Abstract
Background
Superparamagnetic iron oxide nanoparticles (SPIO) have been used as a tracer for sentinel lymph node (SLN) localization in breast cancer, demonstrating comparable performance to the combination of radioisotope (RI) and blue dye (BD).
Methods
A systematic literature search and meta-analysis with subgroup and meta-regression analysis were undertaken to update the available evidence, assess technique evolution, and define knowledge gaps. Recommendations were made using the GRADE approach.
Results
In 20 comparative studies, the detection rate was 97.5 per cent for SPIO and 96.5 per cent for RI ± BD (risk ratio 1.006, 95 per cent c.i. 0.992 to 1.019; P = 0.376, high-certainty evidence). Neoadjuvant therapy, injection site, injection volume or nodal metastasis burden did not affect the detection rate, but injection over 24 h before surgery increased the detection rate on meta-regression. Concordance was 99.0 per cent and reverse concordance 97.1 per cent (rate difference 0.003, 95 per cent c.i. −0.009 to 0.015; P = 0.656, high-certainty evidence). Use of SPIO led to retrieval of slightly more SLNs (pooled mean 1.96 versus 1.89) with a higher nodal detection rate (94.1 versus 83.5 per cent; RR 1.098, 1.058 to 1.140; P < 0.001; low-certainty evidence). In meta-regression, injection over 24 h before surgery increased the SPIO nodal yield over that of RI ± BD. The skin-staining rate was 30.8 per cent (very low-certainty evidence), and possibly prevented with use of smaller doses and peritumoral injection.
Conclusion
The performance of SPIO is comparable to that of RI ± BD. Preoperative injection increases the detection rate and nodal yield, without affecting concordance. Whether skin staining and MRI artefacts are reduced by lower dose and peritumoral injection needs to be investigated.
The magnetic technique for sentinel lymph node (SLN) biopsy has gained interest and popularity in recent years. In this comprehensive systematic review and meta-analysis, the performance of the magnetic technique was comparable to that of the isotope and blue dye combination for SLN detection (97.5 versus 96.5 per cent; risk ratio 1.006, 95 per cent c.i. 0.992 to 1.019; P = 0.376). The magnetic technique provides flexibility and facilitates logistics. Further research should focus on the existing knowledge gaps, namely expansion of novel techniques such as delayed SLN biopsy and reduction of the risk of skin staining and artefacts on postoperative MRI.
Introduction
Assessment of sentinel lymph node (SLN) status remains a significant component of breast cancer management, being routine practice in the majority of patients with a clinically negative axilla1. Radioisotopes (RIs) and blue dye (BD) have been the preferred tracers for SLN localization during the past two decades. This procedure, however, poses challenges not only associated with the regulations for manipulation and disposal of the radioactive materials, but also in terms of administration logistics. Conventional tracers are subject to limitations related to patient management, especially owing to the restricted time frame from injection to surgery2. New methods have consequently been developed to fill this gap.
Superparamagnetic iron oxide nanoparticles (SPIO) have been tested as SLN localization tracer in multiple studies and meta-analyses. Many trials3–10 have shown high concordance with conventional localization techniques and non-inferiority to RI ± BD regarding the detection rate. Several studies7,10,11 have reported skin staining, mainly after breast-conserving surgery. In addition, concerns have been raised regarding potential artefacts in postoperative MRI12–15. The technique has evolved in recent years, showing promising results with smaller doses of SPIO, injected not only in the subareolar region16,17 but also close to the tumour18. The efficacy of injection in different time frames has also been tested, ranging from intraoperative administration to up to several weeks before surgery19–21. At the same time, the introduction of paramagnetic markers for the localization of impalpable lesions22,23 offers the option of an integrated platform for breast and axillary procedures24. In this setting, the only consideration is that the use of metallic instruments interferes with the magnetic signal, and so plastic or titanium instruments need to be used instead.
The aim of this systematic review and meta-analysis was to examine the available data on SPIO in breast cancer surgery, the performance of SPIO as a tracer in SLN biopsy (SLNB), and to investigate factors associated with technique refinement. Finally, the role of the magnetic technique in addressing tailored patient needs and knowledge gaps was evaluated.
Methods
Endpoints
The primary endpoint for this meta-analysis was the detection rate for SPIO per patient, defined as the proportion of patients with at least one SLN detected successfully by the magnetic technique divided by the total number of patients. As a second primary endpoint, factors that influence the detection rate were investigated. Secondary endpoints were: detection rate per SLN, defined as the proportion of SLNs detected successfully by the magnetic technique divided by the total number of SLNs retrieved; SLN yield, expressed as the average (pooled mean) number of SLNs retrieved; prevalence of SPIO-induced skin staining, defined as documented skin staining after SPIO injection and associated factors; SPIO-induced artefacts in postoperative MRI; and cost-effectiveness. Finally, in comparative studies, the concordance between SPIO and RI was analysed. For the latter, concordance was defined as the proportion of the number of patients in whom SPIO and RI were both successful, divided by the number of patients in whom RI was successful.
Reverse concordance was defined as the proportion of the number of patients in whom SPIO and RI were both successful, divided by the number of patients in whom SPIO was successful.
For tracers performing in an equivalent manner, the assumption is that they should be successful in the same patients, that is N(SPIO + RI) = NSPIO = NRI, meaning that the rate difference (RD = concordance – reverse concordance) should be 0. However, if one of the two tracers performs better than another single tracer, that is, if NRI ≠ NSPIO, then concordance rates may be high or low, although this may not be clinically relevant. Therefore, RD was selected as effect size and was retrieved from comparative studies with a paired design. Pooled proportions and risk ratios (RRs) in comparative studies, with 95 per cent confidence intervals, were calculated to express the other outcomes. In studies in which BD was used as an adjunct for both SPIO and RI, successful detection was considered with the addition of BD for both tracers.
The findings of the meta-analysis were summarized in the form of clinical questions according to the Grading of Recommendations, Assessment, Development and Evaluation (GRADE) tool25 by two authors. Lack of evidence in clinically relevant questions was defined as a knowledge gap after discussion among the authors.
Literature search
A PubMed and MEDLINE search was performed using the search terms ‘magnetic technique’, ‘superparamagnetic iron oxide nanoparticles’, ‘sentinel lymph node’, ‘breast cancer’ according to the PRISMA statement26. A parallel search of other literature sources, including abstracts from congress volumes and citation searches, was undertaken. Authors of source studies were contacted for additional data, if deemed necessary. Single-arm, prospective, and retrospective cohort studies, and comparative, randomized and non-randomized trials were included if they provided data on the primary endpoint of the meta-analysis. For comparative trials, an isotope tracer was required as control. Any studies comparing SPIO with exclusive use of BD were excluded. Preclinical data, studies with fewer than 10 participants, and studies reporting on systems that were not available commercially at the time of publication were excluded. The literature search ended in February 2022.
Data extraction and analyses
Included studies were screened independently by two authors and the data were stored in a preformed worksheet (Microsoft® Excel; Microsoft, Redmond, WA, USA). The DerSimonian Laird random-effects model was selected a priori27. Reported effect sizes were calculated from the results of the entire source study and leave-one-out meta-analyses were performed for sensitivity. Separate analyses for detection rates and in the presence of metastasis were undertaken for the available comparative studies. Heterogeneity was evaluated by means of the I2 statistic28. Subgroup and meta-regression analyses were performed for type of SPIO, type of probe, dose of SPIO, timing of SLNB (upfront or after neoadjuvant therapy), site of injection (subareolar or periareolar versus peritumoral) and timing of injection (perioperative, suggesting intraoperative and less than 24 h before surgery; preoperative, more than 24 h before surgery). For this, studies reporting on distinct subgroups were split into respective subgroups. Publication bias was examined by inspection of funnel plots and Egger’s test for small studies effect29. Meta-analyses were undertaken in Stata® release 17 (StataCorp, College Station, TX, USA). For pooled rates of proportions, such as detection rates and skin staining, single-arm studies of SPIO and the SPIO arm of comparative trials were analysed using the metaprop command30. For these studies, meta-regression was performed with the metareg command31.
Bias assessment
The Risk Of Bias In Non-randomized Studies of Interventions (ROBINS-I)32 and Methodological Index for Non-Randomized Studies (MINORS)33 tools were used to assess bias in the included comparative studies. Single-arm studies were assessed using the MINORS tool for single-arm studies. The observational studies addressing MRI outcomes were assessed by means of the Newcastle–Ottawa Scale (NOS) for cohort studies34, and the quality assessment tool for diagnostic accuracy studies (QUADAS-2) for studies of diagnostic accuracy35. These assessments were carried out by two authors and consensus was reached after discussion. For the studies reporting on detection rates, the MINORS version was selected for the manuscript, for uniformity of presentation and the conduct of meta-regression analyses that would allow insight on whether reported outcomes might be affected by study quality.
Results
The systematic literature review identified 32 studies that were appropriate for inclusion in qualitative and quantitative synthesis (Fig. S1). Twenty studies3–11,16–20,36–42 were comparative (SPIO versus RI ± BD), of which 19 undertook concomitant administration of SPIO and RI ± BD in the same patients (paired design), whereas 7 were non-comparative24,43–48. Of these, two trials10,18 overlapped as the study by Hersi et al.18 was a patient-level meta-analysis including the outcomes of Karakatsanis et al.10. The overlapping patient group was removed from the study by Hersi et al.18, to avoid duplication. Three studies36,40,48 presented dedicated data on SLNB after neoadjuvant treatment, but only one40 reported clearly on the original nodal status. Furthermore, one study41 was used only to discuss discolouration data, and four12–15 were dedicated to reporting MRI artefacts. There was only one randomized trial17, which compared different doses of SPIO; no other randomized trials comparing SPIO with RI ± BD could be retrieved. Finally, one trial (SentiNot)19 examined the role of SPIO in the context of delayed SLNB, in patients initially operated for ductal carcinoma in situ (DCIS). In this study, SPIO was injected peritumorally in the breast during the breast procedure and the patient was taken to delayed SLNB in another session, only if underlying invasive cancer was found in the specimen. The RI was injected before delayed SLNB in the previous excision site and the subareolar region or, in the event of mastectomy, intradermally near the scar or the areola19. All included studies are summarized in Tables 1 and 2, with the respective MINORS and NOS scores for study quality. A detailed assessment of study quality and the risk of bias assessed using MINORS and ROBINS-I for studies reporting on detection rates, and NOS and QUADAS-2 for studies reporting on MRI artefacts, is available in Table S1.
Table 1.
Reference | Data accrual | SLNB procedures | SPIO | Injection volume (ml) | Injection site | Timing of injection | MINORS score |
---|---|---|---|---|---|---|---|
Douek et al.3 | Prospective, non-randomized | 160 | Sienna+® | 2 ml SPIO diluted in 3 ml NaCl or local anaesthetic | Subareolar | Peroperative | 23 |
Thill et al.4 | Prospective, non-randomized | 150 | Sienna+® | 2 ml SPIO diluted in 3 ml NaCl or local anaesthetic | Subareolar | Peroperative | 22 |
Rubio et al.36‡ | Prospective, non-randomized | 30 | Sienna+® | 2 ml SPIO diluted in 3 ml NaCl or local anaesthetic | Subareolar | Peroperative | 20 |
Rubio et al.5 | Prospective, non-randomized | 120 | Sienna+® | 2 ml SPIO diluted in 3 ml NaCl or local anaesthetic | Subareolar | Peroperative | 23 |
Piñeiro-Madrona et al.6 | Prospective, non-randomized | 181 | Sienna+® | 2 ml SPIO diluted in 3 ml NaCl or local anaesthetic | Subareolar | Peroperative | 24 |
Ghilli et al.7 | Prospective, non-randomized | 197 | Sienna+® | 2 ml SPIO diluted in 3 ml NaCl or local anaesthetic | Subareolar | Peroperative | 24 |
Coufal et al.8 | Prospective, non-randomized | 20 | Sienna+® | 2 ml SPIO diluted in 3 ml NaCl or local anaesthetic | Subareolar | Peroperative | 20 |
Ahmed et al.37 | Prospective, non-randomized | 32 | Sienna+® | 0.5 ml SPIO | Peritumoral | Peroperative | 21 |
Houpeau et al.9 | Prospective, non-randomized | 108 | Sienna+® | 2 ml SPIO diluted in 3 ml NaCl or local anaesthetic | Subareolar | Peroperative | 24 |
Karakatsanis et al.10 | Prospective, non-randomized | 206 | Sienna+® | 2 ml SPIO diluted in 3 ml NaCl or local anaesthetic | Subareolar | Peroperative | 24 |
Karakatsanis et al.11* | Prospective, non-randomized | 339 | Sienna+® | 2 ml SPIO diluted in 3 ml NaCl or local anaesthetic | Subareolar/peritumoral | Peroperative/preoperative | 24 |
Karakatsanis et al.20 | Prospective, non-randomized | 12 | Sienna+® | 2 ml SPIO diluted in 3 ml NaCl or local anaesthetic | Subareolar | Preoperative | 22 |
Karakatsanis et al.19§ | Prospective, non-randomized | 40 | Sienna+® | 2 ml SPIO | Subareolar/peritumoral | Preoperative | 24 |
Alvarado et al.16 | Prospective, non-randomized | 146 | Magtrace® | 2 ml SPIO | Subareolar | Peroperative | 24 |
Taruno et al.38† | Prospective, non-randomized | 210 | Ferucarbutran | 1 ml SPIO | Subareolar | Peroperative | 24 |
Makita et al.42† | Prospective, non-randomized | 69 | Ferucarbutran | 0.5 ml SPIO | Subareolar/peritumoral | Peroperative | 22 |
Hamzah et al.39 | Prospective, non-randomized | 20 | Magtrace® | 2 ml SPIO | Subareolar | Peroperative | 20 |
Rubio et al.17 | Prospective, randomized | 135 | Magtrace® | SPIO in different doses | Subareolar | Peroperative | 24 |
Hersi et al.18 | Prospective, non-randomized | 328 | Magtrace® | SPIO in different doses | Subareolar/peritumoral | Peroperative/preoperative | 24 |
Giménez-Climent et al.40‡ | Prospective, non-randomized | 89 | Sienna+® | 2 ml SPIO diluted in 3 ml NaCl or local anaesthetic | Subareolar | Peroperative | 22 |
Wärnberg et al.41¶ | Prospective, observational | 340 | Sienna+® | 2 ml SPIO diluted in 3 ml NaCl or local anaesthetic | Subareolar/peritumoral | Peroperative/preoperative | 20 |
Head-to-head comparison between superparamagnetic iron oxide nanoparticles (SPIO) and radioisotope. All other studies had a within-patient comparison design—all patients received both tracers ± blue dye and paired comparisons were made. †Used Tokyo probe; the Sentimag® system (Endomag, Cambridge, UK) was used in all other studies. ‡Sentinel lymph node biopsy (SLNB) after neoadjuvant treatment. §Delayed SLNB after primary surgery for ductal carcinoma in situ (SentiNot study). ¶Reported only skin-staining outcomes. MINORS, Methodological Index for Non-Randomized Studies. Sienna+® (Endomag, Campbridge, UK); Magtrace® (Endomag, Cambridge, UK).
Table 2.
Reference | Data accrual | Procedures | SPIO | Injection volume (ml) | Injection site | Timing of injection | Study quality score |
---|---|---|---|---|---|---|---|
Detection rate and skin staining | |||||||
ȃHersi et al.24‡ | Prospective, observational | 32 SLNB | Magtrace® | 2 ml SPIO | Peritumoral | Peroperative | 14 |
ȃLorek et al.43§ | Retrospective | 303 SLNB | Sienna+® | 2 ml SPIO diluted in 3 ml NaCl or local anaesthetic | Subareolar | Peroperative | 11 |
ȃMan et al.44 | Retrospective | 333 SLNB | Magtrace® | 2 ml SPIO | Subareolar | Peroperative | 13 |
ȃVural and Yilmaz45 | Prospective, observational | 104 SLNB | Sienna+® | 2 ml SPIO diluted in 3 ml NaCl or local anaesthetic | Subareolar | Peroperative | 14 |
ȃBazire et al.46¶ | Retrospective | 288 SLNB | Sienna+® | 2 ml SPIO diluted in 3 ml NaCl or local anaesthetic | Subareolar | Peroperative | 9 |
ȃPohlodek et al.47‡ | Retrospective | 38 SLNB | Sienna+® | 2 ml SPIO diluted in 3 ml NaCl or local anaesthetic | Subareolar | Peroperative | 13 |
ȃKurylcio et al.48# | Retrospective | 76 SLNB | Sienna+® | 2 ml SPIO diluted in 3 ml NaCl or local anaesthetic | Subareolar | Peroperative | 10 |
SPIO artefacts on postoperative MRI | |||||||
ȃKrischer et al.12 | Retrospective | 23 MRI | Sienna+® | 2 ml SPIO diluted in 3 ml NaCl or local anaesthetic | Subareolar | Peroperative | 3† |
ȃAribal et al.13 | Retrospective | 36 MRI | Sienna+® | 2 ml SPIO diluted in 3 ml NaCl or local anaesthetic | Subareolar | Peroperative | 3† |
ȃChapman et al.14 | Retrospective | 21 | Sienna+® | 2 ml SPIO diluted in 3 ml NaCl or local anaesthetic | Subareolar | Peroperative | 3† |
ȃChristenhusz et al.15 | Retrospective | 76 | Sienna+® | 2 ml SPIO in 3 ml NaCl subareolar or 0.1 ml intratumoral | Subareolar/intratumoral | Peroperative | 5† |
Methodological Index for Non-Randomized Studies score, except †Newcastle–Ottawa Scale score. ‡Examined the combination of superparamagnetic iron oxide nanoparticles (SPIO) with a paramagnetic seed for tumour localization. §Primary endpoint was complications of SPIO sentinel lymph node dissection (SLND) procedures. ¶Primary endpoint was the safety of postoperative radiotherapy after SPIO SLND procedures. #SLND after neoadjuvant treatment. SLNB, sentinel lymph node biopsy.
Detection rate
The pooled SLN detection rate for SPIO across all studies (27 in total, 20 comparative and 7 non-comparative) was 98.7 (95 per cent c.i. 98.1 to 99.2) per cent, with low heterogeneity (I2 = 25.0 per cent, P = 0.119). For this outcome, meta-regression analysis showed that a lower MINORS score was significantly associated with higher reported detection rates (exp(b) = 0.9992, 95 per cent c.i. 0.9982 to 0.9998; P = 0.013; I2 = 16.9 per cent). Across 20 comparative studies, the pooled detection rate was 97.5 (96.8 to 98.1) per cent for SPIO and 96.5 (95.7 to 97.2) per cent for RI ± BD, but the difference was not significant (RR 1.006, 95 per cent c.i. 0.992 to 1.019; P = 0.376; I2 = 28.7 per cent) (Fig. S2). The results were independent of pN status. For pN+ disease, across 16 comparative studies the pooled detection rate was 99.4 (97.8 to 100) per cent for SPIO and 97.0 (92.8 to 99.7) per cent for RI ± BD, indicating comparable performance (RR 1.006, 0.982 to 1.031; P = 0.637; I2 = 0 per cent). Leave-one-out meta-analysis did not affect the results.
Subgroup analyses showed that probe type, SPIO type, SPIO dose, neoadjuvant therapy, and type of study design did not influence outcomes, whereas peritumoral injection was associated with a trend for better detection for SPIO over RI ± BD. SPIO demonstrated improved detection over RI ± BD after preoperative injection and in the setting of SentiNot, which examined the feasibility of delayed SLNB. These effects were retained on meta-regression analysis. There was no heterogeneity (I2 = 0 per cent). The results are summarized in Table 3.
Table 3.
Subgroup analysis | Meta-regression analysis | |||
---|---|---|---|---|
Risk ratio | P | Coefficient b | P | |
Probe | ||||
ȃSentimag® | 1.007 (0.994, 1.019) | 0.289 | ||
ȃTokyo probe | 1.003 (0.924, 1.088) | 0.941 | ||
SPIO | ||||
ȃFerucarbutran | 1.003 (0.924, 1.088) | 0.941 | ||
ȃMagtrace® | 1.010 (0.992, 1.029) | 0.277 | ||
ȃSienna + ® | 1.004 (0.988, 1.021) | 0.598 | ||
Injection site | –0.0083 (–0.0663, 0.0498)* | 0.781 | ||
ȃSubareolar | 1.000 (0.991, 1.010) | 0.957 | ||
ȃPeritumoral | 1.118 (0.982, 1.272) | 0.091 | ||
Timing of injection | 0.0544 (0.0042, 0.1045)† | 0.034 | ||
ȃPeroperative | 0.999 (0.990, 1.008) | 0.819 | ||
ȃPreoperative | 1.116 (1.020, 1.222) | 0.017 | ||
Setting | ||||
ȃAfter neoadjuvant therapy | 1.021 (0.975, 1.069) | 0.375 | ||
ȃUpfront | 1.005 (0.992, 1.018) | 0.442 | ||
Comparison | ||||
ȃPaired | 1.007 (0.995, 1.020) | 0.251 | ||
ȃUnpaired | 0.956 (0.893, 1.024) | 0.197 | ||
Subgroup | –0.3627 (–0.5967, –0.1287)‡ | 0.002 | ||
ȃStandard SLNB | 1.002 (0.993, 1.011) | 0.661 | ||
ȃDelayed SLNB | 1.528 (1.216, 1.922) | < 0.001 | ||
Injection volume (ml) | ||||
ȃ0.5 | 1.032 (0.981, 1.086) | 0.227 | ||
ȃ1.0 | 1.016 (0.968, 1.067) | 0.522 | ||
ȃ1.5 | 0.988 (0.959, 1.017) | 0.407 | ||
ȃ2.0 | 1.042 (0.974, 1.115) | 0.231 | ||
ȃ5.0 | 1.000 (0.988, 1.013) | 0.959 |
Values in parentheses are 95% confidence intervals. Coefficient for *subareolar injection, †preoperative injection or ‡standard sentinel lymph node dissection. SPIO, superparamagnetic iron oxide nanoparticles; SLNB, sentinel lymph node biopsy.
Nodal retrieval and nodal detection rate
Data from 24 studies were available for this analysis. In crude analysis, the pooled mean number of SLNs retrieved per procedure with the magnetic technique was 2.3. The pooled nodal detection rate was 96.0 (95 per cent c.i. 93.5 to 98.1) per cent, but the results were highly heterogeneous (I2 = 95.3 per cent). No subgroup analyses were attempted.
Across 19 comparative studies, the nodal detection rate was significantly higher for SPIO than for RI ± BD (94.1 (91.8 to 96.1) versus 83.5 (78.7 to 87.9) per cent; RR 1.098, 95 per cent c.i. 1.058 to 1.140; P < 0.001), but with marked heterogeneity (I2 = 85.2 per cent) (Fig. S3). Leave-one-out meta-analysis did not change the outcome. However, crude pooled analysis showed that this difference was not clinically relevant when examining the pooled mean number of SLNs identified and excised for SPIO and RI ± BD (1.93 versus 1.85 respectively). In meta-regression analysis, use of the Sentimag® probe, preoperative SPIO injection, SLND after neoadjuvant therapy, and delayed SLNB were associated with a higher nodal detection rate for SPIO over RI ± BD (Table 4). Type of SPIO, SPIO dose, SPIO injection site, and type of study (paired versus non-paired comparative) were not significant. There was high heterogeneity (I2 = 70.0 per cent) and the Egger test demonstrated a small studies effect (β1 = 1.83, P < 0.001), which mandates that these findings are interpreted with caution.
Table 4.
Subgroup analysis | Meta-regression analysis | |||
---|---|---|---|---|
Risk ratio | P | Coefficient b | P | |
Probe | 0.3566 (0.1641, 0.5490)* | <0.001 | ||
ȃSentimag® | 1.072 (1.038, 1.108) | <0.001 | ||
ȃTokyo probe | 1.456 (1.318, 1.608) | <0.001 | ||
SPIO | −0.0019 (−0.1593, 0.1555) | 0.981 | ||
ȃFerucarbutran | 1.456 (1.318, 1.608) | <0.001 | ||
ȃMagtrace® | 1.066 (1.010, 1.126) | 0.021 | ||
ȃSienna+® | 1.078 (1.032, 1.126) | 0.001 | ||
Injection site | 0.0395 (−0.1173, 0.1963) | 0.622 | ||
ȃPeritumoral | 1.303 (1.008, 1.683) | 0.043 | ||
ȃSubareolar | 1.082 (1.043, 1.122) | <0.001 | ||
Timing of injection | 0.1473 (0.0371, 0.2574)† | 0.009 | ||
ȃPreoperative | 1.284 (1.095, 1.507) | 0.002 | ||
ȃPeroperative | 1.070 (1.033, 1.109) | <0.001 | ||
Setting | −0.1179 (−0.2231, −0.0127)‡ | 0.028 | ||
ȃUpfront | 1.078 (1.039, 1.118) | <0.001 | ||
ȃAfter neoadjuvant therapy | 1.308 (0.894, 1.912) | 0.167 | ||
Comparison | −0.1258 (−0.2685, 0.0169) | 0.084 | ||
ȃPaired | 1.097 (1.057, 1.139) | <0.001 | ||
ȃUnpaired | 0.930 (0.841, 1.029) | 0.158 | ||
Subgroup | −0.8075 (–1.2011, –0.4139)§ | <0.001 | ||
ȃStandard SLNB | 1.080 (1.044, 1.118) | <0.001 | ||
ȃDelayed SLNB | 2.571 (1.788, 3.699) | <0.001 | ||
Injection volume (ml) | 0.0092 (–0.0365, 0.05489) | 0.693 | ||
ȃ0.5 | 1.188 (0.796, 1.772) | 0.400 | ||
ȃ1.0 | 1.128 (1.053, 1.207) | 0.001 | ||
ȃ1.5 | 1.001 (0.926, 1.083) | 0.970 | ||
ȃ2.0 | 1.175 (1.025, 1.346) | 0.021 | ||
ȃ5.0 | 1.069 (1.031, 1.110) | <0.001 |
Values in parentheses are 95% confidence intervals. Coefficient for *Tokyo probe, †preoperative injection, ‡upfront surgery or §standard sentinel lymph node biopsy. SPIO, superparamagnetic iron oxide nanoparticles; SLNB, sentinel lymph node biopsy.
Concordance
Only 19 studies with a paired design were appropriate for examination of concordance. The pooled concordance rate () was 99.0 (95 per cent c.i. 98.2 to 99.6) per cent (I2 = 34.2 per cent, P = 0.073) and the reverse concordance rate () was 97.1 (95.2 to 98.6) per cent (I2 = 75.0 per cent, P < 0.001). The pooled difference was −0.003 (95 per cent c.i. −0.009 to 0.015; P = 0.656), with moderate heterogeneity (I2 = 59.5 per cent) (Fig. S4). Leave-one-out meta-analysis did not affect this outcome. In subgroup and meta-regression analysis, concordance was not affected by any factor. Reverse concordance, as expected, was decreased by the factors that increased SPIO detection over RI ± BD, subsequently affecting the RD. Indeed, subgroup and meta-regression analysis for the difference verified that preoperative SPIO injection and delayed SLN biopsy (SLNB) (SentiNot) detection affected this outcome (Table 5 and Fig. S4). The very high collinearity between SPIO detection and reverse concordance, however, limits the size of explained variance by the meta-regression model. Indeed, the adjusted R2 value was 0 per cent, suggesting that the difference between concordance and reverse concordance probably stems from the fact that the detection rate was higher with use of SPIO than with RI ± BD for preoperative SPIO detection and the SentiNot technique.
Table 5.
Subgroup analysis | Meta-regression analysis | |||
---|---|---|---|---|
Rate difference | P | Coefficient b | P | |
Probe | ||||
ȃSentimag® | −0.002 (−0.009, 0.004) | 0.502 | ||
ȃTokyo probe | −0.004 (−0.084, 0.076) | 0.922 | ||
SPIO | ||||
ȃFerucarbutran | −0.004 (−0.084, 0.076) | 0.922 | ||
ȃMagtrace® | −0.010 (−0.022, 0.001) | 0.078 | ||
ȃSienna+® | −0.004 (−0.021, 0.013) | 0.642 | ||
Injection site | ||||
ȃPeritumoral | −0.120 (−0.020, 0.063) | 0.099 | ||
ȃSubareolar | 0.001 (−0.006, 0.007) | 0.846 | ||
Timing of injection | −0.0558 (−0.0904, −0.0212)* | 0.002 | ||
ȃPreoperative | −0.122 (−0.219, −0.025) | 0.014 | ||
ȃPeroperative | 0.001 (−0.005, 0.008) | 0.655 | ||
Setting | ||||
ȃUpfront | −0.002 (−0.009, 0.004) | 0.454 | ||
ȃAfter neoadjuvant therapy | 0.021 (−0.020, 0.063) | 0.312 | ||
Subgroup | 0.2957 (0.1440, 0.4473)† | <0.001 | ||
ȃStandard SLNB | −0.0001 (−0.007, 0.006) | 0.890 | ||
ȃDelayed SLNB | −0.350 (−0.498, −0.202) | <0.001 | ||
Injection volume (ml) | ||||
ȃ0.5 | −0.035 (−0.080, 0.011) | 0.132 | ||
ȃ1.0 | −0.016 (−0.067, 0.034) | 0.524 | ||
ȃ1.5 | 0.011 (−0.022, 0.044) | 0.516 | ||
ȃ2.0 | −0.011 (−0.024, 0.003) | 0.121 | ||
ȃ5.0 | −0.001 (−0.007, 0.010) | 0.518 |
Values in parentheses are 95% confidence intervals. Coefficient for *preoperative injection or †standard sentinel lymph node dissection. SPIO, superparamagnetic iron oxide nanoparticles; SLNB, sentinel lymph node biopsy.
Skin staining and MRI artefacts
Data for skin staining were available in 12 studies5,7,9,10,13–15,33,36,38,40,44 with a maximum follow-up of 3 years. The prevalence of skin staining was 30.8 (95 per cent c.i. 21.2 to 41.2) per cent, but ranged from 0 to 84.4 per cent, with very high heterogeneity (I2 = 96 per cent) (Fig. S5). Skin staining was reported almost exclusively (over 95 per cent) after breast-conserving surgery. In subgroup analysis, the lowest discolouration rates came with a lower SPIO dose, peritumoral injection, and preoperative injection without the need to massage. No significant associations could be demonstrated on meta-regression analysis for each factor separately, suggesting that reducing skin staining is probably best achieved by a combination of these factors (Table 6). Two studies17,41 included patient-reported outcomes, which showed that the majority of patients did not consider staining to be a problem.
Table 6.
Skin staining (%) | Coefficient b | P | |
---|---|---|---|
Injection volume (ml) | −0.0061 (−0.0816, 0.0693)* | 0.863 | |
ȃ0.5 | 0 (0, 19.9) | ||
ȃ1.0 | 25.2 (9.4, 41.0) | ||
ȃ1.5 | 43.3 (37.0, 49.5) | ||
ȃ2.0 | 32.1 (26.9, 37.2) | ||
ȃ5.0 | 31.3 (20.5, 42.1) | ||
Injection site | 0.2390 (−0.2178, 0.6958)† | 0.279 | |
ȃSubareolar | 36.6 (25.8, 47.3) | ||
ȃPeritumoral | 15.4 (0, 36.2) | ||
Massage | 0.0344 (–0.4202, 0.4891)‡ | 0.873 | |
ȃYes | 34.7 (22.7, 46.6) | ||
ȃNo | 24.4 (6.3, 42.6) |
Values in parentheses are 95% confidence intervals. Coefficient for *lower superparamagnetic iron oxide nanoparticle volume, †subareolar injection or ‡perioperative injection with massage.
Four retrospective12–15 reports with a total of 97 patients were available on MRI artefacts after SPIO-guided SLND. The results were pooled from the source studies to analyse the role of SPIO dose, injection site, and type of surgery, stratified per study. Apart from six patients who received an intratumoral injection of 0.1 ml, all others had received 2 ml SPIO in a total volume of 5 ml in the subareolar area. Artefacts were present in 61 (95 per cent c.i. 50 to 70) per cent up to 46 months after SPIO administration. In univariable analyses, artefacts were more common after breast-conserving surgery than mastectomy (70 versus 21 per cent; difference 49 (95 per cent c.i. 28 to 70) per cent; P < 0.001). For the six patients with a 0.1-ml intratumoral SPIO injection, the incidence of MRI artefact was 0 per cent, compared with 65 per cent after a subareolar injection of 2 ml SPIO and 3 ml sodium chloride (difference 65 (55.0 to 75) per cent; P = 0.003). In an analysis of artefacts after breast-conserving surgery (78 patients), the effect was similar (0 versus 76 per cent; difference 76 (67 to 86) per cent; P < 0.001). Aggregated artefact rates ranged from 46 to 100 per cent among studies, owing to small numbers, high level of selection bias, and significant heterogeneity (I2 = 90 per cent). In terms of qualitative and quantitative artefact characteristics, the studies used different, non-standardized classifications, which precluded any further analyses.
Health economic outcomes
Three studies reported on health economic outcomes. In an exploratory analysis from the Swedish MONOS trial11, switching from RI to SPIO would result in an average procedure-related cost reduction of €27 (€252 to €225; reduction 10.7 (95 per cent c.i. 7.2 to 15.2) per cent), whereas with preoperative, in-office SPIO administration, the average savings were €352.7 per procedure, owing to avoidance of nuclear medicine charges and theatre delays. A pilot study from Germany49 also showed that SPIO-guided SLNB shortened the preoperative care pathway without affecting operating time or reimbursement. The authors concluded that the technique yielded the potential to reduce costs and improve patient experience. Finally, the SentiNot interim analysis19 showed that, by SPIO allowing upfront SLNB to be avoided in patients with high-risk DCIS, a mean reduction of €448 (95 per cent c.i. €151 to 746) per patient, corresponding to a reduction of 8.5 per cent (€4813 versus 5261; P = 0.003), was achieved for the entire study. This reduction was even more significant for women with DCIS (and not invasive tumours) who would have undergone SLNB (mean cost saving €1296 (€3990 versus 5286), 24.5 per cent; P < 0·001). No other relevant data could be retrieved during the systematic review.
Evidence summary, knowledge gaps, and research priorities
Summarizing the evidence according to GRADE (Table S2), in the setting of upfront SLNB for breast cancer, SPIO performed comparably and was concordant in terms of detection rate with RI ± BD, independently of nodal status (high-certainty evidence), retrieving slightly more SLNs (low-certainty evidence). The latter was an outcome with marked heterogeneity and may depend on other factors, such as differences in study protocols (for example registration of ex vivo signal with registration of more nodes as magnetic or removal of palpable lymph nodes) that are difficult to account for. Regardless, the average numbers of SLNs retrieved were similar and there should be no concern about the removal of an excessively larger number of SLNs. Interestingly, SPIO yielded a higher detection rate when administered more than 24 h before surgery, a property that should be capitalized on, as it may have the potential to provide logistical advantages, and possibly contain costs. Another point of interest from this meta-analysis is that studies with a higher risk of bias, such as retrospective analyses, and those without a control group, smaller numbers or without standardized reporting of outcomes (corresponding to a lower MINORS score), reported higher detection rates, suggesting that only well designed prospective trials are expected to improve the level of evidence for the magnetic technique.
In the present meta-analysis, skin staining after SPIO injection occurred in approximately 30 per cent of patients. The existing evidence was heterogeneous in outcomes, but also in type and duration of follow-up. Reported skin staining rates were much lower after injection of smaller volumes deep in the parenchyma and close to the tumour. The strength of recommendations is currently low owing to data heterogeneity, but, given that smaller volumes or peritumoral injection did not have adverse effects on SLN detection, this is something that should be considered. Further studies need to take these parameters into account, and provide structured follow-up and reporting of skin staining.
Regarding the presence of MRI artefacts, only retrospective reports12–14 were identified. It would appear that residual SPIO in the parenchyma is expected to produce artefacts in the ipsilateral breast and predominantly at the injection site. Reassuringly, the contralateral breast or other surrounding structures are not affected. The results of the meta-analysis suggest that a small injection volume in the part of the breast that will be removed may address this concern. The evidence is, however, very limited. The quality of the identified studies precludes definitive conclusions or clear recommendations. Therefore, prospective observational studies should examine the outcome of MRI artefacts in relation to different doses and injection sites, and interpret the findings in a standardized and clinically relevant manner. Currently, there are two ongoing prospective studies17,50 dedicated to investigating MRI artefacts after SPIO injection, one after subareolar and the other after peritumoral SPIO administration in doses of 2.0, 1.5, and 1.0 ml.
Although dedicated studies examining SPIO-guided SLND after neoadjuvant therapy were restricted, subgroup and meta-regression analyses demonstrated that SPIO performed comparably to RI in this setting. The lack of structured reports on node status before neoadjuvant therapy is a serious limitation, as no detailed conclusions can be drawn. More, well structured studies in this setting should add to the existing body of evidence. No data exist regarding the use of SPIO for SLND in pregnant patients with breast cancer, as pregnancy was an exclusion criterion in all the prospective trials identified.
Discussion
RI ± BD has long served as the standard tracer for SLNB in patients with breast cancer. Its known restrictions, including challenging logistics, restricted access and, in the case of the dye, anaphylactic reactions, have motivated research for new techniques. The magnetic technique with SPIO is one such method. Two previous meta-analyses10,51 have already shown non-inferiority and reached similar conclusions, despite using different methodology. Therein, all included studies had a paired design, that is patients acted as their own controls, and all had received a perioperative subareolar injection of 5 ml (2 ml SPIO, diluted with 3 ml sodium chloride 0.9 per cent) followed by a 5-min massage. Since then, more studies have been added to the literature, evaluating SPIO as the sole tracer for SLNB, or examining the effect of different doses, injection sites in the breast, and time frames of administration. In the present meta-analysis, data synthesis verified that SPIO performs comparably to RI ± BD, regardless of dose or injection site. Both detection rates and concordance were comparable, suggesting that SPIO is a valid alternative to RI ± BD. The difference noted in nodal detection rate suggests that SPIO retrieves more SLNs, but crude analysis showed that the numerical difference is not relevant, and that SPIO-guided SLND does not result in excessive node retrieval.
A novel finding of this meta-analysis is that the preoperative injection of SPIO is not only feasible, but also increases SLN detection. Although injection more than 24 h before surgery was shown to increase detection over peroperative or intraoperative administration, the optimal or maximum interval between SPIO administration and surgery still needs to be defined. It seems that extending the time before surgery allows increased SPIO concentration in the SLN, facilitating identification, a finding in line with experimental data52. Several studies11,18 have reported on a time frame that extends up to 27 days in upfront SLNB. This has already been capitalized on in the SentiNot study, which explored the feasibility of delayed SLNB in women with a preoperative diagnosis of DCIS, in whom successful SLNB was performed up to 47 days after SPIO injection19. This is a property unique to SPIO and further investigation in other clinical scenarios, such as the neoadjuvant therapy setting, could provide with interesting implementations, such as SPIO administration already before the induction of neoadjuvant therapy, both in terms of clinical outcomes but also in cost containment. Recently, the feasibility of minimally invasive magnetic axillary mapping was demonstrated in the phase II MagUS study53, in which a group of patients were mapped with SPIO injection before neoadjuvant therapy. At surgery when SLNB or targeted axillary dissection was performed, the magnetic SLNs were still visualized on MRI, without tracer migration, and had good concordance with the isotope.
Skin staining and MRI artefacts have been the main concern regarding the SPIO technique, mostly after breast conservation. The present results suggest that staining is less with a smaller dose and a peritumoral injection can address this, as the bulk of SPIO is removed during surgery. Because there is an absolute correlation between SPIO staining and magnetic signal10, a similar association could be expected for MRI artefacts. The available evidence, however, stems from studies with a high risk of bias, reporting outcomes after injection of 5 ml, which is no longer used. In a study from the Netherlands15, it was shown that no artefacts were present in patients who had received a peritumoral, lower-volume SPIO injection. This is in line with the hypothesis that residual SPIO is related to the presence of artefacts. Therefore, removing this area should address such concerns. However, this is only a hypothesis that needs to be confirmed; currently, this topic is viewed as the most important knowledge gap to be addressed. Results from the PostMAG MRI study50 and the SUNRISE trial17 are expected to provide more insight, as these studies are examining the same question after 2.0-, 1.5-, and 1.0-ml injections, but the injection was peritumoral in PostMAG MRI and subareolar in SUNRISE. At the same time, the results suggest that further research on SPIO is required to achieve high detection rates and, at the same time, minimize the risk of skin staining and MRI artefacts.
Apart from binary meta-analyses, the magnetic technique has shown comparable performance to RI ± BD or indocyanine green in network meta-analyses10,51,54. However, the present work provides an updated and comprehensive review of current knowledge and provides information on the outcomes associated with use of different SPIO products, probes, doses, injection timings, and injection sites, thus contributing to the refinement of the technique. The available evidence has been evaluated according to the standardized GRADE approach, which defines the level of evidence and strength of recommendations. Interestingly, the GRADE outcomes have highlighted that, although there are no clinically relevant differences in detection rates and node retrieval between comparative and non-comparative studies, the level and strength of evidence will increase only if further research is performed in well designed prospective trials, instead of small, non-controlled studies. The latter should merely serve as pilot projects that will assess the feasibility of larger trials or report on off-label uses.
Supplementary Material
Acknowledgements
The risk-of-bias plots in the supplementary material were created with the robvis tool55. The review was not registered in a public registry.
Contributor Information
Eirini Pantiora, Department for Surgical Sciences, Uppsala University, Uppsala, Sweden; Section for Breast Surgery, Department of Surgery, Uppsala University Hospital, Uppsala, Sweden.
Marios Konstantinos Tasoulis, Breast Surgery Unit, Royal Marsden NHS Foundation Trust, London, UK; Division of Breast Cancer Research, Institute of Cancer Research, London, UK.
Antonios Valachis, Department of Oncology, Örebro University Hospital, School of Medicine, Örebro University, Örebro, Sweden.
Staffan Eriksson, Section for Breast Surgery, Department of Surgery, Västmanland Hospital, Västerås, Sweden; Centre for Clinical Research, Uppsala University, Västerås, Sweden.
Thorsten Kühn, Department of Gynaecology and Obstetrics, Interdisciplinary Breast Centre, Hospital Esslingen, Esslingen, Germany.
Andreas Karakatsanis, Department for Surgical Sciences, Uppsala University, Uppsala, Sweden; Section for Breast Surgery, Department of Surgery, Uppsala University Hospital, Uppsala, Sweden.
Isabel T Rubio, Breast Surgical Unit, Clinica Universidad de Navarra, Cancer Centre University of Navarra, Madrid, Spain.
Funding
No external funding was available for the present project.
Disclosure
The authors declare no conflict of interest.
Supplementary material
Supplementary material is available at BJS online.
Data availability
The review protocol, template data collection forms, data extracted from included studies, and data used for all analyses can be accessed upon reasonable request.
References
- 1. Lyman GH, Somerfield MR, Bosserman LD, Perkins CL, Weaver DL, Giuliano AE. Sentinel lymph node biopsy for patients with early-stage breast cancer: american society of clinical oncology clinical practice guideline update. J Clin Oncol 2017;35:561–564 [DOI] [PubMed] [Google Scholar]
- 2. Ahmed M, Purushotham AD, Douek M. Novel techniques for sentinel lymph node biopsy in breast cancer: a systematic review. Lancet Oncol 2014;15:e351–e362 [DOI] [PubMed] [Google Scholar]
- 3. Douek M, Klaase J, Monypenny I, Kothari A, Zechmeister K, Brown Det al. . Sentinel node biopsy using a magnetic tracer versus standard technique: the SentiMAG multicentre trial. Ann Surg Oncol 2014;21:1237–1245 [DOI] [PubMed] [Google Scholar]
- 4. Thill M, Kurylcio A, Welter R, van Haasteren V, Grosse B, Berclaz Get al. . The central-European SentiMag study: sentinel lymph node biopsy with superparamagnetic iron oxide (SPIO) vs. radioisotope. Breast 2014;23:175–179 [DOI] [PubMed] [Google Scholar]
- 5. Rubio IT, Diaz-Botero S, Esgueva A, Rodriguez R, Cortadellas T, Cordoba Oet al. . The superparamagnetic iron oxide is equivalent to the Tc99 radiotracer method for identifying the sentinel lymph node in breast cancer. Eur J Surg Oncol 2015;41:46–51 [DOI] [PubMed] [Google Scholar]
- 6. Piñero-Madrona A, Torró-Richart JA, de León-Carrillo JM, de Castro-Parga G, Navarro-Cecilia J, Domínguez-Cunchillos Fet al. . Superparamagnetic iron oxide as a tracer for sentinel node biopsy in breast cancer: a comparative non-inferiority study. Eur J Surg Oncol 2015;41:991–997 [DOI] [PubMed] [Google Scholar]
- 7. Ghilli M, Carretta E, Di Filippo F, Battaglia C, Fustaino L, Galanou Iet al. . The superparamagnetic iron oxide tracer: a valid alternative in sentinel node biopsy for breast cancer treatment. Eur J Cancer Care (Engl) 2015;26 [DOI] [PubMed] [Google Scholar]
- 8. Coufal O, Fait V, Lžičařová E, Chrenko V, Žaloudík J. [Sentimag—the magnetic detection system of sentinel lymph nodes in breast cancer.] Rozhl Chir 2015;94:283–288 [PubMed] [Google Scholar]
- 9. Houpeau JL, Chauvet MP, Guillemin F, Bendavid-Athias C, Charitansky H, Kramar Aet al. . Sentinel lymph node identification using superparamagnetic iron oxide particles versus radioisotope: the French Sentimag feasibility trial. J Surg Oncol 2016;113:501–507 [DOI] [PubMed] [Google Scholar]
- 10. Karakatsanis A, Christiansen PM, Fischer L, Hedin C, Pistioli L, Sund Met al. . The nordic SentiMag trial: a comparison of super paramagnetic iron oxide (SPIO) nanoparticles versus Tc99 and patent blue in the detection of sentinel node (SN) in patients with breast cancer and a meta-analysis of earlier studies. Breast Cancer Res Treat 2016;157:281–294 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 11. Karakatsanis A, Daskalakis K, Stålberg P, Olofsson H, Andersson Y, Eriksson Set al. . Superparamagnetic iron oxide nanoparticles as the sole method for sentinel node biopsy detection in patients with breast cancer. Br J Surg 2017;104:1675–1685 [DOI] [PubMed] [Google Scholar]
- 12. Krischer B, Forte S, Niemann T, Kubik-Huch RA, Leo C. Feasibility of breast MRI after sentinel procedure for breast cancer with superparamagnetic tracers. Eur J Surg Oncol 2018;44:74–79 [DOI] [PubMed] [Google Scholar]
- 13. Aribal E, Çelik L, Yilmaz C, Demirkiran C, Guner DC. Effects of iron oxide particles on MRI and mammography in breast cancer patients after a sentinel lymph node biopsy with paramagnetic tracers. Clin Imaging 2021;75:22–26 [DOI] [PubMed] [Google Scholar]
- 14. Chapman MC, Lee AY, Hayward JH, Joe BN, Price ER. Superparamagnetic iron oxide sentinel node tracer injection: effects on breast MRI quality. J Breast Imaging 2020;2:577–582 [DOI] [PubMed] [Google Scholar]
- 15. Christenhusz A, Pouw JJ, Simonis FFJ, Douek M, Ahmed M, Klaase JMet al. . Breast MRI in patients after breast conserving surgery with sentinel node procedure using a superparamagnetic tracer. Eur Radiol Exp 2022;6:3. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 16. Alvarado MD, Mittendorf EA, Teshome M, Thompson AM, Bold RJ, Gittleman MAet al. . SentimagIC: a non-inferiority trial comparing superparamagnetic iron oxide versus technetium-99 m and blue dye in the detection of axillary sentinel nodes in patients with early-stage breast cancer. Ann Surg Oncol. 2019;26:3510–3516 [DOI] [PubMed] [Google Scholar]
- 17. Rubio IT, Rodriguez-Revuelto R, Espinosa-Bravo M, Siso C, Rivero J, Esgueva A. A randomized study comparing different doses of superparamagnetic iron oxide tracer for sentinel lymph node biopsy in breast cancer: the SUNRISE study. Eur J Surg Oncol 2020;46:2195–2201 [DOI] [PubMed] [Google Scholar]
- 18. Hersi AF, Pistiolis L, Luberth CD, Vikhe-Patil E, Nilsson F, Mohammed Iet al. . Article optimizing dose and timing in magnetic tracer techniques for sentinel lymph node detection in early breast cancers: the prospective multicenter sentidose trial. Cancers (Basel) 2021;13:693. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 19. Karakatsanis A, Hersi AF, Pistiolis L, Bagge RO, Lykoudis PM, Eriksson Set al. . Effect of preoperative injection of superparamagnetic iron oxide particles on rates of sentinel lymph node dissection in women undergoing surgery for ductal carcinoma in situ (SentiNot study). Br J Surg 2019;106:720–728 [DOI] [PubMed] [Google Scholar]
- 20. Karakatsanis A, Olofsson H, Stålberg P, Bergkvist L, Abdsaleh S, Wärnberg F. Simplifying logistics and avoiding the unnecessary in patients with breast cancer undergoing sentinel node biopsy. A prospective feasibility trial of the preoperative injection of super paramagnetic iron oxide nanoparticles. Scand J Surg 2018;107:130–137 [DOI] [PubMed] [Google Scholar]
- 21. Karakatsanis A, Daskalakis K, Stålberg P, Olofsson H, Andersson Y, Eriksson Set al. . Superparamagnetic iron oxide nanoparticles as the sole method for sentinel node biopsy detection in patients with breast cancer. Br J Surg 2017;104:1675–1685 [DOI] [PubMed] [Google Scholar]
- 22. Zacharioudakis K, Down S, Bholah Z, Lee S, Khan T, Maxwell AJet al. . Is the future magnetic? Magseed localisation for non palpable breast cancer. A multi-centre non randomised control study. Eur J Surg Oncol 2019; 45:2016–2021 [DOI] [PubMed] [Google Scholar]
- 23. Micha AE, Sinnett V, Downey K, Allen S, Bishop B, Hector LRet al. . Patient and clinician satisfaction and clinical outcomes of magseed compared with wire-guided localisation for impalpable breast lesions. Breast Cancer 2021;28:196–205 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 24. Hersi AF, Eriksson S, Ramos J, Abdsaleh S, Wärnberg F, Karakatsanis A. A combined, totally magnetic technique with a magnetic marker for non-palpable tumour localization and superparamagnetic iron oxide nanoparticles for sentinel lymph node detection in breast cancer surgery. Eur J Surg Oncol 2019;45:544–549 [DOI] [PubMed] [Google Scholar]
- 25. Guyatt GH, Oxman AD, Vist GE, Kunz R, Falck-Ytter Y, Alonso-Coello Pet al. . GRADE: an emerging consensus on rating quality of evidence and strength of recommendations. BMJ 2008;336:924–926 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 26. Page MJ, McKenzie JE, Bossuyt PM, Boutron I, Hoffmann TC, Mulrow CDet al. . The PRISMA 2020 statement: an updated guideline for reporting systematic reviews. BMJ 2021;372:n71. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 27. DerSimonian R, Laird N. Meta-analysis in clinical trials. Control Clin Trials 1986;7:177–188 [DOI] [PubMed] [Google Scholar]
- 28. Borenstein M, Higgins JPT, Hedges LV, Rothstein HR. Basics of meta-analysis: I2 is not an absolute measure of heterogeneity. Res Synth Methods 2017;8:5–18 [DOI] [PubMed] [Google Scholar]
- 29. Egger M, Davey Smith G, Schneider M, Minder C. Bias in meta-analysis detected by a simple, graphical test. BMJ 1997;315:629–634 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 30. Nyaga VN, Arbyn M, Aerts M. Metaprop: a stata command to perform meta-analysis of binomial data. Arch Public Health 2014;72:39. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 31. Harbord RM, Higgins JPT. Meta-regression in Stata. Stata J. 2008;8:493–519 [Google Scholar]
- 32. Sterne JA, Hernán MA, Reeves BC, Savović J, Berkman ND, Viswanathan Met al. . ROBINS-I: a tool for assessing risk of bias in non-randomised studies of interventions. BMJ 2016;355:i4919. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 33. Slim K, Nini E, Forestier D, Kwiatkowski F, Panis Y, Chipponi J. Methodological index for non-randomized studies (minors): development and validation of a new instrument. ANZ J Surg 2003;73:712–716 [DOI] [PubMed] [Google Scholar]
- 34. Wells GA, Shea BJ, O’Connell D, Peterson J, Welch V, Losos Met al. . The Newcastle–Ottawa Scale (NOS) for assessing the quality of nonrandomised studies in meta-analyses. Appl Eng Agric 2014;18:727–734. [Google Scholar]
- 35. Whiting PF, Rutjes AWS, Westwood ME, Mallett S, Deeks JJ, Reitsma JBet al. . QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies. Ann Intern Med 2011;155:529–536 [DOI] [PubMed] [Google Scholar]
- 36. Rubio IT, Diaz-Botero S, Esgueva AJ, Espinosa-Bravo M. Increased detection of sentinel nodes in breast cancer patients with the use of superparamagnetic iron oxide tracer. J Clin Oncol 2014;32:100 [Google Scholar]
- 37. Ahmed M, Anninga B, Goyal S, Young P, Pankhurst QA, Douek M. Magnetic sentinel node and occult lesion localization in breast cancer (MagSNOLL trial). Br J Surg 2015;102:646–652 [DOI] [PubMed] [Google Scholar]
- 38. Taruno K, Kurita T, Kuwahata A, Yanagihara K, Enokido K, Katayose Yet al. . Multicenter clinical trial on sentinel lymph node biopsy using superparamagnetic iron oxide nanoparticles and a novel handheld magnetic probe. J Surg Oncol 2019;120:1391–1396 [DOI] [PubMed] [Google Scholar]
- 39. Hamzah JL, Tan BKT, Tan V, Madhukumar P, Lim SZ, Sim YRet al. . A pilot study comparing Sentimag/Sienna versus standard modality for sentinel lymph node identification in patients with breast cancer. Breast J 2020;26:1074–1077 [DOI] [PubMed] [Google Scholar]
- 40. Giménez-Climent J, Marín-Hernández C, Fuster-Diana CA, Torró-Richart JA, Navarro-Cecilia J. Sentinel lymph node biopsy in breast cancer after neoadjuvant therapy using a magnetic tracer versus standard technique: a multicentre comparative non-inferiority study (IMAGINE-II). Int J Surg Open 2021;35:100404 [Google Scholar]
- 41. Wärnberg F, Stigberg E, Obondo C, Olofsson H, Abdsaleh S, Wärnberg Met al. . Long-term outcome after retro-areolar versus peri-tumoral injection of superparamagnetic iron oxide nanoparticles (SPIO) for sentinel lymph node detection in breast cancer surgery. Ann Surg Oncol 2019;26:1247–1253 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 42. Makita M, Manabe E, Kurita T, Takei H, Nakamura S, Kuwahata Aet al. . Moving a neodymium magnet promotes the migration of a magnetic tracer and increases the monitoring counts on the skin surface of sentinel lymph nodes in breast cancer. BMC Med Imaging 2020;20:58. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 43. Lorek A, Stojčev Z, Zarębski W, Kowalczyk M, Szyluk K. Analysis of postoperative complications after 303 sentinel lymph node identification procedures using the SentiMag® method in breast cancer patients. Med Sci Monit 2019;25:3154–3160 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 44. Man V, Wong TT, Co M, Suen D, Kwong A. Sentinel lymph node biopsy in early breast cancer: magnetic tracer as the only localizing agent. World J Surg 2019;43:1991–1996 [DOI] [PubMed] [Google Scholar]
- 45. Vural V, Yılmaz OC. The Turkish SentiMAG feasibility trial: preliminary results. Breast Cancer; 2020;27:261–265 [DOI] [PubMed] [Google Scholar]
- 46. Bazire L, Alran S, El Bamrani S, Gaujal L, Vincent-Salomon A, Tardivon Aet al. . Radiation therapy after sentinel lymph node biopsy for early stage breast cancer using a magnetic tracer: results of a single institutional prospective study of tolerance. Cancer Radiother 2019;23:23–27 [DOI] [PubMed] [Google Scholar]
- 47. Pohlodek K, Sečanský P, Haluzová I, Mečiarová I. Localization of impalpable breast lesions and detection of sentinel lymph nodes through magnetic methods. Eur J Radiol 2019;120:108699. [DOI] [PubMed] [Google Scholar]
- 48. Kurylcio A, Pelc Z, Skórzewska M, Rawicz-Pruszyński K, Mlak R, Gęca Ket al. . Superparamagnetic iron oxide for identifying sentinel lymph node in breast cancer after neoadjuvant chemotherapy: feasibility study. J Clin Med 2021;10:3149. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 49. Shams S, Lippold K, Blohmer JU, Röhle R, Kühn F, Karsten MM. A pilot study evaluating the effects of Magtrace® for sentinel node biopsy in breast cancer patients regarding care process optimization, reimbursement, surgical time, and patient comfort compared with standard Technetium99. Ann Surg Oncol 2021;28:3232–3240 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 50. ISRCTN Registry . Postoperative Breast MRI in Patients Undergoing Sentinel Node Biopsy Using Super Paramagnetic Iron Oxide Nanoparticles. https://www.isrctn.com/ISRCTN85167182 (accessed 26 June 2022)
- 51. Teshome M, Wei C, Hunt KK, Thompson A, Rodriguez K, Mittendorf EA. Use of a magnetic tracer for sentinel lymph node detection in early-stage breast cancer patients: a meta-analysis. Ann Surg Oncol 2016;23:1508–1514 [DOI] [PubMed] [Google Scholar]
- 52. Peek MCL, Saeki K, Ohashi K, Chikaki S, Baker R, Nakagawa Tet al. . Optimization of SPIO injection for sentinel lymph node dissection in a rat model. Cancers (Basel) 2021;13 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 53. Jazrawi A, Pantiora E, Abdsaleh S, Bacovia DV, Eriksson S, Leonhardt Het al. . Magnetic-guided axillary ultrasound (MagUS) sentinel lymph node biopsy and mapping in patients with early breast cancer. a phase 2, single-arm prospective clinical trial. Cancers (Basel) 2021;13 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 54. Mok CW, Tan SM, Zheng Q, Shi L. Network meta-analysis of novel and conventional sentinel lymph node biopsy techniques in breast cancer. BJS Open 2019;3:445–452 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 55. McGuinness LA, Higgins JPT. Risk-of-bias VISualization (robvis): an R package and Shiny web app for visualizing risk-of-bias assessments. Res Synth Methods 2021;12:55–61 [DOI] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Supplementary Materials
Data Availability Statement
The review protocol, template data collection forms, data extracted from included studies, and data used for all analyses can be accessed upon reasonable request.