Skip to main content
Annals of Surgery logoLink to Annals of Surgery
. 1982 Jan;195(1):55–59. doi: 10.1097/00000658-198201001-00009

A comparison of the effect of pH on the biodegradation of two synthetic absorbable sutures.

C C Chu
PMCID: PMC1352404  PMID: 6275809

Abstract

The differences in hydrolytic degradation of two size 2-0 synthetic absorbable sutures, Polyglycolic acid (Dexon) and Poly(glycolide-lactide) (Vicryl), in the buffer media of three different pH levels ranging from 5.25 to 10.09, were compared in terms of the percentage retention of tensile strength. It was found that Vicryl sutures, in general, exhibited better retention of tensile strength than Dexon sutures within the studied pH range and extent of hydrolysis. When comparing Vicryl with Dexon sutures, the former was only slightly better than Dexon sutures, in the case of an acid environment. The former, however, retained better strength than the latter in a physiological pH (7.44) and under high-alkaline conditions (10.09). Among the three pH levels tested, Vicryl sutures retained the highest tensile strength in a physiological pH and showed a faster loss of tensile strength in both acidic and high-alkaline conditions. Dexon sutures, however, exhibited better retention of tensile strength in the acidic medium than in an alkaline medium. This pH dependent hydrolysis of Dexon and Vicryl sutures should command surgeons' attention in their selection of synthetic absorbable suture materials for particular needs.

Full text

PDF
56

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Bergman F. O., Borgström S. J., Holmlund D. E. Synthetic absorbable surgical suture material (PGA). An experimental study. Acta Chir Scand. 1971;137(3):193–200. [PubMed] [Google Scholar]
  2. Brannan W., Ochsner M. G., Pond H. S., 3rd, Fuselier H. A., Jr, Scharfenberg J. C. Laboratory and clinical experience with polyglycolic acid suture in urogenital surgery. J Urol. 1973 Nov;110(5):571–573. doi: 10.1016/s0022-5347(17)60283-0. [DOI] [PubMed] [Google Scholar]
  3. Chu C. C. Mechanical properties of suture materials: an important characterization. Ann Surg. 1981 Mar;193(3):365–371. doi: 10.1097/00000658-198103000-00021. [DOI] [PMC free article] [PubMed] [Google Scholar]
  4. Craig P. H., Williams J. A., Davis K. W., Magoun A. D., Levy A. J., Bogdansky S., Jones J. P., Jr A biologic comparison of polyglactin 910 and polyglycolic acid synthetic absorbable sutures. Surg Gynecol Obstet. 1975 Jul;141(1):1–10. [PubMed] [Google Scholar]
  5. Echeverría E., Jiménez J. Evaluation of an absorbable synthetic suture material. Surg Gynecol Obstet. 1970 Jul;131(1):1–14. [PubMed] [Google Scholar]
  6. Herrmann J. B., Kelly R. J., Higgins G. A. Polyglycolic acid sutures. Laboratory and clinical evaluation of a new absorbable suture material. Arch Surg. 1970 Apr;100(4):486–490. doi: 10.1001/archsurg.1970.01340220162027. [DOI] [PubMed] [Google Scholar]
  7. Holm-Jensen S., Agner E. Syntetisk absorberbart suturmateriale (PGA) sammenlignet med catgut. Ugeskr Laeger. 1974 Aug 5;136(32):1785–1790. [PubMed] [Google Scholar]
  8. Kaminski J. M., Katz A. R., Woodward S. C. Urinary bladder calculus formation on sutures in rabbits, cats and dogs. Surg Gynecol Obstet. 1978 Mar;146(3):353–357. [PubMed] [Google Scholar]
  9. Milroy E. An experimental study of the calcification and absorption of polyglycolic acid and catgut sutures within the urinary tract. Invest Urol. 1976 Sep;14(2):141–142. [PubMed] [Google Scholar]
  10. Pavan A., Bosio M., Longo T. A comparative study of poly(glycolic acid) and catgut as suture materials. Histomorphology and mechanical properties. J Biomed Mater Res. 1979 May;13(3):477–496. doi: 10.1002/jbm.820130312. [DOI] [PubMed] [Google Scholar]
  11. Postlethwait R. W. Polyglycolic acid surgical suture. Arch Surg. 1970 Oct;101(4):489–494. doi: 10.1001/archsurg.1970.01340280041011. [DOI] [PubMed] [Google Scholar]
  12. Salthouse T. N., Matlaga B. F. Polyglactin 910 suture absorption and the role of cellular enzymes. Surg Gynecol Obstet. 1976 Apr;142(4):544–550. [PubMed] [Google Scholar]
  13. Williams D. F., Mort E. Enzyme-accelerated hydrolysis of polyglycolic acid. J Bioeng. 1977 Aug;1(3):231–238. [PubMed] [Google Scholar]
  14. Williams D. F. The effect of bacteria on absorbable sutures. J Biomed Mater Res. 1980 May;14(3):329–338. doi: 10.1002/jbm.820140313. [DOI] [PubMed] [Google Scholar]

Articles from Annals of Surgery are provided here courtesy of Lippincott, Williams, and Wilkins

RESOURCES