Skip to main content
British Journal of Industrial Medicine logoLink to British Journal of Industrial Medicine
. 1985 Jan;42(1):51–54. doi: 10.1136/oem.42.1.51

Occupational asthma due to an emulsified oil mist.

M S Hendy, B E Beattie, P S Burge
PMCID: PMC1007416  PMID: 3965015

Abstract

A toolsetter developed occupational asthma due to the oil mist generated by his lathe on which it was used as a coolant. The diagnosis was confirmed by serial measurements of peak expiratory flow at home and work, including a prolonged period away from work. Occupational type bronchial provocation tests were performed using the whole emulsified oil and its components separately. He reacted specifically to the whole emulsified oil and to the reodorant, a pine oil preparation. He also reacted to colophony, a constituent of the emulsifier.

Full text

PDF
52

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Burge P. S., Edge G., Hawkins R., White V., Taylor A. J. Occupational asthma in a factory making flux-cored solder containing colophony. Thorax. 1981 Nov;36(11):828–834. doi: 10.1136/thx.36.11.828. [DOI] [PMC free article] [PubMed] [Google Scholar]
  2. Burge P. S., Harries M. G., O'Brien I., Pepys J. Bronchial provocation studies in workers exposed to the fumes of electronic soldering fluxes. Clin Allergy. 1980 Mar;10(2):137–149. doi: 10.1111/j.1365-2222.1980.tb02091.x. [DOI] [PubMed] [Google Scholar]
  3. Burge P. S., O'Brien I. M., Harries M. G. Peak flow rate records in the diagnosis of occupational asthma due to colophony. Thorax. 1979 Jun;34(3):308–316. doi: 10.1136/thx.34.3.308. [DOI] [PMC free article] [PubMed] [Google Scholar]
  4. Burge P. S., O'Brien I. M., Harries M. G. Peak flow rate records in the diagnosis of occupational asthma due to isocyanates. Thorax. 1979 Jun;34(3):317–323. doi: 10.1136/thx.34.3.317. [DOI] [PMC free article] [PubMed] [Google Scholar]
  5. Fawcett I. W., Taylor A. J., Pepys J. Asthma due to inhaled chemical agents--fumes from 'Multicore' soldering flux and colophony resin. Clin Allergy. 1976 Nov;6(6):577–585. doi: 10.1111/j.1365-2222.1976.tb01944.x. [DOI] [PubMed] [Google Scholar]
  6. Oxhøj H., Andreasen H., Henius U. M. Respiratory symptoms and ventilatory lung function in machine shop workers exposed to coolant-lubricants. Eur J Respir Dis Suppl. 1982;118:85–89. [PubMed] [Google Scholar]

Articles from British Journal of Industrial Medicine are provided here courtesy of BMJ Publishing Group

RESOURCES