Skip to main content
Applied and Environmental Microbiology logoLink to Applied and Environmental Microbiology
. 1987 Apr;53(4):761–767. doi: 10.1128/aem.53.4.761-767.1987

Comparison of methods for rotavirus detection in water and results of a survey of Jerusalem wastewater.

N Guttman-Bass, Y Tchorsh, E Marva
PMCID: PMC203752  PMID: 3034156

Abstract

Methods for the detection of viable rotaviruses and rotavirus antigen in water were developed and compared. The methods included laboratory-developed enzyme-linked immunosorbent assays (ELISAs) with chromogenic and luminescent substrates, commercial Rotazyme and Enzygnost ELISAs, and an indirect immunofluorescent assay. Of the methods tested, the immunofluorescent assay and the Enzygnost ELISA were the most sensitive for the simian rotavirus SA-11. All of the methods were positive for human rotavirus from clinical specimens. Seeded SA-11 rotavirus was concentrated from water by absorption to and elution from Zeta Plus filters followed by organic flocculation. Interference with the assays by components of the wastewater concentrates was minimal for the ELISAs, although the undiluted organic flocs were cytotoxic for the immunofluorescent assay. A survey of Jerusalem wastewater was carried out over the course of 1 year, and samples were assayed for rotaviruses and enteroviruses. Although enteroviruses were found in almost all of the samples, all samples were negative for rotaviruses. The concentration of rotaviruses in the wastewater was thus below the detection limit of the method used.

Full text

PDF
766

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Agbalika F., Wullenweber M., Prévot J. Preliminary evaluation of the ELISA as a tool for the detection of rotaviruses in activated sewage sludge. Zentralbl Bakteriol Mikrobiol Hyg B. 1985 May;180(5-6):534–539. [PubMed] [Google Scholar]
  2. Boorsma D. M., Streefkerk J. G. Periodate or glutaraldehyde for preparing peroxidase conjugates? J Immunol Methods. 1979;30(3):245–255. doi: 10.1016/0022-1759(79)90098-x. [DOI] [PubMed] [Google Scholar]
  3. Cukor G., Blacklow N. R. Human viral gastroenteritis. Microbiol Rev. 1984 Jun;48(2):157–179. doi: 10.1128/mr.48.2.157-179.1984. [DOI] [PMC free article] [PubMed] [Google Scholar]
  4. Guttman-Bass N., Armon R. Concentration of simian rotavirus SA-11 from tap water by membrane filtration and organic flocculation. Appl Environ Microbiol. 1983 Mar;45(3):850–855. doi: 10.1128/aem.45.3.850-855.1983. [DOI] [PMC free article] [PubMed] [Google Scholar]
  5. Hejkal T. W., Smith E. M., Gerba C. P. Seasonal occurrence of rotavirus in sewage. Appl Environ Microbiol. 1984 Mar;47(3):588–590. doi: 10.1128/aem.47.3.588-590.1984. [DOI] [PMC free article] [PubMed] [Google Scholar]
  6. Hurst C. J., Goyke T. Reduction of interfering cytotoxicity associated with wastewater sludge concentrates assayed for indigenous enteric viruses. Appl Environ Microbiol. 1983 Jul;46(1):133–139. doi: 10.1128/aem.46.1.133-139.1983. [DOI] [PMC free article] [PubMed] [Google Scholar]
  7. Moosai R. B., Gardner P. S., Almeida J. D., Greenaway M. A. A simple immunofluorescent technique for the detection of human rotavirus. J Med Virol. 1979;3(3):189–194. doi: 10.1002/jmv.1890030304. [DOI] [PubMed] [Google Scholar]
  8. Morinet F., Ferchal F., Colimon R., Pérol Y. Comparison of six methods for detecting human rotavirus in stools. Eur J Clin Microbiol. 1984 Apr;3(2):136–140. doi: 10.1007/BF02014331. [DOI] [PMC free article] [PubMed] [Google Scholar]
  9. Pai C. H., Shahrabadi M. S., Ince B. Rapid diagnosis of rotavirus gastroenteritis by a commercial latex agglutination test. J Clin Microbiol. 1985 Nov;22(5):846–850. doi: 10.1128/jcm.22.5.846-850.1985. [DOI] [PMC free article] [PubMed] [Google Scholar]
  10. Rose J. B., Singh S. N., Gerba C. P., Kelley L. M. Comparison of microporous filters for concentration of viruses from wastewater. Appl Environ Microbiol. 1984 May;47(5):989–992. doi: 10.1128/aem.47.5.989-992.1984. [DOI] [PMC free article] [PubMed] [Google Scholar]
  11. Smith E. M., Gerba C. P. Development of a method for detection of human rotavirus in water and sewage. Appl Environ Microbiol. 1982 Jun;43(6):1440–1450. doi: 10.1128/aem.43.6.1440-1450.1982. [DOI] [PMC free article] [PubMed] [Google Scholar]
  12. Wyatt R. G., James H. D., Jr, Pittman A. L., Hoshino Y., Greenberg H. B., Kalica A. R., Flores J., Kapikian A. Z. Direct isolation in cell culture of human rotaviruses and their characterization into four serotypes. J Clin Microbiol. 1983 Aug;18(2):310–317. doi: 10.1128/jcm.18.2.310-317.1983. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from Applied and Environmental Microbiology are provided here courtesy of American Society for Microbiology (ASM)

RESOURCES