Skip to main content
Antimicrobial Agents and Chemotherapy logoLink to Antimicrobial Agents and Chemotherapy
. 1981 Jun;19(6):987–992. doi: 10.1128/aac.19.6.987

Effect of ionized calcium and soluble magnesium on the predictability of the performance of Mueller-Hinton agar susceptibility testing of Pseudomonas aeruginosa with gentamicin.

E Casillas, M A Kenny, B H Minshew, F D Schoenknecht
PMCID: PMC181596  PMID: 6791589

Abstract

The soluble and ionized calcium and magnesium contents of 18 lots of Mueller-Hinton agar medium from three different manufacturers were analyzed, and the results were correlated with medium performance. A standardized disk diffusion test, with Pseudomonas aeruginosa (ATCC 27853) and a 10-microgram gentamicin disk, served as an indicator of medium performance. Zone diameters correlated well with the ionized calcium values and the sum of the ionized calcium and soluble magnesium values in the different lots (r = -0.88 for both). Zone diameters correlated poorly with ionized magnesium values (r = -0.57), which were best described by a curvilinear relationship. Supplementation of lots of Mueller-Hinton agar medium with equivalent amounts of calcium and magnesium as the chloride, gluconate, or glycerophosphate salts produced identical decreases in zone sizes. Adjustment of deficient lots of Mueller-Hinton agar medium with ionized calcium or soluble magnesium or both (as the gluconate salts), to match the concentrations in lots that provided satisfactory zone sizes (17 to 19 mm), resulted in performance comparable to that of the control lots. Sixteen strains of Pseudomonas aeruginosa, ranging from resistant to susceptible, responded to cation adjustment in the same manner as the ATCC quality control strain. Satisfactory medium performance can obviously be assured by biological means in aminoglycoside susceptibility testing of Pseudomonas aeruginosa on Mueller-Hinton medium; however, cation adjustment of medium to predetermined levels of ionized calcium and soluble magnesium can now also provide desirable performance levels for P. aeruginosa on Mueller-Hinton medium.

Full text

PDF
990

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Kenny M. A., Pollock H. M., Minshew B. H., Casillas E., Schoenknecht F. D. Cation components of Mueller-Hinton agar affecting testing of Pseudomonas aeruginosa susceptibility to gentamicin. Antimicrob Agents Chemother. 1980 Jan;17(1):55–62. doi: 10.1128/aac.17.1.55. [DOI] [PMC free article] [PubMed] [Google Scholar]
  2. Pollock H. M., Minshew B. H., Kenny M. A., Schoenknecht F. D. Effect of different lots of Mueller-Hinton agar on the interpretation of the gentamicin susceptibility of Pseudomonas aeruginosa. Antimicrob Agents Chemother. 1978 Sep;14(3):360–367. doi: 10.1128/aac.14.3.360. [DOI] [PMC free article] [PubMed] [Google Scholar]
  3. Reller L. B., Schoenknecht F. D., Kenny M. A., Sherris J. C. Antibiotic susceptibility testing of Pseudomonas aeruginosa: selection of a control strain and criteria for magnesium and calcium content in media. J Infect Dis. 1974 Nov;130(5):454–463. doi: 10.1093/infdis/130.5.454. [DOI] [PubMed] [Google Scholar]
  4. Scarpa A. Indicators of free magnesium in biological systems. Biochemistry. 1974 Jul 2;13(14):2789–2794. doi: 10.1021/bi00711a001. [DOI] [PubMed] [Google Scholar]
  5. Washington J. A., 2nd, Snyder R. J., Kohner P. C., Wiltse C. G., Ilstrup D. M., McCall J. T. Effect of cation content of agar on the activity of gentamicin, tobramycin, and amikacin against Pseudomonas aeruginosa. J Infect Dis. 1978 Feb;137(2):103–111. doi: 10.1093/infdis/137.2.103. [DOI] [PubMed] [Google Scholar]
  6. Waterworth P. M. Uniformity in sensitivity test media. J Antimicrob Chemother. 1978 Jan;4(1):4–6. doi: 10.1093/jac/4.1.4. [DOI] [PubMed] [Google Scholar]

Articles from Antimicrobial Agents and Chemotherapy are provided here courtesy of American Society for Microbiology (ASM)

RESOURCES