Abstract
The accuracy of blood pressure measurements obtained from very low birthweight (less than 1500 g) neonates using the Dinamap oscillometric monitor was investigated. Comparisons using umbilical artery measurements showed that the monitor is less reliable in the lower pressure range and specifically that it tends to overestimate pressure in hypotensive infants.
Full text
PDFSelected References
These references are in PubMed. This may not be the complete list of references from this article.
- Butt W. W., Whyte H. Blood pressure monitoring in neonates: comparison of umbilical and peripheral artery catheter measurements. J Pediatr. 1984 Oct;105(4):630–632. doi: 10.1016/s0022-3476(84)80437-0. [DOI] [PubMed] [Google Scholar]
- Dellagrammaticas H. D., Wilson A. J. Clinical evaluation of the Dinamap non-invasive blood pressure monitor in pre-term neonates. Clin Phys Physiol Meas. 1981 Nov;2(4):271–276. doi: 10.1088/0143-0815/2/4/003. [DOI] [PubMed] [Google Scholar]
- Evans D. H., Lark G. M., Archer L. N., Levene M. I. The continuous measurement of intra-arterial pressure in the neonate: method and accuracy. Clin Phys Physiol Meas. 1986 May;7(2):179–184. doi: 10.1088/0143-0815/7/2/008. [DOI] [PubMed] [Google Scholar]
- Friesen R. H., Lichtor J. L. Indirect measurement of blood pressure in neonates and infants utilizing an automatic noninvasive oscillometric monitor. Anesth Analg. 1981 Oct;60(10):742–745. [PubMed] [Google Scholar]
- Kimble K. J., Darnall R. A., Jr, Yelderman M., Ariagno R. L., Ream A. K. An automated oscillometric technique for estimating mean arterial pressure in critically ill newborns. Anesthesiology. 1981 May;54(5):423–425. doi: 10.1097/00000542-198105000-00016. [DOI] [PubMed] [Google Scholar]
- Lui K., Doyle P. E., Buchanan N. Oscillometric and intra-arterial blood pressure measurements in the neonate: a comparison of methods. Aust Paediatr J. 1982 Mar;18(1):32–34. doi: 10.1111/j.1440-1754.1982.tb01975.x. [DOI] [PubMed] [Google Scholar]
- Pellegrini-Caliumi G., Agostino R., Nodari S., Maffei G., Moretti C., Bucci G. Evaluation of an automatic oscillometric method and of various cuffs for the measurement of arterial pressure in the neonate. Acta Paediatr Scand. 1982 Sep;71(5):791–797. doi: 10.1111/j.1651-2227.1982.tb09521.x. [DOI] [PubMed] [Google Scholar]
- Versmold H. T., Kitterman J. A., Phibbs R. H., Gregory G. A., Tooley W. H. Aortic blood pressure during the first 12 hours of life in infants with birth weight 610 to 4,220 grams. Pediatrics. 1981 May;67(5):607–613. [PubMed] [Google Scholar]