Skip to main content
Applied and Environmental Microbiology logoLink to Applied and Environmental Microbiology
. 1976 Jul;32(1):80–84. doi: 10.1128/aem.32.1.80-84.1976

Influence of possible disinfectant transfer on Staphylococcus aureus plate counts after agar contact sampling.

B Brummer
PMCID: PMC170009  PMID: 788638

Abstract

Asbestos-vinyl tile floor panels were mopped with three types of chemical disinfectant product, as well as after contact, with the untreated control panel were prepared according to the manufacturer's label instructions. Similar floor panels were inoculated artificially with Staphylococcus aureus. RODAC (replicate organism detection and counting) surface sampling plates were pressed to the disinfectant-treated panels or to the untreated control panel and then immediately pressed to sampling sites on the artificially inoculated floor panels. Plate counts were determined after contact with panels treated with each type of disinfectant, product, as well as after contact with the untreated control panel. Results indicate that disinfectant residues on environmental surfaces do not alter the average plate counts obtained by RODAC samplings.

Full text

PDF
83

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Favero M. S., McDade J. J., Robertsen J. A., Hoffman R. K., Edwards R. W. Microbiological sampling of surfaces. J Appl Bacteriol. 1968 Sep;31(3):336–343. doi: 10.1111/j.1365-2672.1968.tb00375.x. [DOI] [PubMed] [Google Scholar]
  2. GOLDSMITH M. T., LATLIEF M. A., FRIEDL J. L., STUART L. S. Adsorption of available chlorine and quaternary by cotton and wool fabrics from disinfecting solutions. Appl Microbiol. 1954 Nov;2(6):360–364. doi: 10.1128/am.2.6.360-364.1954. [DOI] [PMC free article] [PubMed] [Google Scholar]
  3. HALL L. B., HARTNETT M. J. MEASUREMENT OF THE BACTERIAL CONTAMINATION ON SURFACES IN HOSPITALS. Public Health Rep. 1964 Nov;79:1021–1024. [PMC free article] [PubMed] [Google Scholar]
  4. Mallison G. F. Housekeeping in operating suites. AORN J. 1975 Feb;21(2):213–220. doi: 10.1016/s0001-2092(07)60999-5. [DOI] [PubMed] [Google Scholar]
  5. ROHDE P. A. A new culture plate: its applications. Bull Parenter Drug Assoc. 1963 Jan-Feb;17:11–13. [PubMed] [Google Scholar]
  6. Walter W. G., Hucker G. J. Proposed Method for the Bacteriological Examination of Flat Surfaces. Am J Public Health Nations Health. 1941 May;31(5):487–490. doi: 10.2105/ajph.31.5.487. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from Applied and Environmental Microbiology are provided here courtesy of American Society for Microbiology (ASM)

RESOURCES