Skip to main content
Clinical and Experimental Immunology logoLink to Clinical and Experimental Immunology
. 1977 Apr;28(1):180–188.

Specific removal of antibody by extracorporeal circulation over antigen immobilized in collodion-charcoal.

D S Terman, T Tavel, D Petty, M R Racic, G Buffaloe
PMCID: PMC1540887  PMID: 862246

Abstract

Studies were undertaken to determine whether BSA immobilized in collodion membranes adherent to activated charcoal particles, would be capable of specifically removing circulating BSA antibody in vitro and in vivo in an extracorporeal system in dogs. Up to 59-8 mg of BSA were retained in collodion membranes adherent to small particles. In vitro studies demonstrated that immobilized BSA could specifically reduce BSA binding activity from circulating antisera. For in vivo studies, an extracorporeal circulation system was established and arterial blood was circualted through a continuous flow celltrifuge in which plasma was separated from formed elements of the blood. Only plasma was circulated over the BSA collodion-charcoal immunoadsorbent. Anti-BSA and anti-HSA atibodies were passively infused into dogs and, after an equlibration period of 12 or 15 min, plasma was passed over the BSA collodion-charcoal immunoadsorben. Plasma exhibited a sharp reduction in BSA binding over the next 30-60 min with only slight reduction in anti-HSA binding the same period. Dogs, actively immunized to BSA and HSA, were also treated by extracorporeal plasma perfusion over BSA collodion-charcoal. A specific decline in BSA binding of sera, was again observed with minimal changes in HSA binding. A post-perfusion rebound of BSA binding was observed which reached pre-perfusion levels after 6-8 days. A second treatment during the rebound period also resulted in a specific decline in BSA binding with a similar pattern of antibody rebound. There were no significant changes in I-labelled BSA recorded on the charcoal before and after in vivo procedures and no signifcant alterations in haematocrit, serum sodium, potassium, calcium, magnesium or creatinine levels before and after the procedures. These data suggests that antigen-coated charcoal may specifically withdraw circulating antibodies in vivo with minimal release of the entrapped antigen and little alteration in the host's haematological and biochemical status.

Full text

PDF
183

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Bertino J. R. Chemical action and pharmacology of methotrexate, azathioprine and cyclophosphamide in man. Arthritis Rheum. 1973 Jan-Feb;16(1):79–83. doi: 10.1002/art.1780160113. [DOI] [PubMed] [Google Scholar]
  2. Cochrane C. G., Koffler D. Immune complex disease in experimental animals and man. Adv Immunol. 1973;16(0):185–264. doi: 10.1016/s0065-2776(08)60298-9. [DOI] [PubMed] [Google Scholar]
  3. FARR R. S. A quantitative immunochemical measure of the primary interaction between I BSA and antibody. J Infect Dis. 1958 Nov-Dec;103(3):239–262. doi: 10.1093/infdis/103.3.239. [DOI] [PubMed] [Google Scholar]
  4. Graw R. G., Jr, Herzig G. P., Eisel R. J., Perry S. Leukocyte and platelet collection from normal donors with the continuous flow blood cell separator. Transfusion. 1971 Mar-Apr;11(2):94–101. doi: 10.1111/j.1537-2995.1971.tb04383.x. [DOI] [PubMed] [Google Scholar]
  5. Ishizaka K., Tomioka H., Ishizaka T. Mechanisms of passive sensitization. I. Presence of IgE and IgG molecules on human leukocytes. J Immunol. 1970 Dec;105(6):1459–1467. [PubMed] [Google Scholar]
  6. Lyle L. R., Parker B. M., Parker C. W. The use of protein-substituted nylon catheters for selective immunoadsorption in vivo. J Immunol. 1974 Aug;113(2):517–521. [PubMed] [Google Scholar]
  7. McConahey P. J., Dixon F. J. A method of trace iodination of proteins for immunologic studies. Int Arch Allergy Appl Immunol. 1966;29(2):185–189. doi: 10.1159/000229699. [DOI] [PubMed] [Google Scholar]
  8. McCullough J., Fortuny I. E., Kennedy B. J., Edson J. R., Branda R. F., Jacob H. S. Rapid plasma exchange with the continuous flow centrifuge. Transfusion. 1973 Mar;13(2):94–99. doi: 10.1111/j.1537-2995.1973.tb05447.x. [DOI] [PubMed] [Google Scholar]
  9. Rowley D. A., Fitch F. W., Stuart F. P., Köhler H., Cosenza H. Specific suppression of immune responses. Science. 1973 Sep 21;181(4105):1133–1141. doi: 10.1126/science.181.4105.1133. [DOI] [PubMed] [Google Scholar]
  10. Terman D. S., Petty D., Ogden D., Pefley C., Buffaloe G. Specific extraction of antigen in vivo by extracorporeal circulation over antibody immobilized in collodion-charcoal. J Immunol. 1976 Nov;117(5 PT2):1971–1975. [PubMed] [Google Scholar]
  11. Terman D. S., Stewart I., Robinette J., Carr R., Harbeck R. Specific removal of DNA antibodies in vivo with an extracorporeal immuno-adsorbent. Clin Exp Immunol. 1976 May;24(2):231–237. [PMC free article] [PubMed] [Google Scholar]
  12. Terman D. S., Tavel A., Tavel T., Petty D., Harbeck R., Buffaloe G., Carr R. Degradation of circulating DNA by extracorporeal circulation over nuclease immobilized on nylon microcapsules. J Clin Invest. 1976 May;57(5):1201–1212. doi: 10.1172/JCI108388. [DOI] [PMC free article] [PubMed] [Google Scholar]
  13. Terman D. S., Tavel T., Petty D., Tavel A., Harbeck R., Buffaloe G., Carr R. Specific removal of bovine serum albumin (BSA) antibodies in vivo by extracorporeal circulation over BSA immobilized on nylon microcapsules. J Immunol. 1976 May;116(5):1337–1341. [PubMed] [Google Scholar]

Articles from Clinical and Experimental Immunology are provided here courtesy of British Society for Immunology

RESOURCES