Skip to main content
Frontiers in Surgery logoLink to Frontiers in Surgery
. 2026 Sep 3;13:1945489. doi: 10.3389/fsurg.2026.1945489

Comparison of ACDF with stand-alone PEEK cage versus zero-p implant for the treatment of cervical degenerative disease: a systematic review and meta-analysis

Yiheng Zhao 1, Juan Xie 2,3,4, Ling Zhu 2,3,4, Jianna Zhang 2,3,4, Junhui Zhang 5,*
PMCID: PMC13583156  PMID: 42756378

Abstract

Introduction

In recent years, stand-alone polyetheretherketone (PEEK) cages (SA) and Zero-P implants (ZP) have been widely adopted clinically in anterior cervical discectomy and fusion (ACDF) for cervical degenerative disease (CDD). However, which is superior between SA and ZP remains highly controversial. This meta-analysis was designed to conduct a head-to-head comparison of the safety, clinical efficacy, and radiological effectiveness of ACDF with ZP and SA.

Methods

This research was carried out in accordance with the PRISMA Statement. Systematic retrieval of eligible literature was completed covering three core electronic bibliographic databases: PubMed, Web of Science Core Collection, and Embase up to February 19, 2026. For dichotomous outcomes, including the fusion rate and subsidence rate, the effect sizes were calculated as the relative risk (RR) with corresponding 95% confidence intervals (CIs). For continuous outcomes, including surgical time, blood loss, disc height, vertebral height, C2-7 Cobb angle, segmental Cobb angle, VAS score, and NDI score, the effect sizes are expressed as the mean difference (MD) with 95% CIs.

Results

Eight eligible studies comparing ACDF with SA and ZP for CDD treatment were ultimately included. The pooled patient cohort consisted of 727 participants in total, with 384 patients assigned to the SA group for ACDF and 343 patients allocated to the ZP group. Compared with the ZP, the SA had a significantly shorter operative time and higher NDI score. The segmental Cobb angle, disc height and vertebral height of the SA were significantly lower than those of the ZP. The SA group had a significantly higher subsidence rate than the ZP group, with no remarkable difference observed in the C2-7 Cobb angle, fusion rate, VAS score between the two cohorts.

Discussion

Current pooled findings suggest that SA may be associated with shorter operative time, while ZP may correlate with lower subsidence rate and better preservation of cervical alignment. As all available evidence is derived exclusively from observational studies and rated as low to very low certainty, the conclusions must be interpreted with caution.

Clinical Trial Registration: https://www.crd.york.ac.uk/PROSPERO/view/CRD420261325943, PROSPERO, CRD420261325943.

Keywords: anterior cervical discectomy and fusion, cervical degenerative disease, meta-analysis, stand-alone peek cage, systematic review, zero-P implant

1. Introduction

Since Smith and Robinson (1) first proposed the use of anterior cervical discectomy and fusion (ACDF) for the treatment of cervical degenerative disease (CDD) in 1958, ACDF has long been regarded as the gold standard for treating CDD. Despite more than 60 years having passed, ACDF remains recognized as a classic surgical procedure for CDD. Anterior cervical plates have been widely used in ACDF procedures because of their ability to improve cervical curvature, provide excellent immediate stability, and increase fusion rates (2–4). However, scholars have gradually reported that the use of anterior cervical plates is also associated with a series of complications, including the following postoperative complications: adjacent segment degeneration (ASD), hardware-related adverse events (screw loosening and fracture), prevertebral soft tissue irritation and iatrogenic injury, and postoperative dysphagia (5–8).

To avoid a series of complications caused by anterior cervical plates, the use of anterior cervical plating has gradually been abandoned in clinical practice. In recent years, stand-alone polyetheretherketone (PEEK) cages (SA) and Zero-P implants (ZP) have been widely adopted clinically (9–12). Because they are contained within the intervertebral space and do not protrude beyond the vertebral body surface, they can reduce irritation to the anterior cervical soft tissues and lower the incidence of dysphagia (13, 14). SA can restore intervertebral height, improve cervical lordosis, and facilitate interbody fusion (15, 16). However, some studies have reported risks, including cage migration, subsidence, and the need for reoperation (17). Moreover, owing to the integrated plate and screws placed within the intervertebral space, ZP can improve immediate postoperative stability, with favorable clinical outcomes and satisfactory safety (18). Nevertheless, some studies have reported issues such as a higher subsidence rate than with anterior cervical plating (19) and failure to effectively maintain cervical curvature in the treatment of multilevel cervical spondylosis (20, 21).

Both stand-alone PEEK cages and Zero-P implants are commonly used in current ACDF surgery. However, which is superior between SA and ZP remains highly controversial. Few meta-analyses directly compare the safety and clinical and radiological efficacy of SA vs. ZP for the treatment of CDD. This meta-analysis was designed to conduct a head-to-head comparison of the safety, clinical efficacy, and radiological effectiveness of ACDF using ZP and SA.

2. Materials and methods

2.1. Study registration and search strategy

This research was performed in accordance with the PRISMA 2020 Statement (22). It was registered on the PROSPERO platform (CRD420261325943). Systematic retrieval of eligible literature was completed covering three core electronic bibliographic databases: PubMed, Web of Science Core Collection, and Embase, covering all relevant studies published from the establishment of each database up to February 19, 2026. The search strategy combined the following index terms for title or abstract screening: (cervical) AND (standalone OR stand-alone OR stand alone) AND (stand-alone anchored spacer OR anchored cage OR self-lock* OR SAAS OR zero-p OR zero-profile OR no-profile OR anchored spacer). The complete search strategies are presented in Supplementary Table S1. No language restrictions were imposed during the search process. To achieve more comprehensive inclusion of eligible literature, PEEK or polyetheretherketone was not adopt in the search strategy. Instead, whether the cage was made of PEEK by was determined by full-text reading.

2.2. Inclusion and exclusion criteria

This study included comparative research encompassing randomized controlled trials (RCTs) and nonrandomized cohort studies, which primarily aimed to compare the differences in safety, clinical efficacy and radiological findings between SA and ZP for ACDF in patients with CDD. The exclusion criteria included irrelevant studies, review articles, research focusing on adjacent segment disease, comparative studies of SA or ZP with other devices, studies with overlapping patient populations, noncomparative studies, research involving hybrid surgical approaches, conference abstracts, biomechanical studies, and studies where patients were diagnosed with other diseases.

2.3. Data extraction

Relevant data from all included studies were independently extracted by two trained researchers: (1) number of surgeries and bone graft types; (3) age, sex and follow-up period; (4) surgical time and blood loss; (5) disc height, vertebral height, C2-7 Cobb angle and segmental Cobb angle; (6) fusion rate and subsidence rate; and (7) VAS and NDI score.

2.4. Risk of bias assessment

Two reviewers independently applied the Cochrane ROBINS-I tool (23) to evaluate the bias risk of all enrolled non-randomized cohort studies across seven domains: confounding, selection of participants, classification of interventions, deviations from intended interventions, missing data, outcome measurement, and selective reporting. Each domain was categorized into four risk grades: low, moderate, serious, and critical. Any disagreements between the two assessors were resolved by iterative discussion with a third senior author.

2.5. Statistical analysis

All statistical analyses for the present systematic review and meta-analysis were undertaken using the Review Manager software (RevMan version 5.3; Cochrane Collaboration, London, UK). The absolute postoperative values of C2-7 Cobb angle, segmental Cobb angle, vertebral height, disc height, VAS score and NDI score recorded at the final follow-up timepoints were extracted from each included study. For dichotomous outcomes, including the fusion rate and subsidence rate, the effect sizes were calculated as the relative risk (RR) with corresponding 95% confidence intervals (CIs). For continuous outcomes, including surgical time, blood loss, disc height, vertebral height, C2-7 Cobb angle, segmental Cobb angle, VAS score, and NDI score, the effect sizes are expressed as the mean difference (MD) with 95% CIs. For all statistical tests in this meta-analysis, the threshold of statistical significance was set at a two-tailed P value below 0.05. Meanwhile, between-study heterogeneity among the enrolled literature was quantified and evaluated using the I2 statistic (which ranged from 0 to 100%), and an I2 value >50% indicated significant heterogeneity. For all pooled analyses in this meta-analysis, a random-effects model was adopted in the presence of statistically significant between-study heterogeneity; by contrast, a fixed-effects model was selected for data merging when the I2 statistic was less than 50%. Funnel plot was generated to examine the risk of publication bias across included studies when the number of included studies exceeded 10, and additionally performed sequential sensitivity analysis to assess the stability and reliability of our overall pooled outcomes. Meta-regression was conducted to test the stability of the results when the number of enrolled studies exceeded 10. Subgroup analysis was conducted according to the number of surgical levels and number of screws in ZP. Two independent investigators conducted the evidence certainty assessment pursuant to the Grading of Recommendations, Assessment, Development, and Evaluation (GRADE) framework (24).

3. Results

3.1. Identification of relevant studies

A total of 270 studies were initially retrieved through systematic searches of the PubMed, Web of Science core collection and Embase databases. After duplicate records were removed, 125 studies remained for further screening. We subsequently excluded 12 irrelevant studies, 8 review articles, 39 comparative studies of SA or ZP with other surgical devices, 33 noncomparative studies, 5 studies involving hybrid surgical approaches, 6 conference abstracts, 6 biomechanical studies, and 4 studies enrolling patients with other concurrent diseases. One study with potential overlapping patient cohorts was excluded (25), along with 1 study that compared two different types of SA (26). Meanwhile, after re-examining the included studies, we found that Mu et al. (27) and Virkar et al. (28) did not explicitly report cage material. Although their radiographic images suggested PEEK cages, after careful consideration, we could not rule out the possibility that titanium cages might have been included. Consequently, these two studies were excluded. Finally, 8 eligible studies comparing ACDF with SA vs. ZP for the treatment of CDD were included in this study (29–36). The PEEK cage was used across all included studies. The detailed study selection process is presented in Figure 1.

Figure 1.

Flow diagram summarizing a systematic review selection process: out of 270 records identified, 145 duplicates were removed, 12 irrelevant studies excluded, and 97 reports excluded for various reasons. Eight studies were included in the final review.

A flow diagram of study selection.

3.2. Characteristics of the included studies

All the studies ultimately eligible for this meta-analysis were observational cohort studies, including 7 retrospective analyses and 1 prospective cohort investigations. The core baseline features of the included studies, including study design, material of cage, follow-up duration, patient demographic data and surgical intervention details, are systematically summarized in Table 1. The pooled patient cohort consisted of 727 participants in total, with 384 patients assigned to the SA group for ACDF and 343 patients allocated to the ZP group.

Table 1.

Basic information of the included studies.

Study Study design Country Surgical level Material of cage Screw number in ZP Sample size Mean age (y) Gender (M/F) Follow-up (month)
SA ZP SA ZP SA ZP SA ZP
Balakumar (29) RCS UK 1/2/3 PEEK 2-screw 83 79 53.8 ± 10.07 51.16 ± 12.12 38/45 47/32 9.5 ± 5.8 9.08 ± 6.6
Cho (30) RCS Korea 1 PEEK 4-screw 29 21 55.2 ± 10.4 56.1 ± 12.0 19/10 12/9 24
Gerszten (31) RCS USA 3/4 PEEK 3-screw 35 33 52 (42–70) 60 (41–75) 15/8 16/7 >6
Khattab (32) PCS Egypt 1 PEEK 2-screw 21 29 53.2 ± 5.4 54.4 ± 5.3 9/12 10/19 24
Kwon (33) RCS Korea 1 PEEK 4-screw 20 21 52.20 ± 10.37 49.55 ± 9.34 10/10 9/12 12
Lee (34) RCS Korea 1 PEEK 4-screw 60 23 53.62 ± 11.47 57.26 ± 13.28 30/30 11/12 18.98 ± 10.30 12.57 ± 2.09
Mckee (35) RCS UK 1 PEEK 2-screw 116 117 45.0 ± 7.71 46.2 ± 7.79 55/61 58/59 7.2 8.2
Shin (36) RCS Korea 1 PEEK 4-screw 20 20 49.0 ± 11.0 50.0 ± 12.0 12/8 7/13 13.1 ± 1.2 13.2 ± 1.0

RCS, retrospective cohort study; PCS, prospective cohort study; SA, stand-alone; PEEK cage; ZP Zero-P implant; DBM, demineralized bone matrix; NS, not specified.

3.3. Quality assessment

Methodological bias of the 8 cohort studies was appraised via the ROBINS-I instrument. All cohort studies were determined to be at moderate risk of bias. This suggests that these studies presented partial methodological deficiencies, and their conclusions warrant cautious interpretation. The full results of the methodological quality assessment are displayed in Figure 2.

Figure 2.

Risk of bias domains table displaying eight studies listed on the y-axis and seven bias domains plus overall rating on the x-axis. Each cell shows yellow for moderate risk, green for low risk, and no red for serious risk. All studies have mostly moderate risk across most domains, with low risk for some domains, particularly D3 and D4. The key indicates green plus is low, yellow minus is moderate, and red cross is serious. Domains include confounding, selection, classification, deviations, missing data, measurement, and selection of reported results.

Risk of bias assessment of included cohort studies using the ROBINS-I tool.

3.4. Meta-analysis of outcomes

3.4.1. Surgical outcomes

Compared with the ZP group, the SA group had a significantly shorter operative time (MD −2.52, 95%CI −4.79 to −0.24; P = 0.03; I2 = 0%). No significant difference was identified in intraoperative blood loss (MD −10.42, 95%CI −35.20 to −14.36; P = 0.41; I2 = 0%) (Figure 3).

Figure 3.

Forest plot comparing surgical time and intraoperative blood loss between SA and ZP groups using data from Cho 2015 and Khattab 2020, showing mean differences with confidence intervals and heterogeneity statistics.

Comparison of surgical outcomes.

3.4.2. C2-7 cobb angle, segmental cobb angle, disc height and vertebral height

Pooled analysis of radiographic outcomes revealed no significant difference in the C2-7 Cobb angle between the SA cage group and the ZP group (MD: −0.43, 95% CI [−1.29, 0.42], P = 0.32; I2 = 40%; Figure 4). In contrast, the segmental Cobb angle of the SA was significantly smaller than ZP (MD: −2.26, 95% CI [−4.03, −0.49], P = 0.01; I2 = 77%; Figure 4). Additionally, compared with patients who received ZP, patients who received SA had significantly shorter disc heights (MD: −0.84, 95% CI [−1.03, −0.65], P < 0.00001; I2 = 0%; Figure 4) and vertebral heights (MD: −1.86, 95% CI [−3.28, −0.43]; P = 0.01; I2 = 0%; Figure 4).

Figure 4.

Forest plot comparing SA and ZP across four outcomes: C2-C7 Cobb angle, segmental Cobb angle, disc height, and vertebral height. Each subgroup displays studies with mean differences, confidence intervals, and weights, summarized by black diamonds. Some results favor ZP, such as disc height and vertebral height, with statistically significant confidence intervals.

Comparison of cervical alignment.

No statistical difference was identified in C2-7 Cobb angle between the two groups in subgroup analysis of 1-level surgery (MD −1.53, 95%CI −4.23 to 1.18; P = 0.27; I2 = 55%), 2-screw ZP (MD −0.19, 95%CI −0.66 to 0.29; P = 0.44; I2 = 0%), 4-screw ZP (MD −2.81, 95%CI −6.31 to 0.69; P = 0.11; I2 = 31%; Figure 5).

Figure 5.

Forest plot of meta-analysis comparing mean differences in Cobb angle changes between SA and ZP groups across multiple studies and screw levels; each study’s confidence interval, combined subgroup results, and overall effect estimates are shown.

Subgroup analysis of C2-7 Cobb angle and segmental cobb angle according to number of surgical level and screws in ZP.

No statistical difference was identified in segmental Cobb angle between the two groups in subgroup analysis of 4-screw ZP (MD −2.40, 95%CI −5.62 to 0.82; P = 0.14; I2 = 81%; Figure 5).

3.4.3. Clinical outcomes

Pooled analysis of patient-reported outcomes revealed no statistically significant between-group differences in neck pain VAS score (MD: 0.36, 95% CI [−1.24, 1.97], P = 0.66, I2 = 91%, Figure 6) and arm pain VAS score (MD: 0.22, 95% CI [−0.37, 0.80], P = 0.47, I2 = 53%, Figure 6). The NDI score in SA was significantly higher than that in ZP group (MD: 2.56, 95% CI [1.52, 3.61], P < 0.00001, I2 = 0%, Figure 6).

Figure 6.

Forest plot comparing SA and ZP groups across three outcomes: VAS for neck, VAS for arm, and NDI. Data from Cho 2015 and Khattab 2020 are summarized with mean differences and confidence intervals, showing heterogeneity and overall effects for each outcome. Each study is represented with a green square and horizontal line, and pooled results are depicted as diamond shapes on the plot, with interpretation axes indicating favor towards SA or ZP.

Comparison of clinical outcomes.

3.4.4. Fusion rate and subsidence rate

The criteria of subsidence and fusion was inconsistent. Regarding cage subsidence, different literatures adopted inconsistent cut-off thresholds: a reduction in intervertebral disc height of more than 2 mm or 3 mm relative to the immediate postoperative measurement was defined as subsidence in separate studies. In terms of bone fusion assessment, heterogeneous criteria were utilized among trials, including the Bridwell grading system, absence of prominent radiolucent zones surrounding the cage, presence of continuous trabecular bone bridging between vertebral endplates, and differences in interspinous motion measured on flexion-extension radiographs.

Pooled analysis revealed no significant difference in the fusion rate (RR: 1.02, 95% CI [0.94, 1.10], P = 0.70; I2 = 0%; Figure 7). In contrast, the rate of implant subsidence was significantly greater in SA than ZP (RR: 1.55, 95% CI [1.12, 2.15], P = 0.008; I2 = 42%; Figure 7).

Figure 7.

Forest plot comparing SA and ZP groups across studies for fusion and subsidence rates, displaying risk ratios with confidence intervals for each study, pooled effects, heterogeneity statistics, and weights, with risk ratios centered on one.

Comparison of the fusion rate and subsidence rate.

No statistical difference was identified in subsidence rate between the two groups in subgroup analysis of 1-level surgery (RR: 2.31, 95% CI [0.96, 5.56], P = 0.06; I2 = 53%; Figure 8), multilevel surgery (RR: 1.01, 95% CI [0.63, 1.62], P = 0.98; I2 = 0%; Figure 8), 2-screw ZP (RR: 2.48, 95% CI [0.16, 39.10], P = 0.52; I2 = 74%; Figure 8) and 4-screw ZP (RR: 1.84, 95% CI [0.90, 3.76], P = 0.10; I2 = 43%; Figure 8).

Figure 8.

Forest plot showing risk ratio and confidence intervals for subsidence rate across four subgroups by surgical approach and screw type, with individual study results, subtotal summaries, heterogeneity statistics, and overall effects represented by black diamonds and blue squares.

Subgroup analysis of subsidence rate according to number of surgical level and screws in ZP.

3.5. Publication bias assessment and meta-regression

Funnel plot-based evaluation of publication bias was not conducted, as fewer than 10 eligible studies were available for each individual outcome. Given that the number of included studies for each outcome variable was less than 10, meta-regression analysis was not performed.

3.6. Sensitivity analysis

For the outcome of the segmental Cobb angle, sensitivity analysis revealed that the original significant between-group difference was abolished after excluding the studies by Mckee et al. (35) and Shin et al. (36), indicating the unsatisfactory stability of this pooled result. In contrast, for all the other outcome comparisons, the pooled results remained unchanged with no significant fluctuations, even when each study was sequentially removed from the quantitative synthesis.

For the outcome of subsidence, sensitivity analysis was performed by excluding the two zero-event studies (33, 35). No statistical difference was identified in subsidence rate between the two groups (RR: 1.28, 95% CI [0.92, 1.79], P = 0.15; I2 = 0%; Figure 9).

Figure 9.

Forest plot comparing the risk ratios of four studies, each represented by a blue square and confidence interval line, with an overall pooled risk ratio of 1.28 (ninety-five percent confidence interval 0.92 to 1.79), shown as a diamond, indicating no statistically significant difference between experimental and control groups.

Sensitivity analysis by excluding zero-event studies for subsidence rate.

3.7. Grade of evidence

The grade of the evidence of surgical time, intraoperative blood loss, NDI score, C2-7 Cobb angle, disc height, vertebral height, fusion rate and subsidence rate were considered low and the grade of the evidence of segmental Cobb angle and VAS score were considered very low (Table 2).

Table 2.

GRADE certainty grading evaluation.

Outcomes Certainty assessment Certainty
Number of Studies Study design Risk of bias Inconsistency Indirectness Imprecision Other
Surgical time 2 NRS not serious not serious not serious not serious none ⊕⊕◯◯ Low
Intraoperative blood loss 2 NRS not serious not serious not serious not serious none ⊕⊕◯◯ Low
C2-7 Cobb angle 5 NRS not serious not serious not serious not serious none ⊕⊕◯◯ Low
Segmental Cobb angle 4 NRS not serious high heterogeneity not serious not serious none ⊕◯◯◯ Very low
Disc height 3 NRS not serious not serious not serious not serious none ⊕⊕◯◯ Low
Vertebral height 2 NRS not serious not serious not serious not serious none ⊕⊕◯◯ Low
VAS score 2 NRS not serious high heterogeneity not serious not serious none ⊕◯◯◯ Very low
NDI score 2 NRS not serious not serious not serious not serious none ⊕⊕◯◯ Low
Fusion rate 5 NRS not serious not serious not serious not serious none ⊕⊕◯◯ low
Subsidence rate 6 NRS not serious not serious not serious not serious none ⊕⊕◯◯ low

NRS, Non-randomized study.

4. Discussion

Few meta-analyses directly compare the safety and clinical and radiological efficacy of SA vs. ZP for the treatment of CDD. This study included a total of 2 studies reporting intraoperative blood loss and surgical time (30, 32). However, the pooled results of the meta-analysis in this study revealed that the surgical time of SA were significantly lower than those of ZP. Compared with the ZP, the SA does not require screw placement, with a shorter operation time, and surgical trauma is relatively minor. In contrast, both types of implants have significantly shorter operation times and less intraoperative blood loss than plates and cages do, and both are safe and minimally invasive surgical methods (37–39). The mean operative time differed by only 2.52 min between the SA and ZP groups. Although the differences reached statistical significance, they are of limited clinical relevance.

Only two studies reported the reoperation rate (29, 31). A total of 6 patients underwent reoperation, including 4 patients in the SA group and 2 patients in the ZP group. One patient underwent single-level surgery, and the remaining 5 patients underwent multilevel surgery. There was no statistically significant difference in the reoperation rate between the two groups. These findings indicate that both surgical methods are safe for the treatment of single-level cervical spondylosis. However, for patients who underwent multilevel surgery, reoperations occurred in both groups, and further research is needed regarding the selection of the appropriate surgical strategy.

There are few studies reporting comparisons of VAS and NDI scores between the two implants, with only two included, and they show significant heterogeneity and inconsistent results (30, 32). Cho et al. (30) retrospectively analyzed 50 patients with single-level cervical spondylosis treated with ACDF using ZP (21 patients) or SA (29 patients). They reported no statistically significant differences in neck VAS, arm VAS, or NDI scores between the two groups, and compared with the preoperative values, all the scores significantly improved. Khattab et al. (32) prospectively enrolled 50 patients with single-level cervical spondylosis treated with ACDF using ZP (29 patients) or SA (21 patients). The VAS and NDI scores were significantly greater in the SA group than in the ZP group at the 2-year follow-up. However, this study has certain limitations. The baseline characteristics of the included patients were uneven, and there were statistically significant differences in preoperative arm VAS and NDI scores between the two groups. This may account for the differences in postoperative outcomes and may also contribute to the high heterogeneity in this meta-analysis. Shin et al. (36) retrospectively compared the clinical efficacy of ACDF between the SA group and the ZP group on the basis of Odom's criteria, and no significant difference was detected. However, Lee et al. (34) reported different results. They evaluated clinical outcomes according to Odom's criteria and reported that the clinical efficacy of the SA group was significantly inferior to that of the Zero-P implant group (P = 0.049) and the plate and cage group (P = 0.026), whereas there was no statistically significant difference between the ZP group and the plate and cage group (P = 0.593). There are too few long-term follow-up studies on the improvement of clinical outcomes after SAS and ZP procedures, and further research is still needed.

The segmental Cobb angle, disc height and vertebral height in the SA group were significantly lower than those in the ZP group. The Zero-P implant was a stand-alone anchored cage with a plate and screw integrated into the intervertebral space. Thus, compared with the SA, the ZP was associated with better immediate stability and could better improve cervical alignment (34). Zhang et al. (40, 41) conducted a meta-analysis comparing the radiological efficacy between ZP and anterior plates with cages and reported that ZP and anterior plates with cages resulted in similar results in the maintenance of cervical lordosis in patients with one-level and two-level CDD. Scholz et al. (42) conducted biomechanical tests using C3-7 cadaveric specimens to compare the stability of SA and ZP in two- to three-level ACDF procedures. They reported that the Zero-P implant exhibited significantly better stability than the SA did in terms of flexion-extension, lateral bending, and rotational motion. No significant difference in the C2‒7 Cobb angle was detected between the two groups. However, the ZP tended to be superior to the SA in improving the overall cervical curvature. This may be because most of the included studies were single-level studies, so the overall impact on the cervical spine was minimal. Whether there is an effect on cervical alignment still needs to be confirmed by more high-quality studies.

No significant difference in the fusion rate was detected between the two groups. Achieving fusion is critical to successful ACDF surgery. Mu et al. (27) conducted a retrospective comparison of SA and ZP for two-level CDD, reporting no remarkable between-group difference in fusion rate (SA: 68/76; ZP: 71/78). Successful fusion may also play a crucial role in improving clinical outcomes (43). Elder et al. (44) retrospectively analyzed 22 patients with pseudarthrosis after ACDF and reported that all patients with pseudarthrosis presented with progressively worsening neck pain. After revision surgery, all patients achieved successful fusion, and compared with the preoperative values, the VAS scores significantly improved (p = 0.012).

The subsidence rate in the SA group was significantly greater than that in the ZP group. The immediate stability after SA implantation is inferior to that of the ZP group (42). Owing to the lack of plate and screw support, it is more prone to implant subsidence. The choice of implant used in ACDF surgery has a certain effect on postoperative cervical stability. Tome-Bermejo et al. (45) prospectively collected data from 56 patients who underwent ACCF surgery for cervical spondylosis. After a mean follow-up of 4.85 years, 83% of patients developed implant subsidence, including 7 patients with severe subsidence, which may adversely affect clinical outcomes. Milczynska et al. (46) retrospectively analyzed 39 patients with a total of 64 segments who underwent ACDF using stand-alone titanium cages. They reported that cage subsidence occurred in 9 patients and that there was no statistically significant difference in clinical functional scores between the subsidence group and the non-subsidence group. However, whether implant subsidence affects clinical symptoms remains highly controversial.

4.1. Limitations

Nevertheless, several nonnegligible limitations of the present meta-analysis warrant clarification. First, the overall sample size was relatively limited, with only 8 eligible studies enrolling a total of 727 patients included in the quantitative synthesis. All included studies were nonrandomized studies, leading to a restricted overall level of evidence. Second, the follow-up durations of included studies vary widely, ranging from only 3 months up to 24 months. Heterogeneous radiographic criteria are used to assess subsidence and fusion. The discrepancies in follow-up windows and outcome measurement criteria collectively amplify between-study heterogeneity; accordingly, all pooled radiological effect estimates should be interpreted with caution. Third, the included studies adopted inconsistent screw counts and surgical-level selections. Each subgroup analysis was derived from separate independent studies without formal tests for subgroup interaction. Significant confounding bias also exists between screw number and surgical level. Accordingly, this study cannot confirm that screw number or surgical level represents an independent influencing factor for treatment efficacy. The observed heterogeneity merely reflects baseline characteristics across studies and cannot support causal inference or effect-modifying conclusions. Thus, more high-quality randomized controlled trials are needed to further validate our findings.

5. Conclusion

Current pooled findings suggest that SA may be associated with shorter operative time, while ZP may correlate with lower subsidence rate and better preservation of cervical alignment. As all available evidence is derived exclusively from observational studies and rated as low to very low certainty, the conclusions must be interpreted with caution.

Funding Statement

The author(s) declared that financial support was not received for this work and/or its publication.

Footnotes

Edited by: Mehmet Yigit Akgun, Koç University, Türkiye

Reviewed by: Tobias Greve, Ludwig Maximilian University of Munich, Germany

Marco Battistelli, Agostino Gemelli University Polyclinic (IRCCS), Italy

Data availability statement

The original contributions presented in the study are included in the article/Supplementary Material, further inquiries can be directed to the corresponding author/s.

Author contributions

YZ: Formal analysis, Writing – review & editing, Writing – original draft, Methodology, Conceptualization. JX: Formal analysis, Writing – original draft, Methodology, Conceptualization. LZ: Conceptualization, Formal analysis, Writing – original draft, Methodology. JZ: Formal analysis, Methodology, Writing – original draft, Conceptualization. JZ: Writing – original draft, Conceptualization, Supervision, Writing – review & editing, Methodology, Formal analysis.

Conflict of interest

The author(s) declared that this work was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Generative AI statement

The author(s) declared that generative AI was not used in the creation of this manuscript.

Any alternative text (alt text) provided alongside figures in this article has been generated by Frontiers with the support of artificial intelligence and reasonable efforts have been made to ensure accuracy, including review by the authors wherever possible. If you identify any issues, please contact us.

Publisher's note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

Supplementary material

The Supplementary Material for this article can be found online at: https://www.frontiersin.org/articles/10.3389/fsurg.2026.1945489/full#supplementary-material

Table1.docx (18.8KB, docx)

References

  • 1.Smith GW, Robinson RA. The treatment of certain cervical-spine disorders by anterior removal of the intervertebral disc and interbody fusion. J Bone Joint Surg Am. (1958) 40:607–24. 10.2106/00004623-195840030-00009 [DOI] [PubMed] [Google Scholar]
  • 2.Song KJ, Lee KB. A preliminary study of the use of cage and plating for single-segment fusion in degenerative cervical spine disease. J Clin Neurosci. (2006) 13:181–7. 10.1016/j.jocn.2005.02.018 [DOI] [PubMed] [Google Scholar]
  • 3.Kaiser MG, Haid RW, Subach BR, Barnes B, Rodts GE, Jr., Subach BR. Anterior cervical plating enhances arthrodesis after discectomy and fusion with cortical allograft. Neurosurgery. (2002) 50(2):229–36. 10.1097/00006123-200202000-00001 [DOI] [PubMed] [Google Scholar]
  • 4.Mobbs RJ, Rao P, Chandran NK. Anterior cervical discectomy and fusion: analysis of surgical outcome with and without plating. J Clin Neurosci. (2007) 14(7):639–42. 10.1016/j.jocn.2006.04.003 [DOI] [PubMed] [Google Scholar]
  • 5.Pitzen TR, Chrobok J, Štulik J, Ruffing S, Drumm J, Sova L, et al. Implant complications, fusion, loss of lordosis, and outcome after anterior cervical plating with dynamic or rigid plates: two-year results of a multi-centric, randomized, controlled study. Spine. (2009) 34(7):641–6. 10.1097/BRS.0b013e318198ce10 [DOI] [PubMed] [Google Scholar]
  • 6.Stulik J, Pitzen TR, Chrobok J, Ruffing S, Drumm J, Sova L, et al. Fusion and failure following anterior cervical plating with dynamic or rigid plates: 6-months results of a multi-centric, prospective, randomized, controlled study. Eur Spine J. (2007) 16(10):1689–94. 10.1007/s00586-007-0451-6 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 7.Wang F, Lu J, Wang B, Zhu Z, Shen B, Guo K, et al. Is screw position a greater contributor to adjacent segment disease than plate-to-disc distance following anterior cervical discectomy and fusion? BMC Musculoskelet Disord. (2025) 26(1):297. 10.1186/s12891-025-08285-9 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 8.Gharayba M, Riyad N, Bali B, Maree M, Rabi K, Sawaftah Z, et al. Esophageal perforation following C4-C6 anterior cervical corpectomy with anterior plate fixation: a rare but life-threatening complication requiring surgical repair. Clin Case Rep. (2026) 14(1):e71813. 10.1002/ccr3.71813 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 9.Venkatraman V, Albanese J, Zaidi SE, Than KD, Erickson MM, Crutcher CL, et al. Clinical and radiographic outcomes after index anterior cervical discectomy and fusion with interbody spacer with integrated anchor fixation: a single-surgeon case study. J Spine Surg. (2024) 10(3):416–27. 10.21037/jss-24-32 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 10.Olivares-Camacho JL, Olivares Peña JL, Cuevas-Hernández AA, Hernández-Alcázar EDJ, Jiménez-Ponce F. Analyzing results of cervical sagittal parameters in patients operated with polyetheretherketone cages without plate. J Craniovertebr Junction Spine. (2024) 15(2):230–5. 10.4103/jcvjs.jcvjs_35_24 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 11.Huang C, Sheng X, Wu T, Wang B, Wen D, He L, et al. Does the angulation of the screws in the zero-P implant affect the clinical and radiological outcomes of patients? Orthop Surg. (2024) 16(11):2699–707. 10.1111/os.14182 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 12.Elias E, Daoud A, Smith J, Elias C, Nasser Z. Assessing surgical outcomes for cage plate system versus stand-alone cage in anterior cervical discectomy and fusion: a systematic review and meta-analysis. World Neurosurg. (2024) 185:150–64. 10.1016/j.wneu.2024.02.079 [DOI] [PubMed] [Google Scholar]
  • 13.Wang Z, Zhu X, Wang Z, Zhu R, Chen G, Gao M, et al. Zero-P and ROI-C implants versus traditional titanium plate with cage to treat cervical spondylotic myelopathy: clinical and radiological results with 5 years of follow-up. BMC Musculoskelet Disord. (2023) 24(1):539. 10.1186/s12891-023-06657-7 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 14.Zhang P, Zheng H, Luo J, Xu J. Comparative efficacy of zero-profile implant and conventional cage-plate implant in the treatment of single-level degenerative cervical spondylosis: a systematic review and meta-analysis. J Orthop Surg Res. (2024) 19(1):364. 10.1186/s13018-024-04729-5 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 15.Zhang Y, Ju J, Wu J. Cervical disc replacement versus anterior cervical discectomy and fusion using stand-alone cage for degenerative cervical spondylosis: a systematic review and meta-analysis based on randomized controlled trials. Neurosurg Rev. (2026) 49(1):11. 10.1007/s10143-025-03939-7 [DOI] [PubMed] [Google Scholar]
  • 16.Shin JW, Jin HB, Park Y, Ha JW, Kim HS, Suk KS, et al. Comparing outcomes between cage alone and plate fixation in single-level anterior cervical fusion: a retrospective clinical series. Clin Orthop Surg. (2025) 17(3):417–26. 10.4055/cios24036 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 17.Durand WM, Khanna R, Nazario-Ferrer GI, Lee SH, Skolasky RL, Jain A. Revision surgery after single level anterior cervical discectomy and fusion with plate vs stand-alone cage over 2 to 5 year follow-up. Global Spine J. (2025) 15(4):2014–9. 10.1177/21925682241279528 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 18.Murphy TP, Tran JD, Colantonio DF, Le AH, Fredericks DR, Roach WB, et al. Biomechanical comparison of anterior cervical plate fixation versus integrated fixation cage for anterior cervical discectomy and fusion. Clin Spine Surg. (2025) 38(1):E1–6. 10.1097/BSD.0000000000001630 [DOI] [PubMed] [Google Scholar]
  • 19.Jin Z-, Teng Y, Wang H-, Yang H-, Lu Y-, Gan M-. Comparative analysis of cage subsidence in anterior cervical decompression and fusion: zero profile anchored spacer (ROI-C) vs. Conventional cage and plate construct. Front Surg. (2021) 8:736680. 10.3389/fsurg.2021.736680 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 20.Chen L, Liu D, Wang M, Huang Y, Chen Z. Anterior cervical discectomy and fusion with zero-profile anchored spacer versus plate and cage for 3-level contiguous cervical degenerative disease: a systematic review and meta-analysis. World Neurosurg. (2024) 190:228–39. 10.1016/j.wneu.2024.07.102 [DOI] [PubMed] [Google Scholar]
  • 21.Chang CJ, Liu YF, Hsiao YM, Chang WL, Huang YH, Liu KC, et al. Comparison of stand-alone anchored spacer and plate-cage construct for surgical treatment of multilevel cervical degenerative spondylopathy: a meta-analysis. Global Spine J. (2025) 15(7):3364–78. 10.1177/21925682251327599 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 22.Page MJ, McKenzie JE, Bossuyt PM, Boutron I, Hoffmann TC, Mulrow CD, et al. The PRISMA 2020 statement: an updated guideline for reporting systematic reviews. Br Med J. (2021) 372:n71. 10.1136/bmj.n71 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 23.Sterne JAC, Hernán MA, Reeves BC, Savović J, Berkman ND, Viswanathan M, et al. ROBINS-I: a tool for assessing risk of bias in non-randomised studies of interventions. Br Med J. (2016) 355:i4919. 10.1136/bmj.i4919 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 24.Guyatt GH, Oxman AD, Vist GE, Kunz R, Falck-Ytter Y, Alonso-Coello P, et al. GRADE: an emerging consensus on rating quality of evidence and strength of recommendations. Br Med J. (2008) 336(7650):924–6. 10.1136/bmj.39489.470347.AD [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 25.Shaikh A, Dwarakanath LV, Haleem S, Rehousek P, Hassan F. Comparative review of anchored cage devices and standalone cages in multilevel anterior cervical discectomy and fusion surgeries. J Craniovertebr Junction Spine. (2026) 17(1):43–7. 10.4103/jcvjs.jcvjs_195_25 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 26.Kim CH, Chung CK, Jahng TA, Park SB, Sohn S, Lee S. Segmental kyphosis after cervical interbody fusion with stand-alone polyetheretherketone (PEEK) cages: a comparative study on 2 different PEEK cages. J Spinal Disord Tech. (2015) 28(1):E17–24. 10.1097/BSD.0000000000000137 [DOI] [PubMed] [Google Scholar]
  • 27.Mu G, Chen H, Fu H, Wang S, Lu H, Yi X, et al. Anterior cervical discectomy and fusion with zero-profile versus stand-alone cages for two-level cervical spondylosis: a retrospective cohort study. Front Surg. (2022) 9:1002744. 10.3389/fsurg.2022.1002744 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 28.Virkar N, Bhilare P, Hadgaonkar S, Kothari A, Sancheti P, Aiyer S. Standalone cage versus anchored cage for anterior cervical discectomy and fusion: a comparative analysis of clinical and radiological outcomes. Int Orthop. (2022) 46(10):2339–45. 10.1007/s00264-022-05493-z [DOI] [PubMed] [Google Scholar]
  • 29.Balakumar B, Raju S, Marconi SD, Hassan MF. A pragmatic single centre retrospective comparative review of complication profile between PEEK cages and zero-P cage screw constructs. Br J Neurosurg. (2024) 38(4):904–10. 10.1080/02688697.2021.2005772 [DOI] [PubMed] [Google Scholar]
  • 30.Cho HJ, Hur JW, Lee JB, Han JS, Cho TH, Park JY. Cervical stand-alone polyetheretherketone cage versus zero-profile anchored spacer in single-level anterior cervical discectomy and fusion: minimum 2-year assessment of radiographic and clinical outcome. J Korean Neurosurg Soc. (2015) 58(2):119–24. 10.3340/jkns.2015.58.2.119 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 31.Gerszten PC, Paschel E, Mashaly H, Sabry H, Jalalod'din H, Saoud K. Outcomes evaluation of zero-profile devices compared to stand-alone PEEK cages for the treatment of three- and four-level cervical disc disease. Cureus. (2016) 8(9):e775. 10.7759/cureus.775 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 32.Khattab MF, Kotb A. Cervical stand-alone peek cage versus anchored cage with screws in single-level anterior cervical discectomy and fusion: a prospective cohort study. Curr Orthop Pract. (2020) 31(2):179–85. 10.1097/BCO.0000000000000853 [DOI] [Google Scholar]
  • 33.Kwon OI, Son DW, Lee SW, Song GS. Comparison of radiologic outcomes of different methods in single-level anterior cervical discectomy and fusion. Korean J Spine. (2016) 13(3):91–6. 10.14245/kjs.2016.13.3.91 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 34.Lee YS, Kim YB, Park SW. Does a zero-profile anchored cage offer additional stabilization as anterior cervical plate? Spine. (2015) 40(10):E563–70. 10.1097/BRS.0000000000000864 [DOI] [PubMed] [Google Scholar]
  • 35.McKee C, Espey R, O'Halloran A, Curran A, Darwish N. A retrospective evaluation and review of radiographic outcomes for anterior cervical discectomy and fusion (ACDF) procedures: northern Ireland’s experience. Cureus. (2023) 15(5):e38864. 10.7759/cureus.38864 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 36.Shin JS, Oh SH, Cho PG. Surgical outcome of a zero-profile device comparing with stand-alone cage and anterior cervical plate with iliac bone graft in the anterior cervical discectomy and fusion. Korean J Spine. (2014) 11(3):169–77. 10.14245/kjs.2014.11.3.169 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 37.Li P, Lei R, Gan L, Shangguan L, Liang Z, Chang L, et al. Comparing clinical and radiographic outcomes between the self-locking stand-alone cage and conventional cage-plate construct: a five-year retrospective cohort study. Spine. (2023) 48(1):56–66. 10.1097/BRS.0000000000004465 [DOI] [PubMed] [Google Scholar]
  • 38.Li Z, Zhao Y, Tang J, Ren D, Guo J, Wang H, et al. A comparison of a new zero-profile, stand-alone fidji cervical cage and anterior cervical plate for single and multilevel ACDF: a minimum 2-year follow-up study. Eur Spine J. (2017) 26(4):1129–39. 10.1007/s00586-016-4739-2 [DOI] [PubMed] [Google Scholar]
  • 39.McDonnell JM, Youssef S, Ross TD, Marland H, Turley L, Cunniffe G, et al. The efficacy of anchored stand-alone spacers in comparison to conventional cage and plate in anterior cervical discectomy and fusion surgery: a meta-analysis of randomised controlled trials for clinical and radiological outcomes. Brain Spine. (2024) 4:102748. 10.1016/j.bas.2024.102748 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 40.Zhang Y, Ju J, Wu J. Self-locking stand-alone cage versus cage-plate fixation in monosegmental anterior cervical discectomy and fusion with a minimum 2-year follow-up: a systematic review and meta-analysis. J Orthop Surg Res. (2023) 18(1):403. 10.1186/s13018-023-03885-4 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 41.Zhang Y, Ju J, Wu J. Zero-profile anchored spacer versus conventional plate-cage construct in bilevel anterior cervical discectomy and fusion: a systematic review and meta-analysis. J Orthop Surg Res. (2023) 18(1):644. 10.1186/s13018-023-04134-4 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 42.Scholz M, Schleicher P, Pabst S, Kandziora F. A zero-profile anchored spacer in multilevel cervical anterior interbody fusion: biomechanical comparison to established fixation techniques. Spine. (2015) 40(7):E375–80. 10.1097/BRS.0000000000000768 [DOI] [PubMed] [Google Scholar]
  • 43.Samartzis D, Shen FH, Goldberg EJ, An HS. Is autograft the gold standard in achieving radiographic fusion in one-level anterior cervical discectomy and fusion with rigid anterior plate fixation? Spine. (2005) 30(15):1756–61. 10.1097/01.brs.0000172148.86756.ce [DOI] [PubMed] [Google Scholar]
  • 44.Elder BD, Sankey EW, Theodros D, Bydon M, Rory Goodwin C, Lo SF, et al. Successful anterior fusion following posterior cervical fusion for revision of anterior cervical discectomy and fusion pseudarthrosis. J Clin Neurosci. (2016) 24:57–62. 10.1016/j.jocn.2015.07.019 [DOI] [PubMed] [Google Scholar]
  • 45.Tome-Bermejo F, Álvarez-Galovich L, Piñera-Parrilla ÁR, Mengis-Palleck CL, Cervera-Irimia J, Rodríguez-Bercial A, et al. Anterior 1-2 level cervical corpectomy and fusion for degenerative cervical disease: a retrospective study with lordotic porous tantalum cages. Long-term changes in sagittal alignment and their clinical and radiological implications after cage subsidence. Int J Spine Surg. (2022) 16(2):222–32. 10.14444/8207 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 46.Milczynska WM, Ahmad A, Ahmed AI, Panchmatia JR, Fakouri B, Liantis P, et al. Does titanium cage subsidence affect clinical outcomes in ACDF surgery? A tertiary center experience. Ann R Coll Surg Engl. (2023) 105(4):378–83. 10.1308/rcsann.2022.0050 [DOI] [PMC free article] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

Table1.docx (18.8KB, docx)

Data Availability Statement

The original contributions presented in the study are included in the article/Supplementary Material, further inquiries can be directed to the corresponding author/s.


Articles from Frontiers in Surgery are provided here courtesy of Frontiers Media SA

RESOURCES