Skip to main content
European Heart Journal Open logoLink to European Heart Journal Open
. 2026 Jan 21;6(1):oeag008. doi: 10.1093/ehjopen/oeag008

Extraction and reimplantation of cardiac implantable electronic devices in patients with non-surgically treated infective endocarditis: a nationwide cohort study

Mohammed Bakir Ahmad Lafta 1,✉,2, Amna Alhakak 2, Lauge Østergaard 3, Niels Eske Bruun 4,5, Anne-Christine Ruwald 6,7, Melanie Vuong Le 8, Berit Philbert 9, Michael Vinther 10, Peter Godsk Jørgensen 11, Eva Havers-Borgersen 12,13, Louise Kruse Jensen 14, Jonas Agerlund Povlsen 15, Jens Cosedis Nielsen 16,17, Jens Brock Johansen 18, Marianne Voldstedlund 19, Claus Moser 20,21, Henning Bundgaard 22,23, Lars Køber 24,25, Emil Fosbøl 26,27
Editor: Frieder Braunschweig
PMCID: PMC12930842  PMID: 41743286

Abstract

Aims

Cardiac implantable electronic device (CIED)-related infective endocarditis (IE) is associated with morbidity and mortality. Current guidelines recommend complete CIED extraction; however, the optimal timing for reimplantation remains uncertain. We aimed to evaluate CIED reimplantation rates, and outcomes in patients with non-surgically treated IE who underwent CIED extraction.

Methods and results

We included all Danish residents ≥18 years diagnosed with first-time IE (2010–2021), with a pre-existing CIED, who underwent CIED extraction without concurrent valve surgery. Data were obtained from Danish nationwide registries. The primary variable of interest was CIED reimplantation within 90 days after extraction. Reimplantation rates were described, and reimplantation status was used to stratify patients for analysis of secondary outcomes, including recurrent IE-related bacteraemia and all-cause mortality within 6 months. Among 661 patients with CIED extraction due to IE, 396 (59.9%) underwent reimplantation within 3 months, with a median of 29 days (IQR:19–42 days). There was no significant difference in the 6 month cumulative incidence of recurrent bacteraemia with IE (2.5% [95% CI:0.95–5.5] vs. 1.8% [95% CI:0.8–3.6] P = 0.55) or mortality (11.2% [95% CI:7.0–16.4] vs. 7.0% [95% CI:4.7–10.0]; P = 0.11) between non-reimplanted and reimplanted patients.

Conclusion

In IE patients who underwent CIED extraction, 60% of patients were reimplanted within 3 months with substantial variation in timing. No significant differences in outcomes were found by reimplantation status.

Keywords: Cardiac implantable electronic device, Pacemaker, Implantable cardioverter–defibrillator, Infective endocarditis, Reimplantation, Outcomes

Graphical Abstract

Graphical Abstract.

Graphical Abstract

Introduction

The increasing number of cardiac implantable electronic device (CIED) implantations over the years has been paralleled by a rising incidence of CIED-related infective endocarditis (CIED–IE).1 This condition is associated with significant mortality, morbidity, severe complications, increased hospitalizations, and higher healthcare costs.2,3 The rising incidence of CIED-related IE may be driven by an ageing population, broader device indications, and the growing procedural complexity of implanting multiple leads and performing generator replacements.4–6 Although these complicating factors exist, it is important to acknowledge that CIEDs have significantly improved the treatment and prognosis of many cardiac conditions.2,4,7

According to current guidelines, the optimal management of CIED infections, whether classified as definite or possible, often involves complete CIED extraction, combined with extended antibiotic treatment.2,8 However, some patients continue to require CIED support, making the timing of reimplantation a critical consideration. As of now, precise recommendations on the timing of reimplantation following infection-related device extraction is lacking. Multiple factors influence this decision, including pacing indication, lead dwell time, the type and severity of infection, inflammatory marker levels, and the patient’s clinical response to treatment.9

In view of the rising incidence10 and serious consequences of CIED-related IE, understanding reimplantation patterns and associated outcomes is essential. Therefore, this study aimed to evaluate reimplantation rates and reimplantation timing among patients with non-surgically treated IE who underwent CIED extraction. Additionally, we set out to investigate the factors associated with reimplantation, as well as associated outcomes, including recurrent bacteraemia with and without IE, IE readmission, and all-cause mortality, stratified by reimplantation status.

Methods

Data source

Every citizen in Denmark is assigned a unique and permanent civil registration number making it possible to link nationwide administrative registries. In this nationwide study, we collected data from the Danish National Patient Registry (DNPR),11 the Danish National Prescription Registry,12 the Danish population registry,13 and the Danish Microbiology Database.14 The DNPR registry contains information on every hospital admission and outpatient contact since 1977, with diagnoses coded by physicians. Until 1994, diagnostic coding followed the International Classification of Diseases, Eighth Revision (ICD-8), transitioning thereafter to the Tenth Revision (ICD-10). The DNPR also provides data on surgical procedures based on the Nordic Medico-Statistical Committee Classification of Surgical Procedures (NCSP). The Danish Microbiology Database provides data from all Danish departments of clinical microbiology since 2010. The Danish National Prescription Registry contains data on all filled prescriptions at Danish pharmacies, classified according to Anatomical Therapeutic Chemical (ATC) codes. Demographic variables such as sex, date of birth, date of death, and migration status were provided from the Danish Civil Registration System. All four registries are validated and of high quality.11–14

Study population

The main study population included all Danish residents aged ≥18 years who were hospitalized with first-time IE from 1 January 2010 to 31 December 2021 and who were non-surgically treated, defined as no heart valve surgery during IE admission (see Supplementary material online, Table S1 for NCSP codes of heart valve surgery). Patients with IE were identified based on inpatient primary or secondary diagnoses using the following ICD-10 codes: acute endocarditis (DI339), acute or subacute IE (DI330), endocarditis, unspecified, in diseases classified elsewhere (DI398), and endocarditis unspecified (DI38). The accuracy of the IE diagnosis in the DNPR has been previously validated with a high positive predictive value (PPV) of 90% for admission ≥14 days, based on the ICD-10 codes.15,16 Therefore, we included patients who were hospitalized for ≥14 days or those who died within 14 days during IE admission.

Only patients with a pre-existing CIED [i.e. pacemakers (PM), implantable cardioverter defibrillators (ICD), and cardiac resynchronization therapy with or without defibrillator (CRT-D or CRT-P)] who underwent CIED extraction during their IE admission were included in the study cohort. We included data on the most recent CIED procedure from the DNPR, recorded at any time prior to IE admission (see Supplementary material online, Table S2 for NCSP codes of CIED procedures and CIED extraction). The PPVs for the procedure codes of CIEDs in the DNPR have been validated with a high PPV of 100%.17

We used the Danish Microbiology Database to identify a possible microbiological cause of IE for the included patients. If multiple blood culture results were available, a bacterial hierarchy was performed based on the relevance to IE: (i) highest priority included Staphylococcus aureus, Enterococcus species, Streptococcus species, and HACEK group organisms [Haemophilus species (not including Haemophilus influenzae), Aggregatibacter species, Cardiobacterium species, Eikenella species, Kingella species]; (ii) intermediate priority included coagulase-negative staphylococci (CoNS); (iii) low priority covered other bacterial findings such as rare bacteria and bacteria not identified at the species level; and (iv) lowest priority was assigned to blood culture-negative results. Due to the low number of HACEK organisms, this group was consequently included in the third category, covering other bacterial findings.

Patient characteristics, comorbidity, and pharmacotherapy

Comorbidities were registered based on inpatient and outpatient diagnoses recorded as primary or secondary diagnoses any time before IE admission, using the ICD-8 and ICD-10 codes (see Supplementary material online, Table S3 for ICD-8 and ICD-10 diagnosis codes). Hypertension was defined, as previously validated, based on redeemed prescriptions for a combination of at least two antihypertensive medications.18 Diabetes was defined, as previously described, based on inpatient or outpatient contacts according to ICD-8 and ICD-10 codes or on redeemed prescriptions for antidiabetic drugs within 6 months prior to IE admission.19,20

Concomitant pharmacotherapy was identified based on ATC codes for redeemed prescriptions within 6 months prior to the IE admission (see Supplementary material online, Table S4 for ATC codes).

Included patients were categorized into frailty groups at the time of IE admission using the previously validated Hospital Frailty Risk Score.21 For every patient, a score was calculated based on data from hospital admissions within 10 years prior to their IE admission. Patients were categorized into three groups based on frailty risk: low (0–4 points), intermediate (5–15 points), and high (>15 points). Patients with a score of ≥5 points were considered as frail.

Diagnoses timely associated with initial CIED implantation were defined within 6 months prior to initial CIED procedure. Secondary prevention was defined as cardiac arrest, ventricular tachycardia (VT), or ventricular fibrillation (VF) within 6 months prior to initial CIED procedure in patients with ICD or CRT-D.

Study outcome

The primary variable of interest was CIED reimplantation within 90 days after extraction (see Supplementary material online, Table S5 for NCSP codes). The secondary outcomes were IE readmission (regardless of microbiological aetiology), IE relapse, recurrent bacteraemia with IE, recurrent bacteraemia without IE (all defined as involving the same microbiological aetiology as the first IE episode), and all-cause mortality within 6 months. All secondary outcomes were analysed stratified by reimplantation status, and recurrent bacteraemia with IE was also stratified by reimplantation timing (≤14 days vs. >14 days). The 14 day cut-off was selected based on clinical rationale, as current guidelines recommend reimplantation only after signs and symptoms of infection have abated and blood cultures have been negative for ≥72 h (or ≥2 weeks in the presence of vegetations).8 The follow-up for the IE-related secondary outcomes began the day after IE discharge, whereas the follow-up for all-cause mortality began 90 days post-extraction. This ensured that all patients had the opportunity for reimplantation, thereby reducing survival bias when comparing reimplanted and non-reimplanted patients. Only patients who survived until IE discharge or 90 days post-extraction were included in the secondary outcome analyses.

Statistics

For comparison of baseline characteristics, the study population was stratified according to CIED reimplantation status. The χ2 test was applied for categorical variables, while the Wilcoxon test was used for continuous variables. Categorical variables are reported as frequencies with percentages, whereas continuous variables are reported as medians with interquartile ranges (IQRs).

The cumulative incidences of CIED reimplantation after the extraction date were calculated using the Aalen–Johansen estimator, accounting for death as competing event. Cause-specific Cox regression analyses were performed to assess factors associated with CIED reimplantation, presented as hazard ratios (HRs) with 95% confidence intervals (CIs). The model was adjusted for sex, age categories (i.e. <70 years, 70–80 years, and >80 years), calendar year of IE admission, time since the most recent CIED procedure, CIED type, diagnoses timely associated with initial CIED implantation such as secondary prevention, second- and third-degree AV block, sick sinus syndrome (SSS), and history of comorbidities such as ischaemic heart disease, atrial fibrillation, stroke, chronic obstructive pulmonary disease (COPD), cancer, diabetes, frailty risk groups, and previous left-sided prosthetic heart valve surgery.

Furthermore, a histogram was created to visualize the time intervals from CIED extraction to reimplantation, while a transition plot was created to illustrate the change in CIED types from before extraction to after reimplantation.

All model assumptions for the cause-specific Cox regression were met, including proportional hazards and no significant interactions between CIED type and other clinically relevant variables.

All statistical analyses were performed with SAS (version 9.4, Cary, NC, USA) on the secure servers of Statistics Denmark. A two-sided P-value < 0.05 was considered statistically significant.

Ethics approval

In Denmark, ethics committee approval is not required for registry-based studies. All personal identifiers were pseudo anonymized, and microdata with observations ≤3 patients were not reported, in accordance with Statistics Denmark’s anonymization guidelines. The study data were provided by Statistics Denmark and approved by the responsible institute, The Capital Region of Denmark (approval number P-2019–191), in accordance with the General Data Protection Regulation.

Results

A total of 6824 patients were diagnosed with first-time IE between 1 January 2010 and 31 December 2021. Of these, 5723 (83.9%) were treated non-surgically (Figure 1), and 1272 (18.6%) of them had a CIED. Among patients with non-surgically managed IE and a CIED, 669 (52.6%) underwent CIED extraction. Eight patients (0.6%) did not have a recorded blood culture and were excluded, leaving 661 patients in the primary study population, corresponding to 52.0% of all patients with a CIED. Among these, 396 (59.9%) received CIED reimplantation, while 265 (40.1%) did not. Within the primary population, 94 patients (14.2%) died within 90 days after extraction. The remaining 567 patients who survived 90 days after extraction comprised the cohort for analyses of all-cause mortality, while 596 patients who survived until IE discharge comprised the population for IE-related outcomes. Among those who survived 90 days post-extraction, 386 (68.1%) received CIED reimplantation, while 181 (31.9%) did not.

Figure 1.

Figure 1

Study population selection. IE, Infective endocarditis; CIED, cardiac implantable electronic device.

Patient characteristics

The baseline characteristics, stratified according to CIED reimplantation status, are summarized in Table 1. The median age of the total study population was 73.7 years ([IQR]: 66.0–79.6), and 520 (78.7%) were males. Patients who underwent CIED reimplantation had similar age compared to those who did not (median age: 73.4 years [IQR: 66.0–79.5] vs. 74.4 years [IQR: 66.0–79.6]) (P = 0.55). The median frailty score was significantly lower in the reimplantation group, with a median frailty score of 5.6 [IQR: 2.1–9.7], compared to 6.3 [IQR: 2.6–11.7] in the non-reimplantation group (P = 0.02). The time from the most recent CIED procedure to IE admission was borderline significantly shorter in reimplanted patients (median: 1.5 years [IQR: 0.3–3.6]) compared to non-reimplanted patients (median: 1.8 years [IQR: 0.4–4.4]) (P = 0.051).

Table 1.

Baseline characteristics according to status of reimplantation

Variable Total (n = 661) No reimplantation (n = 265) Reimplantation (n = 396) P-value
Sex (male) 520 (78.7) 197 (74.3) 323 (81.6) 0.03
Age (median [IQR]) 73.7 [66.0, 79.6] 74.4 [66.0, 79.6] 73.4 [66.0, 79.5] 0.55
Age group
 <70 years 244 (36.9) 96 (36.2) 148 (37.4) 0.93
 70–80 years 267 (40.4) 107 (40.4) 160 (40.4)
 >80 150 (22.7) 62 (23.4) 88 (22.2)
Frailty score group
Low 287 (43.4) 103 (38.9) 184 (46.5) 0.13
Intermediate 287 (43.4) 122 (46.0) 165 (41.7)
Severe 87 (13.2) 40 (15.1) 47 (11.9)
Frailty score (median [IQR]) 6.0 [2.3, 10.4] 6.3 [2.6, 11.7] 5.6 [2.1, 9.7] 0.02
Microbiological aetiology
Staphylococcus aureus 219 (33.1) 96 (36.2) 123 (31.1) 0.23
Enterococcus spp. 85 (12.9) 38 (14.3) 47 (11.9)
 CoNS 65 (9.8) 29 (10.9) 36 (9.1)
Streptococcus spp. 79 (12.0) 29 (10.9) 50 (12.6)
 Negative blood culture 138 (20.9) 44 (16.6) 94 (23.7)
 Other 75 (11.4) 29 (10.9) 46 (11.6)
CIED type
 Cardiac resynchronization therapy with defibrillator 79 (12.0) 26 (9.8) 53 (13.4) 0.38
 Cardiac resynchronization therapy with pacemaker 37 (5.6) 18 (6.8) 19 (4.8)
 Implantable cardioverter–defibrillator 152 (23.0) 64 (24.2) 88 (22.2)
 Pacemaker 393 (59.5) 157 (59.3) 236 (59.6)
 Time from the most recent CIED procedure to IE admission, years (median [IQR]) 1.6 [0.3, 3.9] 1.8 [0.4, 4.4] 1.5 [0.3, 3.6] 0.051
 Time from the index CIED procedure to IE admission, years (median [IQR]) 3.8 [0.9, 8.1] 3.8 [1.0, 7.9] 3.8 [0.9, 8.3] 0.84
 Prior left-sided prosthetic heart valve surgery 98 (14.8) 41 (15.5) 57 (14.4) 0.70
History of comorbidity
 Ischaemic heart disease 374 (56.6) 157 (59.3) 217 (54.8) 0.26
 Heart failure 355 (53.7) 151 (57.0) 204 (51.5) 0.17
 Atrial fibrillation 341 (51.6) 132 (49.8) 209 (52.8) 0.45
 Stroke 101 (15.3) 38 (14.3) 63 (15.9) 0.58
 Hypertension 485 (73.4) 193 (72.8) 292 (73.7) 0.80
 Diabetes 234 (35.4) 104 (39.3) 130 (32.8) 0.09
 Chronic obstructive pulmonary disease 109 (16.5) 48 (18.1) 61 (15.4) 0.36
 Cancer 131 (19.8) 59 (22.3) 72 (18.2) 0.20
 Chronic renal disease 131 (19.8) 56 (21.1) 75 (18.9) 0.49
 Liver disease 37 (5.6) 22 (8.3) 15 (3.8) 0.01
Concomitant pharmacotherapy
 Cholesterol-lowering drugs 383 (57.9) 146 (55.1) 237 (59.9) 0.23
 Beta-blockers 424 (64.2) 166 (62.6) 258 (65.2) 0.51
 Calcium channel blockers 133 (20.1) 41 (15.5) 92 (23.2) 0.01
 Renin angiotensin system inhibitors 404 (61.1) 158 (59.6) 246 (62.1) 0.52
 Acetylsalicylic acid 220 (33.3) 96 (36.2) 124 (31.3) 0.19
 Adenosine diphosphate receptor inhibitors 96 (14.5) 38 (14.3) 58 (14.7) 0.91
 Anticoagulants 334 (50.5) 126 (47.6) 208 (52.5) 0.21
 Immunosuppressive 11 (1.7) 4 (1.5) 7 (1.8) 0.80

No significant differences in comorbidity status were identified between the two groups, except that diagnosed liver disease was more common in the non-reimplantation group than in the reimplantation group (8.3 vs. 3.8%, P = 0.01).

Pacemakers were the most prevalent CIED type across the entire cohort (59.5%), with no significant differences in the distribution of CIED types between the reimplantation and non-reimplantation group. However, the indications, defined as the diagnoses timely associated with the initial CIED implantation, differed significantly between groups (Table 2); atrioventricular block (AVB2/3) was significantly more frequent in the reimplantation group (32.8 vs. 18.5%, P < 0.001), as was secondary prevention among patients with an ICD or CRT-D (70.2 vs. 29.8%, P = 0.02), whereas SSS was significantly more frequent in the non-reimplantation group (22.6 vs. 14.7%, P = 0.009). In a supplementary analysis, atrioventricular block (AVB2/3) was more frequent among patients aged >80 years (37.3%) compared with those aged 70–80 years (22.1%) and <70 years (26.2%). In contrast, ICD therapy was less common among patients aged >80 years (7.3 vs. 22.9% and 32.8%), as was a history of VT/VF (3.3 vs. 7.1% and 11.5%).

Table 2.

Diagnoses timely associated with initial CIED implantation

Variable Total (n = 661) No reimplantation (n = 265) Reimplantation (n = 396) P-value
Cardiac arrest 37 (5.6) 12 (4.5) 25 (6.3) 0.33
Ventricular tachycardia and ventricular fibrillation 52 (7.9) 16 (6.0) 36 (9.1) 0.15
First-degree atrioventricular block ≤3
Second-degree or third-degree atrioventricular block 179 (27.1) 49 (18.5) 130 (32.8) <0.001
Branch and fascicular block 14 (2.1) 7 (2.6) 7 (1.8) 0.44
Sick sinus syndrome (SSS)a 118 (17.9) 60 (22.6) 58 (14.7) 0.009
Heart failure 230 (34.8) 101 (38.1) 129 (32.6) 0.14
Ischaemic heart disease 194 (29.4) 90 (34.0) 104 (26.3) 0.03
Ion channel disorders b <3
Syncope c 70 (10.6) 34 (12.8) 36 (9.1) 0.13

aIncludes sinus bradycardia, sinus arrest and sinoatrial block.

bIon channel disorders include Brugada syndrome, long QT syndrome, and short QT syndrome.

cCovers the diagnosis of Vasovagal syncope and carotid sinus syncope.

Supplementary material online, Figure S1, illustrates microbial aetiology according to reimplantation status. Staphylococcus aureus was the most commonly identified bacteria overall. There were no significant differences in microbial aetiology between the reimplantation and non-reimplantation groups.

CIED reimplantation

The median time to reimplantation was 29 days [IQR: 19.0–42.0] after extraction. Figure 2A illustrates the cumulative incidence curve of reimplantation, with the cumulative incidence reaching 60.1% [95% CI: 56.3–63.8%]. A histogram of time from extraction to reimplantation (Figure 2B) shows that 62.6% of reimplantations occurred within 3–5 weeks after extraction. To provide a broader overview of patient outcomes, Figure 3 illustrates the cumulative incidence proportions of reimplantation, survival without reimplantation, and death within 90 days after extraction. At Day 90, 181 (27.4%) were alive without reimplantation, and 84 (12.7%) had died. Among the reimplanted patients, 10 died within the 90 day period.

Figure 2.

Figure 2

Cumulative incidence (A) and histogram (B) of reimplantation within 90 days after CIED extraction.

Figure 3.

Figure 3

Cumulative incidence proportions of reimplantation, survival without reimplantation, and death within 90 days after CIED extraction. Ten patients were reimplanted and died within the 90 days.

Figure 4 illustrates the transition of CIED types from the most recent CIED procedure prior to extraction to the reimplanted device. Compared to pre-extraction, the proportion of single-chamber pacemakers increased (104 before vs. 132 after), while the use of dual-chamber pacemakers declined (289 before vs. 102 after). In contrast, the proportion of CRT-P, CRT-D, and ICD devices did not change substantially. Among the reimplanted patients, 58 (14.7%) received a leadless pacemaker or a subcutaneous ICD (S-ICD).

Figure 4.

Figure 4

Transitions between initial and reimplanted CIED types. CRTD, cardiac resynchronization therapy with defibrillator. CRTP, cardiac resynchronization therapy with pacemaker. Dual-chamber ICD, dual-chamber implantable cardioverter–defibrillator. Single-chamber ICD, single-chamber implantable cardioverter–defibrillator. Dual-chamber PM, dual-chamber pacemaker. Single-chamber PM, single-chamber pacemaker.

Factors associated with reimplantation

Factors associated with CIED reimplantation in the cause-specific Cox regression model are shown in Supplementary material online, Figure S2. The atrioventricular block (AVB2/3) as the diagnosis timely associated with the initial CIED implantation was significantly associated with a higher rate of reimplantation, with a HR of 1.53 [95% CI: 1.18–1.97]. In contrast, SSS, when present as the implantation-related diagnosis, was significantly associated with a lower rate of reimplantation (HR: 0.71 [95% CI: 0.52–0.97]). Additionally, atrial fibrillation as a comorbidity and age over 80 years, compared to those under 70 years, were also associated with a significantly higher rate of reimplantation, with a HR of 1.32 [95% CI: 1.07–1.62]) and 1.35 [95% CI: 1.02–1.80], respectively.

All-cause mortality and infective endocarditis-related outcomes after cardiac implantable electronic device extraction

The non-reimplantation and reimplantation group had similar cumulative incidence rates of IE readmissions (5.0% [95% CI: 2.6–8.7] (n = 10) vs. (3.6% [95% CI: 2.1–5.8] (n = 14); P = 0.41), relapse IE (≤3 observations in both groups), recurrent bacteraemia with IE (2.5% [95% CI: 0.95–5.5] (n = 5) vs. 1.8% [95% CI: 0.8–3.6] (n = 7); P = 0.55), recurrent bacteraemia without IE (≤3 observations in the non-reimplantation group vs. 1.6% [95% CI: 0.7–3.2] (n = 6) in the reimplantation group). The 6 month cumulative incidence of mortality was also similar between the non-reimplantation and reimplantation group 11.2% [95% CI: 7.0–16.4] (n = 19) vs. (7.0% [95% CI: 4.7–10.0] (n = 26); P = 0.11). There was no significant difference in recurrent bacteraemia with IE between patients reimplanted ≤14 days (≤3 observations) vs. >14 days (1.5% [95% CI: 0.6–3.3], n = 5), as well as between those reimplanted ≤29 days (2.3% [95% CI: 0.9–4.9], n = 5) vs. >29 days (≤3 observations).

Discussion

In this nationwide study of patients with IE who underwent CIED extraction without valve surgery, we identified three major findings. First, approximately 60% of the study population underwent CIED reimplantation within 3 months after extraction, with a median time to reimplantation of 29 days. Second, atrioventricular block (AVB2/3), atrial fibrillation as a comorbidity, and age over 80 years were associated with significantly higher rates of reimplantation, whereas SSS was associated with significantly lower reimplantation rate. Additionally, the reimplantation group had a lower median frailty score than the non-reimplantation group. Third, IE readmissions, relapse IE, recurrent bacteraemia with and without IE, and all-cause mortality rates were similar between the two groups and by timing of reimplantation.

CIED reimplantation

According to the 2023 ESC guidelines on managing IE,8 CIED reimplantation should be performed at a site distant from the previous generator, as late as possible and only once signs and symptoms of infection have resolved. Blood cultures should be negative for at least 72 h in patients without vegetations and for at least 2 weeks if vegetations are present. The recommendation for reimplantation is classified as Class I, Level of Evidence C, indicating expert consensus but limited clinical data. This is broadly consistent with the 2019 EHRA international consensus document,2 which places particular emphasis on the need for individualized decision-making, considering the clinical condition, infection severity, and ongoing device indications.

The observed extraction rate of 52.6% among patients with a CIED may partly reflect diagnostic uncertainty in patients with possible IE. In such cases, current ESC guidelines recommend device extraction as a Class IIa indication, allowing for a more conservative approach based on individual assessment. This may have contributed to the size and characteristics of the study population included in our analysis. Additionally, our study is based on nationwide data covering all hospital types, providing a more complete and unselected population. Previous studies22–25 have often been conducted in highly specialized tertiary centres, where reported extraction rates have varied widely (11.5–79.7%), potentially reflecting other extraction strategies.

In this nationwide study, the overall reimplantation rate of ∼60% is consistent with previous reports, which have documented reimplantation rates ranging from 57.7 to 80.7%.5,26,27 These findings indicate that the majority of patients underwent CIED reimplantation within 3 months post-extraction with variations across different study populations and clinical settings. Notably, the study5 with the reimplantation rate closest to ours (57.7%) was based on a multicentre registry including 434 patients across 10 centres, similar to our nationwide data. In contrast, the other studies were based on data from single centres, potentially limiting the generalizability of their results due to selection bias or specific local treatment strategies.28

In our cohort, more than half (62.6%) of reimplantations occurred within 3–5 weeks after extraction, with a median time of 29 days. According to the 2023 ESC guidelines on managing IE,8 antibiotic treatment is generally recommended for 2–6 weeks, depending on whether the infection involves a native or prosthetic valve, whether it is isolated left- or right-sided IE, as well as the causative pathogen. This recommended duration is based on empirical evidence, as no randomized data have been published.

The lack of a significant association between CIED type (ICD, CRT-P, and CRT-D) and reimplantation should be interpreted with caution, as this may reflect limited statistical power rather than a true absence of difference. It is noteworthy that reimplantation was not performed in a substantial proportion of patients across all CIED types, suggesting that continued device therapy was not always clinically necessary. These findings may highlight the importance of reassessing implantation and replacement indications, particularly in patients with an increased risk of CIED-related infection.

The transition from dual-chamber to single-chamber pacemakers likely reflects a principle of using the simplest effective CIED type. Minimizing hardware complexity by reducing the number of leads and chambers not only aligns with best practice but may also lower procedural risks,29,30 particularly in a frail patient group with a history of IE. Another possible explanation is the increased use of leadless devices, which are predominantly single-chamber systems and are considered safer following CIED infections due to their lower complication rates, including reduced reinfection risk.31,32Additionally, fewer patients may now meet the criteria for dual-chamber pacing. Meanwhile, differences in the use of CRT-P, CRT-D, and ICD devices were small and not statistically significant, suggesting that the trend primarily affected conventional pacemaker therapy.

A key challenge in the reimplantation process is determining the optimal timing to balance infection clearance with the patient’s cardiac dependence on CIEDs. This ‘critical decision window’ requires clinicians to carefully evaluate both the type of device to reimplant and the most appropriate timing, aiming to minimize the risk of recurrent infection while ensuring necessary CIED treatment. As reported in previous studies, the timing of reimplantation may affect the risk of device reinfection.33 In our study, no significant difference in the rate of recurrent bacteraemia with IE was observed when comparing patients reimplanted within 14 days vs. later. The overall number of events was small in both groups, indicating a generally low risk of reinfection and no evidence of increased risk associated with earlier reimplantation in selected patients. A randomized clinical trial (POET-PM) is currently underway to address this very question (ClinicalTrials.gov identifier: NCT06250985).

Factors associated with reimplantation

Our findings align with previous studies,27 which indicate that atrioventricular block (AVB2/3) and atrial fibrillation as a comorbidity are significant factors associated with CIED reimplantation—likely due to the critical nature of these conditions,34,35 especially AVB2/3 as a pacing indication. In contrast, SSS was significantly associated with a lower rate of reimplantation. This trend is consistent with prior research, suggesting that clinicians may be more cautious about reimplantation when pacing needs are less urgent. Overall, the concordance between our results and earlier studies underscores the notion that the severity of the underlying conduction disorder plays a pivotal role in reimplantation decisions. Although the higher prevalence of reimplantation in men compared with women lost statistical significance after adjustment, this finding aligns with previous studies showing that women are generally less likely to receive device implantation overall.36–39 The lack of a significant association between ICD and reimplantation is noteworthy, given that ICD recipients often have severe underlying cardiac disease, which would typically suggest a strong need for reimplantation. However, some may transition to palliative care, thereby reducing reimplantations. Although age >80 years was associated with a higher prevalence of reimplantation, the age itself alone does not imply a palliative approach. This association may reflect a selection bias, as only elderly patients with sufficient functional status and life expectancy would have been considered for reimplantation, whereas frailer patients may have transitioned to palliative care. Furthermore, this finding may also be related to differences in device indication, as pacing indications such as second- and third-degree AV block were more common among patients over 80 years. Others may experience improved left ventricular function or decreased arrhythmic risk post-extraction, obviating the need for, or the strength of the indication for a new ICD. In a supplementary analysis restricted to patients with an ICD or CRT-D, secondary prevention ICDs were significantly more frequent in the reimplantation group suggesting that indication type may influence reimplantation decisions in clinical practice. We also observed that patients who did not undergo reimplantation had a higher frailty score, highlighting the complexity of managing comorbid populations where the risks of reimplantation may outweigh its benefits.30

Furthermore, our data indicate a low rate of IE readmissions and reinfection in both the reimplantation and non-reimplantation groups, aligning with other studies.5 This supports a selective approach to reimplantation without substantially increasing the risk of infection. Nevertheless, we observed higher mortality in the non-reimplantation group, although the difference was not statistically significant. This finding is consistent with previous studies.27,40 One study40 reported that the majority of deaths were non-cardiac and unrelated to the absence of a CIED, thereby reinforcing the theory that increased mortality in the non-reimplantation group may be driven by higher frailty, greater comorbidity burdens, and a poorer overall prognosis, which may contribute to selection bias.

Strength and limitations

A major strength of this study is the use of high quality, nationwide registry-based data, which allows for accurate patient identification and outcome assessment across multiple registries. The inclusion of validated diagnostic and procedural codes with high PPVs for both IE diagnoses and CIED extraction codes, as shown in previous Danish validation studies15,17 including the NIDUS design study,41 supports the accuracy of case ascertainment. This, along with complete nationwide coverage and no loss to follow-up, enhances the reliability and generalizability of our findings.

However, several limitations should be acknowledged. First, the observational study design inherently limits causal inference. Second, despite adjusting for potential confounders, residual confounding may persist due to the absence of detailed clinical data, including the classification of IE (e.g. left-sided vs. CIED infection, and lead vs. pocket infection), precise CIED indication, antibiotic treatment strategies, imaging results, microbiological findings from extracted devices, data on extraction completeness (i.e. complete vs. incomplete extraction), peri- or post-procedural complications, clinical decision-making processes, and patient preferences. Additionally, we did not have access to data on temporary pacemaker use after extraction, including the proportion of patients requiring temporary pacing or the duration of support. Furthermore, data on pacemaker interrogation or telemetry findings before and after extraction were not available, preventing a comprehensive assessment of pacing requirements. Although the risk of misclassification is likely minimal given the high PPVs, it cannot be fully excluded, particularly for differentiating possible from definite CIED-related infections. Lastly, the timing analysis is limited by the small number of patients reimplanted within 14 days and by the clinical decision-making that inherently influences the timing of reimplantation.

Conclusion

In this nationwide study of patients with IE who underwent CIED extraction without valve surgery, we found that ∼60% of the study population underwent CIED reimplantation within 3 months following extraction, with a median time to reimplantation of 29 days. Second- and third-degree AVB, atrial fibrillation, and age over 80 years were associated with significantly higher reimplantation rates. The cumulative incidences of IE readmissions, recurrent bacteraemia, and all-cause mortality were low with no significant difference by reimplantation status or timing. We also observed a transition from dual- to single-chamber pacemakers following reimplantation. Our findings highlight the complexity of CIED reimplantation decisions, emphasizing the importance of individualized patient evaluation to optimize clinical outcomes. Future research should focus on strategies to balance the risks of early vs. delayed reimplantation and strategies to balance the risk of reimplantation vs. no reimplantation.

Supplementary Material

oeag008_Supplementary_Data

Contributor Information

Mohammed Bakir Ahmad Lafta, Department of Cardiology, Copenhagen University Hospital—Rigshospitalet, Blegdamsvej 9, 2100 Copenhagen, Denmark.

Amna Alhakak, Department of Cardiology, Copenhagen University Hospital—Rigshospitalet, Blegdamsvej 9, 2100 Copenhagen, Denmark.

Lauge Østergaard, Department of Cardiology, Copenhagen University Hospital—Rigshospitalet, Blegdamsvej 9, 2100 Copenhagen, Denmark.

Niels Eske Bruun, Department of Cardiology, Zealand University Hospital, Sygehusvej 10, 4000 Roskilde, Denmark; Department of Clinical Medicine, University of Copenhagen, Blegdamsvej 3B, 2200 Copenhagen, Denmark.

Anne-Christine Ruwald, Department of Cardiology, Copenhagen University Hospital—Rigshospitalet, Blegdamsvej 9, 2100 Copenhagen, Denmark; Department of Cardiology, Zealand University Hospital, Sygehusvej 10, 4000 Roskilde, Denmark.

Melanie Vuong Le, Department of Cardiology, Zealand University Hospital, Sygehusvej 10, 4000 Roskilde, Denmark.

Berit Philbert, Department of Cardiology, Copenhagen University Hospital—Rigshospitalet, Blegdamsvej 9, 2100 Copenhagen, Denmark.

Michael Vinther, Department of Cardiology, Copenhagen University Hospital—Rigshospitalet, Blegdamsvej 9, 2100 Copenhagen, Denmark.

Peter Godsk Jørgensen, Department of Cardiology, Copenhagen University Hospital—Herlev and Gentofte, Borgmester Ib Juuls Vej 1, 2730 Herlev, Denmark.

Eva Havers-Borgersen, Department of Cardiology, Copenhagen University Hospital—Rigshospitalet, Blegdamsvej 9, 2100 Copenhagen, Denmark; Department of Cardiology, Zealand University Hospital, Sygehusvej 10, 4000 Roskilde, Denmark.

Louise Kruse Jensen, Department of Veterinary and Animal Sciences, Section of Pathobiological Sciences, University of Copenhagen, 1870 Frederiksberg C, Denmark.

Jonas Agerlund Povlsen, Department of Cardiology, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, 8200 Aarhus N, Denmark.

Jens Cosedis Nielsen, Department of Cardiology, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, 8200 Aarhus N, Denmark; Department of Clinical Medicine, Aarhus University, Nordre Ringgade 1, 8000 Aarhus C, Denmark.

Jens Brock Johansen, Department of Cardiology, Odense University Hospital, J.B. Winsløws Vej 4, 5000 Odense C, Denmark.

Marianne Voldstedlund, Department of Data Integration and Analysis, Statens Serum Institute, Artillerivej 5, 2300 Amager, Copenhagen, Denmark.

Claus Moser, Department for Immunology and Microbiology, University of Copenhagen, Blegdamsvej 3B, 2200 Copenhagen, Denmark; Department of Clinical Microbiology, Copenhagen University Hospital—Rigshospitalet, Blegdamsvej 9, 2100 Copenhagen, Denmark.

Henning Bundgaard, Department of Cardiology, Copenhagen University Hospital—Rigshospitalet, Blegdamsvej 9, 2100 Copenhagen, Denmark; Department of Clinical Medicine, University of Copenhagen, Blegdamsvej 3B, 2200 Copenhagen, Denmark.

Lars Køber, Department of Cardiology, Copenhagen University Hospital—Rigshospitalet, Blegdamsvej 9, 2100 Copenhagen, Denmark; Department of Clinical Medicine, University of Copenhagen, Blegdamsvej 3B, 2200 Copenhagen, Denmark.

Emil Fosbøl, Department of Cardiology, Copenhagen University Hospital—Rigshospitalet, Blegdamsvej 9, 2100 Copenhagen, Denmark; Department of Clinical Medicine, University of Copenhagen, Blegdamsvej 3B, 2200 Copenhagen, Denmark.

Supplementary material

Supplementary material is available at European Heart Journal Open online.

Funding

This project is supported by a research scholarship administered by Copenhagen University Hospital—Rigshospitalet, Department of Cardiology, Heart Centre. (Grand no. 228101200).

Data availability

The data in this study are provided by Statistics Denmark. Although the data are not publicly available due to Danish data protection regulations, access can be granted to authorized researchers following approval from the relevant authorities.

References

  • 1. Greenspon  AJ, Patel  JD, Lau  E, Ochoa  JA, Frisch  DR, Ho  RT, Pavri  BB, Kurtz  SM. 16-year trends in the infection burden for pacemakers and implantable cardioverter-defibrillators in the United States 1993 to 2008. J Am Coll Cardiol  2011;58:1001–1006. [DOI] [PubMed] [Google Scholar]
  • 2. Blomström-Lundqvist  C, Traykov  V, Erba  PA, Burri  H, Nielsen  JC, Bongiorni  MG, Poole  J, Boriani  G, Costa  R, Deharo  J-C, Epstein  LM, Saghy  L, Snygg-Martin  U, Starck  C, Tascini  C, Strathmore  N, Kalarus  Z, Boveda  S, Dagres  N, Rinaldi  CA, Biffi  M, Gellér  L, Sokal  A, Birgersdotter-Green  U, Lever  N, Tajstra  M, Kutarski  A, Rodríguez  DA, Hasse  B, Zinkernagel  A, Mangoni  E. European Heart Rhythm Association (EHRA) international consensus document on how to prevent, diagnose, and treat cardiac implantable electronic device infections-endorsed by the Heart Rhythm Society (HRS), the Asia Pacific Heart Rhythm Society (APHRS), the Latin American Heart Rhythm Society (LAHRS), International Society for Cardiovascular Infectious Diseases (ISCVID) and the European Society of Clinical Microbiology and Infectious Diseases (ESCMID) in collaboration with the European Associatio. Europace  2020;22:515–516.31702000 [Google Scholar]
  • 3. Ahmed  FZ, Fullwood  C, Zaman  M, Qamruddin  A, Cunnington  C, Mamas  MA, Sandoe  J, Motwani  M, Zaidi  A. Cardiac implantable electronic device (CIED) infections are expensive and associated with prolonged hospitalisation: UK Retrospective Observational Study. PLoS One  2019;14:e0206611. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 4. Lambert  CT, Tarakji  KG. Cardiac implantable electronic device infection. Cleve Clin J Med  2017;84:47–53. [DOI] [PubMed] [Google Scholar]
  • 5. Boyle  TA, Uslan  DZ, Prutkin  JM, Greenspon  AJ, Baddour  LM, Danik  SB, Tolosana  JM, Le  K, Miro  JM, Peacock  J, Sohail  MR, Vikram  HR, Carrillo  RG. Reimplantation and repeat infection after cardiac-implantable electronic device infections: experience from the MEDIC (multicenter electrophysiologic device infection cohort) database. Circ Arrhythm Electrophysiol  2017;10:e004822. [DOI] [PubMed] [Google Scholar]
  • 6. Olsen  T, Jørgensen  OD, Nielsen  JC, Thøgersen  AM, Philbert  BT, Frausing  MHJP, Sandgaard  NCF, Johansen  JB. Risk factors for cardiac implantable electronic device infections: a nationwide Danish study. Eur Heart J  2022;43:4946–4956. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 7. Kusumoto  FM, Schoenfeld  MH, Wilkoff  BL, Berul  CI, Birgersdotter-Green  UM, Carrillo  R, Cha  Y-M, Clancy  J, Deharo  J-C, Ellenbogen  KA, Exner  D, Hussein  AA, Kennergren  C, Krahn  A, Lee  R, Love  CJ, Madden  RA, Mazzetti  HA, Moore  JC, Parsonnet  J, Patton  KK, Rozner  MA, Selzman  KA, Shoda  M, Srivathsan  K, Strathmore  NF, Swerdlow  CD, Tompkins  C, Wazni  O. 2017 HRS expert consensus statement on cardiovascular implantable electronic device lead management and extraction. Heart Rhythm  2017;14:e503–e551. [DOI] [PubMed] [Google Scholar]
  • 8. Delgado  V, Ajmone Marsan  N, de Waha  S, Bonaros  N, Brida  M, Burri  H, Caselli  S, Doenst  T, Ederhy  S, Erba  PA, Foldager  D, Fosbøl  EL, Kovac  J, Mestres  CA, Miller  OI, Miro  JM, Pazdernik  M, Pizzi  MN, Quintana  E, Rasmussen  TB, Ristić  AD, Rodés-Cabau  J, Sionis  A, Zühlke  LJ, Borger  MA, Iung  B, Prendergast  B, Abdelhamid  M, Adamo  M, Asteggiano  R, Baddour  LM, Čelutkienė  J, Chambers  J, Deharo  J-C, Doehner  W, Dos Subira  L, Duval  X, Falk  V, Fauchier  L, Fernandez-Hidalgo  N, Giske  C, Gombošová  A, Habib  G, Ibanez  B, Jaarsma  T, Køber  L, Koskinas  KC, Kotecha  D, Landmesser  U, Lauck  SB, Lewis  BS, Løchen  M-L, McEvoy  JW, Mihaylova  B, Mindham  R, Neubeck  L, Nielsen  JC, Obadia  J-F, Pasquet  AA, Petersen  S, Prescott  E, Price  S, Rakisheva  A, Rao  A, Rouzet  F, Sandoe  J, Schnabel  RB, Selton-Suty  C, Sondergaard  L, Thornhill  M, Toutouzas  K, Van de Veire  N, Vilacosta  I, Vrints  C, Wendler  O, Benchabi  Y, Chilingaryan  A, Reinstadler  SJ, Samadov  F, Paelinck  B, Kušljugić  Z, Kinova  E, Cikes  M, Michaloliakos  I, Mates  M, Povlsen  JA, Abdelghani  M, Küünal-Arge  L, Rajala  H, Selton-Suty  C, Pagava  Z, Franz  M, Patrianakos  A, Barta  J, Hrafnkelsdóttir  ÞJ, Moore  D, Orvin  K, Oliva  F, Zhussupova  G, Bajraktari  G, Kerimkulova  A, Kamzola  G, Habib  P, Mizarienė  V, Sow  R, Demarco  DC, Panfile  E, Bendriss  L, Tanis  W, Mitevska  I, Aune  E, Antunes  M, Popescu  BA, Bini  R, Tesic  M, Orban  M, Bervar  M, Vilacosta  I, Christersson  C, Frank  M, Zakhama  L, Guler  GB, Cherniuk  S, Woldman  S, Srojidinova  N, Prescott  E, James  S, Arbelo  E, Baigent  C, Borger  MA, Buccheri  S, Ibanez  B, Køber  L, Koskinas  KC, McEvoy  JW, Mihaylova  B, Mindham  R, Neubeck  L, Nielsen  JC, Pasquet  AA, Rakisheva  A, Rocca  B, Rossello  X, Vaartjes  I, Vrints  C, Witkowski  A, Zeppenfeld  K. 2023 ESC guidelines for the management of endocarditis. Eur Heart J  2023;44:3948–4042. [DOI] [PubMed] [Google Scholar]
  • 9. Deharo  JC, Bongiorni  MG, Rozkovec  A, Bracke  F, Defaye  P, Fernandez-Lozano  I, Golzio  PG, Hansky  B, Kennergren  C, Manolis  AS, Mitkowski  P, Platou  ES, Love  C, Wilkoff  B. Pathways for training and accreditation for transvenous lead extraction: a European Heart Rhythm Association position paper. Europace  2012;14:124–134. [DOI] [PubMed] [Google Scholar]
  • 10. Khaloo  P, Uzomah  UA, Shaqdan  A, Ledesma  PA, Galvin  J, Ptaszek  LM, Ruskin  JN. Outcomes of patients hospitalized with cardiovascular implantable electronic device– related infective endocarditis. Prosthetic Valve Endocarditis, and Native Valve Endocarditis: a Nationwide Study 2003 to 2017. J Am Heart Assoc  2022;11:e025600. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 11. Lynge  E, Sandegaard  JL, Rebolj  M. The Danish national patient register. Scand J Public Health  2011;39:30–33. [DOI] [PubMed] [Google Scholar]
  • 12. Kildemoes H  W, Sørensen H  T, Hallas  J. The Danish national prescription registry. Scand J Public Health  2011;39:38–41. [DOI] [PubMed] [Google Scholar]
  • 13. Pedersen  CB. The Danish civil registration system. Scand J Public Health  2011;39:22–25. [DOI] [PubMed] [Google Scholar]
  • 14. Voldstedlund MAV  M, Haarh  M, Mølbak  K. Miba board of representatives the the danish microbiology database (MiBa 2010 to 2013). Euro Surveill  2014;19:20667. [DOI] [PubMed] [Google Scholar]
  • 15. Ostergaard  L, Adelborg  K, Sundboll  J, Pedersen  L, Loldrup Fosbol  E, Schmidt  M. Positive predictive value of infective endocarditis in the Danish National Patient Registry: a validation study. Epidemiol Infect  2018;146:1965–1967. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 16. Sundbøll  J, Adelborg  K, Munch  T, Frøslev  T, Sørensen  HT, Bøtker  HE, Schmidt  M. Positive predictive value of cardiovascular diagnoses in the Danish National Patient Registry: a validation study. BMJ Open  2016;6:e012832. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 17. Adelborg  K, Sundbøll  J, Munch  T, Frøslev  T, Sørensen  HT, Bøtker  HE, Schmidt  M. Positive predictive value of cardiac examination, procedure and surgery codes in the Danish National Patient Registry: a population-based validation study. BMJ Open  2016;6:e012817. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 18. Bonnesen  K, Schmidt  M. Validity of prescription-defined and hospital-diagnosed hypertension compared with self-reported hypertension in Denmark. Clin Epidemiol  2024;16:249–256. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 19. Nielsen  GL, Sørensen  HT, Pedersen  AB, Sabroe  S. Analyses of data quality in registries concerning diabetes mellitus–a comparison between a population based hospital discharge and an insulin prescription registry. J Med Syst  1996;20:1–10. [DOI] [PubMed] [Google Scholar]
  • 20. Carstensen  B, Kristensen  JK, Marcussen  MM, Borch-Johnsen  K. The national diabetes register. Scand J Public Health  2011;39:58–61. [DOI] [PubMed] [Google Scholar]
  • 21. Gilbert  T, Neuburger  J, Kraindler  J, Keeble  E, Smith  P, Ariti  C, Arora  S, Street  A, Parker  S, Roberts  HC, Bardsley  M, Conroy  S. Development and validation of a hospital frailty risk score focusing on older people in acute care settings using electronic hospital records: an observational study. The Lancet  2018;391:1775–1782. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 22. Donal  E, Tribouilloy  C, Sadeghpour  A, Laroche  C, Tude Rodrigues  AC, Pereira Nunes  MdC, Kang  D-H, Hernadez-Meneses  M, Kobalava  Z, De Bonis  M, Dworakowski  R, Ivanovic  B, Holicka  M, Kitai  T, Cruz  I, Huttin  O, Colonna  P, Lancellotti  P, Habib  G. Cardiac device-related infective endocarditis need for lead extraction whatever the device according to the ESC EORP EURO-ENDO registry. Eur Heart J Open  2023;3:oead064. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 23. Athan  E, Chu  VH, Tattevin  P, Selton-Suty  C, Jones  P, Naber  C, JM  Miró, S  Ninot, N  Fernández-Hidalgo, E  Durante-Mangoni, D  Spelman, B  Hoen, T  Lejko-Zupanc, E  Cecchi, F  Thuny, MM  Hannan, P  Pappas, M  Henry, VG  Fowler  Jr, AL  Crowley, A  Wang; ICE-PCS Investigators . Clinical characteristics and outcome of infective endocarditis involving implantable cardiac devices. JAMA  2012;307:1727–1735. [DOI] [PubMed] [Google Scholar]
  • 24. De Ciancio  G, Erpelding  M-L, Filippetti  L, Goehringer  F, Blangy  H, Huttin  O, Agrinier  N, Juillière  Y, Sadoul  N, Selton-Suty  C. Adherence to diagnostic and therapeutic practice guidelines for suspected cardiac implantable electronic device infections. Arch Cardiovasc Dis  2021;114:634–646. [DOI] [PubMed] [Google Scholar]
  • 25. Sciria  CT, Kogan  EV, Mandler  AG, Yeo  I, Simon  MS, Kim  LK, Ip  JE, Liu  CF, Markowitz  SM, Lerman  BB, Thomas  G, Cheung  JW. Low utilization of lead extraction among patients with infective endocarditis and implanted cardiac electronic devices. J Am Coll Cardiol  2023;81:1714–1725. [DOI] [PubMed] [Google Scholar]
  • 26. De Schouwer  K, Vanhove  R, Garweg  C, Voros  G, Haemers  P, Ector  J, Willems  R. Re-implantation after extraction of a cardiac implantable electronic device. Acta Cardiol  2020;75:505–513. [DOI] [PubMed] [Google Scholar]
  • 27. Döring  M, Hienzsch  L, Ebert  M, Lucas  J, Dagres  N, Kühl  M, Hindricks  G, Knopp  H, Richter  S. Extraction of infected cardiac implantable electronic devices and the need for subsequent re-implantation. Int J Cardiol  2020;309:84–91. [DOI] [PubMed] [Google Scholar]
  • 28. Kotani  Y, Turi  S, Ortalda  A, Baiardo Redaelli  M, Marchetti  C, Landoni  G, Bellomo  R. Positive single-center randomized trials and subsequent multicenter randomized trials in critically ill patients: a systematic review. Crit Care  2023;27:1–12. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 29. Gillis  AM, Russo  AM, Ellenbogen  KA, Swerdlow  CD, Olshansky  B, Al-Khatib  SM, Beshai  JF, McComb  JM, Nielsen  JC, Philpott  JM, Shen  W-K. HRS/ACCF Expert Consensus Statement on Pacemaker Device and Mode Selection: developed in partnership between the Heart Rhythm Society (HRS) and the American College of Cardiology Foundation (ACCF) and in collaboration with the Society of Thoracic Surgeons. Heart Rhythm  2012;9:1344–1365. [DOI] [PubMed] [Google Scholar]
  • 30. Glikson  M, Nielsen  JC, Kronborg  MB, Michowitz  Y, Auricchio  A, Barbash  IM, Barrabés  JA, Boriani  G, Braunschweig  F, Brignole  M, Burri  H, Coats  AJS, Deharo  J-C, Delgado  V, Diller  G-P, Israel  CW, Keren  A, Knops  RE, Kotecha  D, Leclercq  C, Merkely  B, Starck  C, Thylén  I, Tolosana  JM, Leyva  F, Linde  C, Abdelhamid  M, Aboyans  V, Arbelo  E, Asteggiano  R, Barón-Esquivias  G, Bauersachs  J, Biffi  M, Birgersdotter-Green  U, Bongiorni  MG, Borger  MA, Čelutkienė  J, Cikes  M, Daubert  J-C, Drossart  I, Ellenbogen  K, Elliott  PM, Fabritz  L, Falk  V, Fauchier  L, Fernández-Avilés  F, Foldager  D, Gadler  F, De Vinuesa  PGG, Gorenek  B, Guerra  JM, Hermann Haugaa  K, Hendriks  J, Kahan  T, Katus  HA, Konradi  A, Koskinas  KC, Law  H, Lewis  BS, Linker  NJ, Løchen  M-L, Lumens  J, Mascherbauer  J, Mullens  W, Nagy  KV, Prescott  E, Raatikainen  P, Rakisheva  A, Reichlin  T, Ricci  RP, Shlyakhto  E, Sitges  M, Sousa-Uva  M, Sutton  R, Suwalski  P, Svendsen  JH, Touyz  RM, Van Gelder  IC, Vernooy  K, Waltenberger  J, Whinnett  Z, Witte  KK, Kronborg  MB, Michowitz  Y, Auricchio  A, Barbash  IM, Barrabés  JA, Boriani  G, Braunschweig  F, Brignole  M, Burri  H, Coats  AJS, Deharo  J-C, Delgado  V, Diller  G-P, Israel  CW, Keren  A, Knops  RE, Kotecha  D, Leclercq  C, Merkely  B, Starck  C, Thylén  I, Tolosana  JM. ESC guidelines on cardiac pacing and cardiac resynchronization therapy. Eur Heart J  2021;42:3427–3520.34455430 [Google Scholar]
  • 31. Bicong  L, Allen  JC, Arps  K, Al-Khatib  SM, Bahnson  TD, Daubert  JP, Frazier-Mills  C, Hegland  DD, Jackson  KP, Jackson  LR, Lewis  RK, Pokorney  SD, Sun  AY, Thomas  KL, Piccini  JP. Leadless pacemaker implantation after lead extraction for cardiac implanted electronic device infection. J Cardiovasc Electrophysiol  2022;33:464–470. [DOI] [PubMed] [Google Scholar]
  • 32. Ngo  L, Nour  D, Denman  RA, Walters  TE, Haqqani  HM, Woodman  RJ, Ranasinghe  I. Safety and efficacy of leadless pacemakers: a systematic review and meta-analysis. J Am Heart Assoc  2021;10:19212. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 33. Chew  D, Somayaji  R, Conly  J, Exner  D, Rennert-May  E. Timing of device reimplantation and reinfection rates following cardiac implantable electronic device infection: a systematic review and meta-analysis. BMJ Open  2019;9:e029537. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 34. Zhang  J, Liu  J, Ye  M, Zhang  M, Yao  F, Cheng  Y. Incidence and risk factors associated with atrioventricular block in the general population: the atherosclerosis risk in communities study and Cardiovascular Health Study. BMC Cardiovasc Disord  2024;24:1–12. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 35. Aste  M, Brignole  M. Syncope and paroxysmal atrioventricular block. J Arrhythm  2017;33:562–567. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 36. Ingelaere  S, Hoffmann  R, Guler  I, Vijgen  J, Mairesse  GH, Blankoff  I, Vandekerckhove  Y, le Polain de Waroux  J-B, Vandenberk  B, Willems  R. Inequality between women and men in ICD implantation. Int J Cardiol Heart Vasc  2022;41:101075. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 37. Vijayarajan  V, Kritharides  L, Brieger  D, Cheng  YY, Chow  V, Ng  ACC. Sex differences in rates of permanent pacemaker implantation and in-hospital complications: a statewide cohort study of over 7 million persons from 2009–2018. PLoS One  2022;17:e0272305. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 38. Chen  RH, Chen  KP, Hua  W, Xu  J, Chen  L, Su  YG, Zou  J-G, Yan  J, Wang  J-F, Tang  B-P, Xiang  M-X, Zhang  S. The gender difference of utilization of cardiac implantable electronic device in China: data from Arrhythmia Interventional Therapy Data Registry. J Geriatr Cardiol  2018;15:310. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 39. Hernandez  AF, Fonarow  GC, Liang  L, Al-Khatib  SM, Curtis  LH, LaBresh  KA, Yancy  CW, Albert  NM, Peterson  ED. Sex and racial differences in the use of implantable cardioverter-defibrillators among patients hospitalized with heart failure. JAMA  2007;298:1525–1532. [DOI] [PubMed] [Google Scholar]
  • 40. Al-Hijji  MA, Killu  AM, Yousefian  O, Hodge  DO, Park  JY, Hebsur  S, El Sabbagh  A, Pretorius  VG, Ackerman  MJ, Friedman  PA, Birgersdotter-Green  U, Cha  Y-M. Outcomes of lead extraction without subsequent device reimplantation. Europace  2017;19:1527–1534. [DOI] [PubMed] [Google Scholar]
  • 41. Graversen  PL, Hadji-Turdeghal  K, Møller  JE, Bruun  NE, Laghmoch  H, Jensen  AD, Petersen  JK, Bundgaard  H, Iversen  K, Povlsen  JA, Moser  C, Smerup  M, Jensen  HS, Søgaard  P, Helweg-Larsen  J, Faurholt-Jepsen  D, Østergaard  L, Køber  L, Fosbøl  EL. NatIonal Danish endocarditis stUdieS—design and objectives of the NIDUS registry. Am Heart J  2024;268:80–93. [DOI] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

oeag008_Supplementary_Data

Data Availability Statement

The data in this study are provided by Statistics Denmark. Although the data are not publicly available due to Danish data protection regulations, access can be granted to authorized researchers following approval from the relevant authorities.


Articles from European Heart Journal Open are provided here courtesy of Oxford University Press on behalf of the European Society of Cardiology

RESOURCES