Abstract
FAN medium was formulated to improve microbial recovery, particularly for fastidious microorganisms and for microorganisms causing sepsis in patients receiving antimicrobial therapy. In a controlled clinical evaluation performed at four university-affiliated hospitals, FAN anaerobic bottles were compared with standard anaerobic bottles for yield, speed of detection of microbial growth, and detection of septic episodes. A total of 10,431 blood culture sets were received; both anaerobic bottles of 7,694 blood culture sets were adequately filled with blood. Altogether, 925 isolates were recovered: 557 that were the cause of sepsis, 99 that were indeterminate as the cause of sepsis, and 269 contaminants. More Staphylococcus aureus (P < 0.001), coagulase-negative staphylococci (P < 0.001), Escherichia coli (P < 0.02), and all microorganisms combined (P < 0.005) were recovered from FAN bottles; more nonfermentative gram-negative bacilli (P < 0.05), Torulopsis glabrata (P < 0.001), and other yeasts (P < 0.01) were recovered from standard bottles. Growth of S. aureus (P < 0.001), coagulase-negative staphylococci (P < 0.001), Enterococcus faecalis (P < 0.025), streptococci other than Streptococcus pneumoniae (P < 0.01), and all microorganisms combined (P < 0.001) was detected earlier in standard bottles; growth of more isolates of E. coli (P < 0.05) and anaerobic bacteria (P < 0.01) was detected earlier in FAN bottles. The mean times to detection were 14.2 and 16.1 h for standard and FAN bottles, respectively.(ABSTRACT TRUNCATED AT 250 WORDS)
Full Text
The Full Text of this article is available as a PDF (345.5 KB).
Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Appelbaum P. C., Beckwith D. G., Dipersio J. R., Dyke J. W., Salventi J. F., Stone L. L. Enhanced detection of bacteremia with a new BACTEC resin blood culture medium. J Clin Microbiol. 1983 Jan;17(1):48–51. doi: 10.1128/jcm.17.1.48-51.1983. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Appleman M. D., Swinney R. S., Heseltine P. N. Evaluation of the Antibiotic Removal Device. J Clin Microbiol. 1982 Feb;15(2):278–281. doi: 10.1128/jcm.15.2.278-281.1982. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Bille J., Stockman L., Roberts G. D. Detection of yeasts and filamentous fungi in blood cultures during a 10-year period (1972 to 1981). J Clin Microbiol. 1982 Nov;16(5):968–970. doi: 10.1128/jcm.16.5.968-970.1982. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Doern G. V., Gantz N. M. Detection of bacteremia in patients receiving antimicrobial therapy: an evaluation of the antimicrobial removal device and 16B medium. J Clin Microbiol. 1983 Jul;18(1):43–48. doi: 10.1128/jcm.18.1.43-48.1983. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Gantz N. M., Medeiros A. A., Swain J. L., O'Brien T. F. Vacuum blood-culture bottles inhibiting growth of Candida and fostering growth of Bacteroides. Lancet. 1974 Nov 16;2(7890):1174–1176. doi: 10.1016/s0140-6736(74)90813-7. [DOI] [PubMed] [Google Scholar]
- Hall M. M., Mueske C. A., Ilstrup D. M., Washington J. A., 2nd Evaluation of a biphasic medium for blood cultures. J Clin Microbiol. 1979 Nov;10(5):673–676. doi: 10.1128/jcm.10.5.673-676.1979. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Hardy D. J., Hulbert B. B., Migneault P. C. Time to detection of positive BacT/Alert blood cultures and lack of need for routine subculture of 5- to 7-day negative cultures. J Clin Microbiol. 1992 Oct;30(10):2743–2745. doi: 10.1128/jcm.30.10.2743-2745.1992. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Harkness J. L., Hall M., Ilstrup D. M., Washington J. A., 2nd Effects of atmosphere of incubation and of routine subcultures on detection of bacteremia in vacuum blood culture bottles. J Clin Microbiol. 1975 Oct;2(4):296–299. doi: 10.1128/jcm.2.4.296-299.1975. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Hopfer R. L., Moore D. G., Fainstein V., Watkins S., Wenglar M. Routine use of BACTEC 16B bottles to remove antibacterial and antitumor agents from blood cultures of cancer patients. J Clin Microbiol. 1983 Oct;18(4):759–764. doi: 10.1128/jcm.18.4.759-764.1983. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Jessamine P. G., Hoban D. J., Forward K. R. Positive Bactec resin cultures do not influence antimicrobial selection. Diagn Microbiol Infect Dis. 1990 Jul-Aug;13(4):281–284. doi: 10.1016/0732-8893(90)90017-p. [DOI] [PubMed] [Google Scholar]
- Knepper J. G., Anthony B. F. Diminished growth of Pseudomonas aeruginosa in unvented blood-culture bottles. Lancet. 1973 Aug 11;2(7824):285–287. doi: 10.1016/s0140-6736(73)90792-7. [DOI] [PubMed] [Google Scholar]
- Moody J. A., Fasching C. E., Shanholtzer C. J., Gerding D. N., Peterson L. R. Evaluation of new blood culture processing systems. J Clin Microbiol. 1984 Sep;20(3):351–356. doi: 10.1128/jcm.20.3.351-356.1984. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Peterson L. R., Shanholtzer C. J., Mohn M. L., Gerding D. N. Improved recovery of microorganisms from patients receiving antibiotics with the antimicrobial removal device. Am J Clin Pathol. 1983 Nov;80(5):692–696. doi: 10.1093/ajcp/80.5.692. [DOI] [PubMed] [Google Scholar]
- Ringertz S., Eriksson B., Malmborg A. S., Nyström S., Wretlind B. Use of the antimicrobial removal device prior to blood culture in patients on antibiotic therapy. Eur J Clin Microbiol. 1985 Dec;4(6):544–547. doi: 10.1007/BF02013391. [DOI] [PubMed] [Google Scholar]
- Strand C. L. Evaluation of the antimicrobial removal device when used with the BACTEC blood culture system. Am J Clin Pathol. 1982 Dec;78(6):853–856. doi: 10.1093/ajcp/78.6.853. [DOI] [PubMed] [Google Scholar]
- Thorpe T. C., Wilson M. L., Turner J. E., DiGuiseppi J. L., Willert M., Mirrett S., Reller L. B. BacT/Alert: an automated colorimetric microbial detection system. J Clin Microbiol. 1990 Jul;28(7):1608–1612. doi: 10.1128/jcm.28.7.1608-1612.1990. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Weinstein M. P., Mirrett S., Reimer L. G., Wilson M. L., Smith-Elekes S., Chuard C. R., Joho K. L., Reller L. B. Controlled evaluation of BacT/Alert standard aerobic and FAN aerobic blood culture bottles for detection of bacteremia and fungemia. J Clin Microbiol. 1995 Apr;33(4):978–981. doi: 10.1128/jcm.33.4.978-981.1995. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Weinstein M. P., Mirrett S., Wilson M. L., Harrell L. J., Stratton C. W., Reller L. B. Controlled evaluation of BACTEC Plus 26 and Roche Septi-Chek aerobic blood culture bottles. J Clin Microbiol. 1991 May;29(5):879–882. doi: 10.1128/jcm.29.5.879-882.1991. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Weinstein M. P., Mirrett S., Wilson M. L., Reimer L. G., Reller L. B. Controlled evaluation of 5 versus 10 milliliters of blood cultured in aerobic BacT/Alert blood culture bottles. J Clin Microbiol. 1994 Sep;32(9):2103–2106. doi: 10.1128/jcm.32.9.2103-2106.1994. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Weinstein M. P., Reller L. B., Murphy J. R., Lichtenstein K. A. The clinical significance of positive blood cultures: a comprehensive analysis of 500 episodes of bacteremia and fungemia in adults. I. Laboratory and epidemiologic observations. Rev Infect Dis. 1983 Jan-Feb;5(1):35–53. doi: 10.1093/clinids/5.1.35. [DOI] [PubMed] [Google Scholar]
- Wilson M. L., Harrell L. J., Mirrett S., Weinstein M. P., Stratton C. W., Reller L. B. Controlled evaluation of BACTEC PLUS 27 and Roche Septi-Chek anaerobic blood culture bottles. J Clin Microbiol. 1992 Jan;30(1):63–66. doi: 10.1128/jcm.30.1.63-66.1992. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Wilson M. L., Mirrett S., Reller L. B., Weinstein M. P., Reimer L. G. Recovery of clinically important microorganisms from the BacT/Alert blood culture system does not require testing for seven days. Diagn Microbiol Infect Dis. 1993 Jan;16(1):31–34. doi: 10.1016/0732-8893(93)90127-s. [DOI] [PubMed] [Google Scholar]
- Wilson M. L., Weinstein M. P., Reimer L. G., Mirrett S., Reller L. B. Controlled comparison of the BacT/Alert and BACTEC 660/730 nonradiometric blood culture systems. J Clin Microbiol. 1992 Feb;30(2):323–329. doi: 10.1128/jcm.30.2.323-329.1992. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Wright A. J., Thompson R. L., McLimans C. A., Wilson W. R., Washington J. A., 2nd The antimicrobial removal device. A microbiological and clinical evaluation. Am J Clin Pathol. 1982 Aug;78(2):173–177. doi: 10.1093/ajcp/78.2.173. [DOI] [PubMed] [Google Scholar]