Abstract
Introduction
Accurately measuring tissue thickness is a crucial technical aspect and a source of bias in biomechanical analysis, as even minor errors can substantially affect stress, elasticity, and tissue behavior. This study analyzes the reproducibility and consistency of specimen thickness measurements by experienced users using a digital caliper under two protocols and a specialized device under a third, also assessing the impact on biomechanical properties.
Method
The current study is a methodological study in which we examined the thickness of the porcine arterial wall, specifically segments from the aorta, carotid, and coronary arteries. For the first two protocols, thickness measurements were performed using a digital vernier caliper (Multicomp PRO MP012475), whereas a dedicated digital thickness gauge (Mitutoyo 547-500S, Kawasaki, Japan) was employed for the third protocol. Biomechanical testing was conducted using a BioTester® 5000 (CellScale, Canada), fitted with two opposing BioRakes mounted on actuators to apply uniaxial tensile loading at 25% and 50% stretch.
Results
For coronary artery wall thickness measurements, significant protocol-dependent differences between novice users for Protocol 1 and Protocol 3 (p = 0.0384), and for intermediate users using the same protocols (p = 0.0122). The mechanical response of porcine vascular tissues at 25% and 50% stretch was not influenced by operator experience, as no statistically significant differences in Cauchy stress were observed among users across the three experimental protocols.
Conclusion
This study demonstrates that the method used to measure arterial wall thickness influences reproducibility, particularly in thin-walled vessels such as coronary arteries, and when performed by less experienced users.
Keywords: biomechanics, digital thickness gauge, digital vernier caliper, thickness, vascular tissue
1. Introduction
Technological progress has advanced significantly in recent years, particularly in the biomedical field, where challenges remain constant. Although multiple methods are currently available to address cardiovascular pathologies, they remain a significant public health problem in both developed and developing countries (Santos et al., 2025; Teo and Rafiq, 2021; Li et al., 2023). In addition to the drug and surgical therapies currently available, it is essential to understand the mechanisms underlying the occurrence and development of cardiovascular diseases as comprehensively as possible. In this regard, there remain uncertainties in characterizing the biomechanical behavior of soft tissues, such as vascular tissue, particularly given their anisotropy (Holzapfel et al., 2004; Wang et al., 2019). To better evaluate these properties, various calculation formulas are used, including Cauchy stress and Young’s modulus. The Cauchy stress tensor describes the state of stress at a point in a deformable body and represents the forces per unit area acting on the tissue. Young’s modulus, also known as the modulus of elasticity, is a property of a material that quantifies its stiffness, specifically the ratio of stress to strain in the elastic region (Hooglugt et al., 2022; Lisický et al., 2021). These formulas are based on the cross-sectional area of the tissue being analyzed and therefore require the most appropriate collection of sample dimensions. Various tools can be used to perform these measurements, each with its own perks and drawbacks. These include digital vernier calipers, micrometers, or thickness gauges (O’Lear et al., 2013; de Gelidi et al., 2017). Recently published papers from our team show that the method used to measure tissue thickness has a substantial impact on data quality: a digital thickness gauge yields more consistent and reliable measurements than a digital vernier caliper (Ion et al., 2024a; Ion et al., 2024b). Accurately measuring tissue thickness is a crucial technical aspect and a significant source of bias in biomechanical analysis, as even minor errors can substantially affect stress, elasticity, and tissue behavior calculations.
This study aims to analyze the reproducibility and consistency of arterial wall thickness measurements obtained with a standard digital vernier caliper and a specialized digital thickness gauge across examiners with different levels of experience, and to determine whether these thickness measurements influence the derived biomechanical profile of porcine aortic, carotid, and coronary artery walls.
2. Materials and methods
2.1. Vascular tissue samples
The current study is a methodological study in which we examined the thickness of the porcine arterial wall, specifically segments from the aorta, carotid arteries, and coronary arteries. All tissues were obtained from a local slaughterhouse, as these organs were designated for disposal. To ensure optimal preservation, the harvested tissues were promptly transported to the laboratory and stored at 4 °C. Following appropriate tissue preparation, 12 segments were excised from each artery, producing samples measuring 12 × 12 mm. Each specimen was subsequently stored in phosphate-buffered saline (PBS) until further analysis.
2.2. Thickness measurements protocols
Thickness measurements were obtained using two instruments with fundamentally different operating principles. The digital vernier caliper determines specimen thickness as the distance between two manually positioned jaws. Consequently, the recorded value is influenced by operator-dependent factors, including jaw alignment, selection of the contact location, and the magnitude of the applied force. In contrast, the digital thickness gauge employs a probe–anvil configuration with spring-regulated contact. This design delivers a consistent measuring force, thereby minimizing variability associated with tissue compression, particularly in compliant specimens, and reducing operator-dependent measurement bias. For the first two protocols, thickness measurements were performed using a digital vernier caliper (Multicomp PRO MP012475), whereas a dedicated digital thickness gauge (Mitutoyo 547-500S, Mitutoyo Corp., Kawasaki, Japan) was employed for the third protocol. Protocols I and II were designed to replicate common operator-dependent measurement strategies encountered when using a digital vernier caliper on small, square vascular specimens. Protocol I (side-midpoint measurements) models a user who preferentially positions the caliper centrally along each edge. Thickness was measured at the midpoint of each side, and the resulting values were averaged to obtain a representative specimen thickness. Protocol II (corner measurements) reflects an alternative approach in which the caliper is positioned near specimen corners or transition zones. These regions are more susceptible to local geometric variability, including edge curvature, minor surface irregularities, and potential misalignment, all of which may influence measurement readings. As in Protocol I, four measurements were obtained and averaged to determine the final specimen thickness. Given that caliper-based measurements inherently involve manual control of both contact positioning and applied pressure, the two protocols were specifically developed to capture realistic sources of user-dependent variability in thickness assessment. In Protocol III, sample thickness was measured with a Mitutoyo 547-500S digital thickness gauge, and the final value was obtained by averaging three consecutive measurements (Figure 1). To minimize experimental variability, all specimens were maintained in phosphate-buffered saline (PBS) throughout the measurement and testing procedures to preserve hydration. Measurements were performed at room temperature within a standardized time window following tissue harvesting to reduce time-dependent viscoelastic changes. Specimens were consistently oriented with the luminal surface facing upward, and care was taken to avoid pre-stretch or deformation prior to thickness measurement. The order of measurement protocols was standardized across all specimens (Protocol I, Protocol II, followed by Protocol III) to ensure consistency. To ensure consistent measurement orientation and to prevent repeated assessment of the same side or corner in Protocols I and II, one corner of each specimen was marked prior to measurement. This reference point defined the starting location and guided the sequential positioning of measurements across the specimen. Users performed measurements independently and were blinded to each other’s results. To minimize recall bias, measurements were recorded immediately and not revisited during subsequent protocols.
FIGURE 1.
Experimental workflow for arterial wall thickness measurement and mechanical characterization. Porcine arterial specimens (n = 12 per vessel type: aorta, carotid, and coronary) were harvested and prepared for thickness assessment and biomechanical testing. Wall thickness was measured using three protocols: Protocol I (side-midpoint measurements) and Protocol II (corner measurements) using a digital vernier caliper (Multicomp PRO MP012475), and Protocol III using a digital thickness gauge with controlled contact force (Mitutoyo 547-500S). In Protocols I and II, thickness was calculated as the average of four measurements (T1–T4), whereas in Protocol III, the mean of three repeated measurements at the same location was used. Following thickness determination, specimens were subjected to uniaxial tensile testing using a CellScale BioTester 5000. Mechanical properties were quantified by calculating Cauchy stress (kPa) at 25% and 50% stretch and Young’s modulus (kPa) from the linear region of the stress–strain response.
2.3. Biomechanical testing
Biomechanical testing was conducted using a BioTester® 5000 (CellScale, Waterloo, ON, Canada), fitted with two opposing BioRakes mounted on actuators to apply uniaxial tensile loading to the arterial wall (Figure 1). For each specimen, an initial gauge length of 10 mm was established, and the resulting force–displacement response was recorded. Samples were subjected to cyclic loading consisting of a 25% stretch followed by a 50% stretch, applied at rates of 1% s-1 and 2% s-1, respectively, for a total of 10 cycles each. Only data from the final cycle were used for statistical analysis to ensure mechanical stabilization of the tissue. Each loading cycle comprised 25 s of stretching followed by a 25-s recovery period. Based on the recorded data and using LabJoy 2.0 software (CellScale), the Cauchy stress (kPa) and Young’s modulus (kPa) were calculated. Cauchy stress (σ) was calculated as the ratio of the measured force to the specimen cross-sectional area (σ = F/A), where F represents the force recorded at 25% and 50% stretch, and A denotes the cross-sectional area, defined as the product of specimen width and wall thickness. Young’s modulus (E) was determined from the slope of the linear region of the stress–strain response (E = Δσ/Δε), evaluated over the strain interval corresponding to 25%–50% stretch during the final loading cycle.
2.4. Statistical analysis
Statistical analyses were performed using SPSS for Mac OS (version 29.0.2.0; SPSS Inc., Chicago, IL, USA). Continuous variables, including thickness, Cauchy stress, and Young’s modulus, are presented as mean ± standard deviation (SD). Differences between continuous variables were assessed using a one-way ANOVA test, followed by Tukey’s multiple comparisons test to adjust for pairwise comparisons. Comparisons were performed separately within each vessel type, with thickness measurements obtained from different protocols or users treated as independent groups for method comparison. For the purpose of method comparison, measurements obtained from different protocols or users were treated as independent groups, despite being derived from repeated assessments of the same specimens. This approach was adopted to enable direct group-wise comparisons within a unified analytical framework. However, it does not account for within-specimen correlations inherent to the study design.
3. Results
Arterial wall thickness measurements were compared across three measurement protocols for users with novice, intermediate, and expert levels of experience, and across three vessel types: porcine aorta, porcine carotid artery, and porcine coronary artery (Figure 2; Table 1). Across vessel types, both the magnitude and statistical significance of inter-protocol differences were strongly influenced by tissue thickness and operator experience. For the porcine aorta, inter-protocol variability was minimal, with absolute differences ≤0.18 mm and relative deviations generally below 10%, and no statistically significant differences were detected at any experience level (Figures 2A,D,G). Although novice users tended to overestimate thickness with caliper-based protocols relative to the digital thickness gauge (Protocol III), intermediate and expert users showed smaller, more consistent deviations, indicating improved measurement precision with experience. Similarly, carotid artery measurements did not differ significantly across protocols for any user group (Figures 2B,E,H), despite a greater spread of values than in the aorta. Notably, intermediate users systematically underestimated caliper-based methods, with deviations of approximately 16% relative to Protocol III, suggesting that moderately thick, compliant tissues are more sensitive to methodological differences and operator-dependent factors such as contact force and positioning. In contrast, the porcine coronary artery—the thinnest vessel examined—demonstrated clear protocol-dependent effects. Significant differences were observed between Protocol I and Protocol III for both novice (p = 0.0384; Figure 2C) and intermediate users (p = 0.0122; Figure 2F), while no significant differences were detected for expert users (Figure 2I). Caliper-based protocols consistently overestimated thickness in novice and intermediate groups, with relative differences of approximately 12%–14% compared with Protocol III. These findings highlight the increased susceptibility of thin-walled tissues to compression artifacts and alignment errors inherent to manual caliper measurements.
FIGURE 2.
Comparison of measurements from three experimental protocols across three porcine vascular tissues (aorta, carotid, and coronary artery walls), obtained by users with novice (A–C), intermediate (D–F), and expert (G–I) experience levels.
TABLE 1.
Quantitative comparison of arterial wall thickness measurements across protocols and user experience levels, including absolute and relative differences between caliper-based methods and digital thickness gauge measurements.
| Vessel type | User experience | Protocol I (mean ± SD) | Protocol II (mean ± SD) | Protocol III (mean ± SD) | Absolut difference | %Δ | ||||
|---|---|---|---|---|---|---|---|---|---|---|
| P1-P2 | P1-P3 | P2-P3 | P1 vs. P2 | P1 vs. P3 | P2 vs. P3 | |||||
| Porcine aorta | Novice | 2.08 ± 0.27 | 1.99 ± 0.27 | 1.89 ± 0.23 | 0.09 | 0.18 | 0.10 | 4.57% | 9.95% | 5.15% |
| Intermediate | 1.82 ± 0.17 | 1.81 ± 0.19 | 1.89 ± 0.23 | 0.01 | −0.07 | −0.08 | 0.76% | −3.65% | −4.38% | |
| Expert | 1.80 ± 0.19 | 1.84 ± 0.22 | 1.92 ± 0.25 | −0.04 | −0.12 | −0.08 | −2.33% | −6.25% | −4.02% | |
| Porcine carotid artery | Novice | 1.17 ± 0.33 | 1.18 ± 0.36 | 1.26 ± 0.35 | −0.01 | −0.08 | −0.07 | −1.12% | −6.79% | −5.74% |
| Intermediate | 1.05 ± 0.23 | 1.04 ± 0.25 | 1.25 ± 0.35 | 0.01 | −0.19 | −0.21 | 1.03% | −15.73% | −16.58% | |
| Expert | 1.16 ± 0.32 | 1.16 ± 0.36 | 1.28 ± 0.36 | −0.001 | −0.12 | −0.12 | −0.04% | −9.41% | −9.37% | |
| Porcine coronary artery | Novice | 0.67 ± 0.07 | 0.66 ± 0.09 | 0.59 ± 0.07 | 0.03 | 0.07 | 0.04 | 4.64% | 11.89% | 6.93% |
| Intermediate | 0.67 ± 0.04 | 0.64 ± 0.06 | 0.59 ± 0.06 | 0.001 | 0.08 | 0.07 | 1.16% | 14.42% | 13.10% | |
| Expert | 0.64 ± 0.07 | 0.67 ± 0.08 | 0.63 ± 0.06 | −0.02 | 0.02 | 0.04 | −3.85% | 2.80% | 6.91% | |
Overall, measurement variability decreased with increasing operator experience across all vessel types, with the most pronounced improvement observed in the coronary artery. Variability was inversely related to vessel wall thickness and amplified among less experienced users. Across all conditions, the digital thickness gauge (Protocol III) yielded systematically lower and more consistent measurements, supporting its reduced operator dependence and superior reproducibility.
To evaluate the reproducibility of each protocol regarding the user experience, thickness measurements obtained using each protocol were compared separately for each tissue type. As shown in Supplementary Figure S1A, when applying the first protocol to the porcine aortic wall, the novice user obtained significantly greater thickness measurements compared with both the intermediate (p = 0.0181) and expert users (p = 0.0097). In contrast, no significant differences among users were observed when using the second and third protocols (Supplementary Figures S1B, C1). Likewise, for the porcine carotid artery specimen, user experience did not significantly affect measurements for any of the three protocols (Supplementary Figure S1).
Subsequently, the specimens were subjected to uniaxial tensile loading at strains of 25% and 50% to assess their biomechanical properties. The thickness measurements obtained by each user using each protocol were then used to calculate Cauchy stress (kPa) and Young’s modulus (kPa). The mechanical response of porcine vascular tissues at 25% stretch was not influenced by operator experience, as no statistically significant differences in Cauchy stress were observed among the Novice, Intermediate, and Expert users across any of the three experimental protocols (for all p > 0.05) (Figure 3). While stress levels varied by anatomical location—with the aortic wall being the most resistant, followed by the carotid and coronary walls—the variability was consistent across the three users.
FIGURE 3.
Comparison of Cauchy stress (kPa) calculated using thickness measurements from the three protocols for each user for the porcine aortic wall (A–C), carotid artery wall (D–F), and coronary artery wall (G–I) subjected to 25% stretch.
The Young’s modulus of porcine aortic, carotid, and coronary artery walls at 25% stretch remained consistent across all user experience levels, with no significant differences found between the novice, intermediate, and expert groups (Figure 4). This uniformity was maintained across three consecutive experimental protocols, suggesting that all the protocols proposed and analyzed in the current study were independent of user experience. Moreover, similar results were observed when porcine vascular tissue was subjected to 50% stretch (Supplementary Figures S2, S3).
FIGURE 4.
Comparison of Young’s modulus (kPa) calculated using thickness measurements from the three protocols for each user for the porcine aortic wall (A–C), carotid artery wall (D–F), and coronary artery wall (G–I) subjected to 25% stretch.
4. Discussion
The main findings of this study demonstrate that the consistency of arterial wall thickness measurements improves with increasing operator experience, particularly in small vessels with thin walls, such as the coronary arteries. Novice and intermediate users exhibited protocol-dependent variability in their measurements, whereas these differences were no longer observed at the expert user. Despite this variability in raw thickness data, all three measurement protocols—whether using a digital vernier caliper or a dedicated digital thickness gauge—produced comparable biomechanical outcomes for Cauchy stress and Young’s modulus across all levels of user experience. This indicates that although operator experience and measurement technique can affect thickness measurements, the resulting biomechanical characterization of porcine aortic, carotid, and coronary arteries remains largely robust to these variations, mainly because of the high data distribution. Overall, the results support the reliability of biomechanical analyses when standardized thickness measurement protocols are used, while underscoring the importance of operator training to reduce measurement variability, particularly in thinner vascular tissues.
In our results, the clearest protocol-dependent differences were observed in the coronary artery for novice and intermediate users, whereas a user-specific difference was observed in the aorta wall under Protocol I, with the novice user measuring higher values than the intermediate and expert users. This pattern likely reflects the combined effects of tissue thickness, local flatness, and sensitivity to compression/alignment errors. Expert users likely reduce variability by applying more consistent contact force, maintaining better jaw/probe alignment, selecting more reproducible contact sites, and avoiding oblique placement or over-compression. Untrained users are more likely to compress the specimen, misalign the device, or choose slightly different local regions, which becomes particularly important in thin, compliant vessels. These interpretations are directly supported by the observed reduction in variability with increasing experience and by the gauge’s lower operator dependence.
Our findings demonstrate that while both instruments are capable of producing measurements within an acceptable range for gross anatomical assessment, depending on the protocol applied, the digital thickness gauge exhibited superior repeatability and reduced operator-dependent variability, especially when tissue thickness was small. These differences have important practical implications for laboratories conducting ex vivo vascular characterization, where consistency and reproducibility are essential for minimizing methodological noise and improving statistical power in mechanical testing datasets (Cardiovascular Solid Mechanics, 2025; Holzapfel and Ogden, 2003; Fung, 1993).
The superior performance of the digital thickness gauge aligns with previous studies emphasizing the importance of consistent contact pressure and stable probe alignment when measuring compliant biological tissues (Silver et al., 2001; Carew et al., 1968; Holzapfel et al., 2012). The gauge’s spring-loaded mechanism appears to facilitate more uniform force application, thereby mitigating tissue compression artifacts—a known source of systematic error when using calipers on soft tissues (Nielsen et al., 1991; Vorp et al., 2003). In contrast, the Vernier caliper, designed primarily for rigid materials, requires the operator to actively control the applied force, making it more susceptible to inter- and intra-user variability, particularly with thin arterial specimens (Corporation, 2019).
Another key observation was that the digital thickness gauge reduced measurement time, thereby improving the overall efficiency of biomechanical analysis workflows. Measurement efficiency is especially relevant in ex vivo vascular testing, where numerous samples must be processed rapidly to prevent tissue dehydration, viscoelastic relaxation, enzymatic degradation, or temperature-related changes in mechanical response (O’Rourke et al., 2002; Sommer et al., 2010). Faster, standardized measurement protocols may therefore indirectly improve data quality by limiting exposure to time-dependent confounding factors.
An additional consideration is the influence of tissue handling technique. While the thickness gauge reduced operator dependence, residual variability may still arise from differences in tissue hydration, sample orientation, axial stretch, and preconditioning history—factors that are well documented to affect vascular mechanical behavior and apparent wall thickness (Sacks and Sun, 2003).
These findings are consistent with recent studies on vascular tissue measurement, particularly those using porcine venous and arterial specimens. In that work, the digital thickness gauge (Mitutoyo 547-500S) demonstrated superior consistency, with repeated measurements showing no significant differences across three consecutive trials (p = 0.953, p = 0.742, and p = 0.897) and minimal variability regardless of examiner experience. In contrast, Vernier caliper protocols—especially those involving multi-point or bilateral measurements—produced statistically significant differences between sequential measurements (often p < 0.05) and systematically underestimated initial thickness values relative to subsequent readings [30]. Such discrepancies can introduce errors of approximately 10%–15% in arterial wall thickness estimation, potentially leading to misleading interpretations of arterial stiffness, stress distribution, and failure properties (Vorp et al., 2003; Raghavan et al., 1996).
From a user-experience perspective, the results strongly favored the digital thickness gauge. Its ergonomic design, fixed contact-pressure control, and one-handed operation reduced reliance on operator skill and training, thereby minimizing measurement variability and improving reproducibility across laboratories. By contrast, Vernier calipers require careful alignment, bilateral contact control, and visual verification, increasing the likelihood of misalignment and misinterpretation—particularly when measuring thin, deformable vascular tissues (Corporation, 2019).
Accurate wall thickness measurement is critical for computing biomechanical parameters such as Cauchy stress, circumferential strain, and Young’s modulus derived from tensile or inflation-extension testing. Even modest inaccuracies in thickness measurement can significantly distort stress–strain curves and bias biomechanical interpretation (Humphrey and Holzapfel, 2012; Sokolis, 2007; S and hadwick, 1999). Employing a thickness gauge, therefore, improves internal validity and reduces error propagation in biomechanical models that depend on precise geometric inputs.
Our results mirror prior findings in soft-tissue metrology, where compliant tissues are more reliably measured using thickness gauges or controlled-force micrometers, whereas heterogeneous or porous tissues (e.g., aneurysmal intraluminal thrombus) may require alternative approaches, including imaging-based or sectioning methods (Vorp et al., 2003; Di Martino et al., 2006). Moreover, extensive literature on arterial intima–media thickness assessment via ultrasound highlights the importance of reproducible, standardized measurement protocols and reduced operator bias, further reinforcing the value of consistency over manual estimation (Stein et al., 2008; Touboul et al., 2012; Bots et al., 1997).
However, both instruments demonstrate inherent limitations. Neither device provides real-time, in situ wall thickness measurements comparable to those obtained with high-resolution imaging modalities such as ultrasound, optical coherence tomography (OCT), or micro–computed tomography (micro-CT). Although these techniques offer superior spatial resolution and eliminate direct tissue manipulation, they remain costly, technically demanding, and less accessible for many experimental biomechanics laboratories (Chiu et al., 2008; Rezakhaniha et al., 2012; Łagan and Liber-Kneć, 2020). Within this context, the digital thickness gauge represents a practical compromise between affordability, ease of use, and measurement reliability.
This study utilized porcine arterial specimens at room temperature under ex vivo conditions. Extrapolation to in vivo human arteries must therefore consider physiological factors such as smooth muscle tone, pulsatile loading, blood pressure–dependent deformation, and temperature effects on tissue compliance (Vlachopoulos et al., 2011; Humphrey and Delange, 2004; Laurent et al., 2006). Future studies correlating caliper- and gauge-based measurements with imaging modalities such as high-resolution ultrasound or OCT would further validate measurement accuracy and clinical relevance. Additionally, systematic evaluation of contact-force calibration, tissue stiffening, and ambient humidity effects would help refine standardized protocols for vascular thickness measurement.
Although protocol-dependent differences in thickness measurements were observed, particularly in thinner vessels and among less experienced users, these variations did not translate into statistically significant differences in derived biomechanical parameters. This is likely because the magnitude of thickness variation was relatively small compared with the inherent variability in force–displacement response between specimens. As a result, the influence of geometric measurement differences on calculated stress and stiffness was limited under the present experimental conditions.
To place the present findings in context, it is essential to acknowledge the substantial methodological variability across studies in both biomechanical testing and arterial wall thickness measurement (Dwivedi et al., 2023; Pukaluk et al., 2022; de Beaufort et al., 2018; Bechsgaard et al., 2018; Arbănaşi et al., 2024; Peña et al., 2022; Mureşan et al., 2024). Prior investigations of porcine arterial tissues, including those conducted by Sachin Kumar’s group (Dwivedi et al., 2023), have frequently utilized multiaxial bulge or inflation testing to better approximate physiologically relevant loading conditions. Such approaches enable robust characterization of biaxial stress–strain behavior as well as spatial heterogeneity within the vessel wall (Dwivedi et al., 2023). In contrast, a large proportion of the literature relies on uniaxial tensile testing of arterial strips with constitutive models applied to capture the nonlinear mechanical response (Arbănaşi et al., 2024). Although widely adopted due to experimental simplicity, uniaxial testing does not fully represent the coupled, anisotropic behavior of vascular tissues and may introduce directional bias in stiffness estimates (Pukaluk et al., 2022; de Beaufort et al., 2018; Bechsgaard et al., 2018). Equally important, yet often underappreciated, is the lack of standardization in thickness measurement protocols, which represents a significant source of variability. For instance, some studies employ digital micrometers with controlled contact forces to limit tissue compression and enhance measurement reproducibility (Ion et al., 2024a; Ion et al., 2024b), whereas others rely on manual measurements obtained during specimen preparation with a digital caliper (Arbănaşi et al., 2024; Mureşan et al., 2024). Taken together, these methodological disparities suggest that reported differences in stress and stiffness across studies may not solely reflect biological variability but are also influenced by experimental design—particularly the choice of loading configuration and, critically, the approach used to quantify wall thickness (Famaey et al., 2026). An additional potential source of bias arises from variability in specimen storage conditions prior to mechanical testing (Arbănaşi and Chirilă, 2026; Alloisio et al., 2024; Lin et al., 2022; Eliathamby et al., 2022; Peterson et al., 2025). In most experimental protocols, tissues are stored for short-to mid-term periods under controlled conditions before analysis, which may inadvertently influence their structural and mechanical properties (Arbănaşi and Chirilă, 2026; Alloisio et al., 2024). Conversely, some groups advocate the use of freshly harvested specimens—typically tested within 4 h (Eliathamby et al., 2022) to 24 h (Peterson et al., 2025) — to minimize storage-induced alterations and better preserve native biomechanical behavior. This lack of consensus in handling protocols further underscores the challenges in comparing results across studies and highlights the need for standardized preservation and testing procedures.
As a practical guideline, compliant soft tissues with millimeter-scale thickness should preferentially be measured using a digital thickness gauge with controlled contact force, particularly when specimens are thin, highly deformable, or evaluated by multiple operators. When a digital vernier caliper is employed, measurement variability should be minimized through strict standardization, including use of a single trained operator, adherence to a predefined multi-point measurement protocol, maintenance of perpendicular jaw alignment, application of minimal compressive force, and preservation of continuous specimen hydration.
The present study has several limitations that warrant consideration. First, our experimental investigation included twelve specimens for each type of porcine arterial tissue. Although the observed measurement biases in wall thickness did not ultimately influence the derived biomechanical properties, the relatively small sample size and the considerable data variability should be considered when interpreting the results. Based on our findings, we recommend that users employ a digital thickness gauge to enhance measurement reproducibility and consistency. However, if a digital vernier caliper is used, measurements should be performed by a highly experienced operator. Secondly, our analysis was restricted to healthy and uniform porcine vascular tissue. Future studies should evaluate both measurement devices using normal and pathological human arterial tissues to corroborate and extend the conclusions of the current work. Third, the study lacked an independent gold-standard reference for arterial wall thickness measurement. Although reproducibility and inter-protocol agreement were assessed, absolute measurement accuracy could not be definitively established. Other limitations include potential tissue-compression artifacts, which are inherent to both instruments tested. Thus, the results of the current study should not be directly extrapolated to small-animal vessels, such as mouse or rat aorta, whose wall thickness is in the micrometer range. In such settings, contact-based caliper or gauge measurements may be limited by probe size, device resolution, and tissue compression. While the digital thickness gauge employs a spring-loaded mechanism designed to standardize contact force, some degree of tissue deformation is unavoidable when measuring compliant biological materials. This effect may be particularly pronounced in thinner vessels such as coronary arteries, potentially leading to systematic underestimation of wall thickness and influencing derived biomechanical parameters. A principal limitation of this study concerns the statistical treatment of repeated measurements. As identical specimens were evaluated across multiple protocols and operators, the resulting observations are inherently non-independent. However, for analytical simplicity and to maintain comparability across protocols and users within a unified framework, the data were modeled as independent groups rather than employing a repeated-measures or mixed-effects approach. While this strategy facilitated straightforward group-wise comparisons, it does not account for within-specimen correlations and may have led to an underestimation of variability, thereby influencing the risk of both type I and type II errors. Accordingly, the absence of statistically significant differences in the assessed biomechanical parameters should not be interpreted as evidence of equivalence between measurement methods, but rather as a lack of detectable differences within the constraints of the applied analytical framework. Future studies using larger sample sizes and mixed-effects modeling approaches may further refine these findings.
5. Conclusion
In conclusion, this study demonstrates that the method used to measure arterial wall thickness influences measurement reproducibility, particularly for thin-walled vessels such as coronary arteries and when measurements are performed by less experienced users. Operator experience significantly reduced variability when using a digital vernier caliper, whereas the dedicated digital thickness gauge provided more consistent and user-independent measurements across all vessel types and experience levels. Nevertheless, to minimize methodological noise, reduce operator bias, and improve reproducibility—especially in small or highly compliant vessels—we recommend a digital thickness gauge as the preferred tool for arterial wall thickness determination in ex vivo biomechanical studies. These findings should be interpreted in the context of the study design and its statistical limitations, particularly regarding the handling of repeated measurements.
Acknowledgements
All determinations were performed in the Regenerative Medicine Laboratory at the Center for Advanced Medical and Pharmaceutical Research (CCAMF) in Târgu Mureș, Romania. This article is part of a PhD thesis from the Doctoral School of Medicine and Pharmacy within the University of Medicine, Pharmacy, Science, and Technology “George Emil Palade” of Târgu Mureş. The thesis will be presented by CC.C. in 2027. All authors have agreed to this acknowledgment.
Funding Statement
The author(s) declared that financial support was received for this work and/or its publication. This work was supported by the George Emil Palade University of Medicine, Pharmacy, Science and Technology of Târgu Mureș, Romania, based on the research grant number 171/2/09.01.2024.
Footnotes
Edited by: Jiaqiu Wang, London South Bank University, United Kingdom
Reviewed by: Krashn Kumar Dwivedi, Washington University in St. Louis, United States
Qiwei Li, China Jiliang University, China
Data availability statement
The raw data supporting the conclusions of this article will be made available by the authors, without undue reservation.
Ethics statement
The requirement of ethical approval was waived by Medical Ethics Committee for the Clinical Study of the Drug within the framework of the Târgu-Mureș County Emergency Clinical Hospital, Romania, decision no. 20239/27.08.2024; approval date: 27 August 2024 for the studies involving animals because In the present study, formal approval from an animal ethics committee was waived because all biological material used was obtained from animals already slaughtered for commercial food production and not specifically for research purposes. The porcine aorta, carotid, and coronary arteries were collected post-mortem from a local slaughterhouse, where the animals were euthanized in accordance with national regulations governing food industry practices and animal welfare. No live animals were housed, handled, subjected to experimental procedures, or sacrificed for the purposes of this research. The study therefore did not involve any direct intervention, manipulation, or experimentation on living animals, nor did it influence the conditions of slaughter. The use of discarded tissues that would otherwise have been treated as waste aligns with commonly accepted ethical standards for ex vivo biomechanical studies and does not require additional animal ethics approval under prevailing regulations. The studies were conducted in accordance with the local legislation and institutional requirements.
Author contributions
CC: Visualization, Formal Analysis, Validation, Data curation, Methodology, Investigation, Writing – original draft. ER: Supervision, Resources, Formal Analysis, Software, Project administration, Conceptualization, Validation, Investigation, Methodology, Writing – review and editing. AlM: Formal Analysis, Investigation, Data curation, Validation, Writing – review and editing, Supervision. AA: Investigation, Writing – review and editing, Supervision, Validation, Data curation. AI: Conceptualization, Validation, Data curation, Writing – original draft, Investigation. RB: Writing – review and editing, Investigation, Data curation, Validation, Methodology, Formal Analysis. El-MA: Funding acquisition, Project administration, Validation, Data curation, Software, Conceptualization, Writing – original draft. AM: Formal Analysis, Writing – review and editing, Methodology, Validation, Funding acquisition, Visualization, Resources. CR: Data curation, Writing – review and editing, Supervision, Funding acquisition, Validation, Visualization, Project administration. TH: Methodology, Data curation, Investigation, Validation, Writing – original draft. TC: Visualization, Validation, Project administration, Resources, Data curation, Supervision, Investigation, Writing – review and editing. SV: Visualization, Project administration, Software, Methodology, Investigation, Validation, Resources, Writing – review and editing, Supervision. Em-MA: Investigation, Resources, Conceptualization, Funding acquisition, Writing – review and editing, Writing – original draft, Project administration, Data curation, Validation, Methodology, Visualization, Supervision.
Conflict of interest
The author(s) declared that this work was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.
The author TC declared that they were an editorial board member of Frontiers at the time of submission. This had no impact on the peer review process and the final decision.
Generative AI statement
The author(s) declared that generative AI was not used in the creation of this manuscript.
Any alternative text (alt text) provided alongside figures in this article has been generated by Frontiers with the support of artificial intelligence and reasonable efforts have been made to ensure accuracy, including review by the authors wherever possible. If you identify any issues, please contact us.
Publisher’s note
All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.
Supplementary material
The Supplementary Material for this article can be found online at: https://www.frontiersin.org/articles/10.3389/fbioe.2026.1791599/full#supplementary-material
References
- Alloisio M., Wolffs J. J. M., Gasser T. C. (2024). Specimen width affects vascular tissue integrity for in-vitro characterisation. J. Mech. Behav. Biomed. Mater 154, 106520. 10.1016/j.jmbbm.2024.106520 [DOI] [PubMed] [Google Scholar]
- Arbănaşi E. M., Chirilă T. V. (2026). Preservation of human vascular tissue and the relevance of temperature: a narrative review. Front. Bioeng. Biotechnol. 13, 1631214. 10.3389/fbioe.2025.1631214 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Arbănaşi E. M., Russu E., Arbănaşi E. M., Ciucanu C. C., Mureşan A. V., Suzuki S., et al. (2024). Effect of ultraviolet radiation on the enzymolytic and biomechanical profiles of abdominal aortic adventitia tissue. J. Clin. Med. 13 (2), 633. 10.3390/jcm13020633 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Bechsgaard T., Lindskow T., Lading T., Hasenkam J. M., Røpcke D. M., Nygaard H., et al. (2018). Biomechanical characterization of the native porcine aortic root. J. Biomech. 74, 156–162. 10.1016/j.jbiomech.2018.04.037 [DOI] [PubMed] [Google Scholar]
- Bots M. L., Hoes A. W., Koudstaal P. J., Hofman A., Grobbee D. E. (1997). Common carotid intima-media thickness and risk of stroke and myocardial infarction: the rotterdam study. Circulation 96, 1432–1437. 10.1161/01.cir.96.5.1432 [DOI] [PubMed] [Google Scholar]
- Cardiovascular Solid Mechanics (2025). Cardiovascular solid mechanics: cells, tissues, and organs. Springer, New York: ResearchGate; 10.1115/1.1497492 [DOI] [Google Scholar]
- Carew T. E., Vaishnav R. N., Patel D. J. (1968). Compressibility of the arterial wall. Circ. Res. 23, 61–68. 10.1161/01.res.23.1.61 [DOI] [PubMed] [Google Scholar]
- Chiu B., Egger M., Spence J. D., Parraga G., Fenster A. (2008). Quantification of carotid vessel wall and plaque thickness change using 3D ultrasound images. Med. Phys. 35, 3691–3710. 10.1118/1.2955550 [DOI] [PubMed] [Google Scholar]
- Corporation M. (2019). Metrology handbook: thickness measurement techniques. Kawasaki Mitutoyo. [Google Scholar]
- de Beaufort H. W. L., Ferrara A., Conti M., Moll F. L., van Herwaarden J. A., Figueroa C. A., et al. (2018). Comparative analysis of porcine and human thoracic aortic stiffness. Eur. J. Vasc. Endovasc. Surg. 55 (4), 560–566. 10.1016/j.ejvs.2017.12.014 [DOI] [PubMed] [Google Scholar]
- de Gelidi S., Tozzi G., Bucchi A. (2017). The effect of thickness measurement on numerical arterial models. Mater Sci. Eng. C Mater Biol. Appl. 76, 1205–1215. 10.1016/j.msec.2017.02.123 [DOI] [PubMed] [Google Scholar]
- Di Martino E. S., Bohra A., Vande Geest J. P., Gupta N., Makaroun M. S., Vorp D. A. (2006). Biomechanical properties of ruptured versus electively repaired abdominal aortic aneurysm wall tissue. J. Vasc. Surg. 43, 570–576. 10.1016/j.jvs.2005.10.072 [DOI] [PubMed] [Google Scholar]
- Dwivedi K. K., Lakhani P., Yadav A., Deepak K. S., Kumar N. (2023). Location specific multi-scale characterization and constitutive modeling of pig aorta. J. Mech. Behav. Biomed. Mater 142, 105809. 10.1016/j.jmbbm.2023.105809 [DOI] [PubMed] [Google Scholar]
- Eliathamby D., Keshishi M., Ouzounian M., Forbes T. L., Tan K., Simmons C. A., et al. (2022). Ascending aortic geometry and its relationship to the biomechanical properties of aortic tissue. JTCVS Open 13, 32–44. 10.1016/j.xjon.2022.08.015 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Famaey N., Fehervary H., Lafon Y., Akyildiz A., Dreesen S., Bruyère-Garnier K., et al. (2026). Community challenge towards consensus on characterization of biological tissue: C4Bio's first findings. J. Biomech. 194, 113021. 10.1016/j.jbiomech.2025.113021 [DOI] [PubMed] [Google Scholar]
- Fung Y.-C. (1993). Biomechanics: mechanical properties of living tissues 2nd ed. New York, NY: Springer. 10.1007/978-1-4757-2257-4 [DOI] [Google Scholar]
- Holzapfel G., Ogden R. (2003). Biomechanics of soft tissue in cardiovascular systems. 10.1007/978-3-7091-2736-0 [DOI] [Google Scholar]
- Holzapfel G. A., Sommer G., Regitnig P. (2004). Anisotropic mechanical properties of tissue components in human atherosclerotic plaques. J. Biomech. Eng. 126, 657–665. 10.1115/1.1800557 [DOI] [PubMed] [Google Scholar]
- Holzapfel G., Gasser T., Ogden R. (2012). A new constitutive framework for arterial wall mechanics and a comparative study of material models. J. Elast. 61, 1–48. 10.1023/A:1010835316564 [DOI] [Google Scholar]
- Hooglugt A., Klatt O., Huveneers S. (2022). Vascular stiffening and endothelial dysfunction in atherosclerosis. Curr. Opin. Lipidol. 33, 353–363. 10.1097/MOL.0000000000000852 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Humphrey J. D., Delange S. L. (2004). An introduction to biomechanics. New York, NY: Springer. 10.1007/978-1-4899-0325-9 [DOI] [Google Scholar]
- Humphrey J. D., Holzapfel G. A. (2012). Mechanics, mechanobiology, and modeling of human abdominal aorta and aneurysms. J. Biomech. 45, 805–814. 10.1016/j.jbiomech.2011.11.021 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Ion A. P., Asztalos A., Ciucanu C. C., Russu E., Muresan A. V., Arbănaşi E.-M., et al. (2024a). Superior measurement accuracy of digital thickness gauge versus digital vernier caliper in determining venous tissue thickness. Cureus 16, e68442. 10.7759/cureus.68442 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Ion A. P., Asztalos A., Ciucanu C. C., Russu E., Mureşan A. V., Arbănaşi E.-M., et al. (2024b). Optimizing arterial tissue thickness measurement protocols: digital vernier caliper versus digital thickness gauge. Methods Protoc. 7, 7. 10.3390/mps7060090 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Łagan S., Liber-Kneć A. (2020). Mechanical properties of porcine aorta – influence of specimen taken orientation, 279–287. 10.1007/978-3-030-29885-2_25 [DOI] [Google Scholar]
- Laurent S., Cockcroft J., Van Bortel L., Boutouyrie P., Giannattasio C., Hayoz D., et al. (2006). Expert consensus document on arterial stiffness: methodological issues and clinical applications. Eur. Heart J. 27, 2588–2605. 10.1093/eurheartj/ehl254 [DOI] [PubMed] [Google Scholar]
- Li Y., Cao G.-Y., Jing W.-Z., Liu J., Liu M. (2023). Global trends and regional differences in incidence and mortality of cardiovascular disease, 1990-2019: findings from 2019 global burden of disease study. Eur. J. Prev. Cardiol. 30, 276–286. 10.1093/eurjpc/zwac285 [DOI] [PubMed] [Google Scholar]
- Lin S., Morgant M. C., Marín-Castrillón D. M., Walker P. M., Aho Glélé L. S., Boucher A., et al. (2022). Aortic local biomechanical properties in ascending aortic aneurysms. Acta Biomater. 149, 40–50. 10.1016/j.actbio.2022.06.019 [DOI] [PubMed] [Google Scholar]
- Lisický O., Hrubanová A., Staffa R., Vlachovský R., Burša J. (2021). Constitutive models and failure properties of fibrous tissues of carotid artery atheroma based on their uniaxial testing. J. Biomech. 129, 110861. 10.1016/j.jbiomech.2021.110861 [DOI] [PubMed] [Google Scholar]
- Mureşan A. V., Arbănaşi E. M., Russu E., Kaller R., Ciucanu C. C., Ion A. P., et al. (2024). The role of the mechanical characteristics and microstructure of the porcine aortic wall: implications for abdominal aortic aneurysm rupture risk. J. Cardiovasc. Emergencies 10 (1), 13–19. 10.2478/jce-2024-0007 [DOI] [Google Scholar]
- Nielsen P. M., Hunter P. J., Smaill B. H. (1991). Biaxial testing of membrane biomaterials: testing equipment and procedures. J. Biomech. Eng. 113, 295–300. 10.1115/1.2894887 [DOI] [PubMed] [Google Scholar]
- O’Leary S. A., Doyle B. J., McGloughlin T. M. (2013). Comparison of methods used to measure the thickness of soft tissues and their influence on the evaluation of tensile stress. J. Biomech. 46, 1955–1960. 10.1016/j.jbiomech.2013.05.003 [DOI] [PubMed] [Google Scholar]
- O’Rourke M. F., Staessen J. A., Vlachopoulos C., Duprez D., Plante G. E. (2002). Clinical applications of arterial stiffness; definitions and reference values. Am. J. Hypertens. 15, 426–444. 10.1016/s0895-7061(01)02319-6 [DOI] [PubMed] [Google Scholar]
- Peña J. A., Cilla M., Martínez M. A., Peña E. (2022). Biomechanical characterization and constitutive modeling of the layer-dissected residual strains and mechanical properties of abdominal porcine aorta. J. Biomech. 132, 110909. 10.1016/j.jbiomech.2021.110909 [DOI] [PubMed] [Google Scholar]
- Peterson S., Eliathamby D., Yap H., Elbatarny M., Guruji V., Islam R., et al. (2025). Differences in biomechanical properties of the ascending aorta in aneurysmal and normal aortas. Biomech. Model. Mechanobiol. 24 (3), 865–877. 10.1007/s10237-025-01941-y [DOI] [PubMed] [Google Scholar]
- Pukaluk A., Wolinski H., Viertler C., Regitnig P., Holzapfel G. A., Sommer G. (2022). Changes in the microstructure of the human aortic medial layer under biaxial loading investigated by multi-photon microscopy. Acta Biomater. 151, 396–413. 10.1016/j.actbio.2022.08.017 [DOI] [PubMed] [Google Scholar]
- Raghavan M. L., Webster M. W., Vorp D. A. (1996). Ex vivo biomechanical behavior of abdominal aortic aneurysm: assessment using a new mathematical model. Ann. Biomed. Eng. 24, 573–582. 10.1007/BF02684226 [DOI] [PubMed] [Google Scholar]
- Rezakhaniha R., Agianniotis A., Schrauwen J. T. C., Griffa A., Sage D., Bouten C. V. C., et al. (2012). Experimental investigation of collagen waviness and orientation in the arterial adventitia using confocal laser scanning microscopy. Biomech. Model. Mechanobiol. 11, 461–473. 10.1007/s10237-011-0325-z [DOI] [PubMed] [Google Scholar]
- Shadwick R. E. (1999). Mechanical design in arteries. J. Exp. Biol. 202, 3305–3313. 10.1242/jeb.202.23.3305 [DOI] [PubMed] [Google Scholar]
- Sacks M. S., Sun W. (2003). Multiaxial mechanical behavior of biological materials. Annu. Rev. Biomed. Eng. 5, 251–284. 10.1146/annurev.bioeng.5.011303.120714 [DOI] [PubMed] [Google Scholar]
- Santos R., Castro R., Baeza R., Nunes F., Filipe V. M., Renna F., et al. (2025). Segmentation of coronary calcifications with a domain knowledge-based lightweight 3D convolutional neural network. Comput. Biol. Med. 196, 110798. 10.1016/j.compbiomed.2025.110798 [DOI] [PubMed] [Google Scholar]
- Silver F. H., Freeman J. W., DeVore D. (2001). Viscoelastic properties of human skin and processed dermis. Skin. Res. Technol. 7, 18–23. 10.1034/j.1600-0846.2001.007001018.x [DOI] [PubMed] [Google Scholar]
- Sokolis D. P. (2007). Passive mechanical properties and structure of the aorta: segmental analysis. Acta Physiol. (Oxf) 190, 277–289. 10.1111/j.1748-1716.2006.01661.x [DOI] [PubMed] [Google Scholar]
- Sommer G., Regitnig P., Költringer L., Holzapfel G. A. (2010). Biaxial mechanical properties of intact and layer-dissected human carotid arteries at physiological and supraphysiological loadings. Am. J. Physiol. Heart Circ. Physiol. 298, H898–H912. 10.1152/ajpheart.00378.2009 [DOI] [PubMed] [Google Scholar]
- Stein J. H., Korcarz C. E., Hurst R. T., Lonn E., Kendall C. B. American Society of Echocardiography Carotid Intima-Media Thickness Task Force (2008). Use of carotid ultrasound to identify subclinical vascular disease and evaluate cardiovascular disease risk: a consensus statement from the American society of echocardiography carotid intima-media thickness task force. Endorsed by the society for vascular medicine. J. Am. Soc. Echocardiogr. 21, 189–190. 10.1016/j.echo.2007.11.011 [DOI] [PubMed] [Google Scholar]
- Teo K. K., Rafiq T. (2021). Cardiovascular risk factors and prevention: a perspective from developing countries. Can. J. Cardiol. 37, 733–743. 10.1016/j.cjca.2021.02.009 [DOI] [PubMed] [Google Scholar]
- Touboul P.-J., Hennerici M. G., Meairs S., Adams H., Amarenco P., Bornstein N., et al. (2012). Mannheim carotid intima-media thickness and plaque consensus (2004-2006-2011). An update on behalf of the advisory board of the 3rd, 4th and 5th watching the risk symposia, at the 13th, 15th and 20th European stroke conferences, Mannheim, Germany, 2004, Brussels, Belgium, 2006, and Hamburg, Germany, 2011. Cerebrovasc. Dis. 34, 290–296. 10.1159/000343145 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Vlachopoulos C., O’Rourke M., Nichols W. W. (2011). McDonald’s blood flow in arteries: theoretical, experimental and clinical principles. 6th ed. London: CRC Press, 768. 10.1201/b13568 [DOI] [Google Scholar]
- Vorp D. A., Schiro B. J., Ehrlich M. P., Juvonen T. S., Ergin M. A., Griffith B. P. (2003). Effect of aneurysm on the tensile strength and biomechanical behavior of the ascending thoracic aorta. Ann. Thorac. Surg. 75, 1210–1214. 10.1016/s0003-4975(02)04711-2 [DOI] [PubMed] [Google Scholar]
- Wang Z., Zhang W., Xie C., Wen F., Ma C., Lin N., et al. (2019). Geometric anisotropy on biomaterials surface for vascular scaffold design: engineering and biological advances. J. Phys. Mater. 2, 032003. 10.1088/2515-7639/ab1c68 [DOI] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Supplementary Materials
Data Availability Statement
The raw data supporting the conclusions of this article will be made available by the authors, without undue reservation.