Abstract

Cernik, A. A., and Sayers, M. H. P. (1971).Brit. J. industr. Med.,28, 392-398. Determination of lead in capillary blood using a paper punched disc atomic absorption technique. Application to the supervision of lead workers. The presence of lead in blood is the most incontrovertible evidence of absorption but hitherto the need for venepuncture has limited its determination in the supervision of industrial workers. Micro-methods using atomic absorption spectrophotometry (AAS) have, however, made possible the development of a sufficiently reliable test using a drop of blood obtainable by ear prick for use in the field for screening purposes.

A micro-sampling method by AAS is compared with a routine polarographic procedure (POL) using venous blood (corr. coeff. = 0·990). The pipetting of microlitres of blood can be eliminated by spotting the blood onto filter paper, allowing it to dry in air, and then using a punched-out standard disc of dried blood for analysis instead. Correlation of this method (PD) with the micro-sampling technique (AAS) is good (r=0·981).

The PD method using capillary blood also correlates acceptably with the micromethod using venous blood (r = 0·913). A pilot field study using capillary blood estimated by the PD technique showed that with this method blood can be collected by ear prick in factories for monitoring workers in the lead industry, thus eliminating the need for routine venepuncture.

Full text

PDF
398

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Cernik A. A. A dry ashing method for the determination of blood lead using cathode ray polarography. Comparison with a wet ashing technique. Br J Ind Med. 1967 Oct;24(4):289–293. doi: 10.1136/oem.24.4.289. [DOI] [PMC free article] [PubMed] [Google Scholar]
  2. Delves H. T. A micro-sampling method for the rapid determination of lead in blood by atomic-absorption spectrophotometry. Analyst. 1970 May;95(130):431–438. doi: 10.1039/an9709500431. [DOI] [PubMed] [Google Scholar]
  3. Hill J. B., Palmer P. Filter paper blood collection and punching as a means of quantification. Clin Chem. 1969 May;15(5):381–389. [PubMed] [Google Scholar]
  4. Selander S., Cramér K. Determination of lead in blood by atomic absorption spectrophotometry. Br J Ind Med. 1968 Jul;25(3):209–213. doi: 10.1136/oem.25.3.209. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from British Journal of Industrial Medicine are provided here courtesy of BMJ Publishing Group

RESOURCES