Skip to main content
Applied Microbiology logoLink to Applied Microbiology
. 1975 Oct;30(4):519–524. doi: 10.1128/am.30.4.519-524.1975

Enumeration of High Numbers of Bacteria Using Hydrophobic Grid-Membrane Filters

Anthony N Sharpe 1, Gregory L Michaud 1
PMCID: PMC187223  PMID: 1103728

Abstract

Printing a wax grid on a conventional membrane filter yields a device functioning as a most probable number apparatus (MPN), used at a single dilution but with a very large number of growth compartments (e.g., 3,650). By restraining the lateral spread and confluence of colonies, the hydrophobic grid-membrane filter (HGMF) allows growth- or colony-forming units (GU) to be resolved at levels far above those which produce an uncountable lawn on a conventional membrane filter. It also eliminates the size variation of normal bacterial colonies. As a result, the HGMF can give more accurate estimates of the concentration of GU. The method by which grid-cell count observations can be used to obtain MPN estimates of the number of GUs is described, and estimates obtained using the MPN method on the HGMF are compared with those resulting from conventional colony count procedures on membrane filters. A linear relation was observed between MPNGU and the number of GUs, at levels up to 30,000 GUs, for pure cultures of bacteria and for samples of natural waters. The HGMF has great potential for reducing the labor required in quantitative microbiology, since it allows, with one filter, enumeration of microorganisms over a very large concentration range and therefore reduces the need to make dilutions.

Full text

PDF
523

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Presswood W. G., Brown L. R. Comparison of Gelman and Millipore membrane filters for enumerating fecal coliform bacteria. Appl Microbiol. 1973 Sep;26(3):332–336. doi: 10.1128/am.26.3.332-336.1973. [DOI] [PMC free article] [PubMed] [Google Scholar]
  2. Schaeffer D. J., Long M. C., Janardan K. G. Statistical analysis of the recovery of coliform organisms on Gelman and Millipore membrane filters. Appl Microbiol. 1974 Oct;28(4):605–607. doi: 10.1128/am.28.4.605-607.1974. [DOI] [PMC free article] [PubMed] [Google Scholar]
  3. Sharpe A. N. Machine for printing hydrophobic grids on membrane filters. Appl Microbiol. 1975 Jul;30(1):110–112. doi: 10.1128/am.30.1.110-112.1975. [DOI] [PMC free article] [PubMed] [Google Scholar]
  4. Sharpe A. N., Michaud G. L. Hydrophobic grid-membrane filters: new approach to microbiological enumeration. Appl Microbiol. 1974 Aug;28(2):223–225. doi: 10.1128/am.28.2.223-225.1974. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from Applied Microbiology are provided here courtesy of American Society for Microbiology (ASM)

RESOURCES