Abstract
The kidneys in term and preterm infants were visualised by real-time ultrasound scanning. A cross-sectional centile chart has been plotted for kidney length in 100 unselected infants ranging in gestational age from 26 to 42 weeks. The ratio of kidney length to crown-to-heel length appeared to remain constant despite abnormalities in intrauterine growth rate.
Full text
PDF


Images in this article
Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Hadlock F. P., Deter R. L., Carpenter R., Gonzalez E. T., Park S. K. Sonography of fetal urinary tract anomalies. AJR Am J Roentgenol. 1981 Aug;137(2):261–267. doi: 10.2214/ajr.137.2.261. [DOI] [PubMed] [Google Scholar]
- Lawson E. E., Teele R. L. Diagnosis of adrenal hemorrhage by ultrasound. J Pediatr. 1978 Mar;92(3):423–426. doi: 10.1016/s0022-3476(78)80434-x. [DOI] [PubMed] [Google Scholar]
- Lawson T. L., Foley W. D., Berland L. L., Clark K. E. Ultrasonic evaluation of fetal kidneys. Radiology. 1981 Jan;138(1):153–156. doi: 10.1148/radiology.138.1.7455076. [DOI] [PubMed] [Google Scholar]
- Rosenberg E. R., Trought W. S., Kirks D. R., Sumner T. E., Grossman H. Ultrasonic diagnosis of renal vein thrombosis in neonates. AJR Am J Roentgenol. 1980 Jan;134(1):35–38. doi: 10.2214/ajr.134.1.35. [DOI] [PubMed] [Google Scholar]