Skip to main content
British Heart Journal logoLink to British Heart Journal
. 1989 Oct;62(4):284–290. doi: 10.1136/hrt.62.4.284

Doppler flow characteristics in the assessment of pulmonary artery pressure in ductus arteriosus.

A B Houston 1, M K Lim 1, W B Doig 1, J Gnanapragasam 1, E N Coleman 1, M P Jamieson 1, J C Pollock 1
PMCID: PMC1277365  PMID: 2803875

Abstract

The Doppler spectral pattern of flow through the ductus arteriosus was studied in 117 patients. In 37 who underwent catheterisation, Doppler records and aortic and pulmonary artery pressure were available (21 simultaneously with two catheters) for review while the others had surgical ligation of the duct on the basis of the results of non-invasive tests. Four flow patterns were obtained: (a) continuous flow, maximum velocity in late systole with gradual fall throughout diastole; (b) continuous flow, high systolic flow with rapid fall to a very low early diastolic velocity maintained throughout diastole; (c) continuous low velocity, maximum in late diastole; and (d) bidirectional flow. Flow pattern (a) was associated with normal or slightly raised pulmonary artery pressure; (b) with raised pulmonary artery pressure; and (c) and (d) with pulmonary artery pressure at systemic values. Comparison of the Doppler and measured pressure differences between the great arteries was reasonably good for peak values but poor for the trough readings. Doppler ultrasound clearly showed ductal flow; the flow pattern gave an indication of the pulmonary artery pressure, but pressure measurement by application of the Bernoulli equation to the flow velocities cannot yet be regarded as reliable.

Full text

PDF
290

Images in this article

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Bland J. M., Altman D. G. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986 Feb 8;1(8476):307–310. [PubMed] [Google Scholar]
  2. Hatle L., Brubakk A., Tromsdal A., Angelsen B. Noninvasive assessment of pressure drop in mitral stenosis by Doppler ultrasound. Br Heart J. 1978 Feb;40(2):131–140. doi: 10.1136/hrt.40.2.131. [DOI] [PMC free article] [PubMed] [Google Scholar]
  3. Hiraishi S., Horiguchi Y., Misawa H., Oguchi K., Kadoi N., Fujino N., Yashiro K. Noninvasive Doppler echocardiographic evaluation of shunt flow dynamics of the ductus arteriosus. Circulation. 1987 Jun;75(6):1146–1153. doi: 10.1161/01.cir.75.6.1146. [DOI] [PubMed] [Google Scholar]
  4. Musewe N. N., Smallhorn J. F., Benson L. N., Burrows P. E., Freedom R. M. Validation of Doppler-derived pulmonary arterial pressure in patients with ductus arteriosus under different hemodynamic states. Circulation. 1987 Nov;76(5):1081–1091. doi: 10.1161/01.cir.76.5.1081. [DOI] [PubMed] [Google Scholar]
  5. RUDOLPH A. M., MAYER F. E., NADAS A. S., GROSS R. E. A clinical and hemodynamic study of 23 patients in the first year of life. Pediatrics. 1958 Nov;22(5):892–904. [PubMed] [Google Scholar]
  6. Spach M. S., Serwer G. A., Anderson P. A., Canent R. V., Jr, Levin A. R. Pulsatile aortopulmonary pressure-flow dynamics of patent ductus arteriosus in patients with various hemodynamic states. Circulation. 1980 Jan;61(1):110–122. doi: 10.1161/01.cir.61.1.110. [DOI] [PubMed] [Google Scholar]
  7. Stevenson J. G., Kawabori I., Guntheroth W. G. Noninvasive detection of pulmonary hypertension in patent ductus arteriosus by pulsed Doppler echocardiography. Circulation. 1979 Aug;60(2):355–359. doi: 10.1161/01.cir.60.2.355. [DOI] [PubMed] [Google Scholar]
  8. Stevenson J. G., Kawabori I., Guntheroth W. G. Pulsed Doppler echocardiographic diagnosis of patent ductus arteriosus: sensitivity, specificity, limitations, and technical features. Cathet Cardiovasc Diagn. 1980;6(3):255–263. doi: 10.1002/ccd.1810060306. [DOI] [PubMed] [Google Scholar]
  9. Swensson R. E., Valdes-Cruz L. M., Sahn D. J., Sherman F. S., Chung K. J., Scagnelli S., Hagen-Ansert S. Real-time Doppler color flow mapping for detection of patent ductus arteriosus. J Am Coll Cardiol. 1986 Nov;8(5):1105–1112. doi: 10.1016/s0735-1097(86)80388-6. [DOI] [PubMed] [Google Scholar]
  10. Wilson N., Dickinson D. F., Goldberg S. J., Scott O. Pulmonary artery velocity patterns in ductus arteriosus. Br Heart J. 1984 Oct;52(4):462–464. doi: 10.1136/hrt.52.4.462. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from British Heart Journal are provided here courtesy of BMJ Publishing Group

RESOURCES