A computer system has been used for the recording and display of data from 277 infants with respiratory illnesses consecutively admitted to a neonatal intensive care unit during a period of 25 months. Improved efficiency of data handling was demonstrated, and the system proved valuable for teaching and research.
Full text
PDF



Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Allen L. P., Blake A. M., Durbin G. M., Ingram D., Reynolds E. O., Wimberley P. D. Continuous positive airway pressure and mechanical ventilation by facemask in newborn infants. Br Med J. 1975 Oct 18;4(5989):137–139. doi: 10.1136/bmj.4.5989.137. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Allen L. P., Reynolds E. R., Rivers R. P., Le Souëf P. M., Wimberley P. D. Controlled trial of continuous positive airway pressure given by face mask for hyaline membrane disease. Arch Dis Child. 1977 May;52(5):373–378. doi: 10.1136/adc.52.5.373. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Clark J. S., Veasy L. G., Jung A. L., Jenkins J. L. Automated PO 2 , PCO 2 and pH monitoring of infants. Comput Biomed Res. 1971 Jun;4(3):262–274. doi: 10.1016/0010-4809(71)90031-0. [DOI] [PubMed] [Google Scholar]
- Conway M., Durbin G. M., Ingram D., McIntosh N., Parker D., Reynolds E. O., Soutter L. P. Continuous monitoring of arterial oxygen tension using a catheter-tip polarographic electrode in infants. Pediatrics. 1976 Feb;57(2):244–250. [PubMed] [Google Scholar]
- Farr F. L., Clark J. S., Gardner R. M., Veasy L. G. Using a dedicated small computer in conjunction with a time-shared system in a hospital intensive care unit. Comput Biomed Res. 1972 Oct;5(5):535–539. doi: 10.1016/0010-4809(72)90059-6. [DOI] [PubMed] [Google Scholar]
- Kirby R., Robison E., Schulz J., DeLemos R. A. Continuous-flow ventilation as an alternative to assisted or controlled ventilation in infants. Anesth Analg. 1972 Nov-Dec;51(6):871–875. [PubMed] [Google Scholar]
- Lewis F. J., Deller S., Quinn M., Lee B., Will R., Raines J. Continuous patient monitoring with a small digital computer. Comput Biomed Res. 1972 Aug;5(4):411–428. doi: 10.1016/0010-4809(72)90071-7. [DOI] [PubMed] [Google Scholar]
- Perlstein P. H., Edwards N. K., Atherton H. D., Sutherland J. M. Computer-assisted newborn intensive care. Pediatrics. 1976 Apr;57(4):494–501. [PubMed] [Google Scholar]