Abstract
In the use of low-level intravenous insulin infusion for treating diabetic hyperglycaemia and ketoacidosis adsorption of insulin to containers or plastic infusion apparatus results in significant losses of 60-80% of insulin in dilute physiological saline solution (40 U/l). It is therefore necessary to add protein to the carrier solution to minimize losses and maintain a constant delivery rate. Recovery studies showed that 3.5% w/v polygeline solution (polymer of degraded gelatin) was a suitable medium for this purpose, offering some advantages over human serum albumin. A minimum concentration of 0.5% polygeline was required to ensure adequate delivery of insulin to the patient.
Full text
PDFSelected References
These references are in PubMed. This may not be the complete list of references from this article.
- FREINKEL N., GOODNER C. J. Carbohydrate metabolism in pregnancy. I. The metabolism of insulin by human placental tissue. J Clin Invest. 1960 Jan;39:116–131. doi: 10.1172/JCI104010. [DOI] [PMC free article] [PubMed] [Google Scholar]
- HILL J. B. The adsorption of I131-insulin to glass. Endocrinology. 1959 Sep;65:515–517. doi: 10.1210/endo-65-3-515. [DOI] [PubMed] [Google Scholar]
- Kidson W., Casey J., Kraegen E., Lazarus L. Treatment of severe diabetes mellitus by insulin infusion. Br Med J. 1974 Jun 29;2(5921):691–694. doi: 10.1136/bmj.2.5921.691. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Petty C., Cunningham N. L. Insulin adsorption by glass infusion bottles, polyvinylchloride infusion containers, and intravenous tubing. Anesthesiology. 1974 Apr;40(4):400–404. doi: 10.1097/00000542-197404000-00018. [DOI] [PubMed] [Google Scholar]
- Semple P. F., White C., Manderson W. G. Continuous intravenous infusion of small doses of insulin in treatment of diabetic ketoacidosis. Br Med J. 1974 Jun 29;2(5921):694–698. doi: 10.1136/bmj.2.5921.694. [DOI] [PMC free article] [PubMed] [Google Scholar]
- WISEMAN R., Jr, BALTZ B. E. Prevention of insulin-I-131 adsorption to glass. Endocrinology. 1961 Feb;68:354–356. doi: 10.1210/endo-68-2-354. [DOI] [PubMed] [Google Scholar]
- Weisenfeld S., Podolsky S., Goldsmith L., Ziff L. Adsorption of insulin to infusion bottles and tubing. Diabetes. 1968 Dec;17(12):766–771. doi: 10.2337/diab.17.12.766. [DOI] [PubMed] [Google Scholar]
- Young J. D., Kraegen E. W. Simultaneous assay of insulin and glucagon in serum. Aust J Exp Biol Med Sci. 1968 Dec;46(6):697–705. doi: 10.1038/icb.1968.176. [DOI] [PubMed] [Google Scholar]