Skip to main content
Archives of Disease in Childhood logoLink to Archives of Disease in Childhood
. 1982 Apr;57(4):297–300. doi: 10.1136/adc.57.4.297

Simple estimate of creatinine clearance from plasma creatinine in neonates.

G Zacchello, M Bondio, O S Saia, G Largaiolli, R Vedaldi, F F Rubaltelli
PMCID: PMC1627640  PMID: 7082044

Abstract

Thirteen newborn infants, 8 preterm and 5 term, with either mild or serious neonatal asphyxia were studied. From the first 24 hours of life to day 13, glomerular filtration rate (GFR) estimated by creatinine clearance was compared with the values obtained using Schwartz's formula: GFR (ml/min per 1.73 m2) = 0.55 x length (cm)/plasma creatinine (mg/100 ml). Both in term and preterm infants, values of formula-calculated creatinine clearance were slightly higher than values obtained by the classical method; nevertheless the data show significant correlations, respectively r = 0.867 and r = 0.795 (P less than 0.001). This formula provides an adequate estimation of neonatal creatinine clearance (a marker for GFR) directly from plasma creatinine provided that body length is taken into consideration. The necessity for urine collection and the associated problems are thus obviated. The simplicity of Schwartz's formula permits easy monitoring of renal function, especially in neonatal asphyxia in which the risk of developing renal failure is great.

Full text

PDF
299

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Broberger U., Aperia A. Renal function in infants with hyperbilirubinemia. Acta Paediatr Scand. 1979 Jan;68(1):75–79. doi: 10.1111/j.1651-2227.1979.tb04433.x. [DOI] [PubMed] [Google Scholar]
  2. Counahan R., Chantler C., Ghazali S., Kirkwood B., Rose F., Barratt T. M. Estimation of glomerular filtration rate from plasma creatinine concentration in children. Arch Dis Child. 1976 Nov;51(11):875–878. doi: 10.1136/adc.51.11.875. [DOI] [PMC free article] [PubMed] [Google Scholar]
  3. Davies D. P., Holding R. E. Neonatometer: a new infant length measurer. Arch Dis Child. 1972 Dec;47(256):938–940. doi: 10.1136/adc.47.256.938. [DOI] [PMC free article] [PubMed] [Google Scholar]
  4. Fawer C. L., Torrado A., Guignard J. P. Single injection clearance in the neonate. Biol Neonate. 1979;35(5-6):321–324. doi: 10.1159/000241192. [DOI] [PubMed] [Google Scholar]
  5. Schwartz G. J., Haycock G. B., Edelmann C. M., Jr, Spitzer A. A simple estimate of glomerular filtration rate in children derived from body length and plasma creatinine. Pediatrics. 1976 Aug;58(2):259–263. [PubMed] [Google Scholar]
  6. Sertel H. Letter: Rates of creatinine and urea clearance in preterm infants on the 3rd day after birth. Arch Dis Child. 1974 Jan;49(1):79–80. doi: 10.1136/adc.49.1.79. [DOI] [PMC free article] [PubMed] [Google Scholar]
  7. Sertel H., Scopes J. Rates of creatinine clearance in babies less than one week of age. Arch Dis Child. 1973 Sep;48(9):717–720. doi: 10.1136/adc.48.9.717. [DOI] [PMC free article] [PubMed] [Google Scholar]
  8. Stonestreet B. S., Bell E. F., Oh W. Validity of endogenous creatinine clearance in low birthweight infants. Pediatr Res. 1979 Sep;13(9):1012–1014. doi: 10.1203/00006450-197909000-00013. [DOI] [PubMed] [Google Scholar]
  9. Szelid Z., Méhes K. Estimation of glomerular filtration rate from plasma creatinine concentration in children of various ages. Arch Dis Child. 1977 Aug;52(8):669–670. doi: 10.1136/adc.52.8.669. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from Archives of Disease in Childhood are provided here courtesy of BMJ Publishing Group

RESOURCES