Abstract
1. The light-adapted spectral sensitivity of the grey squirrel has been determined by an automated training method at a level about 6 log units above the squirrel's absolute threshold.
2. The maximum sensitivity is near 555 nm, under light-adapted conditions, compared with the dark-adapted maximum near 500 nm found by a similar method.
3. Neither the light-adapted nor the dark-adapted behavioural threshold agrees with electrophysiological findings using single flash techniques, but there is agreement with e.r.g. results obtained with sinusoidal stimuli.
Full text
PDFSelected References
These references are in PubMed. This may not be the complete list of references from this article.
- ARDEN G. B., SILVER P. H. Visual thresholds and spectral sensitivities of the grey squirrel (Sciurus carolinensis leucotis). J Physiol. 1962 Oct;163:540–557. doi: 10.1113/jphysiol.1962.sp006992. [DOI] [PMC free article] [PubMed] [Google Scholar]
- ARDEN G. B., TANSLEY K. The spectral sensitivity of the pure-cone retina of the grey squirrel (Sciurus carolinensis leucotis). J Physiol. 1955 Mar 28;127(3):592–602. doi: 10.1113/jphysiol.1955.sp005280. [DOI] [PMC free article] [PubMed] [Google Scholar]
- COHEN A. I. SOME OBSERVATIONS ON THE FINE STRUCTURE OF THE RETINAL RECEPTORS OF THE AMERICAN GRAY SQUIRREL. Invest Ophthalmol. 1964 Apr;3:198–216. [PubMed] [Google Scholar]
- DARTNALL H. J. A. The interpretation of spectral sensitivity curves. Br Med Bull. 1953;9(1):24–30. doi: 10.1093/oxfordjournals.bmb.a074302. [DOI] [PubMed] [Google Scholar]
- DARTNALL H. J. Visual pigment from a pure-cone retina. Nature. 1960 Nov 5;188:475–479. doi: 10.1038/188475a0. [DOI] [PubMed] [Google Scholar]
- DENTON E. J., PIRENNE M. H. The absolute sensitivity and functional stability of the human eye. J Physiol. 1954 Mar 29;123(3):417–442. doi: 10.1113/jphysiol.1954.sp005062. [DOI] [PMC free article] [PubMed] [Google Scholar]
- DONNER K. O. The spectral sensitivity of the pigeon's retinal elements. J Physiol. 1953 Dec 29;122(3):524–537. doi: 10.1113/jphysiol.1953.sp005018. [DOI] [PMC free article] [PubMed] [Google Scholar]
- GOURAS P. DUPLEX FUNCTION IN THE GREY SQUIRREL'S ELECTRORETINOGRAM. Nature. 1964 Aug 15;203:767–768. doi: 10.1038/203767a0. [DOI] [PubMed] [Google Scholar]
- Ikeda H. The spectral sensitivity of the pigeon (Columba livia). Vision Res. 1965 Jan;5(1):19–36. doi: 10.1016/0042-6989(65)90072-6. [DOI] [PubMed] [Google Scholar]
- WEALE R. A. Bleaching experiments on eyes of living grey squirrels (Sciurus carolinensis leucotis). J Physiol. 1955 Mar 28;127(3):587–591. doi: 10.1113/jphysiol.1955.sp005279. [DOI] [PMC free article] [PubMed] [Google Scholar]