Skip to main content
British Medical Journal logoLink to British Medical Journal
. 1976 Nov 27;2(6047):1281–1284. doi: 10.1136/bmj.2.6047.1281

Effect of intravenous dextran 70 and pneumatic leg compression on incidence of postoperative pulmonary embolism.

N L Browse, G Clemenson, N T Bateman, J I Gaunt, D N Croft
PMCID: PMC1689986  PMID: 1000195

Abstract

The incidence of pulmonary embolism and deep vein thrombosis was measured in 50 matched pairs of patients undergoing common surgical procedures with preoperative and postoperative ventilation-perfusion lung scans and the fibrinogen uptake test. One patient in each pair was treated with intravenous dextran 70 and pneumatic leggings. The incidence of pulmonary embolism among the treated patients was significantly reduced from 24% to 8%, but the incidence of deep vein thrombosis was not significantly reduced (34% to 24%).

Full text

PDF
1284

Images in this article

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. ALLISON P. R., DUNNILL M. S., MARSHALL R. Pulmonary embolism. Thorax. 1960 Dec;15:273–283. doi: 10.1136/thx.15.4.273. [DOI] [PMC free article] [PubMed] [Google Scholar]
  2. Browse N. L., Clemenson G., Croft D. N. Fibrinogen-detectable thrombosis in the legs and pulmonary embolism. Br Med J. 1974 Mar 30;1(5908):603–604. doi: 10.1136/bmj.1.5908.603. [DOI] [PMC free article] [PubMed] [Google Scholar]
  3. COON W. W., COLLER F. A. Some epidemiologic considerations of thromboembolism. Surg Gynecol Obstet. 1959 Oct;109:487–501. [PubMed] [Google Scholar]
  4. FREIMAN D. G., SUYEMOTO J., WESSLER S. FREQUENCY OF PULMONARY THROMBOEMBOLISM IN MAN. N Engl J Med. 1965 Jun 17;272:1278–1280. doi: 10.1056/NEJM196506172722406. [DOI] [PubMed] [Google Scholar]
  5. Negus D., Pinto D. J., Le Quesne L. P., Brown N., Chapman M. 125-I-labelled fibrinogen in the diagnosis of deep-vein thrombosis and its correlation with phlebography. Br J Surg. 1968 Nov;55(11):835–839. [PubMed] [Google Scholar]
  6. Williams O., Lyall J., Vernon M., Croft D. N. Ventilation-perfusion lung scanning for pulmonary emboli. Br Med J. 1974 Mar 30;1(5908):600–602. doi: 10.1136/bmj.1.5908.600. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from British Medical Journal are provided here courtesy of BMJ Publishing Group