Skip to main content
British Heart Journal logoLink to British Heart Journal
. 1992 Feb;67(2):170–173. doi: 10.1136/hrt.67.2.170

Use of transoesophageal echocardiography to detect left atrial thrombi before percutaneous balloon dilatation of the mitral valve: a prospective study.

W J Manning 1, G J Reis 1, P S Douglas 1
PMCID: PMC1024748  PMID: 1540437

Abstract

OBJECTIVE--Systemic emboli related to atrial thrombi are a well known complication of percutaneous balloon dilatation of the mitral valve. The presence of left atrial thrombi therefore, is believed to be a contraindication to balloon dilatation. The purpose of this study was to determine the frequency of left atrial thrombi in patients referred for balloon dilatation of the mitral valve, the added benefit of pre-procedural transoesophageal echocardiography, and to identify factors that predicted left atrial thrombi. DESIGN--Prospective study over a 14 month period of 20 consecutive patients by cross sectional transthoracic echocardiography 24-48 hours before balloon dilatation of the mitral valve and by transoesophageal echocardiography immediately before the procedure. RESULTS--One patient had a left atrial thrombus detected by transthoracic study. Two patients (10%) had left atrial thrombi identified by transoesophageal echocardiography. In both valve dilatation was not attempted and the thrombi were confirmed at surgery. The remaining 18 patients all underwent successful balloon dilatation of the mitral valve without clinical evidence of an embolic event. No association was found between patient age, mitral valve area, transmitral gradient, left atrial size, presence of atrial fibrillation, severity of mitral regurgitation, cardiac output, or the presence of left atrial swirling and an increased prevalence of atrial thrombi. CONCLUSION--Left atrial thrombi are often seen despite long term systemic anticoagulation in patients referred for balloon dilatation of the mitral valve. The frequency of unsuspected left atrial thrombi detected by transoesophageal echocardiography was similar to the reported frequency of embolic events after balloon dilatation of the mitral valve. Transoesophageal echocardiography for the identification of left atrial thrombi is strongly recommended in all patients before balloon dilatation of the mitral valve including those treated with systemic anticoagulation and those who have had a normal transthoracic echocardiographic study.

Full text

PDF
171

Images in this article

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Aschenberg W., Schlüter M., Kremer P., Schröder E., Siglow V., Bleifeld W. Transesophageal two-dimensional echocardiography for the detection of left atrial appendage thrombus. J Am Coll Cardiol. 1986 Jan;7(1):163–166. doi: 10.1016/s0735-1097(86)80275-3. [DOI] [PubMed] [Google Scholar]
  2. Castello R., Pearson A. C., Labovitz A. J. Prevalence and clinical implications of atrial spontaneous contrast in patients undergoing transesophageal echocardiography. Am J Cardiol. 1990 May 1;65(16):1149–1153. doi: 10.1016/0002-9149(90)90330-4. [DOI] [PubMed] [Google Scholar]
  3. Come P. C., Riley M. F., Diver D. J., Morgan J. P., Safian R. D., McKay R. G. Noninvasive assessment of mitral stenosis before and after percutaneous balloon mitral valvuloplasty. Am J Cardiol. 1988 Apr 1;61(10):817–825. doi: 10.1016/0002-9149(88)91073-9. [DOI] [PubMed] [Google Scholar]
  4. Daniel W. G., Nellessen U., Schröder E., Nonnast-Daniel B., Bednarski P., Nikutta P., Lichtlen P. R. Left atrial spontaneous echo contrast in mitral valve disease: an indicator for an increased thromboembolic risk. J Am Coll Cardiol. 1988 Jun;11(6):1204–1211. doi: 10.1016/0735-1097(88)90283-5. [DOI] [PubMed] [Google Scholar]
  5. Inoue K., Owaki T., Nakamura T., Kitamura F., Miyamoto N. Clinical application of transvenous mitral commissurotomy by a new balloon catheter. J Thorac Cardiovasc Surg. 1984 Mar;87(3):394–402. [PubMed] [Google Scholar]
  6. Kronzon I., Tunick P. A., Glassman E., Slater J., Schwinger M., Freedberg R. S. Transesophageal echocardiography to detect atrial clots in candidates for percutaneous transseptal mitral balloon valvuloplasty. J Am Coll Cardiol. 1990 Nov;16(5):1320–1322. doi: 10.1016/0735-1097(90)90572-7. [DOI] [PubMed] [Google Scholar]
  7. Kulick D. L., Reid C. L., Kawanishi D. T., Rahimtoola S. H. Catheter balloon commissurotomy in adults. Part II: Mitral and other stenoses. Curr Probl Cardiol. 1990 Aug;15(8):397–470. doi: 10.1016/0146-2806(90)90022-i. [DOI] [PubMed] [Google Scholar]
  8. McKay R. G., Lock J. E., Safian R. D., Come P. C., Diver D. J., Baim D. S., Berman A. D., Warren S. E., Mandell V. E., Royal H. D. Balloon dilation of mitral stenosis in adult patients: postmortem and percutaneous mitral valvuloplasty studies. J Am Coll Cardiol. 1987 Apr;9(4):723–731. doi: 10.1016/s0735-1097(87)80224-3. [DOI] [PubMed] [Google Scholar]
  9. Pearson A. C., Labovitz A. J., Tatineni S., Gomez C. R. Superiority of transesophageal echocardiography in detecting cardiac source of embolism in patients with cerebral ischemia of uncertain etiology. J Am Coll Cardiol. 1991 Jan;17(1):66–72. doi: 10.1016/0735-1097(91)90705-e. [DOI] [PubMed] [Google Scholar]
  10. Sahn D. J., DeMaria A., Kisslo J., Weyman A. Recommendations regarding quantitation in M-mode echocardiography: results of a survey of echocardiographic measurements. Circulation. 1978 Dec;58(6):1072–1083. doi: 10.1161/01.cir.58.6.1072. [DOI] [PubMed] [Google Scholar]
  11. Shrestha N. K., Moreno F. L., Narciso F. V., Torres L., Calleja H. B. Two-dimensional echocardiographic diagnosis of left-atrial thrombus in rheumatic heart disease. A clinicopathologic study. Circulation. 1983 Feb;67(2):341–347. doi: 10.1161/01.cir.67.2.341. [DOI] [PubMed] [Google Scholar]
  12. Sigel B., Coelho J. C., Spigos D. G., Flanigan D. P., Schuler J. J., Kasprisin D. O., Nyhus L. M., Capek V. Ultrasonography of blood during stasis and coagulation. Invest Radiol. 1981 Jan-Feb;16(1):71–76. doi: 10.1097/00004424-198101000-00013. [DOI] [PubMed] [Google Scholar]
  13. Vahanian A., Michel P. L., Cormier B., Vitoux B., Michel X., Slama M., Sarano L. E., Trabelsi S., Ben Ismail M., Acar J. Results of percutaneous mitral commissurotomy in 200 patients. Am J Cardiol. 1989 Apr 1;63(12):847–852. doi: 10.1016/0002-9149(89)90055-6. [DOI] [PubMed] [Google Scholar]
  14. Wilkins G. T., Weyman A. E., Abascal V. M., Block P. C., Palacios I. F. Percutaneous balloon dilatation of the mitral valve: an analysis of echocardiographic variables related to outcome and the mechanism of dilatation. Br Heart J. 1988 Oct;60(4):299–308. doi: 10.1136/hrt.60.4.299. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from British Heart Journal are provided here courtesy of BMJ Publishing Group