Skip to main content
Acta Cirúrgica Brasileira logoLink to Acta Cirúrgica Brasileira
. 2023 Aug 28;38:e383023. doi: 10.1590/acb383023

A realistic model for vasectomy reversal training using swine testicles

Deivid Ramos dos Santos 1, Wender de Jesus Pena Corrêa Junior 2, Lívia Guerreiro de Barros Bentes 1,*, Rafael Silva Lemos 1, Victor Matheus Mendonça de Araújo 1, Gabrielly Leite Andrade 3, Renan Kleber Costa Teixeira 1, Luís Otávio Amaral Duarte Pinto 1, Herick Pampolha Huet de Bacelar 4
PMCID: PMC10470310  PMID: 37646762

ABSTRACT

Purpose:

To evaluate the viability of the porcine vas deferens as a realistic microsurgical training model for vasectomy reversal

Methods:

The model uses swine testicles (vas deferent), which are usually discarded in large street markets since they are not part of Brazilian cuisine. The spermatic cord was carefully dissected, and the vas deferens were isolated, measuring 10 cm in length. A paper quadrilateral with 5 cm2 was built to delimit the surgical training field. The objective of the model is to simulate only the microsurgical step when the vas deferens are already isolated. The parameters analyzed were: feasibility for reproducing the technique, patency before and after performing the vasovasostomy, cost of the model, ease of acquisition, ease of handling, execution time, and model reproducibility.

Results:

The simulator presented low cost. All models made were viable with a texture similar to human, with positive patency obtained in 100% of the procedures. The internal and external diameters of the vas deferens varied between 0.2-0.4 mm and 2-3 mm, respectively, with a mean length of 9 ± 1.2 cm. The total procedure time was 43.28 ± 3.22 minutes.

Conclusions:

The realistic model presented proved to be viable for carrying out vasectomy reversal training, due to its low cost, easy acquisition, and easy handling, and providing similar tissue characteristics to humans.

Key words: Vasovasostomy, Microsurgery, Urologic Surgical Procedures, Low Cost Technology, Simulation Training

Introduction

Vasectomy is a safe and relatively simple male sterilization surgical procedure whose efficiency has made it one of the most popular contraceptive methods worldwide1,2. It is estimated that around 60 million men performed it3. However, the death of a child, early age, divorce, and new relationships are reasons to regain male fertility4,5. From this, numerous techniques were developed to recover fertility, such as percutaneous epididymal sperm aspiration and testicular sperm aspiration, both associated with in-vitro fertilization or intracytoplasmic sperm injection6-8.

However, due to its superior cost-benefit ratio compared to the other ones, vasectomy reversal has become the most preferred fertilization method for vasectomized men5-8. This procedure can be performed in two different ways: vasovasostomy or vasoepididymostomy, both technically evolving over the years to improve post-surgical results5,6. However, unlike vasectomy, its reversal is a microsurgical procedure that depends on good clinical judgment, its feasibility, and, mainly, technically qualified professionals for its execution6,7.

In addition, due to its high level of complexity, this technique becomes extremely challenging for the less experienced urologist, since it demands years of training in microsurgery, which, until recently, were performed directly on human beings, increasing the risk of damage and complications5. In this sense, the use of training models constitutes a crucial step in the development and improvement of microsurgical skills, before performing any procedure in humans6,9,10.

There are different types of microsurgical simulators for training: synthetic ones, for example, are widely used in initial learning, but they are generally expensive, do not faithfully portray tissue characteristics, and are only present in large reference centers9-11; in-vivo simulators, in turn, provide realistic characteristics to the surgical procedure, but depend on the approval of an ethics committee for the use of animals, whose tendency is to increasingly restrict the use of animals for practical training11.

Thus, the search for models for realistic training and high fidelity to surgical practice, without disrespecting the current ethical norms or restricting the gain of technical skills, is being sought12,13. Based on this, the present study aimed to evaluate the feasibility of a discard animal model for training in vasectomy reversal.

Methods

It was an experimental and cross-sectional study carried out at the Laboratory of Experimental Surgery at the Universidade do Estado do Pará, following the Brazilian laws on the use and creation of animals (Law No. 11.794/08), obtaining the opinion of a waiver by the Committee of Ethics in the Use of Animals, since the product used in this study is discarded in large street markets because it is not part of the diet of the local population.

Testicles and spermatic cords were obtained after mandatory castration of pigs for meat marketing (Decree No. 9013 of March 29, 2017, Article 104) at a local breeding facility. The material was stored under refrigeration (5°C) and placed at room temperature (26°C) 1 hour before the procedure.

The performance of the microsurgical technique followed the guidelines proposed by the literature13-15 using a video system composed of a Sony Handycam HDR-XR160 high-definition (HD) camera, with 40x zoom, a 42-inch LED HD television and a digital HDMI cable, in addition to common lighting fixtures adapted to the camera providing adequate lighting for the procedure.

The present simulator only allows the execution of the anastomosis and not the complete surgery, without anesthesia, incision in planes, and hemostasis. Therefore, the creation of the training model followed the steps described ahead. First, with the aid of latex gloves, a cardboard, a stapler and common scissors, quadrilaterals measuring 5 cm × 5 cm were made with two holes on opposite sides, one for entry and one for exit10,16. Then, the testis and the spermatic cord were washed with running water and soap to remove impurities.

Subsequently, the funiculus was completely dissected, from its origin to the proximal stump, where it ruptured during castration of the pig, and the vas deferens were isolated in the quadrilateral. After that, a total cross-section of the canal was performed with the aid of curved Metzenbaum scissors.

The reversal technique chosen was vasovasostomy, characterized by eight equidistant simple stitches (four at 3, 6, 9 and 12 o’clock and four interspersed), made with 10-0 nylon thread, coapting the entire circumference, without affecting the lumen17. The instruments used to perform the technique were: watchmaker’s tweezers, a needle holder and curved microsurgical scissors. Patency was tested with the introduction of a 24G Jelco, with a slow injection of 5 to 10 mL of 0.9% saline solution (SF 0.9%), or a 2-0 Prolene thread, replacing the Jelco, when the injection liquid did not flow properly Figs. 1 and 2).

Figure 1. Microsurgical steps of the training model. (a) Swine testicle after washing and thawing. (b) Duct deferens dissected and removed from the testis. (c) Deferent duct transversely sectioned. (d) Performing the first transfixation in the duct with 10-0 nylon thread. (e) Deferent duct transfixed with 10-0 nylon threads. (f) Completely sutured vas deferens.

Figure 1

Source: elaborated by the authors.

Figure 2. Sutured vas deferens submitted to the patency test.

Figure 2

Source: elaborated by the authors.

In all, five models were created, and all procedures were performed by only one researcher, with more than 10 years of experience in the area, to avoid bias in the research. The parameters analyzed were: feasibility for reproducing the technique, patency before and after performing the vasovasostomy, cost of the model, ease of acquisition, ease of handling, execution time and model reproducibility. Microsoft Word 2016 and Excel 2016 software were used for data analysis and image editing.

Results

All models made proved to be viable for carrying out vasectomy reversal training, with positive patency obtained in 100% of them. The materials used were easy to acquire and had no cost. The human-like consistency of the vas deferens provided adequate handling during the procedure.

The luminal diameter and external diameter of the vas deferens varied between 0.2-0.4 and 2-3 mm, respectively, with a mean length of 9 ± 1.2 cm. It was possible to perform the technique up to three times on each model. Vas deferens shorter than 6 cm were discarded, since they tend to disconnect from the quadrilateral exit orifice, making the technique difficult.

The mean total procedure time was 43.28 ± 3.22 minutes. Local humidification with jets of 0.5 mL of 0.9% SF, with the aid of a 10-mL syringe, was necessary during the execution of the technique. This resulted in an increase of 2.86 ± 0.24 minutes in the total procedure time, given that the mean interval for humidification was 3.00 ± 0.46 minutes.

Discussion

Vasectomy reversal is a microsurgical procedure that consists of the anastomosis of the vas deferens–vasovasostomy–or the vas deferens and the epididymis–vasoepididymostomy–, to restore fertility as a result of a previous vasectomy5,6,8.

Despite their high efficiency, most high-fidelity simulators require high-cost technologies for their manufacture, such as three-dimensional models6,10,18. This restricts the use of these technologies to large training centers. On the other hand, the present model did not present costs, since the components–swine testicle and spermatic cord–are commonly discarded by the breeding sites, allowing the training to be carried out anywhere.

The five models made allowed their reuse up to three times each, with 15 procedures being performed in total, obtaining positive patency in 100% of the attempts. There was impairment in the quality of the procedure with a greater number of attempts, due to tissue wear with frequent handling. This fact suggests the considerable evolution of skills that the model can offer, due to the number of repetitions provided by it, although they are limited5,6,9,10,12,15,19. The average time of each procedure (43.28 ± 3.22 minutes) was similar to that one found10, with 6.6% of this time being allocated to humidifying the duct due to high adherence to latex due to dehydration, and, although time is an important evaluation variable, the quality of the technique is paramount19.

According to Patel and Smith5, the human vas deferens has a luminal diameter that can vary from 0.3 to 0.4 mm and the epididymal from 0.15 to 0.2 mm. Vasoepididymostomy technique is more challenging than vasovasostomy for most surgeons, making the latter the most performed. This makes clear why the latter technique was used in the model, as the most complex one must be performed after a considerable level of learning20. In addition, the vas deferens presented tissue consistency similar to that of humans, and the luminal duct had a variable diameter of 0.2-0.4 mm, increasing the fidelity of the model to reality.

It is worth noticing that the present study had limitations. Avulsion of the spermatic cord during castration18 can reduce the internal diameter of the vas deferens, making it impossible to perform the patency test, in addition to reducing the length of the vessel to an unviable size for use in the model (< 6 cm). In addition, the use of video magnification systems, despite reducing the risks of contamination, as well as the costs compared to a conventional microscope, limits the initial stages of training because they do not present three dimensions, which can be circumvented after a previous period of adaptation13,20. Even so, the model offers high fidelity to urological practice, becoming an ally in the acquisition of microsurgical skills.

Conclusion

It was concluded that the porcine vas deferens proved to be viable for carrying out vasectomy reversal training, since the dimensions of its walls and consistency are similar to human ones, obtaining positive patency in the five models tested. In addition, the easy acquisition, low cost, absence of special conditions for use, respect for ethical principles of reducing the unnecessary use of animals, and reproducibility in several training centers make this model attractive.

Acknowledgments

Not applicable.

Footnotes

Research performed at the Laboratory of Experimental Surgery, Universidade do Estado do Pará – (Belém) Pará – Brazil.

Funding: Not applicable.

Data availability statement.

The data will be available upon request.

References

  • 1.Santos DR, Mangabeira JVC, Silva MVA, José BMPA, Valente MA, Dias PS, Gomes CBS, Silva AFT, Pinto LOD, Barros CAV. Crescimento da vasectomia no Sistema Único de Saúde entre 2009 a 2018: um estudo retrospectivo. Rev Eletrôn Acervo Saúde. 2020;12(3):e2822. doi: 10.25248/reas.e2822.2020. [DOI] [Google Scholar]
  • 2.Greek G. Vasectomy. A safe, effective, economical means of sterilization. Postgrad Med. 2000;108(2):173–179. doi: 10.3810/pgm.2000.08.1189. [DOI] [PubMed] [Google Scholar]
  • 3.Eisenberg ML, Lipshultz LI. Re: Estimating the number of vasectomies performed annually in the United States: data from the national survey of family growth. J Urol. 2011;185(4):1541–1542. doi: 10.1016/j.juro.2010.11.058. [DOI] [PubMed] [Google Scholar]
  • 4.Sharma V, Le BV, Sheth KR, Zagaroff S, Dupree JM, Cashy J, Brannigan RE. Vasectomy demographics and postvasectomy desire for future children: results from a contemporary national survey. Fertil Steril. 2013;99(7):1880–1885. doi: 10.1016/j.fertnstert.2013.02.032. [DOI] [PubMed] [Google Scholar]
  • 5.Patel AP, Smith RP. Vasectomy reversal: a clinical update. Asian J Androl. 2016;18(3):365–371. doi: 10.4103/1008-682X.175091. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 6.Hayden RP, Li PS, Goldstein M. Microsurgical vasectomy reversal: contemporary techniques, intraoperative decision making, and surgical training for the next generation. Fertil Steril. 2019;111(3):444–453. doi: 10.1016/j.fertnstert.2019.01.004. [DOI] [PubMed] [Google Scholar]
  • 7.Kavoussi PK, Kavoussi KM, Odenwald KC, Kavoussi SK. Factors impacting couples’ decision-making between vasectomy reversal versus sperm retrieval/in vitro fertilization/intracytoplasmic sperm injection. Andrology. 2018;6(4):556–558. doi: 10.1111/andr.12491. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 8.Esteves SC, Miyaoka R, Agarwal A. Sperm retrieval techniques for assisted reproduction. Int Braz J Urol. 2011;37(5):570–683. doi: 10.1590/s1677-55382011000500002. [DOI] [PubMed] [Google Scholar]
  • 9.Martins PN, Montero EF. Basic microsurgery training: comments and proposal. Acta Cir Bras. 2007;22(1):79–81. doi: 10.1590/s0102-86502007000100014. [DOI] [PubMed] [Google Scholar]
  • 10.Pinto LOAD, Barros CAV, Lima AB, Santos DR, Bacelar HPH. Portable model for vasectomy reversal training. Int Braz J Urol. 2019;45(5):1013–1019. doi: 10.1590/S1677-5538.IBJU.2019.0092. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 11.Hwang G, Oh CW, Park SQ, Sheen SH, Bang JS, Kang HS. Comparison of different microanastomosis training models: model accuracy and practicality. J Korean Neurosurg Soc. 2010;47(4):287–290. doi: 10.3340/jkns.2010.47.4.287. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 12.Santos DRD, Calvo FC, Feijó DH, Araújo NP, Teixeira RKC, Yasojima EY. New training model using chickens intestine for pediatric intestinal anastomosis. Acta Cir Bras. 2019;34(7):e201900709. doi: 10.1590/s0102-865020190070000009. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 13.Sergio R, Barros M, Brito MV, Leal RA, Teixeira RKC, Sabbá MF, Yamani VN, Lemos MVV. An low-cost high-definition video system for microsurgical hindlimb replantation in rats. J Reconstr Microsurg. 2017;33(3):158–162. doi: 10.1055/s-0036-1593767. [DOI] [PubMed] [Google Scholar]
  • 14.Monteiro de Barros RS, Brito MVH, Teixeira RKC, Yamaki VN, Costa FLS, Sabbá MF, Lemos MVV, Paraense IG, Feijó DH. High-definition video system for peripheral neurorrhaphy in rats. Surg Innov. 2017;24(4):369–372. doi: 10.1177/1553350617704755. [DOI] [PubMed] [Google Scholar]
  • 15.Barros RSM, Santos DR, Teixeira RKC, Araújo NP, Somensi DN, Candido AA. Anatomorphometry of the brachial plexus under high-definition system: an experimental study in rats. Acta Cir Bras. 2022;37(2):e370206. doi: 10.1590/acb370206. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 16.Javid P, Aydın A, Mohanna PN, Dasgupta P, Ahmed K. Current status of simulation and training models in microsurgery: A systematic review. Microsurgery. 2019;39(7):655–668. doi: 10.1002/micr.30513. [DOI] [PubMed] [Google Scholar]
  • 17.Ramada Benlloch FJ, de la Torre Abril, Tramoyeres Galvañ, Canovas Ivorra, Sánchez Ballester, Ordoño Domínguez, Navalón Verdejo, Zaragoza Orts. Nuestra experiencia en vasovasostomia simplificada. Revisión de los resultados obtenidos en los ultimos 5 años [Our experience with simplified vasovasostomy. Review of our results during the last 5 years] Arch Esp Urol. 2004;57(1):59–63. [PubMed] [Google Scholar]
  • 18.Rault J-L, Lay DC, Marchant-Forde JN. Castration induced pain in pigs and other livestock. Appl Anim Behav Sci. 2011;135(3):214–225. doi: 10.1016/j.applanim.2011.10.017. [DOI] [Google Scholar]
  • 19.Starkes JL, Payk I, Hodges NJ. Developing a standardized test for the assessment of suturing skill in novice microsurgeons. Microsurgery. 1998;18(1):19–22. doi: 10.1002/(sici)1098-2752(1998)18:1<19::aid-micr5>3.0.co;2-p. [DOI] [PubMed] [Google Scholar]
  • 20.Han JJ, Patrick WL. See one-practice-do one-practice-teach one-practice: The importance of practicing outside of the operating room in surgical training. J Thorac Cardiovasc Surg. 2019;157(2):671–677. doi: 10.1016/j.jtcvs.2018.07.108. [DOI] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Data Availability Statement

The data will be available upon request.


Articles from Acta Cirúrgica Brasileira are provided here courtesy of Sociedade Brasileira para Desenvolvimento Pesquisa em Cirurgia

RESOURCES