMed] [Google Scholar]
- 74.The role of CBCT in implant dentistry: uses, benefits and limitations. British Dental Journal. 2020;228(7):560-561. [Google Scholar]
- 75.A Three-Dimensional (3D) Evaluation Unveiling if the Anterior Mandible Is Truly a Safe Zone for Implant Placement. Vyas Rutvi, Tadinada Aditya. Cureus. 2023 doi: 10.7759/cureus.38084. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 76.Indications for 3-D diagnostics and navigation in dental implantology with the focus on radiation exposure: a systematic review. Kunzendorf Burkhard, Naujokat Hendrik, Wiltfang Jörg. International Journal of Implant Dentistry. 2021;7(1) doi: 10.1186/s40729-021-00328-9. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 77.Cone beam computed tomography in oral implants. Ali SyedParveez, Gupta Jyoti. National Journal of Maxillofacial Surgery. 2013;4(1):2. doi: 10.4103/0975-5950.117811. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 78.Comparing p<scp>atient‐reported</scp> outcomes and experiences among static, dynamic c<scp>omputer‐aided</scp>, and conventional freehand dental implant placement: A randomized clinical trial. Engkawong Sunida, Mattheos Nikos, Pisarnturakit Pagaporn Pantumwadee, Pimkhaokham Atiphan, Subbalekha Keskanya. Clinical Implant Dentistry and Related Research. 2021;23(5):660-670. doi: 10.1111/cid.13030. [DOI] [PubMed] [Google Scholar]
- 79.Static computer‐aided, partially guided, and free‐handed implant placement: A systematic review and meta‐analysis of randomized controlled trials. Tattan Mustafa, Chambrone Leandro, González‐Martín Oscar, Avila‐Ortiz Gustavo. Clinical Oral Implants Research. 2020;31(10):889-916. doi: 10.1111/clr.13635. [DOI] [PubMed] [Google Scholar]
- 80.Although the Computer-Aided Implant Placement Technique has Statistically Significant Better Outcomes Than Partially Guided and Free-Handed Implant Placement, the Observed Clinical Outcome Measures are Similar and Insignificant. Farsai Paul S. Journal of Evidence Based Dental Practice. 2021;21(2):101538. doi: 10.1016/j.jebdp.2021.101538. [DOI] [PubMed] [Google Scholar]
- 81.Accuracy of dental implant surgery using dynamic navigation and robotic systems: An in vitro study. Tao Baoxin, Feng Yuan, Fan Xingqi, Zhuang Minjie, Chen Xiaojun, Wang Feng, Wu Yiqun. Journal of Dentistry. 2022;123:104170. doi: 10.1016/j.jdent.2022.104170. [DOI] [PubMed] [Google Scholar]
- 82.Accuracy of autonomous robotic surgery for single-tooth implant placement: A case series. Yang Shuo, Chen Jiahao, Li An, Deng Ke, Li Ping, Xu Shulan. Journal of Dentistry. 2023;132:104451. doi: 10.1016/j.jdent.2023.104451. [DOI] [PubMed] [Google Scholar]
- 83.Accuracy of haptic robotic guidance of dental implant surgery for completely edentulous arches. Bolding Scotty L., Reebye Uday N. The Journal of Prosthetic Dentistry. 2022;128(4):639-647. doi: 10.1016/j.prosdent.2020.12.048. [DOI] [PubMed] [Google Scholar]
- 84.Autonomous robotic surgery for zygomatic implant placement and immediately loaded implant-supported full-arch prosthesis: a preliminary research. Li Changjian, Wang Menglin, Deng Huanze, Li Shumao, Fang Xinyu, Liang Yijie, Ma Xihua, Zhang Yue, Li Yanfeng. International Journal of Implant Dentistry. 2023;9(1) doi: 10.1186/s40729-023-00474-2. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 85.Dynamic Navigation for Zygomatic Implants: A Case Report about a Protocol with Intraoral Anchored Reference Tool and an Up-To-Date Review of the Available Protocols. Pellegrino Gerardo, Lizio Giuseppe, Basile Francesco, Stefanelli Luigi Vito, Marchetti Claudio, Felice Pietro. Methods and Protocols. 2020;3(4):75. doi: 10.3390/mps3040075. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 86.Comparison the accuracy of a novel implant robot surgery and dynamic navigation system in dental implant surgery: an in vitro pilot study. Chen Jianping, Bai Xiaolei, Ding Yude, Shen Liheng, Sun Xin, Cao Ruijue, Yang Fan, Wang Linhong. BMC Oral Health. 2023;23(1) doi: 10.1186/s12903-023-02873-8. [DOI] [PMC free article] [PubMed] [Google Scholar]